12.07.2015 Views

Heat Seeker Pool Heat Pump - Poolstore

Heat Seeker Pool Heat Pump - Poolstore

Heat Seeker Pool Heat Pump - Poolstore

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

J. Troubleshooting Your Swimming <strong>Pool</strong> <strong>Heat</strong> <strong>Pump</strong>: Error Codes1. The most common problem reported is the heat pump showing a display but notrunning its fan and compressor. This is the time delay on start up. From pressingSTART/STOP there is a 2 – 3 minute delay before the fan and compressor start.2. The second most common problem is insufficient flow through the heat pump indicatedby EE 03. If your swimming pool filter has a multiport valve turn off the pool pump andturn the valve to “recirculate” , restart the pool pump and try the heat pump again. If thissolves the problem make sure your sand filter is backwashed.3. Another issue is not being able to operate the control panel at all. Look for a smallpadlock symbol on the display which means that the controls are locked. To releasethis press the up and down arrows together at the same time for about 5 seconds sothat the padlock symbol disappears.4. During the operating and defrosting process, the heat pump will yield a volume ofcondensed water. The condensed water from the cooling coil will drip from the bottomof the heat pump. Do not assume the condensed water is due to a fault or a leak in theheat pump.The table below shows error codes the heat pump may displayFault/Error Display Cause ActionWater temperaturein, sensor fault/errorWater temperatureout, sensorfault/errorCoil 1 sensorfault/errorCoil 2 sensorfault/errorAmbient temperaturesensorToo high differenceintemperature in/out.PP 01 Sensor interrupted or short circuited Test line, sensor andsocket.May have to be replacedPP 02 Sensor interrupted or short circuited Test line, sensor andsocket.May have to be replacedPP 03 Sensor interrupted or short circuited Test line, sensor andsocket.May have to be replacedPP 04 Sensor interrupted or short circuited Test line, sensor andsocket.May have to be replacedPP 05 Sensor interrupted or short circuited Test line, sensor andsocket.May have to be replacedPP 06 Water flow too low Check valves, filter pump,filter and by-pass<strong>Heat</strong>ing up PP 07 Water flow too low Check valves, filter pump,filter and by-passFirst frost proofingrunPP 08 Low out temperature Empty system of waterSecond frostproofing runPP 09 Low out temperature Empty system of waterFunction error insystem 1EE 01 Function error in print card Call technicianFunction error insystem 2EE 02 Input voltage too low Check main cable /electricianFlow guard error EE 03 Too small or too high flow Check pool pump, piping,by-pass and ball cocks.Check technical specEE 04Temperature EE 05 Water flow varying Check pool pump andfluctuationspiping. Check valves, filterand by-passDefrosting Logo Cold coil / element. None. Normal functionCommunication error EE 08Communication error betweencontrol panel and controlCheck cable connection.Call technician<strong>Pool</strong> <strong>Heat</strong> <strong>Pump</strong>: Page 9 of 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!