12.07.2015 Views

DVU and DVU-C - Systemair

DVU and DVU-C - Systemair

DVU and DVU-C - Systemair

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2| <strong>DVU</strong> <strong>and</strong> <strong>DVU</strong>-C<strong>DVU</strong> Cooling UnitAHU N o 07.02.339DANVENT DV10-240, TIME 10-40<strong>DVU</strong> is an air cooling system for TIME ec <strong>and</strong> DV air h<strong>and</strong>ling units. It is completed <strong>and</strong> tested from factory. It has a speedadjustable compressor; this makes it possible to adjust the cooling capacity exactly, which gives excellent comfort.Frequency converter <strong>and</strong> control are integrated.+Unit size TIME ec/DV-10 TIME ec/DV-15 TIME ec/DV-20 TIME ec/DV-25 TIME ec/DV-30 TIME ec/DV-40Recommended air flow m 3 /s 0,6 0,8 1,3 1,8 1,9 2,7Cooling capacity kW 11 15 23 32 35 49EER total at max cooling capacity 2,7 2,5 2,9 2,8 2,9 2,9Outdoor conditions: 32 °C/40% RH, extract air 25 °C/50% RH <strong>and</strong> supply air temperature 18 °C.<strong>DVU</strong> cooling unit• 6 sizes 2.150-9.700 m 3 /h,0,6-2,7 m 3 /s• Stepless control of cooling capacity• Cooling capacity <strong>and</strong> energy consumptionoptimized during operation• Separate control– independent simple <strong>and</strong> flexible• Fully mounted from factory• Cooling capacity up to 49 kW


<strong>DVU</strong> <strong>and</strong> <strong>DVU</strong>-C |3<strong>DVU</strong>-C Cooling UnitAHU N o 07.02.339DANVENT DV10-240, TIME 10-40The <strong>DVU</strong>-C is a unit with a rotary heat exchanger joined together with a stepless regulated air cooling system. The joining of thetwo gives the advantage of free cooling when the extract air temperature is below the outdoor air temperature. Consequently, asubstantial part of the cooling capacity is gained almost for free, <strong>and</strong> therefore a considerably smaller cooling unit may be required.+Unit size DV-10 DV-15 DV-20 DV-25 DV-30 DV-40Recommended air flow m 3 /s 0,8 1,2 1,6 2,0 2,5 3,2Cooling capacity kW 18 27 37 48 58 76EER total at max cooling capacity 4,6 4,4 4,7 4,4 4,9 4,5Outdoor conditions: 32 °C/40% RH, extract air 25 °C/50% RH <strong>and</strong> supply air temperature 18 °C.<strong>DVU</strong>-C cooling unit with cooling recovery• 6 sizes from 2.900-11.500 m 3 /h, 0,8-3,2 m 3 /s• “Free cooling capacity”• Stepless control of cooling capacity• Cooling capacity <strong>and</strong> energy consumptionoptimized during operation• Separate control – independent simple <strong>and</strong> flexible• Fully mounted from factory• Cooling up to 76 kW• Short length


4| <strong>DVU</strong> <strong>and</strong> <strong>DVU</strong>-CCooling Capacity <strong>DVU</strong>Cooling capacity (Example: Unit size <strong>DVU</strong>-30)<strong>DVU</strong>60 kW50 kW40 kW30 kW20 kW10 kW25 °C /50% RH28 °C /50% RH30 °C /45% RH32 °C /40% RHOutdoor conditions18,0 18,0 18,7 20,3 Supply air temperature °C24,0 33,0 37,2 38,5 Cooling capacity kW5,2 9,0 11,5 11,8 Power consumption kW4,6 3,7 3,2 3,3 EER, totalPerformance example: DV-30 with 2,5 m 3 /s. Extract air 25 °C/50% RH.


<strong>DVU</strong> <strong>and</strong> <strong>DVU</strong>-C |5Cooling Capacity <strong>DVU</strong>-CCooling capacity (Example: Unit size <strong>DVU</strong>-C-30)<strong>DVU</strong>Rotary heat exchanger60 kW50 kW40 kW30 kW20 kW10 kW25 °C /50% RH28 °C /50% RH30 °C /45% RH32 °C /40% RHOutdoor conditions18,0 18,0 18,0 18,0 Supply air temperature °C24,0 42,0 49,0 55,0 Cooling capacity kW5,2 6,3 7,4 8,7 Power consumption kW4,6 6,6 6,6 6,3 EER, totalPerformance example: DV-30 with 2,5 m 3 /s. Extract air 25 °C/50% RH.


6| <strong>DVU</strong> <strong>and</strong> <strong>DVU</strong>-CCalculation<strong>Systemair</strong>CAD• Can be downloaded fromwww.systemair.dk• High technicaldocumentation• All important figures• System description• Calculations


<strong>DVU</strong> <strong>and</strong> <strong>DVU</strong>-C |7DimensionsHHLWLW<strong>DVU</strong> W H L<strong>DVU</strong>-10 970 970 970<strong>DVU</strong>-15 1120 1120 1120<strong>DVU</strong>-20 1270 1270 1120<strong>DVU</strong>-25 1420 1420 1270<strong>DVU</strong>-30 1570 1570 1270<strong>DVU</strong>-40 1720 1720 1270<strong>DVU</strong>-C W H L<strong>DVU</strong>-C-10 970 970 1270<strong>DVU</strong>-C-15 1120 1120 1270<strong>DVU</strong>-C-20 1270 1270 1270<strong>DVU</strong>-C-25 1420 1420 1270<strong>DVU</strong>-C-30 1570 1570 1270<strong>DVU</strong>-C-40 1720 1720 1420


<strong>Systemair</strong> A/SVed Milepælen 7DK-8361 Hasselager<strong>DVU</strong>_<strong>DVU</strong>_C_uk_03_2012-V1-90934302Tel. +45 87 38 75 00mail@systemair.dkwww.systemair.dk