12.07.2015 Views

DC axial fans 2011 [PDF] - ebm-papst

DC axial fans 2011 [PDF] - ebm-papst

DC axial fans 2011 [PDF] - ebm-papst

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

max. 505 m 3 /h<strong>DC</strong> centrifugal <strong>fans</strong>Series RER 160 NTD 165 Ø x 51 mmInformationNEWNEWNominal dataPa500400300200100[in H 2O]1,61,20,80,42mmR5Air flowAir flow21 nmin0 5050 100Air flowAir flow100 150150 200 250Nominal voltagenmaxCFMm³/hVoltage rangeHighlights:– Control inputs, alarm and speed signals available on request.– 3-phase fan drive with high degree of running smoothness.– High pressure build-up.– Backward curved impeller.General characteristics:– Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate.– Fully integrated electronic commutation.– Direction of air flow: <strong>axial</strong> air intake, centrifugal air exhaust out of the outlet.– Connection via single strands AWG 22, TR 64. Bared and tin-plated.– Mass: 590 g.Sound power levelSintec sleeve bearingsBall bearingsType m 3 /h CFM V<strong>DC</strong> V<strong>DC</strong> Bel(A) / Watts RPM °C Hours Hours P.RER 160-28/14N/2TDA 370 217 24 16...28 7,4 51 4 200 -20...+60 55 000 / 27 500 110 000 2RER 160-28/18N/2TDHHP* 505 297,5 48 36...60 8,5 142 6 000 -20...+65 40 000 / 22 500 80 000 3min.RER 160-28/18 NTD...max.66 18,3The air flow and noise level of <strong>fans</strong> without externalhousing depends on the installation conditions. The statedair flow and noise levels have been measured underthe following conditions:Centrifugal fan mounted on a base plate 260 x 260 mm.Cover plate 260 x 260 mm with an air inlet of Ø 100mm, concentric to the impeller.Pa1000800600400200[in H 2 O]3,2 4,02,41,60,8048 38...57350100100 150 200 250200 300 400N GPower inputNominal speed— 2,0 800CFMm³/hTTemperature rangeIPWMService life L 10 (40 °C)<strong>ebm</strong>-<strong>papst</strong> Standard1+650,3AService life L 10 (T max )<strong>ebm</strong>-<strong>papst</strong> Standard+0,710+425+ 0,1ø58+0,3ø72ø160M4 (4x)6,1HPLife expectancy L 10 Δ(40 °C) see P. 15-20...+70 55 000 / 27 500 110 000Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only.The data specified here are technically feasible benchmark values. The <strong>fans</strong> can be specially adapted to your application with signaloutputs and control inputs.*The specific service life is valid when an external capacitor is wired between the plus and minus strands.Please note the wiring suggestion.max. 8 deepmax. 8 tief+0,5+0,8Curve1Specials99<strong>DC</strong> <strong>axial</strong> <strong>fans</strong>Representatives Accessories AC centrifugal <strong>fans</strong> AC <strong>axial</strong> <strong>fans</strong> ACmaxx / GreenTech ECcompact<strong>DC</strong> <strong>fans</strong> - specials <strong>DC</strong> centrifugal <strong>fans</strong><strong>fans</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!