12.07.2015 Views

Energy Efficiency_Solutions_for_Buildings - GreenProf

Energy Efficiency_Solutions_for_Buildings - GreenProf

Energy Efficiency_Solutions_for_Buildings - GreenProf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Energy</strong> efficiency:tighter regulations,new incentivesToday’s challengesNew regulations now require energy-efficiencymeasures and more energy-efficient equipment<strong>Energy</strong> efficiency is no longer an option. The Kyoto Protocol has spurred governmentsworldwide to pass legislation to ensure smarter energy use in buildings.The European Union, <strong>for</strong> example, made a firm commitment in March 2007 to reduceCO 2emissions by 20% by 2020. Part of a package of measures known as “3x20 by 2020”,the reduction will come with a 20% improvement in energy efficiency and a shift in the EU’senergy mix to include 20% renewable energy.Other countries have adopted a slightly longer timeline and more ambitious targets,aiming <strong>for</strong> a 50% reduction in CO 2emissions by 2050.Reaching these targets will require real change, and governments are stepping up theiref<strong>for</strong>ts to legislate, regulate, and set standards to improve energy efficiency.3 x 2020% reductionin CO 2emissions20% improvementin energy efficiency20% energy fromrenewable resourcesHigh-energy-yieldcontrol systemAdvanced control systemStandard control systemControl system does notgenerate energy savingsNew legislation, new rulesThe new trend toward tighter energy-efficiencylegislation started with the Kyoto Protocol.Laws like the US <strong>Energy</strong> Policy Act and theEuropean Union <strong>Energy</strong> Directive effectively setthe rules <strong>for</strong> our energy future.Public- and private-sector initiatives• EU standard EN 15232This standard is used to estimate the impact ofbuilding automation systems on active energyefficiency, stating potential savings on heatingand electricity according to the type of building.Class AClass BClass CClass D• White certificatesWhite certificates are granted <strong>for</strong> energyefficiencymeasures. Some governmentsrequire all electrical and gas utilities over acertain size to provide proof that they havehelped customers reach a particular level ofenergy savings. Utilities that meet minimumrequirements can then sell their surpluscertificates to other utilities.• LEEDLEED is a green building rating systemdeveloped by the US Green Building Council(USGBC). It provides a suite of standards<strong>for</strong> environmentally-sustainable buildingconstruction and renovation practices.Since its inception in 1998, LEED hasgrown to encompass over 50 US states and30 countries.Financial incentivesMany governments are using financialincentives or market mechanisms to encourageenergy efficiency. These include tax credits,interest-free government loans, partial sales taxexemptions on energy-efficiency equipmentand services, subsidized bank loans, andlocal grants from government agencies andorganizations in the private sector.The new regulations will have an impacton all buildingsAll buildings—both existing and new—and allenergy systems are concerned:> Lighting> Electrical distribution> Heating, ventilation, and air conditioning> Cooling systems67


A commitment to energy savingsAsk any building professional. So-called “passive” energy-efficiencymeasures like insulation or low-energy-consumption equipment are notenough to meet the challenges our energy future has in store.Today, it is a building’s net energy consumption that counts:the difference between energy consumed and energy produced.And, to ensure that the buildings of the future are net energy producers,we must reduce consumption and offset what we do use by producingenergy from renewable sources.We can help you achieve net-producer status, and generate substantialsavings by optimizing the 3 pillars of energy-efficiency:> Reduce consumption by implementing active energy-efficiencysolutions> Produce clean energy from renewable resources> Optimize consumption by using the latest technologiesWe can help you make savings!<strong>Energy</strong> audit& measureA more efficient,smarter, cleanerenergy futurePassive <strong>Energy</strong> <strong>Efficiency</strong>Fix the basicsLow consumption devices,insulation material,power factor correctionActive <strong>Energy</strong> <strong>Efficiency</strong>Optimise throughautomation &regulationHVAC control,lighting control,variable speed drives…Monitor,maintain, improveMeters installation,monitoring services,EE analysis software89


A commitment to energy savingsMeet—and exceed—your customers’expectationsSchneider Electric energy-efficiency solutions provide you with acomprehensive offering designed to meet your customers’ changingneeds and boost your sales. When you sell Schneider Electric energyefficiencysolutions, you add a new environmental dimension to yourtechnical offering, and become your customers’ trusted energyefficiencyexpert.Offer your customers the added value they demand• Innovative solutions with measurable results• Substantial energy savings> Up to 30% energy savings <strong>for</strong> existing buildings> The capacity to contribute to meeting Kyoto targets <strong>for</strong> new buildings> Lower operating costs• Recommendations to help your customers comply with regulationsand increase the value of their property• Measures to enhance your customers’ environmentally-friendly imageand further their Corporate Social Responsibility strategySave energy and stay on budget• Start with measurement solutions <strong>for</strong> quick—often immediate—andmeasurable return on investment• Offer your customers the right solutions <strong>for</strong> their budget:> Without compromising between energy efficiency and budgetrestrictions> By offering innovations at a fixed cost> By promoting incentives <strong>for</strong> which your customers are eligible• Present compelling proof of the expected savings to your customers.Some companies maketheir energy savingstargets public:Nestlé is aiming <strong>for</strong>5% savings per yearfrom 2005 to 2010STMicroelectronicsis targeting 2.5%Be your customers’leading energyefficiencypartnerAchieve significant and sustainablesavings with Schneider ElectricYour energy managerMetering, monitoring, control solutions, and costoptimization servicesYour energy expertConsulting, training, and planning and implementation ofenergy-efficiency solutionsYour green partnerEnvironmentally-friendly and renewable-energy products1213


Our solutionsPower distributionShed non-priority loads automatically 18Correct your installation’s power factor and reduce energy costs 20Reduce power loss by fi ltering harmonics 22Design smart to reduce capital expenditures and operating costs 24Start saving energy by monitoring your MV network locally 26Take advantage of discount MV utility rates without the risk of counterparty power cuts 28Power distributionHVAC controlRegulate kitchen exhaust hood speed according to temperature 32Regulate cooling-tower water temperature and save energy 34Regulate temperature by maintaining air pressure 36Reduce your electrical consumption by controlling your HVAC system’s motors 38HVAC controlLighting controlUse KNX presence and daylight detectors <strong>for</strong> precision lighting control 42Automate lighting control using KNX presence daylight detectors 44Achieve simple lighting control using natural light and building occupation 46Save energy by controlling lighting scenarios <strong>for</strong> different areas of your building 48LightingcontrolRenewable powergeneration<strong>Energy</strong> monitoringMeet essential energy measurement needs with a simple metering solution 52Get essential electrical in<strong>for</strong>mation <strong>for</strong> each area of your building 54View and monitor the energy used by your lighting installation 56Analyze your energy consumption online without a BMS 58Manage WAGES in your small to medium-sized building 60Manage WAGES in non-critical large industrial buildings 62Manage and sub-bill WAGES in large commercial buildings 64Analyze energy data to optimize operation of your industrial buildings 66Buildingmanagement<strong>Energy</strong>monitoringBuilding managementSchedule selected loads simply via your BMS 70Monitor and control electrical loads in your retail shopfront 72Control lighting and heating at room level with a KNX-based system 74Control room lighting, temperature, and blinds automatically 76Manage hotel energy consumption according to guestroom occupancy 78Reduce hotel electrical consumption and improve com<strong>for</strong>t with a full KNX system 80Combine various control systems to achieve maximum savings 82Monitor your building’s power supply and control HVAC, lighting, and blinds 84Boost energy effi ciency and increase the availability of your electrical installation 86Control and monitor HVAC, lighting, security systems, and energy consumption 88Renewable power generationUse available rooftop space to install and operate solar panels 92Boost your “green” image and save photovoltaic energy 94Supply a small group of remote, off-grid buildings with electricity 9614 15


When you target your electrical installation,you have the potential to generate substantialsavings by optimizing the three pillarsof energy efficiency:> Measurement> Optimization of energy consumption> Sustainable per<strong>for</strong>mance <strong>for</strong> lasting resultsThe solutions on the followingpages can help you turn your powerdistribution system into a source ofsavings. These simple, cost-effective solutionsdo not require a Building Management Systemand can help you optimize your installation’s mainfunctions, such as power supply, uninterruptedservice, protection, and energy quality.Additional functions deliver useful in<strong>for</strong>mationto aid in optimizing your installation and energyconsumption.Choose the solution that’s right <strong>for</strong> youPower distribution> Shed non-priority loads automatically (p. 18)> Correct your installation’s power factor and reduce energy costs (p. 20)> Reduce power loss by filtering harmonics (p. 22)> Design smart to reduce capital expenditures and operating costs (p. 24)> Start saving energy by monitoring your MV network locally (p. 26)> Take advantage of discount MV utility rates without the risk of counterpartypower cuts (p. 28)1617


Power distributionApplication: all buildingsShed non-priority loadsautomaticallyI want to switch to a more cost-effective contractwith my electric utility. I can shed non-critical loads tomake sure I stay within my utility rate block, but I can’taf<strong>for</strong>d sudden power cuts.BenefitsMeasure Reduce energy consumption Reduce energy costsCircuit breakerCompact NSX100NReflex load sheddingSDx moduleMicrologic 5.2 Etrip unitSolutionDesign your electrical system aroundCompact NSX circuit breakersCompact NSX circuit breakers allow you to manage reflex loadshedding: the automatic shedding of specific loads.The Compact NSX circuit breaker with integratedMicrologic 5.2 E electronic trip unit sends the reflex loadshedding command. The trip unit measures I, V, P and E, andproduces the appropriate alarms. Each alarm is associated witha load shedding trigger setting and a deactivation setting, eachwith time delay. The reflex load shedding order is sent via theCompact NSX circuit breaker’s SDx output module.PTDTPDDD(t)PT: Pick-up thresholdPD: Pick-up time delayDT: Drop-out thresholdDD: Drop-out time delayEach alarm is associated with a load-shedding trigger settingand a deactivation setting.Alarm: activation zone (in blue)For the user> Save up to 10%off your energy billsSubscribe to a morecost-effective utilitycontract and avoidcostly utility rate-blockoverrun penalties> Get the most outof your investmentand enjoy greaterreliability with theCompact NSX circuitbreaker, integratingboth protectionand measurementcapabilities> Increase poweravailability bypreventing overloadtrippingForprofessionals+ Easy designand use• Limited partnumbers <strong>for</strong> easyselection andordering• No need <strong>for</strong> acurrent trans<strong>for</strong>mer+ Easy installationand maintenance• A single reference<strong>for</strong> the SDx outputmodule• Easy configurationvia user-friendlyRSU* software,your PC and amaintenancemodule—availableon order as part ofthe maintenance kit• Easy testing usingthe LSU* software,your PC, and themaintenance module* Free downloadavailable online at www.schneider-electric.comCircuit breakerC60NPriority loadsCompact NSX 100-630 A circuit breakerThe first-ever mouldedcasecircuit breakerto include protection,measurement, andcommunicationcapabilities in a single unitMicrologic 5.2 E tripunit with integratedenergy measurement—unique on the marketcontactor2PCTNon priority loadsSDx Module with twooutputs and power supplyfrom 24 V to 415 V, ACor DCIndependent,configurable alarmtime delays withflexibility from 1 to 3,000seconds in a single unit18 19


Power distributionApplication: all commercial buildingsCorrect your installation’spower factor and reduceenergy costsBenefitsMeasure Reduce energy consumption Reduce energy costsLV networkCircuit breakerCurrenttrans<strong>for</strong>merI plan to upgrade my electrical installationto meet the new standards. I want to takeadvantage of the opportunity to reduce myelectricity bills and boost the available powerwithout switching to a new utility contract.Forprofessionals+ Easy to install+ 100% factorytested capacitorbankCircuitbreakerCircuit breakerCompact NSXFor the user+ Lifespan ofaround 15 yearsSolutionRegulate power factor automaticallyby using a Varset reactive energycompensatorThe solution automatically regulates power factor correctionaccording to load fluctuations. The resulting power factor, closeto 1, frees up additional available power, allowing you to add onto your installation. The system is built around a Varlogic powerfactor controller, which is also available in a Modbus-basedcommunicating version.Example:With a utility contract <strong>for</strong> 250 kVA with an average power factorof 0.7, penalties are charged <strong>for</strong> consumption over 175 kW(175 ÷ 0.7 = 250 kVA).The Varset system includes a bank of 200 kvar capacitors,which are automatically switched on or off depending onthe power factor detected. A current detector measuresconsumption.The system guarantees a power factor greater than 0.92,regardless of load, raising the actual consumption limit to230 kW (250 x 0.92=230 kW), or 55kW of available energy.> Save up to10% on yourelectricity bills, withROI within two years(actual savings varydepending on localutility penalties)> Increase yourinstallation’savailable power byup to 30%> Eliminateexcessiveconsumption ofreactive energy> Reduce yourcarbon footprint> Boost yourinstallation’sreliability andlifespan by filteringharmonics with theVarset Harmonyrange+ Optionalharmonics filtering+ SlSvar software<strong>for</strong> easy equipmentselection andconfiguration+ CommunicatingModbus versionavailable <strong>for</strong> remotedata transmissionCircuitbreakerVarset• Network voltage: 230 Vto 690 V - 50/60 Hz• Reactive power:7.5 kvar to 1200 kvar• Harmony range:2.7 (135 Hz), 3.8 (190 Hz),4.3 (215 Hz)• Standards:IEC 60439-1, IEC 61921,EN 60439-1• Automatically regulated<strong>for</strong>ced ventilation• With or withoutincoming circuit breakerCapacitor bankVarsetPower factorcorrection viaVarlogic controllersControls reactive powerto obtain the target powerfactor. Provides installationdata and analysisMonitors and providesdata on compensationequipment status• Easy to use• Easy to set up; selfconfigurationavailable• Intuitive user interface• Direct, real-time displayof main measurement• Optionalcommunicating versionavailable (Modbus)20 21


Power distributionApplication: small to medium-sized buildingsReduce power lossby filtering harmonicsI need to reduce the overall harmonicsgenerated by my factory’s variable speed drivesand uninterruptible power supply. My budgetis limited, and the solution has to be simple.BenefitsMeasure Reduce energy consumption Reduce energy costsCircuitbreakerCircuit breakerCompact NSXCircuit breakerMasterpactCurrenttrans<strong>for</strong>merSolutionInstall AccuSine PCS active filtering<strong>for</strong> your electrical installationVariable speed drives and uninterruptible power supplies constitutenon-linear loads. They use a fundamental sine wave (the samefrequency as the network) and generate additional harmonicswaves whose frequencies are multiples of the network’s frequency.The AccuSine PCS active filter constantly generates an equal yetopposite current to the harmonic currents generated by non-linearloads, leaving only the fundamental frequency on the network.The AccuSine PCS is fed from a specific outgoing feeder. It detectsand analyzes the current upline in real time from the non-linearloads and sends out a compensating current via its power line.The following oscillograms illustrate the total current harmonicdistortion (THDI) be<strong>for</strong>e and after the installation of the active filter.For the user> Harmonic filteringreduces power lossin the upline circuitand equipmentby 10%> Ensuresharmonicsof less than 5%> Reducesoverloading andfrees up additionaluseable capacity> Minimizes systemlosses and demandpowerForprofessionals+ Easy to install+ Compensationautomaticallyadjusteddepending on load+ Easy upgradesand add-ons+ Optionalpower factorcorrection possible(recommended byutilities)CircuitbreakerContactorHeadingM3~LightSwitchHarmonicscompensatorsAccuSine PCSM3~CircuitbreakerC60NVariablespeed driveATV31M3~CircuitbreakerCompactNSXVariablespeed driveATV61> Lowers outagerisk> Extendsequipment lifetime> Reduces wireheating (especiallyneutral)AccuSine PCS> A simple line up,including• 50A, 100A and 300Apower ratings UniversalVoltage: 208V - 480V, 3phase 3 wire• NEMA 1, NEMA 12,IP30, IP54 enclosureoptions• Worldwide offer: MeetsUL, CSA, CE, ABS, C-Tick standards> Powerful per<strong>for</strong>mance• Meets all majorworldwide harmonicstandards;IEEE-519, G5/4 -1, GB/T14549, IEC61000-3-2/-3-4• Ultra fast responseto load changes–withinmicroseconds• Cancels all harmonicsfrom 2nd to 50th order• 225% VAR currentinjection to meetinstantaneous loadrequirements and providevoltage support> Expandablecapabilities• Parallel up to 10 unitswith different ratingson one set of currenttrans<strong>for</strong>mers22 23


Power distributionApplication: all types of buildingsDesign smart to reducecapital expendituresand operating costsBenefitsForprofessionals+ Shorten thedesign cycle by upto 40%Measure Reduce energy consumption Reduce energy costsAt the Solution stageView energy dissipationcost, CO 2emissionsand ROI of power factorcorrectionWhen it comes to having an energy-efficientelectrical installation, the most important thingto me is to minimize power losses while keepingcapital expenditures on target.+ Increase qualityby using a singletool <strong>for</strong> the wholedesign process+ Present harddata to back upyour recommendedsolutionSort components by energyconsumption to identify themost efficient choicesUse ID-Spec Large software to designthe ideal electrical installation <strong>for</strong> yourbuilding and your budgetID-Spec Large software offers an array of design capabilitiesunique on the market:• Assess the actual cost savings generated by energy-efficiencysolutions like power factor correction and low loss trans<strong>for</strong>mersFor the user> Reduce capitalexpendituresby 10% by scalingequipment downto optimized usescenarios+ Enhance yourimage as anenvironmentallyconsciousprofessional+ Produce Billof Equipment,reports, andspecifications witha single toolAt the Design stage,use the power barycentertool to:• find out the bestequipment locations in thelayout• define the electricalarchitecture <strong>for</strong> your projectSolution• Reduce wiring lengths and diameters <strong>for</strong> lower materials andinstallation costs• Lower capital expenditures by scaling equipment down tooptimized use scenarios• Calculate the percentage of recyclable wiring and busbartrunking materials• Assess the cost of the electrical system over the entire buildinglifecycleID-Spec Large reports provide compelling data to back up therecommended solutions and can quickly and easily calculate theimpact of alternative solutions.> Lower energyconsumptionby 3% simplyby optimizing yourelectrical equipment> Avoid utilitypenalties throughmore responsivepower consumption> Reduce rawmaterials andinstallation costs byoptimizing wiringlengths and crosssection areaExamples> Food andbeverage plant inJakarta, IndonesiaID-Spec Largedemonstrated thesavings achieved bymoving low voltageswitchboards toalternative locations:• 35% reductionin power loss <strong>for</strong>savings of


Power distributionApplication: any building with a medium voltage networkStart saving energy bymonitoring your MV networklocallyBenefitsRM6 DIDIMeasure Reduce energy consumption Reduce energy costsEasergy Amp21DammeterI am seeking a simple, cost-effective wayto make sure my MV network is functioningproperly so I can take actions to reduce energyconsumption if necessary.ForprofessionalsRM6 IDIRM6 IDISolutionUse a digital ammeter todisplay in<strong>for</strong>mation aboutyour MV networkThe solution is based on a cost-effective digitalammeter installed on the front plate of theswitchboard. The ammeter provides a constantreadout of the MV network’s present andmaximum current. Users can find out the currenton the MV load breaker switches at a glance.Amp 21DL1L2L3For the user> Easy-to-readin<strong>for</strong>mation at MVlevel helps saveenergy by:• Allowing you toidentify unnecessaryloads and takeimmediate correctivemeasures• Telling you whichlines are overloadedso that you canrebalance loadson MV and LVtrans<strong>for</strong>mers> This solutionoffers a number ofbenefits comparedto traditionalanalog ammetersystems:• A single partnumber (digitalammeter withintegrated sensors)<strong>for</strong> easy selection andordering• Enhanced readoutaccuracy, especially<strong>for</strong> small currents• Cost effective+ Easy,engineering-freedesign based ona single product(ammeter withintegrated sensors)+ No trainingneeded+ Easy to install:• For the RM6:ammeter andsensors are factorymounted and tested;nothing to do on site• For the SM6:ammeter is factorymounted and tested;sensors are installedaround the MVcables on site andare designed <strong>for</strong>easy connection tothe ammeter+ Easy rollout:no on-siteconfigurationneededAmp21D ammeter• 4-digit display• Self-poweredbatteryless unit• Measures current on theswitchboard load breakswitch functionRM6 IDIRM6 IDI26 27


Power distributionApplication: any building connected to a MV networkTake advantage of discountMV utility rates without the riskof counterparty power cutsBenefitsForprofessionals+ Factory-tested,preconfigureddesignMeasure Reduce energy consumption Reduce energy costsMain lineVoltage sensorVPIS-VOStart orderVoltage sensorVPIS-VOGTo guarantee the lowest possible utility rates,I have agreed to go off the power grid duringpeak hours. There<strong>for</strong>e, to avoid costly downtime,I need a back-up power supply that kicks inautomatically after just a few seconds.• ATS comes readyto install on an RM6switchboard in aT200I box• The T200Iautomation comespre-programmed,eliminatingsequence errorsduring set-upFaultpassageindicator (FPI)VoltagedetectionVD3H relayVoltagedetectionVD3H relayFaultpassageindicator (FPI)For the user+ More efficientprocurement:easy-to-order basedon existing partnumbersT200ISolutionInstall an Automatic Transfer System(ATS) to switch the MV connectionto a back-up generatorSave energyDepending on your rate agreement, the utility sends out a signaljust be<strong>for</strong>e the higher peak rate kicks in or power is cut off.The ATS receives this signal and:• Starts the generator• Turns on the main switch once the generator is ready• Turns off the generator switchPower is restored in less than 10 seconds.Increase power availabilityATS ensures power availability, per<strong>for</strong>ming the same functions ifvoltage loss is detected on the main electrical line, with powergenerally restored in less than 15 seconds.• The fault passage indicator (FPI) ensures the ATS is locked if afault current is detected to avoid cutting off power to a properlyfunctioningline.> Guarantee lowestpossible utilityratesSavings of 10%are achievable inmany countries—insome countries,when demand is highand supply is short,the price per kWhcan be multiplied bymore than 10> Boost operatingefficiency withautomatic monitoringand guaranteedpower availability—ATS comeswith an optionalcommunicationmodule to transmitin<strong>for</strong>mation to aremote controlsystem+ Quick, easyinstallation• Plug-inconnections only• Kit included <strong>for</strong>mounting T200Ion wall or RM6+ Simplecommissioning:easy to configureservice voltage, timedelays, and ATSoperating modes+ Maintenancefree: automatictesting andtroubleshootingExamples> Users save10% per yearoff standard ratesby opting <strong>for</strong> thenational utility’sspecial peak ratein France, <strong>for</strong>exampleRM6 ring main unit• 24 kV• includes sensors• VPIS-VO VD3H relaysand motorized switchesMUtility ratemanagementSCADAMT200I• Embedded electronics• Includes ATS• Specifically designed<strong>for</strong> the MV network:unlike other solutionson the market, the 10kVinsulation <strong>for</strong> AC supplyprotects the T200 againstover voltages coming fromsubstations28 29


Depending on your business and typeof building, HVAC can account <strong>for</strong> over 40%of energy consumption. You can reduceHVAC energy consumption andsustain optimal consumption levelsby improving the control and management ofventilation, temperatures, and system usage.You can meet today’s demand <strong>for</strong> energyefficiency, occupant com<strong>for</strong>t, and compliance withstandards by implementing one or more of thefollowing solutions:> Install variable speed drives on pumps and fansto adjust energy use to actual need.> Design control architectures that facilitateoperation and interaction of heating, ventilation,air conditioning, and window blinds, zone by zone.> Choose equipment that improves energyquality by eliminating power surges and reducingharmonics.Depending on whether you choose simple, standalonecontrol devices, a comprehensive buildingmanagement system, or a solution somewherein between, you can reduce the amountof energy your HVAC system usesby up to 30%.HVAC controlChoose the solution that’s right <strong>for</strong> you> Regulate kitchen exhaust hood speed according to temperature (p. 32)> Regulate cooling-tower water temperature and save energy (p. 34)> Regulate temperature by maintaining air pressure (p. 36)> Reduce your electrical consumption by controlling your HVAC system’s motors (p. 38)3031


HVAC controlApplication: commercial kitchensRegulate kitchen exhausthood speed accordingto temperatureMy restaurant’s exhaust hood is alwaysrunning at full speed, even when my cookingequipment isn’t being used. I’d like to find a wayto reduce the amount of energy wasted and lowermy utility bills.BenefitsForprofessionals+ Design• Simple andeconomical: the VSDpicks up the signaldirectly from thetemperature sensor• Reducedmaintenance:the VSD can bemounted right onthe fan, eliminatingmaintenanceintensivegearboxes• Easy design andupgradesMeasure Reduce energy consumption Reduce energy costsInstalling a VSD canreduce energy consumption(in grey below) by up to 40%compared to a traditionalstart/stop motor, reducingtotal consumption by about25%.100%Flow50%SavingsSavingsBreakfast Lunch Dinner100% flow with start/stop motor0%6am 7 8 9 10 11 12 1pm 2 3 4 5 6 7 8 9 10 11 12 1am 2 3 4 5SolutionThe solution consists in using variable speed drives (VSD)to adjust exhaust operation to the amount of activity in thekitchen.Fan speed is controlled according to air temperature.A sensor inside the exhaust hood detects air temperature,and an Altivar 12 variable speed drive adjusts the exhaust fanmotor speed.The cooler the air, the slower the fan runs, down to aminimum ventilation level. The exhaust hood is automaticallyturned up or down to meet actual needs, resulting insubstantial savings.An optical smoke sensor can be added to boost thesystem’s regulation capabilities. This configuration requiresan additional control system.For the user> <strong>Energy</strong>savings of20% to 50%,depending on use:maximum exhausthood operation isusually limited to justa few hours a day> Fast ROI,usually within 18 to24 months> Quieter operation• Lowering fan speedby 20% reducesnoise by 20%• Reducing speedby half virtuallyeliminates noise> Lowermaintenance costs+ Installation• Complies withinternationalstandards• Integrated EMCfilter• Simple, beltlesssystem• Easy installationthanks to plug-andplaydesignProjects> United States:VSDs were installedon 12 exhausthoods at a universitykitchen.A VSD controlsthe speed ofeach exhaustfan via smokeand temperaturesensors. Thesystem is expectedto generateannual savings of126,244 kWh.The Altivar 12Variable speed drive<strong>for</strong> small machines andapplications with threephase240 V asynchronousmotor 0.18 to 0.75 kW,120 V single-phase powersupply 0.18 to 2.2 kW,240 V single-phase powersupply 0.18 to 4 kW, 240 Vthree-phase power supplyθ• Can be configured in itspackaging• Quick start optionrequiring no adjustmentIntuitive navigation• Even more compact• Category 1 EMC filter• Local control on thefront panel• Modbus serial link• Resistant to harshoperating environments• Integration of Standard(U/f),• Per<strong>for</strong>mance (sensorlessflux vector control, orSVC) and Pump/Fan(quadratic profile Kn”)control profilesVariablespeed driveATV12• High dynamicper<strong>for</strong>mance onacceleration as well ason braking• Excellent speedregulation on machineload surges32 33


HVAC controlApplication: medium-sized to large buildings with cooling towerRegulate cooling-towerwater temperatureand save energyBenefitsMeasure Reduce energy consumption Reduce energy costsCircuit breakerCompact NSXMy cooling tower is a constant concern.Maintenance needs vary widely depending on theseason, and the installation uses too much energy.I want a solution that will improve yield and reducecosts.Use speed drives to regulate thetower’s fan and pumpFor the userForprofessionals+ Simplermechanics (nobrakes, sensors, orrotation inverters)Cooling towerAir outFanBus controlATV21Variablespeed driveCircuitbreaker C60ContactorLC1DSolutionThe best way to control air-water exchange in a cooling tower isto use variable speed drives to control the tower’s fan and pump,eliminating additional maintenance-hungry mechanical systemswhile meeting the tower’s needs. A PLC regulates fan airflow andpump volume via the variable speed drives.This solution uses up to 50% less energy than direct-startfans and pumps and eases maintenance.Over a given season, the fan and pump motors must operateat full speed just 2% to 5% of the time—the rest of the timethis energy is wasted. Direct-start motors require additionalmechanical systems to solve problems like fan blade rotation dueto wind, or additional resistance due to freezing.This solution uses 20% less energy than two-speed motorsand also improves maintenance.While two-speed motors offer a partial solution to energyconsumption issues, they do nothing to resolve maintenance issues.100%90%Direct-start motor> Reduce energyconsumption> Improve yieldby regulating watertemperature> Lowermaintenancerequirements,especially in extremeweather> Quieter operation> Low harmonics:THDI < 30%> Eliminates inrushcurrent due tomotor start-up+ Facilitates motorsizing (over-speedand standby modesavailable)+ Enhancedprocess regulation+ Extends lifetimeof mechanicalcomponents+ FacilitatesmaintenanceplanningAir inFrom chillerTo chillerSpray nozzlesMake upwaterPumpPercent power required80%70%60%50%40%30%20%10%0% 10%20% 30% 40% 50% 60% 70% 80% 90% 100%Percent fan speedTwo-speed motorATV21 variable speed driveATV21 speed driveRange dedicatedto building HVACapplications.All essential functions <strong>for</strong>variable torque pumpsand fans applications:• 3-phases 200/240 V,380/480 V• UL Type 1/IP20 andIP54 up to 75 kW• Speed range: 1:50• Overload : 110% - 60 s• Integrated EMC filtersclass A or B• Main communicationbus used on the buildingmarket: LonWorks,Metasys N2, BACnet, andApologe FLN.• Con<strong>for</strong>mity to theinternational standardsand certifications : CE,UL, CSA, C-Tick...• “Reduced-Capacitance”technology: immediatelyoperational and withoutharmful effect, harmonicstreatment without addedartifices: THDI < 30%34 35


HVAC ControlApplication: all buildingsRegulate temperatureby maintaining air pressureIt is difficult to make heating and airconditioning systems more energy efficientwithout affecting occupant com<strong>for</strong>t. The fact thatHVAC systems are often set up by floor furthercomplicates the situation. I need a flexible solutionthat can adapt to fluctuating occupancy whileusing only the amount of energy that is actuallyneeded.SolutionUse variable speed drives to regulateair pressure and temperatureTake a chilled-beam heating system, <strong>for</strong> example. The mostenergy-efficient solution <strong>for</strong> this type of heating system would beto add temperature regulation functions via a thermostat, pluspressure regulation in the beam and the room.The thermostat (T) (see diagram opposite) controls air flow byadjusting the shutters on the intake vent (1). The pressure in theheated beam (2) and the room (3) are kept at constant levels byvarying fan speed. The two ATV21 variable speed drives featurean integrated proportional regulation function that allows them tocontrol the fans directly based on in<strong>for</strong>mation from the pressuresensors (P).The solution optimizes regulation regardless of fluctuatingoccupancy patterns. To fine tune energy consumption evenfurther using presence detectors, automatic blind controllers,and timers, a building management system would be required.In this type of setup, the variable speed drives and sensorswould be connected to the BMS via a communication bus.BenefitsFor the user> Save up to20% off yourenergy costs byusing independentvariable speed drives> Minimizemaintenance andfilter clogging> Quieter operation> Use up to 50%less energy byintegrating variablespeed drives intoyour buildingmanagement system(BMS)> Regulatetemperature withina limited range> Provide constantventilation> Add presencedetectors andautomationsystems to furtheroptimize the systemForprofessionals+ Design• Eliminates directstarts, so motor sizecan be decreased• Simplifies electricalarchitecture asall functions areintegrated into thevariable speed drive• Eliminates theneed <strong>for</strong> additionalanti-harmonics filters• Includes integratedcommunication bus+ Installation• Products arecompact in size• Optional featurescan be addedwithout increasingproduct size• Simple userinterface+ Maintenance• Local or remotetroubleshooting• Smootherstarting increasesthe lifespanof mechanicalcomponents andreduces frequencyof maintenanceMeasure Reduce energy consumption Reduce energy costsRoomP12The Altivar 21variable speeddrive is designedspecifically <strong>for</strong>building systemsPT3• Low harmonics (THDI< 30%) thanks to C-lesstechnology (with reducedDC bus capacitors)• Optional versionswith integrated EMC(electromagneticcompatibility) filtersCircuitbreaker C60ContactorLC1DCircuit breakerCompact NSXATV21Variablespeed drive• Modbus standard on allmodels• LonWorks, Metasys N2,Apogee FLN, and BACnetavailable as options36 37


HVAC controlApplication: medium to large size buildingsReduce your electricalconsumption by controllingyour HVAC system’s motorsBenefitsForprofessionals+ Design• Simple, innovativesolutionMeasure Reduce energy consumption Reduce energy costsI want to reduce the amount of electricity myHVAC system uses by installing the most relevantcontrol devices.• TeSys U: fewerpart numbers dueto modular basewith plug-andplayoptions <strong>for</strong>easy preparation,selection, andorderingSolutionInstall TeSys U starter-controllersto protect and control constant-loadmotors and ATV variable speeddrives to control variable-load motorsDesigned <strong>for</strong> constant loads, TeSys U intelligent startercontrollersoffer control, protection, and measurementfunctions. When you install TeSys U units, you generate indirectsavings by detecting abnormal operation and taking theappropriate corrective measures, and direct savings throughlower consumption of the control and protection equipment.TeSys U electronics are designed to cut consumption four-foldas compared to traditional electro-mechanical solutions.TeSys U offers protection while constantly measuring motorcurrent so that the following in<strong>for</strong>mation can be transmittedvia the communication module (Modbus, CanOpen, Profibus,DeviceNet, AsI, or Advantys STB) or by direct display via themultifunction control unit:• Operating faults, so that corrective measures can be takenquickly• Overheating, to avoid breakdownsDesigned <strong>for</strong> variable loads, ATV variable speed drives ensurethat consumption is scaled to match motor needs at all times.Variable speed drives generate significant direct savings overdirect-start motors.For the user> Reduce electricalconsumptionby 20% <strong>for</strong>variable loads> Reduce electricalconsumption ofthe protection andcontrol systemby 75% <strong>for</strong>constant loads> Save up to20% spacedue to TeSys Ucompact unit size> Lower theamount of heatgenerated byTeSys U motorstart-up by up to75%, reducingthe need <strong>for</strong>cooling fans in theenclosure> ROI in undertwo years+ Installation• Easy upgrades:during installation,each motor can beadjusted to nominalspeed; TeSys U canbe easily customizedwithout tools orwiring• Save time: withTeSys U there isno need <strong>for</strong> wiringbetween thecontactor and thecircuit breaker; it iseasy to integrate intothe HVAC systemvia RJ45 Modbusconnectors+ Maintenance• Plug-and-playmakes changingthe control unitfaster and easier,minimizing downtime• Access motorsettings (heat,overloads,breakdown log) at alltimes to better avoidbreakdowns• TeSys U: highlymodular designreduces spare partsstock tenfoldTeSys Ustarter-controllerTeSys U offers acapacity of up to32A/15 kW, andconsists of• One 45 mm powerbase:- Two ratings, reversing ornon-reversing- Circuit-breaker function- Built-in interferencesuppression• One of a choice of threeclip-on units:- Standard CU <strong>for</strong>protection againstoverloads and shortcircuits- Expandable CUplus alarm and faultdifferentiation- Multifunction CU <strong>for</strong>real-time control of motorload, local or remotetroubleshooting, andsettingsBus• One of a choice ofthree automation controlmodules:- Modbus, CanOpen,AS-Interface- Profibus DP, Ethernet,DeviceNet, Fipio,Interbus S via AdvantysSTB- Simple parallel link• Two optional 45-mmpower functions:- Limiter-isolator- Changeover relayATV21Variablespeed drive38 39


Lighting control is one of theeasiest ways to save on energycosts.The right lighting control solution slashyour lighting costs by 50% comparedto traditional systems.Our lighting control solutions are flexibleand designed to ensure occupant com<strong>for</strong>t.From small, local devices like timers andoccupancy sensors to sophisticatedcustomized solutions based on KNXstandards, there is a solution to meetyour building’s needs and your budget.Lighting controlChoose the solution that’s right <strong>for</strong> you> Use KNX presence and daylight detectors <strong>for</strong> precision lighting control (p. 42)> Automate lighting control using KNX presence and daylight detectors (p. 44)> Achieve simple lighting control using natural light +and building occupation (p. 46)> Save energy by controlling lighting scenarios <strong>for</strong> different areas of your building (p. 48)4041


Lighting controlApplication: all commercial buildingsUse KNX presenceand daylight detectors<strong>for</strong> precision lighting controlBenefitsMeasure Reduce energy consumption Reduce energy costsKNXARGUS PresenceKNXpush-buttonKNXARGUS PresenceKNXpush-buttonIR-remotecontrolDistance 2010I want to cut energy use substantially inthe main areas of my office building. I also wantthe flexibility to expand and reconfigure the systemas needed, without having to rewire.SolutionUse KNX open bus technologyto link presence detectors toswitching and dimming actuators<strong>for</strong> flexible, expandable automaticlighting controlThe solution entails using presence detectors to activateartificial lighting if and when natural light is below a presetlevel. Lights are automatically switched off when areasare unoccupied or when there is sufficient natural light.Push-button or remote controls can be used to setbrightness levels (100, 300, or 500 lux, or always off,<strong>for</strong> instance) and predefined scenarios.For the user> Use up to 35%less energy bytailoring consumptionto occupationpatterns (based onreference buildingsstated in DIN V18599resp.EN 15232)> Reduceinstallationlabour and costs(compared to atraditional systemwith the samecapabilities)Forprofessionals+ Increasedflexibility• Easy to reconfigureand expand• Settings can beadjusted at any timeand the systemexpanded withoutcostly demolition orrewiring• All devices areconnected to acommon bus line+ New businessopportunitiesSystem componentKNXPowersupplyLighting controlKNXUniversaldimmingactuatortrans<strong>for</strong>merLighting <strong>for</strong> Entrance, Exhibitionand Conference Room230 Volt12 VLighting controlPresence control Manual controlPresence control Manual control KNXKNXControl-unit0-10 V0-10 V0-10 V0-10 VballastLighting <strong>for</strong> Offices and FloorFluorescent> Flexible local orcentralized switchingand on/off indicatorsProject> A Paris bankbranch office(Caisse d’EpargneRéaumur) tookadvantage of arenovation to equipthree 1,500 squaremeter floors with thesystem• KNX solutionsare implementedby skilled electriciansor integrators• They offer a broadrange of user-friendlyand cost-effectivefunctionsComplies withstandards• KNX ISO IEC 14543• EN50090 standardSystemprogrammable via asimple PC using ETSsoftwareKNX ARGUS> Presence detector• Angle of detection: 360°• Range: a radius of max.7 m (at a mounting heightof 2.50 m)• Number of levels: 6• Number of zones:136 with 544 switchingsegments• Number of movementsensors: 4, separatelyadjustable> Light sensor• Internal light sensorinfinitely adjustable fromapprox. 10 to 2000 Lux(ETS)• External light sensor viaKNXKNX Universaldimming actuatorAC 230 V, 50-60 Hz: <strong>for</strong>switching and/or dimmingincandescent lampsor LV halogen lampsusing dimmable woundtrans<strong>for</strong>mers or electronictrans<strong>for</strong>mers42 43


Lighting controlApplication: all buildingsAutomate lighting controlusing KNX presence anddaylight detectorsI want to save energy by automatingmy school’s classroom lighting. The systemalso needs to be flexible and easy to expandand upgrade.SolutionControl room lightingautomatically according tooccupation and natural lightThe solution is built around presence detectors linked toswitching actuators, and features a push-button control<strong>for</strong> use in manual mode. The entire system is connectedvia KNX open bus to facilitate extensions and upgrades.Thanks to the presence detectors, lights are automaticallyswitched on when a person enters the room if naturallight is below a preset level. Lights are automaticallyswitched off when no movement is detected in the roomand the preset time delay has passed.In manual mode, lights can be switched permanently onor off. Switching the system on in manual mode restartsautomatic presence and natural light detection mode.BenefitsFor the user> Use up to 20%less energy byaligning lightinguse with roomoccupation (basedon DIN V18599 orEN 15232 referencebuildings)> Reduceinstallation costsand time comparedto conventionalsystems with similarfunctions> Enhanceoccupant com<strong>for</strong>tForprofessionals+ Flexible <strong>for</strong> easyupgrades andextensions• All functions maybe set and extendedat any time withoutcostly building work• All devices areconnected to acommon bus line+ A source ofnew businessopportunities• KNX solutionsmust be installed byskilled electricians orintegrators and offermany user-friendlyand cost-efficientfunctions+ Lower, morepredictablemaintenance costs• Automatedswitching cuts downon lighting use,extending the lifetimeof light fixtures• Replacementscheduling isfacilitated becausethe number of hoursof use is knownin advance whenoptional switchactuators withcurrent detectionare usedMeasure Reduce energy consumption Reduce energy costsSystem componentKNX ARGUS180/2.20 m flushmountedpresencedetectorKNXPowersupply• Angle of detection: 180°• Range: 8 m right/left,12 m to the front• Mounting height: 2.2 mor 1.1 m with half therangeKNXpush-button1-gang plus• Number of levels: 6• Number of zones: 46• Number of movementsensors: 2, sectororiented,adjustable• Sensitivity: infinitelyadjustable (ETS orpotentiometer)• Light sensor: infinitelyadjustable from approx.10 Lux to 2000 Lux (ETSor potentiometer)• Time: adjustable insteps from 1 s to 8 min(potentiometer) oradjustable from 1 s to255 hours (ETS)Lighting controlKNXSwitch actuator REG-K/2x230/16with manual modeKNXPresence detectorARGUS 180/2.20 mflush-mountedManual control Presence detection KNXKNX switch actuator• Capable of switchingtwo loads independently• Integrated bus couplerand screw terminals• For installation onEN 50022 DIN rails• 230 V switch outputcan be operated with amanual switch• Time delay <strong>for</strong> eachswitch output• Nominal voltage: AC230 V, 50-60 Hz• For each switchingcontact:- Nominal current: 16 A,cosϕ = 0.6- Incandescent lamps:230 V AC, max. 3600 W- Halogen lamps: 230 VAC, max. 2500 W- Fluorescent lamps:230 V AC, max. 2500 VA- Capacitive load: 230 VAC, 16 A, max. 200 µF• Device width: 2.5modules = 45 mm• Contents: busconnecting terminal andcable cover44 45


Lighting controlApplication: any building without a Building Management Systemand with good natural lightAchieve simple lightingcontrol using natural lightand building occupationI want to reduce the amount of energy usedby my building’s lighting by taking advantageof natural light in corridors and areas with largewindows. Most importantly, I want to keep lightsfrom being left on all weekend!BenefitsForprofessionals+ Design• Fully-configurable<strong>for</strong> a variety ofbuilding occupationsituations+ Installation• Offer the addedvalue of automation• Impulse relays workwith standard wiring+ Maintenance• Easy-to-maintaintraditionalarchitectureLNMeasure Reduce energy consumption Reduce energy costsDPNCBTwilightswitchIC 2000Programmablecontroller ZelioInterfacerelayRBNOnDPNCBOffImpulserelayTLCOnDPNCBOffImpulserelayTLCSolutionA controller is programmed with each area’s occupationpatterns. A light sensor allows the lights to be switchedon, via the controller, when natural light levels are toolow. The system is flexible enough to allow occupantsto override the restriction, switching lights on <strong>for</strong> shortperiods of time as needed.Each area is outfitted with the usual light fixtures andpush-button on/off switches, and is powered by anelectrical circuit controlled by an impulse relay thatreceives commands from a controller. The controller alsoincludes digital inputs from one or more twilight switchesthat constantly measure natural light levels.Depending on the configuration, the controller can eitherautomatically switch lights on in a given area, dependingon time of day, or periodically send lights-off commandswhen natural light is high, or when the programmedoccupation time is over. Flexible programming ensuresan optimal balance between energy savings and usercom<strong>for</strong>t.For the user> Save 10% offlighting costs, oneof the top threesources of electricalconsumption> Easy-to-control,independent systemdoes not affect otherbuilding systemsHow it works• Corridor lighting isswitched on whenemployees begin toarrive at 7.30 am.• There is enoughnatural light <strong>for</strong>people to use thearea com<strong>for</strong>tably,so the lights remainswitched off until5.41 pm, when thenatural light is nolonger sufficient.• In the meantime,Mr Smith switches onthe lights in his officewhen he arrives.A short time later, at8.50 am, the lightsare switched offautomatically due togood natural light.Mr Smith switchesthem on again toper<strong>for</strong>m a task at hisdesk, and the lightsremain on <strong>for</strong> 15minutes.• From 4.55 pm on,when natural light islower, Mr Smith canagain leave the lightson as long as hewants.• At 7 pm, theautomatic shut-offkicks in again.Zelio Logic smartrelay is designed <strong>for</strong>use in small automatedsystems• The number of inputs/outputs can be:- 12 or 20 I/O, suppliedwith a 24 V or c 12 V,- 10, 12 or 20 I/O,supplied with a 100 to240 V or c 24 Vwith clock Programminglanguage• To improve per<strong>for</strong>manceand flexibility, ZelioLogic modular smartrelays can be fitted withcommunication modulesand I/O extensionmodules to obtain amaximum of 40 I/O• Programming can beper<strong>for</strong>med:independently, usingthe buttons on the ZelioLogic smart relay (ladderlanguage), on a PC using“Zelio Soft 2” softwareLocalpush buttonRBN Interface:between low voltageand extra low voltage• Enhanced isolationbetween circuits (4KV)• Mini 5mA 5V CA/CC tomaxi 2A 250V CA• Standard IEC 255-100,IEC 529IC 2000 Twilightswitch• Adjustable from 2 lux to2000 lux• Supplied with wallmountedIP54 light sensorcellLocalpush buttonTLC impulse relaywith centralizedcontrol46 47


Lighting controlApplication: all commercial buildingsSave energy by controllinglighting scenarios <strong>for</strong> differentareas of your buildingBenefitsMeasure Reduce energy consumption Reduce energy costsKNXpush-buttonSystem component Lighting control Lighting controlKNXpush-buttonLighting controlIR-remotecontrolDistance 2010Lighting controlManual controlManual controlKNXI want an easy way to manage differentlighting scenarios in different areas of my buildingand save energy.KNXPower supplyKNXSwitch actuatorKNXUniversal dimmingactuatorKNXUniversal dimmingactuatorKNXControl-unit0-10 VSolutionImplement remote or manualcontrols to automaticallymanage different lightingscenariosThis solution uses KNX network technology to linkpush-button controls with switching and dimmingactuators. Different lighting scenarios configuredaccording to occupancy and use can be activatedvia KNX push-button controls. Individual KNX actuatorsmay be used to switch or dim lights manually at anytime. A remote control provides added practicality.For the user> Use up to 10%less energy thanwith a traditionalinstallation <strong>for</strong> asimilar-sized room> Improveoccupant com<strong>for</strong>tand roomambiance> Control bylighting groupseliminatesunnecessary useForprofessionals+ Maximumflexibility, makingadjustments tolayout much easierthan with traditionalsystems+ Requiresworking with askilled electricianor planner/integrator to getmaximum userfriendlinessandcost-effectiveness4-gang plus pushbuttoncontrol withIR receiverPush-button control with8 operating buttons,operating and statusdisplay, and labelling field.The operating displaycan also be used asan orientation light.All functions can becontrolled via IR remotecontrol. The push-buttonis pre-programmed<strong>for</strong> operation with aballast/trans<strong>for</strong>merSchneider Electric IRremote control. Manyother IR remote controls(e.g. existing TV or CDplayer remote controls)can be programmed towork with the unit.trans<strong>for</strong>merKNX software functions:switching, toggling,dimming (single/dualsurface),blind (single/dual-surface), pulse edgetrigger 1-, 2-, 4- or 8-bittelegrams (distinctionbetween short and longoperation), pulse edgewith 2- byte telegrams(distinction between shortand long operation), 8-bitlinear regulator, sceneretrieval, scene saving,disable functions.trans<strong>for</strong>merKNX switch actuatorFor independent switchingof four loads. Withintegrated bus couplerand two screw terminals.For installation on EN50022 DIN rails. The 230V switch output can beoperated with a manualswitch.• Nominal voltage: AC230 V, 50-60 Hz• For each switchingcontact:- Nominal current: 16 A,cosϕ = 0.6- Incandescent lamps:230 V AC, max. 3600 W- Halogen lamps: 230 VAC, max. 2500 W- Fluorescent lamps:230 V AC, max. 2500 VA0-10 V0-10 V0-10 Vballast- Capacitive load: 230 VAC, 16 A, max. 200 µF• Device width: 4 modules= approx. 72 mm• Contents: with busconnecting terminal andcable cover48 49


Measuring energy consumptionis one of the keys to understandinghow your building works so you canbetter exploit potential opportunities <strong>for</strong>savings.This section presents two types of simplesolutions:> Measuring electrical consumption directlyon your installation’s different devices> Measuring and transmitting consumptiondata to a PC or Web server <strong>for</strong> analysisBoth types of solutions can be implementedwithout an automated data managementand analysis system.Choose the solution that’s right <strong>for</strong> you<strong>Energy</strong> monitoring> Meet essential energy measurement needs with a simple metering solution (p. 52)> Get essential electrical in<strong>for</strong>mation <strong>for</strong> each area of your building (p. 54)> View and monitor the energy used by your lighting installation (p. 56)> Analyze your energy consumption online without a BMS (p. 58)> Manage WAGES in your small to medium-sized building (p. 60)> Manage WAGES in non-critical large industrial buildings (p. 62)> Manage and sub-bill WAGES in large commercial buildings (p. 64)> Analyze energy data to optimize operation of your industrial buildings (p. 66)5051


<strong>Energy</strong> monitoringApplication: small commercial and industrial buildingsMeet essential energymeasurement needs witha simple metering solutionBenefitsCircuitbreakerC60Measure Reduce energy consumption Reduce energy costsCircuitbreakerC60CircuitbreakerC60CircuitbreakerC60CircuitbreakerC60I need a basic energy measurement systemthat allows me to identify areas where correctiveactions could help decrease my building’s energyusage.Forprofessionals+ Easy to install,even in existingbuildingsKilowatt-hourmeterME4zrtKilowatt-hour Kilowatt-hour Kilowatt-hour Kilowatt-hourmetermetermetermeterME3zr ME1zr ME1zr EN40SolutionInstall digital kilowatt-hour meterson selected loadsThe solution is based on simple digital kilowatt-hour metersto track energy consumption. Users simply read consumptionin<strong>for</strong>mation directly from the meters’ displays to identify theleading sources of overconsumption <strong>for</strong> each area of thebuilding.These cost-effective pulse meters are designed <strong>for</strong>sub-metering of active energy consumed by a single phase orthree-phase electric circuit with or without distributed neutral.Direct measurement up to 40/63 A is possible. Above 63A,a current trans<strong>for</strong>mer must be used. The meters can beconnected to a PC or PLC <strong>for</strong> analysis and reporting.For the user> Metering canreduce energyconsumption byup to 10%by raising users’awareness ofconsumption habits> Easiest wayto start trackingconsumption> Can be used <strong>for</strong>sub-billing and costallocation+ Easy to wire: nocurrent trans<strong>for</strong>merto install+ Small size <strong>for</strong>easy installationon compactswitchboards+ Remotemeasurementpossible+ The bottombottomconnectionof currentinputs facilitatesconnection tocircuit breakers+ A pulse outputcan be used tomanage a set ofmeters remotelyCafeteriaRefrigeratedroomME range> ME watt-hour metersare designed <strong>for</strong> singlephaseor three-phasecircuits, with or without adistributed neutral• Direct measurement upto 40/63A, up to 6000Awith current trans<strong>for</strong>mer• DIN rail mounting• 5 to 7 digit display• Possible remote transferby NO contact• Complies with:IEC 62053-21 andIEC 61557-12 standardsEN range> EN40 / EN’clickilowatt-hour metersmeasure the activeenergy consumed by asingle-phase circuit> Complies withIEC 61557-12,IEC 62053-21(class 1)52 53


<strong>Energy</strong> monitoringApplication: small to medium-sized buildingsGet essential electricalin<strong>for</strong>mation <strong>for</strong> each areaof your buildingBenefitsMeasure Reduce energy consumption Reduce energy costsPowerViewSoftwareAs facility management contractor, I needa system that can gather, track, and clearlydisplay electrical in<strong>for</strong>mation <strong>for</strong> different areasof my building.EthernetTCPIPForprofessionalsMod/busRS485SolutionInstall meters to send in<strong>for</strong>mationto a PC equipped with PowerViewconsumption-tracking softwarePowerView software is one of the easiest ways to improvea building’s energy efficiency. It is also the perfect foundation<strong>for</strong> upgrading to more sophisticated systems later on.The easy-to-use interface displays measurements andthe associated curves in real time. Both PM9c and moreadvanced PM710 meters use a RS485 Modbus protocol.An EGX100 gateway converts Modbus into Ethernet TCP IPprotocol.For the user> Savings of upto 10% with ROIwithin the first year> Individualmetering raisesoccupants’awareness ofconsumption• Power is switchedoff immediately tounoccupied areas tokeep consumptionon track• Power factor isadjusted to ensureoptimal efficiency andreduce power-factorrelatedpenalties+ Installation• Available as apower-meters-plussoftwarebundle• PowerViewsoftware is easy touse• PM9c, PM710and EGX100meters suitable <strong>for</strong>LV switchboardinstallation• DIN-rail-mountedPM9c and EGX100suitable <strong>for</strong>renovation projects• PM710 meterssame size as oldanalog ammeters orvoltmeters <strong>for</strong> doormounting• Factory-calibratedPM9c meters leavejust a few settings tobe selected on site+ Maintenance• Automaticidentification ofany new SchneiderElectric meterinstalled, <strong>for</strong> fast andeasy upgradesEGX100gatewayPowerView software• Allows up to 32 meters• Delivers data inspreadsheet <strong>for</strong>mat atpre-determined intervalsPM710power meterPM9c and PM710meters• Integrated displays withlocal in<strong>for</strong>mation useful <strong>for</strong>maintenance• PM9c meters measure:real-time and maximumcurrent, voltage, realpower, apparent power,real energy, neutralcurrent, reactive energy,and demand readings• Auxiliary power is220V ACPM9Cpower meterPM9Cpower meterPM9Cpower meter• PM710 meters takethe same measurementsas the PM9c plus demandreactive power, demandcurrent, apparent energy,voltage and currentharmonics• Unlike most othermeters on the market,the PM9c and PM710meet EN61557-12 costallocationstandards54 55


<strong>Energy</strong> monitoringApplication: small retail buildingsView and monitor theenergy used by yourlighting installationBenefitsMeasure Reduce energy consumption Reduce energy costsSystem componentKNXPower supplyVisualizationIP Touch-panel 10"Data loggingKNXBinary inputKNXI want to get an overview of the differentloads in my retail space so that I can identify areas<strong>for</strong> potential savings.L1L2L3N24V=Low voltagePower supplyForprofessionalsCircuitbreakerEN40PElectricity meterCircuitbreakerEN40PElectricity meterCircuitbreakerEN40PElectricity meterSolutionInstall a KNX system to meterand monitor the different loadsin your buildingThe solution is based on EN40p electric meters atthe electrical distribution level.For each KWh used, a given number of pulses aresent from the meter to the KNX binary input.Consumption data is then transferred to the 10” IPtouch panel, where it can be viewed and processed.The touch panel can also be used to view and controlcurrent building states and functions.For the user> Reduce energyconsumption byup to 10%and more: monitoringenergy use enablesyou to identify wasteand encourage moreenergy-effi cientbehaviour> Increase safetyby automating alarmsand emergency calls> Enjoy theconvenience ofremote monitoringand control> Lower installationcosts than traditionalsystems with similarfunctions+ Flexible, <strong>for</strong>easy add-ons andmodifications:all equipment isconnected viaa common busline allowing youto reconfigureor expand theinstallation withoutcostly building work+ Newopportunities <strong>for</strong>your business:KNX solutions mustbe implemented byskilled electriciansor integrators andoffer an array ofuser-friendly, costeffectivefunctionsThe 10”KNXinteractive touchpanel is used to displayand control buildingstates and functions. Itcomes pre-installed withWindows CE <strong>for</strong> fast, easydata management, web,client/server, and networkconfiguration.load• KNX softwareconfiguration via TP VISU• Display size: 10.4”(24.4 cm)• Resolution: 800 x 600pixels, SVGA• Display type: TFT,resistive touch• Colours shown:> 65,000• Mains voltage: DC 24 V• Power consumption:< 20 W• RAM: 128 MBloadEN40p kilowatt-hourmeters• Single-phase kilowatthourmeter with remotetransfer of meteringimpulses (static output)• Compliance withstandard IEC 61557-12,IEC 62053-21(class 1),EN50470-3• Provides directmeasurement up to 40Awithout CT’s, an auxiliarypower supply <strong>for</strong> evengreater savings in term ofwiringload56 57


<strong>Energy</strong> monitoringApplication: any existing commercial buildingAnalyze your energyconsumption onlinewithout a BMS**Building Management SystemBenefitsMeasure Reduce energy consumption Reduce energy costsEthernet NetworkLV NetworkSchneider ElectricEVO serviceI want to get an accurate view of when lightsand other equipment are in use in my building,but I don’t want to invest in a BuildingManagement System.CM3000SolutionOpen an <strong>Energy</strong>View Online account<strong>for</strong> one-stop web-based access toyour building’s energy in<strong>for</strong>mation<strong>Energy</strong>View Online (EVO) is a web-hosted remote energymonitoring service that eliminates the need to install servers orsoftware on site. The service can either be linked to existingmeters or new PowerLogic meters via an Internet gateway.Schneider Electric can provide end-to-end services includinginstalling and configuring meters and communication devices.Once the necessary hardware is installed and configured, data isdirectly and automatically sent by email to EVO’s secure servers.Simply log in to your personal EVO account <strong>for</strong> 24-7 access toat-a-glance in<strong>for</strong>mation on your building’s energy use:• <strong>Energy</strong> load profile• Normalization• Rate calculations and comparisons• ReportsFor the user> Save2% to 4% offyour utility bills byadapting buildingoperations to actualuse patterns> Reduce buildingoperating costsby 2% to 5%by optimizingequipment use andavoiding unnecessaryinvestments> Analyse costsand manageoperations in realtime without waiting<strong>for</strong> your utility billForprofessionals+ No need toinstall additionalservers or software+ Use existingmeters orincorporate newPowerLogic meters+ Suitable <strong>for</strong>existing buildings+ Easy to installand use; on-sitestart-up andtraining available+ Customsolutions to meetyour specificationsEGX400gatewayPM9Cpower meterION7650power meterION6200power meterPM700power meter> Remote systemmaintenance> Annual servicecontracts andpriority support> Expert analysisand solutions <strong>for</strong>power quality andenergy management<strong>Energy</strong>View Onlineincludes• Secure access to datafrom any computer via aweb browser• Pre-configured energyanalysis reports in bothgraph and table <strong>for</strong>mats:- Load profiles- Usage history- Interval data• Normalization of energyin<strong>for</strong>mation to comparesimilar facilities or thesame facility <strong>for</strong> differenttime periods by:- Square footage- Units of production- Weather• Estimated energy billsusing a revenue-accuraterate engine• Automated reportingand scheduled daily,weekly, or monthly energyreport emails58 59


<strong>Energy</strong> monitoringApplication: small to medium-sized commercial buildings(1,000 to 5,000 square meters)Manage WAGES* in yoursmall to medium-sizedbuilding*Water, Air, Gas, Electricity, SteamBenefitsMeasure Reduce energy consumption Reduce energy costsPowerIncomerInternetExplorerWebMain Low Voltage SwitchboardEthernet modbus TCP/IPMonitoringConsumption analysis(dashboards, curvesand reports)CSV data files downloadCircuit BreakerCompact NSXI need to be able to identify abnormalor atypical consumption easily and at regularintervals so that I can control the overall flowof energy throughout the building.For the userForprofessionals+ Low softwaredevelopment costs:iRio comes withpre-developedsoftware modulesM-BusM-BusInterfacePW60Modbus RS485Remote Terminal Unit (RTU)iRIOSolutionGather metering data via aniRio RTU, track consumption anddetect problemsThe hub of the system is an iRio RTU (Remote Terminal Unit),which picks up metering data from power meters (pulsingcontacts or Modbus Serial Line communication) and flow meters(pulsing contact, Modbus Serial Line communication, or M-Busopen metering communication). The terminal then generates thenecessary databases, dashboards, curves, and reports. It alsotransmits data.The solution detects problems like flow leakages, overrides, andequipment left on, and then provides preconfigured indicatorsand curves at set intervals or on demand via a standard webbrowser as well as a downloadable metering database <strong>for</strong> indepthanalysis.Additional functions are also available, including an alarmgenerator <strong>for</strong> maximum energy consumption overruns, powerfaults, and abnormal consumption cycles and a load controller <strong>for</strong>load shedding, automatic shut down, and override limitation.<strong>Energy</strong> metering can be provided by a number of meter optionsdepending on budget and per<strong>for</strong>mance requirements:• Compact NSX built-in power meter• PM9C/200/700 communicating power meters• Cost-effective EN40/PM9P/ME4zr pulsing power meters> 10% energysavings thanks tousage analysis• Even greatersavings if additionalcontrols likeload scheduling,conditioning sheddingare implemented> Reliable industrialRTU technologyensures in<strong>for</strong>mationis available> Cost-effective• The solution workswith pulse meteringtechnology• Possible small initialrollout to secure quickROI can be scaled uplater with additionalmetering> iRio predevelopedsoftwaremodules minimizesoftware developmentcosts> Web based<strong>for</strong> easyimplementation;no dedicatedworkstation required+ Powerfulcustomizationcapabilities:implement additionalcontrol functions ifand when required+ Less time spenton-site: remotealarm and operation+ No additionalswitchboardcabling: CompactNSX built-in powermeterHeat meterCold meterPM range• PowerLogic large rangeof power meters offeringall the measurementcapabilities required tomonitor an electricalinstallation and arebacked by the mostcomplete range ofmonitoring devices andsoftware on the market• <strong>Energy</strong> class 1 asdefined by IEC 62053-21and class 0.5 as definedby IEC 62053-22WaterWaterGasSensitive loadsPowerMeterPM9CBasic metering+Power MonitoringEN40• Economical KWh meter<strong>for</strong> metering active energyconsumed by a singlephase electric circuit in all< 10kVA installations• Class 1 complies withIEC 62053-21 and IEC61557-12 (PMD DD)Class B complies withEN 50470-3<strong>Energy</strong>MeterEN40Ventilation<strong>Energy</strong>MeterME1/3/4zrAirconditioningSub-metering onlyiRio RTUModular system, withintegrated web server;sends in<strong>for</strong>mation byGSM, GPRS, Ethernet,<strong>Energy</strong>MeterEN40LightingUnmeteredloads(such aspowersockets)ContactorCT/LCControlledload(scheduled,conditioned,shedded)RS485; optional additionalcards <strong>for</strong> external inputsand outputs60 61


<strong>Energy</strong> monitoringApplication: non-critical large industrial buildings > 500 kVAManage WAGES*in non-critical largeindustrial buildingsBenefitsMeasure Reduce energy consumption Reduce energy costsPowerIncomerPossible integration into:> Scada PLC> Manufacturing Execution System (MES)> Building Management System (BMS)> Enterprise <strong>Energy</strong> Management System (EEMS)Main Low Voltage SwitchboardModbus RS485WebInternetExplorerEthernet modbus TCP/IPMonitoringConsumption analysisRemote TerminalUnit (RTU) iRIO*Water, Air, Gas, Electricity, SteamAir circuitbreakerMasterpactWaterI need to make sure my processes arerunning at maximum efficiency without generatingany shortages. Plus, I want a breakdown ofindividual energy costs <strong>for</strong> each workshop.SolutionCombine an iRio RTU, Rio extensionsand meters to track workshopsconsumptionThe system is based on an iRio RTU (Remote Terminal Unit), plusRio extension modules on the secondary switchboards <strong>for</strong> eachworkshop or production line. The terminal and modules pick upmetering data from power meters (pulsing contacts or ModbusSerial Line communication) and flow meters (pulsing contact,Modbus Serial Line communication, or M-Bus open meteringcommunication). The terminal then generates the necessarydatabases, dashboards, curves, and reports and transmits data.The solution provides WAGES consumption in<strong>for</strong>mation <strong>for</strong> eachworkshop or production line, and then provides ratios and curvesshowing each machine’s or each area’s consumption profile.The metering database can be downloaded <strong>for</strong> detailed budgetingand usage optimization needs.Electric metering can be provided by a number of meter optionsdepending on your distribution architecture and meteringper<strong>for</strong>mance requirements:• Masterpact or Compact NSX built-in power meter• PM9C/200/700 communicating power meters• Cost-effective EN40/PM9P/ME4zr pulsing power metersFor the user> 10% energysavings thanks tousage analysis• Even greater savingsif additional controlsare implemented> More efficientoperation andmaintenance> Reduced utilityfees and penaltiesthrough load shedding> Reliable industrialRTU technologyensures in<strong>for</strong>mationis available> Customizabledata processing,user interfaces,reports, andcontrols> Cost-effective• The solution workswith pulse meteringtechnology• Possible small initialrollout to secure quickROI; can be scaled uplater with additionalmetering> iRio predevelopedsoftwaremodules minimizesoftware developmentcosts> Web based<strong>for</strong> easyimplementation; nodedicated workstationrequiredForprofessionals+ Low softwaredevelopment costs:iRio comes withpre-developedsoftware modules+ Flexible dataacquisitioncapabilities (pulse,Modbus SL, M-Bus)<strong>for</strong> compatibility withexisting meters+ Powerfulcustomizationcapabilities:implement additionalcontrol functions ifand when required+ Highly scalable<strong>for</strong> maximum costeffectiveness+ Less time spenton-site: remotealarm and operationPower MeterPM800Masterpact• Nominal current 630 to1600 A• Breaking per<strong>for</strong>mance42 to 150 kA at220/415 V AC• Voltage rating: up to690 VPower MeterPM700Sub-distribution SwitchboardModbus RS485Power MeterPM700Contactor LCControlled load (scheduled,conditioned, shedded)Sub-metering + basic power monitoringPower MeterPM9CPower MeterPM9CContactor CT• 4 Micrologic control unitswith metering, energymanagement and networkanalysis functions• Compliance withIEC 60947-1 and 2,IEC 68230, UL489, ANSI,and CCC standardsPower MeterPM9CM-BusInterfacePW60Power MeterPM9PPower MeterPM9P<strong>Energy</strong> MeterME1/3/4zrSub-metering only<strong>Energy</strong>MeterME1/3/4zr<strong>Energy</strong>MeterEN40M-Bus<strong>Energy</strong>MeterEN40Sub-metering + basic power monitoring Sub-metering only Restricted powerfinal loads withoutsub-meteringiRIO RTU• Central unit of Riomodular system featureswith integrated web server• Sends in<strong>for</strong>mation byGSM, GPRS, Ethernet,RS485GasHeat meterCold meterHeat meterCold meterWaterGasHeat meterCold meter• Optional additionalcards <strong>for</strong> external inputsand outputs• iRio RTU PW60 interfaceaccepts M-Bus Protocolof flow meters62 63


<strong>Energy</strong> monitoringApplication: all commercial buildings greater than 5,000 square metersManage and sub-billWAGES* in largecommercial buildingsBenefitsMeasure Reduce energy consumption Reduce energy costsPowerIncomerPossible integration into:> Building Management System (BMS)> Enterprise <strong>Energy</strong> Management System (EEMS)Main Low Voltage SwitchboardWebInternetExplorerEthernet modbus TCP/IPMonitoringConsumption analysis(dashboards, curvesand reports)CSV data files download*Water, Air, Gas, Electricity, SteamModbus RS485Load controlRemote TerminalUnit (RTU) iRIOI want to make sure I get the most outof my HVAC and lighting control systems.I also need reliable consumption datato sub-bill my tenants’ utility use.SolutionMeter key energy points to acquireconsumption data and identify abnormaluse patternsEach tenant’s utility use is sub-metered, and the resulting consumptionfiles can be downloaded via a standard web browser <strong>for</strong> use with aninvoicing application.Ethernet-based architectures are particularly suitable <strong>for</strong> commercialbuildings where IT network connections are generally already available.The solution is built around an iRio RTU (Remote Terminal Unit) at mainswitchboard level and Twido PLCs distributed at secondary or finalswitchboard level.Metering is provided through power meters using pulsing contactsor Modbus Serial Line communication and flow meters using pulsingcontact, Modbus Serial Line communication, or M-Bus open meteringcommunication.The system ensures data acquisition, processing, and transmission,including database generation, dashboards, curves, and reports.Electric metering can be provided by a number of meter optionsdepending on your distribution architecture and metering per<strong>for</strong>mancerequirements:• Masterpact or Compact NSX built-in power meter• PM9C/200/700 communicating power meters• Cost-effective EN40/PM9P/ME4zr pulsing power metersFor the user> 10% energysavings throughusage analysis• Even greater savingsif additional controlsare implemented> Lower energyconsumptionthrough loadscheduling,conditioning, andshedding> Reliable industrialRTU technologyensures in<strong>for</strong>mationis available> Cost-effective• The solution workswith low-cost pulsemetering technology• Possible low-costinitial rollout to securequick ROI; can bescaled up later withadditional metering• iRio pre-developedsoftware modulesminimize softwaredevelopment costs• Uses existingIT infrastructure(Ethernet TCP IP)> Web based<strong>for</strong> easyimplementation; nodedicated WAGESworkstation required> Ready-to-usedata files facilitatesub-billingForprofessionals+ Low softwaredevelopment costs:iRio comes withpre-developedsoftware modules+ Powerfulcustomizationcapabilities:implement additionalcontrol functions ifand when required+ Highly scalable<strong>for</strong> maximum costeffectiveness+ Uses existingIT infrastructure(Ethernet TCP IP):no need to installnew communicationbus+ Less time spenton-site: remotealarm and operationAir circuitbreakerMasterpactPower MeterPM800Masterpact• Nominal current 630 to1600 A• Breaking per<strong>for</strong>mance42 to 150 kA at220/415 V AC• Voltage rating: up to690 V• 4 Micrologic controlunits enriched bymeasurement, energyPower MeterPM9CControlled load (scheduled,conditioned, shedded)Sub-metering + basic power monitoringSub-distribution SwitchboardLightingfeederPower MeterPM9C<strong>Energy</strong> MeterEN40Power MeterPM9CContactor CTHVAC feeder(fan coils)<strong>Energy</strong> MeterME 1/3/4zrmanagement and networkanalysis functions• Compliance withIEC 60947-1 and 2,IEC 68230, UL489, ANSI,and CCC standardsPowerLogic Series800 Power Meters• IEC 62053-22 class0.5S <strong>for</strong> real energyM-BusInterfacePW60Power MeterPM9PNon meteredfeeders(e.g. power sockets)<strong>Energy</strong> MeterME1/3/4zrSub-billing onlyM-Bus<strong>Energy</strong>MeterEN40Twido PLC based Ethernetpulse concentrator• Accurate energymeasurement <strong>for</strong> subbillingand cost allocationiRIO RTU• Central unit of modularsystem features withintegrated web server• Sends in<strong>for</strong>mation byGSM, GPRS, Ethernet,RS485WaterGasHeat meterCold meterHeat meterCold meterWaterGasHeat meterCold meter• Optional additionalcards <strong>for</strong> external inputsand outputsTwido programmablecontroller• Compact basecontrollers with integratedEthernet port• 100…240 V AC supplyor 24V DC64 65


<strong>Energy</strong> monitoringApplication: all large, non-critical industrial buildings (>1,000 kVA)Analyze energy datato optimize operation ofyour industrial buildingsBenefitsMeasure Reduce energy consumption Reduce energy costsAir circuitbreakerMasterpactPowerIncomerPower MeterPM850/870 ECCION EnterprisesoftwareEthernet TCP/IPInternetExplorerIntranetMain Low Voltage SwitchboardI need a complete system to managemy water, air, gas, electricity, and steam (WAGES)consumption and reduce maintenance costs.SolutionUse ION Enterprise software to acquireenergy meter and circuit breaker data<strong>for</strong> complete installation monitoringThe solution delivers the indicators, curves, and trends you need to:• Identify potential savings• Pinpoint investment opportunities that can help you use less energy, likelighting, heating or air treatment control systems• Assess your installation’s per<strong>for</strong>mance via status and fault alarms andmeasurementsION Enterprise power monitoring and control software features:• <strong>Energy</strong> metering (WAGES) and power monitoring data acquisition(voltage, current, power factor) through:- SEPAM, Masterpact, and Compact NSX power meters with integratedprotection- PM, CM, and ION power meter ranges- Remote devices connected via the Internet, Ethernet, wireless, modem,satellite and serial connectionsThe software controls loads and power sources, peak rate management,and power factor correction.Advanced data management:• Load aggregation, multi-site meter aggregation and trending, billverification, cost allocation and sub-billing• Trigger on complex conditions, alarming, event logging, power qualityanalysis and compliance monitoringAdvanced in<strong>for</strong>mation delivery:• Web-enabled, local or remote preconfigured and custom reports• Manual, scheduled or event-triggered reports via email or webFor the user> 10% energysavings throughconsumptiontracking> Coversfull WAGES(water, air, gas,electricity, steam)consumption> Reduced energycosts by avoidinghigher utility contractfees and penaltiesthrough demandresponse andcurtailment programs> Increase loadsand equipmentlifetimes by detectinganomalies on theinstallation> Boost reliabilityof in<strong>for</strong>mationby gaining acomprehensiveoverview of all energymanagement data viaa single system> Enjoy greaterflexibility with fullycustomizable dataprocessing, userinterfaces, reports andcontrolsForprofessionals+ Full Modbus andOPC connectivityto third-partymeters, sensors andother equipment+ Highinteroperabilitywith thirdpartysystems,applications andservices such asBAS, MES and ERPvia ODBC, OPC,XML, FTP, email,CSV, PQDIF+ Cost-effectiveimplementationthroughpreconfiguredreports+ Optimisedcost through fullyscalable hardware,software and systemarchitecture+ Power meterswith built-inprotection deliverswitchboardinstrumentationwithout installingdedicated powermeters.Sepam, Masterpactand Compact NSXenable fullmonitoring acrossthe entire powerdistributionarchitectureWaterGasEGX100gatewayKey loads to be monitored:- Big consumers- Requiring availabilityION E V6.0• Compatible with allPowerLogic ION-seriesmeters, PowerLogicPM750 and PM710meters• Supports third-partymeters, sensors andother equipment throughModbus protocol or OPC• Connect to remotedevices via Internet,Ethernet, wireless,Circuit breakerCompact NSXModbus RS485Circuit breakerCompact NSXPeak shaving,load sub-meteringand monitoringSheddedfinal loadsContactor CTmodem, satellite, andserial connections• Integrated metering ofall utilities (water, air, gas,electricity, steam)• Enterprise web portalaccess to system-widedisplays• Preconfigured andcustom reports, reportwizard, scheduleddistribution via email orwebCircuit breakerCompact NSXLoads to besub-meteredand monitoredPowerMeterPM9CContactorLCShedded loadsPowerMeterPM9C<strong>Energy</strong>MeterME 1/3/4zrPLC basedsubmeteringconcentratorTwido based<strong>Energy</strong>MeterEN40Loads to be sub-meteredonly, not requiring anymonitoringPLC basedload sheddingcontrol unitTwido basedSub-distribution Low Voltage Switchboard• Power quality analysisincluding compliance withinternational standards(IEC 61000-4-30,EN50160)PM 850• Easy to install panelmountwith only two clips,or DIN rail mount with orwithout remote display• Direct-connect voltageinputs, with no need <strong>for</strong>Small loadswhithout anysub-meteringpotential trans<strong>for</strong>mers(PTs) up to 600 VAC• Intuitive navigation withself-guided, languageselectablemenus• Individual harmonicmagnitudes and anglesand wave<strong>for</strong>m capture(PM850 and PM870)• IEC 62053-22 class0.5S <strong>for</strong> real energy66 67


For many buildings, HVAC and lightingcombined account <strong>for</strong> over 70% ofenergy use.You can optimize this major source of energyconsumption by installing a powerful, integratedBuilding Management System based on open,scalable devices and applications.In addition to measuring consumption data andtransmitting it to automated systems, our BuildingManagement Systems deliver capabilities likecomplex data analysis and detailed consumptiontrend reporting while integrating consumptionand installation control features.These solutions are within reach <strong>for</strong> all buildings,regardless of type of use, current installation,or budget.Choose the solution that’s right <strong>for</strong> you> Schedule selected loads simply via your BMS (p. 70)> Monitor and control electrical loads in your retail store (p. 72)> Control lighting and heating at room level with a KNX-based system (p. 74)> Control room lighting, temperature, and blinds automatically (p. 76)> Manage hotel energy consumption according to guestroom occupancy (p. 78)> Reduce hotel electrical consumption and improve com<strong>for</strong>t with a full KNX system (p. 80)> Combine various control systems to achieve maximum savings (p. 82)> Monitor your building’s power supply and control HVAC, lighting, and blinds (p. 84)> Boost energy efficiency and increase the availability of your electrical installation (p. 86)> Control and monitor HVAC, lighting, security systems, and energy consumption (p. 88)Building management6869


Building managementApplication: any building with a Building Management SystemSchedule selected loadssimply via your BMS** Building Management SystemBenefitsMeasure Reduce energy consumption Reduce energy costsEthernetPC or PLCcontrollerExisting BMSMy business is flexible enough to schedulecertain energy-consuming activities during lessexpensive off-peak hours. What’s the best wayto take advantage of this opportunity?SolutionIntegrate a centrally-managedload-shedding system into your BMSThe solution is built around a PC or PLC that controls loadshedding. The controller is used to generate load shedding ordersbased on the electrical variables of the entire electrical installation,taking into account time bands, operating, or even processrelatedin<strong>for</strong>mation. The system communicates with selectedCompact NSX circuit breakers. Power to outgoing loads is cut <strong>for</strong>a given amount of time, and selected loads are restarted at moreoptimal times chosen by the controller.The system is simple, with an IFM Modbus interface between thePC or PLC and the circuit breakers. The Compact NSX circuitbreakers are equipped with Breaker Status Control Module(BSCM) input/output modules, which are hooked up to the remotecontrol (MTc) that opens and closes the Compact NSX.For the user> 10% lowerelectricity bills, withsavings proportionateto rates negotiatedwith the utility> Get the most ofyour investment:the FDM121switchboardincludes, at a costsimilar to traditionalpush-button/lighting/commutatorsolutions,• local circuit breakeropen/close command• local/remotecommutatorForprofessionals+ Easy designand use• Limited partnumbers <strong>for</strong> easyselection andordering• Available worldwide+ Easy installation• The circuitbreaker’s integratedcommunicationcapabilities eliminatethe need <strong>for</strong> I/Owiring between thecircuit-breaker andthe PLC• RJ 45 connectionsbetween the circuitbreakers and thecommunicationnetwork• The FDM121mounted on astandard cutout onthe front panel iseasy to install withits RJ 45 connection+ Easy testing andconfiguration,using your PCinstalled with RCU*software* Free downloadavailable online at www.schneider-electric.com+ Efficientoperation andmaintenance,thanks to theFDM121’scentral and localmanagementcapabilitiesCircuit BreakerCompact NSXwith remotecontrol (MTc)BoilerIFMModbusCompact NSX100-630Circuit breaker withremote control (MTc)BSCM (BreakerStatus ControlModule)I/O module sends circuitbreaker O/C status andO/C commandsEGX100gatewayFront display moduleFDM121BSCM(Breaker StatusControl Module)FDM121 switchboarddisplay unit• Local measurement andalarm readings• Local circuit breakerO/C command with statusdisplay• Local/remote circuitbreaker commandmanagement• Connected to Modbusnetwork via interfacemoduleEthernet/Modbus EGX100communicationgateway70 71


Building managementApplication: all commercial buildings; particularly suitable <strong>for</strong> retailMonitor and controlelectrical loads in yourretail shopfrontBenefitsMeasure Reduce energy consumption Reduce energy costsKNXpush-buttonIP Touch-panel 10"24V=Low voltagePower supplyI need to be able to check the statusof the oven, refrigerator and security camerasquickly and easily when I close up my shop.I want to make sure everything is secure andavoid wasting energy.System component Logic control Load controlManual control Visualization KNXKNXPowersupplyKNXLogic moduleBasic Reg-KKNXSwitch actuatorREG-K/8x230/16with manual modeand current detectionSolutionInstall KNX current sensing switchactuators connected to a touch panelto monitor loadsThe touch panel shows the status of the different loads andindicates potential risks—such as the refrigerator, oven, or securitysystem—during shop opening hours.The system cuts power to specific loads—like an oven left onat night—thus eliminating waste. It also helps to ensure properoperation of the security system by monitoring devices likesecurity cameras and lighting.A KNX logic module rotates the lighting sources used at nightfrom one night to the next <strong>for</strong> more even use of light fixtures.The touch panel provides in<strong>for</strong>mation on the operating hours andexpected lifetime of each fixture, <strong>for</strong> more efficient maintenanceand replacement.For the user> Monitoringconsumptionand identifyingunnecessary usecan generatesavings of up to10% and more> Lowermaintenance costsby rotating lightingsources> Reduce energyconsumption> Increase safetyof people andproperty throughautomatic alarms andemergency calls> Addedconvenience ofremote monitoringand control> Easy upgradesand extensionsForprofessionals+ KNX systems areeasier to designthan traditionalsystems with similarfunctions+ Requiresworking with askilled electricianor planner/integrator to getmaximum userfriendlinessandcost-effectiveness+ Maximumflexibility, makingadjustments tolayout much easierthan with traditionalsystemsMotorsFridgeOvenMonitoringREG-K/8x230/16switch actuator withmanual mode andcurrent detection• Capacity to switch eightloads independently• Integrated currentdetection on each channel• Nominal voltage: AC230 V, 50 - 60 Hz• Nominal current Perswitching contact: 16 A,cos = 0.6The 10”KNXinteractive touchpanel is used to displayand control buildingstates and functions. Itcomes pre-installed withWindows CE <strong>for</strong> fast, easydata management, web,client/server, and networkconfiguration• KNX softwareconfiguration via TP VISU• Display size: 10.4”(24.4 cm)• Resolution: 800 x 600pixels, SVGAballastFluorescent230 Volt• Display type: TFT,resistive touch• Colours shown:> 65,000• Mains voltage: DC 24 V• Power consumption:< 20 W• RAM: 128 MB72 73


Building managementApplication: all commercial buildingsControl lighting andheating at room level witha KNX-based systemBenefitsMeasure Reduce energy consumption Reduce energy costsKNXARGUSPresence sensorKNXmulti-functionpush-buttonSystem componentLighting controlTemperature controlWe are reorganising our office space.We are looking <strong>for</strong> a simple, yet flexible systemthat will enable us to start saving on heatingand lighting right now.For the userKNXPowersupplyKNXSwitchactuatorKNXBinary inputmoduleManual controlKNXHeatingactuatorKNX> Room automationreduces energyconsumptionForprofessionalsWindowcontactsThermoel.valve drivesSolutionInstall a KNX-based room-levelcontrol system <strong>for</strong> lighting andheatingThe solution offers an optimum combination of different controllevels: presence, brightness, time-dependency <strong>for</strong> lighting,and temperature.Settings are adjusted via KNX presence detectors, lightingand heating actuators, binary inputs, and multi-function pushbuttoncontrols. Automatic interaction of sensors and actuatorseliminates unpredictable—and costly—human activation anddeactivation <strong>for</strong> increased com<strong>for</strong>t and safety.The solution is much more flexible than traditional installations<strong>for</strong> easy repurposing of office spaces after a reorganizationor move.• Lighting control: the bus system includes a presencedetectorand multi-function push-button control.• Heating control: the multi-function push-button controlsroom-temperature and switches to standby whenever the roomis unoccupied or a window is open.• According toEU standardEN 15232, Class Aoffi ce buildings mustbe equipped withroom-level controls,which have thegreatest impact onenergy consumption.KNX room controlsolution combinespresence- andbrightness-controlledlighting with presencecontrolledheating andwindow monitoring,<strong>for</strong> potential energysavings of upto 35%> Increased safetywith automatedalarms andemergency calls> Easy to upgradeor add on to thesystem+ Saves timeon installation:easier to install thantraditional systemswith similar functions+ Newopportunities <strong>for</strong>your business:KNX solutions mustbe implemented byskilled electriciansor integrators andoffer an array ofuser-friendly, costeffectivefunctionsKNX multi-functionpush-button withroom temperaturecontrol unit• Convenient controlunit with four operatingbuttons• Includes roomtemperature controlunit and display <strong>for</strong>:- Switching, toggling,dimming, blind control,pulse-edge trigger,alarm functions,cyclical reading ofexternal temperatures,etc.- Continuous PIcontrol, switching PIcontrol (PWM)• Output: continuous• Type of control: 2-step control range 0%to 100% or on/offKNX heating actuator• For actuation ofthermoelectric valvedrives <strong>for</strong> heating orcooling ceilings• Six electronic outputs• Up to four valvedrives can beconnected to eachoutput• Outputs are eitherswitch activated (1 bit)or PWM signal (1 byte)activated• Each output isoverload-protected andshort-circuit-protected• For installation onEN 50022 DIN rails• Reporting connectedto all valves,transmission of thelargest 1 byte variablevalue• Nominal voltage:AC 230 V, 50-60 Hz• Nominal current:0.05 A, ohmic• Starting current:max. 1.5 A• Minimum load perused output: 1 valvedrive• Number of valvedrives max. 4 peroutput• Device width:approximately 72 mm<strong>for</strong> four modulesKNX binary inputmodule• Switching, dimmingor blind control via oneor two inputs• Positioning values <strong>for</strong>blind control (8-bit)• Pulse edges with1-, 2-, 4-, or 8-bittelegrams• Differentiationbetween short/longoperation• Initialisation telegram• Cyclical transmission• Pulse edges with2-byte telegrams• 8-bit linear regulator• Disable function• Break/make contact• Debounce time• Inputs: 474 75


Building managementApplication: all types of buildingsControl room lighting,temperature, and blindsautomaticallyBenefitsMeasure Reduce energy consumption Reduce energy costsRemote controlSystem componentKNXARGUSPresence sensorLighting controlTemperature controlKNXmulti-functionpush-buttonSunblind controlManual controlKNXI want to automatically manage my building’slighting and air conditioning depending onoccupation, orientation, and natural light.SolutionCombine a variety of room-levelcontrols <strong>for</strong> dramatic cost savingsThe solution is built around KNX detectors and fan andblind actuators, which interact automatically, eliminatingunpredictable—and costly—human activation and deactivation.By combining presence and brightness detectors with timersto control lighting, blinds, heating, and air conditioning, you cansave dramatically on your energy bills while increasing occupantcom<strong>for</strong>t and safety.Lights are switched on only when areas are occupied anddepending on natural light. Heating and air conditioning areautomatically regulated to achieve the desired temperature,switching to standby mode in the event of prolonged absenceor if a window is open. Blinds are activated according to roomtemperature.For the user> Save up to50%• Combining roomclimate control,lighting, and blindsin a single fl exible,automated system isthe best way to alignenergy consumptionwith room use andoccupant behaviorwhile eliminatingwaste• According to EUstandard EN 15232,Class A offi cebuildings must beequipped with roomlevelcontrols, whichhave the greatestimpact on energyconsumption• All-in-one solution<strong>for</strong> optimized roomcontrol• Reduces energyconsumption• Flexible, withcentralized or localswitching andindicators• Increased safetywith optionalautomated alarms andemergency calls• Optional userfriendlyremotemonitoring and control• Easy to upgrade oradd on to the systemForprofessionals+ Saves time ondesign (supportavailable) andinstallation (easierto install thantraditional systemswith similarfunctions)+ Facilitatesmaintenance+ More flexiblethan traditionalsystems; can bechanged easilyif when tenantsmove out or whenworkspaces arereorganizedKNXPowersupplyKNX Argus presencedetector with lightingcontrol and IRreceiver• Angle of detection: 360°• Range: a radius of max.7 m (at a mounting heightof 2.50 m)• Number of levels: 6• Number of zones:136 with 544 switchingsegments• Number of movementsensors: 4, separatelyadjustable• Light sensor: internal lightsensor infinitely adjustablefrom approx. 10 Lux to2,000 Lux (ETS); externallight sensor via KNXKNXControl-unit0-10 VREG-K/4x24/6 blindactuator with manualmodeFor independent controlof 4 blinds or roller shutterdrives.The function of theblind channels is freelyconfigurable. All blindoutputs can be operatedmanually using pushbuttonoperation.• Integrated bus coupler• For installation onto DINrails EN 50022KNXFan coilactuatorHeatingvalve drivesFan coilsWindowcontacts• For each blind output:- Nominal voltage: DC24 V ±10 %- Nominal current: 6 A- Load types: 24 V directcurrent drives- Device width: 4 modules= approx. 72 mm- Contents: With busconnecting terminal andcable coverKNX REG-K fan coilactuatorFor heating, ventilationand air conditioningcontrol. For controllingKNXBlindactuatorShuttersBlindsfan convectors with up tothree speeds, or threestepmotor drives.• Power supply: 230 VAC ±10 %, 50/60 Hz• Power consumption:max. 3 VA• Outputs: 3 floatingcontacts (fan coil), 2semi-conductor switches(valve connections)• Switching capacity <strong>for</strong>valves: 0.5 A, 24V - 230 VAC• Additional relayswitching capacity: 16 A• Fan relay switchingcapacity: 8 A• Inputs: 2, max. cablelength 5 m76 77


Building managementApplication: four- and five-star hotelsManage hotel energyconsumption accordingto guestroom occupancyMy hotel’s occupancy rates fluctuate depending on thetime of year, something that is not reflected in my energycosts. I want a system that will help me keep costs in linewith occupancy and boost my hotel’s profitability.SolutionIntegrate guestroom managementinto your hotel’s reservation systemYour hotel’s Property Management System (PMS) handlesreservations, but it can also provide in<strong>for</strong>mation about the statusof each room: rented, rented and unoccupied, or rented andoccupied. When the PMS and the guestroom managementsystem interface, this in<strong>for</strong>mation can be used to optimize roommanagement and even save guest preferences <strong>for</strong> automaticcustomization of settings when the guest checks in.Schneider Electric offers both guestroom management systemsand complete building management systems, and delivers theexpertise needed to integrate these systems into third-partyProperty Management Systems like Micros Fidelio and Opera.In<strong>for</strong>mation concerning functions like temperature, lighting andelectricity—managed at room level—can be monitored andcontrolled in line with in<strong>for</strong>mation from the Property ManagementSystem, <strong>for</strong> instance:• Unrented: Room is in economy mode. Room lights are turned off.Room heating or air conditioning is automatically lowered. Windowblinds and ventilation are set to maintain optimal conditions whilethe room is unoccupied.• Rented and unoccupied: Room is in pre-com<strong>for</strong>t mode.Temperature and air quality can be automatically set to a positioncloser to com<strong>for</strong>t mode.• Rented and occupied: All room settings can be adjusted by theguest.BenefitsFor the user> Reduce energyuse by more than20%> Opt <strong>for</strong> simpleguestroommanagement (tolower heating or airconditioning whileguests are awayfrom their rooms)<strong>for</strong> savings of10%;add advancedmanagement ofunrented rooms <strong>for</strong>an additional 10%savings> Guests retaincontrol of theirenvironment whilein their rooms <strong>for</strong>total com<strong>for</strong>t andease of useForprofessionals+ Simplecommunicationbetween thesystems viaa gatewayensures easyimplementationand integrationMeasure Reduce energy consumption Reduce energy costsProjectsHilton Americas-Houston becomes one ofthe world’s most energy-efficient hotelsFor this 24-story facility with 1,200 guest roomsand over 91,000 square feet (84,500 m 2 ) ofmeeting space, Schneider Electric provided acomprehensive Andover Continuum buildingmanagement system with a unique, energysavingguest room control sequence.Hilton Copenhagen Airport automatesHVAC according to guest check-in andcheck-outFor this fi ve-star, 382-room hotel, SchneiderElectric focused on fi nding a practical way tokey the HVAC system to guest arrivals anddepartures. The solution used a LonWorks ® -based TAC Vista system and integratedHVAC control with the hotel’s booking systemto trigger heating and cooling adjustmentswhen guests check in and out.PMS GatewaySchneider Electric’s open BuildingManagement System line-up featuringAndover Continuum and TAC Vista enables fullintegration of all hotel equipment, providing a centralpoint of control and communication with third-partysystemsTemperature Setpoint8482807876747270686664Cooling SetpointHeating SetpointUnrentedRented,UnoccupiedSchneider ElectricBuilding ManagementSoftwareOpen Field Communication BusFloor 1: roomsFloor 2: roomsRented,Occupied78 79


Building managementApplication: four- and five-star hotelsReduce hotel electricalconsumption and improvecom<strong>for</strong>t with a full KNX systemBenefitsMeasure Reduce energy consumption Reduce energy costsEnclosure ofKNX actuators<strong>Energy</strong> has become a major expense <strong>for</strong> myhotel. I would like to reduce costs, but not to thedetriment of my guests’ com<strong>for</strong>t or my own peaceof mind—my top priorities.For the userKNX/EIB busSolutionInstall an intelligent guestroommanagement system to controllighting, HVAC, and blindsThis intelligent system controls lighting, HVAC, and blinds accordingto guest presence, ensuring maximum com<strong>for</strong>t via the followingfunctions:• Advanced control of all room equipment such as lighting, heating,air-conditioning, curtains, and blinds• Management of hotel functions like do-not-disturb and make-upthe-roomorders• The capacity to communicate with other hotel systems<strong>Energy</strong> use is managed automatically according to occupancy,resulting in reduced energy consumption. Of course, HVAC is atop consumer of energy, but so is lighting. Guests are usually onlyin their hotel rooms <strong>for</strong> around eight hours per day, there<strong>for</strong>e, thetimes when the room is unoccupied represent a major opportunityto save energy without affecting guest com<strong>for</strong>t.The solution is based on a KNX/EIB bus system, which connectsall the different sensors and actuators inside the room to <strong>for</strong>m anintelligent system.• Sensors: key card holder, presence detector, thermostat, open/close windows• Actuators: lighting control, air conditioning control• A single, easy-to-use interface, from simple push buttons touser-friendly touch screens• Automated functions provide additional energy savings andsmoother operation, whithout any inconvenience <strong>for</strong> the guests> 10% energysavings off eachguestroom’s electricbill• By lowering roomtemperature by justone degree, youcan shave 3% off ofyour HVAC system’senergy consumption• Achieve additionalsavings through smartlighting and blindmanagement> Ensure greatercom<strong>for</strong>t and anenhanced experience<strong>for</strong> your guests• Install a convenientcentral point of control(bedside, <strong>for</strong> example)• Provide one-touchaccess to selectedlighting scenarios• Eliminate the needto turn off each lightwhen leaving the roomor going to sleepForprofessionals+ A differentiatingdesignA skilled electricianor systemsintegrator must bebrought in to installthe guestroommanagement systemto ensure maximumuser friendliness andcost effectiveness+ Easy upgradesand add-onsThanks to theflexibility of thebus system, thesystem can beeasily upgradedwith new functionsduring future hotelrenovationsSchneider Electricprovides a completerange of hotelguestroom productsdesigned to workseamlessly together.• Customer-facingproducts are designedwith ease-of-use inmind• Available in abroad array of stylishfinishes to match theinterior design of theguestroomGuestroomthermostatCard key holder<strong>for</strong> installation in roomentrance turns roomsystems on and offwhen guests enter andleave the room• Cover the full rangeof needs unique tohotel guestroom use80 81


Building managementApplication: large commercial buildings (> 5000 m²)Combine various controlsystems to achievemaximum savingsBenefitsMeasure Reduce energy consumption Reduce energy costsSupervisionworkstationBACnet over TCP-IP networkRouter toIT networkWe want our new head office to be asenergy-efficient as possible while deliveringthe level of com<strong>for</strong>t our employees need. Onegoal we have is to reduce operating costs andsecure green certification <strong>for</strong> our building.Install a multi-technique BuildingManagement System (BMS) to superviseheating, cooling, air conditioning, ventilation,power, elevators, plumbing, access control,lighting, and blindsFor the user> Achieve 30%energy savingsby controlling theentire installation andraising occupantawareness ofconsumption> Pinpoint areas<strong>for</strong> potential energysavingsForprofessionals+ Reconfigureworkspaceswithout recabling+ Enjoy theconvenience ofstandard lighting(DALI) and motor(SMI) interfaces+ Use lightingand ballast statusin<strong>for</strong>mation tohelp reducemaintenance costsPower supplyLONLON networkSMIgatewayBusBlindsDALIgatewayBusLightingsRouterBACnet/LONOfficenetworkControllerXenta 110HVACRouterBACnet/LONOthertechnicalnetworkWall displaysensorsMerten ArtecRouterBACnet/LONCCTVnetworkRF receiversRF remotecommandSolutionThe solution is built around a TAC Continuum supervision system andsubsystems made up of gateways and command-control devices <strong>for</strong> differentapplications:• An SMI system <strong>for</strong> window blind control• A DALI system <strong>for</strong> lighting control• Xenta controllers <strong>for</strong> the air conditioning system• An access control and video surveillance systemHeating is programmed on an hourly basis and setpoints are checkedto ensure that building temperature is lowered at night and raised be<strong>for</strong>eoccupants arrive in the morning. Presence detectors plus automatic lightingshutoff functions with re-start capabilities provide further energy savings evenwhen employees work after normal office hours.Daylight and presence detectors are used to optimize regulation of lightingand air conditioning in each individual office. Lighting, window blind, and coldbeams are managed by system scenarios such as presence, natural light,arrival (first occupant), departure (last occupant), and others.The solution enables facilities managers to view the status of, monitor, andoperate all systems throughout the building, including alarms, temperatures,faults, on/off, and more.The TAC Continuum system offers a display detailing energy consumptionthroughout the building, providing the specific in<strong>for</strong>mation needed to raiseoccupant awareness of energy consumption and savings.> Enhanceemployee workingconditions> Project ahigh-tech,environmentallyawareimageExample ofSchneiderElectricheadquartersSchneider Electricrecently built anew head officejust outside Paris,France. The sixstoreybuilding offers35,000 square metersof office space <strong>for</strong>1,700 employees.After the November2008 move-in, thebuilding generatedenergy savings of€250,000 over a fivemonthperiod—that’s35% savings off theprevious head office’senergy bills.The LON DALI-Gateway can beconnected to four DALIcontrol units. Up to256 devices, dividedinto 64 DALI groups,can be connected.Example of display screens in the Schneider ElectricHeadquartersThe LON SMIController (Gateway)has four SMI-outputsto control up to16 SMI-Slaves (motors)each. Up to 64SMI motors can becontrolled.82 83


Building managementApplication: all commercial and industrial buildingsMonitor your building’s powersupply and control HVAC,lighting, and blindsBenefitsMeasure Reduce energy consumption Reduce energy costsPowerIncomerAir circuitbreakerMasterpactMain Low Voltage SwitchboardLonTalk Ethernet TCP/IPModbus RS485Building Automationsupervision softwareTAC VistaInternetExplorerIntranetMultiprotocolIP controller,gateway andweb serverTAC Xenta 731I want to deliver the level of com<strong>for</strong>t my building’soccupants expect while limiting energy costs. I alsoneed to ensure that my equipment is available andkeep operating and maintenance costs to a minimum.SolutionInstall a Building Management Systemto monitor and control your building’sequipment and provide energy consumptiondataBased on the TAC Vista Building Automation and Control System, thesolution integrates the best of both power monitoring functions and HVAC,lighting, and blind control capabilities thanks to data acquisition via Xenta 731multi protocol IP controllers.The solution provides comprehensive managed energy data covering water,air, gas, electricity, and steam (WAGES) via TAC Xenta 400 I/O modules oradditional PM850 digital inputs. Electric metering is provided by the PM meterrange and Masterpact and Compact NSX meters with built-in protection.TAC Xenta 4XX and 3XX controllers run HVAC, lighting and blinds, as well asloads and power sources.TAC Vista software provides advanced data management, including• Load aggregation, multi-site meter aggregation and trending, bill verification,cost allocation and sub-billing• Trigger on complex conditions, alarming, event logging, power qualityanalysis and compliance monitoring• Coordinated control functions and complex calculationsAdvanced in<strong>for</strong>mation delivery• Web-enabled, local or remote preconfigured and custom reports• Manual, scheduled or event-triggered reports via email or web• Trend graphing <strong>for</strong> any parameter measured• Analysis of efficiency, losses, and capacityScalable architecture• IP-based communication via existing building IT infrastructure• Internet communication tools <strong>for</strong> remote or local operationFor the userHelps achieveEuropean BuildingAutomationand ControlSystem standardIEC EN15 232 targetsavings <strong>for</strong> differentcontrols> Heating energysavings of around30%> Electrical energysavings of around13%Forprofessionals+ AdvancedTAC toolsdeliver increasedefficiency to systemintegrators andcontractors+ Compatiblewith all SchneiderElectric meteringdevices+ Powerfulcustomization <strong>for</strong>easy implementationof all power controlfunctions+ Highly scalablesystem, hardware,and softwarearchitectures <strong>for</strong>maximum costeffectiveness+ Remotealarming, reporting,and operation <strong>for</strong>reduced on-sitepresenceWaterGasPower MeterPM9P<strong>Energy</strong>MeterEN40LightingTAC Xenta 731multiprotocolcontrollers providea broad array ofcommunicationcapabilitiesCircuit breakerCompact NSXControllerTAC Xenta 411/421<strong>Energy</strong>MeterME 1/3/4zrHVAC loads(Fan Coils)Sub-metering onlyPowerMeterPM850/870 ECCShedded final loadsFTT-10,LonTalkNon monitoredloads such as powersocketsMultiprotocolIP controller,gateway andweb serverTAC Xenta 731Sub-distributionLow VoltageSwitchboard• Open LonWorks © fieldbus compatible with multivendorequipment:- Fan coil, cold beam orair handling unit controllersPowerMeterPM9CContactor CTLightingPowerMeterPM9CLoad sub-meteringand monitoringSub-distributionLow VoltageSwitchboardPowerMeterPM9CControllerTAC Xenta 411/421HVAC loads(Fan Coils)Sub-metering only- Lighting controllers- Sensors and actuators• Modbus communication<strong>for</strong> power monitoring andcontrolModbus RS485PowerMeterPM9CFTT-10, LonTalk<strong>Energy</strong>MeterME 1/3/4zr<strong>Energy</strong>MeterEN40Loads to be sub-meteredonly, not requiring anymonitoringMultiprotocol IPcontroller, gatewayand web serverTAC Xenta 731Non monitoredloads such as powersockets84 85


Building managementApplication: all large critical industrial buildings (>1000 kVA)Boost energy efficiencyand increase the availabilityof your electrical installationBenefitsMeasure Reduce energy consumption Reduce energy costsAir circuitbreakerMasterpactEthernet TCP/IPPowerIncomerION Enterprisesoftware<strong>Energy</strong> & Power Quality MeterION 7650PowerLogic ® SCADAsoftwareMain Low Voltage SwitchboardGensetInternetExplorerIntranetHow can I save energy in an industrial buildingwhere there’s zero tolerance <strong>for</strong> power cuts?ForprofessionalsWaterGasModbus RS485PowerMeterPM9CCombine ION Enterprise power monitoringsoftware and Power SCADA operations andmaintenance management software+ Compatiblewith all SchneiderElectric products,includingPowerLogic IONseriesmeters andPowerLogic PM750and PM710 metersCircuit breakerCompact NSXCircuit breakerCompact NSXShedded loadsContactorLCSourceTransferSwitchCompactNSXSourceTransferSwitchControllerUBA BAUPSGalaxy 6000SolutionThe solution delivers a detailed analysis of events while optimizing control ofyour building’s power supply.ION Enterprise software manages energy-efficiency-related functions• Comprehensive managed energy in<strong>for</strong>mation:> Electric metering through PM and CM meter ranges and Sepam,Masterpact, and Compact NSX meters with built-in protection- Electric parameters: voltage, current, frequency, power factor- Power and energy parameters: apparent, active, reactive- Power quality> Load aggregation, trigger on complex conditions, alarming, event logging,trend graphing <strong>for</strong> any measured parameter, analysis of efficiency, losses andcapacity, bill verification, cost allocation, and sub-billing> Web-enabled, local or remote preconfigured and custom reports; manual,scheduled or event-triggered reporting and distribution via email or web• Load and power source controls; demand and power factor correction> Collection of all WAGES (water, air, gas, electricity, steam) metering datathrough additional meters or directly via Ethernet, from a PLC-SCADA <strong>for</strong>examplePowerLogic SCADA mainly addresses availability related functions• Real-time monitoring and control of the entire power installation <strong>for</strong> even themost complex facilities• Advanced alarm and shift management functions <strong>for</strong> smoother maintenancescheduling• Powerful troubleshooting thanks to precision time stamping accurate towithin 1ms• Advanced communication architectures : hot/warm redundant I/O deviceconfiguration, self-healing ring communications and primary and standbyserver configurations• Fast manual control operations by clicking on-screen trigger buttons, andremote breaker, protection relay, and other power distribution equipmentoperationFor the user> Reduce energyconsumption by10% by analyzingusage> Implementadditional controlssuch as curtailmentprograms <strong>for</strong> evengreater savings> Improveavailability ofyour facilitiesthrough fasteraccess to decisioncriticalreports andautomated multisourcecontrols> Increase accuracyof monitoring andtroubleshootingwith highly-accurate1ms time stampingcapabilities+ Connectivity tothird-party devicesvia Modbus or OPC+ Powerfulcustomizationfacilitatesimplementation ofall power controlfunctions+ Remotealarming, reporting,and operation <strong>for</strong>reduced on-sitepresenceKey loads to bemonitored:- Big consumers- RequiringavailabilityEGX100gatewayCircuit breakerCompact NSXModbus RS485Peak shaving,load submeteringandmonitoringION E V6.0 software• High interoperabilitywith third-party systems,applications, and servicessuch as BAS, MES, andERP via ODBC, OPC,XML, FTP, email, CSV,and PQDIFSheddedfinal loadsContactorLCPowerMeterPM9CLoadssub-meteringand monitoringSub-distribution Low Voltage Switchboard• Integrated metering ofall utilities (water, air, gas,electricity, steam)• Enterprise web portalaccess to system-widedisplays• Power quality analysisincluding compliance with<strong>Energy</strong>MeterME 1/3/4zrPLC basedsubmeteringconcentratorTwido based<strong>Energy</strong>MeterEN40Loads to be sub-meteredonly, not requiring anymonitoringSmall loadswhithout anysub-meteringinternational standards(IEC 61000-4-30,EN50160)• Windows SQL Server2005 database, ODBCcompliant,support <strong>for</strong>multiple distributed serversand clientsEGX100gatewayModbus RS485Circuit breakerCompact NSXSensitive loads, requiring high availibility levelPower SCADAsoftware• Control an entireelectrical distributionsystem with up to 2,000devices• Web interfacing• Library of objects andpage templates• Calculations (MVA,Power Factor, MWh, etc.)86 87


Building managementApplication: commercial and industrial buildingsControl and monitor HVAC,lighting, security systems, andenergy consumptionBenefitsMeasure Reduce energy consumption Reduce energy costsTAC Vista 5• Server• Web stationOPCTAC Vista 5• WorkstationCameraVideobadging stationEthernet TCP/IPTAC I/NETOperatorstationMobilephonePDAInternetWebuserI want to reduce capital expenditures and operating costs,while making my building safer, more com<strong>for</strong>table, and moreenergy efficient. My ideal building management solution wouldbe user-friendly and web-accessible, providing access to thedifferent building systems from a single user interface.SolutionAdopt an intelligent buildingmanagement systemOur intelligent building management systems (iBMS) deliver reliable andefficient building management and significant energy savings. Built onopen, standards-based technology, our iBMS facilitate the integration ofbuilding systems into a single network, with easy management from a singlesoftware plat<strong>for</strong>m—even across multi-site organizations.A single local or web-based user interface provides a complete view of allsystems, including heating, ventilation, air conditioning, lighting, energyconsumption, access control, video surveillance, intrusion, fire and smokedetection, electrical distribution, power quality, and monitoring.We offer various intelligent building management systems and products,including TAC Vista, Satchwell and Andover Continuum.Our iBMS solutions enable significant energy efficiency through:• Schedule-based heating, ventilation, cooling, and lighting control• Occupancy-based environmental controls• Customizable energy reports and analysis• Advanced alarm management• Night setback, night ventilation purge• Optimal start/stop• Chiller/boiler plant optimization• Heating/cooling equipment lockout• Supply air temperature reset• Variable Air Volume (VAV) pressure and flow control• Outside air reduction• Economizer control• Electrical demand limits• Domestic hot water controlFor the userImprove yourbuilding andbusinessper<strong>for</strong>mance up to30% by:> Lowering energycosts and carbonemissions> Eliminatingunnecessarycomplexity by usinga single softwareplat<strong>for</strong>m <strong>for</strong> allbuilding controls> Cutting training,service, maintenance,and administrationcosts> Slashing capitalexpenditures by asmuch as 25%> Reducing ongoingoperating costs by asmuch as 36%Forprofessionals+ Lowerinstallation andongoing operatingcosts+ Streamlinedoperation, training,administration,maintenance, andserviceLonWorks IP routerLonWorksOur iBMS such asTAC Vista, Satchwelland AndoverContinuum offer themost open, scalableand IT-friendly buildingmanagement systemin the industry withTAC Xenta 911 TAC Xenta 511Comunication Device • Web server• LonTalk adapter • LonTalk adapterTAC Xenta 401 SeriesProgrammablecontrollerTAC Xenta 102 AXApplication SpecificController• VAVLonWorks IP routerSTR 250Room sensorTAC XentaI/O modulesTAC Xenta 280 SeriesProgrammable controllerTAC Xenta 913Integration Device• BACnet• Clipsal C-Bus• I/NET• M-BusTAC Xenta 100 SeriesApplication SpecificController• VAV• Fan Coil• Heat pump• Roof top unitTAC Xenta 300 SeriesProgrammablecontrollerSchneider ElectricVariable speed driveunique support <strong>for</strong> openprotocols & interfaces:• LON ® , BACnet ® ,Modbus ® OPC, ODBC• Ethernet, TCP/IP• SQL databases <strong>for</strong>an Open DatabasearchitectureTAC Xenta 700• Web server• Controller• LonTalk adapterTACXenta 913IntegrationDevice• TAC Xenta server• BACnet• Clipsal C-Bus• LonWorks• M-BusController LAN• ZigBee-ready wirelesssolution• SNMP, LDAP, TGMLgraphics/XMLNetworkcameraTAC Xenta 527• NetPlus router• Web serverTAC Xenta 913Integration Device7798Site controllerAccess control• SCU1284 -4 card readers• BACnet• Modbus• Clipsal C-Bus• LonWorks• M-BusProximity readersPelco DigitalSentryDigital VideoManagement SystemIntrusion alarm• SCU1200/80Intrusiondetector/alarms88 89


Photovoltaic cells—which capturethe sun’s energy—are the heartof any solar power system. Theintelligence of the system resides inthe electrical installation, however.It is the electrical installation that guaranteesthat the system works. It allows you to control asource of energy that fluctuates constantly due tochanging weather, detect any losses, and correctproblems, all with the end goal of supplying highqualityenergy.Our photovoltaic solutions respond to technicalissues while addressing processes to:> Guarantee ROI within 10 years> Streamline projects with convenient productplus-servicespackages> Ensure the reliability of the equipment installed> Simplify operation and optimize operating costs> Offer innovative functions and services> Protect the installation by adding remote safetyand monitoring systemsRenewable power generationChoose the solution that’s right <strong>for</strong> you> Use available rooftop space to install and operate solar panels (p. 92)> Boost your “green” image and save with photovoltaic energy (p. 94)> Supply a small group of remote, off-grid buildings with electricity (p. 96)9091


Renewable power generationApplication: commercial and farm buildings with roof surfaces < 500 square metersUse available rooftopspace to install and operatesolar panelsBenefitsMeasure Reduce energy consumption Reduce energy costsProjectsSouth of France: farm building gets rooftop solar panelsThe southern-facing rooftop of a farm outbuilding measuring just 147 squaremeters was the perfect location to install 105 175-watt solar panels covering atotal area of 139 square meters.Because total power was just over 18 kW, a three-phase connection to the gridwas installed.I want green certification <strong>for</strong> my farm.I would like to install rooftop solar panelson one of my outbuildings, but only if it isprofitable <strong>for</strong> the business.The total cost of the equipment, installation, and hook-up to the grid was€90,000.The installation is expected to generate 21,000 kWh per year, sold back to thegrid at €0.60 per kWh, <strong>for</strong> total annual revenue of more than €12,000.SolutionConvert the energy generated bysolar panels into alternating currentand connect to the three-phase gridThe system consists of photovoltaic panels that producebetween 30 kW and 50 kW of electricity by trans<strong>for</strong>ming solarenergy into direct electric current. This “convert, connect,protect” system is built around prefabricated, interconnectedpanels:• Panel strings are interconnected via junction boxes to poolthe electricity generated by the photovoltaic installation• An inverter then converts the direct current produced bythe panel strings into alternating current• Factory-assembled, pre-wired protection units ensure theinstallation is safe <strong>for</strong> both people and property.For the user> Helps businessesqualify <strong>for</strong> greencertification> ROI of less than10 years drivenby selling surpluspower back to thegrid (in countrieswhere incentives areoffered)> Clear in<strong>for</strong>mationthanks to SunEzyinverters, whichmonitor both theelectricity used andsold back to the gridForprofessionals+ SchneiderElectric supportto help you choosethe right solution+ All products,includingpanels, cables,and inverters,provided by asingle SchneiderElectric-approveddistributor+ Add on to theinstallation withoutmaking costlychanges+ MeetsenvironmentalstandardsSchneiderElectricofferPanel stringphase 1Junction boxeSunEzy BJ21Panel stringphase 2Panel stringphase 3Main boardOptionalinterface networkProtectionSunEzy CPSunEzy 4000Inverter DC/ACSunEzy 2800> Easy to upgradeto a buildingmanagement systemwithout changing theinstallationSunEzy inverters• SunEzy inverters coverpower from 2 kW to4.6 kW• They can beinterconnected usingSunEzy junction boxes (upto six strings)• SunEzy protectionsystems, which includelightning arresters, ensurethe installation is safeCommunication functionsare ensured:• via an LCD displayintegrated into eachinverter• via a PC installed with theSunEzy Control softwaredelivered with each inverter;the software offers an arrayof additional functions toprocess the data producedby each inverter- Display settings likepower, current, voltage,and frequency in graph<strong>for</strong>mat- Generate reportsSunEzy productscomply with thefollowing standards:• EMC Directive:EN 50081, EN 50082,EN 61000-3-2• Limitation of harmoniccurrent emissions (<strong>for</strong>currents under 16 A)• LV (Low Voltage)Directive: EN 50178• VDE GS label92 93


Renewable power generationApplication: buildings from 100 to 2,000 square metersBoost your “green” imageand save with photovoltaicenergyBenefitsMeasure Reduce energy consumption Reduce energy costsJunctionboxesModule array Module array Module arrayJunctionboxesInverterSunEzy 600EJunctionboxesInverterSunEzy 600EInverterSunEzy 600EOur company is known <strong>for</strong> environmentalawareness and advanced technology. We’d liketo build on that image and cut energy costs.Given our available rooftop space, solar panelsseem like a the natural choice.SolutionGenerate your own electricity withrooftop photovoltaic modulesThis solution is designed <strong>for</strong> three-phase electricity production.The photovoltaic modules are connected to the grid so you cansell surplus electricity back to the utility—usually at attractiverates—and all of the necessary devices and protective equipmentare housed out of sight in a facilities room.Schneider Electric provides:• Pre-wired, referenced junction boxes <strong>for</strong> connection to thephotovoltaic generator’s DC output• Pre-wired, referenced DC disconnection boxes• Dedicated DC/AC inverters synchronized with the utility grid• AC protection <strong>for</strong> connection to the gridAn iRio remote terminal unit monitors and transmits in<strong>for</strong>mationand tracks electricity production records. It can also be used <strong>for</strong>display and customer demonstrations, to show in real time thephotovoltaic production.For the user> Up to 20%savings• With incentives andbuy-back schemes,solar energy canoffset your electricitybill by up to 20%• ROI is less than10 years, and oftenfar less (6 to 8 years)> A smallerenvironmentalfootprint• Each kWhproduced shaves anaverage of 0.476 kgoff your building’scarbon footprint(average value inEurope)Forprofessionals+ Design• Free, easy-to-useSunEzy Designsoftware+ Installation• Junctionboxes and DCdisconnection boxespre-wired accordingto local standardsand rules• Limited partnumbers <strong>for</strong> easyselection andordering+ Maintenance• SunEzy inverterdisplay <strong>for</strong> easytesting• Included SunEzyControl software <strong>for</strong>inverter testing fromyour PCDC protectionenclosureOverviewof the monitoringsystemN1 L1 L2N3AC3-phaseprotectionenclosurePh1General publicdisplay (optional)Ph2Ph3DC protectionenclosureNNetwork interfaceSensor(optional)Site nr.1N2Local monitoringPC (optional)Site nr.2GSM/GPRSSite nr.3RemotemonitoringMaintenanceDC protectionenclosureL3Modbus RS485Plat<strong>for</strong>mInternetMonitoring bythe customer> A greener image• The system givesyou the data youneed to demonstrateyour commitment tothe environment• DIN-rail-mountediRio RTU transmitsall in<strong>for</strong>mation andmonitors buildingPV productionSunEzy DC/AC inverterfrom 2kWp to 5.4kWp• Compact• Trans<strong>for</strong>merless <strong>for</strong> highefficiency (94.5%)• High Maximum PowerPoint Tracker (MPPT)efficiency• 600E per<strong>for</strong>ms at750V/8.5A, with 3 MPPTs• IP65 pre-wireddisconnection enclosuresmeet local standards andrules• AC protection enclosuresavailable pre-wired oron-demandiRio RTU modularcommunicationsystem• Integrated web serversends in<strong>for</strong>mation by GSM,GPRS, Ethernet, or RS485• Optional additional cards<strong>for</strong> external inputs andoutputsSunEzy Designsoftware• Includes database ofphotovoltaic modules andSunEzy inverters• Recommends optimalPV generator architecture• Generates production<strong>for</strong>ecasts depending onlocation• Computes cable losses94 95


Renewable power generationApplication: off-grid buildingsSupply a small group ofremote, off-grid buildingswith electricityWe would like to provide electricityto a remote village in Africa. We are looking <strong>for</strong>the optimzl technical solution at the best price.BenefitsForprofessionals+ A single interface<strong>for</strong> centralizedmanagement andmonitoring+ Localpeople receivemaintenanceand operationtraining fromSchneider ElectricSurgearresterPRD 40RChargerXW MPPT60 A - 150 VMeasure Reduce energy consumption Reduce energy costsCircuit breakerC60 HDC 63 ASwitchINS 63Inverter DC/ACTrace TR1524230 V 50 Hz18 cellsContactorCT-2PKilowatt-hour meterEN40Circuit breaker+ earth fault 300 mADPN vigi 16 AGSMMonitoringiRIOFor the userHouse 1House 20SolutionInstall solar panels to provide thebuildings with their own independentenergy supplyThe system includes:• Solar panels with a total capacity of a few kWc• 1 Xantrex XW solar charge controller• A set of batteries to store several days’ worth of electricity• 1 Xantrex Trace TR1524 inverter• Circuit breakers to protect the solar installation and <strong>for</strong> eachbuilding• 1 GSM-equipped iRio unit <strong>for</strong> remote management of networkoperating schedule and monitoring of consumption, batteries,the charger, the solar panels, and the inverter• Surge protection devices <strong>for</strong> PC photovoltaic generators and<strong>for</strong> the AC part of the installation.> Totallyindependentelectricity supply> Local,independentmanagement of theinstallationProjectsMadagascar villagegets solar energyIn early 2009, solarpanels were installedin a mountain villagein Madagascar. Thevillage, which countsabout 20 houses,was too remote to beconnected up to themain grid. The goalwas to provide 50 W<strong>for</strong> each householdthree hours per day—a total of 1,000 W <strong>for</strong>the village or 3 kWhper day.According to asurvey conductedafter the project wascompleted, the localpopulation, whichhelped with the work,was satisfied withthe results. A team oftwo local electriciansreceived training fromSchneider ElectricMadagascar. Theydid the wiring in all ofthe houses and nowhandle maintenanceand repairs.Circuit breaker+ earth fault 30 mA20 W 15 W 15 WXantrex Trace TR1524inverter• Thermal per<strong>for</strong>manceallows full output powerto 50°C (122°F) withoutde-rating• Sophisticated, energysavingmulti-stage batterycharging algorithm- Charger turns off oncebatteries are fully charged,reducing energy bills- Battery life is prolongedbecause batteries are notcontinually held at floatvoltage• Power factor corrected(PFC) charging- Electrical draw is reducedby up to 30% less AC inputcurrent, while delivering thesame DC charging current- Better value andincreased savings withmaximum available ACpower <strong>for</strong> loads• Reducedelectrical noise andinterference with TVsand radios- Trace Series inverterchargersare FCC Class Bcompliant with necessaryEMI filtering componentsXantrex XW solarcharge controller• Photovoltaic (PV) chargecontroller that tracksthe electrical maximumpower point of a PV arrayto deliver the maximumavailable current <strong>for</strong>charging batteriesPRD 40R - 600 DC 2P• Surge arrester 600 DC:2 poles, Imax = 40A,In = 15ACircuitbreakerC120N 2PSurgearresterPRF1 12,596 97


<strong>Energy</strong> efficiency starts now.Our energy future depends on it.CheaperEach kWh not consumed equals 3 kWh our power plantsdon’t need to generateDemand response programs cost about half of typicalelectricity costsQuickerToday’s energy-efficiency technologies guarantee fast returnon investmentCleaner“Negawatt” produces zero environmental impactMore secure<strong>Energy</strong> efficiency is something we can control at home:it reduces our reliance on imports98


To find out moreSimply contact your usual Schneider Electricrepresentative.You can also find the necessary in<strong>for</strong>mation in thefollowing web sites:> www.contractors.schneider-electric.com> www.engineering.schneider-electric.comMake the most of your energySchneider Electric Industries SAS35, rue Joseph MonierF-92500 Rueil-MalmaisonFRANCETel. : +33 (0) 1 41 29 70 00www.schneider-electric.comDue to changes in standards and equipment, the specifications in this document are bindingonly after confirmation in writing by Schneider Electric.Schneider Electric Marketing : Fouzia Slaoui, Michel DalbeSchneider Electric Communication : Veronique FischerDesign: pemacoPhotos: Jupiterimages: Pixland - Xavier Renault - Gettyimages: Stockbyte, David De Lossy,Peter Augustin - Fotosearch: Corbis - Matton images: Antonello Turchetti, Andersen Ross- Schneider electric08/2009