12.07.2015 Views

Raypak Hi Delta brochure - California Boiler

Raypak Hi Delta brochure - California Boiler

Raypak Hi Delta brochure - California Boiler

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Boiler</strong>s (Type H)HD101-HD401 302B-902B 992B-2342BWater Heaters (Type WH)H D 1 0 1 - H D 4 0 1 3 0 2 B - 9 0 2 B 9 9 2 B - 2 3 4 2 BA S M E , National Board Registered, 160 PSI H Stamp v v v N/A N/A N/AHLW Stamp N/A N/A N/A v v vHeat Exchanger Tubes Copper v v v v v vCupro Nickel V V V V V VHeaders Bronze V V V v v vCast Iron v v v V V VPressure Relief Valve 30 , 45 , 75 & 150 PSI A va i l a b l e V V V V V V60 & 125 v v v v v vTemperature & Pressure Gauge v v v v v vPump – 120V, Single-Phase V V V V V V120V Power Supply With 120V/24V Transformer v v v v v vPump Time Delay Single Phase v v v v v vDiagnostic Display Central 16-Event Memory N/A v v N/A v vTemperature Controller B-20: On/Off, Mechanical V V V V V VB-28: On/Off, Digital V V V V V VB-6: 2-Stage, Mechanical V V V V V VB-26–B-27: 2-Stage, Digital V V V V V VB-21–B-23: 4-Stage, Digital V V V V V VB-24: 2-Stage, Raytemp (Digital) N/A V V N/A V VB-25: 4-Stage, Raytemp (Digital) V V V V V VY-200 Series, Digital V V V V V VHot Surface Ignition System 3-try v v v v v v1-try N/A V V N/A V V<strong>Hi</strong>gh Gas Pressure Switch V V V V V VLow Gas Pressure Switch V V v V V vB l o c ked Vent and Air Pressure Switches v v v v v v<strong>Hi</strong>gh Limit Switch Manual Reset, Fixed v N/A N/A v N/A N/AManual Reset, Adjustable V v v V v vAutomatic Reset, Adjustable V (1) V V V VLow Water Cut-Off, 24V With manual reset and test button V V V V V VFlow Switch v v v v v vFiring Mode On/Off (H4, WH1) V (2) V v (2) V2-Stage (H3, WH3) v (3) V V (3) V3-Stage (H8, WH8) N/A N/A (4) N/A N/A (4)4-Stage (H9, WH9) N/A N/A (5) N/A N/A (5)4” WC Supply Pressure Natural Gas Only v V (6) v V (6)TruSeal Direct Vent System v V V v V VAir Filter, Room Air v v v v v vAir Filter, Ducted Outside Air v V V v V VEfficiency 84% (Category I) v v v N/A N/A N/A(98% ava i l a b l e ; See Specialty Models) 85% (Category I) N/A N/A N/A v v v(402B - 2002B only) 87% (Category II) N/A V V N/A N/A N/ACombustible Floor Rated v v v v v vAlarm System V V V V V VVent Terminal Outdoor and Through-the-Wall V V V V V VRight-Hand Water Connections V V V V V VCSD-1/GE GAP Control System N/A (7) V N/A (7) VLow NOx Compliance Meets all current requirements v v (8) v v (8)Cold Water Start Cold water protection systems N/A V V N/A V VCold Water Run Cold water protection systems V V V V V VNotes:1 Standard on on/off boilers (H4); Optional on all others2 Standard on Models 302B and 402B; Optional on Models 502B-902B3 Optional on Models 302B and 402B; Standard on Models 502B-902B4 Standard on 992B; Optional on 1262B-2342B5 Not available on Model 992B; Standard on Models 1262B-2342B6 Option but not available on Model 2002B7 Not applicable for Models 302B and 402B; Optional for Models 502B-902B8 Standard on Models 992B-2002B; Models 2072B and 2342Brequire site testing and have different emissions requirements(Consult factory)v v = StandardV V = OptionalR a y p a k , I n c. • 2151 Eastman Ave., Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-9725 • www.raypak.comCat. No. 1100.12D Effective 06-15-10 Replaces: 11-15-09

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!