15CA/15BS/35CA ELECTR<strong>IC</strong> STR<strong>IK</strong>ESINSTALLATION INSTRUCTIONS • Please read carefully before attempting installationASSA ABLOY Sicherheitstechnik GmbH • Bildstockstraße 20 • 72458 Albstadt • GERMANYGERMANY: Phone +49 7431 123-0 • Fax +49 7431 123-240 • albstadt@assaabloy.de • www.assaabloy.deUSA: Phone +1 407 483 0031 • Fax +1 407 870 2960 • info-usa@effeff.com • www.effeff.com/usa15BS • DIMENSIONS15CA/35CA • DIMENSIONS5/8"[16.0]1-1/4"[32.0]1/8"[3.0]1-3/32"[27.50]9/16"[14.25]1-1/8"[28.50]1/8"[3.0]1-3/16"[30.50]5-7/8"[149.30]5-3/8"[136.50]1-11/32"[34.0]3-1/2"[89.0]6"[150.0]5-3/8"[136.50]2-11/16"[68.30]1-15/16"[33.50]1-15/32"[37.20]3-17/32"[89.60]3-7/16"[87.40]13/16"[20.50]11/32"[9.10]1-21/32"[41.90]3-7/16"[87.40]2-9/32"[58.0]1-9/16"[39.99]Order number Fail secure Fail safe Monitoring 8-16 V AC/DC 12V DC 24 V DC15AV---37829E31 X X15AV---37829F31 15RRV--37829E31 XX XXX15RRV--37829F31 X XX35AV---37829E91X X35AV---37829F9135RRV--37829E91XX X XX35RRV--37829F91X XXOrder number Fail secure Fail safe Monitoring 8-16 V AC/DC 12V DC 24 V DC15.23--08940R11 15.23--08940E31 15.23--08940F31 XXXXXXNOTE: Drawings are not to scale. All dimensions in inch and mm. This information is subject to change without notice.


INSTALLATIONCAUTION! Before connecting any device at the installation site, verify input voltage and current using a multimeter.Many power supplies and transformers operate at higher levels than listed. Any input voltage exeeding 10% of solenoidrating may cause severe damage to the unit and will void the warranty.GENERAL INFORMATION1. This electric strike may be equipped with a 8 - 16 V AC, 12 V AC/DC or 24 V AC/DC solenoid.INSTALLATION INSTRUCTIONS1. Prepare door jamb per dimension detail.2. Connect wires coming from the low voltage power source(see wiring diagrams and electrical specifications below).3. NOTE: It is important to allow enough space behind the electric strike in the jamb cut-out for the wires.Bunching the wires inside the electric strike body may cause the unit to not operate properly.WIRING DIAGRAMeffeff electric strikes are not polarity sensitive.Connect the wires direct to the terminals.ELECTR<strong>IC</strong>AL SPECIF<strong>IC</strong>ATIONS15CA/15BS/35CACurrenton AC (mA)Currenton DC (mA)R1 8-16V (8V) 350 485R1 8-16V (16V) 700 970E3 12V 125 200F3 24V 70 102E9 12V fail safe 195F9 24V fail safe 105MINIMUM WIRE GAUGEREQUIREMENTS24 V DC 12 V DC200 feet or less 350 485200 - 300 feet 700 970300 - 400 feet 125 200FIVE YEAR LIMITED WARRANTYD0038600 05/05

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!