01.12.2012 Views

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TEST & MEASUREMENT<br />

<strong>RENTAL</strong> <strong>SOLUTIONS</strong> <strong>GUIDE</strong> <strong>2007</strong><br />

VOLUME 32 ISSUE 12<br />

>ELEC<strong>TR</strong>ONICS & DATA >ELEC<strong>TR</strong>ICAL POWER >GENERAL INDUS<strong>TR</strong>IAL >ENVIRONMENTAL >CALIBRATION


TEST & MEASUREMENT <strong>RENTAL</strong> <strong>SOLUTIONS</strong><br />

SpecialiSed<br />

equipment<br />

rental<br />

rental<br />

purchaSe<br />

OptiOn<br />

cOnvenient<br />

Office<br />

lOcatiOnS<br />

delivery &<br />

Setup<br />

expert<br />

advice<br />

frOm 1<br />

day tO<br />

lOng<br />

term<br />

calibratiOn<br />

ServiceS


WELCOME<br />

We are pleased to bring you the <strong>2007</strong> edition of our<br />

Rental Solutions Guide, showcasing our extensive<br />

inventory of test and measurement equipment covering<br />

Data Communications, RF Telecommunications,<br />

Electrical Power, Environmental and General Industrial.<br />

TechRentals have been helping solve test and<br />

measurement problems for over 32 years and in the<br />

past 12 months our organisation has seen significant<br />

changes, which have only enhanced our ability to assist.<br />

New offices in regional Australia in places like Devonport<br />

and Karratha, plus new locations in New Zealand<br />

and Malaysia are helping us deliver our solutions<br />

to the world.<br />

This new edition of our guide includes numerous<br />

new products and models, also highlighting our<br />

equipment calibration capabilities via our sister<br />

company VMS; Australia’s leading group of NATA<br />

certified calibration laboratories.<br />

We look forward to assisting you with your test and<br />

measurement needs and hope you will find this guide<br />

a useful resource.<br />

The TechRentals Team<br />

TechRentals Information ii<br />

Office Locations iv<br />

Quick Find Solution Guide vi<br />

>ELEC<strong>TR</strong>ONICS & DATA 1<br />

General Electronic Test Equipment 2<br />

RF & Microwave 13<br />

Low Frequency 26<br />

TV Test Equipment 27<br />

Data, Network<br />

& Telecommunications 28<br />

Cable/Pipe Testers & Locators 36<br />

>ELEC<strong>TR</strong>ICAL POWER 39<br />

Magnetic Field Meters 40<br />

Insulation & Resistance Testers 41<br />

Power Quality Analysers 48<br />

Projection Relay Testing Systems 57<br />

AC/DC Hi Pot Testers 59<br />

Electrical Transducers 60<br />

Current Injectors - Primary & Secondary 65<br />

Power Line Conditioners & UPS 66<br />

AC Power 68<br />

>GENERAL<br />

INDUS<strong>TR</strong>IAL 69<br />

Data Acquisition & Recording 70<br />

Physical Measurement 77<br />

Non-Destructive Testing 88<br />

General Industrial 94<br />

Temperature<br />

& Humidity Measurement 102<br />

Security Equipment 106<br />

>ENVIRONMENTAL 109<br />

Flow Meters 110<br />

Air Conditioning<br />

& Air Quality - HVAC & IAQ 113<br />

Occupational Health & Safety 119<br />

Gas Analysis & Monitoring 123<br />

General Environment 128<br />

Laboratory 131<br />

>CALIBRATION 133<br />

General Index 135


TECH<strong>RENTAL</strong>S<br />

prOviding SOlutiOnS<br />

For 32 years, TECH<strong>RENTAL</strong>S has been providing rental<br />

solutions across Australasia. When you need to test,<br />

measure or record, we will assist with expert advice, flexible<br />

rental options and the right technology to get the job done.<br />

When you need the job done right, first time, talk to us.<br />

Why yOu ShOuld uSe techrentalS<br />

cOnvenient lOcatiOnS<br />

Our customers have access to over 30 <strong>TR</strong> <strong>Corporation</strong> locations across Australia,<br />

New Zealand and Malaysia. Locations range from small technical offices in remote<br />

areas such as Karratha in the mining hub of Western Australia to sophisticated<br />

calibration laboratories in Sydney and Brisbane, and our fully equipped <strong>TR</strong> <strong>Corporation</strong><br />

headquarters in Melbourne.<br />

vaSt inventOry Of SpecialiSed equipment<br />

With more than 10,000 items in stock, we’re bound to have the gear you need, no<br />

matter what your industry or project. New products are continually being added to our<br />

inventory as technology evolves. Local government regulations may apply to the use of<br />

some equipment in this catalogue, please contact your local office for more information.<br />

the lateSt prOductS frOm WOrld claSS brandS<br />

We stock the latest gear from leading manufacturers including FLUKE, AGILENT,<br />

HIOKI, ANRITSU, MEGGER, YOKOGAWA and more.<br />

expert advice<br />

Our team of technical sales people are highly experienced, most with extensive industry<br />

backgrounds. They’re friendly, reliable and knowledgeable with a “can do” attitude.<br />

Simple quOting<br />

Our rapid quoting system means you are only a phone call or “mouse click” away.<br />

Get online and select the equipment you need, or call and discuss your specific<br />

requirements with our team for a quick and accurate estimate.<br />

flexible rental termS<br />

Whether it’s for a day, a week, a year, or you wish to rent-to-own, TECH<strong>RENTAL</strong>S can<br />

assist. And if your project is extended, it’s no problem. Simply call and we’ll amend the<br />

rental contract.<br />

reSpOnSive delivery & Setup<br />

You need equipment fast and at the right place, at the right time, and ready to go.<br />

Equipment is delivered in purpose-built protective containers, in tiptop condition and<br />

with easy to understand instructions.<br />

OptiOnS<br />

Other options are available to complement your rental needs including data download,<br />

trained operators to manage the task for you, customised equipment programming and<br />

even total asset management.<br />

nO riSk guarantee<br />

And if the unusual occurs and the gear isn’t up to the job, return it within 24 hours to<br />

receive a refund on the rental charge.<br />

part Of tr cOrpOratiOn<br />

In 2005, TechRentals became part of a larger family with the formation of <strong>TR</strong><br />

<strong>Corporation</strong>. Each subsidiary is a leading brand offering a specialised technology<br />

solution for industry. Our group capabilities now include radio communications, audio<br />

visual & business equipment, calibration, wireless connectivity solutions and mining<br />

communications. Our customers range from mining companies in Poland and Chile<br />

to a small electrical contractor in Christchurch, New Zealand - making us a truly global<br />

technology supplier.


delivering<br />

benefitS<br />

Whether you’re part of<br />

a major multinational<br />

or a small-to-medium<br />

enterprise, equipment<br />

rental makes good<br />

business sense offering<br />

a range of economic and<br />

practical benefits.<br />

Avoid the headaches and<br />

talk to us.<br />

ECONOMICAL<br />

FLEXIBLE<br />

ACCESSIBLE<br />

Free up capital<br />

Recover costs<br />

more quickly<br />

Control costs<br />

more efficiently<br />

Eliminate running costs<br />

Conduct product<br />

research before<br />

purchases<br />

Apply new technologies<br />

& avoid obsolescence<br />

Respond to<br />

sudden demands<br />

Seek help from<br />

the experts<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

Why yOu ShOuld rent<br />

financial benefitS<br />

CONSERVE YOUR CApITAL: Industrial equipment is expensive and can spend much<br />

of its time unused, collecting dust and delivering no return on investment. By renting<br />

the equipment that you only need occasionally, you can release your organisation’s<br />

capital to invest in other parts of the business.<br />

RECOVER YOUR COSTS: Generally, rental payments are fully tax deductible, and<br />

the expense can be recouped far quicker than tax allowances for ongoing asset<br />

depreciation.<br />

S<strong>TR</strong>EAMLINE YOUR ACCOUNTS: Equipment is often required for a particular client,<br />

project or location. Renting allows you to control your financials more effectively and<br />

simplifies the process of allocating costs to internal departments or third-parties.<br />

WIpE OUT RUNNING COSTS: The expense of maintaining, calibrating and<br />

warehousing equipment can be high. By renting equipment, you avoid these costs and<br />

potentially free-up valuable space within your premises.<br />

OperatiOnal benefitS<br />

<strong>TR</strong>Y bEFORE YOU bUY: It’s not always clear which equipment make and model will<br />

fulfil your requirements. A short term rental can give you the hands-on experience you<br />

need to guide purchase decisions.<br />

KEEp Up WITH THE TIMES: businesses are constantly evolving to keep pace with<br />

new technologies. Rental allows you to update your equipment in line with other<br />

business and industry changes and avoid the risk of accommodating costly dinosaurs.<br />

CATER TO THE UNExpECTED: At peak periods or when essential equipment breaks<br />

down, rental can put the necessary equipment in your hands ensuring seamless<br />

operations.<br />

REFER TO THE ExpERTS: Should you experience difficulties with rented equipment,<br />

it’s not your problem. Simply call TechRentals for free professional equipment advice<br />

and support.<br />

OptiOn tO OWn<br />

TechRentals offers approved business<br />

customers a unique rental solution<br />

with option to own schemes.<br />

Whether it’s the latest power analyser<br />

or a humidity chamber, the option of<br />

ownership offers flexibility should a<br />

stopgap measure turn into a long term<br />

or permanent need.<br />

After a mutually agreed minimum<br />

rental period (typically 12 months),<br />

the equipment may be purchased<br />

by paying an amount equal to one<br />

month’s rental. After a specified<br />

number of payments, the equipment<br />

is yours!<br />

For more information about option to<br />

own schemes, please call your local<br />

TECH<strong>RENTAL</strong>S office.<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my<br />

WHY BUY WHEN YOU CAN RENT?


LOCATIONS<br />

v<br />

With locations across<br />

Australia, New<br />

Zealand and Malaysia,<br />

TECH<strong>RENTAL</strong>S have<br />

all your Test and<br />

Measurement problems<br />

covered<br />

auStralia<br />

adelaide<br />

81-83 Stephens Avenue<br />

Torrensville South Australia 5031<br />

P +61 8 8302 8800<br />

F +61 8 8302 8899<br />

briSbane<br />

Unit 1 46 Longland Street<br />

Newstead Queensland 4006<br />

P +61 7 3850 7700<br />

F +61 7 3850 7799<br />

darWin<br />

Unit 3 101 Coonawarra Road<br />

Winnellie Northern Territory 0820<br />

p +61 8 8947 2860<br />

F +61 8 8947 2901<br />

devOnpOrt<br />

53 Don Road<br />

Devonport Tasmania 7310<br />

p +61 3 6422 6000<br />

F +61 3 6424 3994<br />

gOld cOaSt<br />

103-105 Spencer Road<br />

Nerang Queensland 4211<br />

p +61 7 5596 3451<br />

F +61 7 5596 4119<br />

karratha<br />

33B Gawthorne Drive<br />

Karratha Western Australia 6714<br />

P +61 8 9185 6871<br />

F +61 8 9441 3999<br />

melbOurne<br />

6 Joseph Street<br />

blackburn North Victoria 3130<br />

P +61 3 9896 3000<br />

F +61 3 9896 3099<br />

neWcaStle<br />

Unit 2 1 Hartley Drive<br />

Thornton New South Wales 2322<br />

p +61 2 4966 5910<br />

F +61 2 4966 3586<br />

perth<br />

122 Kewdale Road<br />

Kewdale Western Australia 6105<br />

p +61 8 9441 3900<br />

F +61 8 9441 3999<br />

pOrt melbOurne<br />

Unit 11 484 Graham Street<br />

Port Melbourne Victoria 3207<br />

P +61 3 9896 3000<br />

F +61 3 9896 3099<br />

Sydney<br />

Metro Centre Unit 13<br />

38-46 South Street<br />

Rydalmere New South Wales 2116<br />

P +61 2 9933 1100<br />

F +61 2 9933 1199<br />

tOWnSville<br />

Unit 8 15-17 Castlemaine Street<br />

Kirwin Queensland 4817<br />

p +61 7 4773 7788<br />

F +61 7 4723 5397<br />

vmS - calibratiOn,<br />

repair & Service<br />

melbOurne<br />

6 Joseph Street<br />

blackburn North Victoria 3130<br />

P +61 3 9896 3000<br />

F +61 3 9896 3099<br />

cOOperS plainS<br />

Unit 1&4 30 Lensworth Street<br />

Coopers plains Queensland 4108<br />

p +61 7 3344 1866<br />

F +61 7 3344 1744<br />

milperra<br />

Unit 34 244 Horsley Road<br />

Milperra New South Wales 2214<br />

P +61 2 9771 9300<br />

F +61 2 9711 9600


neW zealand malaySia<br />

auckland<br />

669 Great South Road<br />

penrose Auckland New Zealand<br />

p +64 9 589 2030<br />

F +64 9 589 2031<br />

hamiltOn<br />

4/11 pukete Road<br />

Te Rapa Hamilton New Zealand<br />

p +64 7 849 0674<br />

F +64 7 849 0676<br />

WellingtOn<br />

71 Hutt Road<br />

Wellington New Zealand<br />

p +64 4 384 4833<br />

F +64 4 384 4677<br />

chriStchurch<br />

540 Wairakei Road<br />

Christchurch New Zealand<br />

p +64 3 338 1188<br />

F +64 3 338 7100<br />

Other tr cOrpOratiOn<br />

lOcatiOnS in neW zealand:<br />

bearcOm<br />

cOmmunicatiOnS<br />

Auckland<br />

Hamilton<br />

Wellington<br />

Christchurch<br />

vidcOm<br />

audiO viSual<br />

Auckland<br />

Tauranga<br />

Hamilton<br />

Rotorua<br />

Christchurch<br />

Queenstown<br />

Dunedin<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

kuala lumpur<br />

38 Jalan pJS 11/3 bandar Sunwa<br />

46150 petaling Jaya<br />

Selangor Darul Ehsan Malaysia<br />

P +60 3 5632 1135<br />

F +60 3 5632 5409<br />

penang<br />

b-4-23 Krystal point<br />

303 Jalan Sultan Azlan Shah<br />

Sungai Nibong<br />

11900 Penang Malaysia<br />

p +604 642 6318<br />

F +604 642 2035<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

LOCATIONS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my v


QUICK FIND SOLUTION <strong>GUIDE</strong><br />

v<br />

agriculture maintenance<br />

& management<br />

chemical analysis 131<br />

data logging 70<br />

environmental testing 123<br />

humidity measurement 113-114<br />

light & UV measurement 119<br />

liquid & gas flow measurement 110<br />

microscopes 82<br />

pressure measurement 77, 83<br />

temperature measurement 102<br />

weather recording 118<br />

air cOnditiOning & refrigeratiOn -<br />

maintenance<br />

air conditioning system balancing 118<br />

air flow measurement 113-114<br />

air quality testing 113-114<br />

data logging 70<br />

dust detection 113-114<br />

gas analysis & monitoring 123<br />

gas leakage detectors 118<br />

humidity measurement 77, 83<br />

liquid & gas flow measurement 110<br />

noise analysis 120<br />

pressure measurement 82-83<br />

temperature measurement 102<br />

temperature/humidity/barometric<br />

recording 102<br />

vibration measurement 88<br />

autOmOtive engineering & deSign<br />

air flow measurement 113-114<br />

air quality testing 113-114<br />

data logging 70<br />

dc power supplies 7<br />

electrical insulation testing 41<br />

endoscopes 79<br />

force gauges 84<br />

gas analysis & monitoring 123<br />

high speed video recording 82<br />

humidity measurement & recording 102<br />

instrumentation amplifiers 73<br />

light & UV measurement 119<br />

liquid & gas flow measurements 110<br />

microscopes 82<br />

noise analysis 120<br />

non-destructive testing (NDT) 88<br />

pressure & vacuum<br />

measurement 82-83<br />

tachometers & stroboscopes 78<br />

temperature measurement<br />

& recording 102<br />

thermal imaging camera 104<br />

vibration measurement 88<br />

building & cOnStructiOn<br />

ac power sources/inverters<br />

/generators 68<br />

air flow measurement 113-114<br />

air quality testing 113-114<br />

cable & pipe location 36<br />

cable integrity testing 36<br />

concrete testing 90-93<br />

distance measurement 78<br />

electrical insulation testing 41<br />

endoscopes 79<br />

gas analysis & monitoring 123<br />

hardness testing 93<br />

humidity & moisture measurement 105<br />

light & UV measurement 119<br />

liquid & gas flow measurement 110<br />

load measurement 85<br />

noise measurement 120<br />

non-destructive testing (NDT) 88<br />

pressure measurement 82-83<br />

security equipment 106<br />

temperature/humidity/barometric<br />

recorders 102<br />

thermal imaging cameras 104<br />

vibration measurement 88<br />

weather recording 118<br />

buSineSS & Office equipment<br />

ac generators & UpS 66<br />

network test equipment 29<br />

security equipment 106<br />

chemical analySiS<br />

air quality measurement 113-114<br />

ground water logging 128<br />

salinity testing 128<br />

spectrophotometers 131<br />

water quality testing 128<br />

data cOmmunicatiOnS<br />

ac generators & UpS 66<br />

dc power supplies 7<br />

fibre optics cable testing & splicing 33<br />

LAN analysis and management 29<br />

LAN cable testing 32<br />

WAN analysis & management 31<br />

defence pOlice fire & emergency<br />

ac generators & UpS 66<br />

ac power sources/inverters/<br />

generators 68<br />

air flow measurement 113-114<br />

air quality 113-114<br />

cable pipe testing & location 36<br />

data logging 70<br />

endoscopes 79<br />

environmental - testing 123<br />

gas analysis & monitoring 123<br />

high speed video capture 82<br />

light & UV measurement 119<br />

microscopes 82<br />

noise & vibraton analysis 120<br />

non-destructive testing (NDT) 88<br />

sound signal analysis 119<br />

spectroscopy 131<br />

temperature measurement 102<br />

thermal imaging cameras 104<br />

TV test equipment 27<br />

weather recording 118<br />

educatiOn<br />

security & surveillance equipment 106<br />

electrical – induStrial & dOmeStic<br />

ac generators & UpS 66<br />

ac power analysis & recording 40<br />

ac power sources/inverters/<br />

generators 68<br />

cable pipe testing & location 36<br />

current injection 64<br />

data logging 70<br />

dc power supplies 7<br />

digital storage oscilloscope 2<br />

electrical calibrators 9<br />

electrical transducers 60<br />

field strength measurement 19<br />

general electrical testing 63<br />

high voltage testing 4, 59<br />

instrumentation amplifiers 73<br />

insulation testing 40<br />

magnetic field measurement 40<br />

multimeters & electrometers 5<br />

power transformers 67<br />

temperature measurement 102<br />

thermal imaging cameras 104<br />

voltage current recording 76<br />

emergency ServiceS<br />

ac generators & UpS 66<br />

ac power sources/inverters/<br />

generators 68<br />

air flow measurement 113-114<br />

air quality 113-114<br />

cable pipe testing & location 36<br />

data logging 70<br />

endoscopes 79<br />

environmental - testing 123<br />

gas analysis & monitoring 123<br />

high speed video capture 82<br />

light & UV measurement 119<br />

microscopes 82<br />

noise & vibraton analysis 120<br />

non-destructive testing (NDT) 88<br />

RF & microwave testing equipment 13<br />

sound signal analysis 119<br />

spectroscopy 131<br />

temperature measurement 102<br />

thermal imaging cameras 104<br />

TV test equipment 27<br />

weather recording 118<br />

envirOnmental teSting<br />

air flow measurement 113-114<br />

air quality measurement 113-114<br />

data logging 70<br />

electrochemistry 128<br />

gas analysis & monitoring 123<br />

humidity & moisture measurement 105<br />

light & UV measurement 119<br />

liquid & gas flow measurement 110<br />

noise & sound 120<br />

spectroscopy 131<br />

temperature measurement 102<br />

temperature/humidity/barometric<br />

recorders 102<br />

thermal imaging cameras 104<br />

vibration analysis 88<br />

water quality testing 128<br />

weather recording stations 118<br />

event management<br />

metal detectors 107<br />

security & surveillance 106


fOOd manufacturing<br />

air quality monitoring 113-114<br />

endoscopes 79<br />

high speed video capture 82<br />

humidity measurement & logging 102<br />

metal detectors 106<br />

moisture meters 105<br />

process control test equipment 94-95<br />

scales & balances 87<br />

temperature measurement<br />

& logging 102<br />

water quality testing 128<br />

gaS induStry<br />

cable pipe testing & location 36<br />

data logging 70<br />

gas analysis & monitoring 123<br />

high speed video capture 82<br />

humidity & moisture measurement 105<br />

liquid & gas flow measurement 110<br />

non-destructive testing (NDT) 88<br />

OH&S & environmental testing<br />

- general 122<br />

pressure vacuum gauges<br />

& recorders 82-83<br />

spectroscopy 131<br />

thermal imaging cameras 104<br />

voltage current recording 76<br />

general electrOnicS teSt equipment<br />

data logging 70<br />

dc power supplies 7<br />

digital storage oscilloscopes 2<br />

distortion analysers 26<br />

electrical calibrators 9<br />

EMC test equipment 21<br />

field strength meters & antennas 19<br />

frequency counters 12<br />

frequency response analysers 10<br />

function generators 8<br />

instrumentation amplifiers 73<br />

LCR meters 9<br />

LF signal generators 26<br />

logic/analysers/testers 10<br />

memory recorders 73<br />

multimeters & electrometers 5<br />

non-storage oscilloscopes 3<br />

probes & accessories 4<br />

PROM programmers 10<br />

pulse generators 9<br />

strip chart recorders 76<br />

tape recorders 76<br />

TV test equipment 27<br />

ultrasonic baths 100<br />

voltage current recorders 76<br />

health & Safety<br />

air flow measurement 113-114<br />

air quality measurement 113-114<br />

data logging 70<br />

electrical insulation testing 41<br />

electrochemistry 128<br />

gas analysis & monitoring 123<br />

light & UV measurement<br />

magnetic field measurement<br />

119<br />

– Gauss Tesla<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

40<br />

noise & sound analysis 120<br />

OH&S & environmental compliance<br />

testing 122<br />

vibration analysis 88<br />

water quality measurement 128<br />

it departmentS<br />

ac generators & UpS 66<br />

air conditioning testing 113-114<br />

air flow measurement 113-114<br />

cable location 36<br />

data comms test equipment<br />

– LAN/WAN 31<br />

security & surveillance equipment 106<br />

temperature measurement<br />

& recording 102<br />

lOcal gOvernment<br />

ac generators & UpS 66<br />

air flow measurement 113-114<br />

air quality testing 113-114<br />

cable pipe testing & location 36<br />

concrete testing equipment 90<br />

data logging 70<br />

electrical insulation testing 41<br />

electrical testers 63<br />

electrochemistry 128<br />

gas analysis 123<br />

LAN analysis & monitoring 29<br />

LAN/WAN analysers 31<br />

light & UV measurement 119<br />

magnetic field meters 40<br />

noise & sound analysis 120<br />

OH&S & environmental equipment 122<br />

temperature measurement 102<br />

thermal imaging cameras 104<br />

vibration analysis 88<br />

WAN analysers 31<br />

water quality testing 128<br />

manufacturing & prOceSS induStry<br />

ac generators & UpS 66<br />

cable pipe testing & location 36<br />

data logging 70<br />

distance mesurement 78<br />

endoscopes 79<br />

gloss mesurement 90<br />

hardness testing 93<br />

high speed video capture 82<br />

humidity & moisture measurement 105<br />

inclinometers 84<br />

light & UV measurement 119<br />

liquid & gas flow mesurement 110<br />

materials testing 86, 128, 131<br />

memory recorders 73<br />

microscopes 82<br />

noise & sound analysis 120<br />

non-storage oscilloscopes 3<br />

OH&S & environmental - general 122<br />

position transducers 84<br />

pressure & humidity<br />

measurement 77, 83<br />

pressure vacuum measurement 82-83<br />

PROM programmers 10<br />

scales & balances 87<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

strip chart recorders 76<br />

tachometers/stroboscopes 78<br />

tape recorders 76<br />

temperature measurement 102<br />

temperature/humidity recorders 102<br />

thermal imaging cameras 104<br />

vibration analysis 88<br />

marine<br />

dc & ac power testing 40<br />

endoscopes 79<br />

liquid & gas flow measurement 110<br />

non-destructive testing (NDT) 88<br />

see ‘general electronics test equipment’<br />

mining & explOratiOn<br />

ac generators & UpS 66<br />

air flow measurement 113-114<br />

air quality measurement 113-114<br />

cable pipe testers & locators 36<br />

data logging 70<br />

dc power supplies 7<br />

distance measurement & surveying 78<br />

electrochemistry 128<br />

endoscopes 79<br />

force measurement 84<br />

gas analysis 123<br />

high speed video capture 82<br />

humidity & moisture measurement 105<br />

inclinometers 84<br />

light & UV measurement 119<br />

liquid & gas flow measurement 110<br />

load measurement 85<br />

Logic analysers & testers 10<br />

memory recorders 73<br />

microscopes 82<br />

noise & sound analysis 120<br />

non-destructive testing (NDT) 88<br />

OH&S & environment compliance<br />

testing 122<br />

power analysis & recording 40<br />

pressure & humidity<br />

measurement 77, 83<br />

pressure vacuum gauges<br />

/recorders 82-83<br />

protection relay testing 57<br />

RF amplifiers 13<br />

RF signal generators 13<br />

RF sweep generators 13<br />

spectroscopy 131<br />

strip chart recorders 76<br />

telecommunications testing 21<br />

temperature measurement 102<br />

temperature/humidity/barometric<br />

measurement 102<br />

thermal imaging cameras 104<br />

vibration & alignment analysis 88<br />

weather monitoring & recording 118<br />

nOn-deStructive teSting<br />

acceleration measurement 88<br />

cover meters 92<br />

gloss measurement 90<br />

hardness testing 93<br />

liquid & gas flow measurement 110<br />

QUICK FIND SOLUTION <strong>GUIDE</strong><br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my v


QUICK FIND SOLUTION <strong>GUIDE</strong><br />

v<br />

shock testing 88<br />

thickness measurement 90<br />

vibration measurement 88<br />

OccupatiOnal health & Safety<br />

air flow measurement 113-114<br />

air quality measurement 113-114<br />

data logging 70<br />

electrical insultation testing 41<br />

electrochemistry 128<br />

gas analysis & monitoring 123<br />

light & UV measurement 119<br />

magnetic field measurement<br />

– Gauss Tesla 40<br />

noise & sound analysis 120<br />

OH&S & environment compliance<br />

testing 122<br />

vibration analysis 88<br />

water quality measurement 128<br />

petrOchemical<br />

data logging 70<br />

electrochemistry 128<br />

force measurement 84<br />

gas analysis & monitoring 123<br />

high speed video capture 82<br />

liquid & gas flow measurement 110<br />

load measurement 85<br />

memory recorders 73<br />

microscopes 82<br />

non-destructive testing (NDT) 88<br />

pressure & humidity<br />

measurement 77, 83<br />

pressure vacuum gauges<br />

/recorders 82-83<br />

strip chart recorders 76<br />

tachometers/stroboscopes 78<br />

temperature measurement 102<br />

thermal imaging cameras 104<br />

vibration & alignment analysis 88<br />

water quality measurement 128<br />

plumbing & gaSfitting<br />

see ‘water waste water & plumbing’ section<br />

pOWer generatiOn & diStributiOn<br />

cable pipe testers & locators 36<br />

combustion gas analysis<br />

& monitoring 124-125<br />

current injectors 64<br />

data logging 70<br />

distance measurement & surveying 78<br />

endoscopes 79<br />

force measurement 84<br />

hi pot testing 59<br />

high speed video capture 82<br />

humidity & moisture measurement 105<br />

inclinometers 84<br />

insulating testing 41<br />

LCR meters 9<br />

liquid & gas flow measurement 110<br />

load measurement 85<br />

magnetic field measurement<br />

– Gauss Tesla 40<br />

noise & sound analysis 120<br />

non-destructive testing (NDT) 88<br />

power analysis & recording 40<br />

protection relay testing 57<br />

strip chart recorders 76<br />

tachometers/stroboscopes 78<br />

temperature/humidity/barometric<br />

measurement 102<br />

thermal imaging cameras 104<br />

vibration & alignment analysis 88<br />

voltage current recorders 76<br />

weather monitoring & recording 118<br />

quality cOntrOl<br />

see ‘manufacturing & process industry’ section<br />

refrigeratiOn<br />

see ‘air conditioning & refrigeration’ section<br />

retail<br />

security & surveillance equipment 106<br />

rf & micrOWave<br />

communications test sets 21<br />

EMC test equipment 21<br />

field strength meters & antennas 19<br />

filters 26<br />

frequency counters 12<br />

logic analysers & testers 10<br />

modulation meters 20<br />

power meters 22<br />

RF amplifiers 13<br />

RF signal generators 13<br />

RF sweep generators 13<br />

spectrum analysers - high frequency 14<br />

telecommunications testing 21<br />

TV test equipment 27<br />

rOad rail & civil cOnStructiOn<br />

ac power sources/inverters<br />

/generators 68<br />

air flow measurement 113-114<br />

air quality measurement 113-114<br />

cable pipe testing & location 36<br />

concrete testing equipment 90-92<br />

dc power supplies 7<br />

distance measurement & surveying 78<br />

electrochemistry 128<br />

force measurement 84<br />

gas analysis & monitoring 123<br />

hardness testers 93<br />

inclinometers 84<br />

load measurement 85<br />

magnetic field measurement<br />

– Gauss Tesla 40<br />

noise & sound analysis 120<br />

non-destructive testing (NDT) 88<br />

power analysis & recording 40<br />

vibration & alignment analysis 88<br />

water quality testing 128<br />

weather monitoring & recording 118<br />

Security & crOWd crOntrOl<br />

bug detectors 106<br />

CCTV 106<br />

metal detectors – person<br />

& walk thru 106<br />

surveillance equipment 106<br />

thermal sensing cameras 104<br />

telecOmmunicatiOnS<br />

distortion analysers 26<br />

fibre optics testing & splicing 33<br />

frequency counters 12<br />

LAN/WAN analysis 31<br />

logic analysers & testers 10<br />

pulse generators 9<br />

RF & microwave 13<br />

RF amplifiers 13<br />

RF signal generators 13<br />

RF sweep generators 13<br />

WAN analysers 31<br />

training<br />

security & surveillance 106<br />

tranSpOrt<br />

automotive general testing 90<br />

data logging 70<br />

dc power supplies 7<br />

distance measurement 78<br />

endoscopes 79<br />

load measurement 85<br />

noise & sound analysis 120<br />

non-destructive testing (NDT) 88<br />

scales & balances 87<br />

thermal imaging cameras 104<br />

vibration & alignment analysis 88<br />

travel & leiSure<br />

metal detectors 106-107<br />

security equipment 106<br />

Water WaSteWater & plumbing<br />

data logging 70<br />

distance measurement & surveying 78<br />

electrochemistry 128<br />

endoscopes 79<br />

gas analysis & monitoring 123<br />

inclinometers 84<br />

liquid & gas flow measurement 110<br />

pipe locators 36<br />

water quality testing 128<br />

WOrkplace envirOnment<br />

air flow measurement 113-114<br />

air quality measurement 113-114<br />

data logging 70<br />

electrical insulating testing 41<br />

electrochemistry 128<br />

gas analysis & monitoring 123


ELEC<strong>TR</strong>ONICS & DATA


GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

2<br />

digital StOrage OScillOScOpeS<br />

Model Channels<br />

Bandwidth<br />

(MHz)<br />

Sampling Features Interfaces<br />

TEK,TDS2014<br />

TDS,TpS2014<br />

100 1GS/s<br />

Colour, automatic measurements.<br />

Colour, battery operated, automatic & power measurements<br />

TDS2CMA,<br />

GPIB, RS232<br />

YEW,DL1540L<br />

4<br />

150 200MS/s<br />

Tektronix TDS2014 100MHz 4 Channel Colour DSO<br />

TEK,TDS2014 AU<br />

Sampling rate 1GS/s. Sensitivity 2mV~5V/div. bandwidth limited to 20MHz<br />

when set to


Tektronix TDS3054B 500MHz 4 Channel DSO<br />

TEK,TDS3054b AU/NZ<br />

Sampling rate 5GS/s. Memory length 10 k. Sensitivity 1 mV - 10 v/div. Time<br />

base 1ns~10s/div. Trigger functions include video. Extensive automatic<br />

waveform measurements. Including FFT, TV trigger, advanced analysis<br />

(TDS3AAM), and limit testing (TDS3LIM). Colour LCD with digital phosphor<br />

function. VGA, GpIb (IEEE-488) & RS232 interfaces included (TDS3GV).<br />

In-built FDD. Comes with TDS3bATb for battery operation.<br />

Tektronix THS730A 200 MHz Battery DSO<br />

TEK,THS730A AU<br />

Dual channel battery portable digital storage oscilloscope with digital<br />

multimetre facilities. Max sampling rate 1GS/s. Suited to high voltage<br />

applications depending on probe selection. Max input 640V rms, max float<br />

600Vrms. Waveform processing including watts calculations. Video trigger.<br />

RS232 interface. Use TEK,WAVESTAR software for pC interface.<br />

Tektronix Wavestar Software for TDS DSO<br />

TEK,WAVESTAR AU<br />

Acquires, prints, and exports waveforms and screen images as graphics<br />

images or data values. Exports to common packages, eg. MS Word, Excel.<br />

Obtains data via RS232, GPIB and FDD.<br />

Yokogawa DL1540L 150MHz 4 Channel DSO<br />

YEW,DL1540L AU/MY<br />

In-built printer & FDD. Amplifier bandwidth 150MHz. Sampling rate 200MS/<br />

s. Sample memory of 2Mword for 2 channels & 1Mword for 4 channels.<br />

bMp, TIF HpGL, postscript & comma separated waveform formats. GO/<br />

NOGO testing of waveforms. External sample rate input - useful for rotating<br />

machinery work. Waveform computations including FFT. Averaging function<br />

to reduce the S/N ratio, accumulate function. GpIb interface.<br />

Fluke 196 100MHz 2 Channel Portable Scopemeter<br />

FLU,196 NZ<br />

Real-time sampling 1GS/s per input. Connect & view automatic triggering,<br />

a full range of manual trigger modes plus external triggering. 27,500 points<br />

per input record length using Scoperecord mode. Automatic capture and<br />

replay of 100 screens. Automatic waveform measurements 24. Cursors,<br />

zoom and real-time clock. 1kV independently floating isolated inputs.<br />

Includes a 5000 count true-rms multimeter and a Trendplot paperless<br />

recorder.<br />

Tektronix 2205GM 40MHz Dual Trace Oscilloscope<br />

TEK,2205GM AU<br />

Vertical sensitivity 5mV/div~5V/div. Timebase 0.1µs~0.5sec/div x10<br />

magnifier. TV line and field trigger.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

digital StOrage OScillOScOpeS<br />

Fluke 199C Scopemeter 200MHz Hand-held<br />

FLU,199C-SCOpEMETER AU<br />

FLU,199 NZ<br />

Colour digital oscilloscope, 200MHz bandwidth, 2 channel with DMM<br />

feature. Colour display 14.4cm with persistence feature. Real time sampling<br />

2.5GS/s. Input sensitivity 5mV/div~100V/div. Glitch capture 3ns using pulse<br />

width triggering. Timebase range in scope mode 5ns/div~2min/div. Trigger<br />

types auto, free run, single shot, edge, delay, video, video line, selectable<br />

pulse width & external. Automatic capture and replay of last 100 screens.<br />

Measures electrical power properties such as VA, VAR, etc. Inputs are<br />

isolated (1kV CAT II/600V CAT III). pC software. battery operation 4h.<br />

HP/Agilent MSO6104A 1GHz Digital Oscilloscope with Logic<br />

Hp,6104A AU<br />

Agilent 6104A 1 GHz 4 + 16 channel mixed signal oscilloscope (MSO).<br />

4Gsa/s. xGA Colour display updates 100,000 waveforms/sec with 256 levels<br />

intensity. 4 analogue channels and 16 logic channels. Deep memory. 8 digit<br />

frequency counter function. Triggering includes video, HDTV, I2C, SPI, LIN,<br />

CAN, and USb. FFT analysis included. LAN, USb, GpIb, & xGA interfaces<br />

standard.<br />

nOn-StOrage OScillOScOpeS<br />

Tektronix 300MHz Portable Oscilloscope 4 Channel<br />

TEK,2465 AU<br />

2mV~5V/div. Dual timebase with delayed sweep, 500ps~0.5s/div. 50Ω &<br />

1mΩ input impedance.<br />

GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 3


GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

4<br />

prObeS and acceSSOrieS<br />

Model Type Bandwidth Attenuation Voltage Max Current Max (A)<br />

FLU,80K-40<br />

DC~100MHz 1:1,000 40kV dc, 28kV ac<br />

MET,HT212-30KDC DC 1:100 30kV dc<br />

TEK,P6015 Voltage high<br />

75MHz 1:1,000 40kV<br />

COL,HV40b dc to 300Hz 1,000:1<br />

ACR,SI9000 Voltage isolation 15MHz 1:20, 1:200 700V<br />

bEL,CG-100A Current clamp-on AC DC dc~1kHz 660 rms 100<br />

TEK,p6302-CT5 Current clamp-on 20 MHz 50K<br />

TEK,P6158 Passive probe 30GHz 1:20<br />

TEK,5200 Differential probe dc to 25MHz 1300V<br />

See also Electrical Transducers<br />

Agilent 82357A GPIB/HPIB/IEEE488 to USB interface<br />

Hp,82357A AU<br />

Allows all GpIb/HpIb/IEEE488 equipment to controlled from any USb<br />

equipped pC (not MACs). Drivers for pC. Separate software may be<br />

required for equipment being controlled.<br />

Fluke 80K-40 High Voltage Probe<br />

FLU,80K-40 AU<br />

1~40kV dc or peak ac, 28kV ac rms. Input resistance 1GΩ, division ratio<br />

1,000:1. Note: input impedance of DVM must be 10MΩ or reading will be<br />

wrong.<br />

Acree SI9000 Differential Probe<br />

ACR,SI9000 AU<br />

Input probe for converting oscilloscopes, etc, to floating input for power<br />

measurements, etc. Input attenuation 1/20 & 1/200 with 2MΩ impedance to<br />

earth. bandwidth dc~15MHz. Max input 700Vac. Input range up to 700Vdc<br />

in 1/200 mode. battery operated.<br />

Bell CG-100 A Clip-on Current Gun<br />

bEL,CG-100A AU<br />

Current range dc, ac 10A~100A. DC~1kHz, accuracy 2%, 100% overrange<br />

capacity, clamp ¾“Ø, 30h battery operation, IV output for oscilloscope.<br />

National Instruments GPIB-USB Interface with Plotter Software<br />

NAT,GpIb-USb-HS AU<br />

High speed GpIb to USb interface. provides control of GpIb/HpIb/IEEE488<br />

devices from a USb equipped pC (requires Win 2000 or later operating<br />

system). Includes software to allow PC to emulate a GPIB plotter. Plotter<br />

software outputs plots as HpGL, HpGL/2, JpEG, TIFF, bMp & WMF. plotter<br />

software can emulate Hp 7440, Hp 7470, Hp 7475, Hp 7550 & Hp 7570<br />

pen-plotters.<br />

Tektronix P5200 Isolated Differential Probe<br />

TEK,P5200 NZ<br />

High voltage differential probe to provide a safe means of measuring circuits<br />

with floating potentials up to 1kV from earth to ground and up to 1,300V<br />

differential. Range settings are 1/50 & 1/500. bandwidth: dc to 25MHz<br />

accuracy is ±3%, input impedance is 8MΩ, 3.5 pF between inputs. Rise<br />

time is 14ns.<br />

Tektronix P6158 Passive RF Probe dc 3GHz 20X<br />

TEK,p6158 AU<br />

Attenuation dc~3GHz 20x. Input resistance 1kΩ.<br />

Tektronix P6015 40kV High Voltage Probe<br />

TEK,p6015 AU<br />

bandwidth 75MHz. Input rating: 40kV pulse, 20kVdc plus peak ac. Derating<br />

with frequency applies. Input impedance 100MΩ. Attenuation x 1000.<br />

USB to RS232 Converter<br />

USb,232CONVERTER AU<br />

Stackable expansion module that connects to a pC or server via the USb<br />

port. provides 1 high speed RS-232 serial port. System Requirements;<br />

pentium class, USb type A, Win 98, ME, 2000, xp, MAC 8.6 & later.


AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

multimeterS and electrOmeterS<br />

Model Type Application Scale (digit) Interface True RMS Max (V)<br />

FLU,177<br />

FLU,189<br />

HIO,3256-50 Digital HiTester multimeter General 6 No 1,000<br />

HIO,3805<br />

MET,Mx44<br />

Multi Function Digital<br />

Multimeter<br />

MET,Mx53<br />

General<br />

MET,Mx54<br />

Multimeter<br />

MET,Mx51Ex Intrinsically safe<br />

FLU,87<br />

FLU,87-2<br />

4½ 1,000<br />

Hp,3400A RMS voltmeter Audio/RF Analogue Analogue output 300<br />

FLU,8010A<br />

LEM,UNIGOR355 4¾<br />

General<br />

LEM,UNIGOR380 Multimeter<br />

6<br />

3½<br />

Yes<br />

IR interface Yes<br />

Hp,34401A<br />

RS232/HpIb<br />

6½<br />

Hp,3455A-NATA Precision HPIB Yes<br />

GOS,ME<strong>TR</strong>AHIT-29S<br />

powermeter - <strong>TR</strong>MS<br />

Multimeter<br />

1,000<br />

Precision ±310,000 count IR interface Yes CAT III 600<br />

SIM,SS2x Charge measurement Electrostatic Analogue 200 kV/m<br />

MMM,709 Electrostatic meter Static voltage 4 No 8,000<br />

> NEW<br />

Fluke 87-2 Digital Insulation Multimeter<br />

FLU,87-2 MY<br />

A combined digital insulation tester with a full-featured, true RMS digital<br />

multimeter in a single, compact, handheld unit, which provides maximum<br />

versatility for both troubleshooting and preventative maintenance.<br />

> NEW<br />

Fluke MultiMeter with Backlight<br />

FLU,177 AU<br />

General purpose multimeter. True RMS voltage and current measurements,<br />

digital display with analog bargraph and backlight, manual and automatic<br />

ranging, display Hold and Auto Hold, frequency and capacitance<br />

measurements. Overvoltage category EN61010-1 CAT III 1000V/CAT IV<br />

600V.<br />

GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 5


GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

6<br />

multimeterS and electrOmeterS<br />

> NEW<br />

Fluke Logging Multimeter<br />

FLU,189 AU<br />

Higher end multimeter. PC interface for data exchange, internal memory<br />

allows stand-alone logging of up to 1000 measurements. Extremely fast<br />

readings true RMS AC + DC measurements, 100kHz ac bandwidth for<br />

voltage and current, dual display with bargraph and two-level backlight, min/<br />

max/average with real time clock and 250µs Fast Min-Max, Temperature<br />

measurement -200ºC~1350ºC, dbV/dbm with selectable reference.<br />

Overvoltage category EN 61010-1 (IEC 1010-1) CAT III 1000V/CAT IV<br />

600V.<br />

> NEW<br />

Hioki 3805 Multi Function Handy Type Digital Multimeter<br />

HIO,3805 AU<br />

9999 count display full scale for voltage range. Optional RS232C package<br />

for transferring data to a PC, True rms rectified, easy harmonic distortion<br />

check function, simultaneous 2-point temperature measurement, maximum,<br />

minimum, average value display, 4~20mA measurement value convert to<br />

0-100 % display, for maintaining and serving industrial meter. Meets CAT III<br />

600V requirements and CAT II 1kV requirements.<br />

Gossen Metra Hit 29S Powermeter - <strong>TR</strong>MS Multimeter<br />

GOS,ME<strong>TR</strong>AHIT-29S AU<br />

High Precision Digital Multimeter<br />

Hioki 3256-50 Digital Multimeter CAT II 1kV & CAT III 600V<br />

HIO,3256-50 AU<br />

Hioki 3256-50 Digital HiTester Multimeter, CAT II 1000V and CATIII 600V<br />

AC/DC, Current 10A AC/DC.<br />

Metrix MX54 Digital Multimeter<br />

MET,Mx54 AU<br />

Measures ac/dc voltage and current, resistance, frequency, and capacitance.<br />

4½ digit display giving a sensitivity of 10µV & 10nA. Ranges: voltage<br />

500mV~1,000V (750V ac), current 500µA~10A, resistance 500Ω~50MΩ<br />

with a max resolution of 10mΩ, frequency; 0.6Hz ~500kHz; db measurement<br />

over impedance range 1~9,999Ω.<br />

Metrix MX55 <strong>TR</strong>MS Multimeter<br />

MET,Mx55 MY<br />

True rms digital multimeter measuring ac/dc voltage & current, resistance,<br />

frequency. 4.5 digit display.<br />

Metrix MX51EX Intrinsically Safe Digital Multimeter<br />

MET,Mx51Ex AU<br />

Resolution 5,000 count with 0.1% basic accuracy. Measures ac/dc voltage<br />

and current, and resistance. Voltage sensitivity 100µV. Max voltage 1kV dc,<br />

750Vac. Max current 10A. Intrinsic safety limits of 60V & 500mA.<br />

Metrix MX53 Hand Held Digital Multimeter<br />

MET,Mx53 AU<br />

Display 50,000 count with 34 segment bar graph. Vdc range 500mV~1kV.<br />

Vac range 500mV~750V. Current range 500µA~10A. Resistance<br />

range 500Ω~50MΩ. Capacitance range 50nF, 50mF. Frequency range<br />

0.6Hz~500kHz. Min & max value mode. Continuity and diode checking<br />

functions.<br />

HP 3400A ac True rms 10MHz Analogue Voltmeter<br />

Hp,3400A AU<br />

Analogue display 10Hz~10MHz, 1mV~300V FS. Recorder output.<br />

Fluke 87 Digital Multimeter<br />

FLU,87 NZ<br />

Handheld digital multimeter. Measures ac/dc voltage, current and resistance.<br />

peak hold feature.<br />

LEM Unigor 355 Hand-held Digital Multimeter/Signal Generator<br />

LEM,UNIGOR355 AU<br />

Measures dc, ac trms voltage & current, resistance, frequency, capacitance,<br />

temperature & time. Display 4¾ digit. Resolution 10µV, 10nA, 10mΩ, 1pF<br />

& 0.01Hz. Ranges voltage 300mV~1kV, current 300µA~10A, resistance<br />

300Ω~30MΩ, frequency 300Hz~100kHz, db -48~63, temperature ºC/ºF, pt<br />

100 -200~100ºC, pt 1000 100~850ºC. Features automatic socket shutters,<br />

IR interface, split second chronograph, automatic measurement value<br />

storage, etc.<br />

LEM Unigor 380 Digital Multimeter<br />

LEM,UNIGOR380 AU<br />

Precision 6 digit multimeter. Measures dc, ac trms voltage & current,<br />

resistance, frequency, capacitance, temperature & time. Resolution<br />

1µV, 1nA, 1mΩ, 1pF & 0.001Hz. Ranges voltage 300mV~1kV, current<br />

300µA~10A, resistance 300Ω~30MΩ, frequency 300Hz~300kHz, db -<br />

48~63, temperature ºC/ºF K -200~1,372ºC, J -210~1200ºC. Features<br />

automatic socket shutters, IR interface, split second chronograph, automatic<br />

measurement value storage, etc.<br />

HP 34401A Digital Multimeter<br />

Hp,34401A AU<br />

precision 6½ digit multimeter. 100nV sensitivity on dc 120mV range. Max dc<br />

input 1kV. Measures ac voltage, dc & ac current to 3A, 2 or 4 wire resistance<br />

to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths functions<br />

including limits test. 512 point storage. RS232 and HPIB interfaces.<br />

Keithley 2503 Static Detector Probe<br />

KEI,2503 AU<br />

Detects voltage due to charge on small surface areas. Used at a distance of<br />

6mm from a surface having a charged plane of at least 13mmØ.<br />

Simco SS2X Electrostatic Charge Meter (Analogue)<br />

SIM,SS2x AU<br />

Designed for detecting and measuring the voltage and field strength<br />

associated with static charges on objects and materials. Capable of<br />

measuring voltages from 0 ~200 KV and field strength from 0~4000MV/M<br />

3M 709 Electrostatic Meter<br />

MMM,709 NZ<br />

Digital electrostatic meter. Reads 20kV at 25mm distance, accuracy ±10%.<br />

2 volt recorder output.


Model Current Max (A) Voltage (Vdc) Dual Variable<br />

Hp,E3640A 3, 1.5 8, 20<br />

Yes<br />

LAb,622 2<br />

30<br />

RED-30V-30A 30 No<br />

bWD,246A 5 36 Yes<br />

<strong>TR</strong>I,pD35-20 20 35<br />

SOR,DCR10-120b 120 10<br />

SOR,DCR600-3b 3 600<br />

SOR,DCS60-50<br />

AUS,AD2K5<br />

INV,MpS48DC2400W<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

50<br />

<strong>TR</strong>I,pD35-10D 10 35<br />

xAN,xKW60-50 50 60<br />

BWD 246A Dual Power Supply<br />

bWD,246A AU<br />

Dual output 0~36V, 0~5A per section. Use in series, parallel or tracking<br />

modes.<br />

Trio PD35-20 DC Power Supply<br />

<strong>TR</strong>I,pD35-20 AU<br />

Output 0~35V, 0~20A. Constant current, constant voltage. Multiple parallel<br />

or series operation. Remote programming of voltage or current by external<br />

voltage or resistance.<br />

Ausmode AD2K5 48V 50A Rectifier<br />

AUS,AD2K5 AU<br />

DC rectifier (power supply), 50A @ 48V. Voltage not adjustable. Use to<br />

power telecoms and other battery supported equipment.<br />

Agilent E3640A Programmable DC Power Supply<br />

Hp,E3640A AU<br />

30W single-output programmable power supply with built-in GpIb and RS232<br />

connectivity and SCpI language compatibility. 0~8V/3A or 0~20V/1.5A.<br />

Over-voltage protection and remote sensing. Low noise and excellent<br />

regulation. Front and rear output terminals.<br />

Lab 622 Dual 0~30Vdc DC Power Supply<br />

LAb,622 NZ<br />

Adjustable current limit of 0~2A dc.<br />

Redfern 30V / 30A Power Supply<br />

RED,30V-30A NZ<br />

Adjustable current trip from 0~30V. Voltage and current meters.<br />

Sorensen DCR10-120B dc Power Supply<br />

SOR,DCR10-120b AU/MY<br />

0~10V, 0~120A.<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

60<br />

48<br />

dc pOWer SupplieS<br />

Sorensen DCR600-3B dc Power Supply<br />

SOR,DCR600-3b AU<br />

0~600V, 0~3A.<br />

Sorensen DCS60-50, 60V 50A dc Power Supply<br />

SOR,DCS60-50 AU<br />

0~60V, 0~50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph<br />

240V supply. On 1ph 50V @ 50A or 60V @ 42A. Remote programming.<br />

Trio Kenwood PD35-10D 35V 10A Power Supply<br />

<strong>TR</strong>I,pD35-10D AU<br />

Output 0~35V, 0~10A. Constant current, constant voltage. Multiple parallel<br />

or series operation. Remote programming of voltage or current by external<br />

voltage or resistance.<br />

Invensys Intergy Mini Power System 48V dc 2.4kW Supply<br />

INV,MpS48DC2400W AU<br />

Sub-rack Mini System 19” rack mount range. Ideal solution for low power<br />

telecommunications applications (premises Data Networks and Ip Routers,<br />

Local Loop Transmission Systems and Wireless) requiring compact, efficient<br />

and flexible dc power supplies. Includes an integral dc distribution panel<br />

and an SM30 Series Intergy Supervisory Module. All system settings are<br />

fully adjustable in software. Input: R1148: 220/240Vac, 50/60Hz (nominal).<br />

power factor: >0.98 @ 30~100% max system current. Efficiency: >89%.<br />

Output; voltage 48V, 45~60Vdc, current @ 48Vdc 50A (2400W). Dimensions:<br />

133H x 275W mm overall. Weight: 12kg typical configuration.<br />

Xantrek XKW60-50 60V 50A dc Power Supply<br />

xAN,xKW60-50 AU<br />

0~60V, 0~50A. Constant current and constant voltage. Analogue<br />

programming. Operation of multiple units in series or parallel.<br />

GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 7<br />

No<br />

Yes<br />

No<br />

Yes


GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

8<br />

functiOn generatOrS<br />

Model Special features Frequency Max (MHz) Frequency Min (µHz) Voltage Max Arbitary<br />

HP,3325B High stability & accuracy 21 MHz 1<br />

Hp,33120A 15 MHz 100<br />

Hp,33220A 20MHz<br />

Hp,33250A 80 MHz<br />

> NEW<br />

Tektronix 3022/25MHz Arbitrary Function Generator<br />

TEK,AFG3022 AU<br />

Dual channel function/arbitrary waveform generator. Frequency range<br />

1mHz ~25MHz sine, 12.5MHz square & pulse waveforms, 250 kHz triangle,<br />

ramp, noise & DC waveforms. Arbitrary waveform generation 12.5MHz.<br />

Gaussian noise to 25MHz. Output into 50Ω 10mV~10V p-p. AM, FM, FSK,<br />

and burst modulation. HpIb, USb, & LAN interfaces used with included<br />

software allows waveforms to be created on PC and imported into unit. Full<br />

screen display also allows display and editing of waveforms on unit itself.<br />

> NEW<br />

Tektronix 3102/100MHz Arbitrary Function Generator<br />

TEK,AFG3102 AU<br />

Dual channel function/arbitrary waveform generator. Frequency range<br />

1mHz~100MHz sine, 12.5MHz square and pulse waveforms, and 250kHz<br />

triangle, ramp, noise, and DC waveforms. 12.5MHz Arbitrary waveform<br />

generation. Gaussian noise to 25MHz. Output into 50ohms 10mV~10V p-p.<br />

AM, FM, FSK, and burst modulation. HpIb, USb, and LAN interfaces used<br />

with included software allows waveforms to be created on PC and imported<br />

into unit. Full screen display also allows display and editing of waveforms<br />

on unit itself.<br />

Agilent 33220A 20MHz Function/Arbitrary Generator<br />

Hp,33220A AU<br />

Function/arbitrary waveform generator. Frequency range 20MHz sine &<br />

square waveforms, 200kHz pulse, triangle, ramp, noise, and DC waveforms.<br />

Gaussian noise to 10MHz. Output into 50Ω 10mV~10V p-p. AM, FM, FSK,<br />

and burst modulation. Includes option 001 external timebase reference.<br />

With optional benchlink software waveforms can be captured and played<br />

back. HpIb, USb, & LAN interfaces.<br />

1<br />

10Vp-p Yes<br />

HP 33120A Function/Arbitrary Generator<br />

Hp,33120A AU/MY<br />

Frequency range 15MHz sine & square waveforms, and 100kHz triangle &<br />

ramp waveforms. Gaussian noise to 10MHz. Output into 50, 50mV~10V pp.<br />

AM, FM, FSK, and burst modulation. Optional benchlink software allows<br />

waveforms to be captured and played back. HpIb & RS232C interfaces.<br />

Some assets include option 001 phase lock and high stability TCxO timebase<br />

- input & output 10MHz with phase offset.<br />

HP 33250B Synthesized Function Generator<br />

Hp,3325b AU<br />

Sine frequency range 1µHz~21MHz, square wave/triangle/ramps to 11MHz.<br />

Sweep generator function. In-built modulation generator which includes<br />

arbitrary waveforms with arbitrary, sine, and square wave outputs. Output<br />

phase can varied with 0.1O resolution and multiple units can be locked<br />

together for variable phase output signals. Very high amplitude resolution<br />

and setting accuracy.<br />

HP/Agilent 33250A 80MHz Function/Arbitrary Waveform<br />

Generator<br />

Hp,33250A AU<br />

Frequency range 80MHz sine & square waveforms. 50MHz pulse waveforms<br />

with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz triangle &<br />

ramp waveforms. White noise to 50MHz. Output into 50Ω 10mVpp~10Vpp.<br />

AM, FM, FSK, and burst modulation. Intuilink software for programming<br />

arbitrary waveforms. HPIB & RS232C interfaces.


HP 8012B Pulse Generator<br />

Hp,8012b AU<br />

pulse generator 1Hz~50MHz. Variable transition times down to 5ns. Amplitude +10V with selectable source impedance. pulse width 10ns~1s. External<br />

trigger and gate.<br />

Stanford Research SR1720 LCR Bridge<br />

SR,SR720 AU<br />

Automatic LCR bridge with 0.05% accuracy. Ranges: inductance<br />

0.0001µH~99,999H; capacitance 0.0001pF~99,999µF; resistance<br />

0.0001Ω~2,000MΩ. Also measures Q & D. Test frequencies 100/120Hz,<br />

1/10/100kHz. Indicates value, deviation, % deviation, or bin number. DC<br />

bias internal 0~2V, external 0~40V. Complete with optional Kelvin leads.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

pulSe generatOrS<br />

lcr meterS<br />

Tegam 3550 45Hz-5MHz Programmable LCR Meter<br />

TEG,3550 AU<br />

programmable Impedance/LCR Meter. User selectable test frequency from<br />

42.0Hz~5.00MHz. 18mS measurement speed. 0.10% basic accuracy. Fully<br />

programmable with18 measurable parameters and absolute or percentage<br />

comparator. Binning function supports 10 output bins. Output to 3 highly<br />

visible LED displays. Standard RS232C & I/O interfaces<br />

Model Type Description Accuracy %<br />

DAN,DR60 Resistance box Decade resistance box<br />

GR,1433-20 Resistance Box Decade resistance box<br />

GR,1433b-NATA Resistance box 1~11.1MΩ Decade resistance box. 6 decades x 1Ω<br />

> NEW<br />

Genrad 1433-20 Decade Resistor<br />

GR,1433-20 MY<br />

Resistance range from 1mΩ~111MΩ. High accuracy 0.01% up to<br />

10MΩ steps. Low temperature coefficient, 5 ppm/°C. Good frequency<br />

characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero<br />

resistance (


GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

10<br />

lOgic/analySerS/teSterS<br />

> NEW<br />

Protek 3290 RF Analyser/Signal Meter 2.9GHz<br />

pRO,3290 AU<br />

RF signal analyser and level meter. Provides spectrum display up to 2.9<br />

GHz, audio output, level measurement, and frequency measurement. Inbuilt<br />

antenna. Frequency range 100 kHz to 2.9GHz with frequency steps from<br />

5 kHz. Modulation types narrow and wide band FM, AM, and SSb. Level<br />

measurement minimum frequency - narrow band FM 1 MHz, wide band FM,<br />

AM, SSb 10 MHz. bandwidth - narrow band FM 12.5 kHz, wide band FM<br />

180 kHz, AM & SSb 2.4 kHz. Input impedance 50 ohms.<br />

HP 1662A 68 Channel Logic Analyser<br />

Hp,1662A AU/MY<br />

Timing analysis 250MHz all channels, 500MHz half channels. Transitional:<br />

125MHz all channels, 250MHz half channels. Glitch: 125MHz half channels.<br />

State analysis to 100MHz on all channels. Memory 4k/channel, 8k/channel<br />

in half-channel modes. 4 clock channels available. HpIb & RS232C ports.<br />

In-built DOS format FDD used to load inverse assemblers and transfer<br />

measurement data to a computer. Compatible with most HP preprocessors<br />

and inverse assemblers.<br />

prOm prOgrammerS<br />

IceTech LV48 Programmer<br />

ICE,LV48 AU<br />

Eprom programmer for single device with laptop and preloaded software.<br />

programs devices up to 48 pins.<br />

Data IO Chipwriter Standard<br />

DAT,CHIpWRITER AU<br />

Eprom programmer for single device with laptop and preloaded software.<br />

programs devices up to 40 pins.<br />

Data IO Chipwriter Gang 8 Chip<br />

DAT,CHIp-GANG AU<br />

Eprom programmer for 8 devices. Eight copy sockets and one master socket.<br />

Can be used with a PC or in stand alone mode (two button operation).<br />

Programs devices up to 32 pin DIP.<br />

frequency reSpOnSe analySerS<br />

HP35660A 100kHz Dual Channel Spectrum Analyser<br />

Hp,35660A AU/MY<br />

Displays frequency response, power spectrum, linear spectrum, coherence,<br />

cross spectrum, power spectral density, and time. 401 line resolution. Signal<br />

sources: fixed sine, random noise, chirp. built-in disk drive. HpIb interface.<br />

bandwidth is 102.4kHz for single channel measurements and 51.2kHz for<br />

dual channel measurements.<br />

> NEW<br />

Agilent/HP 1652B 80 Channel Logic Analyser<br />

Hp,1652b AU<br />

80 channels, maximum conventional timing rate 100 MHz, transitional<br />

timing rate 100MHz & glitch timing rate 50MHz. Memory depth/channelnormal<br />

1Kb. Channel to channel delay 4ns. Minimum recognizable glitch<br />

width 5ns. Setup/hold time 10ns. 2 scope channels. bandwidth 100MHz.<br />

Simultaneous maximum sampling rate/Ch - 400 MSa/s. HpIb,RS232C.<br />

FDD.<br />

Agilent 16500C Logic Analyser<br />

Hp,16500C AU<br />

Mainframe with 16555D acquisition card and 16522A pattern generator<br />

module. 110MHz 68 channels. Memory depth 2M (4M in half channel<br />

timing mode). Minimum detectable glitch 3.5ns. Advanced trigger macros<br />

for capturing elusive problems.<br />

Hi-Lo All 11 Programmer<br />

ALL,11 AU<br />

programmer for byte wide EpROM, EEpROM and flash pROM with 24~32<br />

pins. Enables programming or copying of up to 8 devices at a time. Adaptors<br />

provided to convert standard dip arrangement to pLCC for programming/<br />

copying of single (one only) pLCC packages. Unit will handle devices up to<br />

8Mb. i.e. 27C010~27C080.<br />

Spectronics Ultra Violet PROM Eraser<br />

SpE,ERASER2 AU<br />

Holds up to 8 devices. 0~60min timer, 240V/50Hz operation.<br />

> NEW<br />

HP35670A 100kHz Spectrum Analyser<br />

Hp,35670A AU<br />

Quad channel 100 khz spectrum analyser. Up to 1600 line resolution.<br />

Displays frequency response, power spectrum, linear spectrum, coherence,<br />

cross spectrum, power spectral density, and time. Signal sources: Fixed &<br />

Swept sine, Arbitrary Waveform, Random noise, Chirp. built-in disk drive.<br />

HpIb plotter interface. bandwidth is 102.4, 51.2 and 25.6KHz for single,<br />

dual and quad channel measurements respectively.


Performance on-the-move<br />

Strength in the palm of your hand<br />

New U1250A series handheld DMMs place<br />

versatility at your fingertips!<br />

• 50,000 count resolution, dual displays<br />

• Unlimited data logging from DMM to PC<br />

• Programmable square wave generator<br />

• Temperature, Capacitance, Maths functions<br />

• 20MHz frequency counter<br />

New U1600A series handheld scopes bring high<br />

performance on the move!<br />

• Scope-DMM-Recorder - all-in-one<br />

• 4.5-inch LCD colour display<br />

• FFT, Zoom and Math functions<br />

• 200MSa/s sampling rate<br />

• 125kB/ch memory depth<br />

Australia 1300 726 550<br />

(Measurement Innovation - Australia wide)<br />

New Zealand 0800 738 378<br />

www.agilent.com/find/U1250A<br />

www.agilent.com/find/U1600A<br />

Say hello to the next generation of Agilent Technologies;<br />

the new handheld digital multimeters and oscilloscopes<br />

that are built to test and designed to save.<br />

Featuring built-in battery charging capability, exciting<br />

and innovative new features and over-mould casing for<br />

protection in the toughest conditions.<br />

If you need a test instrument that offers the ultimate<br />

portable test capabilities, Agilent’s range of handheld<br />

digital multimeters and oscilloscopes are the right choice.<br />

Redefining Feature-Rich Portability with<br />

the New Handheld Series<br />

View an online demo:<br />

www.agilent.com/find/U1250A_showcase<br />

www.agilent.com/find/U1600A_showcase


GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />

12<br />

frequency cOunterS<br />

Model Type Frequency (GHz)<br />

RAC,9906 Universal frequency counter dc~0.200<br />

SIC,WL260-pC230 Optical timing sensor<br />

PHI,PM6666<br />

Hp,5350A<br />

Universal frequency counter<br />

Hp,53181A dc~3<br />

HP,5352B Automatic microwave counter 10Hz~20GHz<br />

Hp,5385A Universal frequency counter, DC operation dc~1GHz<br />

ADV,<strong>TR</strong>5212 Universal frequency counter 10MHz~18GHz<br />

Racal 9906 Frequency Counter/Timer<br />

RAC,9906 AU<br />

Counter/timer 200MHz. Eight digit display. Measures frequency, period,<br />

totalise, time interval and ratio. Input impedance 1MΩ. Input sensitivity<br />

10mV.<br />

Sick WL260-P230 Reflex Photoelectric Switch<br />

SIC,WL260-p230 AU<br />

Light and sensor in the same unit. Detects reflection from reflector mounted<br />

on or behind the object to be detected. Range 0.01~5m. Output compatible<br />

with Racal 9906 counter. Mains operated. Supplied 50 x 50mm reflector.<br />

Does not work with normal mirror, white card etc, detects interruptions using<br />

supplied mirror.<br />

Philips PM6666 1.1GHz Universal Counter<br />

pHI,pM6666 AU<br />

Frequency, period, time interval, totalise, and ratio measurements. GPIB<br />

interface. High stability MTCxO timebase option fitted.<br />

dc~1<br />

HP 53181A 3GHz Frequency Counter<br />

Hp,53181A AU/MY<br />

Option 010 high stability timebase included. HPIB interface. PC based<br />

benchlink meter software available.<br />

HP 5350A 20GHz Frequency Counter<br />

Hp,5350A MY<br />

Automatic Microwave Counter. Input 1: 500MHz~20.0GHz 50Ω input<br />

impedance. Input 2 10Hz~525MHz at 50Ω. 10Hz~80MHz at 1 MΩ. HpIb<br />

interface standard. Option 006 input damage protection included.<br />

HP 5352B 40GHz Frequency Counter<br />

Hp,5352b AU<br />

Automatic microwave counter. Input 1 500MHz~40GHz. Input 2<br />

10Hz~525MHz. Sensitivity at 40GHz to 20dbm. TCxO timebase with aging<br />

rate 1 part in 10 million per month. HpIb interface. Input connector ApC-3.5<br />

(male) with collar; type N adaptor included.<br />

HP 5385A 1GHz Frequency Counter<br />

Hp,5385A AU<br />

Eleven digit display. Also measures period up to 0.1s. TCxO timebase.<br />

Operates from ac or 9~15Vdc. HpIb interface.


HP E4432B ESG-D3000A 3GHz RF Digital Signal Generator<br />

Hp,ESG-D3000A MY<br />

RF signal generator with digital modulation facilities. Frequency range<br />

250kHz~3GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation.<br />

Wideband AM modulation. DC to 10MHz. Internal modulation and pulse<br />

generator to 50kHz. Step sweep of frequency and power. Included option<br />

UN3 provides DECT, GSM, NADC, pDC, pHS, & TE<strong>TR</strong>A standards. External<br />

analogue I & Q modulation inputs. Option 1E5 high stability reference<br />

0.1ppm/yr included.<br />

HP E4433B ESG-D4000A 4GHz RF Digital Signal Generator<br />

Hp,ESG-D4000A AU<br />

Signal generator with digital modulation facilities. Frequency range<br />

250kHz~4GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation.<br />

Wideband AM modulation. DC to 10MHz. Internal modulation and pulse<br />

generator to 50kHz. Step sweep of frequency and power. Option 1E5 high<br />

stability reference 0.1ppm/yr included.<br />

HP 8648B 2GHz Signal Generator (Analogue)<br />

Hp,8648b AU/MY<br />

Frequency range 9kHz~2GMHz. Output range 13dbm~-136dbm, 1db<br />

accuracy over entire frequency range, resolution 0.001Hz. Full remote<br />

control via GpIb (IEEE488) interface.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

rf Signal generatOrS<br />

Model Type (All programmable) Frequency Output<br />

Hp,ESG-3000A AM/FM microwave signal generator 250kHz~3GHz<br />

Hp,ESG-D4000A AM/FM high stability microwave signal generator 250kHz~4GHz<br />

Hp,8648b High stability signal generator 9kHz~2GHz 13dbm~-136dbm<br />

Hp,8648C<br />

9kHz~3.2GHz<br />

AM/FM high stability signal generator<br />

Hp,8648D 9kHz~4GHz<br />

10dbm~-136dbm<br />

FLU,6060b AM/FM high stability signal generator 10kHz~1,050MHz -127dbm~13dbm<br />

HP 8350B Sweeper Mainframe<br />

Hp,8350b AU/MY<br />

Operates directly with Hp,8757A scalar network analyser and Hp,7475A<br />

plotter or Hp,2225A printer.<br />

HP 83525B 10MHz~8.4GHz Sweep Module<br />

Hp,83525b AU<br />

Sweep generator module for Hp,8350b. Frequency range 10MHz~8.4GHz.<br />

HP 83594A Module for 8350B 2 to 26.5GHz<br />

Hp,83594A AU<br />

broadband sweeper plug-in for Hp,8350b mainframe. Frequency range<br />

2~26.5GHz. Max levelled output 10mW up to 20GHz, 2.5mW up to<br />

26.5GHz.<br />

HP 8648C-1E5 3GHz Signal Generator<br />

Hp,8648C AU/MY<br />

Signal generator 9kHz~3.2GHz with AM/FM/phase modulation output range<br />

from +10~-136 dbm with ±1 accuracy up to 2.5GHz. 0.001Hz resolution.<br />

Complete with option 1E5 high stability timebase (


RF & MICROWAVE<br />

14<br />

Spectrum analySerS - high frequency<br />

Model Type Frequency Resolution (Hz)<br />

HP,8591E<br />

Hp,8594E<br />

Spectrum analyser<br />

Hp,8594E-G Spectrum analyser with tracking generator<br />

9MHz~1.8GHz<br />

9kHz~2.9GHz<br />

ADV,R3365A Spectrum analyser with tracking generator 100kHz~8GHz 10<br />

Hp,E4407b<br />

HP,8591 Spectrum analyser<br />

9kHz~1.8GHz 1kHz<br />

1kHz<br />

9kHz~26.5GHz 30<br />

HP,8593E 9kHz~22GHz 30<br />

HP,8563E Spectrum analyser, high resolution 9kHz~26.5GHz 1<br />

AIR,AIRMAG SpEC AN Spectrum analyser<br />

ANR,MS2711A Portable spectrum analyser<br />

ANR,MS2711D Spectrum analyser, colour, portable<br />

2.5~2.5GHz<br />

4.9~5.9GHz<br />

9kHz~3GHz<br />

ANR,MS2711D-6-29 Spectrum analyser with power meter 9kHz~6GHz<br />

ANR,S332b<br />

10<br />

Network analyser with spectrum analyser 9kHz~3GHz<br />

ANR,S332D 100<br />

ANR,S332D-29 Network analyser with spectrum analyser with colour screen 10<br />

RS,FSH3-TG Spectrum analyser with tracking generator and return loss bridge 100kHz~3GHz<br />

RS,FSH3-TG-V Spectrum analyser with tracking generator and vector measurements 100kHz~3GHz<br />

RS,FSH6-TG<br />

100kHz~6GHz<br />

Portable spectrum analyser<br />

ADV,U3771 9kHz~31.8GHz 100<br />

www.rohde-schwarz.com.au<br />

sales@rohde-schwarz.com<br />

Gear up for your next adventure<br />

The R&S®FSH - for on-site RF measurements<br />

Where is your next adventure in RF measurements taking you? To install a base station on the African savanna?<br />

To perform distance-to-fault measurements on the International Space Station? Then you need a flexible and robust<br />

do-it-all solution - the R&S®FSH Handheld Spectrum Analyser. It’s an entire test lab that fits in one hand: spectrum<br />

analyser, vector network analyser, high-precision power meter, test receiver, EMI/EMCE analyser and much more.<br />

It also features a wide selection of accessories.<br />

10kHz<br />

100<br />

1kHz


Rohde & Schwarz FSH3 Spectrum Analyser/Tracking Generator<br />

RS,FSH3-TG AU/NZ<br />

Handheld portable battery operated spectrum analyzer 100kHz~3GHz.<br />

Resolution bandwidth 1kHz~1MHz. Noise level to 3GHz -112dbm typical,<br />

5-6GHz -102dbm typical. Colour liquid crystal display. Suitable for RF<br />

surveying applications. Includes tracking generator, VSWR bridge and<br />

distance to fault (DTF) options making it suitable for antenna and cable<br />

testing. Four hours of continuous operation on battery power. Cable for<br />

data transfer to PC.<br />

Rohde & Schwarz FSH6 Spectrum Analyser/Tracking Generator<br />

RS,FSH6-TG AU/NZ<br />

Specification as above but capacity is 6GHz.<br />

> NEW<br />

Airmagnet Spectrum Analyser<br />

AIR,AIRMAG SpEC AN AU<br />

Laptop base spectrum analyser. Specifically identify sources of interference<br />

in all Wi-Fi bands 2.4~2.5GHz and 4.9~5.9GHz, and track them to their<br />

physical source. Automatic and real time identification of bluetooth, cordless<br />

phones, microwaves, analog video cameras, RF jammers and more.<br />

Immediately “see” and name each device.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

Spectrum analySerS - high frequency<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

> NEW Rohde & Schwarz FSH3 Spectrum Analyser/<br />

Tracking Generator /Vector Measurements<br />

RS,FSH3-TG-V AU<br />

Handheld portable battery operated spectrum analyser 100kHz~3GHz.<br />

Resolution bandwidth 1kHz~1MHz. Less than -105dbm noise level<br />

(-114dbm typical). Colour liquid crystal display. Suitable for RF surveying<br />

applications. Includes Vector Transmission and Reflection Measurements<br />

option, tracking generator, VSWR bridge and distance to fault (DTF) options<br />

making it suitable for antenna and cable testing. 4h of continuous operation<br />

on battery power. Comes with cable for data transfer to PC.<br />

HP 8591E 1.8GHz Spectrum Analyser<br />

Hp,8591E AU<br />

Range 9kHz~1.8GHz. Resolution 1kHz~3MHz. Card reader allows data<br />

storage and also downloading of a range of measurement options (not<br />

included). Most assets include option 010 tracking generator and option<br />

021 HpIb interface. One analyser includes; option 130 gives 30~300Hz<br />

resolution, option 041 HpIb interface and quasi peak detector and option<br />

103 AM/FM demodulation.<br />

> NEW<br />

Advantest 31.8GHz Portable Spectrum Analyser<br />

ADV,U3771 AU<br />

portable 9k to 31.8GHz spectrum analyser. 3 way power battery, 240V &<br />

DC. RbW 100Hz-3MHz, sensitivity -117 dbm@34 GHz (typ). Includes a<br />

wide variety of data analysis functions & zoom function. With signals applied<br />

to both Input 1 and Input 2, two signals such as an IF signal and a carrier<br />

can be measured. 5 min warm-up, Support for USb for printer and memory<br />

Storage Image formats: pNG, bMp, configuration file bIN, xML. Colour<br />

LCD. OpT.20-High-stability frequency reference crystal.<br />

Advantest R3365A 8GHz Spectrum Analyser with Tracking<br />

Generator<br />

ADV,R3365A AU<br />

Frequency range 100kHz~8GHz. Sensitivity -145dbm. Resolution<br />

10Hz. Adjacent channel leakage power measurement and digital radio<br />

measurement functions. Gated sweep function for TDMA and video signal<br />

analysis. In-built tracking generator 100kHz~3.6GHz. GpIb & RS232<br />

interfaces. Memory card reader.<br />

HP/Agilent E4407B 26.5GHz Spectrum Analyser<br />

Hp,E4407b AU<br />

Frequency range 9kHz~26.5GHz. Resolution bandwidth down to 30Hz.<br />

Noise level -105~-136dbm according to frequency. Centre frequency display<br />

with a resolution of up to 10Hz. Stores up to 200 traces in internal memory<br />

and 200 traces on disk. Some assets include GpIb/parallel interface with<br />

benchlink software (option A4H) and narrow resolution black/white (option<br />

1DR).<br />

RF & MICROWAVE<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 15


Field tested.<br />

Field trusted.<br />

Master every challenge the fi eld throws your way<br />

Field-proven, built to last, and easy to use, the Master family from Anritsu is<br />

the most trusted family of handheld measurement tools for RF and Microwave<br />

fi eld testing. So whatever you need to measure, and wherever you need to test,<br />

you can rely on one of the end-to-end, application-specifi c solutions in our<br />

Master family.<br />

Call 1800 689 685 (Australia only) or visit our US web site www.us.anritsu.com


HP 8593E 22GHz Spectrum Analyser<br />

Hp,8593E AU/MY<br />

Frequency range 9kHz~22GHz. Max resolution 30Hz. Noise level -102~-<br />

127dBm according to frequency. Centre frequency display with a resolution<br />

of up to 10Hz. Some assets include GpIb/parallel and narrow resolution<br />

black/white options (041 & 130).<br />

HP 8582A 22GHz Spectrum Analyser<br />

Hp,8562A MY<br />

RF Spectrum Analyser, 9kHz to 22GHz. resolution 100Hz to 2MHz. HpIb<br />

plotter interface.<br />

HP 8563E Spectrum Analyser<br />

Hp,8563E AU/MY<br />

Range 9kHz~26.5GHz. Resolution 1Hz~2MHz. Sensitivity up to -139dbm.<br />

HPIB plotter and printer interface.<br />

HP 8594E Spectrum Analyser<br />

Hp,8594E MY<br />

Range 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or<br />

less than 122dbm & 5MHz~2.9GHz equal to or less than 127dbm for 30Hz<br />

RBW.<br />

HP 8594E-G Spectrum Analyser with Tracking Generator<br />

Hp,8594E-G MY<br />

Range 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or less<br />

than 122dbm & 5MHz~2.9GHz equal to or less than 127dbm for 30Hz RbW.<br />

With tracking generator option installed.<br />

Anritsu MS2711A Portable Spectrum Analyser<br />

ANR,MS2711A MY<br />

portable spectrum analyser, 9kHz~3GHz. Light weight battery powered<br />

spectrum analyser with LCD. Resolution bandwidth down to 10kHz.<br />

Suitable for cellular telephone walk or drive tests to determine coverage and<br />

base station positioning. Can also be used for VHF/UHF signal surveying.<br />

N type connector.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

Spectrum analySerS - high frequency<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Anritsu MS2711D 6GHz Spectrum Analyser with Power Meter<br />

ANR,MS2711D-6-29 AU<br />

portable spectrum analyser, 9kHz~6GHz with power meter. Light weight<br />

battery powered spectrum analyser with LCD. Resolution bandwidth from<br />

100Hz~1MHz. Has feature which can identify the type of interfering signal.<br />

Can be used in applications such as cellular telephone walk or drive tests to<br />

determine coverage and base station positioning and also VHF/UHF signal<br />

surveying. Has N type connector.<br />

Anritsu MS2711D Colour Portable Spectrum Analyser<br />

ANR,MS2711D AU<br />

Colour portable spectrum analyser, 9kHz~3GHz. Light weight battery<br />

powered spectrum analyser with colour LCD. Resolution bandwidth from<br />

100Hz~1MHz. Has feature which can identify the type of interfering signal.<br />

Can be used in applications such as cellular telephone walk or drive tests to<br />

determine coverage and base station positioning and also VHF/UHF signal<br />

surveying. N type connector.<br />

> NEW<br />

Anritsu Frequency Converter Module FCN4760<br />

ANR,FCN4760 AU/MY<br />

block down converter for the 4.7GHz~6.0GHz frequency range designed to<br />

work with an ANR,MS2711D (with Option 6). Adds frequency range 4.7GHz<br />

~6.0GHz to the ANR,MS2711D.<br />

RF & MICROWAVE<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 17


RF & MICROWAVE<br />

18<br />

netWOrk analySerS/antenna & cable teSt<br />

Model Type Frequency<br />

ANR,S331b Antenna & cable test set 25MHz~3.3GHz<br />

ANR,S331C<br />

ANR,S331D<br />

Antenna & cable test set 25MHz~4GHz<br />

ANR,S332b Antenna & cable test set plus spectrum analyser 25MHz~3.3GHz<br />

ANR,S332D Antenna & cable test set plus spectrum analyser 25MHz~4GHz<br />

ANR,S820A Antenna & cable test set 3GHz~20GHz<br />

ANR,S820A Microwave antenna and cable test set 25Mhz~20GHz<br />

ANR,C752-05 Antenna & cable test set (75ohm) plus power meter 5MHz~1.2GHz<br />

Hp,8752A Vector network analyser transmission reflection test set 300kHz~3GHz<br />

Anritsu S331D Colour Sitemaster Antenna<br />

ANR,S331D AU/MY<br />

Antenna and cable test set. battery operated with colour display. Frequency<br />

range 25~4000MHz. Measures return loss, SWR, cable loss, and distance<br />

to fault. Integral synthesized signal generator. Return loss range 0~60db.<br />

SWR range 1~65. Distance to fault range 1,197m. Insertion loss range -<br />

120.00~+100db. Cable loss range (one port) 0~30db. Type n(f) port. RS232<br />

interface for printer or pC. Analysis software discs included containing<br />

distance to fault and Smith chart tools. Complete with Instacal calibration<br />

standard, AC/DC adaptor and 12Vdc car cigarette lighter adaptor.<br />

Anritsu S332B Sitemaster including 3GHz Spectrum Analyser<br />

ANR,S332b AU<br />

Antenna and cable test set with spectrum analyser. Frequency range<br />

25~3300MHz for cable and antenna test. 9kHz~3GHz for spectrum analysis.<br />

Measures return loss, SWR, cable loss, and distance to fault. Integral<br />

synthesized signal generator. Return loss range 0.00 to 54.00 db. SWR<br />

range 1.00 to 65.00. Distance to fault rang e 1000 m. Insertion loss range<br />

-120.00 to +100 db. Cable loss range (one port) 0.00 to 20.00 db. Type<br />

n(f) port. RS232 interface for printer or PC. Spectrum analyser resolution<br />

bandwidth down to 10 KHz. Analysis software discs included containing<br />

distance to fault and Smith chart tools. Complete with standard load and<br />

short, AC/DC adaptor and 12 V DC car cigarette lighter adaptor.<br />

Anritsu S332D Colour Sitemaster incl 3GHz Spectrum Analyser<br />

ANR,S332D AU/NZ<br />

Antenna and cable test set with spectrum analyser. battery operated with<br />

colour display. Standard signal table allows automated setup. Frequency<br />

range 25~4GHz for cable and antenna test. 9kHz~3GHz for spectrum<br />

analysis. Measures return loss, SWR, cable loss, and distance to fault.<br />

Integral synthesized signal generator. Return loss range 0~60db. SWR<br />

range 1~65. Distance to fault range 1,197m. Cable loss range 0~30db.<br />

Spectrum analyser resolution bandwidth 100Hz~1MHz. Interfering signal<br />

feature allows identification of type of interference. Type N(f) port. RS232<br />

interface for printer or pC. Analysis software discs included containing<br />

distance to fault and Smith chart tools. Complete with calibration components,<br />

ac/dcadaptor and 12Vdc car cigarette lighter adaptor.<br />

Return<br />

Loss<br />

HP,8753D<br />

30kHz~6GHz<br />

Vector network analyser S parameter test set<br />

HP,8753ES 30kHz~3GHz Yes Yes<br />

HP,8757C<br />

60GHz<br />

Scalar network analyser<br />

HP,8757D 10Mhz Yes Yes<br />

SWR RS232 dc Supply<br />

Yes Yes Yes Yes<br />

Anritsu S820A Microwave Sitemaster 3~20GHz<br />

ANR,S820A AU<br />

Microwave antenna and cable test set. portable (1.14kg) single post<br />

analyser, providing return loss (SWR) insertion loss and distance to fault<br />

measurements in the frequency range of 3.3GHz~20GHz. RS232 interface.<br />

Smith chart and software management tools, ac/dc and automotive adaptor.<br />

A comprehensive range of precision waveguide components and adaptors<br />

are available.<br />

Anritsu S820D Microwave Sitemaster 25MHz~20GHz<br />

ANR,S820D AU<br />

Microwave antenna and cable test set. Portable single post analyser,<br />

providing return loss (SWR) insertion loss and distance to fault measurements<br />

in the frequency range of 25MHz~20GHz. Unit comes standard with<br />

RS232 interface, Smith chart and software management tools, AC/DC<br />

and automotive adaptor. A comprehensive range of precision waveguide<br />

components and adaptors are available.<br />

Anritsu Sitemaster Waveguide Components<br />

ANR,WAVE<strong>GUIDE</strong>-ADAp AU<br />

Calibration components and wave guide to co-ax adaptors for Anritsu S820A<br />

Sitemaster antenna. Set includes 1/8 and 3/8 shorts, termination, and<br />

waveguide to co-ax adaptor.<br />

HP 8753D 6GHz Vector Network Analyser<br />

Hp,8753D AU<br />

Vector network analyser with integral S-parameter test set. Frequency range<br />

30kHz~6GHz with included option 006. In-built 1Hz resolution synthesized<br />

signal source. Calibration kit included.<br />

HP 8753ES 3GHz Vector Network Analyser<br />

Hp,8753ES AU/MY<br />

3GHz Vector Network Analyser allows complete characterization of RF<br />

components. Includes an integrated synthesized source, test set and tuned<br />

receiver. The built-in S-parameter test set provides a full range of magnitude<br />

and phase measurements in both the forward and reverse directions.


HP 8757A Scalar Network Analyser<br />

Hp,8757A AU<br />

Scalar network analyser (Scalar denotes gain measurement only - no phase).<br />

76db dynamic range. Frequency range to 60GHz depending on detector<br />

used. 3 x Hp11664A’s included. Analyser will act as system controller with<br />

HP8350B sweeper. Output to HPIB plotter or HP2225 printer.<br />

HP 8757C Scalar Network Analyser<br />

Hp,8757C AU<br />

Scalar network analyser 10 MHz~40 GHz. 76db (+16 to -60dbm) dynamic<br />

range. Three detector inputs. Two display channels. Color display.<br />

Complete with 3 x Hp,11664A detectors.<br />

HP 8757D Scalar Network Analyser<br />

HP,8757D<br />

Measures insertion loss, gain, return loss, SWR, and power from<br />

10MHz~110GHz.<br />

HP 11679A Detector Extension Cable<br />

Hp,11679A MY<br />

Extension cable for use with Hp,11664A detectors and Hp,8757 network<br />

analysers. Length 7m. Extends the power and detected signal cable<br />

length.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

netWOrk analySerS/antenna & cable teSt<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

HP 85032B Calibration Kit<br />

Hp,85032b AU<br />

Calibration kit for network analysers. Simplified version without adaptors.<br />

> NEW<br />

Emerson Process Management 375 Field Communicator<br />

EME,375 MY<br />

Will configure, test, and diagnose your HART® and Foundation Fieldbus<br />

devices. Able to communicate with any device, by any manufacturer.<br />

Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS pC<br />

Suite Software.<br />

Model Type Frequency<br />

ANR,WIFI-ANTENNA WIFI antenna 2.4GHZ~5.8GHz<br />

ANR,ANTENNA Dipole antenna 25MHz~1.7 GHz<br />

ADV,<strong>TR</strong>1720 Loop vertical antenna system 100kHz~30 MHz<br />

AH,SAS-200/574<br />

18GHz~40 GHz<br />

Double ridge guide horn antenna<br />

AH,SAS-200/571 700MHz~18 GHz<br />

RS,HL013 Log periodic antenna 80MHz~1300 MHz<br />

AN,SAS-200/550 Monopole rod antenna 100kHz~60 MHz<br />

HOL,HI-3002 Isotropic RF radiation monitor 500kHz~6 GHz<br />

NAR,8616 Radio frequency radiator monitor 300MHz~26 GHz<br />

SE,MONITOR 4 Alpha, beta, Gamma and x-Ray radiation monitor<br />

SE,MCIK Gamma x-Ray radiation monitor<br />

field Strength meterS & antennaS<br />

HOL,HI-3004 Isotropic RF low level field strength meter 0.5MHz~6 GHz<br />

WG,ESM-20 personal RF field monitor 1MHz~18 GHz<br />

NAR,8217 Field strength meter for microwave ovens 2.4GHz<br />

ROb,Tx90 Microwave oven leakage detector 2.4GHz<br />

PRO,3201 RF signal analyser & meter 100kHz~2.06GHz<br />

AH,ANTENNA<br />

See also TV Test Equipment<br />

Log periodic antenna 300MHz~12GHz<br />

Advantest <strong>TR</strong>1720 100kHz ~30MHz Antenna<br />

ADV,<strong>TR</strong>1720 AU<br />

Loop and vertical antenna system. Frequency range 100kHz~30MHz.<br />

Suitable for use with ADV,R4131D for field strength and EMI measurements.<br />

Antenna tuner included which can be used as an input/output filter to reject<br />

noise below the measuring frequency.<br />

AH Systems SAS-200/571 Antenna<br />

AH,SAS-200/571 AU<br />

AH,SAS-571 MY<br />

Double ridge guide horn antenna. Frequency range 700MHz~18GHz.<br />

Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type<br />

N(f) connector.<br />

AH Systems SAS-200/574 18~40GHz Antenna<br />

AH,SAS-200/574 AU<br />

Double ridge guide horn antenna 18~40GHz. Gain in excess of 15db. Type<br />

K(f) connector compatible with 3.5mm connectors including SMA. Complete<br />

with tripod.<br />

AH SAS-200/550-2B 100Hz~60Mhz Rod Antenna<br />

AH,SAS-200/550 AU<br />

Monopole rod antenna. Frequency range 100Hz~60MHz. Active unit with<br />

battery power. Rod height 220mm~1.09m. Ground plane 450 x 450mm.<br />

Antenna factor 0~24.<br />

RF & MICROWAVE<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 19


RF & MICROWAVE<br />

20<br />

field Strength meterS & antennaS<br />

AH Systems 300MHz ~12GHz Antenna System<br />

AH,ANTENNA AU<br />

Log periodic antenna system. Comprises two antennas: A: 300MHz~1.8GHz,<br />

power handling 1kW, antenna factor 15~32db, b: 1~12GHz, power handling<br />

10W, antenna factor 25~44db. Complete with tripod.<br />

Anritsu Dipole Antenna Kit<br />

ANR,ANTENNA AU<br />

Comprises types Mp534A and Mp651A antenna covering 25~520 &<br />

470~1,700MHz. Complete with tripod type Mb9A and coaxial cable.<br />

Anritsu 2.4/5.8GHz WIFI 802.11A/B/G Antenna<br />

ANR,WIFI-ANTENNA<br />

High precision antenna set for wireless network test applications (802.11A/b/<br />

G, 11Mbps &54 Mbps). Includes 2.4GHz and 5.8GHz antennas with reverse<br />

SMA connectors. Also includes precision reverse SMA to N type adapter to<br />

fit standard test equipment.<br />

Rohde & Schwarz HL013 80MHz~1.3GHz Log-Periodic Antenna<br />

RS,HL013 AU<br />

Complete with tripod.<br />

Holaday HI-3002 Field Strength Meter<br />

HOL,HI-3002 AU<br />

Isotropic RF radiation monitor. E-field & H-field probes spanning<br />

500kHz~6GHz (E-field) & 5~300MHz (H-field). Operates from batteries.<br />

Narda 8616 Radiation Hazard Monitor<br />

NAR,8616 AU<br />

Radio frequency radiation monitor complete with probes. Battery operated<br />

with analogue meter and recorder output (3Vdc full scale). Probe type<br />

8623b has a calibrated frequency range of 300MHz~26GHz over a range<br />

of 0.05~100mW/cm2 . (Frequency range up to 8GHz is calibrated to NATA<br />

standard, above 8GHz calibration is to manufacturer’s specifications).<br />

probe type 8633 has a frequency range of 10~300MHz over a range of<br />

0.05~100mW/cm2 .<br />

SE International Monitor 4 Nuclear/X-Ray Monitor<br />

SE,MONITOR 4 AU/MY<br />

Alpha, beta, Gamma & x-ray radiation monitor. Meter, LED & audible<br />

indication. Range; 0~0.5, 5, 50mR/hr, 0~500, 5,000, 50,000CpM, 0~5, 50,<br />

500µSv. Energy sensitivity Alpha 2.5MeV, beta 50KeV, Gamma & x-ray<br />

10KeV. Battery operated.<br />

SE International Monitor MC1K Radiation Survey Meter<br />

SE,MCIK AU<br />

Gamma & x-ray radiation monitor. Meter, LED, and audible indication.<br />

Ranges 0.1~1,000mR/h & 0.01~10mSv/h full scale. battery operated.<br />

mOdulatiOn meterS<br />

Holaday HI-3004 Field Strength Meter<br />

HOL,HI-3004 AU<br />

Isotropic broadband field strength meter designed primarily to measure<br />

low level fields for EMI/EMC studies. Meter scale calibrated in v/m, with<br />

pointer deflection proportional to v2/m2 . Supplied with HSE high sensitivity<br />

E-field probe & STE E-Field probe. HSE probe has 4 ranges, 1v/m ~30v/<br />

mFS, 0.5~1,500Mhz. STE probe has 4 ranges 100v/m~3,000v/mFS,<br />

0.5Mhz~6Ghz. Recorder output (0~1Vdc).<br />

WG ESM-20 Radiation Meter<br />

WG,ESM-20 AU<br />

personal monitor and leakage detector for high frequency electromagnetic<br />

fields. Simultaneous E and H field measurements with audible and visual<br />

alarms. Frequency range H field 1 MHz to 1 GHz; E field 1 MHz to 40<br />

GHz. Operation as personal monitor with compensation for human body<br />

absorption, or with isotropic detection for RF leakage sensing and simple<br />

four-level measurement using LED indicators. battery powered - battery life<br />

over 200 hours.<br />

Narda 8217 Microwave Oven Survey Meter<br />

NAR,8217 AU<br />

Microwave oven survey meter complete with beaker and thermometer for<br />

oven power measurement. Calibration frequency 2.45GHz. Measurement<br />

range 0.5~10mW/cm2 . Battery operated.<br />

Robin Electronics TX90 Microwave Leakage Detector<br />

ROb,Tx90 AU<br />

Microwave leakage detector. Eight dipole analogue meter reading. Ranges<br />

1~10mW/sqcm & 0·1~1mW/sqcm. Display analogue moving coil. power<br />

density accuracy ±1dB. Probe area 2cm2 . Supplied with a manufacturers<br />

certificate of calibration traceable to National Standards. Powered by 9V<br />

alkaline battery.<br />

Protek 3201 RF Analyser/Signal Meter<br />

pRO,3201 AU<br />

RF signal analyser and level meter. Provides spectrum display up to<br />

2.06GHz, audio output, level measurement, and frequency measurement.<br />

Inbuilt antenna. Frequency range 100kHz~2.06GHz with frequency steps<br />

from 5kHz. Modulation types narrow and wide band FM, AM, and SSb.<br />

Level measurement min frequency - narrow band FM 1MHz, wide band FM,<br />

AM, SSb 10MHz. bandwidth - narrow band FM 12.5kHz, wide band FM<br />

180kHz, AM & SSb 2.4kHz. Frequency measurement 9MHz~2.06GHz.<br />

Input impedance 50Ω.<br />

Protek 3290 RF Analyser/Signal Meter 2.9GHz<br />

pRO,3290 AU<br />

RRF signal analyser and level meter. Provides spectrum display up to<br />

2.9GHz, audio output, level measurement, and frequency measurement.<br />

Inbuilt antenna. Frequency range 100kHz~2.9GHz with frequency steps<br />

from 5kHz. Modulation types narrow and wide band FM, AM, and SSb.<br />

Level measurement minimum frequency - narrow band FM 1MHz, wide band<br />

FM, AM, SSb 10MHz. bandwidth - narrow band FM 12.5kHz, wide band FM<br />

180 kHz, AM & SSb 2.4 kHz. Input impedance 50Ω.<br />

Marconi TF2304 Auto AM/FM Modulation Meter<br />

MAR,TF2304 AU<br />

Automatic operation. Frequency 9~12.5MHz & 18~1,000MHz, FM deviation 8 ranges, 1.5~150kHz FS AM depth 3 ranges, 10~30~100%.


Laplace RF Absorbing Clamp<br />

LAp,RF-CLAMp AU<br />

For measurement of emissions from power and other lines to CISPR and<br />

VDE standards. Frequency range 30 MHz~1GHz. Output 50Ω.<br />

Laplace SA1000 EMC Test System<br />

LAp,SA1000 AU<br />

Comprises pC controlled spectrum analyser 10kHz~1.1GHz, SA1020 preamplifier,<br />

RF200 broadband antenna 30MHz~1Hz, TTI LISN1600 LISN,<br />

and RF100 E-field & H-field probes. Supplied with notebook pC and EMC<br />

software.<br />

> NEW<br />

Schaffner Modula-6100 Immunity Test System<br />

SFN,MODULA 6100 AU<br />

Multifunction generator to simulate electro-magnetic field interference effects<br />

for immunity testing in conformity with international, national and in house<br />

standards including the new IEC/EN standards. Generates Interference<br />

pulses such as burst and surge and power quality simulations.<br />

Marconi 2945 Communications Test Set<br />

MAR,2945 AU<br />

Output frequency range 400kHz~1.05GHz. Input frequency range to<br />

modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking<br />

generator with offset tracking inbuilt. power measurement to 150W. Full<br />

duplex operation. AMpS cellular option included. Spectrum analyser with<br />

1kHz resolution. AC mains, external 11~32V and internal battery operation.<br />

RS232C remote control interface.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

emc teSt equipment<br />

Schaffner 438 30kV Static Discharge Generator<br />

SFN,438 AU<br />

Generates an electrostatic charge in a range from 2~30kV. This instrument<br />

is in a ‘gun’ form. Removable discharge network which can be interchanged<br />

with other (optional) impedance networks. performs test to IEC1000-4-2<br />

standards.<br />

> NEW<br />

Schaffner Automated Step Transformer<br />

SFN,INA-6502 AU<br />

Integrated function unit to Modula system. power line dips to 0%, 40%, 70%<br />

and 80%. Complies with EN/IEC 61000-4-11. Includes EUT power control<br />

switch.<br />

Schaffner BestPlus B-1<br />

SFN,bEST+ AU<br />

EMC, ESD, PQT, Burst and Surge Immunity generator simulators. Includes<br />

ESD generator/gun.<br />

Schaffner NSG-420 RF Current Immunity Tester<br />

SFN,NSG-420 AU<br />

provides pre-compliance testing to IEC 801-3 and IEC 801-6. Clamp coupled<br />

to power, data, and signal cables of a device under test. Injects noise signal<br />

from 100kHz~100MHz with a level response from 1MHz~10MHz. AM &<br />

FM modulation of source from a 1kHz oscillator source or an external input.<br />

Indication of signal current from source or existing signal. Also dc recorder<br />

output of this signal. Cable size up to 10 x 22mm. Operates for 1h on 4AA<br />

alkaline batteries.<br />

cOmmunicatiOnS teSt SetS<br />

Marconi 2945A Communications Test Set<br />

MAR,2945A AU<br />

Output frequency range 400kHz~1.05GHZ. Input frequency range to<br />

modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking<br />

generator with offset tracking in-built. power measurement to 150W. Full<br />

duplex operation. Spectrum analyser with 1kHz resolution. AC mains,<br />

external 11~32V dc on some assets, and external battery operation. RS232C<br />

remote control interface.<br />

HP 8920A Communications Test Set<br />

Hp,8920A AU<br />

RF Communications Analyser test set. Frequency range of 250KHz~1GHz.<br />

Includes an AM/FM signal generator, AM/FM modulation analyser, duplex<br />

offset generator, SSb demodulator, RF power meter, frequency counter, ac/<br />

dc voltmeter, SINAD meter, Distortion meter, oscilloscope and two variable<br />

audio sources. Includes Spectrum analyser with tracking generator. Antenna<br />

& microphone are included.<br />

RF & MICROWAVE<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 21


RF & MICROWAVE<br />

22<br />

pOWer meterS & SenSOrS - rf<br />

Model Type Frequency Power<br />

Hp,E4418A Digital Power Meter<br />

*100kHz~50GHz<br />

*75GHz~110GHz<br />

Hp,E4418b-001 Power meter, high speed, single channel *9kHz~110GHz<br />

Hp,E4419b-001 Power meter, high speed, dual channel *9kHz~110GHz<br />

*100µW~25mW<br />

*-70dbm~44dbm<br />

*100µW~25mW<br />

*-70dbm~44dbm<br />

*100µW~25mW<br />

*-70dbm~44dbm<br />

Hp,8508A Vector voltmeter 100kHz~2GHz 90dB range<br />

bIR,43 RF Thru-line power meter ∆450kHz~2.3GHz<br />

bIR,4391 In-line digital RF power meter<br />

According to element<br />

bIR,4421 In-line RF power meter<br />

bIR,ApM16 Average reading power meter for pCD GSM & CDMA<br />

1.8MHz~32MHz<br />

25MHz~1GHz<br />

0.4~1GHz<br />

1.7~2.2GHz<br />

BIR,ELEMENT Elements for Model 4391 ∆According to element<br />

MAR,6970 Digital power meter ∆According to sensor<br />

∆100mW~10kW<br />

300mW~1kW<br />

2.5W~25W<br />

COL,DC1500A In-line RF power meter dc~0.5 GHz 100W<br />

WAV,FIT RF power & VSWR meter 70MHz~1GHz 20mW~50W<br />

R&S,NRT-Z43-Z44 Directional power meter<br />

30W<br />

200MHz~4GHz<br />

R&S,NRT power reflection meter 30W<br />

* Sensor Dependant<br />

# Element Dependant<br />

Model Type Frequency Power<br />

Hp,8481A<br />

1µW~100mW<br />

10MHz~18GHz<br />

Hp,8484A 0.1nW~10µW<br />

Hp,E9300A<br />

0.1nW~100mW<br />

HP,E9300B<br />

Power Sensor<br />

10Mhz~18GHz<br />

0.1nW~25mW<br />

HP,E9300H 10nW~1W<br />

Hp,8485D 50MHz~26.5GHz 100pW~10µW<br />

RS,FSH-Z1 1.8MHz~26.5GHz 300mW~1kW<br />

> NEW<br />

HP 8508A Vector Voltmeter<br />

Hp,8508A AU<br />

Narrowband measuring technique gives a range of over 90dB and a<br />

sensitivity of 10µV to trace the smallest signal. Measures the phase<br />

difference between its two input channels with at least 0.1º resolution over<br />

a full 180°~-180° range, so they can be used for another complete set of<br />

measurements such as electrical length, phase distortion, or impedance.<br />

100kHz~1GHz with high impedance inputs. 300kHz~2GHz with 50Ω inputs.<br />

Circuit probing to facilitate the design process. Easy programming for ATS’s.<br />

Narrowband measurement capability for high sensitivity applications.<br />

Agilent E4418B Series Power Meter<br />

Hp,E4418b-001 AU<br />

Digital power meter. battery or mains powered. 100µW - 25W (-70dbm<br />

~+44dbm), 9kHz~18GHz (depending on power sensor), 4 digit display<br />

- watts, dbm, db (rel). power sensor required, select and specify when<br />

ordering.


HP E4419B Series Dual Channel Power Meter<br />

Hp,E4419b-001 AU<br />

battery or mains powered dual channel digital power meter. 100µW~25W<br />

(-70dbm~+44dbm), 9kHz~18GHz (depending on power sensor), 4 digit<br />

display - watts, dbm, db (rel). power sensor required, select and specify<br />

when ordering.<br />

Hioki 3134 Digital Power Meter<br />

HIO,3134 MY<br />

AC line power meter, 3 phase W/V/A 1000kw uses two-wattmeter method for<br />

3 wire systems. Can do 4 wire systems. Digital display plus analogue O/p<br />

for all display values V/A/W/VAR. Watts/VAR can both be O/p together to<br />

derive power factor. Supplied with 2x CT’s 3x volts I/p leads in case.<br />

Hioki 3136 Clamp-on Power Meter<br />

HIO,3136 MY<br />

power meter 3ph, 4 wire. FSD 200/1000kW 1kA 600/3V 200/1000 kVAR<br />

recorder O/p 2V/50Ω 40~500Hz complete with 3 x CT’s 9002 unit will<br />

measure 1ph V, A & W. VA & VAR will need to be calculated. On 3ph it will<br />

measure VAR, VA will need to be calculated.<br />

Fluke 36 True RMS ac/dc Clamp Meter<br />

FLU,36 MY<br />

Jaws accept 1 x 750 MCM (1.2 (3mm)) cable or 2 x 500 MCM, (0.98<br />

(24.6mm)) cables up to 38mmØ. True-rms responding. Display 3.5 digit,<br />

2000 count. Rugged design. AC current(45~400Hz), range 600A/200A,<br />

resolution 1A/.1A, accuracy 10~600A ±(2%+3) or 0.5~200A ±(2%+5), crest<br />

factor 2


RF & MICROWAVE<br />

24<br />

pOWer meterS & SenSOrS - rf<br />

> NEW<br />

HP E9300A Power Sensor for HPE4416/18 Power Meters<br />

Hp,E9300A AU/MY<br />

For HpE4416/HpE4418 power meters. 10MHz~18GHz frequency range.<br />

1nW~100mW (-60~+20dbm) power range. 320mW max average power<br />

handling (+25dbm), 2W (+33dbm) peak power ( NEW<br />

Agilent Power Sensor 1µW~25W, 10MHZ~8GHz<br />

Hp,E9300b AU<br />

power sensor for Hp EpM series power meters. E-series average power<br />

sensor. 10MHz~18 GHz, 1µW~25W (-30dbm~+44dbm).<br />

> NEW<br />

HP 8485D Power Sensor 100pW~10uW, 50MHz~26.5GHz<br />

Hp,8485D AU<br />

power Sensor 100pW to 10uW, 50MHz to 26.5GHz.<br />

> NEW<br />

Rohde & Schwarz Power Sensor for RS,FSH 10MHz~8GHz<br />

RS,FSH-Z1 AU<br />

power sensor for RS,FSH 10MHz~8GHz. 200pW~200mW<br />

(-67dbm~23dBm).<br />

HP E9300H Power Sensor 10nW~1W, 10MHz~18GHz<br />

Hp,E9300H AU<br />

power sensor for Hp EpM series power meters. E-series Average power<br />

Sensor. 10 MHz~18 GHz, 10nW~1W (-50dbm~+30dBm).<br />

HP 8481A 10MHz~18GHz Power Sensor for HP43X Series<br />

Meters<br />

Hp,8481A AU<br />

For Hp436A, HpE4418b & HpE4419b. 10MHz~18GHz, 1µW~100mW.<br />

HP 8484A 10MHz~18GHz Power Sensor<br />

Hp,8484A AU<br />

power sensor 10MHz~18GHz, 0.1nW~10µW. Complete with Hp,11708A<br />

30dB reference attenuator.<br />

Marconi 6910 Power Sensor<br />

MAR,6910 MY<br />

Frequency range 10MHz~20GHz. power range -30dbm~20dbm<br />

(1μW~100mW). Max RF i/p 25dbm (300mW) CW 42dbm (15W) peak<br />

for 2μs. Sensing element semiconductor thermocouple. VSWR 1.25<br />

10MHz~30 MHz, 1.1 30MHz~2GHz, 1.18 2~16GHz, 1.28 16~18 GHz, 1.4<br />

typical 18~20GHz. Linearity factor provided with sensor. Accuracy ±0.5% at<br />

25C between 10 & 20dBm. Improves by a factor of 10 for each lower rang.<br />

Calibration factor provided with sensor. Accuracy uncertainty provided with<br />

sensor. Resolution 0.01%. RF connector precision N-type (M) 50Ω.<br />

Marconi 6912 Power Sensor<br />

MAR,6912 MY<br />

Frequency range 30kHz~4.2GHz. I/p power range 30dbm (1μW) to 20dbm<br />

(100mW).<br />

Marconi 6913 Power Sensor<br />

MAR,6913 MY<br />

Frequency range 10MHz~26.5GHz. I/p power range 30dbm (1μW) to 20dbm<br />

(100mW). Max 25dbm (300mW) CW, 42dbm (15W) peak for 2μs. Sensing<br />

element semiconductor thermocouple. VSWR 1.40 10MHz~50MHz, 1.15<br />

50MHz~100MHz, 1.10 100MHz~2GHz, 1.15 2~12.4GHz, 1.20 12.4~18GHz,<br />

1.25 18~26.5GHz. Calibration factor provided at 1GHz intervals (500MHz<br />

intervals above 20GHz) with each sensor. Accuracy uncertainty provided<br />

with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5% at<br />

100mW, decreasing by 0.005% per 1mW.<br />

Marconi 6920 Power Sensor<br />

MAR,6920 MY<br />

High sensitivity diode sensor. Frequency range 10MHz~20GHz. I/p power<br />

range 70dbm (0.1nW) to -20dbm (10μW), max 26dbm (400mW) CW<br />

+30dbm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR<br />

1.4~1.2 10~40MHz, 1.20 40MHz~10GHz, 1.35 10~18GHz, 1.40 typical<br />

18~20GHz. Calibration factor provided at 1GHz intervals with each sensor.<br />

Accuracy uncertainty provided with each sensor.<br />

Marconi 6923 RF Power Sensor<br />

MAR,6923 MY<br />

High sensitivity diode sensor. Frequency range 10MHz~26.5GHz. I/p<br />

power range -65dbm (0.3nW) to -20dbm(10μW), max 26dbm (400mW)<br />

CW, +30dbm (1W) peak for 2μs. Sensing element Shottky barrier diode.<br />

VSWR 1.4 10~40MHz, 1.15 40~100MHz, 1.12 0.1MHz, 1.17 2~8GHz, 1.30<br />

8~18GHz, 1.50 typical 18~26.5GHz. Calibration factor provided at 1GHz<br />

intervals with each sensor. Accuracy uncertainty provided with each sensor.<br />

Resolution 0.01%. Linearity factor provided with each sensor. Accuracy<br />

±1% between -30 & -20dbm. RF connector type N (M) precision 50Ω.


AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

rf attenuatOrS<br />

Model Type Attenuation (dB) Frequency (GHz) Power Max (W)<br />

Hp,8494b-8496b<br />

121<br />

Hp,8494b 11<br />

Coaxial step attenuator<br />

Hp,8495b 70<br />

Hp,8494/5b 81<br />

dc~18<br />

Hp,8495D Step attenuator 70 dc~26.5<br />

WEI,33-10-34<br />

WEI,46-03-34 3<br />

Fixed<br />

WEI,46-06-34 6<br />

10 dc~8 25<br />

WEI,34-30-34 30 dc~4 24<br />

WEI,46-10-34 10<br />

WEI,46-20-43 20<br />

WEI,82-30-34 Coaxial attenuator 30 dc~3 1000<br />

WEI,AS6 Calibrated attenuator 3<br />

WEI,AS20 Variable attenuator 30 dc~26.5 2<br />

dc~18<br />

WEI,M2020 Attenuator 20 dc~18<br />

bIR,25A-10 Fixed 10 dc~4 25<br />

NAR,705-69 Attenuator 30 dc~18 25<br />

Weinschell 33-10-34 25 W 10dB 8.5GHz RF Attenuator<br />

WEI,33-10-34 AU<br />

10db, 25W, dc~8GHz. Type N connectors.<br />

Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator<br />

WEI,34-30-34 AU<br />

30db, 25W, dc~4GHz. Type N connectors.<br />

Weinschell 46-03-34 50W 3dB 18GHz RF Attenuator<br />

WEI,46-03-34 MY<br />

Weinschell 46-06-34 50W 6dB 18GHz RF Attenuator<br />

WEI,46-06-34 MY<br />

DC - 18GHz, 6 db, average power 25W, 200W peak. Type N connector.<br />

Weinschell 46-10-34 50W 10dB 18GHz RF Attenuator<br />

WEI,46-10-34 MY<br />

DC - 18GHz, 10 db, average power 25W, 200W peak. Type N connector.<br />

Weinschell 46-20-43 25W 20dB 18GHz RF Attenuator<br />

WEI,46-20-43 AU/MY<br />

DC~18GHz, 20db, 25W. Type N connectors.<br />

> NEW<br />

Weinschel 82-30-34, 30dB 1000W 3GHz Coaxial Attenuator<br />

WEI,82-30-34 AU<br />

30db 1000W 3GHz Coaxial Attenuator. DC to 3GHz.<br />

Weinschell AS6 Calibrated Attenuator Set<br />

WEI,AS6 MY<br />

Frequency range DC-18GHz, set consists of 4 different nominal value 3, 6,<br />

10 & 20db. Connector type N per mil-STD-348, power rating 5W.<br />

Weinschell AS20 Precision Attenuator Set<br />

WEI,AS20 AU<br />

DC~26.5GHz. Attenuator values 6,10,30 db. Average power 2W.<br />

3.5mm connectors.<br />

Weinschell M2-20 Attenuator<br />

WEI,M2-20 MY<br />

20 db attenuator. DC to 18GHz, double male N type<br />

HP 8494B/8496B Attenuator Set 121dB x 1dB<br />

Hp,8494b-8496b AU<br />

Coaxial step attenuator set. DC-18GHz. 0.11db in 1db steps and 10-110<br />

db in 10db steps. Comprises a connected set of types 8494b & 8496b with<br />

11716A rigid interconnect kit. Type N(f) connectors.<br />

HP 8494B 11 x 1dB 18GHz Coaxial Step Attenuator<br />

Hp,8494b AU<br />

DC~18GHz. 0~11db in 1db steps. 1W average power handling. Option<br />

001. Type N(f) connectors.<br />

HP 8495B 70dB x 10dB Coaxial Step Attenuator<br />

Hp,8495b AU<br />

DC~18GHz. 0~70db in 10db steps.<br />

HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB<br />

Hp,8494/5b AU/MY<br />

DC~18GHz. 0~11db in 1db steps. 11~81db in 10db steps. Comprises a<br />

connected set of types 8494b & 8495b. Type N(f) connectors.<br />

HP 8495D 70dB 26.5GHz Step Attenuator<br />

Hp,8495D AU/MY<br />

70db step attenuator in 10db steps. Frequency range dc~26.5GHz. Max<br />

continuous power 1W. Note attenuator uses 3.5mm connectors.<br />

RF & MICROWAVE<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 25<br />

1<br />

50<br />

25


RF & MICROWAVE<br />

LOW FREQUENCY<br />

26<br />

rf attenuatOrS<br />

BIRD 25-A-MFN-10 10dB 25W 4GHz ATTENUATOR<br />

bIR,25A-10 AU<br />

RF Attenuator, DC~4GHz, 10db, 25W, .<br />

Bird 808 RF Co-axial Resistor 25W 50Ω<br />

bIR,8080 MY<br />

50Ω, 25 W, DC-3500MHZ. Dummy Load.<br />

filterS<br />

Krohn-Hite 3550 Bandpass Filter<br />

KRO,3550 AU<br />

band pass, band reject, low pass, high pass filter. Frequency range 2Hz~200kHz. bandwidth 2Hz~3MHz. Max attenuation 62db. Slope 24db per octave.<br />

rf acceSSOrieS<br />

HP 85021A RF Directional Bridge<br />

Hp,85021A AU<br />

For Hp,8757A scalar network analyser.<br />

HP 11667A Power Splitter<br />

Hp,11667A AU<br />

For Hp,8757A scalar network analysers, dc~18GHz, 0.5W max. N (F)<br />

connector on all ports.<br />

HP X281A WR-90, 1-079 to N(F) Adaptor<br />

Hp,x281A AU<br />

8.2~12.4GHz waveguide to type N (F) adaptor.<br />

HP P281B-013 WR-62, 1-089 to Coax Adaptor<br />

Hp,p281b AU<br />

12.4~18GHz waveguide to type N(f) adaptor.<br />

HP S281A WR-284 to N(F) Adaptor<br />

Hp,S281A AU<br />

2.6~3.95GHz waveguide to type N (F) adaptor.<br />

RF Connector Kit N, BNC, TNC, SMA, APC7<br />

<strong>TR</strong>,RF-CONN AU<br />

RF connection adaptors. Comprises 10 couplers with interchangeable<br />

connectors; 3 x N, bNC, SMA, & 1 x TNC, all (M) & (F). Includes ApC~7 to<br />

N (F) adaptor.<br />

lf Signal generatOrS<br />

Tektronix ASG100 Audio Generator<br />

TEK,ASG100 MY<br />

Dual CH for stereo applications. balanced i/p & o/p. Connects in-line for<br />

easy test signal insertion. Quick identification of insertion pt with voice ID.<br />

Short duration audio test sequence for rapid automatic checkout of audio<br />

lines. Single button selection of line-up tone. Manual mode allows selection<br />

of freq & amplitude. RS-232 for remote control.<br />

diStOrtiOn analySerS<br />

HP 8903B-010-051 Audio Analyser<br />

Hp,8903b AU<br />

Audio analyser for communications and other applications. Measures<br />

distortion, sinad, signal-to-noise, ac V, dc V, frequency. Low distortion<br />

programmable sine wave source. Frequency range 20Hz~100kHz. Optional<br />

400Hz high pass and CCITT weighting filters fitted.<br />

Narda 705-69 69 x 1dB GHz Attenuator<br />

NAR,705-69 MY<br />

Step Attenuator. 0 - 69db in 1db steps. Frequency range DC - 18GHz<br />

HP 11692D Dual Directional Coupler<br />

Hp,11692D MY<br />

Frequency range 2~18GHz.<br />

HP 778D Dual Directional Coupler<br />

Hp,778D AU<br />

Frequency range 100MHz~2GHz.<br />

HP 908A Coaxial Termination<br />

Hp,908A AU<br />

DC~4GHz. Max power 0.5W average.<br />

HP 11852A Min Loss Pad 50 ~75Ω<br />

Hp,11852A AU<br />

Low SWR min loss pad for use with 50Ω network analysers or other<br />

instruments to allow connection to 75Ω cables and devices.<br />

Radiall R-404850 RF Termination<br />

RAD,R-404850 AU<br />

RF load. 100W, 50Ω, dc~4GHz. Type N (M).<br />

Flann 1713320 Waveguide Directional Coupler<br />

FLA,1713320 AU<br />

20dB.<br />

Genrad 1390B Random Noise Generator<br />

GR,1390-b AU/MY<br />

Frequency range 5Hz~5MHz, range selectable 20kHz, 500kHz & 5MHz.<br />

Output level 3V, 2V, 1V for each frequency range respectively. Gaussian<br />

output. Frequency response 1db, 20Hz~20kHz. pink noise filter optional.<br />

Trend Type 3 Distortion Generator<br />

<strong>TR</strong>E,TYpE 3 AU<br />

Distortion generator.


NEW<br />

Rohde & Schwarz EFA TV Test Receiver 43<br />

RS,EFA43 AU<br />

DVb-T test receiver, fully compatible with the ETS300 744 standard, receives,<br />

demodulates, decodes and analyzes OFDM (orthogonal frequency division<br />

multiplex) signals. All key parameters for demodulating the receive signal<br />

can be selected automatically or manually. Features, 7MHz SAW filter.<br />

6MHz, 7MHz or 8MHz operating bandwidth. 2K or 8K OFDM modulation.<br />

QpSK, 16QAM or 64QAM constellation diagram. 1/2, 2/3, 3/4, 5/6 or 7/8<br />

code rate. 1/4, 1/8, 1/16 or 1/32 guard interval. Hierarchical demodulation.<br />

Reed-Solomon error correction 204/188.<br />

> NEW<br />

Promax TV Explorer Prodig-5<br />

pRO,pRODIG-5 AU<br />

For the installation, maintenance and surveillance of terrestrial, satellite and<br />

cable TV systems. Automatically provides information about the channels<br />

available in the network and their quality. Displays analogue and digital<br />

channel picture. Includes a high resolution spectrum analyser function and<br />

MPEG decoding. Foxtel approved.<br />

Promax Prolink 4C Premium Analogue/Digital TV Test Set<br />

pRO,pROLINK4C-pREM AU<br />

Measures terrestrial, satellite and cable TV systems including analogue and<br />

digital VHF & UHF bands. built in colour monitor provides measurement<br />

readout and can be used to display video signal. Measurement functions<br />

include spectrum analysis, direct signal level readout, carrier to noise,<br />

channel power, digital carrier to noise, digital bit error ratio (BER) and digital<br />

QAM constellation. DVb digital TV channel identifier. Logs to pC and<br />

includes software for remote control and channel plan management.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

tv teSt equipment<br />

Tektronix 1741 Vectorscope/Waveform Monitor<br />

TEK,1741 AU<br />

pAL waveform monitor and vectorscope for television and video use.<br />

Unaohm S20 & Datum 10 Digital TV Meter Combo Meter<br />

UNA,DATUM10-S20 AU<br />

Comprises S20 Satellite digital and analogue television bit error rate meter<br />

and Datum 10 terrestrial digital and analogue television instrument.<br />

Barco Quasar Modulator<br />

bAR,MODULATOR AU<br />

Digital television signal converter. Rack mounted. Supports a full range of<br />

variable data rates, signal bandwidths and constellations. Complies with<br />

ITU-TJ.83 standards, annex A (DVb), b (open cable) & C Japan. ASI input<br />

interface (with active loop-through). Variety of input interfaces available. bit<br />

stuffing on/off and pCR re-stamping. Static pID filtering. Tuneable or fixed<br />

output RF frequency. IF loop. Front panel RF testpoint (-20db). 60dbmV<br />

(rms) output level. Front panel LCD and buttons for easy set-up. Full remote<br />

control and diagnostics with ROSA management. back-up and automatic<br />

level control available with ROSA.<br />

TELEVISION TEST EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 27


DATA, NETWORK & TELECOMMUNICATIONS<br />

28<br />

telecOmmunicatiOnS<br />

> NEW Nettest Lite 3000E Signalling Analyser for<br />

Telecommunications Systems<br />

GNE,L3000E-ND AU<br />

Simultaneous monitoring in both directions of 2Mb/s pCM lines. Tests framed<br />

Nx64 Kb/s & unframed 2Mb/s pCM systems. Remote operation with MS<br />

Windows. Frame Relay installation testing, trouble shooting & decode. Alllayer<br />

protocol analysis and decode options for ISDN. ISDN Call Emulation<br />

option provides the necessary functionality for testing ISDN connections,<br />

can setup and receive ISDN calls with user-specified parameters.<br />

Anritsu ME538MLA TX & RX Microwave Link Analyser<br />

ANR,ME538M AU<br />

Measures group delay, modulator/demodulator linearity & sensitivity,<br />

differential gain & phase, IF/bb amplitude response, IF/bb return loss,<br />

frequency spectrum & deviation, am to pm conversion coefficient, power,<br />

gain attenuation and dc characteristics. Features: LED display, autorange<br />

CRT, push button parameter selection and remote monitoring. 70/140MHz<br />

bands: 83.333, 250, 500kHz & 2.4, 3.58, 4.43, 5.6, 8.2, 12.39MHz.<br />

Nettest EPE06/7 2,8,34,140 MPPS BERT<br />

GNE,EpE06/7 AU<br />

pCM bERT tester for 2, 8, 34 & 140 Mb pCM systems. performance<br />

according to G.821 with BNC type connectors. For unbalanced inputs.<br />

Nettest MPA7400 Multichannel Signalling Protocol Analyser<br />

GNE,MpA7400 AU<br />

Multichannel telecom protocol analyser for detailed analysis of signalling<br />

systems such as SS7. Able to analyse 4 channels at the same time. Some<br />

emulation capability. Additional protocol decodes available on request.<br />

Unit is currently set up to handle signalling analysis for cellular telephone<br />

exchanges.<br />

Trend Aurora Sonata BRA/PRI ISDN Test Set<br />

<strong>TR</strong>E,AURORA-SONATA AU<br />

bRI/pRI/pOTS test set. provides simulation and monitor capabilities for<br />

Primary Rate, Basic Rate, and POTS services. Provides decoding of ETSI<br />

ISDN protocols. Has S,U,E1 and RJ11 pOTS interfaces. battery operated<br />

hand held device.<br />

W&G/Acterna IBT-10U Basic Rate ISDN Test Set<br />

WG,IbT-10U AU<br />

performs bERT, protocol analysis to level 3 includes both S & U interface.<br />

Features include: NT simulation, telephone and tracer function, x.25 on D<br />

channel and B channel, measurement of supply voltages.<br />

Nettest Lite 3000E Signal Analyser<br />

GNE,L3000E AU<br />

Signaling analyzer for telecommunications systems. Framed Nx64 Kbps<br />

and unframed bERT testing, in-service and out-of-service error performance<br />

measurements G.821/G.826/M.2100. balanced and unbalanced interface.<br />

Has functionality for G.703, AbIS, SS7, and ISDN for use in both wired and<br />

wireless (cellular GSM) applications. Provides comprehensive test and<br />

measurement of data transmission lines on RS232/V.24 async & sync, x.21/<br />

V.11, V35, RS422/485/449/V.36, RS-530, DCE or DTE. Detailed analysis<br />

and graphical representation on large colour display. Remote operation with<br />

MS Windows.<br />

Digital Lightwave NIC 2.5G STM16 2.5Gb SDH Test Set<br />

DLW,NIC2.5G AU<br />

Portable analyser with touch screen PC. Testing at SDH rates of<br />

STM0/1/4/16 (52,155,622Mb/s & 2.5Gb/s). Tests pDH at E1,E3, E4, DS1 &<br />

DS3 (2,8,140,1.5 & 45Mb/s). Dual wavelength (1310/1550nm). SC Optical<br />

connectors. Tests include BERT, level, protocol decoding & analysis and<br />

ATM analysis. Complete in portable hardcase.<br />

Digital Lightwave NIC10G STM16/64 SDH Analyser<br />

DLW,NIC10G AU<br />

Network information computer. Verifies and qualifies the performance of<br />

OC-192c/OC-48c SONET, STM-64/STM-16 (10/2.5Gbps) SDH and DWDM<br />

telecommunications networks. Optical interfaces (1550/1310nm for STM16<br />

& 1550nm for STM64). Includes concatenated payload support and OC-<br />

48/STM-16 add/drop. 10.4” active matrix touch screen GUI operation.<br />

Measures optical power and frequency. pCMCIA slots for memory cards<br />

and peripherals.<br />

Digital Lightwave NICPlus 10G SDH Tester with Gb Ethernet<br />

DLW,NICpLUS10G AU<br />

portable Gb/OC-192/STM-64 Network Information Computer (5 slot<br />

chassis). Multirate interface for STS-1 OC-1/3/3c/12/12c/48/48c STM-<br />

0e/1e/0/1/1c/4/4c/16/16c and interface for OC-192/192c STM-64/64c with<br />

the ability to monitor down to the STS-1/STM-0 level inside of any supported<br />

optical rate. Use to verify & qualify the performance of SDH & DWDM & GbE<br />

telecomm networks. Electrical & optical interfaces (1550nm for 10G, all other<br />

rates 1310/1550). Includes concatenated payload support & OC-48/STM-16<br />

add/drop. G.709/975 OTU 1 / OUT 2 FEC software installed 10.4 inch active<br />

matrix touch screen GUI operation. Measures optical power and frequency.<br />

pCMCIA slots available for memory cards and peripherals.<br />

Fluke 990DSL CopperPro Telecom Line & DSL Test Set<br />

Analyser<br />

FLU,990DSL AU<br />

CopperPro wide range Plain Old Telephone Services (POTS) fault location<br />

and line qualification capabilities. Includes Wideband/TDR option which<br />

adds high frequency transmission testing and qualification functions for<br />

services like ADSL, HDSL, HDSL2, HDSL4, ISDN, T1, E1 and DDS. TDR<br />

feature adds precise fault location and analysis. Includes TN2100 remote<br />

terminator.<br />

W&G/Acterna ANT 20 SDH/PDH Analyser<br />

WG,ANT20 AU<br />

Interfaces for pDH data streams at 2, 8, 34, & 140Mb/s, electrical and optical<br />

interfaces for SDH at STM1 (155Mb/s). Jitter and wander generators and<br />

analyser options are fitted. Internal PC with FDD for transferring results.<br />

Serial, parallel, keyboard and pen interfaces.<br />

Aegis GPset Telecom Pair ID & Intercom<br />

AEG,GpSET AU<br />

For telecommunications cable work. Typically used by Telstra contractors.<br />

Intercom function available on live or unpowered lines.


NEW<br />

Fluke Networks Etherscope Gigabit W-LAN Analyser<br />

FLU,ETHERSCOpE-WLAN AU<br />

Etherscope extended kit full duplex 10/100/gigabit LAN & WLAN 802.11a/<br />

b/g analyser. Handheld analyser for discovery of network elements and<br />

fault location. Discovers devices by Ip subnets, NetbIOS domains, and Ipx<br />

networks. VLAN discovery shows interface status, connected host details,<br />

and trending data. Allows measurement of device details and statistics.<br />

Complete with cable ID accessory for tracking cable routes.<br />

> NEW<br />

Fluke Nettool LAN Analyser<br />

FLU,NETTOOL AU<br />

VoIp monitoring. bi-directional LAN test tool. Diagnose VoIp phone bootup<br />

problems, call control and measure key call quality metrics. Compatible<br />

with IP phones employing either SIP or SCCP call control protocols. VoIP<br />

Log displays call control events, QoS configuration, and call quality metrics.<br />

boot Log displays key boot events such as DHCp address acquisition, DNS<br />

lookup of call servers and gateways, downloading of operating files, and call<br />

server registration. Inline testing of LANs at the workstation level. Tool is<br />

plugged in-line between workstation and LAN. provides indications of NIC<br />

and hub functionality, cable connectivity, and protocol compatibility between<br />

LAN and workstation. Use as a first line fault finding tool for IT departments.<br />

Airmagnet Portable 802.11 a/b/g Survey System<br />

AIR,AIRMAGNET-SURVEY AU<br />

portable wireless network survey tool for 802.11a, 802.11b and 802.11g<br />

wireless networks (5 & 2.4GHz). provides mapping of wireless network<br />

coverage with optional GpS location facility. pre-loaded on laptop computer<br />

with approved wireless network card.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

lan analySerS/management<br />

Airmagnet Portable 802.11 a/b/g Wireless Network Analyser<br />

AIR,AIRMAGNET-<strong>TR</strong>IO AU<br />

portable wireless network analyser for 802.11a, 802.11b and 802.11g<br />

wireless networks (5 & 2.4GHz). Validates WEp, 802.1x, LEAp, TKIp,<br />

MIC, VPNs. Provides security policy validation and intrusion detection.<br />

Detects denial of service attacks. provides active performance analysis and<br />

identifies and pinpoints WLAN Faults. Includes Find Tool for tracking down<br />

rogue devices and 70+ configurable alarms with expert advice. pre-loaded<br />

on p3 notebook computer.<br />

Airmagnet Portable Wireless Network Analyser<br />

AIR,AIRMAGNET-pRO AU<br />

Validates WEp, 802.1x, LEAp, TKIp, MIC, VpNs. provides security policy<br />

validation and intrusion detection. Detects denial of service attacks. provides<br />

active performance analysis and identifies and pinpoints WLAN Faults.<br />

Includes Find Tool for tracking down rogue devices and 70 + configurable<br />

alarms with expert advice. built-in site survey utility with GpS support.<br />

Fluke Networks Etherscope Gigabit LAN Analyser<br />

FLU,ETHERSCOpE-Ex AU<br />

Etherscope extended kit full duplex 10/100/Gb LAN analyser. Handheld<br />

analyser for discovery of network elements and fault location. Discovers<br />

devices by Ip subnets, NetbIOS domains, and Ipx networks. VLAN<br />

discovery shows interface status, connected host details, and trending data.<br />

Allows measurement of device details and statistics. Complete with cable ID<br />

accessory for tracking cable routes.<br />

Fluke Optiview Pro Gigabit 10/100/Gigabit LAN Analyser<br />

FLU,OpTIVIEW-GIG AU<br />

FLU,OpTIVIEW NZ<br />

provides network analysis on 10/100/Gigabit Ethernet networks (multimode<br />

fibre & copper). Active discovery in switched networks, full 7 layer analysis,<br />

fully automatic Ip configuration even without DHCp, address-to-name<br />

mapping, packet capture and decode, SNMp device analysis, RMON II<br />

traffic analysis. Gigabit testing capabilities, and basic cable testing (wiremap,<br />

return loss, etc).<br />

HP J3446C 10/100 Ethernet Analyser<br />

Hp,J3446C AU<br />

Has RJ45 and AUI ports. AUI ports allow fibre or co-ax connections to be<br />

made with appropriate adaptor (adaptor not supplied). For use with HP<br />

internet advisor undercradles for FDDI or similar analysis.<br />

DATA, NETWORK & TELECOMMUNICATIONS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 29


DATA, NETWORK & TELECOMMUNICATIONS<br />

30<br />

Network problem solver? Meet your new assistant.<br />

EtherScope<br />

Network Assistant<br />

lan analySerS/management<br />

HP J2524A FDDI Under Cradle<br />

Hp,J2524A AU<br />

For the Hp,J2302A or Hp,J2523A/b. Includes Tp/pMD on STp/Db-9 or<br />

UTp/RJ-45, 32Mb data.<br />

HP J2523A Ethernet/Token LAN Analyser<br />

Hp,J2523A AU<br />

Housed in a ruggedised laptop style colour computer. Includes Hp’s latest<br />

Drill Down Expert Software.<br />

Network General Sniffer - Ethernet /Token Ring<br />

NG,SNIFF-COMb AU<br />

Housed in a colour Toshiba T6600. Analyser provides 3 applications for<br />

network analysis and monitoring. protocol interpretation for over 140<br />

protocols, monitoring features, and expert analysis to help identify LAN<br />

problems. Oracle database decodes also available.<br />

Network General 10/100Mb/s Ethernet Protocol Analyser<br />

NG,SNIFF-10/100 AU<br />

10mbps and 100mbps Ethernet protocol analyser for 10/100 base<br />

T networks. Unit supplied with RJ45 connections only.<br />

Network General Sniffer WAN Interface<br />

NG,SNIFF-WANpOD AU<br />

Enables the Network General Sniff-pro98 to perform WAN as well as LAN<br />

analysis. With interface and cables for RS232/V24, V35, RS449/422 and<br />

x.21. Must be used with NG,SNIFF-pRO98. performs E1/ISDN primary<br />

rate analysis.<br />

N E T W O R K S U P E R V I S I O N TM<br />

Introducing the EtherScope Network<br />

Assistant – your eyes into the network to<br />

help you spot problems and solve them<br />

faster than ever. You don’t have time for trial<br />

and error. Or methods that only provide part<br />

of the picture. That’s why Fluke Networks’ new<br />

EtherScope analyzer, with its immediate<br />

discovery and fast diagnostics, helps you<br />

quickly isolate urgent problems on your gigabit<br />

network as well as those nagging issues that<br />

may be keeping it from performing at optimum<br />

level. Fast. Accurate. EtherScope.<br />

Your network assistant is waiting<br />

to show you what it can do to help<br />

make your job easier. Just go to<br />

www.flukenetworks.com/EtherScope<br />

and take a tour of the virtual demo.<br />

W&G/Acterna DA-30 Dual Protocol Analyser<br />

WG,DA-30 AU<br />

Easy to use Windows-based interface with in-built trackball. provides<br />

measurement of physical characteristics of interfaces, protocol analysis of<br />

LAN and WANs, testing of LAN/WAN interconnection devices, simultaneous<br />

analysis of any combination of LANs and WANs. Ethernet and Token Ring<br />

interface complete with all major layer protocol suites. WAN configuration:<br />

V.35, x.21 with “high speed” WAN feature module allowing speeds up to<br />

2Mbps. Includes 16/4Mbps Token Ring interface, Ethernet,HS-WAN, V35-<br />

V28 & x21 interfaces. pAM module included.<br />

W&G/Acterna Domino Gigabit<br />

WG,GIGAbIT AU<br />

For monitoring, troubleshooting, and simulation of Gigabit Ethernet networks.<br />

provides full line rate, full duplex analysis of Gigabit Ethernet networks. All<br />

transmit, capture, filtering, and statistics are provided at full line rate. Expert<br />

analysis software provides easy diagnosis of network faults, and decodes<br />

over 300 protocols. Link configuration status is detected automatically and<br />

equipment auto configures itself to suit the detected status. Provided with<br />

hot swappable modules for single mode and multi mode fibre interfaces<br />

(Lx & Sx interfaces). Complete with laptop computer configured for the<br />

analyser.


Nettest Winpharaoh LAN/WAN Analyser<br />

GNE,WINpHARAOH AU<br />

Capable of 10/100Mbps ethernet and up to 2Mb WAN with the following<br />

interfaces: V.35, RS-232, RS-449, EI and V.11. pRI and bRA ISDN ability.<br />

Report writing software installed for quick overview of network status.<br />

Nettest Winpharoah 2 LAN/WAN Analyser<br />

GNE,WINpHARAOH2 AU<br />

Capable of 10/100Mbps Ethernet and up to 2Mb WAN with the following<br />

interfaces: V.35, RS-232, RS-449, and V.11/x.21. Has bERT testing<br />

for WAN. Report writing software installed for quick overview of network<br />

status.<br />

Spirent/Netcomm Smartbits SMB200 Router Tester<br />

SpI,SMb200-10/100 AU<br />

4 port 10/100 ethernet/STM1 ATM system for determining router performance<br />

including latency, latency variation and jitter. Can be used to load network<br />

with specific definable traffic to determine routing performance and discover<br />

throughput bottlenecks. System includes 4 x ML7710 10/100 interface<br />

cards.<br />

HP 4951C 19.2Kbps Protocol Analyser<br />

Hp,4951C AU<br />

Serial data and protocol analyser. 50~19,200 baud data transfer rates<br />

for monitoring, simulating and triggering. Data codes: ASCII, EbCDIC,<br />

bAUDOT, six bit transcode (SbT), IpARS and EbDIC. protocols: x.25. bSC,<br />

HDLC, SDLC, IpARS and user definable. Error checking: CRC-CCITT,<br />

CRC-6/12/16, LRC, parity and block error rate testing (bERT), 5, 6, 7 or 8<br />

bit per character parity, 1,1.5 or 2 stop bits. Full ASCII keyboard, up to 63<br />

triggers, 32kb buffer memory, 618kb integral microfloppy drive, video output,<br />

separate printer output. Complete with Hp,18179A RS-232C/V24 interface<br />

with full breakout box.<br />

HP 4957A 64Kbps Protocol Analyser<br />

Hp,4957A AU<br />

protocol analyser. For up to 64kb/s (option included for asynchronous 8bit<br />

and NRZ/NRZI bit oriented protocols up to 256 kbps). protocols include<br />

ISDN Q.921, x.25, SDLC, HDLC, IpARS, bSC, ASYNC, and most character<br />

synchronous protocols, (option included for x.21). bERT function. Data<br />

codes ASCII, EbCDIC, bAUDOT, 6 bit transcode (SbT), IpARS, EbCD and<br />

HEx. 32 kb non-volatile memory, 786 kb volatile memory, 613kb microfloppy,<br />

128kb non-volatile RAM disk. Complete with RS-232C, RS-449 and V35<br />

interfaces, printer and video outputs.<br />

Nettest Fastnet Probe<br />

GNE,Fp1601SR AU<br />

Fastnet probe for Frame Relay. Provides monitoring and statistical<br />

information for Frame Relay Networks. Complete with interface cable and<br />

management software.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

lan/Wan analySerS<br />

Spirent Netcomm Smartbits SMB600 Mainframe<br />

SpI,SMb600 AU<br />

Mainframe for router test system for determining router and network<br />

performance including latency, latency variation and jitter. Can be used to<br />

load network with specific definable traffic to determine routing performance<br />

and discover throughput bottlenecks. Supplied with standard software and<br />

30 version of Smartflow application. Requires appropriate interface cards.<br />

Spirent Smartbits LAN-3101A interface for SMB600/6000<br />

Chassis<br />

SpI,SMb600-3101A AU<br />

Spirent Smartbits LAN-3201B Gigabit card for SMB600/6000<br />

SpI,SMb600-3201b AU<br />

Spirent Smartbits LAN-3310A 2Port Gigabit Card for<br />

SMB600/6000<br />

SpI,SMb600-3310A AU<br />

Spirent Netcomm Smartbits SMB6000 Mainframe<br />

SpI,SMb6000 AU<br />

12 card Mainframe for router test system for determining router and network<br />

performance including latency, latency variation and jitter. Can be used to<br />

load network with specific definable traffic to determine routing performance<br />

and discover throughput bottlenecks. Supplied with standard software<br />

and 30D version of Smartflow application. Requires appropriate interface<br />

cards.<br />

Wan analySerS<br />

HP J2302A 2Mbps WAN Analyser<br />

Hp,J2302A AU/NZ<br />

WAN analyser from 50b/s~2.048Mb/s. Internet Advisor CEpT-E1 and V<br />

series WAN protocol analyser. Includes; RS232/V24, V35, RS449, and<br />

CEpT-E1 analysis to 2Mb/s with bNC connectors. ISDN primary rate<br />

analysis available with Hp,18284A pod. Full monitor and decoding of major<br />

protocols over any channel. Fractional channel or full CEpT-E1. Complete<br />

English decodes with customizable displays, real-time stamp for captured<br />

data or statistics, 100ns resolution. Extensive data-filtering capability.<br />

Real-time statistical analysis, including LAN traffic analysis over WANs.<br />

100% capture performance during full line loading. Simultaneous decodes,<br />

statistics, triggers, and filters. Log to hard disk. Full bit Error Rate tests to<br />

2Mb (including G.821). Over 150 pre-written test included.<br />

HP J2302B 2 Mbps WAN Analyser<br />

Hp,J2302b AU<br />

Internet advisor. WAN analyser from 50b/s~2.048Mb/s. CEpT-E1 and V<br />

series WAN protocol analyser. Includes: RS232/V24, V35, RS449, and<br />

CEpT-E1 analysis to 2Mb/s with bNC connectors. ISDN primary rate<br />

analysis available with Hp,18284A pod. Full monitor and decoding of major<br />

protocols over any channel. Fractional channel or full CEpT-E1. Complete<br />

English decodes with customizable displays. Time stamp for captured data<br />

or statistics, 100ns resolution. Extensive data filtering capability. Real<br />

time statistical including LAN traffic analysis over WANS. 100% capture.<br />

performance during full line loading. Simultaneous decodes statistics,<br />

triggers, and filters. Log to hard drive. Full bit Error Rate tests to 2mb/s<br />

(BERT) including G821. Over 150 prewritten tests included.<br />

DATA, NETWORK & TELECOMMUNICATIONS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 31


DATA, NETWORK & TELECOMMUNICATIONS<br />

32<br />

lan cable teSterS<br />

Fluke DTX1200 Category 6 Cable Certification Tester<br />

FLU,DTx1200 AU/NZ<br />

Cable certification tester. Tests up to 350MHz; Cat6 Autotest time of 12s.<br />

Comes complete with latest cat6 pM-06 peronality modules. Linkware pC<br />

software, and USb cable. Internal memory stores 350 tests. Optional<br />

memory card stores 2,000 tests.<br />

Fluke DTX1800 Category 7 Cable Certification Tester<br />

FLU,DTx1800 AU/NZ<br />

Cable certification tester up to 900MHz; Cat6 Autotest time of 12s. Comes<br />

complete with latest cat 6 pM-06 personality modules, Linkware pC software,<br />

and USb cable. Internal memory stores 350 tests. Tests to Cat 3, 4, 5, 5E,<br />

6 & 7. Included Cat6 heads will test up to category 6. Optional memory card<br />

stores 2,000 tests.<br />

> NEW<br />

Fluke DTX 10 Gig copper Testing and Certification Kit<br />

FLU,DTx-10G KIT AU<br />

Used in conjunction with the FLU,DTx1800. Enables testing and certification<br />

of twisted pair cabling for 10 Gigabit Ethernet deployments - whether it is an<br />

existing Cat 6 or newly installed augmented Cat 6 cabling system. Measures<br />

the performance for 10 Gig and Alien Crosstalk (ANExT and AFExT) in full<br />

compliance with the industry standards to 500 MHz.<br />

Fluke DTX-MFM Multimode Fibre Adaptor for DTX Cable<br />

Analyser<br />

FLU,DTx-MFM AU<br />

DTx1200/1800 multimode fibre interface. Tests fibre installations in local<br />

area networks. Fits in the slot on the back of DTx cable analyser (standard<br />

copper cable adaptors can be connected but not used simultaneously).<br />

provides fibre testing and certification. bi-directional testing at 850nm<br />

& 1300nm at the same time. Measures optical power loss, length, and<br />

propagation delay for multimode fibres. pass/fail results based on common<br />

fibre standards. SC optical connectors. Includes in built visual fault locater.<br />

(VFL)<br />

Fluke DTX-SFM Singlemode Fibre Adapter for DTX Cable<br />

Analyser<br />

FLU,DTx-SFM AU<br />

DTx1200/1800 singlemode fibre interface. Use for testing fibre installations<br />

in local area networks. Fits in the slot on the back of DTx cable analyser<br />

(standard copper cable adaptors can be connected but not used<br />

simultaneously). provides fibre testing and certification. bi-directional<br />

testing at 1310 nm and 1550 nm at the same time. Measures optical power<br />

loss, length, and propagation delay for multimode fibres. pass/fail results<br />

based on common fibre standards. SC optical connectors. Includes in built<br />

visual fault locater. (VFL)<br />

Fluke DSP Personality Module for DSP4X00 series<br />

FLU,DSp-pM AU<br />

personality module for Fluke DSp4x00 cat6 permanent Link heads. RJ45<br />

connector sets (pM-01, pM-06, pM-25) include 2 modules. block connector<br />

sets include one module (pM-12b, pM-13b). Modules available include pM-<br />

06 (most systems), pM-25 (most unshielded systems), pM-01 (legacy), pM-<br />

12b paduit GIGA-pUNCH 110 block, pM-13b Siemon S210 block.<br />

Fluke Networks CableIQ Cable & Network Identification Tool<br />

FLU,CAbLEIQ<br />

CableIQ cable and network tester for twisted-pair, coax, and audio cabling.<br />

Allows troubleshooting connectivity problems and qualify cabling bandwidth<br />

to see whether an existing cabling link is qualified to support 10/100, VoIp<br />

or Gigabit Ethernet. Discovers what is at the far end of any network cable.<br />

Detects speed and duplex settings of attached switches and PCs. Intelligent<br />

wiremap graphically shows distance to faults (e.g., pin 1 break at 31m). Can<br />

also test cable set-up for audio application (intercom/pA). Hand held and<br />

lightweight, powered by 4 x AA Alkaline batteries. Can be used as a signal<br />

source for optional Intellitone cable tracer.


NEW<br />

Fiber Video Display Scope<br />

FLU,FT330 AU<br />

Handheld battery operated video scope for fiber inspection.<br />

> NEW<br />

Fiber Inspection Video Probe X 250 Magnification<br />

FLU,FT350 AU<br />

Connects to a FLU,OpTIFIbER or FLU,FT330 to let you inspect the ends of<br />

fiber optic connectors. 250 x magnification reveals dirt, scratches, and other<br />

defects that can cause poor performance or failures in fiber optic networks.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

fibre OpticS<br />

> NEW<br />

Fiber Inspection Video Probe X 250 & 400 Magnification<br />

FLU,FT650 AU<br />

Fibre probe for use with Fluke Optifiber OTDR or FLU,FT330 handheld video<br />

scope. Has switchable 250 and 400 times magnification.<br />

Fluke FTK200 Optical Fibre Power Meter/Light Source<br />

FLU,FTK200 AU<br />

Comprises light source and power meter. Light source is multi-mode 850nm<br />

& 1300nm (-20dbm into 62.5µm fibre). Stability is ±0.1db per 8h at 25 0 C.<br />

power meter has calibrated measurements at 850/1300nm multi-mode &<br />

1310/1550nm single-mode. 6dbm~-50dbm measurement power with 0.01<br />

resolution & accuracy of ±0.25 at 25 0 C & -10dbm. power meter memory<br />

stores up to 500 results at each wavelength which can be downloaded to PC<br />

with supplied software (also compatible with Fluke Cable Manager used for<br />

the DSp4000/4100 series). ST connector on power meter and light source.<br />

DATA, NETWORK & TELECOMMUNICATIONS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 33


DATA, NETWORK & TELECOMMUNICATIONS<br />

34<br />

fibre OpticS<br />

Fluke Optifibre Multi-mode OTDR<br />

FLU,OpTIFIbER-MM AU<br />

Short range multimode OTDR designed for testing, troubleshooting and<br />

certifying network cabling. 850/1,300nm, 62.5mm (100m launch cable<br />

included) & 50mm (requires launch cable) fibres with SC connectors.<br />

Attenuation deadzone 850nm: 4.5m typical, 5.5m max 1,300nm: 10.5m<br />

typical, 15m max. 3km range for 850nm & 7km range for 1,300nm. Measures<br />

insertion loss and fibre length, allows automatic and manual OTDR analysis<br />

including channel map of connectors. Included LinkWare pC software<br />

documents, reports and manages all test data. Battery operated with colour<br />

display.<br />

Acterna OMK-6 Fibre Optic Power Meter<br />

WG,OMK-6 AU/NZ<br />

OMK-6 optical power meter with multi mode and single mode light sources.<br />

Level measurement is -65~+10dbm. Measurement errors are eliminated<br />

because the power meter automatically detects the wavelength being<br />

transmitted by the light source. Single mode dynamic range with continuous<br />

wave is 58db (approx 145km @ 1310nm & 230km @ 1550nm). Multi mode<br />

dynamic range with continuous wave is 40db (approx 20km at 850nm &<br />

50km at 1310nm).<br />

Acterna OMK-14 Optical Measurement Kit<br />

WG,OMK14 MY<br />

Kit consists of WG,OLS-15 (light source) and WG,OLp-15 (power meter).<br />

WG,OLS-15; 1310nm & 1550nm, o/p; 7dbm (into 9/125µm) mod frequency:<br />

270Hz, 1kHz, 2kHz. WG,OLp-15; 800~1700nm, switchable at; 850, 980,<br />

1310, 1480 & 1550nm. Sensor type InGaAs, suitable fiber type 9/125a~50/<br />

125µm. Mod detection; 270Hz, 330Hz, 1KHz, 2KHz. Display range -<br />

70~11dbm.<br />

Kingfisher Optical Attenuator<br />

KIN,KI7010 AU/MY<br />

1310/1550nm single-mode including 2 interchangeable pC connector<br />

interfaces, and adaptors. Attenuation range 60db, resolution 0.05, power<br />

capability +20dBm and linearity 0.02dB. Operational modes include manual,<br />

relative, step and programme control.<br />

Kingfisher KI 6000/8000 Optical Power Meter and Source<br />

KIN,KI6000/8000 AU<br />

Light source (KI8000) and power meter (KI6000) optical fibre test set for<br />

multimode applications 1300nm & 850nm. Units have ST connectors and<br />

a variety of patch leads. Light source modules 812 & 809 fitted to KI8000.<br />

KI6000 power meter uses a germanium detector for broadband operation.<br />

power meter can be used for single-mode applications but requires a<br />

seperate single-mode light source such as the KIN,KI8022.<br />

Nettest 6250/6025 Light Source/Power Meter 1310/1550<br />

GNE,6250/6025 AU<br />

Single-mode light source (6250) and power meter (6025) combination. Light<br />

source is 1310nm/1550nm, -8 dbm min power output laser output. power<br />

meter and light source autoswitch wavelengths to synchronize with each<br />

other. Stores past 2 results in memory for reference. Comes in hard case.<br />

Battery operated<br />

Nettest FI720 Active Fibre Detector<br />

GNE,FI720 AU<br />

Non intrusive fibre tool for identifying active fibres. Measures bare fibres,<br />

coated fibres, and jacketed patch cords. Gives readout of optical power level<br />

in fibre and can detect optical test tones of 270Hz, 1, & 2kHz. Measures<br />

wavelengths 800~1700nm and power levels from 0~-40dbm (±2). Insertion<br />

loss NEW<br />

Nettest CMA 5000 Singlemode 43/45dB OTDR<br />

GNE,CMA5000SM-45 AU<br />

Single mode OTDR with SC/ApC (angled) adaptor. 1310/1550/1625 dynamic<br />

range 43/45/43db. +20dbm meter and light source, and VFL (Visual Fault<br />

Locator). OTDR has built in CD-R/W and 20Gb hard drive. Dedicated touch<br />

screen and hard key user interfaces. Mains and battery operation, battery<br />

life >3h. 10/100Mb Ethernet port for network connectivity. USb ports.<br />

Nettest CMA4000 Single/Multi Mode OTDR<br />

GNE,CMA4000MMSM AU<br />

Includes mainframe and 850/1300nm (25/24db) multimode and 1310/1550nm<br />

(30/30db) single-mode module (module Model 4457). Instrument has built<br />

in FDD and supplied with SC/pC, FC/pC, and ST/pC connectors.<br />

Nettest CMA4000 Single/Multi mode OTDR<br />

GNE,CMA4000MM AU<br />

Single mode and multi mode OTDR. Includes mainframe and 850/1300<br />

nm (25/24 db) multimode and 1310/1550 (30/30 db) single mode module<br />

(module Model 4457). This instrument has built in 3.5 disc drive and is<br />

supplied with SC/pC, FC/pC, and ST/pC connectors.<br />

Nettest CMA4000 Single Mode OTDR<br />

GNE,CMA4000SM AU<br />

Includes mainframe and 1310/1550nm (34/36db) single-mode module<br />

(module part number TD-14M25003 Model 4425). Instrument has built in<br />

FDD and supplied with SC/pC, FC/pC, and ST/pC connectors.<br />

Nettest CMA4000 1310/1550nm (40dB) Single Mode Module<br />

GNE,TD-14M36003 AU<br />

For the GN Nettest CMA4000 OTDR mainframe. Module has SC/pC &<br />

FC/pC connectors. Operating wavelengths are 1,310nm (40db) & 1,550nm<br />

(40db).


NEW<br />

Yamasaki Y16 Fibre Cleaver<br />

YAM,Y16 AU<br />

Precision fibre cleaver. This cleaver can be used with precision splicers for<br />

single and multi mode fibres.<br />

> NEW<br />

Yamasaki Y80 Core Alignment Fusion Splicer<br />

YAM,Y80 AU<br />

Precision core alignment single and multi mode fusion splicer. Instrument<br />

is fully automatic or manual and provides a typical splice loss of 0.02 dB<br />

on single mode fibre, and 0.01 dB on multi mode fibre. The instrument has<br />

automatic environment sensors, operates from -10C to 50C, 95% humidity<br />

and operates up to 4000m. Includes a built-in heater for applying splice<br />

protectors and a splice tension tester. Front mounted colour display and can<br />

be operated from AC (176-264V, 47-63Hz), or battery.<br />

> NEW<br />

Fitel S325A Precision Fibre Cleaver<br />

FIT,S325A AU<br />

Can be used with precision splicers for single and multi mode fibres.<br />

Features a built in sharps collection bin which automatically stores fibre<br />

offcuts as each fibre is cleaved.<br />

> NEW<br />

Fitel S177A Core Alignment Fusion Splicer<br />

FIT,S177A AU<br />

Precision core alignment single and multi mode fusion splicer. Fully<br />

automatic and provides a typical splice loss of 0.02dB on single mode and<br />

0.01db on multi mode. Splice time 9sec. Temperature range -10~50ºC,<br />

humidity range up to 90% at 38ºC, and altitude sensors operate up to 4000m<br />

which adjust arc time and intensity as required. Includes a built-in heater for<br />

applying splice protectors and a splice tension tester (200g). Front mounted<br />

colour display. AC mains operation 100~240V, or battery (up to 70 splices).<br />

Excludes cleaver which must be rented separately.<br />

Fitel S323B Fibre Cleaver<br />

FIT,S323b AUNZ<br />

Use with precision splicers for single and multi mode fibres. built in sharps<br />

collection bin automatically stores fibre offcuts as each fibre is cleaved.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

fibre OpticS<br />

Fitel S121A V-Groove Fusion Splicer<br />

FIT,S121A AU<br />

Splice loss is 0.1dB for single mode & 0.05dB multi mode. Splice time is 13s.<br />

Includes splice protector heat shrink heater and splice tension tester (200g).<br />

Operates from ac (100~240V) or battery (up to 30 splices & heatings per<br />

charge). Cleaver excluded.<br />

Fitel S175 Core Alignment Single & Multi Mode Fusion Splicer<br />

FIT,S175 AU<br />

Default multi-mode operation is cladding align. Fully automatic. provides<br />

typical splice loss of 0.02db on single-mode & 0.01db on multi-mode.<br />

Temperature, humidity & altitude sensors adjust arc time & intensity. Includes<br />

built-in heater for applying splice protectors. Cleaver excluded.<br />

Fitel S176CF Core Alignment Single & Multi Mode Fusion<br />

Splicer<br />

FIT,S176 AU<br />

Fully automatic. Typical splice loss of 0.02db on single-mode & 0.01db on<br />

multi-mode. Splice time 13s. Temperature range -10~500C, humidity range<br />

up to 90%RH at 380C & altitude sensors (operates up to 3,658m) adjust arc<br />

time & intensity. Includes heater for applying splice protectors and splice<br />

tension tester (200g). Front mounted colour display. AC mains operation<br />

100~240V, or battery (up to 60 splices & heat shrinks per charge). Cleaver<br />

excluded.<br />

300M Multimode Fibre Optic Launch Cable<br />

FIb,MULTI/300M<br />

Multimode fibre test cable. 300 metres.<br />

Anritsu MG921A 1300nm Stabilised Light Source<br />

AU<br />

ANR,MG921A MY<br />

Use with multi-mode/single-mode fibre of 1.3µm wavelengths.<br />

Unprecedented light o/p level & wavelength stability through use of ApC<br />

& temperature control ccts. Internal & external modulation functions are<br />

provided, permitting removal of stray light.<br />

Nettest TD-4791-CL DWDM Optical Spectrum Analyser Module<br />

GNE,OSA-TD4791CL AU<br />

For dense wavelength division multiplexing applications. Can be used over<br />

optical fibre C (1,530nm~1,570nm) & L bands (1,570nm~1,628nm). Use<br />

with CMA-4000 mainframe. Resolution to 10GHz. For all WDM applications<br />

including high density of 80 channels and above.<br />

Nettest Nexus Polarisation Mode Dispersion Analyser<br />

GNE,pMD AU<br />

For optical C-band measurements. 55db dynamic range. For measurements<br />

on optical fibre for qualification for DWDM or analogue video applications.<br />

Noyes OFS300 Fibre Optic Cable Microscope<br />

NOT,OFS300 AU<br />

DATA, NETWORK & TELECOMMUNICATIONS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 35


CABLE/PIPE TESTERS & LOCATORS<br />

36<br />

cable/pipe teSterS & lOcatOrS<br />

> NEW<br />

Fluke IntelliTone Pro 200 Kit<br />

FLU,INTELLITONEpRO AU<br />

Locate, isolate, and validate twisted pair (UTp, Cat 5e, Cat 6), coax cables<br />

(RG6, RG59, and others for CATV/CCTV), bare wire (such as speaker wire<br />

and security network wire), and Cat 3 telephone cabling. The toner also lets<br />

you validate voice and data services.<br />

Tempo TE-508S Cable Locator<br />

TEM,508S AU/NZ<br />

Tempo 508S Cable Locator for locating buried or in-wall wiring. Compact<br />

design. Provides results on buried cables to depths of 1 meter and lengths<br />

up to 300 meters. Can be used to determine approximate depth of a wire or<br />

cable before you dig. Fully adjustable transmitter output and receiver gain<br />

Transmitter frequency is 447.5KHz. Transmitter can be connected directly to<br />

AC power outlet. Transmitter runs approximately 35 hrs and receiver runs<br />

approximately 20 hrs from standard 9V batteries.<br />

Pathfinder PF610 Circuit Tracer Kit<br />

pAT,pF610 AU<br />

For tracing concealed power cabling and other signal or data conductors.<br />

Comprises a transmitter and a detector. Transmitter when connected to a<br />

cable generates a 4.6kHz current pulse by drawing low current from the<br />

cable circuit. In the case of data and signal circuits a 9V battery can be used<br />

to power the cable. This may require disconnection of computer equipment,<br />

etc. Detector gives audible and visual indication of the signal field. Trace 1<br />

& 3 phase cables, coax, buried unpowered cable, locate fuses, etc.<br />

Pathfinder 220 Cable Locator/Tracer<br />

pAT,LOCAT220 AU<br />

For tracing live power cables within buildings. Connection is generally made<br />

at an outlet. Transmitter has visual and audible indication. Range 3m.<br />

Haganuk Teleflex 2000 Cable Fault Tester<br />

HAG,2000 AU<br />

Time domain reflectometer for power cables. Measuring ranges : 250, 500,<br />

1,000, 2,500, 5,000, 10,000, 25,000 & 50,000ft. pulse widths: 10, 100, 200,<br />

1,000, 2,000 & 10,000ns. Accuracy: ±1% typical,


Tektronix 1503C TDR Cable Tester<br />

TEK,1503C AU/NZ/MY<br />

Distance range 50,000’, resolution 0.04’ & 50, 75, 93, 125Ω output<br />

impedance. LCD display. Internal battery or mains operation. Supplied with<br />

ethernet testing and isolation network options.<br />

Tektronix 1503 Time Domain Reflectometer<br />

TEK,1503 MY<br />

Time Domain Reflectometer for long cable fault location. Display from<br />

0~5,000 to 0~50,000 feet. Internal battery or mains operation.<br />

Tasco P<strong>TR</strong>600 Cable Tracer<br />

TAS,p<strong>TR</strong>600 NZ<br />

Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2<br />

clamp CTs without disconnecting the earth conductor. Measures the dc loop<br />

resistance without any influence from other conductors.<br />

Radiodetection RD4000 Type 7 Cable Location Kit<br />

RAD,RD4000TYpE7KIT AU<br />

Includes transmitter and locator. Receiver has 640Hz, 8, 33 & 82kHz, 2<br />

power and radio modes. 3 locating modes. Modes, 2 peak, 1 null, location<br />

arrows, simultaneous digital depth and current readout. Transmitter T10<br />

version, FF, 640Hz, 8, 33 & 82kHz transmission freq. LCD display for freq,<br />

power, battery and connection readout, multimeter function, cable fault<br />

find function, 10W output, high efficiency induction mode. Signal clamp<br />

100mmØ. Connection leads and carry bag.<br />

Radiodetection A Frame for RAD,RD4000 Type 7 Kit<br />

RAD,AFRAME FORRD4000 AU<br />

A-Frame accessory for RAD,RD4000Type7KIT. For sheath to ground type<br />

fault finding.<br />

Radiodetection Flexisonde Pipe Tracer<br />

RAD,FLExISONDE AU<br />

Sonde for use with RD400pxL. Flexible rod on reel 50m long complete<br />

with 2 sondes. Small sonde transmitter is suitable for insertion into plastic<br />

pipes of 25mmØ & 150mm min bend radius. Can be detected at depths<br />

up to 1.5m. Larger sonde can be detected at 5m depth and is suitable for<br />

insertion into plastic pipes of 80mmØ & 210mm min bend radius. Sondes<br />

are battery operated.<br />

Radiodetection Supersonde<br />

RAD,SUpERSONDE AU<br />

Can be connected to the RAD,FLExISONDE cable if required. Detectable<br />

to 15m depth.<br />

Radiodetection 100mm Clamp Antenna<br />

RAD,CLAMp-ANT AU<br />

For use with RAD,RD400pxL. Identify an individual cable out of a bunch.<br />

Good for cable tracing. Transmitter is connected to one end and placed<br />

around individual cables for identification. Clamp is 100mmØ.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

cable/pipe teSterS & lOcatOrS<br />

Radiodetection RD400PXL Pipe and Cable Locator<br />

RAD,RD400pxL AU<br />

Can measure current in buried lines. Includes transmitter and locator, peak<br />

and null location by audio and meter, very useful in congested areas. Has<br />

power /radio/8kHz/33kHz modes, can read depth to 3m. Includes direct<br />

connect lead and signal clamp (tong) (10cm). Works with optional sondes to<br />

trace sewers and plastic pipes.<br />

> NEW<br />

CScope CATXDSGV-KIT Cable and Pipe Locator<br />

CSC,CATxDSGV-KIT AU/NZ<br />

Cable location tool. Includes 33kHz generator with touch button controls<br />

and LCD, xD receiver/ locator with 33kHz, power or radio modes. Direct<br />

connection cable, stake and 75mm tong set. The transmitter can operate<br />

with direct connection, tongs or induction. The instrument will also determine<br />

cable depth, range 0.2m to 3m . It will operate with the Radiodetection<br />

33kHz sondes.<br />

ICC LD400 Ultrasound Leak and Emission Detector<br />

ICC,LD400 AU<br />

Used to detect water and gas leaks, from ultrasonic emission. Also used for<br />

mechanical noise location. Supplied complete with an ultrasonic transmitter<br />

to enable leaks within containers to be detected, e.g. vehicle bodies, fuel<br />

tanks. Aural and visual indication. battery operated.<br />

ICC LD408 Noise Leak Detector<br />

ICC,LD408 MY<br />

Used to detect water & gas leaks, etc. from ultrasonic emission. Also may<br />

be used for mechanical noise location. Supplied complete with an ultrasonic<br />

transmitter to enable leaks within containers to be detected, e.g. vehicle<br />

bodies, fuel tanks. Aural & visual indication. battery operated.<br />

Ultra Probe UP100KT Ultrasonic Leakage Detector<br />

ULT,Up100KT AU/NZ<br />

Hand held pistol type with stainless steel sensor enclosure. Frequency<br />

reponse 20~100kHz, (centred at 28 ~42kHz), 10 segment LED bargraph<br />

(red). Sensitivity 8 precision attenuation. Response time 300ms, operating<br />

temperature range 0~500C. Kit includes contact stethoscope module with<br />

different wave guide extension rods for direct for use on pipes, bearing<br />

housings, steam traps, etc. Rubber focusing probes, head set, warble tone<br />

generator for determining leaks in seals of empty containers, etc.<br />

Primayer Omikron Water Leak Detector<br />

pRI,OMIKRON-AG AU<br />

Water leak locating listening probe and ground microphone system designed<br />

to locate leaks in water pipe. Supplied with headphones and interconnection<br />

cables. probe detects leak noise directly at available valves hydrants, etc.<br />

High sensitivity and wide band amplification of leak noise particularly at lower<br />

frequencies. Microphone will detect noise reaching the ground surface.<br />

CABLE/PIPE TESTERS & LOCATORS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 37


ELEC<strong>TR</strong>ICAL POWER


ELEC<strong>TR</strong>ICAL POWER<br />

40<br />

magnetic field meterS - gauSS teSla<br />

Model Type Frequency (Hz) Range (G) Electric Field Output<br />

ARL,GM AC magnetic field meter 12~1,300 9.9 ~ 99mG CRO<br />

HOL,HI-3627 Vector AC magnetic field meter 5~2,000 0.2 ~ 20<br />

HOL, HI-3604 AC field strength meter 50~100 0.1 ~ 20,000mG 1~200,000V/meter<br />

TES,70 AC magnetic field meter 30~600 0.1 ~ 1,999mG<br />

HMI,GM04<br />

bEL,4080 Digital gauss meter<br />

40~600 0.1mG ~ 511mG<br />

> NEW<br />

Bell 5180 Gauss/Tesla Meter<br />

bEL,5180 AU<br />

Magnetic measuring equipment, portable gaussmeter. built-in software<br />

eliminates the need for complex calibration procedures. Key features<br />

include Auto Zero, Min./Max./peak Hold, Auto Range and Relative Mode.<br />

Allows the user to select Gauss, Tesla or Ampere/Meter readings. With<br />

Hall effect transverse probe. Frequency bandwidth DC~30kHz, range up to<br />

30kG. Analogue output (±3V FS) and USb interface. battery operated.<br />

Arlyuna LF Milligauss Magnetic Field Strength Meter<br />

ARL,GM NZ<br />

Handheld ac magnetic field strength meter. Ranges 9.9mG & 99mG.<br />

Measurement bandwidth 12Hz~1.3KHz. 60Hz & 50Hz filter and analogue<br />

ac output for connection to oscilloscopes, recorders or loggers.<br />

Bell 4048 ac/dc Gauss Meter<br />

bEL,4048 NZ<br />

Handheld digital ac/dc Gauss/Tesla meter. Ranges are 200~20kGauss with<br />

a resolution of 0.1Gauss or 0.02~2Tesla with a resolution of 10E-6Tesla.<br />

Accuracy is 2% +2 digits. peak hold feature. Supplied with transverse probe<br />

and zero gauss chamber.<br />

Bell 4080 ELF Gaussmeter<br />

bEL,4080 AU<br />

Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging<br />

0.1~511mG. probe: 3 axis technology, maintains accuracy regardless of<br />

orientation. True rms measurement. Typical accuracy error: ±2%, +1 digit.<br />

Frequency response: ±5% 40~600Hz, -3db 25/1,000Hz. Applications<br />

include detecting magnetic field emissions from overhead ac power lines,<br />

video display terminals, office equipment and household appliances. This<br />

unit is not suitable for measuring field strength of “neodymium” or “rare earth”<br />

magnets or any permanent magnets. The frequency response ± 5% 40-<br />

600Hz and -3db 25/1000Hz.<br />

Bell 5080 Gauss/Tesla Meter<br />

bEL,5080 AU<br />

Portable gaussmeter complete with Hall effect transverse probe. Frequency<br />

bandwidth dc - 20kHz, ranges 300G~30kG. Max resolution 0.1G (10µT). Max<br />

and min hold. Analogue output and RS232 interface. battery operated.<br />

dc~10kHz 30 ~ 30,000<br />

bEL,4048 dc~12 200 ~ 20,000<br />

BEL,5080 dc~20kHz 300 ~ 30,000 Analog & RS232<br />

BEL,5180 dc~20kHz 300 ~ 30,000 Analog & USb port<br />

bEL,4090-20 Digital ELF gauss meter 40~400 0.1 ~ 1999mG<br />

Holaday HI-3627 Magnetic Field Meter<br />

HOL,HI-3627 AU<br />

Three orthogonal field sensors. Dynamic range 0.2mG~20G. True rms<br />

detection. Frequency range 5Hz~2kHz with an in-built 30Hz high pass filter.<br />

Meets requirements of the Swedish protocol and the IEEE p-1140 protocol.<br />

Holaday HI-3604 LF E & H Field Monitor<br />

HOL,HI-3604 AU/MY<br />

Low frequency field meter. Designed to evaluate electric and magnetic fields<br />

associated with 50Hz power lines. Frequency range 30~2,000Hz. Measures<br />

magnetic fields from 0.1 milligauss to 20 gauss. Measures electric fields from<br />

1 volt/meter to 200 kilovolts/meter. LCD display. 127 reading data memory.<br />

Meets the interim requirements of the Australian Radiation Laboratory for<br />

normal levels of AC power exposure.<br />

Hirst GM04 Microprocessor Controlled Gaussmeter<br />

HMI,GM04 AU<br />

Facilities: store and recall on 0~99 samples, hold. Analogue peak with<br />

digital storage. Auto and manual ranges. Automatic reading conversion<br />

between different units. (Note 1mT = 10G)<br />

Range 1: 0~to more than 3T resolution 1mT.<br />

Range 2: 0~299.9mT resolution 100µT.<br />

Range 3: 0~29.99mT resolution 10µT.<br />

Range 4: 0~2.999mT resolution 2µT.<br />

Accuracy (at 200C): ± 1%. Frequency range: dc and 15Hz~10kHz.<br />

Functions: dc, dc peak, ac rms, ac rms max, & ac peak. Applications include<br />

measurement of magnetic flux density of magnets and assemblies, electric<br />

motor air gaps and drive actuators.<br />

Hirst Magnetic Instruments GM04 Axial Probe<br />

HMI,GMO4AxIAL pRObE AU<br />

Axial probe for use with HMI,GM04.<br />

Teslatronics 70 milliGauss Meter<br />

TES,70 NZ<br />

Tri-axial ac magnetic field meter. Range is 0.1~1,999mGauss, accuracy is<br />

±1% at 60Hz. Frequency response is 40~400Hz ±10%, 50~300Hz ±5%,<br />

30~600Hz - 3db.<br />

Tri-axial Milligauss Magnetic Field Meter<br />

bEL,4090-20 NZ<br />

Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging,<br />

0.1~1999mG. Resolution 0.1mG in high-sensitivity mode & 1mG resolution<br />

in low-sensitivity mode. probe 3 axis technology, maintains accuracy<br />

regardless of orientation. True rms measurement. Typical accuracy error:<br />

±1% + 1 digit. Frequency response: ±10% 40~400Hz, -3db, 20/2000Hz.<br />

Applications include detecting magnetic field emissions from overhead<br />

ac power lines, video display terminals, office equipment and household<br />

appliances.


Model Type<br />

SEW,x3760pKIT+<br />

SEW,EUROpA pAT<br />

portable Appliance Tester<br />

Voltage<br />

V<br />

Resistance<br />

Ω<br />

Current<br />

A<br />

MEG,CBT2 RCD Tester 6~500mA<br />

MEG,LT6 Earth Loop Impedance 20~2kΩ<br />

Frequency<br />

Hz<br />

Features<br />

AS3760:2001 Compliant, full<br />

keyboard, barcode scanner,<br />

RS232, Automatic label/tag<br />

printer<br />

AS3760:2001 Compliant, barcode<br />

scanner, RS232<br />

LEM,SATURN GEO<br />

EASY<br />

0~20kΩ 50mA 128 Battery,RS232<br />

LEM,SATURN GEO x<br />

Soil Resistivity Tester<br />

48ac<br />

1mΩ~300kΩ 250mA 94~128<br />

battery, Stakeless measurement,<br />

earth loop impedance,RS232<br />

MEG,DET5/3R 0.1~19,999 128 Battery<br />

MEG,DET20C Earth Resistance Clamp 25mΩ~1550Ω 0.2~35 battery, USb output of data<br />

MEG,BM21<br />

MEG,BM11D<br />

25~5000 5TΩ 2mA/kV<br />

500,1kV, 2.5kV,<br />

5kV<br />

10kΩ~500GΩ<br />

MEG,10-01-10KV 10kV 1TΩ 99µA<br />

MEG,1020-10KV DIT<br />

Insulation Tester<br />

50~5000 35TΩ<br />

dc<br />

Operates from main supply or<br />

battery<br />

LEM,SATURNISO 50 ~ 1,000 30GΩ Battery<br />

HIO,3455HVIT,5KV<br />

250, 500, 1kV,<br />

2.5kV, 5kVdc<br />

5TΩ 1mA<br />

HIO,3454-51-3 250, 500, 1000 4GΩ 200mA<br />

HVD,HVA30-DC/VLF High Voltage Insulation<br />

DielectricsTest Set<br />

33kV, 5µF 190hm 15mA<br />

HVD,HVA60-DC/VLF 60kV, 50mA<br />

CHK,LM05<br />

1µΩ~20Ω 10<br />

dc/VLF<br />

Battery<br />

Operates from main supply or<br />

rechargeable battery<br />

battery, data storage & USb<br />

interface<br />

Insulation with 200mA continuity<br />

tester<br />

Four in one HV test set<br />

VLF/DC/Jacket Sheath/Fault<br />

Conditioning<br />

CRO,D07 600µΩ~60Ω 10 c/w probe/Lead Set<br />

T&R,DSM600 67µΩ~6.6mΩ 600<br />

T&R,DSM200 200µΩ~4Ω 200/10<br />

VAL,4300b<br />

Micro-Ohm Meter<br />

2µΩ~20kΩ 100mA~10<br />

dc<br />

Heavy duty Kelvin leads<br />

MEG,DLRO10<br />

MEG,DLRO1-10x<br />

0.1mΩ~2kΩ 10<br />

Alpha-numeric keypad for<br />

entering test notes, autoranging<br />

with manual option, realtime or<br />

MEG,DLRO200<br />

0.1µΩ~999.9mΩ<br />

10~200<br />

from storage via RS232, large<br />

backlit LCD<br />

MEG,DLRO600 10~600 RS232, Software<br />

MEG,CM500<br />

0~250mA 16~460 RS232, Software, RCD tester,<br />

MEG,MFT1502<br />

Multifunction Installation<br />

Tester<br />

280~1kV<br />

0.01~499MΩ<br />

0~200mA 45~65<br />

Loop impedance, Prospective<br />

short circuit<br />

LEM,SATURN100+ 1~400 0.01~9.99kΩ 0~1 15.3~457 Battery<br />

bAU,DpA75<br />

0~ 75kV rms RS232<br />

Oil Insulation Tester<br />

AVO,OTS60pb 60kV rms Battery, RS232<br />

bJM,ALL-TEST3 Motor, Coil Tester 1 kV 0~20MΩ 100~2,400 Power Factor, Capacitance<br />

3M,701 Megohm Meter 10 ~ 100 0~10GΩ ESD Surface Testing<br />

MEG,MIT1020-10KV DIT Insulation Resistance 1kV~10kV 10kΩ~35TΩ USb, RS232, battery<br />

MEG,RCDT330 Residual Current Device 0~300 10mA~1kmA 25~450 USb, battery, Ip54<br />

See Also Hi-pot Testers<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Battery<br />

RS232<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 41


ELEC<strong>TR</strong>ICAL POWER<br />

42<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

> NEW Megger MIT1020 Diagnostic 10kV Insulation<br />

Resistance Tester<br />

MEG,MIT1020-10KV DIT AU<br />

backlit display, variable test voltage from 50~5000V, Automatic IR, pI, DAR,<br />

SV and DD tests, measures to 35TΩ, RS232 & USb download of results.<br />

IEEE 43-2000 recommends the use of 10kV for motor windings rated above<br />

12kV. protection rating of Ip54. Mains or battery powered.<br />

Megger 10-01 10kV Insulation Tester, Test Voltage 500~10,000V<br />

MEG,10-01-10KV AU<br />

The Megger MEG,10-01-10kV Insulation Tester is a compact, Microprocessor<br />

controlled high voltage dc Insulation tester.<br />

> NEW HV Diagnostics 30kV-15mA DC/VLF High Voltage<br />

Insulation DielectricsTest Set<br />

HVD,HVA30-DC/VLF AU/NZ<br />

VLF (0.1Hz), DC (±), cable fault conditioning (burning), and sheath/jacket<br />

testing modes all included. 0.1Hz & 0.02Hz. For solid dielectric cables<br />

such as xLpE and EpR. Fully automatic or manual cable test sequences<br />

complying with International Standards/Guides such as IEEE 400.2, VDE<br />

0296, CENELEC, etc. True symmetrical sinusoidal, load independent,<br />

output waveform across the full load range. Real-time display of actual<br />

output waveform. Easy to use, menu guided, large backlit user interface.<br />

Large output load capability (up to 5µF). Automatic and integrated load<br />

capacitance measurement with optimum frequency selection. Storage of test<br />

results for later retrieval or download to laptop. Short circuited protected.<br />

> NEW HV Diagnostics 60kV-50mA DC/VLF High Voltage<br />

Insulation Dielectrics Test Set<br />

HVD,HVA60-DC/VLF AU<br />

True sine wave low frequency output. 0.1Hz & 0.02HZ. For VLF, DC and<br />

jacket/sheath testing. Fault conditioning capability. Test result storage<br />

capability. Short circuit protection. Complies with CENELEC, IEEE 400.2,<br />

VDE 0296 and other international standards. Manual or fully automatic test<br />

sequence selection. Real-time display of actual output waveform. High<br />

voltage power source suitable for testing electrical plant including cables:<br />

xLpE, pE, EpR, pILC etc, capacitors, switchgear, transformers, rotating<br />

machines, insulators and bushings.<br />

Hioki 3455 High Voltage Insulation Tester<br />

HIO,3455HVIT-5KV AU<br />

pI and DAR function to check insulation quality and step voltage test to detect<br />

for signs of deterioration. Generates a wide range of test voltages, from<br />

250V to 5kV. The voltage may be chosen from the commonly used presets<br />

of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or<br />

decrements of 25V or 100V. Insulation diagnoses for automatic calculation<br />

and indication of pI (polarisation index) and DAR (Dielectric absorption ratio),<br />

step voltage testing and temperature correction. Large memory stores up to<br />

100 manual records and a logging function for 10 data (360 times). Stored<br />

data may be displayed on the LCD or down-loaded to a pC. The date and<br />

time of measurement also recorded.<br />

CHK LM05 Micro-Ohm Meter 10A<br />

CHK,LM05 AU/MY<br />

Operates from internal batteries or external power supply. Max test current<br />

10A. Resistance range up to 20Ω with a max sensitivity of 1µΩ. Includes<br />

power supply-charger, duplex helical test leads, length 2m.<br />

Megger DLRO10 Micro-Ohm Meter<br />

MEG,DLRO10 AU<br />

Self contained automatic micro-ohm meter, selecting the most suitable test<br />

current, up to 10A dc to measure resistance from 0.1mΩ~2kΩ on one of<br />

seven ranges. Instrument is built into a strong, lightweight case that is<br />

equally at home in the field or in the laboratory. Light enough to be worn<br />

around the neck, small enough to be taken into areas which were previously<br />

too small to access. DLRO10 uses a large, bright 4½ digit LED display.<br />

Resolution: 0.1µΩ. battery: rechargeable NiMH, typical life 1,000 test at<br />

full load.


Hioki Digital MΩ HiTester Insulation Tester<br />

HIO,3454-51-3 AU<br />

Continuity function with 200mA and 3 range voltage selectable 250V, 500V<br />

& 1kV. Easy to read digital display, auto-discharge, live-wire warning, safety<br />

system for high voltage measurement, sliding cover. back-lighting liquid<br />

crystal display for easy reading in dark areas, checks ground wire continuity<br />

with a short circuit current of 200mA. Capable of testing the continuity of<br />

electrical facility grounds in accordance with IEC 60364. Measurement<br />

range insulation resistance maximum 4000MΩ @ 1kV. Other functions:-<br />

insulation and low resistance mode - comparator, measurement value hod,<br />

insulation resistance mode - auto discharge, insulation and ac voltage mode -<br />

live wire warning (when voltage of 70V+ or -10V exists across measurement<br />

terminals). Low resistance mode - zero adjust. All measurement modes -<br />

battery indicators, auto power off. Maximum rated working voltage 600Vac.<br />

RCD Isolation Test Transformer for Testing Portable RCD Unit<br />

pRO,ITx125VA-RCD AU<br />

RCD Isolation Test Transformer for Testing portable RCD units. Input 240V<br />

50Hz and output 230V 125VA thermally protected isolation transformer.<br />

This is only suitable for testing portable RCDs and by using this isolation<br />

transformer will avoid tripping of the whole circuit. It comes with 15Amps<br />

Australian / New Zealand Socket. Isolation test transformer can be used to<br />

test up to 150mA trip current<br />

Cropico DO7 Micro-Ohm Meter complete with Probe/lead Set<br />

CRO,DO7 AU<br />

Low resistance measurement for use in workshop, field or test facilities.<br />

Rugged construction, in a sealed plastic case with lid and carry handle.<br />

Advanced features including protection up to 415V rms at the measuring<br />

terminals, digital calibration and long scale length, 6,000 count. Rechargeable<br />

batteries >1h of continuous operation on lowest ranges, & 20h on all others.<br />

Battery charge indicators are provided. Internal charger will boost charge<br />

to 90% of full charge, switching automatically to a maintenance charge.<br />

Warning LEDs illuminate when an open circuit lead condition is detected.<br />

RS-232 output for connection to an external printer or pC. plug is provided<br />

for the connection of external start switch, eg. foot switch. Supplied with<br />

batteries, mains cord and test leads. For special lead sets we offer a variety<br />

of different styles, together with calibration standards.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Megger DLRO-10X Digital Low Resistance Ohmmeter<br />

MEG,DLRO-10x AU/NZ<br />

Automatically selects the most suitable test current, (up to 10Adc) to<br />

measure resistance from 0.1µΩ~2kΩ on 1 of 7 ranges. Real-time download<br />

of results and on-board storage for later download to a pC. Automatically<br />

detects continuity in potential and current connections. Visible warning of<br />

high voltages present at the terminals. Visible warning of current flowing in<br />

the test sample. Multiple operating modes including fully automatic. Alphanumeric<br />

keypad for entering test notes. User selectable high and low limits.<br />

Autoranging with manual option.<br />

Megger DLRO600 Digital Micro-Ohm Meter- High current<br />

MEG,DLRO600 AU<br />

Measures resistance between 0.1µΩ & 1Ω at high currents. provides<br />

test currents from 10A~600A subject to the load resistance and supply<br />

voltage. backlit liquid crystal display shows information needed to perform<br />

a test; all test parameters and measurement results are displayed. Range:<br />

0.1µΩ~999.9mW [subject to supply voltage and load resistance]. Accuracy:<br />

voltage ±0.5%, ±0.1mV, current ±0.5%, ±0.1A. Resistance: better than<br />

µΩ~100mW. power supply for full output: 207~265V 50/60Hz with a load<br />

less than 7mΩ including current leads [i.e. standard 5m 50mm² current leads<br />

only, 4mΩ load]. Reduced output: down to 100V 50/60Hz. Test current<br />

range 10A~600A unsmoothed dc in 1A steps, accuracy ±2%, ±2A. Test<br />

Modes manual, auto, continuous. Test Time 7s NORMAL /AUTO mode.<br />

Refreshed every 2s in CONTINUOUS mode. Voltmeter input impedance<br />

>200kW. Data Transfer real time or batch download via RS232 using AVO<br />

Download Manager. Storage Capacity 300 result sets and memo, battery<br />

backed for 10y.<br />

Megger 200A Micro-Ohm DLRO200<br />

MEG,DLRO200 AU<br />

Digital low resistance micro-ohm meter 200A.<br />

T&R DSM200 200A Micro-Ohm Meter<br />

T&R,DSM200 AU<br />

Max 200A. Max resolution 0.1µΩ. Digital display with RS232 output. AC<br />

mains operation. Complete with 3m leads.<br />

T&R DSM200 600A Micro-Ohm Meter<br />

T&R,DSM600 AU<br />

Max output 600A max resolution 0.1µΩ. Digital display with RS232 output.<br />

AC mains operation. Complete with 3m leads.<br />

Valhalla 4300B Digital Micro-Ohm Meter<br />

VAL,4300b AU<br />

Selectable current ranges 100µA~10A. Suitable for large electrical<br />

machinery. Resistance ranges 2mΩ~20KΩ with a max resolution of 0.1µΩ.<br />

basic accuracy 0.03% with a 4½ digit display. Supplied with heavy duty<br />

Kelvin leads.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 43


Megger BM21 500V/1/2/5kV Insulation Test Set<br />

MEG,bM21 AU<br />

Test voltages 25~5,000V in 25V steps. Insulation range to 1TΩ at 500V,<br />

5TΩ at 5kV. AC/dc voltage measurement 50V~1kV. Leakage current<br />

measurement. Capacitance measurement at end of test. Automatic<br />

discharge of capacitance. In-built test timer. Insulation burn mode - short<br />

circuit current 1mA nominal. battery life 8h, in-built charger for charging<br />

from mains or 12V dc.<br />

AVO/Megger BM11D Analogue/Digital 5kV Insulation Tester<br />

MEG,bM11D AU/MY<br />

Test voltages 500V, 1kV, 2.5kV and 5kV. Insulation range 10kΩ~500GΩ<br />

digital. AC/dc voltage measurement 50V~1kV. Timer 0~60min. Automatic<br />

discharge of capacitance. battery life 8h, in-built charger for charging from<br />

mains or 12V dc.<br />

Megger BM25 Insulation Tester<br />

MEG,bM25 AU/NZ<br />

Five kV insulation tester which is battery-powered, housed in a rugged case<br />

and has a large, analogue/digital LCD. A built-in timer makes both spot<br />

tests and polarisation Index (pI) testing easier to carry out. pre-set standard<br />

test voltages at 500V, 1, 2.5 & 5kV with variable test voltage in 25V steps.<br />

Displays capacitance at the end of a test to 10µF. Performs automatic PI,<br />

Step Voltage and Dielectric Discharge tests as well as providing an optically<br />

isolated RS232 port for downloading results during a test. Short circuit<br />

current: nominal 1.8mA, max 2mA. battery life: typically 8h.<br />

Megger CM500 Multifunction Installation Tester<br />

MEG,CM500 AU/NZ<br />

Combines the function of several instruments. Non-tripping loop test for<br />

tests on RCD protected circuits. RCD ramp test features actual tripping<br />

current. Functions are insulation, continuity, loop testing, RCD tests, voltage<br />

& frequency measurement. Phase indication, outlet polarity indication.<br />

Stores approximately 750 test results in memory for uploading to PC.<br />

> NEW<br />

Megger RCDT330 Residual Current Device Tester<br />

MEG,RCDT330 AU<br />

Tests standard, dc, selection and programmable RCDs. Ramp testing. Auto<br />

(remote) testing. 3ph safe. Enables testing on 110V centre tapped supplied.<br />

performs 1/21, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA,<br />

300mA, 500mA & 1000mA on general and selective (time delayed) RCDs.<br />

Tough rubber armoured case with built-in cover. Weatherproof to Ip54. USb<br />

interface for downloading test result.<br />

LEM Saturn Insulation Tester<br />

LEM,SATURNISO AU<br />

Test voltages 50~1,000V in steps of 10V. Max range 30GΩ. Measures<br />

ac/dc voltage to 600V, resistance to 30kΩ. Digital and analogue display.<br />

Battery operated.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Megger CBT2 Earth Leakage Breaker Tester<br />

MEG,CbT2 AU<br />

Residual current device (RCD)/safety switch, circuit breaker tester. Twelve<br />

ranges from 6~500mA. Displays tripping time in ms.<br />

Metrel MI 2121 AUS Advanced RCD Tester<br />

MET,MI2121AUS AU<br />

Exceeds all requirements of AS/NZS3760:2003. Stores up to 500 tests.<br />

Interface RS232 Software.<br />

Megger BT51 Low Resistance Ohmmeter<br />

MEG,bT51 AU<br />

Uses 4 terminal method with helical duplex dual pronged probes. Test<br />

current 2A nominal at 2Ω. Ranges 2, resolution 1mΩ, 20mΩ, resolution<br />

10µΩ. Accuracy at 0~500C, ±1% of reading, ±2digits. Display LED 3½<br />

digit. Power supply internal NiCd rechargeable batteries, typically around<br />

2,000 tests at 5s duration. Re-charge time around 10h with 240Vac mains<br />

power. Nett weight 45kgs.<br />

Megger LT6 Digital Loop Tester<br />

MEG,LT6 AU<br />

Earth fault loop impedance tester 20Ω range 0.01Ω resolution, 2kΩ range<br />

1Ω resolution. Single & 3ph systems can be tested. Used with MEG,CbT2<br />

to test compliance to AS2381.1 (electrical wiring for hazardous areas).<br />

Tests automatically when connection to circuit is made. Neons indicate fault<br />

conditions.<br />

Megger MFT1502 Combined Insulation, Loop & RCD Tester<br />

MEG,MFT1502 AU<br />

Tests fixed wiring in accordance with International and National Wiring<br />

Standards. Display digital/analogue arc LCD. Voltage measurement<br />

automatic selection ac or dc up to 270V. Continuity testing 200mA from<br />

0.01~99.9Ω, automatic continuity testing commences the moment the test<br />

probes touch the circuit to be tested. Audible tone to confirm test. Safety<br />

check for presence of a voltage. Variable buzzer threshold selectable from<br />

2~100Ω in 6 steps. Insulation testing 250, 500V & 1kV. Safety lockout<br />

at voltages greater than 55V. Auto discharge facility safely discharges all<br />

circuits after insulation test. Low current loop test, a 3-wire non-tripping<br />

0.01Ω loop test designed to prevent RCD tripping. High current loop test<br />

at 25A provides a fast test where no RCD is fitted. Supply voltage and<br />

polarity indication at 55V~280V, 45Hz~65Hz phase to phase. phase~phase,<br />

phase~neutral and phase~earth loop tests are possible. Loop measurements<br />

from 55V~480V. prospective short~circuit current (pSC), a high current loop<br />

test, is provided for rapid measurement of loop currents, both at the socket<br />

outlet and distribution board. Ranges from 1A~19.9kA with a resolution of 1,<br />

10 & 100A depending on range auto-ranging. RCD testing 10mA~1000mA<br />

with both 0 & 180O phase angle. RCD ramp test measures the RCD trip<br />

current. Displays actual trip current on all RCD ranges instead of trip time.<br />

LED torch in illuminated probe for low light level areas. Ip54<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 45


ELEC<strong>TR</strong>ICAL POWER<br />

46<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

Kikisui TOS-5051 5kV ac/dc Hi-Pot Tester<br />

KIK,TOS-5051 AU<br />

High voltage ac/dc insulation test set. Ranges 0~2.5kV & 0~5kV. Max<br />

output ac 100mA, dc 10mA. pass/fail comparator included.<br />

> NEW<br />

Megger Digital Earth Test Clamp<br />

MEG,DET20C AU<br />

Measures ground resistance from 25mΩ~1550Ω . Measures ground<br />

leakage current from 0.2mA~35A. Automatic self calibration. Auto ranging.<br />

High and low alarms. Large memory. Download to Megger Download<br />

Manager. Measures earth resistance in installations such as buildings,<br />

pylons and RF transmitter sites. Use for the inspection and verification of<br />

lightning protection systems. Large jaw opening.<br />

Megger Det5/3R Ground Resistance Tester<br />

MEG,DET5/3R AU<br />

MEG,DET5 NZ<br />

Checks resistance of electrical systems including soil resistivity. Measures<br />

resistance from 0.01~19,999Ω in 4 ranges. LCD 3½ digit display. Operating<br />

frequency 128Hz. Complete with earth testing kit including spikes and wire.<br />

3M Model 701 Micro-ohm ESD Surface Tester<br />

3M,701 AU<br />

Tester for static control surfaces, table mats, field service kits, floor coverings,<br />

etc. Test voltages 10 & 100V. Resistance range 0~100GΩ.<br />

Baur DAP75 Insulating Oil Tester<br />

bAU,DpA75 AU<br />

Output voltage 0~75kV rms. Selectable programmes to international<br />

standards. Integral printer. RS232 interface.<br />

AVO OTS60PB Transformer Oil Tester<br />

AVO,OTS60pb AU<br />

Test voltage 60kV max at 61.8Hz. Fully automatic operation. Rechargeable<br />

battery operation. RS232C interface.<br />

BJM All-Test III Motor, Coil and Winding Tester<br />

bJM,ALL-TEST3 AU<br />

Tester for single or polyphase ac motors, generators, transformers or<br />

dc motors. Use to test any motor, coil or winding to determine insulation<br />

condition between windings, windings and frame, open circuits. Also<br />

measure phase balance and angle. Impedance (z) 5~1,000Ω. Inductance<br />

(L) 0.35mH~1.6H. Capacitance (C) 100mF~50nF. power factor (Fi) 0~90O .<br />

Insulation 0~20MΩ @ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz<br />

(times 2).<br />

BJM All-Test IV PRO 2000<br />

bJM,ALL-TEST-4 AU<br />

Tests single or polyphase ac motors, generators, transformers or dc motors.<br />

Use to test any motor, coil or winding to determine insulation condition<br />

between windings, windings and frame, open circuits. Measure phase<br />

balance and angle. Impedance (z) 5Ω~1kΩ. Inductance (L) 0.35mH~1.6H.<br />

Capacitance (C) 100mF~50nF. power factor (Fi) 0-90 O . Insulation: 0~20MΩ<br />

@ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz (times 2).<br />

LEM Saturn GEO Easy Earth Tester<br />

LEM,SATURN GEO EASY AU<br />

Waterproof instrument (rubber protective cover IP56). Measures earth<br />

resistance, 3 or 4 pole. Soil resistivity. Measures resistance from 0~20kΩ.<br />

Display 4 digit back light 25mm LCD. Operating frequency 128Hz. Single<br />

button user interface. Complete with earth testing kit including 4 stakes, 3<br />

reeled cables, clips and carry case.<br />

LEM Saturn GEO X Earth/Soil Resistance Tester<br />

LEM,SATURN-GEO-x AU<br />

Automatically tests earth/soil resistance 3, 4 pole and stakeless with CT.<br />

Optimise output frequency (manual or automatic) 0.001~300kΩ at 20 &<br />

48Vac, frequency 94, 205, 111, & 128Hz. Displays all measuring results<br />

for as long as desired. programmable limits. Optical and audible over-limit<br />

warning. Splash-proof case Ip56 (outdoor application). Measurements with<br />

current clamps: selective, stakeless. Resistance measurements with 250mA<br />

short circuit current. Output of measured values via interface on printer or<br />

PC.<br />

LEM Saturn 100plus Safety Tester<br />

LEM,SATURN100+ AU<br />

Confirms correct operation of RCD protection, resistance of all aspects of<br />

protective earthing systems, loop impedance, line-neutral polarity, predictive<br />

short circuit current, phase sequence and voltage. RCD current 10mA~1A.<br />

Tripping time 1~500ms. Tripping current measurement with intelligent ramp.<br />

Fault voltage 0.1~99.9V. Loop and earthing resistance 0.15W~10kW. Earth<br />

electrode voltage (SEV 3569) up to 199V. Short-circuit current 1A~9.99kA.<br />

Loop/line internal resistance RLOOp 0.07~200W. Nominal line voltages<br />

100~435V. battery-saving, automatic switch-off, typical battery service-life<br />

3,500 insulation measurements.<br />

Multi-amp MET-2 Clamp-On Earth Tester<br />

MUL,MET-2 NZ<br />

Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2<br />

clamp CTs without disconnecting the earth conductor. Measures dc loop<br />

resistance without any influence from other conductors.<br />

Seaward Europa Advanced Portable Appliance Tester<br />

SEW,EUROpA pAT AU<br />

Records results, compliant with AS/NZS 3760: 2001/2003 can be printed as a<br />

certificate using the serial/parallel adaptor. bar-code reader included. Earth<br />

continuity output current 100mA~25A ac. Range 0.01~20Ω. Accuracy ±5%<br />

of reading ±2 digit. Insulation test range, 100kΩ~100MΩ. Test voltage,<br />

250, 500Vdc. Resolution 0.01MΩ. Includes plug adaptor to test, EpODs<br />

and extension leads (IEC - IEC and Australian).


Seaward PAT Management Software (WIN)<br />

SEW,pATGUARD-SW-WIN AU<br />

Seaward’s pATGuard plus takes a significant leap in electrical safety<br />

management software. Its unique “Drag and Drop” presentation makes<br />

the software intuitive and very easy to use. pATGuard both uploads and<br />

downloads appliance information and test results from the Europa xE,<br />

Europa plus and Supernova xE. Users have a complete visual overview<br />

of all appliances in terms of locations and test status. Appliances are<br />

simply dragged and dropped from one location to another. Repeat testing<br />

requirements are easily displayed allowing scheduling of tests to be<br />

conveniently managed and uploaded into the appliance tester<br />

Trolley Suitable for SEW,XE3760PKIT+ SUPERNOVA PAT Tester<br />

SEW,<strong>TR</strong>OLLEY-3760pKIT<br />

This trolley is specially designed for SEW,xE3760pKIT+ and very useful for<br />

portable Appliance Tester, Seaward xE 3760 pKIT+. This trolley comes with<br />

the following accessory and contains four layer shelving, extension board<br />

with five socket 240V / 10 Amps, extension cable approximately 25 meters,<br />

2 Nos. of elastic tie rope and a plastic bin. By using this trolley one can fit all<br />

the required instruments for portable Appliance Testing and this will improve<br />

performance and higher productivity.<br />

Seaward PAC 3760 Appliance Checker<br />

SEW,pAC3760 AU<br />

performs the following tests in conformance to AS/NZS 3760:2000, earth<br />

bond, insulation & polarity tests, also leakage current tests for Class I &<br />

Class II appliances and leads (leakage current testing of appliances, which<br />

requires power to “switch” them on, is the method required by AS/NZS3760:<br />

2003). Features simple pass/fail indication. Unique 3 button operation.<br />

Class I, class II and leakage current. Automatic test sequence senses<br />

an IEC or extension lead then performs a polarity test. Detects that the<br />

appliance under test is switched “On”. Earth bond test is set at 10A and is<br />

capable of fusing a poor earth. Large LCD.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Seaward Supernova XE3760+ PAT System with Printer and<br />

Scanner<br />

SEW,xE3760pKIT+ AU<br />

SEW,xE3760pKIT NZ<br />

Includes results label/tag printer and barcode scanner. performs all AS/<br />

NZS3760: 2001/2003 compliant tests, including class 1 & class 2 leakage<br />

current 5mA/1mA, an earth conductor bond test up to 25A at 3V (approx.<br />

100W) and 250Vdc MOV insulation resistance tests. Stores 5,000 tests<br />

in internal memory by appliance ID, including test type, detailed results,<br />

test time & date, next test due date, site & location. Calibrated resolution<br />

better than the required 5% of full scale across all ranges as specified by<br />

the Standard. Full QWERTY keyboard, and bar code reader for input.<br />

Durable plastic adhesive test label/tags printed to attach to appliances and<br />

leads includes user ID (logo optional on request) and test barcode ID, saves<br />

transcription. Compatible with Seaward pATGuard plus software package.<br />

PRO-TAG Thermal Transfer Printer<br />

pRO,TAG-pRINTER AU<br />

print durable and permanent synthetic test tags on-site directly from your<br />

Europa xE, Europa plus or Supernova xE appliance safety testers. Easy<br />

- test the appliance, print the tag, peel it off and stick it on. Accountable - the<br />

pro-Tag systems are fool proof and tamper evident. Test tags are generated<br />

direct from the tester’s test results. Fast & Cheap - no more hand writing<br />

test tags and pro-Tag test tags are less than half the price of vinyl tags.<br />

Accurate - tags are printed with appliance number, appliance bar code, test<br />

date, user name and test status from the tester’s memory. Customise - you<br />

can personalise the test tag with your own company logo.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 47


ELEC<strong>TR</strong>ICAL POWER<br />

48<br />

pOWer analySerS & recOrderS<br />

Model Type<br />

VOL,pM3000A<br />

VOL,VpAS<br />

LEM,TOpAS1000<br />

LEM,MEMObOx 300<br />

DRA-bMI,px5<br />

DRA-bMI,px5-400<br />

DRA-bMI,pG4400<br />

REL,1600<br />

HIO,3196-pQA<br />

power quality/<br />

demand<br />

Software<br />

power quality/<br />

demand<br />

Network<br />

performance<br />

analyser<br />

Universal power<br />

quality/demand<br />

Universal power<br />

quality/demand<br />

Universal power<br />

quality/demand<br />

Volt<br />

Inputs<br />

Current<br />

Inputs<br />

3 3<br />

4 4<br />

3 4<br />

4 4<br />

Current (A)<br />

(Max,rms)<br />

30 A direct<br />

1 kA/3kA CT<br />

3kA<br />

3 kA/6 kA<br />

3 kA/6 kA<br />

3 kA/6 kA<br />

5 5 1 kA<br />

5 kA<br />

Features Output<br />

400 Hz, Harmonics 99th<br />

Very high accuracy<br />

NATA certified unit available<br />

Sampling 10MHz<br />

Harmonics 50th<br />

Interharmonics 5~2,500Hz<br />

(in steps of 0.5Hz)<br />

Sampling 1Mhz transient<br />

Harmonics 63rd<br />

Flicker, pst, plt<br />

Sampling 1Mhz transient<br />

Harmonics 63rd<br />

Flicker, pst, plt<br />

Sample rate 256/cycles<br />

Harmonics 63rd<br />

Flicker, pst, plt<br />

Sampling 4MHz<br />

Harmonics 63rd<br />

Sampling 2 MHz<br />

Harmonics 50th<br />

Display, RS232,<br />

+ more<br />

RS232,Ethernet, software<br />

RS232 serial cable<br />

CODAM plus software<br />

128Mb, compact flashcard<br />

128Mb, compact flashcard<br />

128Mb, compact flashcard<br />

Parallel, software<br />

Display, ethernet, RS232,<br />

Compact flash card<br />

HIO,3197pQA 5 kA Harmonics 50th Display, USb<br />

power quality/<br />

CHK,PM20 demand<br />

3 4<br />

1 kA/3 kA Sampling 11.4kHz, THD Display, RS232, software<br />

CHK,PM30 1 kA/3 kA<br />

Sampling 11.4kHz,<br />

Harmonics 48th, Ip56<br />

Display, RS232, Software<br />

RS232 POWERview<br />

CHK, PM30 Plus<br />

3 kA<br />

THD and individual to 48th harmonics<br />

Flexible Cts/Clamp Cts<br />

software,<br />

4Mb memory<br />

CHK,pM40pQA RS232, USb, 15Mb Memory<br />

DRA-bMI,pR150<br />

150 A Universal current clamp ac/dc<br />

CT<br />

DRA-bMI,pR1500 1500 A Universal current clamp ac/dc<br />

DRA-bMI,pR6035A/36 Flexible CT 6000A ac Flexible CT, 36” length<br />

DRA-bMI,<strong>TR</strong>2021<br />

CHK,CR100 100<br />

CT<br />

CHK,CR500 500<br />

1-30A Instrument CT, 48Hz – 10kHz<br />

DRA,<strong>TR</strong>2510 10A ac Instrument CT, 1-10A<br />

CHK,CRT1000L 1 Ka<br />

CHK,CT3000L 1<br />

CHK,CK1 3ph current<br />

1<br />

CHK,CK5 converter<br />

5<br />

MEG,pA9 pLUS<br />

Portable power<br />

analyser<br />

4 5 6 kA<br />

ALG,UpM6001 Power demand 3 3+aux 20 A/1 kA<br />

ALG,UpM6100<br />

power quality/<br />

demand<br />

4 4<br />

20 A direct<br />

3 kA<br />

ALG,RET Flexible CT 3 kA<br />

ALG,C173<br />

Precision CT for<br />

earth leakage<br />

1 mA~1 kA<br />

Up to 63rd harmonics & THD<br />

Sample rate 256/cycle<br />

Current voltage simultaneously<br />

600~6,000 flexible CTs<br />

Harmonics 25th<br />

For 4th current channel of UpM<br />

Harmonics 50th, 14~500Hz<br />

12Mb internal memory<br />

256Mb compact flash card<br />

Display, printer, RS232,<br />

software


Model Type<br />

HIO,2331-20RpMS<br />

HIO,2332-2RpMS<br />

YEW,CW140<br />

Power demand<br />

Volt<br />

Inputs<br />

Current<br />

Inputs<br />

AVO, pENTA-pLUS-DMM 3ph DMM/demand 3<br />

BMI,8800<br />

bMI,A-111 Voltage plug-in<br />

bMI,A112<br />

bMI,A116<br />

Power Quality 4 4 CTs<br />

CT<br />

Current (A)<br />

(Max,rms)<br />

Features Output<br />

4 440 0~500 A Remote power measurement Ethernet<br />

3<br />

500 A~<br />

700 A<br />

100 direct/<br />

3 kA CT<br />

600<br />

400Hz, Harmonics 13th<br />

ac/dc, voltage phase angle<br />

400Hz, Harmonics 30th,<br />

Sampling 2MHz<br />

Display, FDD, RS232,<br />

optional printer<br />

Display, RS232,<br />

Parallel printer<br />

Chart, FDD, RS232,<br />

Viewing software<br />

bMI,A120<br />

3 kA<br />

DRA,808 Power demand 3 3CTs Chart<br />

DRA,<strong>TR</strong>2015 CT 3 kA<br />

DRA,635-G5 Termination 5 A<br />

DRA,646-3<br />

DRA,626<br />

Power Quality<br />

4 Chart<br />

DRA,pA6030-1 Graphics print out<br />

3<br />

DRA,pA6024A Harmonics 7th<br />

MET,pF-1-F Current logger 69kV RS232, software<br />

MET,Mx2040 1ph power demand<br />

2 kA Display, analogue out<br />

1CT<br />

MET,Mx200 Clamp on Ammeter 1<br />

200 A Display<br />

LEM,ANALYST-2060 1 ph Power Demand 1 2 kA Harmonics 25th Display,RS232, IR, software<br />

HIO,8710<br />

DRA,CAF-RS232<br />

DRA,CAF-ETHERNET<br />

Voltage/Current<br />

Recorder<br />

Communication<br />

adaptor<br />

Communication<br />

adaptor<br />

Chart<br />

3 3 1500 3 channel recorder, voltage or current Chart<br />

Fibre to RS232 with Node link software<br />

Fibre to Ethernet with Node link<br />

software<br />

DRA,128MbFMC Flashcard Ultra high speed0<br />

DRA,DVMDS Math Driver Software<br />

pRO,MAGNUS-2.2KV Step Up Transformer 1 1<br />

Rescue kit for any corrections – logged<br />

data<br />

Prepare excitation curves for instrument<br />

transformer, demagnetize CT and<br />

conduct trun ratio test on VT<br />

ACR,pOWERWATCH Disturbance Logger 1 Voltage disturbance recorder<br />

HAW,5000 Power demand 3 3 1000 Energy monitoring<br />

DRANETZ ac/dc Current Clamp 3 - 150A<br />

DRA,pR150 AU<br />

AC/dc current clamp/probe 3 - 150A RMS, max conductor size is 52mmØ.<br />

Current clamp/probe is suitable for any of new Dranetz-bMI models DRAbMI,pG4400,<br />

DRA-bMI,px5, DRA-bMI,px5-400. Current clamp/probe is<br />

very useful for current measurement through CT current transformer. CT<br />

Ratio can be selected on the new Dranetz-bMI above-mentioned models.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

pOWer analySerS & recOrderS<br />

RS232<br />

Dranetz ac/dc Current Clamp 3 - 1500A RMS<br />

DRA,pR1500 AU/NZ<br />

Max conductor size is 52mmØ. Current clamp is suitable for any of new<br />

Dranetz-bMI models DRA-bMI,pG4400, DRA-bMI,px5, DRA-bMI,px5-<br />

400. Current clamp/probe is very useful for current measurement through<br />

CT current transformer. CT Ratio can be selected on the new Dranetz-bMI<br />

above-mentioned models.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 49


ELEC<strong>TR</strong>ICAL POWER<br />

50<br />

pOWer analySerS & recOrderS<br />

Dranetz-BMI Power Xplorer PX5<br />

DRA,px5 AU/NZ<br />

provides the full range of measurements include V, I, W, VA, VAR, TpF, DpF,<br />

Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum<br />

(V, I, W) to the 63rd, Flicker (pst, plt), Crest factor, K factor, transformer derating<br />

etc. Min/Max/Avg values are determined in ½ cycle RMS steps. Asset<br />

comes with ac flexible current clamp DRA-bMI,RR3035A/24, current range<br />

30/300/3,000A ac only. Can be extended to different ranges of measurement<br />

both ac & dc by selecting appropriate current clamps. High-speed transient<br />

capture (1MHz sampling rate) and the full range of arithmetic, vector and<br />

sequence parameters to evaluate distorted and un-balanced loads as<br />

defined in IEEE 1459. Exceeding high/low limits of any active parameter<br />

can trigger logging. Voltage & current disturbances can be triggered by<br />

peak value, wave-shape change & cycle-by-cycle RMS value change. preevent<br />

& post-event waveform capture cycles are user adjustable. Voltage<br />

& current channels can be cross-triggered. Suitable for both ac/dc power<br />

quality measurements. (Universal power Quality Analysers). DRA-bMI,px5<br />

analysers can be used for power quality measurements, current inrush<br />

(cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage<br />

logging), long term monitoring and continuous logging at 1s intervals. Four<br />

differential voltages and current channels can be used independently. DRAbMI,px5<br />

is Class A compliant with IEC Standard 61000-4-30 ‘power Quality<br />

Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic &<br />

Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data<br />

is collected at 256 samples/cycle/channel.<br />

Dranetz-BMI Power Xplorer PX5-400Hz<br />

DRA,px5-400 AU<br />

Specificaion as above but with 400Hz capability suitable for aviation and<br />

military use.<br />

Dranetz Current Clamp 1 - 30A 48Hz~10kHz<br />

DRA,<strong>TR</strong>2021 AU<br />

Set of 3 current clamps 1~30A RMS, 48Hz~10kHz. Max conductor size<br />

0.47”. Description as for DRA,pR6035A/36 current clamps above.<br />

Dranetz-BMI Power Guide 4400<br />

DRA,pG4400 AU/NZ<br />

provides the full range of measurements include V, I, W, VA, VAR, TpF, DpF,<br />

demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum<br />

(V, I, W) to the 63rd, flicker (pst, plt), crest factor, K factor, transformer<br />

de-rating etc. Min/max/avg values are determined in ½ cycle RMS steps.<br />

Asset comes with ac flexible current clamp DRA-bMI,RR3035A/24, current<br />

range:- 30/300/3,000A ac only. Can be extended to different ranges of<br />

measurement ac/dc by selecting appropriate current clamps. Has the full<br />

range of arithmetic, vector and sequence parameters to evaluate distorted<br />

and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits<br />

of any active parameter can trigger logging. Voltage & current disturbances<br />

can be triggered by peak value, wave-shape change & cycle-by-cycle RMS<br />

value change. pre-event & post-event waveform capture cycles are user<br />

adjustable. Voltage & current channels can be cross-triggered. Suitable for<br />

both ac/dc power quality measurements.(Universal power Quality Analysers).<br />

DRA-bMI,pG4400 analysers can be used for power quality measurements,<br />

current inrush (cycle-by-cycle current logging), fault recording (cycle-bycycle<br />

voltage logging), long term monitoring and continuous logging at 1s<br />

intervals. Four differential voltages and current channels can also be used<br />

independently. DRA-bMI,pG4400 is Class A compliant with IEC Standard<br />

61000-4-30 ‘power Quality Measurement Methods’ (also AS DR04066),<br />

AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-<br />

15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.<br />

Dranetz Flexible Current Clamp 60/600/6,000A<br />

DRA,pR6035A/36 AU<br />

Set of 3 flexible current clamps 60/600/6,000A RMS, max conductor<br />

size/length of clamp is 36”. Current clamps are suitable for any of new<br />

Dranetz-bMI Models. DRA-bMI,pG4400 / DRA-bMI,px5 / DRA-bMI,px5-<br />

400. Current clamp/probe is very useful for current measurement through<br />

CT current transformer. CT Ratio can be selected on the new Dranetz-bMI<br />

above-mentioned models.<br />

Dranetz Current Clamp Probe 0~10A RMS<br />

DRA-bMI,<strong>TR</strong>2510 AU<br />

Set of 3 current clamps 0~10A RMS. Max conductor size 0.47”. Description<br />

as for DRA,pR6035A/36 current clamps above.<br />

Dranetz-BMI, 128 MB Flash Memory Card (Industrial Grade)<br />

DRA,128MbFMC AU/NZ<br />

Suitable for the following Dranetz -bMI Models:- DRA-bMI,px5, DRAbMI,px5-400,<br />

DRA-bMI,pG4400.


Dranetz Communications Adapter - Fibre to Ethernet with Node<br />

Link SW<br />

DRA-bMI,CAF-ETHERNET AU<br />

Communications Adapter - Fibre to Ethernet with NodeLink Software and<br />

Moxa Networking Software for the following Dranetz-bMI Models:- DRAbMI,px5,<br />

DRA-bMI,px5-400, DRA-bMI,pG4400.<br />

Dranetz View Math Driver Software (Add ON)<br />

DRA-bMI,DVMDS AU<br />

In 4 essential areas, the Math package will improve measurements:-<br />

Rescue Kit. Ever hooked up a probe the wrong way? May be forgotten to<br />

check if the actual time in your instrument is running correctly? Or could you<br />

have possibly forgotten to set the correct K-factors? The Math -package<br />

helps you to correct these errors, re-calculate parameters from available<br />

waveform data, invert waveforms and much more. Improve Measurements<br />

/ Reports. Calculate additional parameters for your Multi-DAQ TASK<br />

Card, fault-recorder/inrush mode measurements, with the math driver the<br />

following additional trends will be created for Multi-DAQ data files: V rms,<br />

Watts, VAR’s, VA, True pF, V thd (%fundamental), I thd (abs current) Voltage<br />

Frequency (for internal trigg) and Net Totals V rms, Amps, W, VAR & VA.<br />

Generate More parameters from waveform data. Showing Displacement<br />

power Factor (DpF) instead of K-factor. Rename inputs. Energy ON/OFF<br />

peak calculations. Mathematical expressions and formulas can be used<br />

to plot additional user-defined channels within both the time-plot chart<br />

and the waveform chart. Advance analysis, watt harmonics, symmetrical<br />

components, etc.<br />

Dranetz 646-3 Disturbance Recorder<br />

DRA,646-3 AU<br />

Accepts up to 3 ac line inputs 50~600V, 1 neutral to ground input 5~200V,<br />

& 1 dc voltage input 1~100V. Monitors and records impulses, sags, surges,<br />

under and over voltages and frequency variations on 1~3ph ac, 47~63Hz.<br />

Impulse duration 1~1,000µs.<br />

Dranetz 626 Power Disturbance Monitor<br />

DRA,626 AU<br />

For use with up to 5 x pA series plug-ins. Monitors sags, surges, impulses<br />

and changes in frequency.<br />

ACR Voltage Disturbance Logger<br />

ACR,pOWERWATCH NZ<br />

Single phase 230V disturbance logger. Plugs into a standard 230V 3pin<br />

power point. Stores up to 4000 events such as sags, surges, outages,<br />

impulses & frequency variations. Supplied with software & serial cable for<br />

programing, uploading and printing results.<br />

BMI 8800 Power Disturbance Analyser<br />

bMI,8800 AU<br />

Eight inputs giving simultaneous voltage and current (optional probes<br />

required) monitoring of up to 4 channels each. FDD included. Each<br />

disc stores 600 disturbances for transfer to the internal graphics printer.<br />

Harmonics measurement option included for up to the 40th harmonic of<br />

50Hz. Max input voltage 600V rms or dc. Eight extra channels included for<br />

sensor outputs, etc. Operates from ac mains or 11~16Vdc. In-built UpS.<br />

BMI A-111 ac/dc Voltage Impulse Probe<br />

bMI,A-111 AU<br />

For bMI,4800/8800. Uses probe channels to increase the number of voltage<br />

inputs that can be monitored. Ranges 0~600V rms, 0~100V dc. Impulses<br />

0V~2.4kV peak.<br />

BMI A112 Current Probe for BMI 8800<br />

bMI,A112 AU<br />

For bMI,4800/8800. Measures current waveforms to 600A and allows<br />

graphic representation on bMI,4800 printout. Jaw opening 50mm. True<br />

rms measurements for motor startup, current surges, etc. Range can be<br />

extended to 3kA by using DRA,<strong>TR</strong>2015 in secondary loop configuration.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

pOWer analySerS & recOrderS<br />

BMI A116 600 Amp Clamp-on Probe for 8800<br />

bMI,A116 AU<br />

Aperture 50mmØ. bandwidth 3kHz.<br />

BMI A120 3000 A Clamp-on Probe for 8800<br />

bMI,A120 AU<br />

Aperture 63 x 160mm. bandwidth 3kHz.<br />

Metrosonics PF-1-F Overhead Profiler<br />

MET,pF-1-F AU<br />

Distribution line profilers for current measurement on power lines. Logs<br />

current consumption to internal memory. Set of 3 profilers with one display<br />

module. Windows software included. Current range 5~1000A. Resolution<br />

1A. Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate<br />

1s~10min. Memory 64k readings. Data storage modes: stop when full or<br />

wrap around. Data retention after low battery shutdown 30d. Min conductor<br />

spacing 600mm.<br />

> NEW Hioki Remote Power Measurement System 2331-20<br />

RPMS SmartSite<br />

HIO,2331-20RpMS AU<br />

For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3 wire &<br />

3ph 3 wire up to 3 circuits. Provides via a PC, management of measurement<br />

data to support energy and environmental management. Modulated<br />

measurement units take advantage of a variety of infrastructure to collect<br />

measurement data. Use as a stand alone logger and for remote monitoring.<br />

Use as a pC measurement logger keeps measuring and continuously saves<br />

the data. Measurement modules comes with memory and clock. build a<br />

customised and remote measuring system by utilizing existing data network.<br />

Modules for temperature, humidity, instrumentation and pulse, power module<br />

for multiple circuits. Large internal memory. Communication module with<br />

built-in real-time clock tracks the data of each measurement module to the<br />

second. Air Module for constructing SS wireless systems.<br />

> NEW Hioki Remote Power Measurement System 2332-20<br />

RPMS SmartSite<br />

HIO,2332-20RpMS AU<br />

Description as for HIO,2331-20RpMS above.<br />

Hawk 5000 3 Phase Power Demand Logger<br />

HAW,5000 NZ<br />

Three phase wye power demand logger. Records kVA, kW, V, I, Freq & pF.<br />

Uploads data to a pC for graphing and printing. Supplied with software and<br />

3 x 1kA clamps.<br />

Dranetz 808 Power Demand Analyser<br />

DRA,808 AU<br />

Displays and prints on in-built printer - V, A, pF, kW, kWh, kV/A, kVAR,<br />

demand, time and date for single and three phase systems. For use with<br />

DRA,635-G5 terminations or <strong>TR</strong> series clamp-on current transformers.<br />

Dranetz <strong>TR</strong>2015 Clamp-on Current Transformer<br />

DRA,<strong>TR</strong>2015 AU/NZ<br />

For DRA,808. Ranges 1, 2 & 3kA. Requires DRA,635-G5 termination.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 51


Voltech PM3000A 3 Phase Power Analyser<br />

VOL,pM3000A AU<br />

Capable of making measurements of all standard electrical characteristics<br />

of 1 & 3 phase supplies. Measures inrush current and crest factor, load<br />

impedance and harmonic analysis, energy and max demand, extendable<br />

using current and potential transformers. Frequency range dc~500kHz.<br />

parameters W, VA, Var, V, A, pF, peak voltage and current, crest factor,<br />

impedance, peak inrush current, voltage and current harmonics, 99th order,<br />

THD, Hz, Wh, VAh, Varh, Amph, average pf. Input coupling may be ac or ac<br />

+ dc. Outputs printer, recorders (8), and oscilloscopes. IEEE, RS232C, and<br />

centronics interfaces and waveform output derived from current and voltage<br />

inputs are included. Accuracy V & A 0.05%, power 0.1%. Input ranges<br />

voltage 0.5V~1kV rms, current 0.05~30A rms (200A peak). Accessories<br />

3 x 1kA clamp-on CTs, and 3 x precision 100A/1kA dual range current<br />

transformers 0.2% (not clamp on).<br />

Voltech PM3000A with NATA Calibration<br />

VOL,pM3000A-NATA AU<br />

Specifications as above but with NATA calibration.<br />

LEM Analyst 2060 Hand-held 1 Phase Clamp-on Power Meter<br />

Analyser<br />

LEM,ANALYST-2060 AU<br />

Measure, record and log W, VA, VAR, kWh, and power factor. Current to<br />

2kA auto-ranging ac or dc. peak, Crest Factor, THD, DF and frequency for<br />

voltage (4~750V) and current. Harmonics to the 25th order. Time base is<br />

selectable from 2ms/div~50ms/div. Large backlit multi parameter display,<br />

with oscilloscope and chart modes. Memory size: 8 screens smart save and<br />

up to 10,000 readings. Jaw opening capacity 60mmØ. Typical battery (6 x<br />

AA alkaline) life 24h without backlight.<br />

LEM Topas 1000 Power Network Analyser<br />

LEM,TOpAS1000 AU<br />

Measures all relevant parameters in one measurement system. Inputs<br />

(isolated) voltage 4 channels, 200mV~1kV, current 4 channels, supplied<br />

with 4 x 0~10A, 10~100A ac clamp-on CTs and 4 x (unit powered) 0~3kA<br />

LEM-Flex current sensors. Can be configured for 8 voltage channels.<br />

Measuring functions rms, V(U) voltage imbalance, positive, negative & zero<br />

phase sequence, phasor (vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz),<br />

energy, on-line oscilloscope, power and multimeter, harmonics (by power/<br />

direction, magnitude & phase), inter-harmonics, THD, flicker, transients<br />

(100kHz~10MHz), will capture events from 0.1µs in duration. Software<br />

configured manual or auto trigger levels, ethernet or serial interface, memory<br />

>540Mb/HDD.<br />

LEM Memobox 300 Network Performance Analyser<br />

LEM,MEMObOx300 AU<br />

Weatherproof (Ip65)3ph power analyzer. High accuracy to Class A IEC<br />

61000-4-30. Suitable for 50Hz or 60Hz systems. LEMflex flexible current<br />

probes with ranges 15, 150, 1,500 & 3,000A suitable for conductors up<br />

to 178mmØ. Voltage ranges from 115~830V on 3 or 4-wire systems.<br />

Measures V, A, kW, kVA, kVAR, kWHr, pF, Hz, crest factor, distortion power,<br />

THD, individual harmonics of volts & current up to 50th harmonic, flicker and<br />

ripple control signal levels. Power measurements by either 2 or 3 wattmeter<br />

method. power supply 88~415V either from measurement leads or separate<br />

supply. Memory size 4Mb with 5,700 sampling intervals. Sampling intervals<br />

selectable from 1s~60min. Sample interval of 5min records for >19Days.<br />

Linear or circular (overwrites earliest data once full) memory. Records<br />

average, 10ms min & 10ms max in each interval. Captures motor start<br />

current spikes with corresponding voltage-dips. Captures up to 13,000<br />

voltage sag/surge events 10ms or longer. Weight 1.1kg.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

pOWer analySerS & recOrderS<br />

LEM Elmes 693 3Ph Power Logger<br />

LEM,603 NZ<br />

Logs, voltage, current & pF. True RMS: VA, VAr, pF, Volts, A & frequency.<br />

Sampling rate is 1s. Statistical measurement interval can be set from<br />

1~60min. Supplied with flexible 1kA Rodowski CTs, 5A clip-on CTs and<br />

software for programming and uploading results. Accuracy, active power<br />

±2%, reactive power ±3%, phase angle ±3%, voltage ±1.5%.<br />

Reliable Power Systems 1600 Analyser<br />

REL,1600 AU<br />

Power analyser for parameter, demand, and disturbance measurement<br />

and long term monitoring. pC required for download - no onboard display.<br />

Complete with 1kA CT’s & 5A CT’s. V & I sampled at 8kHz, min/max values<br />

have 1 cycle response. Impulses sampled at 2 & 4MHz software selectable.<br />

Max input voltage 700V rms. Notebook pC with Win 95 and Office 97<br />

included.<br />

Algodue UPM6001 Power/Demand Analyser<br />

ALG,UpM6001 AU<br />

Includes 3 x 1kA clip-on current transformers. Integral digital display and<br />

printer. Memory 512kb plus RS232 interface for data transfer. Measures<br />

each phase & total V, A, power, pF, VA, VAR. Measures demand over a<br />

defined interval, harmonic distortion, and provides FFT analysis. Records<br />

maxima and minima. Current inputs are at 1V or 5A for external CT’s.<br />

Voltage drop detection for durations exceeding 150ms. Software provides<br />

time plots and remote display of measurement parameters. Higher speed<br />

FFT harmonic plot possible up to 25th harmonic.<br />

Algodue UPM6100 Uni Power Meter 500Hz & Rogowsky 3kA<br />

Options<br />

ALG,UpM6100 AU<br />

power meter 3kA Rogowski current transducer (flexible CTs), 14~500Hz,<br />

harmonic distortion current and voltage 50th order. Large 4Mb memory.<br />

Algodue Ret Set of 3 Rogowski Transducer<br />

ALG,RET<br />

Use with the ALG,UpM6001. Ranges 300A/3kA. powered from analyser.<br />

> NEW Hioki 3197 Power Quality Analyser with 3x1000A<br />

Clamp-on CTs<br />

HIO,3197pQA AU<br />

Monitors inrush current, voltage swell, voltage dips, transient over-voltage<br />

and interruptions. Measure and records power and power factor, active/<br />

reactive energy, demand, load changes (with graph display), voltage and<br />

current. Measures impulsive voltage quality. RMS voltage quality, voltage<br />

swell, voltage dips & voltage interruption. Power quality, frequency, voltage,<br />

current, current peak, active/reactive/apparent power & power factor<br />

(displaced power factor). Three phase quality, voltage unbalance ratio,<br />

current unbalance ratio, harmonic quality (up to 50th order). Harmonic,<br />

voltage, current, ower, voltage/current phase angle. Total harmonic, voltage<br />

distortion, current distortion (THD-F, THD-R).<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 53


ELEC<strong>TR</strong>ICAL POWER<br />

54<br />

pOWer analySerS & recOrderS<br />

> NEW Hioki 3169-20 Clamp-On Power HiTester for Power<br />

Measurements<br />

HIO,3169-20CLAMpONpT AU<br />

Allows measurement of 1ph~3ph 4-wire circuits with a single unit. In<br />

addition to measuring standard parameters such as voltage, current, power,<br />

power factor, and integrated values, this unit can simultaneously perform<br />

demand measurements required for carrying out power management and<br />

energy-saving measures, as well as harmonic measurements. Features<br />

PC card data storage and comes equipped with an RS232C interface for<br />

PC communications. Can measure the power of just a few cycles, enabling<br />

more detailed and effective energy-saving measures. Supplied with Hioki<br />

9625 power measurement support software for data analysis. Measure up<br />

to 3ph, 3 wire system (displays voltage and current for 3 lines), up to 4 x<br />

1ph, 2 wire systems, 5A~5kA range, pC card data storage, power recording<br />

for individual waveforms. Simultaneous recording of demand values and<br />

harmonics. Applications are energy maintenance/control, energy control<br />

under ISO 14000, saving energy activities, power consumption measurement<br />

of specific device/equipment, harmonic analysis.<br />

> NEW<br />

HIOKI 3169-21 Clamp-On Power HiTester<br />

HIO,3169-21 CLAMpONpT AU<br />

Measure up to 3-phase, 3-wire system (displays voltage and current for<br />

three lines), Measure up to four single-phase, 2-wire systems, 5A~5000A<br />

range. Compact and light weight, PC card data storage, power recording<br />

for individual waveforms, simultaneous recording of demand values and<br />

harmonics. Main applications: energy maintenance/control, energy Control<br />

Under ISO 14000, saving energy activities, power consumption Measurement<br />

of specific device/equipment and harmonic analysis. Complete with RS232C<br />

interface for pC communications. Supplied with Hioki 9625 power<br />

Measurement Support Software for data analysis.<br />

Hioki 3196 3 Phase Power Quality Analyser<br />

HIO,3196-pQA AU<br />

High speed (0.5µs 2MHz) field unit. Channels 4 voltage, 150~600V rms 4<br />

ranges (isolated), 4 current 0~5kA (3ph and neutral) rms 2 ranges. Supplied<br />

with 4 x 5kA flexible clamp-on CTs (length 945mm). Memory 13Mb internal,<br />

512Mb compact flash card. Display internal high resolution colour LCD.<br />

Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 50th<br />

order) flicker IEC6100-4-15. Total energy, tariffs, max demands, transient<br />

and sub-cycle disturbances. Software provides graphs and summaries to<br />

PC. Interfaces RS232 and 10base ethernet.<br />

> NEW<br />

Hioki 9670 Thermal Printing Method Printer, Input RS232C<br />

HIO,9670 pRINTER AU<br />

Uses stationary type, thermal printing method printer which prints date input<br />

via RS232C from a computer or the other host system. Convenient battery<br />

that makes easy to carry around. provides high-speed printing with very<br />

little noise. provides clear printing of 16 x 16 dots and 24 x 24 dots (as<br />

well as Japanese characters JIS Level I and II), and can print bar codes.<br />

provides various settings such as enlarged-character printing. Graphics can<br />

be printed using bit images.<br />

Hioki 9694 Clamp-on CT 5A<br />

HIO,9694CT5A AU<br />

Rated primary current 5A ac. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at<br />

45~66Hz), 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated<br />

wire. Core jaw 15mmØ. Size: 46w × 21d × 135hmm, cord length 3m.<br />

Hioki Clamp-on 100A ac CT<br />

HIO,9660CT100A AU<br />

Rated primary current 100A ac. Amplitude accuracy: ±0.5% rdg. ±0.2%fs (at<br />

45~66Hz). 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated<br />

wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.<br />

Fluke 43 Power Quality Analyser<br />

FLU,43 NZ<br />

Single phase power quality analyzer. Combination power quality analyzer,<br />

multimeter and scope. Scope displays voltage and current waveforms.<br />

Measures true-rms voltage, current and frequency. Measures voltage,<br />

current, and power harmonics up to 51st harmonic. Total harmonic distortion<br />

(THD). Phase angle of individual harmonics. Continuously measure volts<br />

and amps on a cycle-by-cycle basis for up to 24h. Use cursors to read time<br />

and date of sags and swells. Supplied with 500A current probe, software<br />

and cable.<br />

Fluke 43B 1 Phase Power Quality Analyser<br />

FLU,43b NZ<br />

Combines the capabilities of a power quality analyser, scope and multimeter<br />

in a single easy-to-use instrument. EN 61010-1 CAT II, 600V. UL and CSA<br />

listed. Recording times 4min~16d (selectable).<br />

Megger PA9Plus Portable Power Quality & Demand Analyser<br />

MEG,pA9pLUS AU<br />

Integral graphic backlit LCD and compact flash card memory. Measures<br />

and records all voltage/current power and waveform activity. Input voltage,<br />

4 differential channels auto ranging between 20~300, 300~600V ac, V dc<br />

scales, accuracy ±0.25% of reading, ±0.05% of range to the 63rd harmonic.<br />

Crest factor voltage 3.5 limited to 1.5kV peak. Current 1.4 of full scale at<br />

peak input. Current 5 channels resolution 0.1% fs, accuracy ±0.25% of<br />

reading, ±0.05% of range to the 63rd harmonic. Frequency fundamental<br />

50Hz response dc to 3.15kHz (63rd harmonic). Resolution 0.01Hz. Sample<br />

rate 256/cycle current and voltage simultaneously. Harmonic distortion<br />

current and voltage to the 63rd order and THD. power supply 90~600Vac,<br />

50Hz, 100~600Vdc either via channel 1 or from independent IEC lead.<br />

Memory 12Mb internal, 512Mb compact flash card. Current sensors 4 x<br />

600~6,000A Rogowski flexible. Report generation software included. Setup<br />

and download can be done through RS232 or flash card.<br />

> NEW CCI Power-Mate 15A Single Phase Power/Energy<br />

Measurements<br />

CCI,pOWER-MATE 15A AU<br />

Can accurately measure and calculate power, volts, amps and energy being<br />

used by an electrical appliance. Also measures the greenhouse gas emission<br />

created by an appliance. Can determine the actual running cost, how much<br />

energy the appliance used in kilowatt-hours and how many kilograms of<br />

greenhouse gas emissions it produced all in hourly, yearly, quarterly and<br />

accumulated figures. Features an LED display for easy reading and high<br />

visibility at all times. 15-amp version - to a maximum continuous capacity of<br />

15A, but readings are accurate to 18A and the cable is rated to 15A. provides<br />

a variety of measurements including: power in watts, voltage and current.<br />

Provides the minimum, maximum as well as instantaneous readings.


NEW<br />

CHK Gridsense PM40 Power Quality Analyser<br />

CHK,pM40pQA<br />

Weatherproof Ip65 field unit. Channels: 3V, 63-440V (isolated). 4 current<br />

0 to 3,000A (3ph and neutral) rms. Supplied with 4 flexible 3,000A clampon<br />

CTs (flexible CT length 600mm and Diameter 190mm). (In addition,<br />

clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A<br />

for neutral conductor current measurement are available.) Memory: 15 Mb.<br />

Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V,<br />

A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current<br />

imbalance (THD and individual to 48th ) and Flicker. Total energy, tariffs,<br />

maximum demands, and transient and sub-cycle disturbances. Included<br />

software provides graphs and summaries to PC. Download files while<br />

logging USb interface. A pC using Windows 95, 98, NT4, WIN2000 or xp<br />

O/S, is required with the CHK powerView software to configure this unit<br />

before operating.<br />

pOWer analySerS & recOrderS<br />

GridSense CHK PM30 Plus 3 Phase Powermonic Logger/<br />

Logger<br />

CHK,pM30pLUS AU<br />

Weatherproof Ip65 field unit. Channels 3 voltage, 63-440V (isolated), 4<br />

current 0 to 3kA (3ph & neutral) rms. Supplied with 3 x flexible 3kA clampon<br />

CTs (flexible CT length 600mm & 190mmØ). Clamp-on CTs of 3kA,<br />

1kA for large conductors and 500A & 100A for neutral conductor current<br />

measurement are available. Memory 4 Mb. Inbuilt 2 line LCD display.<br />

Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to<br />

48th ). Total energy, tariffs, maximum demands, transient and sub-cycle<br />

disturbances. Software provides graphs and summaries to PC. Download<br />

files while logging via RS232 interface. pC using Win 95, 98, NT4, 2000,<br />

xp, O/S, is required with the CHK pOWERview software to configure this<br />

unit before operating.<br />

�������<br />

���������<br />

�������<br />

���������<br />

��������������������<br />

��������������������<br />

�����������������������������<br />

�����������������������������<br />

���������������<br />

���������������<br />

�������� ����<br />

the latest addition to the rugged, weatherproof and versatile<br />

powermonic range has ��� ��� ��� ���<br />

features including:<br />

• flicker monitoring<br />

• interharmonics<br />

• voltage unbalance<br />

• increased memory capacity (15mb)<br />

• larger lcd display<br />

• real-time data display<br />

• compliance to all iEc pq standards<br />

• high-speed usb data transfer<br />

Other features include:<br />

for more information visit - http://www.gridsense.net�<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

• tables & graphs of 3 phase v,a, pf,dpf, kw, kva, kvar, thd,<br />

harmonic phase angle, individual harmonics, interharmonics,<br />

frequency, all to iEc standards<br />

• total Energy & tariffs calculator<br />

• ability to capture motor starts, high speed rms & waveform<br />

disturbances<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 55


ELEC<strong>TR</strong>ICAL POWER<br />

56<br />

pOWer analySerS & recOrderS<br />

CHK PM30 3 Phase Powermonic Power Logger<br />

CHK,pM30 AU/NZ<br />

Weatherproof Ip65 field unit. Channels 3 voltage, 63~440V (isolated), 4<br />

current 0~3kA (3ph & neutral) rms. Supplied with 3 x 1kA clamp-on CTs<br />

(cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors<br />

and 500A & 100A for neutral conductor current measurement are available.<br />

Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA,<br />

kVAr, kW, harmonics, (THD and individual to 48th ). Total energy, tariffs,<br />

max demands, transient and sub-cycle disturbances. Software provides<br />

graphs and summaries to PC. Download files while logging via RS232<br />

interface. pC using Win 95, 98, NT4, 2000, xp, O/S, is required with the<br />

CHK POWERview software to configure this unit before operating.<br />

CHK PM20 Power Quality Analyser/Logger<br />

CHK,pM20 AU<br />

Three phase, weatherproof Ip65 field unit. Three voltage channels 63~440V<br />

(isolated). Four current channels 0~3kA rms (3ph & neutral). Supplied with<br />

3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and<br />

500A for neutrals clamp-on CTs are available. Memory 4Mb. In-built 2 line<br />

LCD display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and<br />

tariffs, high speed rms waveform capture events outside preset limits (10ms<br />

intervals). Software provides graphs and summaries to PC. Download<br />

files while logging. RS232 interface. pC using Win 95, 98 or NT4 O/S, is<br />

required with the CHK POWERview software to configure this unit before<br />

operating.<br />

CHK 3 Phase Converter for CTs 1A Input to 200mA Output<br />

CHK,CK1 AU<br />

Adaptor for CTs with 1A secondary outputs, this unit suits CHK,pM30/20.<br />

External Modem 56k Remote Communication for CHK,PM30/<br />

PQA<br />

CHK,MODEM-56K AU<br />

External modem 56k for CHK pM20, CHK pM30, CHK pM30pLUS or any<br />

other power quality analyzer. Modem gives remote access control to setup/download<br />

any connected Instrument.<br />

CHK 3 Phase Converter for CTs 5A Input to 200mA Output<br />

CHK,CK5 AU<br />

Adaptor for CTs with 5A secondary outputs, unit suits CHK,pM30/20.<br />

CHK CR100 Clamp-on CT<br />

CHK,CR100 AU<br />

Jaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CR500 Clamp-on 500 CT<br />

CHK,CR500 AU<br />

Jaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CT1000L Large 1kA Primary Clamp-on CT<br />

CHK,CT1000L AU<br />

Large 123 x 35mm 1kA primary clamp-on CT for CHK,pM20/30.<br />

Gridsense 3000 Amps Flex CT 600 mm<br />

CHK,CT3000 pLUS AU<br />

CHK CT3000L Large 3kA Primary Clamp-on CT<br />

CHK,CT3000L AU<br />

Large 123 x 35mm 3kA primary clamp-on CT for CHK,pM20/30.<br />

Metrix MX200 ac/dc Clip-on Power Meter<br />

MET,Mx200 AU/MY<br />

Ranges 19.99 & 199.9A. Measures voltage to 750V, frequency to 999Hz,<br />

power 1.99 & 19.99kW, apparent power 1.99 & 19.99kVA, & pf. Recorder<br />

output via special leads (supplied) for current range only, 5mV/A on 199.9A<br />

range. Switch in battery compartment gives ac as well as dc output. Internal<br />

battery for 70h operation. Clamp capacity 23mmØ or 20 x 10mm bars.<br />

Metrix MX2040 ac/dc Clamp-on Meter<br />

MET,Mx2040 AU/NZ<br />

Measures A, V, Hz, kW, kVA, kVAR, kWH, pF and resistance. Ranges 200A<br />

& 2kA, 600V & 1kV, 20, 200kW & 2MW & kWH. Scale length 3,000. 1 &<br />

3ph operation. Motor rotation indication. peak, min, max, average, rms, and<br />

crest factor indication. peak response time 1µs. Analogue output option<br />

fitted giving dynamic signals and calculated parameters (energy, etc).<br />

Martindale Phase Sequence & Continuity Indicator 100~600V,<br />

50/60Hz<br />

MAR,pSCI424-585 AU<br />

Tester may be used, on 3ph circuits, to check the presence & sequence<br />

of the phases. Important on motor circuits as a phase reversal will cause<br />

a motors direction to reverse. Tester will give visual indication of loss of<br />

phase or an incorrect sequence. Tester is supplied in 2 forms - probe style,<br />

the connection to the tester is via 3 insulated cables to 3 fused test probes,<br />

1 with an insulated crocodile clip. plug style, a 16A, 4 pin, 3ph & earth,<br />

bS4343 plug is fitted to the tester. Use as a socket tester prior to plugging<br />

in 3ph equipment. Testers supplied in a plastic wallet, with full instructions.<br />

Caution, the unit should be checked for correct operation using a known<br />

voltage before use.<br />

Yokogawa CW140 Demand/Harmonics Analyser<br />

YEW,CW140 AU/NZ<br />

Includes 4 x 500A clip on current transformers, jaws 30mmØ inside. Current<br />

transformers are accurate at currents of


NEW<br />

Omicron CPC 100 PTS for CTs/VTs/Power Transformer<br />

OMI,CpC100pTS AU<br />

Allows for automated testing of power transformers, CTs, VTs, resistance<br />

testing, and more. providing up to 800A (or 2000A with current booster) and<br />

2000V and comes complete with an integrated PC. Its software routines test a<br />

wide range of substation equipment, and automatically creates customizable<br />

reports. Weight: 29 kg. Analog voltages and currents can be measured with<br />

very high precision. Its Ohm meters automatically switch ranges from µOhm<br />

to kOhm to allow for a wide variety of applications. Testing of unconventional<br />

equipment, such as Rogowski Coils or current sensors completes the<br />

spectrum. Safety features: emergency shut off button, safety key lock (block<br />

unauthorised use).<br />

Omicron CMC156-3 Advanced Protection Relay Test Set<br />

OMI,CMC156-3 AU<br />

For three-phase testing of relays, meters and transducers, for applications<br />

requiring portability. • 3 x 125V outputs, • 3 x 12.5A outputs, • 6 x low level<br />

outputs (rear side), • 2 x counter inputs (rear side), • 4 x binary outputs, •<br />

dc measuring inputs, • 10 x binary inputs. Applications are digital distance<br />

relay testing or testing of transformer operated energy. Signal generation<br />

is performed digitally. The 16-bit D/A conversion results in a high quality<br />

signal event at small signal amplitudes. In addition to the 6 outputs of the<br />

amplifier section, 6 independent channels with low-level signals are available<br />

at the back of the unit which can be used to control external amplifiers for<br />

applications requiring more than 3 voltage or current phases, e.g., testing<br />

of differential relays, or applications requiring higher currents or voltages.<br />

They are also useful where there is a need for output power higher than that<br />

provided by the CMC 156. Comes with Test Universe 2.01 software loaded<br />

on dedicated laptop. Weighs 9.8 kg.<br />

Omicron CMC256-6 EP Advanced 3Ph Protection Relay Test<br />

System<br />

OMI,CMC256-6 Ep AU<br />

Current integral 3ph current source max 140VA, 6 output sources, resolution<br />

500µA, suitable for most relay types, including some high burden units.<br />

Voltage 3 ph voltage 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay<br />

monitoring trip, monitoring 6 isolated inputs, can be configured to be voltage<br />

free or 0~250V. Contact outputs 6 isolated change-over relay contacts<br />

(software controlled). Max 250V ac 10A or 125V dc 1A. Interface connector,<br />

16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated<br />

analogue inputs ±500V peak max 12 bit resolution. Input supply 90~260V<br />

dc, 400Hz. Intuitive on-line help. Notebook 486 or better Win 3.11, 95, 98 or<br />

NT, display SVGA or better. Interface parallel port.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

prOtectiOn relay teSting SyStemS<br />

Omicron CMGPS Syncronisation Control Unit<br />

OMI,CMGpS AU<br />

GpS-based synchronisation unit, which is used to synchronise CMC<br />

(protection Relay) test sets. Used when performing end-to-end tests of<br />

line protection schemes, the unit provides a start signal pulse based on the<br />

GpS clock time base. Software is both integrated in the testing modules<br />

(State Sequencer) and can also be used as a stand-alone application. Two<br />

independent timing pulses are available via separate connectors, on a 16pin<br />

plug (pulse out 1) which is connected with the CMC test set (external<br />

interface) and on 2 x 4mm banana plugs (pulse out 2). Supplied with GpS<br />

antenna, 15m antenna ext cable, plug-in power supply, CMC-CMGpS<br />

interface cable, users manual, fabric carry bag and a travel case. Weighs<br />

5kgs.<br />

Omicron C-Probe-1 Clamp-on CT ac/dc<br />

OMI,C-pRObE1 AU<br />

An active ac & dc current probe with voltage output. Recommended<br />

accessory for measuring currents with the CMC 256. Two measuring ranges:<br />

10A & 80A. Frequency range dc 10kHz. Accuracy error < 2% for currents up<br />

to 40A and frequencies up to 1kHz. phase error < 0.5O @ 50/60Hz. Length<br />

230mm.<br />

Omicron CMC256-6 Advanced Protection Relay Test Set<br />

OMI,CMC256-6 AU<br />

Advanced 3ph dynamic automatic protection relay test system. Current,<br />

integral 3ph current source max 140VA, 6 output sources, resolution 500µA,<br />

suitable for most relay types, including some high burden units. Voltage,<br />

3ph 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay monitoring trip,<br />

monitoring 6 isolated inputs, can be configured to be voltage free or 0~250V.<br />

Contact outputs 6 isolated change-over relay contacts (software controlled).<br />

Max 250Vac, 10A or 125Vdc 1A. Interface connector, 16 TTL digital inputs<br />

and outputs. Scope analogue inputs, 2 isolated analogue inputs ±500V<br />

peak max 12 bit resolution. Input supply 90~260Vdc, 400Hz. Intuitive online<br />

help. Laptop and Test-Universe software up to TU V 2.01 supplied with<br />

test set, interface parallel port.<br />

Programma Sverker 760 Relay Test Set<br />

pRO,SVERKER760 AU<br />

Relay test set for 1ph protective relay equipment. Three phase relays can<br />

be tested 1 phase at a time or by synchronising more than one unit. Current<br />

ranges to 100A with full load current to 250A. AC outputs to 250V & dc<br />

outputs to 300V. In-built capacitor and resistors for current output phase<br />

shifting (360 0 ). In-built timer, ammeter, and voltmeter. Measures phase<br />

angle, PF, and impedance. RS232 communications and control interface.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 57


ELEC<strong>TR</strong>ICAL POWER<br />

58<br />

prOtectiOn relay teSting SyStemS<br />

T&R DVS3-HP Static Relay Test System<br />

T&R,DVS3-Hp AU<br />

Test system for testing voltage and frequency protection relays and<br />

transducers. Tests Automatic Voltage Regulating (AVR) relays with line drop<br />

compensation, under and over voltage relays, directional over~current relays,<br />

df/dt (ROCOF) relays, vector surge (step change of phase) relays and check<br />

synchronising relay. Generates a 3ph voltage output from a 1ph supply,<br />

and may be used in conjunction with a current source to test directional<br />

protection. Requires 1ph 50/60Hz supply of 115V or 230V (±15%). Unit<br />

automatically selects the correct range. Max power requirement of the unit<br />

is 0.5kVA. DVS3-Hp has 3ph star connected output and the rating of each<br />

phase is:- voltage 0~133V phase to neutral, current 5min on/15min off 330mA<br />

@ 133V, or 200mA continuous, phase lock 45Hz~65Hz., variable frequency<br />

40~999.9Hz., variable phase angle ±180 O . Delta loads may be connected<br />

directly to the output or through the DVS-T VT box. Max voltage obtainable<br />

is 133V between any phase & neutral and 266V between 2 phases (if the<br />

phase angles of the 2 phases are set to 180 O apart). DVS-T VT box may be<br />

used to double these output voltage (Ratio 1:2).<br />

Get more done.<br />

> NEW<br />

Programma EGIL Circuit Breaker Analyser<br />

pRO,EGIL-Cb ANALYZER AU<br />

One main contact per phase. Three time channels are connected together<br />

on one side. Events at parallel contacts equipped with pre-insertion resistors<br />

are recorded and displayed simultaneously. Two separate time channels<br />

for measurement of auxiliary contacts. On-site hookup comes with readymade<br />

multi-cable sets for both main and auxiliary contacts. Coil currents<br />

are measured automatically, presented together with other readings<br />

immediately after testing on the display window or via the built-in printer. A<br />

built-in sequencer (program unit) sets the instrument automatically for the<br />

next sequential breaker operation. Intended primarily for measuring travel<br />

(motion). Can be equipped with an optional serial interface (RS232C) for<br />

communication with a pC and the CAbA Win breaker Analysis Software.<br />

More tools for commercial and plant technicians.<br />

Get the job done faster and more accurately with Fluke’s innovative set of tools for electrical<br />

test. From IR thermometers to clamp meters, every rugged tool delivers the reliabilty, accuracy<br />

and safety you expect from Fluke.<br />

Power Quality compliant load studies, energy consumption<br />

testing and general power quality logging.<br />

Verify your power. The Fluke 1735 Power Logger is the ideal technician’s tool for conducting<br />

30-day load studies.<br />

• Set up in seconds<br />

• Measure all 3 phases and neutral<br />

• Log most electrical parameters, plus harmonics and voltage events<br />

More information and resources.<br />

You can always count on Fluke for the troubleshooting techniques, application information, and<br />

training to keep your electrical systems up and running.<br />

Fluke. Keeping your world<br />

up and running.<br />

Power Quality<br />

Analysers<br />

Earth Ground<br />

Testers<br />

Fluke Australia Pty Ltd.<br />

Phone: (02) 8850 3333<br />

Fax: (02) 8850 3300<br />

Email: sales@fluke.com.au<br />

©2006 Fluke <strong>Corporation</strong>. All rights reserved. Ad 01981<br />

Insulation Testers Thermal Images


High Voltage Test Set 30kV/50 Hz AC Hi Pot Tester<br />

HIV,pFT303 AU<br />

Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA<br />

1/2 hours on 2 hours off, at 2 kVA 1 hour on 1 hour off. For a field and repair<br />

shop HV testing applications. Tests the integrity of items including insulating<br />

materials, isophase bus duct, switchgears, transformers, vacuum bottles &<br />

interrupters, vacuum switches, automatic circuit reclosers, bushings, fuses,<br />

arrestors, circuit breakers, transformers, capacitors, motor and generator<br />

windings.<br />

High Voltage PFT503, 50kV ac Test Set<br />

HIV,pFT503 AU<br />

Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA<br />

½h on 2h off, at 2kVA 1h on 1h off.<br />

High Voltage Inc Very Low Frequency (VLF) 6022 60 kV Hi-pot<br />

Test Set<br />

HIV,VLF6022 AU<br />

For field testing of ac high/medium voltage cables, bushings, and insulators.<br />

Input 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0~60kV ac<br />

peak, frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance<br />

1.1µF (approx 3kms of cable at 0.1Hz), 2.2µF (approx 9 of cable at 0.05Hz)<br />

& 5.5µF (approx 13kms of cable at 0.02Hz). Display 0~60 peak kV.<br />

Interconnect cable length 3m, control unit to HV transformer. RG8/U output<br />

cable length 3m. Shorting stick braid 6m. HV tank and control units shipped<br />

in travel cases weighing 70 & 40 kgs respectively.<br />

Baur PGK80 High Voltage (80kVDC) Insulation Tester<br />

bAU,pGK80 AU<br />

Max output 80kV at 0.8mA. In-built timer, zero start interlock and automatic<br />

discharge device.<br />

Megger FT6/12 Ionisation, Leakage and Breakdown Tester<br />

MEG,FT6/12 AU/MY<br />

AC ranges 0~2kV, 0~6kV, dc ranges 0~4kV, 0~12kV. Output currents<br />

7.4mA, 8.9mA ac & 2.1mA, 2.5mA dc. breakdown and flashover indication<br />

by latching indicator for periods exceeding 1ms. Current threshold<br />

100µA~1mA. Ionisation indication by internal speaker. Meter indication of<br />

ac, dc and ac capacitive currents. Complete with probes.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

hi pOt teSterS<br />

T&R kV30-40, 30kV ac Hipot Test Set<br />

T&R,KV30-40 AU<br />

0~30kV, max output 40mA with a duty cycle of 5min on & 15min off. Max<br />

continuous current 20mA. Overload trip may be set from 4~44mA. Zero<br />

interlock and key operated safety features.<br />

High Voltage Test Set VLF 90 Kv<br />

HIV,VLF90 AU<br />

Very low frequency (VLF - 90 CM) ac hipot test set with 90kVac peak output,<br />

is suitable for testing cables up to 50kV. High load capacity enables it to test<br />

up to approx 7 miles of cable, depending on type. Model includes a charging<br />

current and load capacitance meter, test dwell timer, and polarity indicating<br />

lights. Output voltage & frequency,- sinusoidal 0~90kVac peak & selectable,<br />

0.1, 0.05,0.02Hz. Test frequency and rated loads with approximate cable<br />

lengths are:- 0.1Hz/0.55µF 1,673m of cable, 0.05Hz/1.1µF 3,353m of cable,<br />

0.02Hz/2.2µF 6,706m of cable. Kilovoltmeter scaled 0~100kVac peak,<br />

ammeter scaled 0~100mAac & 0~6µF load capacitance. Weight of the unit<br />

167kgs. HV Cable output is 6m flexible, shielded x-ray with alligator clamp,<br />

inter connect cable length 3m, shorting stick 6m lead with clip.<br />

High Voltage Inc VLF 4022 40kV Hi-pot Test Set<br />

HIV,VLF4022 AU<br />

For field testing of ac medium voltage cables, bushings, and insulators.<br />

Consists of control unit and HV tank. Input: 230V, 50Hz, 6A peak, 2.5A<br />

average. Output sinusoidal, 0~40kVac peak, frequency 0.1, 0.05 & 0.02Hz.<br />

Duty continuous. Test load capacitance 1.1µF (approx 3kms of cable at<br />

0.1Hz), 2.2µF (approx 9kms of cable at 0.05Hz) & 5.5µF (approx 13kms<br />

of cable at 0.02Hz). Display 0~40 peak kV. Interconnect cable length 3m.<br />

RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control<br />

in travel cases weighing 50 & 35kgs respectively.<br />

Danbridge Type JP30A Insulation Tester<br />

DAN,Jp30A AU/NZ<br />

DC high voltage insulation tester. Output voltage 0~3kV, 0~10kV, 0~30kV,<br />

in 3 ranges. Max output short circuit 2µA. Audible indication of ionisation.<br />

Current and voltage meters which may be used to calculate resistance.<br />

Megger BM80 Insulation Tester<br />

MEG,BM80 NZ<br />

Analogue/digital insulation and continuity tester. Insulation test voltages are:<br />

50, 100, 250, 500, 1,000Vdc. Resistance resolution is 0.01 MΩ. Voltage<br />

range is 0~600Vac.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 59


ELEC<strong>TR</strong>ICAL POWER<br />

60<br />

electrical tranSducerS<br />

Model Type Input Type (V) Input Ranges Output (V)<br />

CAT,CL-8-36 pH STICK Indoor two-pole tester 2~36kV<br />

MEG,DH2-6M Duplex handspikes for 10AmΩ meter 30Vac/dc 20A max.<br />

HIO,9661-01<br />

500A<br />

Clamp-on sensor<br />

HIO,9669-CCT-1000A 1,000A<br />

HIO,9667-FCT-5000A Flexible clamp-on sensor 500A/5,000A<br />

UNI,p75-3C HYbRID-Dp<br />

2Vac/dc 7,5000A/1.5V<br />

500-mVac<br />

HIO,3290CLAMpONAC/DC Clamp-on<br />

dc to 15kHz 2840A peak 1mV/A<br />

CHK,CR100S 100A<br />

LEM,CURRENT pRObE10A<br />

YEW,3228-11 High sensitivity clamp-on ammeter ac/dc current 50mA, 20A ac/dc 0~100mV ac/dc<br />

ALG,C173<br />

High sensitivity clamp-on ammeter & earth<br />

leakage<br />

Algodue only 0.001 ~ 1,000A 1mV~1V/A<br />

HIO,3128 Clamp-on ammeter ac current 15A, 1.5kA 0~200mV dc<br />

HIO,3285<br />

200A, 2kA, 1kHz 0~1 ac/dc, 0~1 V<br />

bEL,CG-120A 50, 500A 0 ~ 0.5 ac/dc<br />

ac/dc current<br />

UNI,p75-3C Current clamp<br />

4, 7.5kA 0~2/ 0~1.5 ac/dc<br />

HIO,3109 100, 250, 500,1kA 0~1 dc<br />

CHA,D35N<br />

1, 2, 3kA 0~5A ac<br />

FLU,80I,100S 0~10, 0.5~100, 5~1000A 1mA/A<br />

YEW,2215 Current shunt<br />

ac current<br />

1A, 1kA 0~50mV ac<br />

JR,CT-005 ac current dc volts 1, 2, 5kA 0~1dc<br />

ROb,543<br />

Rogowski coil<br />

1A ~ 2MA 0~2 ac<br />

LEM,LEM-FLExII 30, 300, 3kA 0~3 ac<br />

LG,FIC-51E True RMS transducer<br />

500V 0~5 dc<br />

<strong>TR</strong>,M05 Instrument transformer ac voltage<br />

100V, 500V rms 0~5 ac rms<br />

YEW,2261-01 Med voltage transformer (3.3kV) 220, 440V,2.2, 3.3kV 0~110 ac<br />

MOR,FDT<br />

0~20ac 50~1.6kHz 1~5 dc<br />

CI,253/50<br />

0~1mA<br />

Frequency transducer<br />

240 ac 45~55 Hz<br />

CT,891040-240 0~10 V dc<br />

CT,891040-110 110 ac 55~65 Hz 0~10 V dc<br />

CWE,230V Transducer ac voltage 230V 1mV/1V<br />

CAR,3-<strong>TR</strong>ANS Converter ac current 5A 0~10V dc<br />

> NEW CATU C-8-36 Phasing Stick-Two pole Phase<br />

comparator for Indoor Use<br />

CAT,CL-8-36 pH STICK AU<br />

Detect differences in voltage between any 2 points of an installation indicated<br />

by LED’s. Enables assessment of the residual voltage induced by nearby<br />

live lines or circuits, and differentiates it from the one provided directly from a<br />

high voltage source. Features, range of voltages 2kV~36kV, high luminosity,<br />

compact 0.62m with probes dismounted, high dielectric quality insulating<br />

material, 2 x 1.25m elements with removable probes, connected via a highinsulation<br />

lead, max use distance 2.25m (with probe extenders), operation<br />

testing with a checking device.


NEW<br />

Megger DH2-6 Test Lead, 6m long for 10A mΩ Meters<br />

MEG,DH2-6M AU<br />

Duplex handspikes (2) with spring loaded helical contacts test lead suitable<br />

for any 10AµΩ meters (like MEG,DLRO10, MEG,DLRO10x, CRO,DO7<br />

and CHK,LMO5), Used for 4 terminal measurements with low resistance Ω<br />

meters, double, individually sprung, hardened and nickel plated, spike prods<br />

for good contact. potential lead and spike marked for easy identification,<br />

suitable for use in potentially corrosive conditions. Body moulding resistant<br />

to aviation “phosphate ester” fluids. Current rating: 20A max. Working<br />

voltage: 30Vac/dc. Resistance of leads: each lead 20mΩ maximum.<br />

> NEW<br />

Hioki 9661-01 CCT-500A Clamp-on Sensors<br />

HIO,9661-01 CCT-500A AU<br />

500A rated, 500mVac fs output, jaw 46mmØ. Rated input current 500Aac,<br />

rated output current 0.5Vac, accuracy (at 45~66Hz). Amplitude ±0.5%rdg,<br />

±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency<br />

characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous<br />

550 Arms (45~66Hz), max circuit voltage 600Vac rms (insulated wire).<br />

Dimensions 77w x 151h x 42dmm, cord 3m. Suitable for Hioki models:<br />

3196pQA, 3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any<br />

data logger/scope which takes up to 1.7mVac input.<br />

> NEW<br />

Hioki 9669-CCT-1000A Clamp-on Sensors<br />

HIO,9669-CCT-1000A AU<br />

Jaw 55mmØ, 80mmx20mm busbar. Rated input current 1000Aac, rated<br />

output current 0.5Vac, accuracy (at 45~66Hz) amplitude ±1% rdg, ±0.01%<br />

fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics<br />

66Hz~5kHz (±1%), max. Allowable input continuous 1000A rms<br />

(45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions<br />

99.5w x 188h x 42d mm, cord 3m. Suitable for Hioki models 3196pQA,<br />

3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any data<br />

logger/scope which takes up to 1.7mVac input.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

electrical tranSducerS<br />

> NEW<br />

Hioki Flexible Clamp-on Sensor<br />

HIO,9667-FCT-5000A AU<br />

10Hz~20kHz, 500/5000A rated, 500mVac fs output, jaw 254mmØ max.<br />

Rated input current 500Aac, 5000Aac, rated output current 0.5 Vac, accuracy<br />

(at 45~66 Hz). Amplitude ±2% rdg ±1.2mV, fs is the 3196 range value.<br />

phase ±1° or less. Frequency characteristics 10Hz~20kHz max. Allowable<br />

input continuous 10000Arms (45~66 Hz) max. Circuit voltage 1000Vac rms<br />

(insulated wire). Dimensions 254w x 86h x 30dmm. Sensor length 910mm.<br />

Suitable for Hioki models: 3196pQA, 3197pQA, 3169-20CLAMpONpT,<br />

2331-20RpMS, 8715-01, any data logger/scope which takes up to 1.7mVac<br />

input.<br />

> NEW Universal Technic Clamp-On AC/DC Current Probe<br />

4000/7500A<br />

UNI,p75-3C HYbRID-Dp AU<br />

Ranges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and<br />

external power supply, 3V operation. Safety sockets 4mm. Clamp is<br />

suitable for use with any instrument with an input range of 2Vac or dc, and<br />

an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders,<br />

oscilloscopes, and power quality analysers.<br />

> NEW<br />

Hioki 3290 Clamp-On ac/dc HiTester<br />

HIO,3290CLAMpONAC/DC AU<br />

Current Measurement at dc and from 1Hzac~1000Hz. Current Clamp<br />

Hioki 9693 Clamp-on ac/dc sensor ranges - 20, 200 & 2000A, jaw opening<br />

55mm.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 61


ELEC<strong>TR</strong>ICAL POWER<br />

62<br />

electrical tranSducerS<br />

> NEW<br />

CHK,CR100s Clamp-On CT 100A<br />

CHK,CR100S AU<br />

Suitable for CHK power quality analysers like CHK pM20, pM30, pM30 plus<br />

and pM40.<br />

> NEW<br />

HK,CR200 Clamp-on CT 200A~200mA, 2.2Ω Burden Class I<br />

CHK,CR200 AU<br />

CT 200A~200mA, 2.2W burden Class I, IEC 185-1987. Suitable for any of<br />

the CHK powermonic power Quality Analyser like CHK,pM20, pM30 and<br />

pM30 plus units. Suitable for power cables size diameter up to 50mm.<br />

> NEW<br />

LEM Current Probe 10A~1A for LEM,TOPAS 1000 PQA<br />

LEM,CURRENT pRObE10A AU<br />

Current probe 10A~1A suitable for LEM Topas 1000 power quality analyser.<br />

> NEW<br />

Cambridge Frequency Transducer 45~55Hz 240Vac<br />

CT,891040-240 AU<br />

Frequency transducer from 45~55Hz with analogue output 0~10VDC.<br />

powered from 240Vac only.<br />

> NEW<br />

Cambridge Frequency Transducers 891040 55~65Hz 110Vac<br />

CT,891040-110 AU<br />

Frequency transducer for frequency from 55~65Hz with analogue voltage<br />

output 0~10Vdc. powered from 110Vac only.<br />

Algodue C173 Precision Clamp-on CT Microamps to 1Ka<br />

ALG,C173 AU<br />

High resolution clamp-on CT, for measuring differential and or earth loop or<br />

leakage current. Compatible with Algodue UpM6001 and the later UpM6100<br />

analyser’s fourth current channel. Current range 0.001~1.2, 0.01~12,<br />

0.1~120A & 1A~1.2kA. bandwidth 10Hz~3kHz. Max jaw opening 53mm.<br />

Bell CG-120A Current Gun (Clamp-on Probe)<br />

bEL,CG-120A AU<br />

Clamp-on hall effect current probe. For primary 0~500A ac or dc (two scales<br />

0~50 & 0~500). Frequency response dc to 1kHz. Output 0.5V full scale<br />

suitable for DMMs. Termination shielded 4mm banana plugs. Jaw opens to<br />

accept 19mmØ conductors. battery 9V alkaline typical life 100h.<br />

230Vac to 230mVdc Transducer<br />

CWE,230V AC NZ<br />

Interface with output to 4mm banana male plugs suitable for connecting to<br />

DMM or recorder. Input range: 200~255Vac. Output: 0~255mVdc.<br />

Carrel & Carrel 5A ac to 10Vdc Converter<br />

CAR,3-<strong>TR</strong>ANS NZ<br />

Three ac current to dc voltage transducers for use with 5A CTs and a<br />

recorder or logger. Input is 0~5Aac, output is 0~10Vdc. Accuracy is 0.5%<br />

between 1~5A at 50Hz.<br />

Fluke 1kA ac Current Clamp<br />

FLU,80I-1000S NZ<br />

Three ranges: 0~10A, 0.5~100A, 5~1,000A. Jaw opening is 55mm.<br />

HSI PSD Programable DC isolating interface<br />

HSI,PSD NZ<br />

Transmitter for industrial interfacing to chart recorders and loggers. Input<br />

ranges: 10mV~200V, 50µA~50mA. bi-polar output ranges: -1V, 0~2V, 0~5V,<br />

1~5V, 0~1mV, 0~2mV, 0~5mA, 1~5mA, 0~10mA 4~20mA. Accuracy: input/<br />

output 0.2%.<br />

Shimaden 4~20mA to 0~1V Isolating Interface<br />

SHI,20/0-1 NZ<br />

Suitable for use with chart recorders, loggers and other devices requiring<br />

isolation from 4~20mA process signals.<br />

Hioki 3109 ac/dc Clamp-on Current Meter<br />

HIO,3109 AU<br />

Current meter with recorder outputs. In dc mode is a voltage waveform.<br />

Ranges 100, 250, 500A & 1kA. Measures to 2kA with reduced accuracy.<br />

Voltage range 10, 25, 50, 250 & 500 ac/dc. Accuracy 2.5%FSD. Recorder<br />

output 1V/FSD. Operates for 36h from dry batteries or via external ac.<br />

Hioki 3285 ac/dc Clamp-on Meter with Analog Output<br />

HIO,3285 AU<br />

Ranges 200A/2kA ac/dc. Measure volts, ranges 30, 300 & 600V ac/dc.<br />

Frequency ranges 10, 100Hz & 1kHz. Display LCD, counts max 2,500<br />

current, 3,750 voltage and 1,250 frequency. Output voltage 1V for 2,000<br />

count fs for each current range, can select Rec rms output, response time<br />

about 250ms rise time, fall about 500ms. Select Mon for waveform output.<br />

1V is produced for 1,000 count on full scale frequency range. Output not<br />

available for voltage measurements. Supplied with signal output cord, 4mm<br />

to BNC convertor, carry case and ac adaptor. Powered with internal 9V<br />

battery or ac adaptor.<br />

Yokogawa 3228-11 Clip-on Ammeter<br />

YEW,3228-11 AU<br />

High sensitivity, 9 ranges 50mA~20A. AC or dc operation. Frequency range<br />

40Hz~1kHz. battery operated. Analogue output at full scale 100mV rms.<br />

Landis & Gyr FIC-51E Voltage Transducer<br />

LG,FIC-51E AU<br />

AC voltage to dc voltage transducer. Max input 500V. Output voltage 1Vdc<br />

per 100Vac input.<br />

Tech-Rentals,M05 Instrument Transformer<br />

<strong>TR</strong>,M05 AU<br />

Permits monitoring of ac power lines with low input level instruments. Input<br />

100~500V rms. Output 1~5V rms. Distortion less than 0.5%. bandwidth<br />

40Hz~10kHz.


Hioki 3128 Clamp-on Current Transducer<br />

HIO,3128 AU<br />

Clamp-on current meter with recorder output. Ranges full scale 15A~1.5kA.<br />

Output 200mV dc full scale. Batteries not required. Output is intended only<br />

for low speed recorders.<br />

Yokogawa 2255-01 10A ~ 5A Current Transformer<br />

YEW,2255-01 AU<br />

Input 10Aac, output 5Aac, max circuit voltage 3.45kV, burden 15VA, accuracy<br />

1% of rated value, bus bar connectors.<br />

Yokogawa 2215 Current Shunt<br />

YEW,2215 AU/MY<br />

50mV output, available in range of 1A~1kA.<br />

Crompton 235/50 Frequency Transducer<br />

CI,253/50 AU<br />

Input 240V ac, 45~55Hz, output 0 ~1mA.<br />

Moore FDT Frequency to Volts Transducer<br />

MOR,FDT AU<br />

Input range 6.5~12.5kHz at up to 20V peak to peak. Output 5Vdc at<br />

12kHz.<br />

Yokogawa 2261-01 2.2kV Potential Transformer<br />

YEW,2261-01 AU<br />

3.3, 2.2kV, 440 & 220V primary to 110V secondary.<br />

Jacobs Radio CT-005 Current Transducer<br />

JR,CT-005 AU<br />

Range 5kA, 2kA & 1kA. 1V dc output. Transformer can be split in two to<br />

accommodate cable or bus 22 x 55mm.<br />

Phase Sequence Meter 110 - 600 volts 50 / 60 Hz<br />

KYO,pSM8031 AU<br />

KYO,8031 MY<br />

phase indicator with open phase checker and phase indicator designed to<br />

check the presence of open phase and also the phase sequence by rotating<br />

disk and lamps. Check a wide range of 3ph power source from 110~600V.<br />

Operational voltage 110~600Vac, time limit for continuous >500V within 5min.<br />

Frequency response 40~200Hz(ac 110~200V), 40~400Hz(ac 200~600V)<br />

safety standard IEC61010-1 CAT.III 600V pollution degree 2 withstand<br />

voltage 2.2kVac for 5s. Dimensions 106L × 75W × 40Dmm, weight 350g<br />

approx. Cord 1.5m(R: red S: white T: blue)<br />

Beha 5774E 3 Phase Sequence/Rotation Indicator<br />

bEH,5774E AU<br />

For determing the rotational direction and sequence of a 3ph supply.<br />

Necessary to pre-determine the correct rotational direction of 3ph motors.<br />

Kikisui PLZ1002W Electronic Load<br />

KIK,pLZ1002W AU/MY<br />

Voltage range 3~110V. Current range 0~200A. In-built oscillator provides<br />

for dynamic load testing by switching between two different load levels.<br />

Load current may be remotely controlled by voltage or resistance signals.<br />

Multiple units may be operated in parallel. In-built digital volt/current meter.<br />

For dc inputs only.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

electrical tranSducerS<br />

Universal Technic P75.3C dc/ac Amp Clamp<br />

UNI,p75-3C AU<br />

Max current 7,500A dc & ac peak. bandwidth 1KHz. Min range 1kA.<br />

Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size<br />

122 x 54mm or 100 x 64mm. Max cable size 83mm. battery 9V - life 100h.<br />

Output sockets 4mm. DC current gives dc output, ac current gives ac output,<br />

4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.<br />

Robinson 543 Linear ac Current Transducers<br />

ROb,543 AU<br />

Wide bandwidth and very wide dynamic range. Supplied with an open<br />

ended flexible coil of 3m length which may be wrapped around a very large<br />

conductor or power pole, etc. Frequency range 10Hz~10kHz with 1%<br />

accuracy. Current range for 1 wrap of coil 1A~2MA at 50Hz. phase error<br />

< 0.04deg. Min bending radius 60mm. External insulation is required for<br />

metallic conductor. Output voltage 2V rms ac waveform. Also dc rectified<br />

output. In-built digital display.<br />

LEM FLEXII 30, 300 & 3,000A Transducer<br />

LEM,LEM-FLExII AU<br />

Flexible wrap-around ac current transducer. Length 600mm. Ranges 30,<br />

300A & 3kA. Frequency response 1~20kHz. Accuracy 1%. phase error<br />

0.5O. Output 3Vrms @ full scale. Requires 3 units for 3ph. Designed for<br />

multimeters and oscilloscopes (4mm banana plug or bNC connectors) but can<br />

also be used with the DRA,808 (requires adaptor lead), or VOL,pM3000A.<br />

Other instruments may be attached providing the correct adaptor/transducer<br />

and connection is available. Operates for 100h from 2 x 9V batteries.<br />

electrical teSterS<br />

Biddle 550005 Turns Ratio Test Set<br />

bID,550005 AU<br />

Single phase (can be used on 3ph individual phase windings). Turns ratio<br />

0.001~129.999. Exciting current 0~1A. Accuracy 0.1%. Hand cranked<br />

operation.<br />

AVO Penta-Plus DMM Analyser<br />

AVO,pENTA-pLUS-DMM AU<br />

Multifunction meter for measuring 1 & 3ph volts ac, primary and secondary<br />

current, true and reactive power, amplitude and phase angle, and also<br />

frequency. Easily configured to measure the amplitude and phase angle<br />

between any 2 current or voltage inputs. Displayed simultaneously on a<br />

backlight graphic LCD screen. Internal memory records up to 60 test results.<br />

Logging via RS232C port. parallel printer port. Voltage 0~650Vac, 9 ranges<br />

with 0.1% resolution. Max 1kV. Current 0~100A ac in 11 ranges, with 0.1%<br />

resolution. phase angle 0~360O with 0.1O resolution. power true and<br />

reactive ±0-100kW & ±0~100kVAr. Frequency 45~65Hz. Timer 0~999.999.<br />

Line or battery operated, 3h continuous on full charge.<br />

Metrix MX120 Multicore Clamp-on Meter<br />

MET,Mx120 AU<br />

Measures current in 1, 2, or 3 wire cables. No need to split cables or remove<br />

covers. Ranges 2 or 3 wire 0~40A, 1 wire 0~199.9A resolution 0.1A.<br />

Accuracy 5% with 2 or 3 wire oval or flat cable, 12% with round cable, 1.5%<br />

with single wire. battery operated. Display 3½ digit.<br />

Hioki 3282 Clamp-on Hi Tester (V, I, Hz & T)<br />

HIO,3282 AU<br />

Measures True rms, peak, min/max & hold. Ranges auto/manual, current<br />

30A, 300A & 1kA rms. Voltage 300/600V (1kVmax). Resistance 1/10kΩ.<br />

Frequency 40~100Hz & 66Hz~1kHz. Jaw capacity 46mmØ (50mm opening).<br />

Battery life approx 1.5h continuous.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 63


PCU1-SP and PCUI-LT<br />

Primary Current Injection Systems<br />

www.maceyselectrical.com<br />

Features<br />

PCU1-SP and PCU1-LT<br />

• 5kA maximum output current<br />

(higher overload currents for 2s)<br />

• Multi-function digital timing system<br />

• Digital true RMS memory ammeter<br />

• Solid state switching<br />

• 2000A and 5000A loading units<br />

• Three range outputs on loading units<br />

• Rugged, compact design<br />

• Optional trolley mounting of system<br />

PCU1-SP Additional Features<br />

• Secondary injection up to 100A<br />

• Direct reading CT ratio and polarity


electrical teSterS<br />

Hioki 3283 Clamp-on Leakage Current Tester<br />

HIO,3283-LEAKAGE-TES AU<br />

Analyser functions for filtering and output signals. Wide bandwidth<br />

5Hz~15kHz, high sensitivity with a full scale of 10mA, ranges 10mA, 100mA,<br />

1A, 10A & 200A primary. Resolution 10µA, high accuracy at ±1%,True rms<br />

measurement. Output monitor and record modes, ac/dc output 1~2V full<br />

scale. battery 9V approx 40h.<br />

current injectOrS<br />

SMC PET-100-C Secondary Current Test Set<br />

SMC,pTE-100-C AU/NZ<br />

AC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A &<br />

10V/100A. Additional outputs ac voltage 0~220V at 1A (4A 1min), dc voltage<br />

0~350V at 0.7A (2.8A 1min), dc voltage 0~250V at 0.25A, fixed 110V ac at<br />

0.3A. Timer 1ms~99,999s. Additional functions include measurement of<br />

the phase angle between the voltage and the current output tap selected,<br />

and the measurement of the impedance of the load connected in the current<br />

output taps.<br />

Multi-Amp MS-2 High Current Test Set<br />

MUL,MS-2 AU<br />

Designed to test overload relays, circuit breakers and earth fault trip devices.<br />

Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A,<br />

24V/25A, 6V/120A & 3V/240A. Short term over current of several times the<br />

rated current ranges is possible. Digital current meter has read and hold<br />

facilities for short duration currents. Digital timer measures elapsed time<br />

between energisation and the test device operating.<br />

> NEW T&R PCU1-SP with CT Ratio/Polarity and NLU5000A<br />

Loading Unit<br />

T&R,pCU1-Sp NLU5000A AU<br />

Medium powered primary current injection system. Features 5kA maximum<br />

output current (higher overload current for 2s). Multi-function digital timing<br />

system. Digital true RMS memory ammeter. Solid state switching. 2000A<br />

and 5000A load units. Three range outputs on loading units. Rugged,<br />

compact design. Optional trolley mounting of system. Secondary injection<br />

up to 100A. Direct reading CT ratio and polarity. May be configured to either<br />

give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V<br />

range or 1250A on the 9.2V range.<br />

T&R PCU1/E 2000 A Primary Current Test Set<br />

T&R,pCU1/E AU<br />

Comprises control unit and 2kA loading unit. Control unit includes timer,<br />

current and voltage meters, and variable output transformer. Current output<br />

to 100A at 5V ac, 50A at 10V ac. Voltage output to 25A at 240V ac. External<br />

loading unit output to 30A at 240V ac. Outputs 2kA at 0~3V, 1kA at 0~6V.<br />

Two units: weigh 35 & 45kg plus cables.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Equimp HT2035 Electrical Tester<br />

EQU,HT2035 NZ<br />

Complies with CEI 64-8 & CEI 64-4. Eight instruments in the one case which<br />

includes printer & RS-232C interface.<br />

Tests are:- 1. Low Ω range 0~20Ω, resolution 0.01. 2. 2 & 3 wire earth<br />

resistance measurement, range 0~1,999Ω. 3. Insulation resistance<br />

0~199.9MΩ, 250, 500 & 1,000V. 4. RMS ac 0~500V, resolution 1. 5. Short<br />

circuit loop impedance 0~1,999Ω, resolution 0.01. 6. Fault loop impedance<br />

measurement 0~1,999Ω. 7. Fault loop resistance 0~1,999Ω. 8. RCD<br />

tester.<br />

T&R 200 ADM Current Injection System<br />

T&R,200ADM AU<br />

Single phase portable current injection system with main and auxiliary ac,<br />

dc current and voltage outputs. Output ranges main voltage, 10, 35, 100<br />

& 240Vac & 240Vdc. Main current continuous, 1~25A, intermittent up to<br />

200A. Auxiliaries stabilised dc isolated and protected 1.04A @ 24V~0.11A<br />

@ 220V. Variable 300mA @ 0~130Vac. Resolution 100mV, 1mA, phase<br />

0.10. Timing range 0~999.999 with resolution 1ms. Metering LCD backlit<br />

true rms with a memory ammeter. Interface RS232. Protection main output<br />

duty cycle and auxiliaries, electronic thermal and fuse. Supply requirements<br />

1ph 115~230Vac 50/60Hz 2.3kVA max.<br />

T&R CIT/LU2000 Primary Current Injection Test Set<br />

T&R,CIT AU<br />

Comprises control unit and 2kA loading unit (LU). Control unit includes<br />

timer, current and voltage meters, and variable output transformer. External<br />

loading unit output 0~2kA, duty 5min on 15min off at 6V ac, continuous<br />

0~1kA at 3V ac. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets<br />

each 3m long. Control unit connects to LU with supplied interface cable.<br />

T&R 200A-3PH/ED 3 Phase Current Injection Tester<br />

T&R,200A3pHEDIT AU<br />

0~200A/phase output capacity. power supply 4 wire 5A/phase 3ph 240/415V.<br />

Typically 10A 5 pin 3 phase socket outlet HpM.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 65


ELEC<strong>TR</strong>ICAL POWER<br />

66<br />

pOWer line cOnditiOner/upS<br />

Model Type Capacity (VA)<br />

COM,T700UpS<br />

pOW,700VAUpS 700<br />

ApC,1102 1,000<br />

EAT,9120-2KVA 2,000<br />

Sb,0610-2000A 2,000<br />

Sb,0610-3000VA UpS<br />

3,000<br />

CHL,2200 2,200<br />

CHL,ACTIVE2000 2,000<br />

CHL,ACTIVE3000<br />

ApC,SU3000<br />

CHL,5000 5,000<br />

Sb,66-102-8<br />

2,000<br />

Conditioner<br />

Sb,210-26-725 2,500<br />

Sb,63-25-735 3,500<br />

HIO,bATTERYTEST Battery<br />

Sb.625-bATT battery pack<br />

> NEW<br />

Powerware 700VA/420W Line Active UPS<br />

pOW,700VAUpS AU<br />

protection in the 700~3000Va range. Input Voltage Range: 120/140/160-<br />

276 Vac. Frequency 45~65 Hz. plug and play tower, under monitor, or 2U<br />

rackmount. Line-interactive.<br />

Sola 66-102-8 2kVA Electronic Power Conditioner 2kVA<br />

Sb,66-102-8 AU<br />

Input voltage 240V +15% & -25%. Efficiency 94%. Distortion 0.5%.<br />

Sola 210-26-725 2.5kVA Power Conditioner<br />

Sb,210-26-725 AU<br />

Input range 240V ±40% for +5% & -8% regulation. Max distortion on linear<br />

loads 3%, on typical computer loads 5%. Efficiency 90%.<br />

Sola 0601-2000A 2kVA On-line UPS<br />

Sb,0610-2000A AU<br />

Sb,0610-2000VA NZ<br />

Run time 10min or 25min at half load. Novell/RS232 communications<br />

interface included providing relay contacts for mains failure and low<br />

battery, input for remote shut down, and RS232 send/receive, all via a Db9<br />

connector.<br />

APC Pro 1000 UPS<br />

ApC,1102 NZ<br />

1 KVA line interactive ups with built-in filters for sags, surges and transients.<br />

Switches to battery power in 20ms in the event of a power outage.<br />

Compaq On-line 700 Watt UPS<br />

COM,T700UpS NZ<br />

Eaton Corp Powerware 9120 2kVA Online UPS<br />

EAT,9120-2KVA NZ<br />

The double conversion online PW9120 with its wide input voltage is capable<br />

of working with mains power in most conditions without discharging batteries.<br />

Capacity 2kVA 12min IEC 10 A 5 Aust 10A 215 x 470 x 365 mm.<br />

Sola 625 Battery Pack<br />

Sb,625-bATT NZ<br />

Sola 625-3000VA On-line UPS<br />

Sb,625-3000VA NZ<br />

Output regulation is ±3%, run time at full load is 8min or 20min at half load.<br />

125% overload capacity for 10s.<br />

Sola Basic 3500VA 110V OP Power Conditioner<br />

Sb,63-25-735 NZ<br />

3500VA fero resonant power conditioner. 230V input and 110Vac output.<br />

Filters out sags, surges and transients.<br />

APC SU3000 3kVA On-line UPS<br />

ApC,SU3000 AU<br />

Run time 5min at full load. Network software included. Weight 60kg.<br />

Chloride Powerlan 2.2kVA UPS<br />

CHL,2200 AU<br />

Sinewave output. Dual pC interfaces. Typical run time 10min. Weight 43kg.<br />

Vigilant 7 network interfacing software included.<br />

Chloride Powerlan 5kVA UPS<br />

CHL,5000 AU<br />

Sinewave output. Dual PC interfaces. Typical run time 10min. Weight<br />

120kg. Vigilant 7 network interfacing software included.<br />

Chloride Active 2kVA Double Conversion UPS<br />

CHL,ACTIVE2000 AU<br />

Double conversion sinewave output. Dual PC interfaces. Typical run time<br />

20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V<br />

ac 1ph + N ±3%. Efficiency >88%. Dimensions 200w x 875d x 350hmm.<br />

Weight 81kg. MopUpS professional software for system monitoring and<br />

shutdown included. USb port & RS232 communication port for UpS<br />

monitoring and management.<br />

700<br />

3,000


Chloride Active 3kVA UPS<br />

CHL,ACTIVE3000 AU<br />

Double conversion sinewave output. Dual PC interfaces. Typical run time<br />

20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V<br />

ac 1ph + N ±3%. Efficiency >90%. Dimensions 200w x 875d x 350hmm.<br />

Weight 81kg. MopUpS professional software for system monitoring and<br />

shutdown included. USb port & RS232 communication port for UpS<br />

monitoring and management.<br />

> NEW Dimmer Dot Variable AC Voltage Auto Transformer 3<br />

Phase 23~28A<br />

VAR,D-283-Ob AU<br />

Manual operated air cooled; Input 400/415V, 50Hz. Output 0~415/470V.<br />

23-28A. Total Weight 95kgs.<br />

Ferguson 115-2000 2kVA 240/115V Transformer<br />

FER,115-2000 AU<br />

Ferguson 115-1,000 240V 1kW Transformer<br />

FER,115-1000 AU<br />

240~115Vac, 1kVA stepdown transformer.<br />

pOWer line cOnditiOner/upS<br />

Hioki Battery HiTester<br />

HIO,3551bATTERYTEST AU<br />

Takes on-the-spot measurements of the internal resistance, voltage<br />

and temperature of lead-acid batteries, principally for UpS and similar<br />

applications, without needing to shut off the battery. Instantaneous results,<br />

on a three-rank scale of pass, Warning, or Fail, using a composite decision<br />

based on the internal resistance and the voltage. Resolution of 1µΩ,<br />

necessary for high capacity batteries (of at least 500Ah). Includes Hioki<br />

9460 clip type temperature leads.<br />

Model Type Phases VA Output (VAC)<br />

FER,115-2000 Power Transformer<br />

2,000<br />

1<br />

FER,115-1000 1,000<br />

VAR,D-283-Ob Auto Transformer 3 16,000 0~470<br />

VAR,2000<br />

VAR,3000 Variac<br />

3,000<br />

VAR,16000-3<br />

VAR,6500-3<br />

3<br />

20A/ph<br />

8A/ph<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

pOWer tranSfOrmerS<br />

2000<br />

Variac 2kVA 0~260Vac Output<br />

VAR,2000 AU<br />

Variac 3kVA 0~260Vac Output<br />

VAR,3000 AU/MY<br />

Variac 16kVa-3 3ph 20A<br />

VAR,16000-3 AU<br />

Variac 6500-3 3ph 6.5kVA<br />

VAR,6500-3 AU/NZ<br />

Variac 3ph 6.5kVA. 0~470Vac output for 415Vac input, max current 8A/ph.<br />

115<br />

0~260<br />

0~470 ph-ph<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 67


ELEC<strong>TR</strong>ICAL POWER<br />

68<br />

ac SOurceS/inverterS/generatOrS<br />

Model Type VA Output (VAC)<br />

ELG,501<br />

bEH,bL1350C-2<br />

Elgar 501 ac Power Source<br />

ELG,501 AU<br />

AC power amplifier. Operates from 240V 1ph ac. Output ranges on tapped<br />

transformer 0~65, 0~130, 0~260Vac. Output power 500VA. Alternative<br />

oscillators available for 10Hz~10kHz operation. Amplifier output rated over<br />

45Hz~5kHz. Two units may be connected for 1kVA output. Three units may<br />

be used with a single 403 oscillator to give a 3ph output at 1.5kVA.<br />

Behlman BL1350C-2 1350 VA Power Amplifier<br />

bEH,bL1350C-2 AU<br />

AC power amplifier with oscillator. Max power output 1.35kVA. Max current<br />

10A on 0~135V range, 5A on 0~270V range. Output frequency 45~500Hz.<br />

External frequency synchronising input. Remote 0~10Vdc programming<br />

of output frequency and voltage. Digital true rms readout of voltage and<br />

current. Units may be stacked for higher power or 2 & 3 phase operation.<br />

Honda EU3000is Generator 240V/3kVA Inverter Output<br />

HON,EU3000IS AU<br />

3kVA /240Vac generator inverter type. Working on petrol.<br />

Rediline DA3179 12/240V dc-ac Inverter<br />

RED,DA3179 AU/MY<br />

Motor generator. 12Vdc to 240Vac sinewave output. Continuous rating<br />

400W. Intermittent use 600W. Lower duty cycle 50% on, 25% off, 1.2kW,<br />

auto starts on load. Overload protected. Weight 12kg. Overall frequency<br />

regulation 47~53Hz.<br />

AC power Amp 0~270<br />

RED,DA3179 Motor generator 12 V 400 240<br />

PC,250I Sine Wave Inverter 12 V 250 250<br />

pC,300I-24 power Inverter 24 V<br />

pC,300I-12 Power Inverter 12 V<br />

HON,EU3000is Petrol Generator 3000<br />

YAM,EF3000iSE petrol Generator/Inverter Set 3000<br />

<strong>TR</strong>A,230-115 Transformer 1000 115<br />

300<br />

Power Conversions 250I Inverter<br />

pC,250I AU<br />

250W sine wave inverter. 12Vdc input.<br />

Power Inverter 300W 24Vdc Output 240V<br />

pC,300I-24 AU<br />

Sinewave inverter. Output power continuous (peak) 300W (1kW). Frequency<br />

50Hz ±1%.<br />

230 to 115 VAC Transformer 1 kVA<br />

<strong>TR</strong>A,230-115 NZ<br />

Maximum power is 1kW. USA power socket.<br />

Ebbett 1,5kW DC to AC Inverter<br />

Ebb,12/1500 NZ<br />

12Vdc~240Vac 50Hz sinewave inverter. Continuous rating 1,000VA.<br />

Intermittent use 1,500VA. Surge (motor start) 2,000VA. Overload protected<br />

with automatic soft start. Output 230Vac ±5%. Frequency 50Hz ±0.5.<br />

Three pin outlet socket.<br />

Yamaha EF3000iSE 3kVA Petrol Generator/Inverter Set<br />

YAM,EF3KISE AU<br />

Output ac 3kVA 2.8kW @ 240V 50Hz, max harmonic distortion 2.5% (mains<br />

supply can exceed 5%), 12Vdc @ 14A. Sound attenuated enclosure (level<br />

57db(A) @ 7m) with 4 wheels. Dimensions 680w x 445d x 555hmm. Dry<br />

weight 70kg. Engine 4 stroke, air cooled ohv, fuel tank 13L (unleaded),<br />

duration at 25% load 20h with auto throttle on. Electric and pull start.<br />

240


DATA ACQUISITION & RECORDING<br />

70<br />

data lOggerS<br />

Data Loggers<br />

Analogue in<br />

(Ch)<br />

Digital<br />

in<br />

(Ch)<br />

Digital<br />

out<br />

(Ch)<br />

dc<br />

supply<br />

Voltage<br />

Ranges<br />

RTD<br />

Strain<br />

Gauge<br />

TC Comms Memory<br />

Sample<br />

Rate (Hz)<br />

Flashcard<br />

MB<br />

DE,DT605 10<br />

13.65k<br />

5 5<br />

25mV~100V<br />

RS232<br />

1 SRAM 1<br />

DE,DT605-3 (30 unbal)<br />

166.538k<br />

Yes Yes<br />

DE,DT800<br />

12<br />

10baseT/<br />

64M<br />

16 8 10mV~10V<br />

100kHz 64<br />

DE,DT800-4pRO (42 unbal)<br />

RS232 64M<br />

Yes<br />

Yes<br />

HIO,8421-01<br />

16<br />

Yes<br />

8Mb 256<br />

HIO,8421-51<br />

100mV~60V<br />

No LAN<br />

HIO,8422-51 32 No 8Mb 512<br />

YEW,DA100-40CH 40 20mV~50V Yes RS232 0.5<br />

FOU,DAQpRO<br />

FOU,DAQpRO-2<br />

8<br />

0~50mV<br />

0~10V<br />

Yes No<br />

Yes<br />

J,K<br />

USb 512kb 0~10kHz<br />

TIN,TGpR-0804<br />

4~20mA<br />

RS232 15.9k 1s<br />

TIN,TGpR-0704-10VDC 1<br />

0~10V dc<br />

No No<br />

Comms<br />

RS232C<br />

TIN,TGpR-0704-2.5V 0~2.5V RS232C<br />

Memory Recorders for transient<br />

& continued signals<br />

Analogue in<br />

(channels)<br />

Digital in<br />

(channels)<br />

Chart Paper<br />

(mm)<br />

Chart Speed<br />

(mm/s)<br />

FDD Voltage Ranges<br />

Memory<br />

per ch<br />

HIO,8835<br />

100kW<br />

4<br />

100<br />

HIO,8835-01 1Megaword<br />

16<br />

9 Yes 100mV ~400V<br />

HIO,8841 8 200 1M<br />

HIO,8842 16 200 2M<br />

RS232<br />

No<br />

Sample<br />

Rate<br />

No 1MHz<br />

HIO,8860 8 16 200 20 No No Var<br />

YEW,ORM1300 16<br />

YEW,ORM1200<br />

200 100<br />

Yes<br />

100mV ~500V<br />

YEW,ORp1200 8<br />

3k<br />

128k<br />

100kHz<br />

YEW,DL708E 100 Yes 50mV ~800V 1 M Yes 10MHz<br />

Hybrid & Pen Recorders<br />

Analogue in<br />

(Ch)<br />

Chart<br />

Paper<br />

(mm)<br />

Chart Speed<br />

dc<br />

Supply<br />

FDD<br />

Voltage Ranges<br />

(V)<br />

YEW,3057-22 2 150 10mm/s 10mV – 50<br />

YEW,3712-31 3 250<br />

YEW,3712-41 4 250<br />

1,200mm/min 10mV – 200<br />

TC RTD<br />

Sample Rate<br />

(Hz)<br />

YEW,3750 10<br />

150<br />

Yes<br />

YEW,3750-DC 20 Yes Yes<br />

20mV – 50 0.5 Yes<br />

YEW,3760 30 250 1,500mm/h<br />

YEW,DR130 20 150 Yes<br />

135<br />

RS232<br />

Yes


Fourier DAQPRO 8 Channel Data Logger<br />

FOU,DAQpRO AU/NZ<br />

portable, hand held, battery operated 8 channel data logger. 16-bit<br />

resolution, built in graphic LCD, for setting up, graphical display of logged<br />

data. pC communications via USb interface. Signal inputs 0-24mA, 0-<br />

50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range -<br />

25~150OC, pT100 range -200~400OC, T/C ranges J type, -300~1500OC,<br />

K type -250~1100OC, T type -200~400OC. Frequency input one channel<br />

only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000<br />

counts. Memory capacity 512Kb, sampling rates from 1S/Hr to 4,000S/sec.<br />

Supplied with analysis and setting up software.<br />

Fourier DAQPRO8 Batter Operated hand held 8 Channel Data<br />

Logger<br />

FOU,DAQpRO-2 AU<br />

portable, hand held, battery operated 8 channel data logger. 16-bit<br />

resolution, built in graphic LCD, for setting up, graphical display of logged<br />

data. pC communications via USb interface. Signal inputs 0-24mA, 0-<br />

50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range -<br />

25~150OC, pT100 range -200~400OC, T/C ranges J type, -300~1500OC,<br />

K type -250~1100OC, T type -200~400OC. Frequency input one channel<br />

only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000<br />

counts. Memory capacity 512Kb, sampling rates from 1S/Hr to 4,000S/sec.<br />

Supplied with analysis and setting up software.<br />

DataTaker 1Mb PCMCIA Card for DT Series 2<br />

DE,DT-MEM1024 AU<br />

Memory card for DataTaker DT600 series loggers. Capacity 1.024Mb.<br />

DataTaker DT500/600 Expansion Module<br />

DE,CEM-AD AU<br />

Channel expansion module for DT500 & DT600 data loggers. Adds<br />

10 differential analogue and 20 digital state inputs. Also adds 10 digital<br />

outputs.<br />

DataTaker DT5LTP-R One Channel Logger<br />

DE,DT5LTp-R AU<br />

One channel platinum resistance probe temperature logger. Range<br />

-50~50OC up to 0.1 resolution, -50~250OC up to 0.3 resolution. Memory<br />

store up to 4,048 readings. External probe. Lithium battery.<br />

DataTaker DT800 Data Logger<br />

DE,DT800 AU/NZ<br />

Universal input channels 12 balanced or 42 unbalanced analog channels.<br />

Eight bi-directional digital channels & 8 digital input channels. Solid state<br />

multiplexer protected to ±40V. Max in/out voltage ±12V. Serial sensor<br />

channel can be used with GpS systems. Measures V, 4~20mA, strain, TC,<br />

RTD etc. Sampling rate 200Hz up to 100kHz in burst mode. Instrument has<br />

RS232, RS422, USb, Ethernet (10baseT) & pC card modem communications.<br />

plugable 64Mb memory card stores up to 300,000 (compressed) readings<br />

per Mb. Instrument stores 600,000 (compressed) readings in internal<br />

memory. Total memory capacity 10.2Mb (compressed).<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

data lOggerS<br />

Datataker DT800 Data Logger with Delogger 4Pro & Transit<br />

Case<br />

DE,DT800-4pRO AU<br />

Universal input channels 12 balanced or 42 unbalanced analog channels. Eight<br />

bi-directional digital channels & 8 digital input channels. Solid state multiplexer<br />

protected to ±40V. Max in/out voltage ±12V. Serial sensor channel can be<br />

used with GpS systems. Measures V, 4~20mA, strain, TC, RTD etc. Sampling<br />

rate 200Hz up to 100kHz in burst mode. Instrument has RS232, RS422, USb,<br />

ethernet (10baseT) and pC card modem communications. plugable 64Mb<br />

memory card stores up to 300,000 (compressed) readings per Mb. Instrument<br />

stores 600,000 (compressed) readings in internal memory. Total memory<br />

capacity 10.2Mb (compressed). Supplied with Delogger 4pro & Ip67 pE-800<br />

portable enclosure with mounting frame.<br />

DataTaker DT605 Data Logger<br />

DE,DT605 NZ<br />

Input capacity 100V. LCD display enabling use as a measuring instrument if<br />

preprogrammed for channel parameters. Ten differential or 30 single ended<br />

channels. Channels/sec 25. Digital inputs 4TTL/CMOS. Three counter channels<br />

up to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LED’s. Internal<br />

memory up to 11,000 readings. Optional memory card to 170,000 readings.<br />

RS232C data communications port and RS485 port for networking up to 32<br />

loggers. Maths processing included. Inputs voltage 25mV~2.5Vdc & 100Vdc.<br />

Max sensitivity 2µV. Current 0.25~25mA. Current loop 4~20 mA. Resistance up<br />

to 7kΩ. Thermocouples b, C, D, E, G, J, K, N, R, S and T from -250~1,800OC. Thermistors and RTD’s. Strain gauges. Supplied with Determinal and Delogger<br />

software. Operates from internal battery, external battery or ac mains.<br />

Data Taker DT605-3 Series 3 Data Logger<br />

DE,DT605-3 AU<br />

Input capacity 100V and built in SRAM Card Slot. LCD display enabling<br />

use as a measuring instrument if pre-programmed for channel parameters.<br />

Ten differential or 30 single ended channels. Channels/sec 25. Digital<br />

inputs 4TTL/CMOS. Three counter channels up to 1MHz. Up to 120 alarms<br />

with 1 digital I/O and 3 front panel LED’s. Internal memory up to 166,530<br />

readings. Optional 1Mb memory card to 343,980 readings. RS232C data<br />

communications port and RS485 port for networking up to 32 loggers. Maths<br />

processing included. Inputs V 25mV~2.5Vdc & 100Vdc. Max sensitivity<br />

2µV. Current 0.25~25mA. Current loop 4~20mA. Resistance up to 7kΩ.<br />

Thermocouples b, C, D, E, G, J, K, N, R, S and T from -250~1,800OC.<br />

Thermistors and RTD’s. Strain gauges. Supplied with Determinal and<br />

Delogger software. Operates from internal battery, external battery or ac<br />

mains.<br />

DATA ACQUISITION & RECORDING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 71


DATA ACQUISITION & RECORDING<br />

72<br />

data lOggerS<br />

Hioki 8421-01 16 Channel Data Logger with Colour Display<br />

HIO,8421-01 AU<br />

Sixteen analogue, 4 pulse input channels data logger with colour display,<br />

pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />

real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVdc, 1Vdc,<br />

10Vdc, 60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5~26) R,<br />

S, b, -100~100OC, -200~500OC, -200~2,000OC, RTD pt100 -200~800OC.<br />

Pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts<br />

fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording<br />

interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 &<br />

5min. Max sampling rate is dependent upon type of input signal. Internal<br />

Memory 8Mb, 256Mb Flashcard, 9334 logger communicator software, 9642<br />

LAN cable, 9641 pulse signal input cable all supplied.<br />

Hioki 8421-51 16 Channel Data Logger with Colour Display<br />

HIO,8421-51 AU<br />

Sixteen Analogue, 4 pulse input channels data logger with colour display,<br />

pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />

real time pC logging, FTp, SMTp and HTTp. Signal inputs- 100 mVdc, 1Vdc,<br />

10 Vdc, 60Vdc, 1-5Vdc f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R,<br />

S, b, -100~100OC, -200~500OC, -200~2000OC, RTD pt100 -200~800OC.<br />

Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s,<br />

2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval selectable from<br />

100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max<br />

sampling rate is dependent upon type of input signal. Internal Memory 16MW,<br />

512Mb pCMCIA FLASH card, 9334 Logger Communicator software, 9642<br />

LAN cable, 9641 pulse signal input cable all supplied. Improved common<br />

mode rejection- 100db or better when 50/60Hz, 140db or better when 50Hz,<br />

using ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling<br />

when using Pt100, improved temperature characteristics.<br />

Hioki 8422-51 32 Channel Data Logger Logger<br />

HIO,8422-51 AU<br />

Thirty two analogue, 4 pulse input channels data logger with colour display,<br />

pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />

real time pC logging, FTp, SMTp and HTTp. Signal inputs: 100mV, 1, 10 &<br />

60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, b, -100<br />

~100OC, -200~500OC, -200~2,000OC. pulse input, accumulation 50,000<br />

counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs & 2,500M counts<br />

fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200,<br />

500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent<br />

upon type of input signal. Internal Memory 8Mb, 512Mb pCMCIA FLASH<br />

card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse<br />

signal input cable all supplied.<br />

Yokogawa MV200 Twenty Channel Logger<br />

YEW,MV200 NZ<br />

Twenty channel voltage, RTD and thermocouple logger. Color LCD display<br />

10.4” TFT, removable pCMCIA ATA flash memory card. Supports data<br />

collection over ethernet networks. Supplied with RJ-45 cable and standard<br />

software.<br />

Yokogawa Data Logger for PC Acquisition<br />

YEW,DA100-40CH AU<br />

pC based datalogger with dc supply. Channels 40, 50V max input 0.05%<br />

basic accuracy. Accepts RTD and TC inputs. Must be used in conjunction<br />

with a PC includes analysis software. Scan rate 2s.<br />

Yokogawa 2423A Six Channel Logger<br />

YEW,2423A17 NZ<br />

Portable voltage and thermometer logger. Ranges are 10, 1 & 0.1V. Type<br />

K, E, J, T, R, S, b, L, U thermocouples. Memory stores 14,000 data points.<br />

Min logging interval is 10s. Large LCD display, analogue and RS232 output.<br />

Supplied with software for uploading data to CSV or TxT format.<br />

> NEW Hioki 3632-20 Temperature Logger with Internal<br />

Sensor Only<br />

HIO,3632-20 AU<br />

Temperature logger (1 channel) includes 1 x RS232C & 1 x USb<br />

communication base, utility software, RS232C and USb interface cables.<br />

Temperature range -20~+70ºC. Accuracy -20~-0.1ºC +/-1.0ºC. 0~35ºC +/-<br />

0.5ºC, 35.1~70ºC +/-1.0ºC. Internal thermistor sensor, water resilience Ip67.<br />

Built in LCD.<br />

Hioki 3641-20 Temperature/Humidity Logger with RS-232C &<br />

USB<br />

HIO,3641-20 AU/MY<br />

Includes 1 x RS232C & 1 x USb communication base, utility software,<br />

RS232C & USb interface cables. Temperature range -40~85OC, humidity<br />

range 0%~100%RH. Accuracy temperature -40~-0.1OC ±1, 0~35OC ±0.5,<br />

35.1~70OC ±1 & 70.1~85OC ±2. Humidity typical between ±5~±10%RH<br />

depends on temperature and humidity range.<br />

Hioki 3641-20-Kit of 8 Temperature & Humidity Loggers<br />

HIO,3641-20-KIT AU<br />

Kit of 8 x temperature and humidity loggers. Includes 1 x RS232C and 1<br />

x USb communication base, utility software, RS232C and USb interface<br />

cables. Temperature range -40OC~85OC, humidity range 0.0%RH to 100%<br />

RH. Accuracy: Temperature -40~-0.1OC +/- 1.0OC , 0.0~35OC +/- 0.5OC,<br />

35.1~70OC +/- 1OC, 70.1~85OC +/- 2OC. Humidity typical between +/-5 to<br />

+/-10% depends on temperature and humidity range. 8000 data points x 2<br />

channels, recording interval 2,5,10,15,20,30 sec,1,2,5,10,15 ,20,30,60 min.<br />

Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles<br />

FOU,MICROLOG-KIT AU<br />

Set of 5 temperature and humidity loggers mounted in RF transmitter<br />

cradles, one receiver for PC. Transmission range up to 300m or RS232C<br />

& USb interface also included if direct connection to pC for down loading<br />

required. Temperature range -30~50OC, accuracy ±1O, 0~100%RH<br />

accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points<br />

between 2 channels. User defined sampling rate from 10s~2h. MicroLog<br />

Plus management control software included to control and monitor all the<br />

loggers remotely on PC within transmission range.<br />

Escort Temperature Humidity Logger Set of 10<br />

ESC,HUM/T-KIT AU<br />

ESC,HUM-KIT NZ<br />

Includes software and communication base for down loading of data from<br />

loggers to a PC. Data presented in table or graph form. Max sample rate<br />

1min.


Escort Analogue Adaptor<br />

ESC,ANALOGUE NZ<br />

Analogue adaptor for dc voltage and dc current inputs. Inputs: 0~20mA, 0~2<br />

VDC, 0~10Vdc.<br />

Escort Four Channel Temperature Logger<br />

ESC,4 ExT NZ<br />

Range -20~60OC. Resolution 0.3OC. Accuracy 0.5OC. Stores 30,000<br />

readings. Supplied with software, interface and 3m long temperature<br />

sensors.<br />

Escort Three Channel Low Temperature Logger<br />

ESC,3ExT-LO/SS NZ<br />

Range -40~40ºC, accuracy 0.5ºC, resolution 0.3ºC. Supplied with 3<br />

temperature sensors and software.<br />

Escort Internal Temperature Logger<br />

ESC,INT-LO NZ<br />

Single channel low temperature logger. Range -40~40ºC, resolution is 0.5ºC,<br />

accuracy is 0.3ºC. Can be immersed in liquid. Stores 24,000 readings.<br />

Supplied with software and serial interface for uploading data.<br />

Escort pH Adaptor<br />

ESC,pH-ADApTOR NZ<br />

Glass electrode type pH adaptor probe. Range 0~14pH, resolution 0.015pH.<br />

User calibration via offset and slope adjustment screws. Supplied with 10m<br />

temperature compensation probe. WARNING!! Do not use the electrode in<br />

perchlorate, silver, sulphide or any hydrofluoric solutions containing more<br />

than 1M acid or base, or at temperatures more than 50ºC. Use at high<br />

temperatures may shorten the life of the electrode.<br />

Escort Autoclave Logger<br />

ESC,AUTOCLAVE NZ<br />

Temperature logger suitable for use in autoclave sterilizers. Temperature<br />

range is 25~150ºC, resolution: 0.5ºC, accuracy: ±0.5ºC. Rated to 150ºC<br />

for 30min or 125ºC for indefinite. Maximum of 60min endurance for dry<br />

heat oven @ 150ºC. Stainless steel body with 1 external sensor, stores<br />

2000 readings in its memory. IP68 rated to 5bar. Supplied with calibration<br />

certificate, software and serial interface for programing & uploading.<br />

data lOggerS<br />

Tiny Tag One Channel 0~20mA Current Input Logger<br />

TIN,TGpR-0804 AU<br />

Logger 4~20mA single channel. Readings 15,900. Re-scalable Ip68 78w x<br />

50d x 34hmm. Two level alarm leds. Accuracy 0.6% 0.1mA.<br />

Tiny Tag TGPR~0704~10Vdc Data Logger<br />

TIN,TGpR-0704-10VDC AU<br />

Single channel 0~10Vdc logger , 8 bit A to D resolution. Stores 15,900<br />

readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />

Range: 0~10Vdc, max input 14V, accuracy ±40mV, ±1% rdg, 400kΩ<br />

impedance. Battery operated.<br />

Tiny Tag TGPR~0704~2.5Vdc Data Logger<br />

TIN,TGpR-0704-2.5V AU<br />

Single channel 0~2.5V logger, 8 bit A to D resolution. Stores 15,900<br />

readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />

Range 0~2.5V range, max input 3.5V, accuracy ±10mV. battery operated.<br />

Testo 177-H1 Logger with Display<br />

TES,177-H1 MY<br />

parameters: Humidity/Temp/Dew point. Sensors: Humidity Sensor/<br />

NTC(internal). No of Channels: 4 CH. Measuring Range: 0~100%RH &<br />

-20~+70 celcius(internal). Memory: 48,000 readings.<br />

Testo 177-T4 Logger with Display<br />

TES,177-T4 MY<br />

parameters: Temperature(C/F). Sensors: Thermocouple Type-K. No of<br />

Channels: 4 CH(external). Measuring Range: -100~+1000 celcius(external).<br />

Memory: 48,000 readings<br />

inStrumentatiOn amplifierS<br />

Vishay 2100 Eight Channel Instrument Amplifier<br />

VIS,2100 AU<br />

Eight channel signal conditioner/amplifier system comprising 4 dual amplifiers with power supply, digital output display and rack frame. Accepts low level<br />

signals and conditions and amplifies them to drive recorders. bridge balancing for quarter (120 & 350Ω), half & full bridge (50~1kΩ). Quarter bridge dummy<br />

resistors provided. Gain 100~2100. bandwidth dc ~5kHz at 0.5db, 13kHz at 3db. Output ±10V @ 30mA, 50mA into 150Ω, 100 mA into 15Ω. Type 2130<br />

digital readout can be switched to each output in turn and also to an external source. Ranges ±1,999mV & 19,999mV.<br />

Yokogawa ORP1200 8 Channel Memory Recorders<br />

YEW,ORp1200 AU/MY<br />

In-built waveform display. Input ranges 100mV~500V. Max input voltage<br />

is 500V peak or 350V rms ac. Memory 32k per channel, may be combined<br />

for 2 channel 128k operation. Memory may be divided into 16 blocks of<br />

2k. 128k memory at 1kHz sampling (20 points of 50Hz cycle) gives 128s<br />

storage. Real time recording 10mm/hr~100mm/s. Real time recorder with<br />

memory trigger facility. 4 triggers including high, low, rise, fall, with and/or<br />

facility. x-Y operation with up to 4 channels. Memory card facility for storing<br />

memory dumps and setups. Memory card not included.<br />

Yokogawa ORM1300 16 Analogue Channel Memory Recorders<br />

YEW,ORM1300 AU<br />

Similar to YEW,ORM1200 except it has 16 analog channels rather than 8.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

memOry recOrderS<br />

Yokogawa ORM1200 8 Channel Memory Recorders<br />

YEW,ORM1200 AU<br />

Similar to YEW,ORp1200 except it has 128K RAM per channel (ie. 512K<br />

when used as a 2 channel recorder) includes FDD.<br />

Yokogawa DL708 8 Channel Recorder/Digital Scope<br />

YEW,DL708E MY<br />

Eight channels 10M/s sampling 10 bit 8M word of memory, 1.2Gb HDD<br />

(100k/s sampling continuously to disk). In-built printer, FDD, RS232, GpIb<br />

and VGA. Input ranges 5mV/div~200V/div . 800V isolated input capability<br />

(using x10 probes). Input filters, FFT, color display, measurement of 26<br />

waveform parameters. Simple and advanced trigger including a window<br />

trigger.<br />

DATA ACQUISITION & RECORDING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 73


DATA ACQUISITION & RECORDING<br />

74<br />

memOry recOrderS<br />

> NEW<br />

Hioki 8860 8 Channel High Speed Memory Recorder<br />

HIO,8860 AU<br />

High speed memory recorder, 20MS/s sampling rate, 8 analog channels, 16<br />

logic channels, built in printer. 512MW or direct access memory, 60GB hard<br />

drive built-in, pC card type II slot up to 4Gb ATA flash card (optional) USb,<br />

LAN interface and large colour screen.<br />

> NEW<br />

Hioki 9725 Memory Viewer Software<br />

HIO,9725 AU<br />

Data processing software for Hioki 8860 High Speed Memory Recorder.<br />

Functions: file loading, maximum loadable data size 2GW file saving,<br />

measurement of data binary, partial saving between A/b cursors is possible.<br />

Screen images BMP and PNG, calculation results. Display of saved<br />

binary files, displayable channels per sheet analog 32, logic 16 channels.<br />

Displayable sheets 16.<br />

> NEW<br />

Hioki 8938 FFT Input Signal Module<br />

HIO,8938 AU<br />

FFT Module with anti-aliasing filter. Frequency range dc to 400kHz, sampling<br />

rate 1MS/s. Maximum input voltage 400Vdc, 240Vrms.<br />

Hioki 8810 4 Channel Memory Recorders<br />

HIO,8810 AU<br />

4 functions: memory x-T, continuous x-T, memory x-Y, continuous x-Y. 3<br />

channel x-Y is possible. Input amplifier bandwidth 0~100 kHz limited by<br />

max sampling rate of 4µs in memory mode and 100~200µs in continuous<br />

modes. Memory size per channel 8k with 8 bit resolution. paper 110mm<br />

x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in<br />

memory mode giving 32ms~1,600s display. Continuous mode chart speed<br />

1s/div~50min/div in 12 steps. Input floating 10mV/div~5V/div in 12 steps<br />

with fs offset. Internal trigger with level control. External trigger TTL or<br />

contact closure. Successive transient recording possible. Multiple recorder<br />

synchronization possible.<br />

Hioki 8811 3 Analogue 8 Digital Channel Memory Recorders<br />

HIO,8811 AU/MY<br />

Four functions, memory x-T, continuous x-T, memory x-Y & continuous x-Y.<br />

Three channel x-Y is possible. Input amplifier bandwidth 0~100kHz limited<br />

by max sampling rate of 4µs in memory mode and 100~200µs in continuous<br />

mode. Memory size per channel 8k with 8 bit resolution. paper 110mm<br />

x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in<br />

memory mode giving 32ms~1,600s display. Continuous mode chart speed<br />

1s~50min/div in 12 steps. Input floating 10mV~5V/div in 12 steps with<br />

full scale offset. Internal trigger with level control. External trigger TTL or<br />

contact closure. Successive transient recording possible. Multiple recorder<br />

synchronization possible. Hioki 9306 and 9307 probes optional.<br />

Hioki 8835 4 Channel Waveform & 16 Channel Memory<br />

Recorder<br />

HIO,8835 AU<br />

Memory 12 bits x 100k per channel or 500k for a single channel. Analog<br />

input channel ranges 10mV~50V/div, 10x div, 400Vdc, 240Vac rms max.<br />

In-built FDD and type-III pC card slot. Fastest sampling rate 1MHz. paper<br />

110mm x 30m. Colour TFT display. Additional functions include waveform<br />

parameter calculation including rms values, area value, rise and fall times.<br />

AC mains operation.<br />

Hioki 8835-01 4 Analogue, 16 Logic Channel Waveform<br />

Recorder<br />

HIO,8835-01 AU<br />

Memory 12 bits x 1 megaword per channel or 4 megaword for a single<br />

channel. Analog input channel ranges 10mV~50V/div, 10x div, 400Vdc,<br />

240Vac rms max. In-built FDD & type-III pC card slot. Fastest sampling<br />

rate 1MHz. paper 110mm x 30m. Colour TFT display. Additional functions<br />

include waveform parameter calculation including rms values, area value,<br />

rise and fall times. AC mains operation. Logic probes must be rented<br />

seperately.<br />

Hioki 8841 8 Analogue, 16 Channel Memory Recorder<br />

HIO,8841 AU/NZ<br />

Memory 12 bits x 4 megawords/ch for 2 analog ch, to 1 megawords/ch for<br />

8ch. In-built FDD, type III pCMCIA card slot (for flashcard & HDD up to<br />

520Mb). Sampling rate of 1MHz max. Functions memory, real time record,<br />

rms, real time/memory, x-Y memory, FFT. Trigger functions level, window<br />

in, window out, voltage drop, rms level, cycle, logic pattern trigger 1,0 or<br />

x (disregard). When using logic channels, logic probes must be rented<br />

seperately. Measurement range 400Vdc, 240V rms, low pass filters 5Hz,<br />

500Hz, 5kHz or 100kHz, input coupling dc, GND, ac. Large 10.4” colour<br />

TFT display for settings and waveform display, wide thermal printer fitted.<br />

On screen help function. All settings and waveforms can be saved to media,<br />

waveforms can be saved as binary, text or bmp files.


Hioki 8842 16 Analogue, 16 Logic Channel Waveform Recorder<br />

HIO,8842 AU<br />

Memory 12 bits x 16 megawords/ch for 2 analogue ch, to 2 megawords/ch<br />

for 16 ch. Analogue input channel ranges 10mV~50V per div, 10x div, 400V<br />

dc, 240V ac rms max. In-built FDD, type III pCMCIA card slot (for flashcard<br />

& HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real<br />

time record, rms, real time/memory, x-Y memory. Trigger functions level,<br />

window in, window out, voltage drop, rms level, cycle, logic pattern trigger<br />

1,0 or x (disregard). When using logic channels, logic probes must be rented<br />

seperately. Measurement range 400V dc, 240V rms, low pass filters 5Hz,<br />

500Hz, 5kHz, or 100kHz, input coupling dc, GND, ac. Large 10.4” colour<br />

TFT display for settings and waveform display, wide thermal printer fitted.<br />

On screen help function. All settings and waveforms can be saved to media,<br />

waveforms can be saved as binary, text or bmp files.<br />

Hioki 9335 Wave Process Software<br />

HIO,9935 AU<br />

Waveform Processor software, displays, converts to CSV, calculates and<br />

prints waveforms with a pC. Review stored binary files from Hioki 8835,<br />

8835-01, 8841 and 8842 memory recorders. Only way stored binary files<br />

can be viewed on a PC without having to re save them with memory recorder<br />

as Text files.<br />

Hioki 9305 Trigger Cord for Hioki Memory Recorders<br />

HIO,9305 AU<br />

Plug each end of cable 3.5mm. Trigger cord enables master slaving of the<br />

Hioki 8835, 8810 and 8811 memory recorders. One end connected to the<br />

trigger output socket of master recorder the other end connects to the trigger<br />

input socket of the second recorder which is the slave. Trigger pattern set up<br />

for the master and the slave recorder set just to external trigger.<br />

Hioki 4 Channel Digital Probe for use with HIO,8835<br />

HIO,9306 AU<br />

Contact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory<br />

recorders. Threshold digital >1.4V maximum input 50V. Contact closure<br />

input, 2kΩ input resistance 30V allowable input. Response time 2µs.<br />

Hioki 9320 4 Channel Contact & Digital Logic Probe<br />

HIO,9320 AU<br />

For HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders, 4 channels<br />

per probe, max of 4 probes per recorder. Use in conjunction with 9321 line<br />

logic probe. Threshold digital selectable 1.4V, 2.5V & 4V. Response time<br />

500ns max. Relay dry contact detection. Max allowable input 50Vdc.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

memOry recOrderS<br />

Hioki 9321 Line Logic Probe<br />

HIO,9321 AU<br />

Four channels (insulated) per probe. Detection of 60~150Vac, 170~250Vac,<br />

20~150Vdc & 70~250Vdc in 2 ranges. Response time slope rise 1ms, fall<br />

3ms. Max input low range 150V rms, high range 250V rms. Max rated<br />

voltage to earth 250V rms. Connector cable 1.5m. Probe tip cable 1m.<br />

Hioki Kit of Three 9322 High Voltage True rms Interface<br />

HIO,9322-KIT AU<br />

Used with many memory recorders, eg. Hioki 8835. Operating modes 3. DC<br />

mode for waveform monitor output dc to 3MHz, ac mode detection of power<br />

surge noise 1 kHz~10MHz. Rectified true rms output of dc & ac voltages.<br />

40Hz~100kHz response speed 200ms or less. Max voltage dc 2kV, ac 1kV<br />

CATII, ac/dc 600V CATIII, balanced differential input 1/1,000 divider.<br />

Hioki 520Mb PCMCIA Hard Disk for HIO,8835 & 8841<br />

HIO,8835-HD520 AU<br />

Data can be stored as mem file which is binary, data can be replayed on<br />

recorder, txt file which is text so as data can be read using excel, bmp file so<br />

screen dump can be saved for import to word document, single or dual FFT<br />

binary file for playback on recorder. File can be saved as setting file, useful<br />

for customers who rent the memory recorder for same applications again.<br />

Transfer files to a PC and reload next time recorder is rented, saves time<br />

in use of recorders. Card can be plugged in to a pCMCIA Type III slot on a<br />

laptop, files can be stored or viewed.<br />

Hioki 9555 Current Sensor<br />

HIO,9555 AU<br />

For HIO,9278 clamp on CT. Output designed for waveform recording and<br />

depends on CT.<br />

Sandisk Compact Flash Card 512MB with PCMCIA Adaptor<br />

COM,FLASH512Mb AU<br />

Compact Flash Card 512Mb typeI with pCMCIA Adaptor.<br />

Hioki 9278 Universal Clamp-on CT<br />

HIO,9278 AU<br />

For use with HIO,9555. Range 0~200A, dc 100kHz, 20mmØ max jaw.<br />

Hioki 9132 Clip-on ac Current Transducer<br />

HIO,9132 AU/NZ<br />

Ranges 20~1kA fs. Short term overload capability 2kA. Output 0.2Vac. For<br />

use with Hioki 8800 series recorders, for current waveform recording.<br />

Hioki 9018-10 500A ac Clamp-On Transducer<br />

HIO,9018-10 AU<br />

Selectable ranges 10~500A. Output voltage 200mVac fs per range selected.<br />

Up to 3kHz frequency response. bNC connection.<br />

Hioki 3270 Sensor with 150A ac/dc Clamp-On Transducer<br />

HIO,3270-9276 AU<br />

Frequency bandwidth dc to 1MHz, rated output 1.5V for fs of range. Clamp<br />

20mmØ. Suitable to view waveforms with memory recorders.<br />

Hioki 9555 Signal Conditioner with 9278 200A ac/dc Clamp-On<br />

Transducer<br />

HIO,9555-9278 AU<br />

Frequency bandwidth dc to 100kHz, rated output 2V for fs of range. Clamp<br />

20mmØ. Suitable to view waveforms with memory recorders.<br />

Hioki 9304 Input Attenuator for 8800 Series Recorders<br />

HIO,9304 AU/NZ<br />

Max input 600Vdc/ac peak.<br />

DATA ACQUISITION & RECORDING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 75


DATA ACQUISITION & RECORDING<br />

76<br />

Strip chart recOrderS<br />

Yokogawa 3057-22 2 Pen Portable Recorder<br />

YEW,3057-22 AU/NZ<br />

Twelve input ranges 10mV~50V fs, 150mm x 15m Z fold or roll chart, speeds<br />

20mm/h~600mm/min. Accuracy 0.5%. power 240/50Hz, rechargeable<br />

NiCad battery or 12Vdc external.<br />

Yokogawa 3712-31 3 Pen Vertical Chart Recorder<br />

YEW,3712-31 AU<br />

Input ranges dc voltage 10mV~200V fs. Thermocouples including type T<br />

& K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory<br />

card optional.<br />

Yokogawa 3712-41 4 Pen Vertical Chart Recorder<br />

YEW,3712-41 AU<br />

Input ranges: dc voltage 10mV~200V fs. Thermocouples including type T<br />

& K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory<br />

card optional.<br />

Yokogawa 3750 10 Channel Multipoint Recorder<br />

YEW,3750 AU<br />

Ten channel hybrid recorder. Input ranges dc 20mV~20V, thermocouple,<br />

RTD. Scans 10 channels in 2s. AC mains operation.<br />

vOltage current recOrderS<br />

Tech-Rentals CT Terminations for Hioki 8710, etc<br />

<strong>TR</strong>,CT-5 AU<br />

Termination box for 5A output current transformers. For use mainly with<br />

HIO,8710. Comprises quantity 3 shunts 0.04Ω. Output 0.2V @ 5A. Use<br />

with DRA,<strong>TR</strong>2015’s.<br />

Hioki 8206 2 Channel Voltage & Current ac Chart Recorder<br />

HIO,8206 AU<br />

The chart records a true rms. Equivalent reading. AC voltage channel, 3<br />

ranges 50~140V, 100~280V & 250~600V. AC current channel, 0~10, 0~20,<br />

0~50, 0~100, 0~200 & 0~500. Chart speeds 600mm/h~20mm/h. Note the<br />

supplied 9651 clamp-on current probe will measure max 46mmØ conductor.<br />

Frequency range of the clamp 40Hz~1kHz.<br />

tape recOrderS<br />

Teac 16 Channel DAT Instrumentation Recorder<br />

TEA,RD145T AU<br />

Sixteen channel DAT instrumentation/data tape recorder. 4ch~20kHz, 8ch-10kHz, 16ch~5kHz, ac/dc operation. Ch 1 can be selected for analogue or 14-bit<br />

digital. Data recorded at slow speeds can be played back at double speed. Input ranges 0.5, 2, 5 & 20Vp impedance 100kΩ unbalanced output ranges 2~5Vp<br />

variable impedance 75Ω unbalanced. AC or 11~30V dc operation.<br />

plOtter printer<br />

Yokogawa 3750-DC 20 Channel Hybrid Recorder<br />

YEW,3750-DC AU<br />

Input ranges dc 20mV~50V, thermocouple & RTD. Scans 20 channels in 2s.<br />

Operates from 10~32V external dc. RS232C interface option fitted.<br />

Yokogawa 3760 30 Channel Recorder<br />

YEW,3760 AU<br />

Analogue and digital printout. Ten colour with channel identification number.<br />

Scans in 2s. Chart speeds 1~1500mm/h. Inputs dc (20mV~50V range),<br />

thermocouple (R, S, b, K, E, J, T, L, U, N, W, Kp) & RTD. Memory card<br />

reader. Memory card included with several typical set-ups.<br />

Yokogawa DR130 Hybrid 20 Channel Recorder FDD<br />

YEW,DR130 AU<br />

Includes 3.5” FDD. Input unbalanced floating 20mV~50Vdc, TC, RTD and<br />

contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width<br />

150mm. Data can be saved to 500k of internal RAM either directly or due to<br />

alarm conditions. The saved data can be copied to a 3.5” FDD file suitable<br />

for inclusion in standard spreadsheet programmes.<br />

Yokogawa 512K Memory Card for Yokogawa Recorders<br />

YEW,MEM512 AU<br />

Memory card 512k. For YEW,3750, YEW,3760, YEW,3712-31 YEW,3712-<br />

41 and YEW,3701-85 recorders.<br />

Hioki 8710 3 Channel ac/dc Recorder<br />

HIO,8710 AU/NZ<br />

Intended mainly for recording ac line voltage and current. Data is recorded<br />

graphically and printed. Input voltage ranges 70~750V rms ac in 4 ranges<br />

with optimised scale, 0.05~7.5V dc in 5 ranges. AC current ranges using<br />

9008 and 9132 clamp-on probes 10~1000A. Uses type 9221 thermal paper<br />

110mm x 30m. The recorder is suitable for voltage measurements from pAM<br />

thyristor inverters but not all voltage levels with PWM inverters. Chart speed<br />

up to 30 div/min (1div is 9mm). Response time 0.6s.<br />

HP 7440A 8 Pen Plotter<br />

Hp,7440A MY<br />

Media sizes. 210 x 297mm (ISO A4) 8.5 x 11in (ANSI A). Regular plotter paper,glossy presentation paper, fast-dry overhead transparency film. 8 fiber-tip pens,<br />

automatic pen changing & capping. Max plotting area: Y-axis 191mm (7.5in) for A & A4 size paper, x-axis 257mm (10.1in) for A size paper. Resolution:<br />

addressable step size: 0.025mm (0.001 in). pen Velocity: pen up 52 cm/s (20 in/s). pen down max 40 cm/s (16 in/s), programmable 1 to 40 cm/s in 1 cm/s<br />

increments. Acceleration: approx 1.2 g’s. Interface Options: RS-232-C/CCITT V.24 Asynchronous serial, ASCII, 60-byte buffer size.Switch selectable baud<br />

rates: 75~9600. Switch selectable parity: odd, even, or off. HpIb: Switch selectable addresses: 0~31 (31 sets listen-only mode). Size: 308(d) x 460(w) x<br />

125(h)mm. Weight: plotter 4.1kg. power supply 1.4kg.


Model Type<br />

Analog<br />

Out<br />

Druck PTX1400-25 25Bar Pressure Transducer 4-20mA<br />

DRU,pTx1400-25 AU<br />

pressure transducer, 4~20mA output, 0~25 bar (360psi) input. Requires<br />

9~28VDC, supplied with 12V, 500mA power pack.<br />

Druck 580 PSI 40Bar Pressure Transducer 4~20mA<br />

DRU,pTx1400-40 AU<br />

Requires 9~36Vdc, supplied with 12V plug pack.<br />

preSSure & humidity tranSducerS<br />

Pressure<br />

(Bar)<br />

1,000<br />

Differential<br />

Humidity<br />

(%)<br />

ASH,1000<br />

DRU,pTx1400-4 4<br />

DRU,pTx1400-25<br />

DRU,pTx1400-40<br />

4~20mA<br />

25<br />

40<br />

DRU,pTx1400-400<br />

DRU,pTx1400-600<br />

Pressure<br />

400<br />

600<br />

FLU,pV350 42<br />

FLU,pV350-NATA 0~1V 24 Yes<br />

GEM,2200bGb2501A3UA<br />

GEM,2200bGC1001A3UA<br />

4~20mA<br />

25<br />

100<br />

NATA<br />

Operating Temperature<br />

(°C)<br />

KUL,HEM375-5000 High temp pressure 0~100mV 345


PHYSICAL MEASUREMENT<br />

78<br />

diStance meaSurement & Surveying<br />

Digiroll Plus Measuring Wheel & Surveying<br />

DIG,pLUS AU<br />

Measuring wheel. For linear measurement and, area and volume calculation<br />

of construction sites and buildings, etc.<br />

Leica Disto Pro Laser Distance Measurement<br />

LEI,DISTOpRO AU/NZ<br />

Typical accuracy ±1.5mm. Will average over 8 measurements for greater<br />

accuracy. Built in function for height measurement and enclosed angles,etc.<br />

Memory can be divided into groups, e.g. 200 groups with 5 measurements.<br />

Includes PC interface and software, telescope to help find dot in daylight and<br />

bubble level to enable horizontal measurement.<br />

Mitutoyo 500-172 Digimatic Caliper<br />

MIT,500-172 AU<br />

Range 0~200mm (0~8”), resolution 0.01mm (.0005”). Absolute measurement,<br />

LCD display. Temperature operating range 0~40OC, storage temperature -<br />

10~60OC. button settings ON/OFF, inch/mm. Origin, zero/AbS.<br />

Mitutoyo Absolute Digimatic Height Gauge Caliper<br />

MIT,570-314 AU<br />

Digital height gauge for measurement of height of small components/parts.<br />

Functions, origin (absolute origin) setting, AbS (absolute) measurement,<br />

INC (incremental) measurement, hold. Measurement range 24”/600mm,<br />

resolution 0.0005”/0.01mm, error ±0.0020”/0.05mm, display 6 digit LCD.<br />

tachOmeterS/StrObOScOpeS<br />

> NEW<br />

Monarch Palmstrobe Compact Size Portable Stroboscope<br />

MON,pALMS<strong>TR</strong>ObE AU<br />

Compact size portable stroboscope, flash rate from 100~12,500FpM, 6<br />

digit alphanumeric backlit LCD. Tachometer range 5~250,000RpM (only<br />

with external sensor connected, not included). External sensor input TTL<br />

only. Supplied with 2 x removeable rechargeable battery packs, charger<br />

and transit case.<br />

Phantom 53550 Radar Gun kph, with Case and Tuning Fork<br />

pHA,53550 AU<br />

professional doppler K band (24.150GHz) stationary radar gun. Fast action,<br />

pull the trigger and the speed display appears instantly. Unit is invisible to all<br />

radar detectors. power requirements 10.5~16.5Vdc, 13.5Vdc nominal, 1.5A<br />

max, external source, connection via 6’ coiled power cord with fused lighter<br />

plug. Operating environment -20~60ºC, 90%RH @ 37ºC (non-condensing).<br />

Accuracy ±0.17kph. Accuracy verification tuning fork (K-band), internal<br />

90kph. Speed range 17~332kph.<br />

Jenoptik LEM300-GEO Laser Range Finder & Speed Gun<br />

JEN,LEM300-GEO AU<br />

Includes precision inclinometer and compass. Measures up to 300m<br />

horizontal or sloping distances. Distance measurements updated at 50Hz<br />

so accelerations can be analysed via RS232 interface. Overall accuracy<br />

±10cm. Rechargeable batteries.<br />

Hilti PR50 Rotating Laser Level<br />

HIL,pR50 AU<br />

For facade installations, suspended ceilings, excavations, etc. PR50 is a<br />

self leveling rotating laser. System includes tripod and 2 styles of sight, the<br />

first make on audible alarm when the laser is detected, and the second when<br />

detected the system oscillates on to provide good definition of the laser in<br />

high ambient light conditions. Accuracy ±0.7mm in 10m horizontal, ±0.9mm<br />

in 10m vertical. Laser range 30m or more with beam catcher, 150m or more<br />

with laser detector.<br />

Hilti PM10 Multi Directional Laser<br />

HIL,pM10 AU<br />

Triple laser alignment system. Instrument produces 3 visible lasers each at<br />

90O . Supplied with contractors kit including clamps, magnetic bracket, targets<br />

in case. Accuracy ±3mm in 10m, self-leveling from ±4O to horizontal.<br />

> NEW<br />

Monarch PLT200-KIT Digital Contact/Non Contact Tacho<br />

MON,pLT200-KIT AU<br />

Hand held digital contact/non contact tacho kit. Ranges optical/non contact<br />

5~200,000 RpM, contact 0.5~20,000 RpM. Display 5 digits, 5 alpha numeric<br />

LCD. Non contact operating range 90cm, tripod mounting. Direct contact<br />

tips and contact wheel supplied. programmable for IpM, FT/M, YpM, cm/M,<br />

m/M, RpM, RpS, RpH and Totaliser up to 200,000. Output TTL pulse.


Monarch Phaser Strobe Battery Operated<br />

MON,pHASER AU<br />

phaser-stroboscope includes optical and magnetic pickup. Operates from<br />

internal re-chargable batteries or mains. Auto step mode provides slow<br />

motion appearance for high speed repetitive events. Stores and recalls last<br />

3 full settings in memory. Specifications 30~30,000f/min or 0.5~533.33f/<br />

s. Accuracy ±0.01%. Flash rate external triggering 30~9,999.9f/min,<br />

0.5~533.33f/s, 10,000~32,500f/min. phase delay facility.<br />

tachOmeterS/StrObOScOpeS<br />

Hioki 3404 Optical/Contact Tachometer<br />

HIO,3404 AU/NZ<br />

Autoranging 4 digit display. Ranges in RpM mode 30~99.9, 1,000~9,999<br />

& 1,000~9999 x 10. Ranges in RpS mode 0.5~99.99, 100~999.9 &<br />

1,000~1,600. Analogue output 1mV/10RpM or 1mV/100RpM, accuracy 4%.<br />

Tripod mounting. Internal battery or external ac operation. Contact adaptor<br />

included with cone and peripheral ring.<br />

endOScOpeS<br />

Model Type Diameter mm Length - Metre Articulation<br />

FIb,MTFS15-1000<br />

1.5 1 None<br />

MOR,MSGI-1350<br />

MOR,MSpI-3000<br />

MAC,Fb5-1400A<br />

Fibreoptic endoscope<br />

8<br />

4.3<br />

1.3<br />

3<br />

1.25<br />

Semi rigid<br />

2 way<br />

OLY,IF8C5-30 8 3<br />

OLY,IF11D4-20 11<br />

4 way<br />

OLY,IV6C6-20-ZOOM<br />

6<br />

2<br />

OLY,IV6C5-20 51 2 way<br />

OLY,IV8C6-35 Video endoscope<br />

6 3.5 4 way<br />

OLY,IV8D3-20 8.4 2 4 way<br />

OLY,IpLEx-Mx 6 3 4 way<br />

OLY,CYF-3<br />

SIL,PF136<br />

Fibrescope endoscope<br />

6<br />

9<br />

0.37<br />

1.32<br />

2 way<br />

Semi rigid<br />

AQU,SNAKEEYE Colour video flexible cable 30 9.1 None<br />

WHO,VIpER CAMERA KIT Option for Minispring 51 - Rotating head<br />

WOH,MINISPRING Colour video rigid push rod 22 20 None<br />

WOH,VIS220<br />

WOH,VIS2000<br />

RAD,GATORCAM-25-30<br />

RAD,GATORCAM-25-60<br />

Colour video flexible cable<br />

B&W videoscope and recorder<br />

26<br />

51<br />

25<br />

19.5<br />

30<br />

60<br />

None<br />

Rotating head<br />

None<br />

pEA,FLExI-CAM Colour video pipeline inspection system 15<br />

HEI,TECHNO-6x320<br />

6 320mm<br />

OLY,G100-034-090 55 Borescope<br />

10 340mm<br />

SYK,4-30-ARTHRO 4 180mm<br />

DYO,750 Camera and video processor<br />

Pearpoint Flexi-Cam Pipeline Inspection System<br />

pEA,FLExI-CAM AU/NZ<br />

Compact colour video 25mm colour camera with 3lux sensitivity, (light<br />

source white LED’s) on 15m of fully retracting flexi-rod. Flexi-cam navigates<br />

multiple 90O bends in 32mm pipes and images are displayed on the internal<br />

colour TFT screen. Images can be recorded to an external video recorder<br />

(not supplied). System operates from internal fully rechargeable batteries<br />

which provide up to 5h of continuous use when fully charged. Hand-held<br />

portability. Fully waterproof, manually set focus camera. Inspects pipes<br />

25~100mm.<br />

Radiodetection Gatorcam-25-30 Drain Video Inspection System<br />

RAD,GATORCAM-25-30 AU<br />

Monochrome video scope 30m x 25mmØ. Kit includes video display and<br />

VCR combination and 33kHz sonde capability so the camera location can<br />

be determined using the RAD,RD400pxL. Has fixtures to centre the camera<br />

in larger diameter pipes. Camera includes variable illumination. Length of<br />

cable extended is displayed and comments can be added to the image.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Radiodetection Gatorcam-25-60 Drain Video Inspection System<br />

RAD,GATORCAM-25-60 AU<br />

Monochrome video scope 60m x 25mmØ. Kit includes video display and<br />

VCR combination and 33kHz sonde capability so the camera location can<br />

be determined using the RAD,RD400pxL. Has fixtures to center the camera<br />

in larger diameter pipes. Camera includes variable illumination. Length of<br />

cable extended is displayed and comments can be added to the image.<br />

Wohler Minispring 15m x 22mm B&W Inspection Camera<br />

WOH,MINISpRING AU<br />

Semi rigid push rod 20m long with 22mm colour camera. Waterproof to 15m.<br />

Kit includes a small battery operated display with a video output. Large<br />

display and recorder option.<br />

PHYSICAL MEASUREMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 79


PHYSICAL MEASUREMENT<br />

80<br />

endOScOpeS<br />

> NEW Wohler VIS 220 Visual Inspection System for Pipes<br />

and Drains<br />

WOH,VIS220<br />

Compact colour video pipeline inspection system, 26mm colour camera<br />

with bright white LED’s on 19.5m of flexible push rod with metric marking.<br />

Camera sensitivity 3 Lux, lens f=2.5mm, F=2.0, view angle 120º, waterproof<br />

to 30m water depth. Suitable for insertion in pipes and spaces from 40 to<br />

150mm diameter. The system is supplied with 2 battery packs and an AC<br />

charger/power pack, each battery pack lasts approx 1.5h. Supplied with 5.6”<br />

TFT display with extension cable, video output suitable for video recorder<br />

(not supplied).<br />

Wohler VIS2000 30m x 51mm Steerable Color Camera<br />

WOH,VIS2000 AU<br />

For inspection of ventilation ducts, chimneys, chambers and flue gas<br />

systems, etc. Kit consists of color display with joy stick to control the camera.<br />

Flexible 30m cable on a reel, with non-waterproof, splash resistant, 51mmØ<br />

colour camera with illumination. Accessories included to assist for chimney<br />

inspection: a fixture to allow the camera to be lowered down chimneys, a<br />

guide to centre the camera inside chimney-like spaces and a holder to allow<br />

the camera to look up rather than down.<br />

Wohler Viper Camera Kit for Minispring<br />

WOH,VIpER CAMERA KIT AU<br />

Optional camera with remote control movement of camera for<br />

WOH,MINISPRING. Cannot be used on its own.<br />

Aqua Snakeeye 9m x 25mm Video Inspection<br />

AQU,SNAKEEYE AU/MY<br />

For remote inspection work. Very light and compact. Includes a 127mm<br />

TFT-LCD display & 30mmØ camera including illumination. Various adaptors<br />

are supplied for mounting the camera to, your hand, 457mm with 90O<br />

articulation arm or 9.1m extension cable.<br />

Machida FB5-1400A 4.3mmØ x 1.25m Endoscope<br />

MAC,Fb5-1400A AU<br />

End section steerable in 2 axis, 120O. Instrument is fragile due to the narrow<br />

diameter and lack of a thick protective sheath. Light source included.<br />

Moritex MSGI-1350 1.35m x 8mm Semirigid Endoscope<br />

MOR,MSGI-1350 AU<br />

MOR,MSGS-1350 NZ<br />

Size 8mmØ x 1.35m long. Kit includes a 90O side view adaptor, when used<br />

diameter is then 10.1mm. Includes battery light source. View angle 27O.<br />

Focal length 10mm~infinity. Working temperature 0~60OC. Image 13,000<br />

pixel. Optional video camera available.<br />

Olympus CYF-3 6mm Diameter 37cm long Fiberscope<br />

OLY,CYF-3 AU<br />

Fibrescope 6mm diameter, 37cm long fibrescope, articulation 190 deg up<br />

and 90 deg down. Includes CLK-4 light source. Non metal insertion tube,<br />

synthetic rubber.<br />

Moritex PalmScope Video Capture Device for JPEG & Movie<br />

Clip Recorder Inspection<br />

MOR,pALMSCOpE AU<br />

Digital Video Recorder, image capture and storage. Used in conjunction with<br />

an endoscope, borescope or videoscope the PalmScope is an alternative to a<br />

VCR for onsite inspection applications. Unit records, store video sequences<br />

and full frame resolution jpeg images on supplied 512Mb Compact Flash<br />

Card. View images on built in 6.4” TFT LCD screen. Stores jpeg still images<br />

and or mjpeg movie clips. Signal input video NTSC or pAL, auto-selecting.<br />

Moritex 2C Mount Adaptor<br />

MOR,2CMOUNT AU<br />

2C mount adaptor.<br />

Camera Mount for Moritex Eye Piece<br />

MOR,CAM-MOUNT AU<br />

Mount to allow the connection of a standard camera to a Moritex endoscope.<br />

Adaptors connect to where you would normally add a filter to a camera. Ring<br />

sizes which this can adapt to include 52mm, 49mm ,46mm & 37mm. Sony<br />

Mavica (SNY,MAVICA-FD95) can be used, or check the size of the filter<br />

which is used on the camera.<br />

> NEW<br />

Silverado PF136 Portable Fibrescope<br />

SIL,pF136 AU<br />

portable fibrescope, 9mm diameter, 1320mm working length, gooseneck<br />

semi rigid insertion tube, supplied with 90º side view adaptor mirror. built<br />

in battery compartment for LED light source. Viewing direction 0°, viewing<br />

angle 45º, Depth of view 30mm to 150mm. Side view adaptor viewing<br />

direction 90º, viewing angle 45º, depth of view 30mm to 150mm, tip diameter<br />

10mm.


Olympus IPLEX- MX Portable Industrial Videoscope<br />

OLY,IpLEx-Mx AU<br />

IpLEx Mx battery powered industrial videoscope, lightweight just 4.5kg out<br />

of transit case. 6mmØ, 3m length tungsten insertion tube, articulation 4 way<br />

Up/DOWN/LEFT/RIGHT 120O. Field of view 120O, depth of field 18mm<br />

to infinity, illumination method LED. Brightness adjustment 11 step, long<br />

exposure up to 1sec, zoom electronic linear up to 3x, built in 5.6inch TFT<br />

full colour display, image recording built in, image format JPEG, over 230<br />

images with supplied CF card. powered from either rechargable Li-ion 2x<br />

battery packs (4 hours) or AC adaptor.<br />

Olympus Endoscope/Recorder TV Camera Inspection<br />

OLY,VIDEO AU<br />

Video camera, monitor, VCR and adaptor kit to suit Olympus endoscopes.<br />

Two mount adaptor.<br />

Olympus IF8C5-30 8mm x 3m Long Endoscope<br />

OLY,IF8C5-30 AU<br />

Length 3.25m (effective 3m), 8mmØ, angulation range, 4 direction, up/down<br />

120O, right/left 100O, light guide cable length 2m. Optical adaptor fitted<br />

AT60DFF, field of view 60O, forward viewing, depth of field 20mm~infinity.<br />

Outer diameter 8.4mm. Operating temperature in air -10~80OC, in water<br />

10~30OC. Operating pressure water 1,013~1,317hpa (1~1.3atm), air<br />

1,013hpa (1-1.3atm). Fluid resistance insertion tube withstands machine<br />

oil, light oil. Only insertion tube can be placed in water. Supplied with eye<br />

piece and light source.<br />

Olympus IF11D4-20 11.3mm x 2m Length Endoscope<br />

OLY,IF11D4-20 AU<br />

Working length 1.7m. Large sharp images with adjustable focus regardless<br />

of distance. Depth of field of view 8mm~infinity, field of view 78O, direction<br />

of view forward. Easy up/ down 120O, right/left 100O angulation of bending<br />

section which can be locked at any angle. Includes Olympus ILK-5 light<br />

source, halogen lamp. Operating temperature insertion tube including<br />

optical adaptor, in air -10~80OC, in water 10~30OC.<br />

Olympus IV6C6-20-ZOOM Videoscope 6mm x 2m Long<br />

OLY,IV6C6-20-ZOOM AU<br />

Fitted with AT120D/NF optical adaptor, field of view 120O, direction of view<br />

forward, depth of field 5mm~infinity. Angulation 4 way, 150O up/down &<br />

left/right, heavy duty tungsten insertion braid tube. Operating temperature<br />

for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance for<br />

insertion tube - withstand machine oil, light oil and 5% salt water. Supplied<br />

with IV-6A video control unit, which has zooming and virtual scrolling<br />

(panning) with moving images function, extended exposure time for darker<br />

areas, built in image enhancement and freeze frame. ILH-2b light source,<br />

panasonic 7” LCD colour monitor mounted on extension arm all fitted to<br />

transit case for ease of use. Video VHS recorder also included in package.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

endOScOpeS<br />

Olympus IV8D3-20 8.4mmØ, 2m Long Videoscope<br />

OLY,IV8D3-20 AU<br />

Industrial flexible videoscope, 2m long, 8.4mmØ, distal tip non removeable,<br />

field of view 100O, depth of field 7-122mm (fixed focal point). Angulation 4<br />

way, 120O Up/DOWN, 100O RIGHT /LEFT. Heavy duty tungsten insertion<br />

braid tube. Operating temperature for insertion tube in air 0~50OC, in water<br />

10~30 OC. Liquid resistance for insertion tube - withstand machine oil, light<br />

oil and 5% salt water. Supplied with IV-5 video processor unit, ILK-5 light<br />

source and TV/Video VHS recorder.<br />

Olympus IV8C6-35 Videoscope 8.4mm x 3.5m Long<br />

OLY,IV8C6-35 AU<br />

Fitted with AT80D/FF optical adaptor, field of view 80O , direction of view<br />

forward, depth of field 40mm to infinity. Angulation 4 way, 150O in up/down<br />

& left/right, heavy duty tungsten insertion braid tube. Operating temperature<br />

for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance<br />

for insertion tube - withstand machine oil, light oil and 5% salt water.<br />

Supplied with IV-6 video control unit, ILH-2A light source and TV/Video VHS<br />

recorder.<br />

Dyonics Model 750 Video Camera & Processor<br />

DYO,750 AU<br />

For endoscopes and borescopes with british standard eye piece. TV/Video<br />

recorder not included.<br />

Heine Techno 6mm x 320mm T.05.26.302 Borescope<br />

HEI,TECHNO-6x320 AU<br />

Direction of view 70O , with angled extension tube 120O x 120O . battery pack<br />

included, dc supply cord, battery charger and mains power pack.<br />

Olympus G100-034 090 55 Borescope<br />

OLY,G100-034-090 55 AU<br />

G series rigid borescope 340 mm, 10 mmØ, direction of view 90O, field of<br />

view 55O. Stainless steel insertion tube, operating temperature -20~150OC.<br />

Includes Olympus ILK-5 cold light source, Sony CCD-IRIS colour video<br />

camera, AK2-10C adaptor for Sony CCD-IRIS. View via eye piece or via<br />

video connection to TV.<br />

Stryker Borescope 4 mmx 180 mm Long, 27.5O View<br />

SYK,4-30-ARTHRO AU<br />

Supplied with Quantum 4,000 light source, 597 camera head and video<br />

processing unit. Very high quality system.<br />

Fibrescope MTFS15-1000 1.5mm x 1m Endoscope<br />

FIb,MTFS15-1000 AU<br />

Working length 1.5mmØ x 1,000mm. Includes light source. Operating<br />

temperature -20~60OC at atmospheric pressure.<br />

PHYSICAL MEASUREMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 81


PHYSICAL MEASUREMENT<br />

82<br />

micrOScOpeS<br />

Olympus CH2 Binocular Microscope<br />

OLY,CH2 AU<br />

Magnification of eyepiece x 10. Magnification of objective lens x4, x10, x40,<br />

x100 (oil type) to give a max magnification of 1,000. In-built light source.<br />

Proscope SCA-12770 Video Microscope Kit<br />

pRO,SCA-12770 AU<br />

Hand-held USb video microscope complete kit. Includes 200x, 100x, 50x,<br />

1~10x interchangeable lenses, C Mount adaptor, stand and carry case.<br />

Connects to a pC via USb interface. Software allows snap shot still images<br />

and real time movie files to be saved. Resolution is 640 x 480 pixels.<br />

high Speed videO<br />

Redlake Motionmeter High Speed Digital Camera<br />

RED,MOTIONMETER AU/NZ<br />

Up to 1,000frames/s, selectable 50, 60, 125, 250, 500 & 1,000frame/s,<br />

exposure rates 1x, 2x, 3x, 4x, 5x, 10x & 20x the recording rate. Manual<br />

record, trigger record, adjustable pre trigger 0~100%. Storage 4,098 frames.<br />

playback rates 1,2,3,4,5,10,15,25,30,50, 60,125,250,500 & 1000frame/s.<br />

Output composite video NTSC or pAL (monochrome) also supplied with<br />

video to USb converter, flood lights and tripod.<br />

preSSure vacuum gaugeS/recOrderS<br />

Chroma 7310 Video Microscope<br />

CHR,7310 AU<br />

High resolution colour camera x40 & x200 magnification. Includes<br />

illumination, auto gain control, auto white balance adjustment, etc. Freeze<br />

picture and compare function.<br />

Scalar VL-7EX Video Microscope<br />

SCA,VL-7Ex NZ<br />

Handheld video microscope. View and capture images to a pC or TV/video<br />

recorder. Supplied with a x30 lens, video to USb adaptor and windows<br />

software. Optional 14” TV/video is available.<br />

Polaroid Microcam Microscope Camera<br />

pOL,MICROCAM AU<br />

Instant film camera for binocular microscopes. Simple over eyepiece fitting<br />

permits use with virtually any model.<br />

Redlake Motionscope SR500 High Speed Video<br />

RED,SR500 AU<br />

Triggering facilities similar to a digital oscilloscope. 2,048 frames can be<br />

captured up to 500frames/s. Shutter speeds 1/60~1/5,000s. Images can be<br />

viewed from a frame by frame basis to real time. Monochrome image. pAL<br />

video output. TTL trigger input. Use any standard oscilloscope to supply the<br />

signal. C mount interface on camera. System with C mount adaptor can be<br />

used with endoscope.<br />

Redlake 1000 Frames/Sec Motion Scope<br />

RED,S1000 AU<br />

Triggering facilities similar to a digital oscilloscope. 4,096 frames can be<br />

captured at up to 1,000frames/sec. Images can be viewed from a frame<br />

by frame basis to real time. Shutter speeds 1/60~1/10,000s. Monochrome<br />

image 336 x 243 x 8-bit pixels. Weight 5.5kg. pAL video output. Trigger<br />

input TTL. Use any standard oscilloscope to supply the signal. Adaptor can<br />

be used with endoscope.<br />

Orion VPDC ac/dc Powered Video Recorder<br />

ORI,VpDC AU<br />

pAL b/G portable video recorder includes NTSC playback on pAL TV. Two<br />

rotary heads, helical scanning system, 1 track audio.<br />

Orion 10VRKT 23cm TV with built in VCR<br />

ORI,10VRKT AU<br />

AC/dc combination 10” (23cm) colour TV and video recorder. TV channels<br />

VHF, UHF, audio output power 1.2W max. VCR pAL b/G, 2 head. power<br />

240Vac, 12Vdc. Supplied with remote control.<br />

Model Type Pressure (Bar) NATA Accuracy<br />

bRI,1000-NATA<br />

69<br />

bRI,10000-NATA Pressure recorder<br />

690<br />

Yes 0.5%<br />

bRI,5000-NATA 345<br />

HOB,PRES Pressure logger 1.013 1% fs<br />

STE,1000-NATA<br />

69<br />

STE,10000-NATA<br />

STE,5000-NATA<br />

Pressure gauge<br />

690<br />

345<br />

Yes 0.5%<br />

<strong>TR</strong>,pRESS-NATA 100<br />

CEC,140bAR<br />

CEC,30bAR<br />

Digital gauge & logger<br />

140<br />

30<br />

No ±0.1%


Tech-Rentals 4,000, 6,000 & 10,000kPa Pressure Gauges NATA<br />

Calibrated<br />

<strong>TR</strong>,pRESS-NATA AU<br />

Three gauges. Accuracy ±0.5% 4,000kpa, 6,000kpa & 10,000kpa.<br />

Bristol Babcock 1,000psi Mech Chart Recorder<br />

bRI,1000-NATA AU<br />

Circular pressure chart recorder 1,000psi. 12”Ø. Accuracy ±0.5% NATA<br />

calibrated. Fitted with 2 speed spring wound chart drive giving 7d or 24h<br />

recording. pressure connection ¼”NpT.<br />

Bristol Babcock 5,000PSI Mech Chart Recorder<br />

bRI,5000-NATA AU<br />

Circular pressure chart recorder 5,000psi. Description as above<br />

Bristol Babcock 10,000 PSI Mech Chart Recorder<br />

bRI,10000-NATA AU<br />

Circular pressure chart recorder 10,000psi. Description as above.<br />

Stewart Buchanan 12 1,000 PSI Gauge NATA<br />

STE,1000-NATA AU<br />

Stainless steel, accuracy ±0.5% NATA calibrated. pressure connection<br />

¼”NpT.<br />

Endress & Hauser 4Bar Transducer<br />

E&H,pMp-4bAR NZ<br />

Description as per E&H,pMp-1bar<br />

Endress & Hauser 40Bar Transducer<br />

E&H,pMp-40bAR NZ<br />

Description as per E&H,pMp-1bAR<br />

Endress & Hauser 100Bar Transducer<br />

E&H,pMp-100bAR NZ<br />

Description as per E&H,pMp-1bAR<br />

Jumo 1030 10Bar Pressure Transducer<br />

JUM,1030-0-10bAR NZ<br />

Output 4~20mA. Accuracy is 0.5%. Temperature range -40~85ºC, response<br />

time 30ms.<br />

Jumo 40Bar Pressure Transducer<br />

JUM,40bAR NZ<br />

Output 4~20mA. Accuracy 0.5%. Temperature range -40~85ºC, response<br />

time 30ms.<br />

Schaevitz P3061-4D 4PSI Differential Pressure Transducer<br />

SHA,p3061-4D AU<br />

100” water gauge, 4psi. LVDT type with built-in amplifier. Output 0~5Vdc.<br />

Operates from 10~32Vdc or ac mains.<br />

Kulite 5,000PSI High Pressure Temperature Transducer 260OC<br />

KUL,HEM375-5000 AU<br />

Includes 10V regulated supply. Output 0.020mV/psi.<br />

Trafag 8891 4Bar/58PSI, 0~10V, Pressure Transducer<br />

<strong>TR</strong>A,8891-4-10V AU<br />

Accuracy ±0.3% FS. Overpressure 10bar (145psi). Output 0~10V. pressure<br />

connection G ¼” male. bandwidth 1kHz. Media temperature 125OC. IP65<br />

rated. power supply 15~30V.<br />

Trafag 8891 4Bar, 58 PSI, 4~20 mA, Pressure Transducer<br />

<strong>TR</strong>A,8891-4-20A AU<br />

Accuracy ±0.3% FS. Overpressure 10bar (145psi). Output 4~20mA.<br />

pressure connection G ¼” male. bandwidth 1kHz. Media temperature<br />

125OC. Ip65 rated. power supply 10~30V.<br />

Trafag 8204 1Bar ,14PSI, 4~20mA, Differential Pressure<br />

Transducer<br />

<strong>TR</strong>A,8204-1D-20A AU<br />

Same specification as above.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

preSSure vacuum gaugeS/recOrderS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Stewart Buchanan 12 5,000 PSI Gauge NATA<br />

STE,5000-NATA AU<br />

Stainless steel, accuracy ±0.5% NATA calibrated. pressure connection<br />

¼”NpT.<br />

Stewart Buchanan 12 10,000 PSI Gauge NATA<br />

STE,10000-NATA AU<br />

Stainless steel, accuracy ±0.5% NATA calibrated. pressure connection<br />

¼”NpT.<br />

XP2i Digital Gauge & Logger 140Bar<br />

CEC,140bAR NZ<br />

Intrinsically safe high accuracy temperature compensated pressure data<br />

logger with IANZ calibration certificate. Records up to 3,000 pressure<br />

measurements. Recording intervals or 1s~8h. Data download and analysis<br />

on any Windows equipped laptop or PC. Data can be saved directly into MS<br />

Excel. Internal battery powers unit up to 3m. Can be used as a reference<br />

gauge with or without a hand pump.<br />

XP2i Digital Gauge & Logger 30Bar<br />

CEC,30bAR NZ<br />

Description as above.<br />

preSSure & humidity tranSducerS<br />

Vega Bar 20 0~1Bar Transducer with Display<br />

VEG,bAR20-1 AU<br />

Output 4~20mA. LCD display and is rated Ip65. Over pressure resistant<br />

to 10bar & -1bar. Measurement accuracy 0.5%, linearity deviation 0.085%.<br />

May be set to bar, psi, kpa, mpa, mmH O, mH O & mbar. Output can be<br />

2 2<br />

4~20mA or 20~4mA. Integration time 0~10s. Density factor may be entered<br />

for mm & m, output simulation indication module has 20 segment bar graph<br />

and 4 digit display which may be scaled (has factory default reset). Supply<br />

required 12~36Vdc.<br />

Schaevitz P53363 500 PSI, 0~5V Pressure Transducer incl<br />

Snubber<br />

SHA,p53363-500 AU<br />

Output 0~5V.<br />

Schaevitz P1241 500PSI Pressure Transducer<br />

SHA,p1241-500 AU<br />

Output 0~5 V. port ¼”bSp (f). Operation12Vdc or mains.<br />

Fluke PV350 Vacuum/Pressure Indicator<br />

FLU,pV350 AU<br />

Can be used with a digital multimeter (eg Metrix Mx45) to act as an indicator.<br />

Range, pressure to 600psi (4137kpa) & vacuum 0~29.22”Hg (0~76cmHg ).<br />

Results in either psi or kpa. Connector ½”NpT (m). Cable 2.4m provided.<br />

Battery powered.<br />

Fluke PV350 Vacuum/Pressure Indicator, NATA Certificate<br />

FLU,pV350-NATA AU<br />

Specification as above but with NATA certificate.<br />

Schaevitz P1241 10,000PSI 0~5V Pressure Transducer incl<br />

Snubber<br />

SHA,p1241-10000 AU<br />

pressure transducer 10,000psi, includes snubber, 0~5V output.<br />

Ashcroft 1,000 Bar Pressure Transducer<br />

ASH,1000 AU<br />

Range 10~36Vdc supply. Output 4~20mA. Connection ¼”NpT (M).<br />

GEM,2200BGC001A3UA 100Bar Pressure Transducer<br />

GEM,2200bGC1001A3UA AU<br />

Can be used with a digital multimeter (eg Metrix Mx45) to act as an<br />

indicator. Transducer could be used with a chart recorder or data logger that<br />

can accept 4~20mA signal input. pressure range is 100bar (10,000Kpa or<br />

1,450psi). Transducer has a 4~20mA output. power supply and connection<br />

leads are supplied.<br />

PHYSICAL MEASUREMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 83


PHYSICAL MEASUREMENT<br />

84<br />

preSSure & humidity tranSducerS<br />

Rotronic Temperature/Humidity Transducer for DataTaker<br />

DT600/605<br />

ROT,HTO45R001V AU<br />

Humidity range 25~90%RH 10mV/%RH accuracy 3% resolution 0.6%.<br />

Temperature range 5~50OC, 10mV/1OC accuracy 1O, rep 0.2OC. Datataker<br />

will supply around 100mA through switched supply. Response time 10s<br />

humidity, 20s temperature. Duct mount model 120mm long x 25mmØ.<br />

Supply 4.8~24Vdc draws 4mA.<br />

pOSitiOn tranSducerS<br />

Houston 1850-40 Position Transducers<br />

HOU,1850-40 AU/NZ<br />

Linearity 0.1% travel 40” (1m). Cable tension 280g. Max velocity 132cm/s.<br />

Output is a variable resistance arranged to provide both high level (V) and<br />

low level (mV) outputs when powered from an external source.<br />

inclinOmeterS<br />

Vaisala HMP 235Y 180OC Humidity Probe<br />

VAI,HMp-235Y AU<br />

High temperature humidity and temperature transmitter. Sensor head<br />

operates from 0~180 O C. Measurement range 0~100%RH. Accuracy of<br />

1%RH at 20 O C. Output 0~5Vdc. Other outputs easily set including 4~20mA.<br />

Operates from 15~30Vdc or ac mains.<br />

Vaisala HMP 135Y 160OC Humidity Probe<br />

VAI,HMp-135Y AU<br />

Same specification as above but sensor head operates from 0~160OC.<br />

Unimeasure P510-40 Position Transducer<br />

UNI,p510-40 AU<br />

Travel 40” (1m). Output 0~5V or 0~10V selectable. Requires 12~30Vdc<br />

source.<br />

Wyler Clinitronic 45 Inclinometer RS-232C<br />

WYL,CL45 AU/MY<br />

Resolution 0.01O. Accuracy better than 30arc sec. Display inclination in all common measurements. Includes RS232 interface for remote display of<br />

inclination and also logging. Settling time


lOad cellS<br />

Model Type Range (kg) Output (V)<br />

bAR,MTC-150<br />

bAR,STC-500 230<br />

bAR,STC-500NATA 230g<br />

bAR,STC-4400 Load cell<br />

2,000<br />

68 0~5<br />

AIC,SG-AST-500 500 0~10<br />

bAR,STC-5000 2,270<br />

bAR,STC-10000 4,536<br />

bAR,STC-20000 9,072<br />

bAR,STC-25000 12,000<br />

EMC,100KG<br />

EMC,200KG Tension load cell<br />

200 Yes<br />

EMC,1000KG 1000 Yes<br />

S<strong>TR</strong>,1590C Compression load cell 8,000<br />

DIL,ED2000R<br />

20,000<br />

Crane scale<br />

DIL,Ex2000 – 5K 5,000<br />

AND,WEIGH-bEAMS Platform Scale 2,000<br />

AND Mercury Platform Weighbeams for Pallet up to 2,000kg<br />

AND,WEIGH-bEAMS AU<br />

Total weight capacity 2,000kg for the 2 weigh beams. Two stainless steel<br />

weigh beams supplied, length 1200l x 100w x 80hmm, weight 13kg each.<br />

Connection cable length 5m. AD4406 display supplied, RS232 output.<br />

Transit case with handles and wheels for ease of handling.<br />

Barlo MTC-150 150lb/68kg Load Cell<br />

bAR,MTC-150 AU<br />

Range 68kg compression and tension. Complete with interface operating<br />

from 12Vdc or ac mains giving 0~5Vdc output.<br />

AIC SG-AST-500 500kg S Type Load Cell with Panel Display<br />

AIC,SG-AST-500 AU<br />

Tension and compression 500kg. Nominal output 2mV/V, max excitation<br />

15Vdc, Ip67 protection, safe load 125%, compensated temperature range<br />

-10~40OC. Thread M12 x 1.75p. Supplied with 2 x detachable rod end<br />

bearings, pM4 -SG-dc-5E load cell panel meter, power 12~48V dc, ac<br />

adaptor supplied, output 0~10V. panel indication in kg.<br />

Barlo STC-500 500lb/230kg Load Cell<br />

bAR,STC-500 AU<br />

Complete with conditioning electronics. Output 0~2V. Uses ½”UNF thread.<br />

Barlo STC-500 500lb/230kg Load Cell NATA Calibrated<br />

bAR,STC-500NATA AU<br />

Specification as above but with NATA calibration. This load cell is suitable<br />

for tension only.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

100<br />

0~2<br />

0~5<br />

RS232/485<br />

Barlo STC-4000 4,400lb/2,000kg Load Cell<br />

bAR,STC-4400 AU<br />

Range 2,000kg compression and tension. Complete with series interface<br />

operating from 12Vdc or ac mains. Output 0~5Vdc. Cable to digital display<br />

unit 6m. Uses ¾”UNF thread.<br />

Barlo STC-5000 5,000lb/2,270 kg Load Cell<br />

bAR,STC-5000 AU<br />

Range 2,270kg compression and tension. Interface operates from 12Vdc or<br />

ac mains. Output 0~5Vdc. Display resolution 1kg.<br />

Barlo STC-10000 10,000lbs/5,000kg Load Cell<br />

bAR,STC-10000 AU<br />

Range 4,536kg compression and tension. Interface operates from 12Vdc or<br />

ac mains. Output 0~5Vdc.<br />

Barlo STC-20000 20,000lb/10,000kg Load Cell<br />

bAR,STC-20000 AU<br />

Range 9,072kg compression and tension. Interface operates from 12Vdc or<br />

ac mains. Output 0~5Vdc.<br />

Barlo 25,000 lb/12,000 kg Load Cell and Display<br />

bAR,STC-25000 AU<br />

Complete with 10m cable. Includes D shackles, analog and RS232 output.<br />

12,000kg load capacity.<br />

PHYSICAL MEASUREMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 85


PHYSICAL MEASUREMENT<br />

86<br />

lOad cellS<br />

EMC 100kg Tension Load Cell<br />

EMC,100KG NZ<br />

100kg S type tension load cell with digital indicator. Accuracy ±0.3% of<br />

reading. Operating temperature range -18~65ºC. Safe overload is 150% of<br />

rated capacity. Supplied with threaded eye hooks. Analogue output.<br />

EMC 200kg Tension Load Cell<br />

EMC,200KG NZ<br />

200kg S type tension load cell with digital indicator. Specification as per<br />

EMC,100kg<br />

EMC 1000kg Tension Load Cell<br />

EMC,1000KG NZ<br />

1,000kg S type tension load cell with digital indicator. Specification as per<br />

EMC,100kg<br />

EMC Load Cell Conditioner<br />

EMC.L/CELL-COND NZ<br />

Load cell conditioning unit with a recorder output. AC mains powered.<br />

Strainstall 8,000kg Compression Load Cell<br />

S<strong>TR</strong>,1590C NZ<br />

8,000 kg compression pedestal load cell.<br />

Dillon ED2000 Crane Scale 20,000kg with Radio Remote<br />

Control<br />

DIL,ED2000R AU<br />

Complete with shackles and radio remote control unit. Range 20,000kg.<br />

Accuracy 0.1%, i.e. 20kg uncertainty. Units of measure kg, kt, mt, & lb.<br />

Resolution 5kg. proof load 200% of rated load. Displays gross and net force.<br />

RS232 and RS485 data outputs. Continuous measurement and peak hold.<br />

materialS teSting<br />

> NEW<br />

Anton Paar DMA 35N Portable Density Meter<br />

pAA,DMA35N<br />

Portable density, specific gravity & concentration meter. Measuring range<br />

0.000~1.999g/cc and 0.0~40.0ºC. built-in pipette style pump for sample<br />

aspiration, with port for optional syringe-filling. Display of specific gravity,<br />

ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically<br />

safe [ATEx] for use with batteries, petrochemicals and solvents. Data<br />

storage of up to 1024 results, with recall, and infrared port for RS232<br />

download to serial printer or PC. Wetted parts glass and PTFE. Battery<br />

powered.<br />

Dillion ED2000 5,000 kg Crane Scale<br />

DIL,ED2000-5K AU<br />

Complete with shackles. Range 5,000kg. Accuracy 0.1%. Resolution 1kg.<br />

i.e. 20kg uncertainty. Units of measure: kg, kt, mt, & lb. proof load 200%<br />

of rated load. Displays gross and net force. Continuous measurement and<br />

peak hold.<br />

UWE 5,000kg Digital Crane Scale<br />

UWE,CS-5T NZ<br />

battery powered digital crane scale complete with hook & shackle. Load<br />

capacity 40kg~5,000kg, resolution 2, accuracy is ±10kg. built in large LED<br />

display, wireless remote control, and charger.<br />

Hydramotion Viscolite 700 Portable Viscometer<br />

HYL,V700S-21 AU<br />

Advanced portable viscometer with stainless-steel probe. Operating range<br />

0.1~10,000mpaps (cp) with integral temperature correction -40~150ºC.<br />

probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm<br />

(viscosity/temperature). Acetal polymer probe base for handheld or clamped<br />

operation, with coiled-cable connection to meter unit with 5 digit display.<br />

Battery powered.


Model Type RS232 Range (g) Resolution (g)<br />

AND,GR-202 Analytical balance Yes 210 or 42 0.1mg or 0.01mg<br />

AND,FC-10K<br />

10kg 0.02<br />

AND,HF-300G Yes 310 0.001<br />

AND,Hp-40KA 20kg 0.5<br />

Counting scale<br />

MET,PB8000I 8.1kg 100mg<br />

ISH,CCS3025 25kg 5mg<br />

OHA,Exp4100<br />

4,100 0.01<br />

AND,AD4714<br />

70 0.01<br />

Moisture balance<br />

Yes<br />

AND,Mx50 51 0.001<br />

AND,FG-150Kb Platform scale 150kg 0.05<br />

AND,HL400 Scale 400 0.1<br />

AND,FS-15KA<br />

15kg 1<br />

Weighing Scales<br />

MET,15KG 15kg<br />

MET,60KG 60kg<br />

AND,WEIGHbEAMS Platform Scale Yes 2000 0.05<br />

A&D Mercury Platform Weighbeams for Pallet up to 2000kg<br />

AND,WEIGH-bEAMS AU<br />

For pallet weighing. Total weight capacity 2000kg for the two weigh beams.<br />

Two stainless steel weigh beams supplied, length 1200mm, width 100mm,<br />

height approximate 80mm, weight of each beam 13kg. Connection cable<br />

length 5 metres. AD4406 display supplied, RS232 output. Transit case with<br />

handles and wheels for ease of handling.<br />

A&D Mercury AD4714 Moisture Balance Scales<br />

AND,AD4714 AU<br />

Moisture content to 0.1%. Sample weight 5~70g. Includes timer and RS232<br />

interface. Weight readability 0.01g. Max temperature 200ºC, heater 185W<br />

infrared.<br />

Ohaus EXP4100 4100g Balance and Counting Scale<br />

OHA,Exp4100 AU<br />

Capacity 4.1kg. Display resolution 0.01g. Multi-unit display. Repeatability<br />

0.005g. RS232 interface.<br />

A&D Mercury FS-15kg Weighing Scales<br />

AND,FS-15KA AU<br />

High resolution 15kg scales. Display resolution 1g. AC & NiCad battery<br />

operation.<br />

A&D Mercury FC-10K Counting Scales<br />

AND,FC-10K AU<br />

High resolution 10kg scales with sample counting facility. Display resolution<br />

1g, internal resolution 0.02g. Sample size user selectable – normally 10<br />

pieces. Max count size up to 999,999. AC & NiCd battery operation.<br />

A&D HP-40KA 40kg Counting Scale<br />

AND,Hp-40KA AU<br />

Capacity 40kg with 0.5g resolution. Can be used to determine battery weight<br />

change with charge, etc.<br />

A&D Mercury FG-150KB 150kg Scales<br />

AND,FG-150Kb AU<br />

Capacity 150kg, 0.05 resolution. Includes RS232 port. National Standards<br />

Commission approved (NSC).<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

ScaleS & balanceS<br />

A&D HF-300G Mercury 300g Counting Scales<br />

AND,HF-300G AU<br />

Scales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port.<br />

Includes counting software. Can be used as counting scales.<br />

Ishida 25kg Digital Counting Scales<br />

ISH,CCS3025 NZ<br />

Maximum capacity 25kg, resolution 5g. Features: unit weight, sample<br />

weight and tare.<br />

A&D Mercury MX50 Moisture Analyser<br />

AND,Mx50 AU<br />

Maximum sample weight capacity 51g, resolution 0.001g, moisture content<br />

accuracy over 1g, 0.1%, over 5g, 0.02%. ,Halogen lamp heater, 400W<br />

max. Drying temperature 50~200OC. Measurement programs 20 sets,<br />

measurement mode moisture content, wet or dry, dry content, ratio, weight.<br />

Heating mode standard, automatic, quick, timer, manual. Display large VFD,<br />

interface RS232C, CD-ROM software supplied. pan sample size diameter<br />

85mm.<br />

Mettler PB8001 8kg Counting Scales<br />

MET,pb8001 AU<br />

Capacity 8.1kg with 0.1g readability. Sample size selectable 5~100. Can do<br />

taring, percent and dynamic weighing. Powered by battery eliminator.<br />

A&D Mercury HL400 Scale 400g x 0.1g<br />

AND,HL400 AU<br />

battery operated balance, range 400g, resolution 0.1g<br />

A&D GR-202 Mercury Dual Range Analytical Balance<br />

AND,GR-202 AU<br />

Two-layer construction, splash-proof keyboard and front operating doorlever.<br />

Range 210g x 0.1mg & 42g x 0.01mg. One-touch calibration and<br />

automatic self-calibration outside preset temperature limits. Functions<br />

include multiple weighing units, counting or %, data memory, adjustable<br />

environment setting and GLP management. Bidirectional RS232C standard.<br />

Low-voltage operation with ac adaptor.<br />

Mettler 15kg Weighing Scales<br />

MET,15KG MY<br />

Mettler 60kg Weighing Scales<br />

MET,60KG MY<br />

PHYSICAL MEASUREMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 87


NON-DES<strong>TR</strong>UCTIVE TESTING<br />

88<br />

vibratiOn & alignment analySiS<br />

Model Type Application Features<br />

ARL,EL-235 Ground vibration logger<br />

BK,2635 Accelerometer charge amp<br />

Monitoring vibration for<br />

pile driving and general<br />

construction vibration<br />

Logging outdoors<br />

enclosure<br />

bK,4230 Sound level meter calibrator NATA<br />

bK,4333<br />

Frequency<br />

Range<br />

(Hz)<br />

2~10,000<br />

Max<br />

Acceleration (G)<br />

bK,4343<br />

BK,8301<br />

Accelerometer<br />

2~12,000<br />

10,000<br />

bK,4370<br />

0.2~5,4kHz 2,000<br />

bK,4371<br />

Single axis accelerometer<br />

0.2~12.7kHz 20,000<br />

pCb,300A20 Low G will operate down to DC dc~300 20<br />

TEx,ATM<br />

Blast logger and ground vibration<br />

logger<br />

Explosion and general<br />

construction vibration<br />

monitoring<br />

Logging outdoor<br />

enclosure, tri-axial<br />

geophones<br />

bLA,UMx-SM-6 Blast logger Explosion monitoring Tri-axial geophones<br />

CSI,UL<strong>TR</strong>ASpEC Balancing system & vibration analysis Balancing & spectral analysis<br />

LAb,LW-140-141<br />

Vibration table (requires frequency<br />

source)<br />

Shake source for testing<br />

purposes<br />

pRU,ROT<br />

pRU,ROT-UL<strong>TR</strong>A<br />

Optical machinery shaft alignment<br />

Allow for the alignment of non<br />

rotating shafts<br />

RIO,Cp-10 Printer For use with RIO,VA-10<br />

RIO,VA-10<br />

RIO,VA-11<br />

Vibration analyser Machinery condition monitoring<br />

RIO,VM82 Vibration meter Machinery and monitoring<br />

SVA,912A & SVA,SV06A Tri-axial accelerometer & analyser<br />

TIN,SHOCKSET Single axis shock logger<br />

Whole body vibration<br />

measurement<br />

Shipping and packaging<br />

analysis<br />

Includes thermal<br />

growth analysis<br />

Hand held<br />

accelerometer<br />

Hand held & magnetic<br />

accelerometer<br />

PC memory card<br />

capability<br />

Magnetic<br />

accelerometer<br />

Includes whoopee<br />

cushion<br />

Logging capability<br />

4.5~500<br />

PIE,308B Accelerometer with amp 1~3kHz<br />

MAD,SHOCK101 Tri-axial bump Logger<br />

Pruftechnik Rotalign Ultra Laser Shaft Alighment<br />

pRU,ROT-UL<strong>TR</strong>A AU<br />

Laser based rotating shaft alignment system. Maximum separation between<br />

emitter and receiver 10m. Aligns horizontal and vertical machines, aligns<br />

coupled and uncoupled shafts equally well. Ultra modern computer design,<br />

backlit colour display, Intel xScale 400MHz CpU, USb for peripheral devices,<br />

pC, printer, also bluetooth communication. backlit keyboard, rechargeable<br />

Li-Ion battery pack. Machine train alignment- 14 machines. Alignment<br />

results in 3 quick steps, thermal growth computation. Rotalign Ultra Reader<br />

software included.<br />

Logging vibration for<br />

transportation i.e. trucks,<br />

containers<br />

Tri-axial transportation<br />

logging<br />

+/-50


Pruftechnik 1500mm Length Tension Chains<br />

pRU,AL12.116 AU<br />

1500mm length tension chains for pRU,ROT-UL<strong>TR</strong>A.<br />

Pruftechnik Rotalign Shaft Alignment<br />

pRU,ROT AU<br />

Max alignment distance 10m. Aligns horizontal and vertical machines.<br />

Graphical display of alignment condition. Resolution 1micron, angular better<br />

than 10µRad.<br />

Pruftechnik Magnetic Sliding Bracket<br />

pRU,MAG-bRKT AU<br />

Designed to be used with the Rotalign. Used when shafts to be aligned<br />

cannot be rotated. A bracket is required for each non-rotating shaft to be<br />

aligned (ie. usually 2 will be required).<br />

Madgetech Ultrashock-EB Transportation Logger<br />

MAD,UL<strong>TR</strong>ASHOCK-Eb AU<br />

Ambient temperature, humidity, pressure and 3 axis shock acceleration<br />

logger. Ranges: -40~180ºC, 0-95%RH, 0~30pSIA (0-200kpa), -50g~50g.<br />

Memory 23,831 readings per channel. Logging interval from 1 reading per<br />

2s to 1 reading per 12h. Sampling rate 2ms. Includes RS232 interface and<br />

setting up, downloading, graphing software.<br />

Madgetech Shock101-EB <strong>TR</strong>-Axial Transportation Logger<br />

MAD,SHOCK101 NZ<br />

battery powered, stand alone 3-axis shock recorder, extended battery life of<br />

up to 60 days typical. Measures and records shock as the peak acceleration<br />

levels over the user defined interval. Designed for documenting dynamic<br />

environments such as moving vehicles, containers, ships, etc.<br />

Tiny Tag, Set of 6 Loggers: 3 x Shock, 2 x Temperature,<br />

1 x Humidity<br />

TIN,SHOCKSET AU<br />

For shipping and transport testing. Includes 3 x shock loggers; these record<br />

the max G force in the programmed period. Includes a humidity logger,<br />

an internal temperature logger and temperature logger with external probe.<br />

Set also includes an f computer to download and view the results.<br />

Svantek 912A Sound Vibration Analyser<br />

SVA,912A AU<br />

Type 1 sound level meter including a single axis accelerometer. Provides<br />

standard sound measurements and vibration measurements including<br />

1/1 octave, 1/3 octave and full spectrum. Unit will store 1Mb of spectrum<br />

analysis information for waterfall plots etc. PC interface software included.<br />

Unit can make part body vibration measurements. If whole body vibration<br />

measurements are to be made the SVA,SV06A accessory must be used.<br />

Svantek SV06A Tri-axial Accel Interface for 912A<br />

SVA,SV06A AU<br />

Accessory kit for human whole body vibration measurement. provides<br />

4 accelerometer inputs for the SVA,912A and a tri-axial accelerometer<br />

‘whoopee cushion’ for whole body vibration. Can operate as an interface for<br />

a standard b & K tri-axial accelerometer.<br />

PCB Low G Accelerometer dc to 300 Hz<br />

pCb,300A20 AU<br />

Single axis accelerometer includes charge amplifier. Range ±20g,<br />

frequency (±5%) dc~300Hz, (±10%) ~500Hz. Shock limit ±5kg. Operating<br />

temperature -40~85OC. Weight 15g. Voltage sensitivity 100mV/g.<br />

B&K 2635 Charge Amplifier<br />

bK,2635 AU/MY<br />

built-in integrators for displacement and velocity. Sensitivity to 10V/pC.<br />

bandpass filters. Operates also from external 6~28Vdc or ±14Vdc. battery<br />

operated 100h life. Required with accelerometers.<br />

B&K 4333 Accelerometer<br />

bK,4333 MY<br />

Frequency range: 2~10,000Hz. Voltage sensitivity 14~24mV/g. Charge<br />

sensitivity 14-20pc/g. Maximum sinusoidal acceleration 7500g. Maximum<br />

shock 10,000g.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

vibratiOn & alignment analySiS<br />

B&K 4343 Accelerometer<br />

bK,4343 MY<br />

Accelerometer. Frequency range: 2~12,000Hz. Charge sensitivity 10~mV/g.<br />

Charge sensitivity 10pc/g. Maximum shock 10000g.<br />

B&K 4370 Accelerometer<br />

bK,4370 AU<br />

Frequency range 0.2Hz~5.4kHz. Voltage sensitivity 100mV/G or 8mV/ms2<br />

(approximately) into 20GΩ. Charge sensitivity 100pC/G or 10pC/ms2. Max<br />

sinusoidal acceleration 2,000G. Max shock 2,000G. Requires 1 charge<br />

amplifier.<br />

B&K 4371 Accelerometer<br />

bK,4371 AU/MY<br />

Frequency range 0.2Hz~12.7kHz. Voltage sensitivity 10mV/G or 0.8mV/Ms2<br />

(approximately) into 20GΩ. Charge sensitivity 10pC/G or 1pC/MS2. Max<br />

sinusoidal acceleration 6,000G. Max shock 20,000G. Requires 1 charge<br />

amplifier.<br />

B&K 8301 Accelerometer<br />

bK,8301 MY<br />

Accelerometer. Frequency range: 2~12000Hz. Sensitivity 10mV/g. Charge<br />

sensitivity 10pc/g. Maximum shock 10000g.<br />

B&K Vibration Impact Hammer<br />

bK,8202 AU<br />

For determining frequency response functions. Individually calibrated force<br />

transducer. Comes with 3 different tips and additional mass to enable pulse<br />

duration and frequency range to be determined.<br />

Piezotronics Accelerometer and Amplifier<br />

pIE,308b AU<br />

Accelerometer frequency range 1Hz~3kHz ±5%, 0.7Hz~6kHz ±10%,<br />

voltage sensitivity 100mV/g or 10.2mV/m/s2 ±2%. Range: ±50g, ±5V<br />

output, resolution 0.001g, vibration max 500G, shock max 5,000G. Supplied<br />

with pCb482A10 ICp line power unit.<br />

Linear Accelerometer +/-1G dc Response<br />

LIN,LSpC-1 AU<br />

Designed for very low force levels ±1G measurement range. Operates<br />

down to dc in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%.<br />

Shock Survivability 100g. Natural Frequency 100Hz.<br />

Rion VM82 Vibration Meter<br />

RIO,VM82 NZ<br />

Single axis. Measure acceleration from 0.02~200m/s2. Velocity from<br />

0.1mm~1m/s rms. Displacement from 0.001~100mm. AC/dc output of 1V<br />

full scale.<br />

Rion VA-10 Vibration Analyser<br />

RIO,VA-10 AU/MY<br />

Vibration analyser for rotating machinery. Measures acceleration, velocity<br />

and displacement. Stores 500 readings. LCD display with waveform,<br />

spectrum and data readout. Auto measurement function. Includes printer<br />

interface.<br />

Rion CP-10 RS-232 Printer VA10 NL05 NL14<br />

RIO,Cp-10 AU/MY<br />

printer for RIO,VA-10. Operates from optional NiCd battery pack.<br />

Rion VA-11 Vibration Analyser<br />

RIO,VA-11 AU/MY<br />

Includes 2 pickup types hand held (pV55) and magnetic type (pV57).<br />

Instrument will measure acceleration, velocity and displacement. Displays<br />

rms, peak and crest factor. Uses FFT to display power and vibration<br />

spectrum. Incorporates pCMCIA card flash memory for data storage. RS-232<br />

interface is available. Specifications pV57 1Hz~5kHz, pV55 3Hz~20kHz<br />

(velocity 3kHz, displacement 500Hz). Acceleration 0.02~316mm/s2 rms.<br />

Velocity 0.1~1,000 mm/s rms. Displacement 0.003~28.3 (EQ pp). High<br />

pass filter 3Hz, 10Hz & 1kHz. Low pass 1kHz, 5kHz & 20 kHz. Stores 500<br />

measurements.<br />

NON-DES<strong>TR</strong>UCTIVE TESTING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 89


NON-DES<strong>TR</strong>UCTIVE TESTING<br />

90<br />

vibratiOn & alignment analySiS<br />

Texcel ATM Explosion and Ground Vibration Logger<br />

TEx,ATM AU<br />

Triaxial geophone and overpressure (airblast) microphone with logger used<br />

to determine explosion and ground vibration characteristics. Geophone<br />

range to ±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s, 0.109mm/s<br />

up to 55.9mm/s. Microphone range 80-dbL~140dbL, resolution 0.049pa<br />

up to 122dbL (25pa), 0.40pa up to 140dbL (201pa). Sample rate 20, 50,<br />

100, 200, 500Hz & 1kHz. bandwidth: geophone 4.5Hz~500Hz, microphone<br />

2Hz~500Hz. Includes software and download cable. Internal memory 2Mb.<br />

power internal 12V dc 7Ah batteries. Continuous operation 240h. Supplied<br />

with 90~260V 50/60Hz charger, recharge time 8h approx. Instrument with<br />

16 character LCD display, built into weatherproof pelican enclosure, rated<br />

Ip65. Operating temperature range 0~70 O C, display 0~50 O C. Also supplied<br />

with alarm light, reset button and 2 x 15m cable, ideal for vibration sensitive<br />

construction projects. External dc power supply cable also supplied.<br />

glOSS meaSurement<br />

ARL EL-235 Tri-axial Ground Vibration Logger<br />

ARL,EL-235 AU<br />

Portable logger with human exposure capability. Monitors ground and<br />

building vibration for long periods. Calculates and stores tri-axial vibration<br />

stats, vector sum stats, peak particle velocity (ppV), rms particle velocity<br />

and human exposure (HEF) stats. Includes PC based analysis software.<br />

Sensor frequency response 1Hz~500Hz. Logs interval, date, time, Leq,<br />

Lmax, temperature, battery, L0.1, L1.0, L10 & L90. Event mode logs date,<br />

time, max and duration (Real time mode = 1000 samples/s). Stores up to<br />

4,096 intervals or events. power 70mA @ 12V.<br />

Blastronics UMX-SM-6 Explosion Logger<br />

bLA,UMx-SM-6 AU<br />

Triaxial geophones, microphone with logger used to determine explosion<br />

characteristics. Geophones auto-ranging to 110mm/s, resolution ±0.1.<br />

Microphone auto-ranging to 140dbL, resolution ±0.25db. Sample rate<br />

250, 500Hz & 1kHz. bandwidth geophones 4.5~500Hz. Microphone<br />

2~500Hz. Includes software and download cable. Internal memory 4Mb.<br />

power internal 6Vdc 2,600mAh Gel-cells, operating consumption 40mA,<br />

sleep mode 10mA. Continuous operation 65h, with 1w programmable timer<br />

schedule. Instrument has a display.<br />

Labworks LW-140-141 Vibration Table<br />

LAb,LW-140-141 AU<br />

Capable of random and sine movement. Sine force 489N, random force<br />

334N, shock force 1kN, max displacement 25mm, max velocity 17.8m/s,<br />

accel bare table 110g pk, accel 45kg 55g pk, accel 2.2kg 18g pk. Max accel<br />

resonant 150g pk, max accel peak shock 200g pk. Unit requires a signal<br />

source and an accelerometer to measure the acceleration. Signal source<br />

could be a function generator or random noise generator.<br />

Elcometer 402 Glossmeter<br />

ELC,402 AU<br />

Measures the gloss or specular reflection from a variety of surfaces. Range 0~199.9 gloss units per ISO 2813-1978. Measuring angles 60O & 20O. Aperture<br />

16 x 33mm ellipse. Digital display. Statistical functions – min, max, average, standard deviation. Stores up to 4,000 readings. RS232C interface for a printer.<br />

Operates from ac mains or internal rechargeable batteries.<br />

autOmOtive<br />

Translock Brake Tester and Light Transmittance Meters<br />

TLI,bTM2-LTM2 AU<br />

Kit contains a brake tester and a light tester check vehicle conformance for the NSW Road Worthy Certificate. brake tester measures the deceleration rate of<br />

the vehicle and the light tester measures the transmission levels of light through the windscreen.<br />

nOn-deStructive teSting<br />

> NEW<br />

Panametric NDT Epoch-LT Ultrasonic Flaw Detector<br />

pAN,EpOCH-LT AU<br />

Handheld flaw detector with fast and bright LCD mono display, update rate<br />

60Hz, automated transducer calibration. Display freeze holds waveform and<br />

soundpath data, soundpath data viewable in inch, mm or microseconds. peak<br />

memory feature, RF display mode, alarms, theshold positive/negative, or<br />

minimum depth. Numeric data logger. EMAT probe compatibility (E110-Sb).<br />

Standard DAC and TVG. Software options fitted- Echo-Echo and Square<br />

wave pulser. No probes supplied or connection cables. Refer pAN,<strong>TR</strong>AN-<br />

KIT.<br />

> NEW<br />

Panametric NDT Kit of 3 Transducers, Wedges & Cal Block<br />

pAN,<strong>TR</strong>AN-KIT AU<br />

Kit of 3 Ultasonic transducers, comprising 1x V540SM angle beam<br />

transducer 13mm, 2.25MHz, 1x V541SM angle beam transducer 13mm,<br />

5MHz, 1x Single crystal transducer, 0DEG, 13mm, 5MHz, 3x wedge, 1x<br />

45DEG, 1x 60DEG, 1x 70 DEG. 1x 1M lemo cable, 1x 5 step calibration<br />

block, 12.5, 10.0, 7.5, 5.0, 2.5mm (1018 steel).<br />

Phynix Ferrous/Non Ferrous Coating Thickness Tester<br />

pHY,SURFIx FN AU<br />

Thickness tester with memory and statistics. Supplied with external probe,<br />

calibration standards and carry pouch. Measurement range 0~1,500µm or<br />

0~60mils (selectable), tolerance ±1µm +3% of reading, resolution 0.1µm.<br />

Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min<br />

substrate thickness type F 0.5mm, type N 50µm. Calibration factory, zero,<br />

foil. Data memory 80 readings max. Interface infra-red down load data to<br />

PC utilising hyper terminal.


Defelsko FNS2 Ferrous & Non Ferrous Coating Thickness<br />

Tester<br />

DEF,FNS2 AU<br />

Storage of up to 250 readings. Supplied with external probe, calibration<br />

standards and carry pouch. Measurement range 0~1.5m or 0~60mils<br />

(selectable), tolerance 0~50mm ±1mm, +1% of reading, greater than 50mm<br />

±2µm, +1%, resolution 0.1mm. backglow display, HiLo limits audible and<br />

visible alerts when measurements exceed specified limits. Continually<br />

displays updates average, standard deviation, min/max thickness and<br />

number of readings while measuring. Hi resolution mode for greater<br />

precision. Built in infra red port for down loading data.<br />

Elektrophysik Mini-100FN Coating Thickness Meter<br />

ELE,MINI-100FN AU<br />

Measuring range 0~1500µm, tolerance ±2µm or 3% of reading. Operates<br />

on both ferrous and non-ferrous substrates.<br />

Defelsko POS100-C3 Ultrasonic Thickness Gauge<br />

DEF,pOS100-C3 AU<br />

Measure coatings on concrete, paint and lacquer on wood, paint on plastic,<br />

paint on glass, glazing on ceramic, floor coatings, etc. Range 50µ~4.5mm<br />

±2µ, ±3% of reading. Calculates max, min, mean, tolerance and SD. Stores<br />

1,500 readings in 100 groups for statistical calcs. PC interface & software.<br />

Battery operated.<br />

Defelsko Positest Pull Off Adhesion Tester for Concrete &<br />

Metal<br />

DEF,pOSITEST AU<br />

Measures the force required to pull a specified test diameter of coating away<br />

from its substrate using hydraulic pressure. Pressure is displayed in both<br />

MPa and PSI on a precision dial indicator and can be related to the strength<br />

of adhesion to the substrate. Suitable for coatings on both metal and<br />

concrete surfaces. Conforms with standards ASTM D4541 and ISO 4624.<br />

> NEW<br />

PCWI High Voltage Pulse Crest Meter<br />

pCW,HV-pULSE CREST AU<br />

Measure and indicate peak voltage.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

nOn-deStructive teSting<br />

> NEW<br />

PCWI 40kV Pulse Porosity (Holiday) Detector<br />

pCW,p40-pULSE AU<br />

Pulse porosity (Holiday) detector. Detects pinholes in coatings and wrapping<br />

above 150µm on metal substrates such as pipes and tanks. Can be used<br />

on dry or wet surfaces. 0~40kV output, 4 digit LED display of voltage, alarm<br />

sensitivity setting between dry and wet. Supplied with rechargeable battery,<br />

10h charger, red probe handle and 2m length of rubber coated cable, 60mm<br />

connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat<br />

brass wire brush, 450mm probe extension and 80mm probe extension.<br />

PCWI Hi-Lighter Holiday Detector<br />

pCW,HI-L AU/NZ<br />

Detects pinholes in coatings and wrappings on metal substrates such as<br />

pipes and tanks. 0~20kV, 3½ digit LCD display of voltage, variable alarm<br />

level. Portable with rechargeable batteries, includes probe and handle,<br />

extension probes and a variety of brass wire brushes for both flat and curved<br />

surfaces such as pipes.<br />

PCWI 30kV DC Porisity (Holiday) Detector<br />

pCW,DC30 AU<br />

DC Porosity (Holiday) detector. Detects pinholes in coatings above 150um<br />

on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display<br />

with battery indicator, display of voltage level. Alarm indicated on front panel,<br />

supplied with rechargeable battery, 10h charger, probe handle with neon<br />

and 2m length cable, 60mm connector for flat brushes, 7m earth cable with<br />

clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension.<br />

Dry conditions.<br />

PCWI 40kV Pulse Porosity (Holiday) Detector<br />

pCW,DC30-pULSE AU<br />

Pulse Porosity (Holiday) detector. Detects pinholes in coatingsand wrapping<br />

above 150um on metal substrates such as pipes and tanks. Can be used<br />

on dry or wet surfaces. 0-40kV output, 4 digit LED display of voltage, alarm<br />

sensitivity setting between dry and wet. Supplied with rechargeable battery,<br />

10 hr charger, red probe handle and 2m length of rubber coated cable, 60mm<br />

connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat<br />

brass wire brush, 450mm probe extension and 80mm probe extension.<br />

Mitutoyo S-211 Surface Roughness Gauge<br />

MIT,S-211 AU<br />

Surface roughness tester comprising an LCD display and a detachable<br />

detector/drive unit. parameters measured in Ra, Rz, and Rmax units. Tip<br />

radius 5mm. Data output. NiCd batteries.<br />

Mitutoyo SJ-201P Surface Roughness Tester<br />

MIT,SJ201-NATA AU<br />

Comprises LCD display and a detachable detector/drive unit. parameters<br />

measured in Ra, Rq, Ry, Rz, Rt, Rp, R3z, Rk, Rpk, Rvk, S, Sm, pc, mr, Mr1,<br />

Mr2, A1, A2, Vo units. Ranges: 350, 100, 50µm & 10µm, resolution from<br />

0.01~0.4µm. Tip radius 5mm. Data output. NiCd batteries.<br />

NON-DES<strong>TR</strong>UCTIVE TESTING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 91


NON-DES<strong>TR</strong>UCTIVE TESTING<br />

92<br />

nOn-deStructive teSting<br />

Mitutoyo 293-330 Digital Micrometer<br />

MIT,293-330 AU<br />

Water resistant and coolant proof (IP65) digimatic micrometer, measuring<br />

range 0~1”, 0~25mm. Resolution .00005”, 0.001mm , quantizing error<br />

±1 count, LCD display. Temperature operating range 5~40OC, storage -<br />

10~60OC. button settings: origin, zero/AbS, inch/mm, hold.<br />

Panametrics 26 mg Pocket Thickness Gauge<br />

pAN,26MG AU/NZ<br />

Range 1~500mm, fast min mode. Resolution 0.01mm. probe operates -<br />

20~150OC. Panametrics NDT 37DL-Plus Ultrasonic Thickness Gauge<br />

pAN,37DL-pLUS AU<br />

Thickness gauge with large display (A-scan), which will display the returned<br />

waveform. It has echo-echo through-paint capability. Supplied with WIN37DL<br />

pLUS software and cable. The supplied probe is 11 mm diameter with a<br />

1~500 mm operating range and a -20~500OC temperature operating range.<br />

The instrument has a MIL-STD-810E hazardous area operation.<br />

cOncrete teSting equipment<br />

ELE Type EL35-2020 Concrete Cover Meter<br />

ELE,EL35-2020 AU/NZ<br />

Non-destructive measurement of concrete thickness above steel<br />

reinforcement rods. Measures rod diameter. Depth range 360mm for rod<br />

diameters 6~40mm & 200mm depth for rod up to 6mmØ. Small search<br />

head 80H x 50mmØ. provides a high resolution capability when mapping<br />

out reinforcement structures. Range 100mm with 6mm bar to 120mm with<br />

40mm bar. battery operated.<br />

Profometer-4 Rebar Locator<br />

pRO,pROFO-4 MY<br />

Rebar locator.<br />

Steinkamp BP7 Ultrasonic Concrete Tester<br />

STE,bp7 AU<br />

Measures the time a signal takes to propagate through a material. Used for<br />

concrete refractory bricks, tile (fired and unfired), outcropping rocks, tunnel<br />

walls, frozen ground, electrolytic carbon, plastics, adhesion, cast iron and<br />

wood etc. Technique relies on the fact that the pulse velocity relates to the<br />

materials tensile strength. Instrument can be used to determine % steel in<br />

concrete, variations in the moisture content, measurements of crack depth,<br />

voids, etc.<br />

Panametrics 36DL Plus Thickness Gauge<br />

pAN,36DLpLUS AU<br />

Large display (A-scan), which displays the returned waveform. Echoecho<br />

through-paint capability. Supplied with WIN95 software and cable.<br />

Supplied probe is 11mmØ with 1~500mm operating range and -20~500OC temperature operating range. Instrument has a MIL-STD-810E hazardous<br />

area operation.<br />

Panametrics 25DLHP Thickness Gauge<br />

pAN,25DLHp AU<br />

Designed for fiberglass, rubber composites and castings. Measures<br />

standard steel, copper, etc. Does echo-echo measurements. Measures<br />

the thickness of material under paint, etc. built in 5,000 reading datalogger<br />

and an RS232 port.<br />

Krautkramer DMS Thickness Gauge<br />

KRA,DMS AU<br />

Complete with echo verification and logger. Includes high temperature probe<br />

and cable. Incorporates a wave form display for accurate assessment of<br />

material under test, measurement of thickness whilst ignoring external paint.<br />

probe will operate to 200OC without cooling, up to 540OC with cooling.<br />

Measurement ranges 0.75mm~250mm (for different ranges other probes<br />

are available). Resolution 0.01mm. Stores up to 80,000 readings or 1,200<br />

readings with full waveform information.<br />

Sonatest Thickness Gauge<br />

SON,T-GAGE-IV+ AU/MY<br />

Range 0.63~500mm, resolution 0.01mm, high speed scanning mode,<br />

selectable backlight, alarm mode, differential mode, RS232C output,<br />

data send using hyper terminal. Supplied with high temperature probe,<br />

temperature range 0~340ºC.<br />

Protimeter SM Moisture Meter<br />

pRO,SM AU<br />

Moisture meter for survey work. Very good for determining wet points. Can<br />

be used on both concrete and timber. Subsequent accurate measurements<br />

can then be made.<br />

Proceq LR Concrete Test Hammer<br />

pRO,LR AU<br />

Concrete hardness tester (Schmidt hammer). Supplied with in-built<br />

mechanical chart recorder. Impact energy 0.735Nm, 0.075kgm. For concrete<br />

thickness less than 100mm.<br />

Protimeter CMIII Concrete Moisture Meter<br />

pRO,CMIII AU<br />

Measures concrete moisture content using 2 methods. Firstly using<br />

impedance as a direct instant method. Secondly an accurate method<br />

requiring placing a box on the concrete and measuring the humidity<br />

generated by the concrete.


Protimeter Moisture Measurement System<br />

pRO,MMS-pLUS AU<br />

Moisture meter for detection of moisture in non conductive solid materials<br />

such as wood and masonry. Two measurement modes, search for qualitaive<br />

measurements and measure mode for precise and locaised moisture<br />

content. Supplied with pin type probes, deep wall probes, hygrometer probe<br />

and extention cord,for RH, ambient temperature or dew point temperature.<br />

Hygrostick probe supplied for surface temperature measurement. Logging<br />

software and RS232 computer interface supplied.<br />

Proceq 2000-ND Digi Schmidt Test Hammer<br />

pRO,2000-ND AU<br />

Concrete hardness tester (Schmidt hammer). Supplied complete with inbuilt<br />

graphical LCD for setting up and graphical display of results,up to 500 results<br />

can be stored. RS232 interface and software supplied for down loading.<br />

Impact energy 2.207Nm. Engineering units of results in N/mm2, Mpa, psi,<br />

kg/cm2. For concrete thickness greater than 100mm.<br />

Olsen FTG Concrete Thickness Gauge<br />

OLS,FTG AU<br />

Concrete thickness gauge utilising the impact Echo test method. Can<br />

measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m.<br />

This concrete thickness gauge is a battery operated handheld system for<br />

measuring the flaws and thickness of concrete slabs, pavements, walls and<br />

other plate-like structures from one side. Up to 300 readings can be stored<br />

in the field before the memory is full. RS232 interface and transfer software<br />

supplied.<br />

Krautkramer DynaPocket Rebound Hardness Tester<br />

KRA,DYNApOCKET AU<br />

based on the Leeb’s method HL, utilising a 3mm tungsten carbide ball.<br />

Other hardness scales can be selected, HS Shore, Hb brinell, HRb Rockwell<br />

b, HRC Rockwell C, HV Vickers and N/mm 2 tensile strength. Choice of 9<br />

material groups can be selected, they are St Low-alloy/unalloyed steel and<br />

cast steel, ASt Tool steel, SSt Corrosion resistant steel, GCI Gray cast iron,<br />

NCI Nodular graphite cast iron, AL Aluminium cast alloys, brS brass, brZ<br />

bronze, Cu Wrought copper alloys.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

cOncrete teSting equipment<br />

Hilti PS20 Rebar, Copper Pipe & Electrical Cable Locator<br />

HIL,pS20 AU<br />

Localise and position of reinforcement, (rebars) copper, aluminium pipes<br />

and unshielded live electric cables. Depth range for detection of rebars<br />

0~100mm, for copper & aluminium pipes 60mm, rebar diameter 8~36mm,<br />

depth detection accuracy 10~30mm ±2mm, above 30-60mm ± 2mm ±10%<br />

depth, above 60~80mm ±5mm ±10% depth, based on 12mm rebars.<br />

Detection of copper & aluminium pipes based on 10~30mmØ, only detection<br />

with depth of 0~60mm, no depth reading, same for live electric cables,<br />

cannot detect live cables in metal conduit or shielded cables.<br />

Hilti Ferroscan Concrete Reo Scanner<br />

HIL,FERROSCAN AU<br />

Reinforced concrete imaging system. Displays depth of concrete coverage,<br />

location of reinforcement rods and anchor setting points. Fast, simple<br />

operation. Depth mode allows reinforcement rods at different depths to<br />

be viewed. Printer interface and PC interface and software allow images<br />

to be printed and/or stored for further use. Depth coverage up to 180mm.<br />

Reinforcement rod diameter measurement range 6~36mm. Area covered<br />

in a single measurement run 600 x 600mm; 42 image memory allows total<br />

15m 2 coverage without downloading.<br />

hardneSS teSterS<br />

Proceq Equotip Hardness Tester<br />

pRO,EQUOTIp AU<br />

Test probe on a flexible lead. Probe type D is standard catering for most<br />

materials. Measurement ranges steels 80~650Hb, 80~940HV, 20~68HRC,<br />

aluminium castings 20~160Hb, cast iron 90~380Hb, brass 40~170Hb &<br />

copper wrought alloys 43~315Hb. Test hardness must not exceed 940HV.<br />

Battery operated.<br />

Bareiss HPE FM02177 Shore A Hardness Tester<br />

bAR,HpE-FM02177 AU<br />

Durometer tester for general rubber, elastomer, soft plastic, tires, rubber<br />

rolls & rubber hoses. Surface min 35mmØ, material thickness of 6mm are<br />

necessary for a hardness test according to the standards. Hardness tests<br />

can be conducted in a vertical, horizontal positions and on places which are<br />

difficult to reach. Test time setable from 0~30s. Reading exactness of ±0.5<br />

Shore and according to set down standards deviation of ±1 Shore.<br />

NON-DES<strong>TR</strong>UCTIVE TESTING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 93


GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

94<br />

induStrial calibratOrS<br />

Model Type<br />

Analog<br />

Out<br />

Pressure<br />

(Bar)<br />

Vacuum<br />

(Bar)<br />

Battery RS232 Accuracy %<br />

AMb,CAL-20MpA Pressure pneumatic 200 0.5 fs<br />

AME,HL2700N Dead weight tester hydraulic 225 0.05 reading<br />

AME,ppCE-NATA* Pressure hydraulic 700<br />

Current<br />

mA<br />

0.04 reading 50<br />

bEA,bIC200 Industrial incl. Pressure 1 100 50<br />

DRU,DpI603-10-NATA*<br />

10<br />

Current<br />

Source mA<br />

DRU,DpI603-20 20<br />

0.85 0.075 fs<br />

55<br />

DRU,DpI603-2NATA* 2<br />

Pressure pneumatic<br />

DRU,DpI603-20NATA* 20 Yes<br />

55<br />

DRU,DpI610-20NATA* Yes Yes 0.025 fs 24<br />

Yes<br />

DRU,DpI610-160 160 0.025 fs 24<br />

DRU,UpS-3<br />

0.01 24<br />

Current loop<br />

DRU,UpS-IS 0.25 55<br />

FLU,725<br />

FLU,725-NATA*<br />

FLU,743b<br />

FLU,744 Industrial (hart)<br />

FLU,700S/W-DpC-<br />

<strong>TR</strong>ACK<br />

Industrial 110 22<br />

S/ware for Fluke 743b & 744<br />

GRA,W6-NATA* Water bath 0.1<br />

HAL,KAL84 Very low pressure 10 Yes Linearity ±0.5%<br />

DRU,DbC150TC<br />

HAR,9100-A 0.5°C<br />

HAR,9105-NATA*<br />

Dry well temperature<br />

HAR,9107-NATA* Yes 0.1°C<br />

HAR,9141-NATA* 0.5<br />

JOF,LpC-NATA* Pressure Yes 10 0.8 Yes 0.1 fs 200m<br />

SER,NOVA-1 Dry well temperature 0.1°C<br />

SI,pC6-2-NATA*<br />

SI,pC6-20-NATA* Pressure pneumatic<br />

20<br />

YES<br />

SI,pC6-40-NATA* 40<br />

Sp,pC6-1000-NATA*<br />

2 0.85<br />

1.0<br />

Yes<br />

0.3°C<br />

0.1<br />

Yes Yes 0.025 fs 50 50<br />

HAR,9150 Thermocouple furnance No Yes ±0.5°C<br />

HAR,9170-R-NATA* Metrology well calibrator Yes ±0.01°C<br />

HAR,3125-NATA*<br />

Temperature surface probe<br />

calibrator<br />

Yes<br />

±0.5°C~200°C,<br />

±1%~400°C<br />

JOF,1200SE Temperature calibrator 150~200°C<br />

HAR,7102-NATA*<br />

HAR,7103-NATA*<br />

FLU,718<br />

Temperature micro bath Yes ±0.25°C<br />

SI,pC6-pRO 350 350<br />

Pressure calibrator<br />

DRU,DpI610-2-NATA* 2 -1 Yes 0.025°C ±55 0~24<br />

DRU,DpI610-400-NATA* 400 Yes 0.025°C ±55 0~24<br />

* Nata Calibrated<br />

SI,HTP1<br />

1,000<br />

Pressure pump<br />

SI,TpI-40 40 -1<br />

Yes


Model Type<br />

Freq<br />

kHz<br />

Freq<br />

Source<br />

kHz<br />

Loop<br />

Power<br />

V<br />

Resist<br />

Measuremt<br />

RTD/<br />

TC<br />

Temp<br />

Source °C<br />

AME,ppCE-NATA* Pressure hydraulic 30<br />

bEA,bIC200 Industrial incl. Pressure 48 200Ω 100<br />

DRU,DpI603-10-NATA*<br />

DRU,DpI603-20<br />

DRU,DpI603-2NATA*<br />

induStrial calibratOrS<br />

Voltage<br />

Max V<br />

50<br />

Voltage<br />

Source V<br />

DRU,DpI603-20NATA*<br />

DRU,DpI610-20NATA*<br />

DUR,DpI610-20IS<br />

Pressure pneumatic 24<br />

DRU,DpI610-160 24 10<br />

DRU,UpS-3<br />

DRU,UpS-IS<br />

Current loop<br />

FLU,701-NATA*<br />

500<br />

FLU,725<br />

FLU,725-NATA*<br />

Industrial<br />

50 5<br />

24 11kΩ Yes 300 11<br />

FLU,743b<br />

FLU,744 Industrial (hart)<br />

500<br />

FLU,700S/W-DpC-<br />

<strong>TR</strong>ACK<br />

S/ware for Fluke 743b & 744<br />

GRA,W6-NATA* Water bath 0~150<br />

HAL,KLA84 Very low pressure<br />

DRU,DbC150TC<br />

-45 (below amb) ~ 150<br />

HAR,9100A 40~300<br />

HAR,9105-NATA*<br />

HAR,9107-NATA*<br />

Dry well temperature<br />

40~650<br />

-45~140<br />

HAR,9141-NATA* 40~650<br />

SER,NOVA-1<br />

SI,pC6-2-NATA<br />

200~1,000<br />

SI,pC6-20-NATA*<br />

SI,pC6-40-NATA*<br />

Pressure pneumatic<br />

24 24 10<br />

Sp,pC6-1000-NATA* Pressure Hydraulic<br />

HAR,9150 Thermal couple furnance 150~1,200<br />

HAR,9170-R-NATA* Metrology well calibrator -45~140<br />

HAR,3125-NATA*<br />

Temperature surface probe<br />

calibrator<br />

35~400<br />

JOF,1200SE Temperature calibrator 150~1,200<br />

HAR,7102-NATA*<br />

HAR,7103-NATA*<br />

FLU,718<br />

Temperature micro bath<br />

-5~125<br />

-30~125<br />

SI,pC6-pRO 350<br />

DRU,DpI610-2-NATA*<br />

Pressure calibrator<br />

+50 10,24<br />

DRU,DpI610-400-NATA* +50 10,24<br />

SI,HTP1<br />

SI,TpI-40<br />

* Nata Calibrated<br />

Pressure pump<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 95


GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

96<br />

induStrial calibratOrS<br />

Fluke 5500A Multi Product Calibrator with NATA Calibrated<br />

FLU,5500A-NATA AU<br />

Calibrator sources direct voltage & current, alternating voltage and current,<br />

with multiple waveforms and harmonics, 2 simultaneous voltage outputs<br />

or voltage & current. Simulates power with phase control, resistance,<br />

capacitance, thermocouples and RTDs. Selectable ranges include the<br />

following outputs Vdc from 0~1.02kV, Vac from 1mV~1.02kV with output from<br />

10Hz~500kHz. AC current from 0.01µA~11A with output from 10Hz~10kHz.<br />

DC current from 0~11A. Resistance values from short circuit to 330MΩ.<br />

Capacitance values from 330pF~1,100µF. Temperature t/c b, C, E, J, K, L,<br />

N, R, S, T, U, RTD pt385 100Ω, pt3926 100Ω, pt3916 100Ω, pt385 200Ω,<br />

pt385 500Ω, pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.<br />

Fluke 725 Process Calibrator<br />

FLU,725 NZ<br />

DC voltage measurement 0.025%, 300V max, source 0.02%, 11V max.<br />

DC current measurement 0.025%, 110mA max, source 0.01%, 22 mA<br />

max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ<br />

max. Frequency measurement 5 counts 1Hz~50kHz, source 1 count<br />

20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC. pt100<br />

RTD measurement 0.5ºC, source 0.2ºC. Measures and simulates 4~20mA,<br />

t/c E, N, J, K, T, b, R, S, & C, 2, 3 & 4 wire RTDs and frequency. Operates<br />

from drycell batteries.<br />

Fluke 725 Process Calibrator NATA Calibrated<br />

FLU,725-NATA AU<br />

Specification as above but with NATA calibration.<br />

Fluke 743 Calibrator<br />

FLU,743b AU/MY<br />

Includes RS232 interface. DC voltage measurement 0.025%, 300V max,<br />

source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,<br />

source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max,<br />

source 0.01%, 11kΩ max. Frequency measurement 0.5%, +5, 40~500Hz,<br />

source 1 count 20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source<br />

0.3OC pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and<br />

simulates 4~20mA, t/c E, N, J, K, T, b, R, S, & C, 2, 3 & 4 wire RTDs,<br />

frequency, test limit switches. Can use scaling factors for measurement &<br />

source. built in calculator. Autostep function. Allows user entered values.<br />

Operates as a 8k point data logger. Note pC software only supports 15<br />

tags.<br />

Fluke 744 DOC Calibrator with Hart<br />

FLU,744 AU/NZ/MY<br />

Documenting process calibrator which includes HART communication<br />

protocols for communicating with and setting up smart transmitters. RS232<br />

interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V<br />

max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA<br />

max. Resistance measurement 0.05%, 11kΩ max, source 0.01% 11kΩ max.<br />

Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’<br />

thermocouple measurement 0.3ºC, source 0.3ºC pt100. RTDs measurement<br />

0.3ºC, source 0.1ºC. Measures and simulates 4~20 mA, t/c E, N, J, K, T, b,<br />

R, S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling<br />

factors for measurement & source. built in calculator. Autostep function.<br />

Allows user entered values. Operates as an 8k point data logger. Note pC<br />

software only supports 15 tags.


Fluke 700 Pxx Series Pressure Modules<br />

FLU,700pxx NZ<br />

Assortment of pxx series pressure modules for the Fluke 741/744 process<br />

calibrators.<br />

Druck DBC150TC Dry Well Calibrator Calibrator<br />

DRU,DbC150TC AU<br />

Temperature range -45(below ambient)~150ºC. Accuracy 0.3ºC, resolution<br />

0.01ºC, stability 0.03ºC. Well standard insert supplied 145mm deep, 5, 6.6<br />

& 9.8mmØ. Heating time 14min 20~120ºC, cooling time 22min 25~-20ºC.<br />

Calibrator also measures sensor outputs, it can measure 5 types of RTD<br />

& 11 types of thermocouple. Supports 2, 3, 4 wire RTD and provides cold<br />

junction compensation for thermocouples.<br />

Hart 9105 Dry Block Temperature Calibrator -25~140ºC NATA<br />

HAR,9105-NATA AU<br />

HAR,9105 MY<br />

Range -25~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232<br />

interface for ramp and soak programming. Well dimensions 150mm deep,<br />

19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.<br />

Hart 9107 Dry Block Temperature Calibrator -45~140ºC NATA<br />

HAR,9107-NATA AU<br />

Range -45~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232<br />

interface for ramp and soak programming. Well dimensions 150mm deep,<br />

19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.<br />

> NEW Hart 9170-R Metrology Well Calibrator with Built-in<br />

Reference & NATA Certification<br />

HAR,9170-R-NATA AU<br />

Temperature range -45~140ºC with bult in reference thermometry. Reference<br />

input accepts (not supplied) 100, 25 and 10ohm pRT’s. Display accuracy +/-<br />

0.1ºC, stability +/-0.005ºC full range, resolution 0.001ºC. Well depth 6.3”,<br />

insert type A 1/4, 3/16, 1/4, 1/8, 1/4, 3/8”. Large LCD, numeric keypad and<br />

on screen menus. Heating time 32min 23~140ºC, 45 minutes -45~140ºC,<br />

cooling time 44min 23~-45ºC, 19min 140~23ºC. Supplied with RS232C<br />

interface and CD-ROM software.<br />

Hart 9100-A Dry Block Temperature Calibrator 30~300OC<br />

HAR,9100-A NZ<br />

Stability is 0.2ºC @ 50OC & 0.3ºC @ 300ºC. Accuracy for 35~200ºC ±0.5<br />

for 200~300ºC ±1, for well holes greater than ¼” ±2ºC.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

induStrial calibratOrS<br />

> NEW Hart 3125 Surface Probe Calibrator 35~400ºC NATA<br />

Certification<br />

HAR,3125-NATA AU<br />

Temperature range 35~400ºC. Display accuracy ±0.5~200ºC, ±1~400ºC.<br />

Stability ±0.2~300ºC, ±0.3~400ºC. Resolution 0.01º. Heating time<br />

25~400ºC 22min. Cooling time 400~100ºC 65min. Temperature surface<br />

plate 3.8ӯ accessible.<br />

Hart 9141 Dry Block Temperature Calibrator 50~650ºC<br />

HAR,9141-NATA AU<br />

Range 50~650ºC, basic accuracy 0.5% (holes > ¼” 2ºC). Insert hole sizes<br />

1/16”, 1/8”, 3/16”, ¼”, 3/8” & ½”. Includes pC software and interface cable.<br />

Heating time 1min to 650ºC. Cooling 25min from 650ºC~100ºC. Well depth<br />

4.875”. Stabilization time 7min.<br />

Hart 9150 Furnace 150-1200ºC<br />

HAR,9150 AU<br />

Temperature range 150~1200ºC. Stability ±0.5ºC, display accuracy of ±5ºC<br />

across entire range. Display resolution 0.1º~999.9ºC, 1º above 1,000ºC.<br />

Well diameter 1.25”, well depth 5.5”, insert type A. 1/16”, ¼”, ⅜”, 3/16”, ⅛”,<br />

½”. Heating time 35min to 1,200ºC, cooling time 140min.<br />

Jofra 1200SE Precision Temperature Calibrator<br />

JOF,1200SE MY<br />

Lightweight, portable for lab and general use. Simple single step zero setting.<br />

Temperature range 300~1200ºC. Excellent performance characteristics.<br />

Accuracy +2ºC. Stability +0.5ºC. Display in ºC or ºF to 0.1 resolution. Fast<br />

cooling and heating. User-selectable slope rates for controlled thermo switch<br />

testing. Self diagnostics includes semi-auto Switch Test & Hysteresis Test.<br />

Grant W6 Temperature Bath NATA Certified<br />

GRA,W6-NATA AU<br />

Water/oil bath calibrator for calibrating temperature probes. Ranges water<br />

ambient 100ºC; silicon oil ambient; 150ºC. Requires 3L oil (not supplied).<br />

Digital temperature controller and display. Stability 0.004ºC. Uniformity<br />

0.01ºC. Display resolution 0.1ºC. Tank size 300w x 150d x 150hmm.<br />

GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 97


GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

98<br />

induStrial calibratOrS<br />

> NEW<br />

Hart 7102 Temperature Micro Bath -5~125ºC<br />

HAR,7102-NATA AU<br />

Range -5~125ºC. Tank diameter 1.9”, 5.5” deep, volume 0.75L, includes<br />

tank lid. Accuracy ±0.25ºC, stability ±0.015ºC at -5OC, ±0.03ºC @ 121ºC,<br />

resolution ±0.01ºC. Heating time 25~100OC 30min, cooling time 25~0ºC<br />

30min. RS232C interface and CD-ROM sofware supplied.<br />

> NEW<br />

Hart 7103-NATA Micro Bath -30~125ºC NATA Certification<br />

HAR,7103-NATA NZ<br />

Temperature range -30~125ºC. Tank 2.5”Ø, 5.5” deep, volume 1L, includes<br />

tank lid. Accuracy ±0.25ºC, stability ±0.03ºC @ 25ºC, ±0.05ºC @ 125ºC,<br />

resolution ±0.01ºC. Heating time 25~100ºC 35min, cooling time 25~-20ºC<br />

45min. RS232C interface and CD-ROM software supplied.<br />

Druck UPS-IS Current Loop Calibrator<br />

DRU,UpS-IS AU<br />

Intrinsically safe 4~20mA source and measurement. provides 24V loop<br />

power. Accuracy 0.25%. Input and output resolution 10µA.<br />

Beamex BIC200 Instrument Calibrator<br />

bEA,bIC200 AU/MY<br />

For both electronic and pneumatic instruments. Output ranges settable to<br />

119.9% of range 0~10V, 1~5V, 4~20mA, 0~20mA, 10~50mA & 0~50mA.<br />

Output source for current ranges 24 & 48V. Input ranges to 4½ digit display<br />

100mV, 1, 10 & 100V, 100mA, 4~20mA, 200Ω. pressure measurement<br />

ranges 0~1bar & 0.2~1bar. Operates from internal NiCd batteries or external<br />

ac.<br />

Halstrup KAL84 0-1kPa Portable Pressure Calibrator<br />

HAL,KAL84 AU<br />

portable battery operated 0-1.000kpa (0-10mbar) low pressure calibrator.<br />

Linearity ±0.5% ±1 digit, hysteresis 0.1%, medium - air and all non<br />

aggressive gases, pressure connections 6.5mm hose NW5, interior tubing<br />

5mmØ. Analogue output 0-1V, display 41/2 digit, power supply via mains<br />

adaptor 100-240Vac & NiCd re chargable battery pack.<br />

> NEW<br />

Jofra C650 Calibrator<br />

JOF,C650 MY<br />

A fast, timesaving, and reliable true temperature calibrator designed for onsite<br />

use. produces temperatures between 33~650°C. Display resolution<br />

±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth 120mm x 28Ømm.<br />

Comes with a multi-hole insert of ⅜”,¼”, 3/16” & ⅛”Ø holes. Light weight<br />

and portable.<br />

Jofra LPC Pressure Calibrator NATA Calibrated<br />

JOF,LpC-NATA AU<br />

Range to 10bar (145psi). Display 4½ digit, can display in bar, psi, mercury &<br />

H Og. Analogue output 2Vdc. Includes adaptors ¼”bSp to various bSp &<br />

2<br />

NPT. Measures pressure and vacuum. Battery operated.<br />

Druck DPI603 2Bar Pressure Calibrator NATA Calibrated<br />

DRU,DpI603-2NATA AU<br />

Accuracy 0.075% fs includes pump for vacuum and pressure. pumps to<br />

20bar pressure & -850mbar vacuum. Measurements can be made to 2bar<br />

positive pressure & -1bar vacuum. Unit has a 24V energising voltage.<br />

Monitors loop current to 55mAdc loop voltage to 50V. Sealed to Ip65.<br />

Rechargeable battery operated. Displays in 24 different units. Interface<br />

1<br />

/8 ”bSp.<br />

SI PC6-2-NATA Pressure Calibrator & Pump -1~2Bar 0.025%<br />

Accuracy<br />

SI,pC6-2-NATA AU<br />

SI,pC6-2 MY<br />

Range -1~2bar. Measures voltage 0~100mV (1µV resolution), 0~5V (0.1mV<br />

resolution) & 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all<br />

at 0.025% accuracy. Will sources 0~10V (0.2mV resolution) & 0~50mA (1µA<br />

resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1%,<br />

current 30mA and unregulated supply 24V ±10% current 50mA. pressure<br />

switch status. Complete with a full range of pressure connection adaptors.<br />

Record logging capability 444 and RS232 interface download to spread<br />

sheet files. Battery operation 10h or mains operation via charger.<br />

SI PC6 Pressure Calibrator & Pump 20 Bar 0.025% Accuracy<br />

SI,pC6-20-NATA AU<br />

basic accuracy 0.025%. Range output pressure to 20bar, output vacuum<br />

to -1bar. NATA certified Instrument. Measures voltage 0~100mV (1µV<br />

resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current<br />

0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />

resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage<br />

output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />

±10% current 50mA. pressure switch status. battery operation 10h or mains<br />

operation via charger. Complete with a full range of pressure connection<br />

adaptors.<br />

SI PC6-40-NATA Pressure Calibrator & Pump NATA Certified<br />

SI,pC6-40-NATA AU<br />

basic accuracy 0.025%. Range is 40bar. Measures voltage 0~100mV (1µV<br />

resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current<br />

0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />

resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage<br />

output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />

±10% current 50mA. pressure switch status. Complete with a full range<br />

of pressure connection adaptors. Record logging capability 444 and RS232<br />

interface download to spread sheet files. Battery operation 10h or mains<br />

operation via charger.


induStrial calibratOrS<br />

SI PC6-PRO 350Bar Pressure Calibrator & HTP1 Hydraulic<br />

Pump<br />

SI,pC6-pRO 350 MY<br />

Range 0~350bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV<br />

resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all<br />

@ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA<br />

resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />

30mA & unregulated supply 24V ±10% current 50mA. pressure switch<br />

status. Pressure media oil, water & non corrosive gases. Battery operation<br />

10h or mains operation via charger. Complete with a full range of pressure<br />

connection adaptors.<br />

SI PC6 700Bar Pressure Calibrator & HTP1 Hydraulic Pump<br />

NATA Calibrated<br />

SI,pC6-700-NATA AU<br />

SI,pC6-700 MY<br />

Range 0~700bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV<br />

resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all<br />

@ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1uA<br />

resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />

30mA & unregulated supply 24V ±10% current 50 mA. pressure switch<br />

status. Pressure media oil, water & non corrosive gases. Battery operation<br />

10h or mains operation via charger. Complete with a full range of pressure<br />

connection adaptors.<br />

SI PC6 Pressure Calibrator & Pump 1000 Bar<br />

SI,pC6-1000-NATA<br />

Range is 1,000bar. Nata calibrated Instrument. Measures Voltage 0~100mV<br />

(1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) &<br />

current 0~50mA (1µA resoultion) @ 0.025% accuracy. Sources 0~10V<br />

(0.2mV resolution) & 0~50mA (1µA resolution) @ 0.025% accuracy.<br />

Voltage output regulated 10V ±0.1% current 30mA and unregulated supply<br />

24V ±10% current 50mA. pressure switch status. pressure media oil and<br />

water (unit can measure non corrosive gases but not pump them). Battery<br />

operation 10h or mains operation via charger. Complete with a full range of<br />

pressure connection adaptors.<br />

SI Pressure HTP1 Pressure Pump<br />

SI,HTP1 NZ<br />

Hand operated hydraulic pressure pump, capable of 700bar. Quick priming<br />

and pressure generation. High pressure/priming selector. Fine adjustment<br />

control. pressure release valve. Supplied with integral IANZ calibrated<br />

digital gauge. Uses paraffin oil as the working fluid.<br />

SI Pressure TP1-40 Pressure Pump<br />

SI,Tp1-40 NZ<br />

Fully portable hand operated dual source of pneumatic pressure and vacuum.<br />

Generates up to 40bar pressure or 96% vacuum. Adjustable stroke to<br />

provide over pressure protection. Supplied with thread adaptors. Reference<br />

gauge is required, see optional Fluke pressure modules FLU,700pxx.<br />

Druck DPI603 Pressure Calibrator 10Bar NATA Certified<br />

DRU,DpI603-10-NATA AU<br />

Displays in 24 different units. Interface ⅛”bsp. Accuracy 0.075%fs, includes<br />

pump for vacuum and pressure. pumps to 20bar pressure & -850mbar<br />

vacuum. Measurements can be made to 20bar positive pressure & -1bar<br />

vacuum. Unit has a 24V energising voltage. Monitors loop current to<br />

55mA dc @ ±0.075% reading & 0.005%fs. Monitors loop voltage to 50V @<br />

±0.15% of reading & 0.02%fs. Unit sealed to Ip65. battery life per charge<br />

is approx 40h (no 24V load).<br />

Druck DPI603 Pressure Calibrator 20Bar<br />

DRU,DpI603-20 AU/MY<br />

Accuracy 0.075%fs. pumps up to 20bar pressure & -850mbar vacuum.<br />

Measures up to 20bar pressure & -1bar vacuum. In-built 24V energising<br />

voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface<br />

⅛”bsp. battery operated.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Druck DPI603 Pressure Calibrator 20Bar NATA Certified<br />

DRU,DpI603-20NA AU<br />

Includes pump for vacuum and pressure can display in 24 different units.<br />

Interface ⅛”bsp. Accuracy 0.075%fs. pumps 20bar pressure & -850mbar<br />

vacuum. Measurements can be made to 20bar positive pressure & -1bar<br />

vacuum. Unit has a 24V energising voltage. Monitor loop current to<br />

±55mAdc @ ±0.075% reading & 0.005%fs. Monitor loop voltage to 50V @<br />

±0.15% of reading & .02%fs. Unit is sealed to Ip65. battery life per charge<br />

is approx 40h (no 24V load)<br />

Ambit Calibration Kit 20MPa<br />

AMb,CAL-20MpA AU<br />

20Mpa gauge with hydraulic hand pump, accuracy 0.5%fs.<br />

Druck DPI610HC 160Bar Pressure Calibrator<br />

DRU,DpI610-160 AU<br />

Hydraulic pressure calibrator including pump and current voltage standard.<br />

pressure range 160bar ±0.025%fs. Voltage input ±50Vdc, ±0.05% reading<br />

& ±0.004%fs. Current input ±55mA, ±0.05% reading & ±0.004%fs.<br />

Temperature 10~40OC, ±1 (ambient) switch open/closed. Voltage output<br />

10Vdc, ±0.1% or 24V ±5%. Current output 0~24mA, ±0.05% reading &<br />

±0.01%fs. Datalogger stores up to 10,000 values. mA ramp configurable.<br />

Pressure port G 1 / “(f). pump includes screw adjustment.<br />

><br />

8<br />

NEW Druck DPI610~20~NATA 20Bar Pressure Calibrator<br />

NATA Certification<br />

DRU,DpI610-20-NATA AU<br />

Pneumatic pressure calibrator including pump and current voltage standard.<br />

pressure range -1~20bar ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg,<br />

±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature<br />

-10~40°C ±1°C (ambient) switch open/closed. Voltage output 10Vdc ±0.1%<br />

or 24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger<br />

stores upto 10,000 values. mA ramp configurable. pressure port G ⅛f,<br />

includes flexible hose kit. pump includes screw adjustment.<br />

> NEW<br />

Druck DPI610~20IS Pressure Calibrator<br />

DRU,DpI610-20IS MY<br />

Ranges -1~20bar. Accuracy 0.025% fs all ranges. Integral combined<br />

pressure/vacuum pump. Dual readout: input & output. 4~20mA loop<br />

test: auto step and ramp. RS232 interface and fully documenting version.<br />

Remote pressure sensors. Intrinsically safe version.<br />

GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 99


GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

100<br />

induStrial calibratOrS<br />

Druck DPI610-2-NATA 2 Bar Pressure Calibrator<br />

DRU,DpI610-2-NATA AU<br />

Pneumatic pressure calibrator including pump and current voltage standard.<br />

pressure range -1~2bar, ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg,<br />

±0.004%fs. Current input ±55mA, ±0.05%rdg, ±0.004%fs. Temperature -<br />

10~40°C, ±1 (ambient) switch open/closed. Voltage output 10Vdc, ±0.1% or<br />

24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger stores<br />

up to 10,000 values. mA ramp configurable. pressure port G 1 / 8 ” (f), includes<br />

flexible hose kit. pump includes screw adjustment.<br />

Druck DPI610-400-NATA 400 Bar Pressure Calibrator<br />

DRU,DpI610-400-NATA AU<br />

DRU,DpI610-400 MY<br />

Hydraulic pressure calibrator including pump and current voltage standard.<br />

pressure range 0~400bar ±0.025%fs. Voltage input 50Vdc, ±0.05%rdg,<br />

±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature<br />

-10~40ºC ±1ºC (ambient) switch open/closed. Voltage output 10Vdc ±0.1%<br />

or 24V ±5%. Current output 0~24mA, ±0.05% rdg, ±0.01%fs. Data logger<br />

stores up to 10,000 values. mA ramp configurable. pressure port G 1 / 8 ” (f),<br />

includes flexible hose kit. pump includes screw adjustment.<br />

ultraSOnic bathS<br />

Soniclean 1000HT Ultrasonic Cleaning Bath<br />

SON,1000HT AU<br />

Tank size 495w x 295d x 150h mm includes heater and timer.<br />

> NEW<br />

Druck Loop Calibrator<br />

DRU,UpS-3 AU<br />

Measure and source 0~24mA, accuracy 0.01% of reading, dual mA and %<br />

readout, linear or flow. Step, span check, valve check, ramp. Measurement<br />

and continuity 60Vdc. HART compatible internal 235Ω loop resistor, menu<br />

selectable. Large graphic LCD.<br />

Ametek PPCE 700 Bar Pressure Calibrator<br />

AME,ppCE-NATA AU/MY<br />

High pressure calibrator with pump 700bar (10,000psi). Digital display with<br />

5 digit resolution. Accuracy over 70bar ±0.07. Accuracy below 70bar ±0.35.<br />

Current and voltage measurement ranges 4~20mA, 0~50mA & 0~30V.<br />

Ametek Hydralyte HL2700N Dead Weight Tester<br />

AME,HL2700N AU/MY<br />

Dual range interchangeable piston:-100~4,500kpa, 0.5kpa increments,<br />

500~22,500kpa, 1kpa increments. Accuracy 0.05% of reading. Includes<br />

special calculator for high accuracy pressure calculations and also<br />

conversion of units.<br />

Soniclean 2000HT Ultrasonic Cleaning Bath<br />

SON,2000HT AU<br />

Tank size 495w x 295d x 299h mm includes heater and timer.


NEW<br />

Angelantoni CH340 Environmental Temperature Chamber<br />

ACS,CH340C AU<br />

Temperature range -75~180ºC, humidity range from 10~98% RH in the<br />

range of 10~80ºC, dew point range 2~94ºC for continuous tests. Relative<br />

humidity accuracy ±1%~±3%. Capacity 336lt. Internal 600w x 800d x 700h<br />

mm. External dimensions 850w x 1725d x 1516h mm. Control by uPLC &<br />

graphical control panel on the door. Program temp & RH cycles and control<br />

all chamber functions and alarms. Entry port, door with inspection window,<br />

internal lighting, 1 shelf, RS232C interface. Electrical rated power 5.7kW,<br />

maximum used power 9kW. Voltage 400 +6%, -10%, 50Hz, 3ph. Noise<br />

63dbA , weight 750kg approximately including transit case.<br />

ACS CH106C Temperature & Humidity Environmental Chamber<br />

ACS,CH160C AU<br />

Temperature range -70~180ºC, humidity range from 20~95%RH in the range<br />

of 10~80ºC, dew point range 5~79ºC for continous tests. Realtive humidity<br />

accuracy ±1%~±3%. Useful capacity 178L, internal 560w x 564d x 560h<br />

mm. External dimensions 760w x 1115d x 1370h mm. Control by micro<br />

pLC and control panel placed on the door (4 lines alphanumeric display and<br />

keyboard). pLC programs Temp & RH cycles and to control all chamber<br />

functions and alarms. Entry port 80Ømm, door with 230 x 230mm window,<br />

internal lighting, 1 shelf, RS232C interface. Dissipation at -55ºC,100W.<br />

Electrical power 4.5kW (average 3.3kW). Voltage; 230V +6%, -10%, 50Hz,<br />

1ph. Noise 60dbA measured at 1m from the front in a non reverberating<br />

room. Weight; 390kg (excluding transit case).<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

envirOnmental teSt chamberS/OvenS<br />

Model Type Temperature°C Humidity %RH Size (litres)<br />

AES,LH-6<br />

ACS,CH160C Temperature & humidity chamber<br />

-70~180 20~95 178<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

-20~94 20~98 150<br />

ACS,CH340C -75-180 10-98 336<br />

LAb,OTWMD18<br />

30~200 66<br />

Laboratory oven<br />

MEM,ULE400 30~200 53<br />

TEN,TJR Temperature chamber -80~200 33.6<br />

ACS Trolley for CH160C Environmental Chamber<br />

ACS,<strong>TR</strong>OLLEY AU<br />

ACS Winkratos Software for CH160C Temperature & Humidity<br />

Chamber<br />

ACS,WINKRATOS AU<br />

Software for remote control of ACS,CH160C temperature and humidity<br />

chamber. Remote programming and control of chamber plus report<br />

generation. Includes Compaq Armada E500 pentium III 500MHz notebook<br />

computer & RS232C interface cable.<br />

Memmert ULE400 Laboratory Oven<br />

MEM,ULE400 AU<br />

Range 30~220OC. Capacity 53L, internal 400w x 400d x 330h mm. Two<br />

shelves. Electronic temperature control with max deviation of 0.8~4OC. Labec OTWMD18 Laboratory Oven<br />

LAb,OTWMD18 AU<br />

Fan forced laboratory oven, ambient to 200OC. Capacity 66L, digital<br />

temperature controller.<br />

Tenney TJR Environmental Temperature Chamber<br />

TEN,TJR AU<br />

Range -80~200OC. Workspace 400w x 280h x 300d mm. In transit case<br />

1350w x 720d x 1050h mm. Operates in case with lid off. Programmable<br />

controller 24 step display resolution 1OC. Heating rates 25~100OC, 15min<br />

or 25~200OC, 55min. Cooling rates 25~-40OC, 20min or 25~-80OC, 65min.<br />

Access port 50mmØ.<br />

AES LH-6 Temperature Humidity Chamber<br />

AES,LH-6 NZ<br />

Internal dimensions 610w x 510d x 480h mm. External dimensions 1170w x<br />

840d x 790h mm. Operating range temperature -20~94 O C, ±0.5 at sensor.<br />

Humidity 20~98%RH ±2% at sensor. Includes self contained humidity system,<br />

200 x 200mm window, access port, microprocessor controller and high/low safety<br />

shut down.<br />

GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 101


TEMPERATURE & HUMIDITY MEASUREMENT<br />

102<br />

temperature/humidity/barOmetric recOrderS<br />

Kane-May KM1242 5 Channel Indicator & Recorder<br />

KM,KM1242 AU<br />

Five channel temperature indicator and recorder. Range -100~1300 O C,<br />

resolution 0.1. Uses type K thermocouples. Gives average, max and min<br />

for period recorded. Operates from NiCd batteries or ac adaptor.<br />

Hanna HI98704, 4 Channel Thermocouple Printer<br />

HAN,HI98704 AU<br />

Four channel thermocouple input temperature display and printer. Accepts<br />

all common thermocouple types including K & T.<br />

Haenni KRK Thermohygrograph<br />

HAE,KRK501 MY<br />

Temperature -10~50ºC. Humidity 0~100%. Accuracy, thermograph ±1%fs,<br />

hygrograph: ±4%fs.<br />

temperature meterS/ir thermOmeterS<br />

Model Type<br />

RAY,Mx4+ IR thermometer laser sighted<br />

IR thermometer laser sighted plus digital<br />

RAY,Mx6<br />

camera<br />

Infrared thermometer with humidity probe and<br />

TES,845<br />

thermocouple probe<br />

> NEW Fluke 576 Photo Temp Infrared Thermometer with<br />

Built-in Camera<br />

FLU,576 AU/MY<br />

Range -30~900ºC. Minimum measurement 19mmØ, laser class II, 3 point<br />

spot. Includes adjustable emissivity from 0.1~1 by 0.01. Target size 1/60 of<br />

distance. Max, min, dif and av displayed on backlit lcd with bar graph. Data<br />

output USb or 1mV/ºC, windows software and cable included. Accuracy<br />

±0.75% of reading or ±1ºC which ever is greater. Response time 250ms.<br />

Display resolution 0.1ºC. Continuous measure mode.<br />

Micromech MM-01 Thermohygrograph<br />

MIC,MM01 AU<br />

Recording ranges -10~50 O C & 0~100%RH. Specify 7d or 24h charts.<br />

Hobo Pressure Logger<br />

HOb,pRES AU<br />

Range 0.5~16psia. Safe operating temp range -39~75 O C. Size 46w x 148d<br />

x 15hmm & 255g. Stores 1,800 measurements, 42 preset intervals. Data<br />

can be exported to spreadsheet. Logs in meters, feet, mbar and Hg. Battery<br />

life 2y.<br />

Dickson PR500 Pressure Logger<br />

DIC,PR500 NZ<br />

Records pressure in water and gas lines. Compact size is perfect for tight<br />

locations. Water resistant stainless steel case for use for outdoor applications.<br />

pressure range is 0~500pSI, accuracy is ±1% of full scale. Stores 7936 data<br />

points. Programming and data recovery done by TechRentals.<br />

Temperature<br />

Range ºC<br />

Output Ratio<br />

Type<br />

K<br />

Type J, T, E, N,<br />

R, S<br />

ANA,AN2406 Precision RTD thermometer -20~200 Serial & analogue RTD RTD<br />

FLU,52-2 Digital thermometer IR cxommunication port Yes<br />

FLU,54<br />

Logging with IR interface<br />

FLU,54-2<br />

RS232<br />

FLU,54Flukeview<br />

Dual channel digital logging thermometer -250~1,767<br />

IR interface & software<br />

FLU,54-2Flukeview Logging with IR interface USb<br />

FLU,576<br />

Photo temperature Infrared thermometer with<br />

built in camera<br />

2 Ch<br />

-30~900 USb or 1mV/ºC 60:1 No<br />

FLU,80pK3 Type K surface probe Probe<br />

FLU,80TK Type K transducer Analog out<br />

HAR,1521-NATA precision thermometer NATA -200~420 RS232<br />

MIC,M90H IR thermometer, high temperature range 600~3,000<br />

MIC,M90Z IR thermometer, narrow field of view -50~1,000<br />

-30~900<br />

Analog out & RS232<br />

-35~950 USb 75:1 Yes<br />

> NEW<br />

Fluke 52-2 Digital Thermometer<br />

FLU,52-2 MY<br />

Relative time clock on MIN, MAx, and AVG provides a time reference<br />

events. Electronic Offset function allows compensation of thermocouple<br />

errors to maximize overall accuracy . Measures J, K, T, & E-types of t/c.<br />

Readout in ºC, ºF, or Kelvin (K). battery life: typical 1000h. battery door<br />

allows easy replacement without breaking the calibration seal. Large backlit<br />

dual display shows any combination of T1, T2, T1-T2 plus MIN, MAx, or<br />

AVG. Additional t/c type R, S, & N (a total of 7 types). Recall function allows<br />

logged data to be reviewed on the display. IR communication port allows<br />

data to be exported to optional FlukeView Forms® Temperature pC software<br />

for further analysis and graphing. Data Logs up to 500 points of data with<br />

user adjustable recording interval.<br />

Yes<br />

180:1 No<br />

60:1<br />

Analog & USb 60:1<br />

1 Ch<br />

Yes<br />

No


NEW Testo 845 IR Thermometer With Humidity Probe and<br />

T/C Probe<br />

TES,845 AU<br />

Range -35~950ºC with built in humidity probe, range 0~100%RH.<br />

Switchable distance ratio far field 75:1 16mm, distance 1200mm, close<br />

focus 1mm, distance 70mm. Laser class II, 4 point spot/cross far field, 2<br />

point/1point close focus. Includes adjustable emissivity from 0.1~1, max,<br />

min, displayed on backlit LCD . Data output USb windows software and<br />

cable included. Accuracy ±0.75% of reading 100~950ºC. Display resolution<br />

0.1ºC. Continuous measure mode. plug in T/C probe supplied.<br />

Fluke 54 Dual Input TC with Logging<br />

FLU,54 AU<br />

Digital thermometer with data logging. Takes most t/c inputs. Accuracy<br />

±0.05% +0.3OC. Logging 500 points with date and time stamp. Records<br />

min, max or avg. Logged data can be reviewed on meter or downloaded via<br />

IR port (see FLU,54FLUKEVIEW).<br />

Fluke 54-2 Dual Input TC<br />

FLU,54-2 AU<br />

D series 2, dual input digital thermometer with data logging. Takes J, K, T,<br />

E, R, S, N T C inputs. Accuracy ±0.05%+0.3OC. 500 point logging with date<br />

and time stamp. Records min, max or avg. Logged data can be reviewed<br />

on meter or downloaded via IR port (see FLU,54FLUKEVIEW : Fluke 54 with<br />

IR/RS232 cable & Flukeview software or FLU,54-2FLUKEVIEW : Fluke 54-2<br />

with IR/RS232 cable & Flukeview software).<br />

Fluke 54 Dual Input TC with Flukeview Logging Software<br />

FLU,54FLUKEVIEW AU<br />

Specification as above. Logged data can be reviewed on meter or<br />

downloaded via IR port using cable and Flukeview software included.<br />

Fluke 54-2 Dual Input TC with Flukeview Logging Software<br />

FLU,54-2FLUKEVIEW AU<br />

Series 2, dual input digital thermometer with data logging. Will take most TC<br />

inputs. Accuracy ±0.05% +0.3ºC. 500 point logging with date & time stamp.<br />

Also records min, max or avg. Logged data can be reviewed on meter<br />

or downloaded via IR port RS232 interface, (using cable and Flukeview<br />

software included).<br />

Hart 1521 NATA Precision Handheld Thermometer<br />

HAR,1521-NATA AU<br />

Accuracy 0.025ºC. Includes 5614 probe ¼”Ø x 12” long. Calibrated in the<br />

-183~500ºC range. probe operating range -200~420ºC (cable and transition<br />

to 150ºC max).<br />

Analogic Precision RTD Thermometer<br />

ANA,AN2406 NZ<br />

Range -20~200ºC accuracy is ±0.1, resolution is 0.01. Supplied with a<br />

calibrated probe of 150mm x 6mmØ. Serial and analogue outputs. AC or<br />

battery operation.<br />

CHY 505 Portable Digital Reference RTD Thermometer<br />

CHY,505 NZ<br />

portable digital reference rtd thermometer. Range is -25~250ºC, resolution<br />

is 0.1, accuracy including probe ±0.05% of reading 0.3ºC. Supplied with<br />

pT385 RTD probe (length 150mm x 3mmØ) and IANZ endorsed calibration<br />

certificate.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

temperature meterS/ir thermOmeterS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Raytek MX4+ Infrared Thermometer<br />

RAY,Mx4+ AU/NZ<br />

Range -30~900 O C. Size of measurement target is indicated by lasers.<br />

Instrument includes Type K t/c for additional temperature measurement<br />

to set emissivity. Target size 1/60 of distance. built in emissivity table,<br />

audible/visible high low alarm. Max, min, dif and ave display. RS-232 and<br />

analog output, windows software and cable included. Accuracy ±1%, ±1 O C.<br />

Response time 250m/s. Display resolution 0.1 O C. Continuous measure<br />

mode.<br />

Raytek MX6 Photo Temp Infrared Thermometer, Built in Camera<br />

RAY,Mx6 AU/NZ<br />

Range -30~900ºC with built in digital camera. Min measurement 19mmØ,<br />

laser class II, 16 point circle spot. Includes adjustable emissivity from 0.1~1.0<br />

x 0.01. Target size 1/60 of distance. Max, min, dif and av display with backlit<br />

lcd with bar graph. Data output USb or 1mV/ºC, windows software and<br />

cable included. Accuracy ±0.75% of reading or ±1ºC which ever is greater.<br />

Response time 250m/s. Display resolution 0.1ºC. Continuous measure<br />

mode. Digital camera and flash built in.<br />

Micron M90H Infrared Thermometer<br />

MIC,M90H AU<br />

Range 600~3,000OC. Focusing 500mm to infinity. Field of view for<br />

measurement 1:180 ( 1 O O / ). Resolution 1 C. Accuracy 0.4% of reading.<br />

3<br />

Recorder output 1mV/ OC. RS232C interface. Battery operated.<br />

Mikron M90Z-B Infrared Thermometer<br />

MIC,M90Z AU<br />

Features through lens sighting and sharp focusing. Temperature displayed<br />

in view finder. Data hold, peak valley and average functions. Temperature<br />

range -50~1,000OC. Accuracy 1%, 1OC. Field of view for measurement<br />

1:180. Rechargeable NiCd batteries give 8h life.<br />

Fluke 80TK Thermocouple Module<br />

FLU,80TK AU<br />

Use with DVM’s and recorders. Accepts K thermocouples. Temperature<br />

range -50~1,000 O C. Output 1mV/ O C. Type 80Kp-1 probe included.<br />

TEMPERATUIRE & HUMIDITY MEASUREMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 103


TEMPERATURE & HUMIDITY MEASUREMENT<br />

104<br />

thermal imaging cameraS<br />

Marconi Argus2 Black & White Thermal Camera<br />

MAR,ARGUS2 AU<br />

Gives live thermal image, quick and clear image. Good for fast assessment.<br />

Applications include general industrial work, electrical work, surveillance<br />

work and termite inspection. Displays temperature in the centre of image.<br />

If the image needs to be recorded you can use the NOG,USbVIDEO or<br />

the Cannon MV400i and use the analog video in (The ARGUS2 video out<br />

is an NTSC signal). The accuracy of the temperature measurement is<br />

±2OC or ±2% and the range is 0~500OC ±2 or ±2%. Ambient temperature<br />

measurement is ±2OC or ±5%. Display indicates a temperature difference<br />

of 0.1OC. Uses the 0.8~14µm thermal range. Dust and water proof to Ip67.<br />

battery life is 120min per battery (4 supplied).<br />

ISI 525 Snapshot Thermal Camera<br />

ISI,IR777 AU/NZ<br />

Uncooled thermal imaging system with a 4” high resolution TFT LCD display<br />

which captures and stores an image to a pCMCIA card. A cursor on the<br />

display can be driven to any point on the image and a temperature at that<br />

point read out. Measurement range is 0~350OC. pAL video output. In-built<br />

pCMCIA card stores 72 images.<br />

External Battery Pack for ISI,IR777 Thermal Imaging Camera<br />

ISI,bATTpACK-ExT AU<br />

Optional sealed lead acid battery pack for ISI,IR777 Thermal Imaging<br />

Camera. battery capacity 10Ah, includes carry case for battery with shoulder<br />

strap, smartcharger and special connector with 2m of connection cable.<br />

> NEW<br />

Flir InfraCAM thermal Imaging Camera<br />

FLI,INFRACAM AU<br />

Simple to use battery operated real time thermal imaging camera. In-built<br />

3.5” colour LCD, detector resolution 120 x 120. Ranges, spectral 7.5~13µm,<br />

temperature -10~350ºC, accuracy ±2 or ±2% of reading. Imaging frame rate<br />

9Hz, video output via USb interface, stores 50 images. Down load to pC via<br />

USb. Operating range -15~50ºC. Supplied with Quickview s/w and digital<br />

camera. Fixed spot on LCD, maximum 3 spots via software.<br />

Flir Systems E45 ThermaCam Thermal Imaging Camera<br />

FLI,E45 AU<br />

In-built 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral<br />

7.5~13µm, temperature -20~250 O C, accuracy ±2 or ±2% of reading.<br />

Imaging frame rate 50Hz, video output standard RCA composite video,<br />

stores 200 images, image run or freeze. Download to pC via USb. Operating<br />

range -15~45 O C. Supplied with download software and Panasonic digital<br />

camera. Single moveable spot for temperature measurement. Built in tripod<br />

mounting, 1/4”-20.


SAT S160 Real Time Thermal Imaging camera<br />

SAT,S160 AU/NZ<br />

With 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral<br />

8~14µm, temperature -20~250 O C ±2 or ±2%. Imaging frame rate 50Hz,<br />

video output pAL, image storage 500 pictures, image run or freeze. Image<br />

download to pC via USb. Ambient operating range -15~50 O C. Supplied with<br />

download software and panasonic DMC-FZZA digital camera.<br />

Model Type Features<br />

pAN,pM880 Industrial Moisture Analyser Intrinsically safe<br />

pAN,MMS35 Moisture meter for air & nat gas Moisture content under pressure<br />

PRO,SM* Concrete & timber moisture meter Two pin inspection mode & RF mode<br />

PRO,CMIII* Concrete moisture meter Gel conductivity & standard surface humidity test<br />

*See Concrete Testing Equipment<br />

> NEW<br />

GE Panametrics PM880 Industrial Moisture Analyser<br />

pAN,pM880 AU<br />

Intrinsically safe moisture analyser for compressed air systems, noncorrosive<br />

gases & hydrocarbons such as natural gas (IS certification to<br />

ATEx and CSA). Displays dew point, moisture concentration, pressure &<br />

temperature. Dew point calibrated measurement range -80~20°C with data<br />

to -110°C. pressure range 7~69bar limited by sensor, gauge and safetyvalve<br />

(operating range from 5µHg). Temperature range -30~70°C. Gas flow<br />

operating range from static to 10,000 cm/sec velocity. Supplied with compact<br />

sample system with gauge, safety-valve, sampling valves and fittings (¼”<br />

Swagelok). Data logging of up to 100K moisture points, with infrared port<br />

and software for download. battery powered only (15-24h operation) with<br />

second battery and charger (note charger is not IS).<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

thermal imaging cameraS<br />

SAT Tripod Fitting Adaptor For SAT S160 Camera<br />

SAT,<strong>TR</strong>IpOD-FIT AU<br />

Tripod fixture clamps around the SAT,S160 thermal imaging camera and<br />

then allows this camera to be mounted on a tripod.<br />

humidity & mOiSture meterS<br />

Panametrics MMS35 Air/Natgas Moisture Analyser<br />

pAN,MMS35 AU<br />

Intrinsically safe for compressed air systems and hydrocarbons such as<br />

natural gas. Displays dew point & ppm moisture by volume. Pressure<br />

set as a constant. Data logging with RS232 port for download. Operating<br />

temperature range -110~70 O C. pressure range 5µHg~5,000psig. Accuracy<br />

60~-60 O C ±2, -66~-110 O C ±3. Repeatability: 60~-60 O C ±0.5, -66~-110 O C<br />

±1. Response time


SECURITY EQUIPMENT<br />

106<br />

Security equipment<br />

Detec DH50 Hand-held Metal Detector<br />

DET,DH-50 AU<br />

Simple to operate, no adjustment needed. Audible alarm.<br />

Detec DH50 Hand-held Metal Detector Kit of 4<br />

DET,DH-50-KIT4 AU<br />

Kit of 4 x hand held security metal detector. Simple to operate - no adjustment<br />

needed. Audible alarm.<br />

Garrett CS5000 Walk Through Metal Detector<br />

GAR,CS5000 AU<br />

Detects all metals. Requires assembly on-site & set-up. Adjustable<br />

sensitivity.<br />

Garrett Superscanner Hand-held Metal Detector<br />

GAR,SUpERSCANN AU<br />

For security applications.<br />

Swise Surveillance Digital Camera<br />

SWI,COLOR AU<br />

Captures up to 700 images. Includes motion detector, only takes images of<br />

changes. Can be connected to a modem to dial and transmit the images.<br />

Contact input which activates dialing so it could be connected to a DataTaker<br />

for dial out alarms. Includes software and cable to download the images<br />

to a PC directly or via a modem. Will not operate until powered. When<br />

finished, will not operate after power down. System can be configured and<br />

downloaded by <strong>TR</strong> Services (please request quotations). System draws<br />

120mA @ 12V, operates for 3d on 10Ahr 6V batteries, or for 6d on 8 alkaline<br />

D cells or 9d on 2 lantern batteries.<br />

AVE Serial to Video Converter Including Video Mixer<br />

AVE,VSIpLUS AU<br />

Mixes serial data (text) with video signal, so that a picture includes this text.<br />

Use with a GpS (eg GA,E<strong>TR</strong>Ex) to add a location reference to a video or<br />

used with cash register RS232 output to record transactions on a security<br />

camera picture.<br />

Elbex 1-Camera VCR Surveillance System<br />

ELb,CCTV2 AU<br />

Single camera time lapse video recorder. Uses pin hole camera and 24h time<br />

lapse VHS VCR. VCR can accept an alarm input from a motion detector, etc<br />

and this will provide a time stamp and trigger a period of real time recording.<br />

Camera lens 8.5mm giving 70O field of view. Video monitor included.<br />

Poptron CCD RF Camera and Receiver IR Lighting<br />

pOp,RF-CCD AU<br />

Video surveillance camera with radio frequency link. Transmits video &<br />

audio from a camera 30m~100m depending upon conditions (900~930MHz<br />

carrier). Standard video & audio output. Infrared illuminator included - range<br />

1.5m.<br />

Optalign RF Transmitter Detector System<br />

OpT,bUG AU<br />

Radio transmission detector system useful for ‘bug’ detection and nearby<br />

transmission interception. Comprises 3 principal units R10 FM interceptor<br />

which auto tunes to a near field transmitter - range 120m typical for 5W<br />

VHF/UHF. In-built speaker and deviation indicator. Frequency range<br />

30MHz~2GHz. R20 AM interceptor with headphone output. Frequency<br />

range 500kHz~2.5GHz. Signal strength bar graph. Scout 40 frequency<br />

counter for off air frequency indication of near field transmissions. In-built<br />

logging permits a walk through surveillance of an area. Accessory antennas<br />

are included to optimise reception. An optional pC package permits long<br />

term surveillance - see separate model.<br />

Optalign Optalog Scanning Software<br />

OpT,OpTOLOG AU<br />

pC interface and software for OpT,bUG Scout 40 frequency counter.<br />

Pacom 8 mm Colour Camera, Auto Iris, 6~15mm Lens<br />

CAM,COL-AUTO AU<br />

Colour surveillance camera 8mm CCD auto Iris 6~15mm lens.<br />

4 Camera Surveillance Digital Stand-Alone Record System<br />

CAM,DVMR-4C AU<br />

4 day/night colour cameras with stand-alone digital video multiplex recorder,<br />

complete system with 15” colour LCD screen, 20m connection cables, power<br />

supplies and video to USb coverter for down loading of data to pC.


did yOu knOW….<br />

We have Over<br />

10,000 itemS Of<br />

SpecialiSed<br />

technical<br />

equipment in Our<br />

inventOry, SO<br />

We’re bOund tO<br />

have a SOlutiOn tO<br />

virtually any teSt<br />

and meaSurement<br />

prOblem.<br />

tO See Our full<br />

range viSit Our<br />

WebSiteS and<br />

dOn’t fOrget<br />

tO regiSter fOr<br />

neW prOduct<br />

releaSeS tOO.<br />

www.techrentals.com.au<br />

www.techrentals.co.nz<br />

www.techrentals.com.my<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

metal detectOrS<br />

Pulse Technology AQ-1B Underwater Metal Detector<br />

pUL,AQ-1b AU<br />

Suitable for above ground use also. Hand-held, battery operated, complete<br />

with high sensitivity 15” search coil, compact 8” coil, and small ferrite probe.<br />

Supplied with a bone conduction phone for underwater use and headphones<br />

for above ground use. Complete with charger.<br />

Minelab SD2000 Gold Prospecting Metal Detector<br />

MIN,SD2000 AU<br />

Designed primarily for gold prospecting. Kit includes 2 search heads, battery<br />

and 240V and in-car battery chargers. Incorporates multi-period sensing<br />

(mps), allowing the unit to operate in highly mineralized soils (it will detect<br />

nuggets at 2~4 times the depth of a typical metal detector). battery life<br />

16h.<br />

Cscope CS550 General Purpose Metal Detector<br />

CSC,CS550 AU<br />

Simple to use and light weight. Ideal for locating rings, etc. Works well in<br />

locating metal underground services.<br />

Excaliber 1000 Under Water Metal Detector<br />

ExA,1000 AU<br />

MIN,Ex-1000 MY<br />

Search coil 10”. Use effectively in or out of the water. Features 2 operating<br />

modes all metal and discriminate. In discriminate mode, ignores most<br />

ferrous objects and still detects the valuable non-ferrous objects such as<br />

gold and silver. Rechargeable battery pack separated from the electronics<br />

cylinder allows easy access for recharging.<br />

retail traffic flOW cOunterS<br />

Traffic Pro People Counter Event Logger<br />

<strong>TR</strong>A,RETAILpACK AU<br />

Counts the number of people passing a particular point. Used to check the<br />

success of in-store promotions, counting people entering sections of a store,<br />

etc. The unit operates from internal batteries and will store one years worth<br />

of data at a 1h sample rate.<br />

SECURITY EQUIPMENT<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 107


did yOu knOW….<br />

tr cOrpOratiOn<br />

haS 30 lOcatiOnS<br />

acrOSS the aSia<br />

pacific regiOn,<br />

SO itS never been<br />

eaSier tO rent<br />

yOur teSt and<br />

meaSurement<br />

needS frOm uS.<br />

viSit Our WebSiteS<br />

fOr cOntact<br />

detailS.<br />

www.techrentals.com.au<br />

www.techrentals.co.nz<br />

www.techrentals.com.my


ENVIRONMENTAL


FLOW METERS<br />

110<br />

flOW meterS - liquid<br />

Model Type Features Max Flow Temp °C Pipe Ø mm Major Application<br />

pAN,pT868<br />

pAN,pT878<br />

Ultrasonic<br />

Transit time<br />

Non-contact<br />

Data logging<br />

RS232C<br />

4~20mA<br />

Data Logging<br />

IR interface<br />

Large LCD<br />

Global FP101 Digital Water Velocity Meter<br />

GLO,Fp101 AU<br />

portable flow probe - current meter for water velocity measurements in<br />

streams, channels and partially filled pipes. propeller sensor in 50mmØ<br />

housing, fitted to telescopic handle [1.8m] with gauging marks to 900mm<br />

depth. Digital LCD flowmeter display for instantaneous liquid velocity and<br />

average, maximum, stopwatch or clock. Minimum depth about 50mm.<br />

Range 0.1~4.5m/s ±0.05.<br />

Panametrics PT868 Ultrasonic Flowmeter<br />

pAN,pT868 AU/NZ<br />

portable non-contact liquid flowmeter using transit-time principle. Includes<br />

transducers for pipe diameters 50mm~2m and temperatures -20~150 O C<br />

[additional transducers available] with clamping fixture. Flow velocity range<br />

0.03~12.2m/s. Accuracy typically 1%. Data logging capacity. Analog [current<br />

loop] and RS232C outputs, and analog inputs compatible with temperature<br />

transmitters for energy-flow calculations. Totalised flow and trend analysis.<br />

Rechargeable NiCd operation for 8~10h or operation from ac mains or<br />

external dc 10~28V supply.<br />

~12m/s -20~150 50~2,000<br />

Liquids, Energy flow<br />

Low gas/solids content<br />

pipes (clamp-on)<br />

Note: NATA versions available<br />

pAN,C-Lp-40NM<br />

-40~120 12~50 Small diameter pipes<br />

pAN,C-pT-10Hb<br />

Transducer set,<br />

pT868/878<br />

-20~210 50~2,000 Wide temperature range<br />

pAN,OKS -200~400 80~600 Very wide temperature range<br />

pAN,2CHRT-1-1 Temperature sensors,<br />

-20~130<br />

pAN,2CHRT-1-2 pT868/878<br />

-20~260<br />

pAN,SOFTWARE<br />

Software PT868 &<br />

pAN,MMS35<br />

Ultrasonic<br />

Dual frequency<br />

pOL,HYDRA-Sx30<br />

Doppler<br />

Data logging 10m/s -40~122 12~5,000<br />

Non-contact<br />

RS232C, 4~20 mA<br />

UNI,6526b-21<br />

UNI,6526b-21LCD<br />

HYS,OSSb1<br />

Ultrasonic<br />

Doppler<br />

propeller flow counter with<br />

field-computer<br />

GLO,FP101 propeller flow counter<br />

Log rate 5s –1 week<br />

Flow/Depth/Temp<br />

Log rate 5s –1 week<br />

Flow/Depth/Temp<br />

LCD display<br />

Stainless fan<br />

Adjustable depth<br />

storage & download<br />

Telescopic handle<br />

Velocity averaging<br />

Digital counter<br />

~5m/s -0~60<br />

5m/s<br />

4.5m/s<br />

5cm min<br />

depth<br />

Clamp-on<br />

Storage, Recall, Download<br />

Liquids, Slurries<br />

High gas/solids content<br />

Pipes<br />

Liquids, Slurries<br />

Open Channel<br />

Logging System<br />

Water Current Measurements<br />

Hydrology<br />

Rivers & streams<br />

Irrigation channels<br />

Panametrics Software for PAN,PT868 & PAN,MMS35<br />

pAN,SOFTWARE AU<br />

Software for pAN,pT868 flowmeter and pAN,MMS35 moisture analyser.<br />

Allows storage, recall and download of instrument setup routines. Versions<br />

available to match instrument firmware revisions.<br />

Panametrics PT868 Flowmeter NATA Certification<br />

pAN,pT868-NATA AU<br />

Specification as for pT868 above but NATA certification.<br />

Panametrics 12~50mm Transducers<br />

pAN,C-Lp-40NM AU/MY<br />

Transducer pair for pAN,pT868/878 transit-time flowmeter to suit pipe<br />

12~50mmØ. Complete with CF-Lp-50M mounting bracket. Temperature<br />

range -40~120 O C.<br />

Panametrics -20~210OC Transducers<br />

pAN,C-pT-10Hb AU<br />

High temperature transducer pair for pAN,pT868/878 transit-time flowmeter.<br />

Operates on pipe sizes 50mm~2mØ. Working temperature range -<br />

20~210 O C.<br />

Panametrics -200~400OC Transducers<br />

pAN,OKS AU<br />

Very high temperature, wide range transducer pair for pAN,pT868/878 transittime<br />

flowmeter. Temperature range -200~400 O C, for pipe 80mm~600mmØ.<br />

Uses special clamp system supplied. Appropriate protection and safehandling<br />

equipment is required for fitting and operation at very high or low<br />

temperatures.


Panametrics PT878 Ultrasonic Flowmeter<br />

pAN,pT878 AU/MY<br />

portable non-contact liquid flowmeter using transit-time principle. Includes<br />

transducers for pipe 50mm~2mØ & temperatures -20~150 O C (various<br />

alternative transducers available) with clamping fixture. Flow velocity range<br />

0.03~12.2m/s. Accuracy typically 1%. Data logging for over 10K data<br />

points. Analog inputs compatible with temperature transmitters for energyflow<br />

calculations. Outputs analog 4~20mA, digital (pulse or frequency) and<br />

printer/computer (Infrared port). Large LCD display for velocity, volumetric<br />

and energy flow rate, totalised flow and trend data in alphanumeric and<br />

graphical formats. Rechargeable NiMH batteries and ac power supply/<br />

charger.<br />

GE Panametrics PT878 Flowmeter with NATA Certification<br />

pAN,pT878-NATA AU<br />

Specification as above but with NATA certification.<br />

Polysonics Hydra SX30 Dual Frequency Doppler Liquid<br />

Flowmeter<br />

pOL,HYDRA-Sx30 AU<br />

Ultrasonic non-contact flowmeter. Velocity range 0.06~10m/s, accuracy<br />

±1%. pipe size range 12mm~5mØ. Data logging for 90,000 points, with pC<br />

software and interface cable for download via RS232C interface. Transducer<br />

temperature range; -40~122 O C. Analog output 4~20mA. battery operated,<br />

12h continuous use [8h recharge].<br />

Hydrological Services Universal Current Meter OSS-B1<br />

HYS,OSSb1 AU<br />

Water current meter for measurement of flow velocity in rivers, streams,<br />

channels and open water. Robust streamlined stainless body fitted with high<br />

precision 100mmØ fan [flow range 0.025~5m/s]. Set of stainless wading rods<br />

for depths to 3m. Rechargeable “Hydromate” ruggedised field computer with<br />

Ip65 case. Storage of fan calibration formulae for direct readout of volumeflow.<br />

Touch screen entry for set up, input, storage and download. Supplied<br />

with PC download software and cable.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

flOW meterS - liquid<br />

Panametrics 2-CH RTD TX for PT868/878 Energy Calcs<br />

pAN,2CHRT-1-1 AU<br />

Two channel 4~20mA RTD transmitter, range -20~130OC for energy rate<br />

and consumption measurements with pAN,pT868 or pAN,pT878 ultrasonic<br />

flowmeters. Provides supply and return temperatures for flowing liquid.<br />

panametrics cable and connector supplied. Fitted with pair of clamp-on<br />

Pt100 RTDs and cables. Powered from flowmeter.<br />

Panametrics 2-CH TX for PT868/878 Energy Calcs<br />

pAN,2CHRT-1-2 AU<br />

Two channel 4~20mA RTD transmitter, range -20~260OC for energy rate<br />

and consumption measurements with pAN,pT868 or pAN,pT878 ultrasonic<br />

flowmeters. Provides supply and return temperatures for flowing liquid.<br />

panametrics cable and connector supplied. Fitted with pair of clamp-on<br />

Pt100 RTDs and cables. Powered from flowmeter.<br />

Unidata Open Channel Liquid Flow Logger with LCD module<br />

UNI,6526b-21LCD AU<br />

Open channel flow logger with field LCD display module and 10 m cable<br />

(2m depth rating). Measurement and logging of flow-velocity (by Doppler),<br />

depth (by pressure) and temperature. programmable for flow-channel<br />

profile (laptop pC required for in-situ programming via RS232C). Operating<br />

temperature range 0~60 O C. Velocity 21~5,000 mm/sec +/-2%; depth<br />

0~2,000 mm +/-2%. Temperature: -17~60 O C +/-0.1; log-interval 5 sec~1<br />

week; memory 120k. programmable output to control devices such as water<br />

samplers. Detects and measures reverse flows. Charger and batteries<br />

supplied. Workhead dimensions 290 x 70 x 25mm.<br />

Unidata Open Channel Liquid Flow Logger<br />

UNI,6526b-21 AU<br />

Open channel flow logger, programmed in-situ for flow-channel profile<br />

(laptop pC required). Measurement of flow-velocity (by Doppler), depth (by<br />

pressure) and temperature. Includes 10m cable. Memory 120k, RS232<br />

interface. Log rate 5 sec~1 week. Operating temperature range 0~60 O C.<br />

Velocity 21~5,000mm/sec +/-2% (resolution 1); depth 0~2,000mm +/-2%<br />

(resolution 2). Temperature: -17~60 O C (resolution 0.1). Programmable<br />

output to control devices such as water samplers. Detects and measures<br />

reverse flows. Charger and batteries supplied. Workhead size 290 x 70 x<br />

25mm.<br />

FLOW METERS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 111


FLOW METERS<br />

112<br />

flOW meterS - gaS<br />

Model Type Features Max Flow<br />

SpI,VFM5000-50 Vortex<br />

4 ~ 20mA output<br />

Flow, Pressure, Temperature<br />

HOF,2000 & HOF,38 Turbine flowmeter Totalising recorder outputs<br />

SIE,S100-5<br />

KUR,2443-24<br />

pVL,CLIMA3<br />

TSI,4143-6<br />

TSI,4040-6<br />

Mass-flow thermal<br />

sensor<br />

Thermal mass-flow<br />

insertion meter<br />

Insertion<br />

micro-turbine<br />

Mass-flow thermal<br />

sensor<br />

Mass-flow thermal<br />

sensor<br />

“Dial-A-Gas” for 10 gases<br />

RS232C, Analog outputs<br />

Cold tap fittings, RS232C<br />

Logging, 4 ~ 20mA output<br />

Hot-tap rig<br />

RS232, Pressure transducer<br />

Temp measurement<br />

RS232C, Mains/battery<br />

Temp measurement<br />

RS232C, Mains/battery<br />

ClimaAir 3 Flow Meter for Compressed Air & Gases<br />

pVL,CLIMA3 AU<br />

Portable gas flowmeter for compressed air and other applications. Fitted<br />

with “Combisensor” insertion probe for simultaneous measurement of flow,<br />

pressure and temperature. Measuring ranges flow 0.06~40m/s, pressure<br />

to 15bar, temperature to -20~80ºC. Supplied with valve and adaptor-kit for<br />

hot-tapped pipes approx 25~150mm ID, and fitting-kit for pipes to 450mm.<br />

Flow computer functions include flow correction, volume-calculation, and<br />

data logging for about 15,000 values. With RS232 interface and cable, and<br />

software for data download. Rechargeable with AC adaptor.<br />

Sierra Series 100 Gas Mass-flowmeter 0~5l/min<br />

SIE,S100-5 AU<br />

Smart-Trak mass flowmeter. Digital display of mass flow rate for gases<br />

in the range 0~5l/min. Dial-A-Gas set up for direct readout of flow for 10<br />

different common gases without adjustment or recalibration. Analog and<br />

serial RS232 ports, with software and cable provided for connection to PC.<br />

Portable configuration with case, battery, ac power supply and flexible gas<br />

connection set.<br />

Portable Mass Flowmeter & Calibrator 0~300 SLPM<br />

TSI,4040-6 AU<br />

Thermal mass flowmeter or field calibrator for operation in the range<br />

0~300SLpM (standard litres/min). LCD display for flow, temperature and<br />

pressure . Suitable for flow measurements on clean air, or for calibration<br />

checks on personal sampling pumps. Accuracy ±2%/0.05SLpM [whichever<br />

is greater] for air or oxygen [±3%/0.10SLpM for nitrogen or air-mixtures].<br />

Operating pressure range 50-199kpa absolute [approx 95kpa gauge]. With<br />

HEpA filter, adaptor and tubing. RS232C/analog connector with cables<br />

supplied. AC adaptor or battery operation.<br />

Temp<br />

°C<br />

pipe Ø<br />

mm<br />

600m 3 /h Supplied DN50<br />

~200ACFM<br />

(50mm)<br />

Major<br />

Application<br />

Air under pressure<br />

Saturated steam<br />

38mm or 50mm turbine Gases<br />

5slpm ¼” (at meter) Low – flow gases<br />

12,000sfpm -40~200 50mm~ Gases<br />

40m/s -20~80<br />

0.01~20slpm<br />

0~50<br />

~150mm<br />

(450mm without hot-tap)<br />

In-line 9.5mm<br />

~300slpm In-line 22mm ISO<br />

Compressed air<br />

Clean air flow<br />

Use as calibrator<br />

Clean air flow<br />

Use as calibrator<br />

Portable Mass Flowmeter & Calibrator 0.01~20 SLPM<br />

TSI,4143-6 AU<br />

Thermal mass flowmeter or field calibrator for operation in the range<br />

0.01~20SLpM (standard litres/min). LCD display for flow, temperature and<br />

pressure . For flow measurements on clean air, or for calibration checks on<br />

personal sampling pumps. Accuracy ±2%/0.005SLpM [whichever is greater]<br />

for air or oxygen (±3%/0.010SLpM for nitrogen or air-mixtures). Operating<br />

pressure range 50-199kpa absolute [approx 95kpa gauge]. With HEpA filter,<br />

adaptors and tubing. RS232C/analog connector with cables supplied. AC<br />

adaptor or battery operation.<br />

Hoffer 2000 Gas Flow Meter Indicator<br />

HOF,2000 AU<br />

Flow indicator/totalizer for use with flow transducers. Digital display with<br />

recorder outputs 0~10V, 4~20mA. RS232C interface. Operates from ac<br />

mains. Display of metric units with optional conversion factor.<br />

Hoffer 38mm Gas Flow Turbine/Transducer<br />

HOF,38 AU<br />

38mm MS flared gas flow turbine/transducer for use with HOF,2000.<br />

Volumetric flow rate range 1.75~120 actual cfm - gas type, pressure and<br />

temperature correction may be used for mass flow units such as SCFM,<br />

kg/min or L/s. Supplied with 38mm Table E Flanges. Approach pipe length<br />

380mm, exit pipe length 190mm.<br />

Kurz 2443 Air Velocity Meter<br />

KUR,2443-24 AU<br />

portable air velocity meter and flow-computer. Velocity range 0~12,000sf/min<br />

(60m/s) at pressures to approx 10bar (probe rated to 20bar). Temperature<br />

range -40~200OC with compensation. User selected English or metric units<br />

for velocity or mass-flow. Thermal sensor probe 9.5mmØ & 330mm long<br />

with sensor-shield, with compression fitting and nylon ferrules for probe<br />

removal or position adjustment in tapped pipe. Suitable for use in ducts or<br />

pipes, min pipe 50Ømm. Calibrated for air, and suitable for use with other<br />

non-hazardous gases. Recording of up to 1,500 data sets with time and<br />

date. Two analog 4~20mA outputs, and RS232C serial port for configuration<br />

upload and data download. Rechargeable NiMH batteries.


Model Type<br />

SHO,CFM88-3<br />

TSI,8373<br />

TSI,8370<br />

TSI,8371<br />

TSI,8375<br />

AIR,EDM2500<br />

DRU,DpI705<br />

HAL,EMA150<br />

Balometer<br />

Accubalance modular air<br />

balancing tool<br />

Manometer (electronic)<br />

Air Velocity<br />

m/s<br />

0.13~41<br />

depending on<br />

probe<br />

~14<br />

~28<br />

Flow<br />

l/s<br />

12~944<br />

air flOW meaSurement/air quality<br />

Max<br />

Temp O C<br />

15~1,000 60<br />

11~1,000<br />

Pressure Functions Notes<br />

±3735Pa diff<br />

135 kpa abs<br />

125 Pa<br />

500 Pa<br />

2,500 Pa<br />

Logging<br />

Logging<br />

Recorder output<br />

0~20 kpa Analog output<br />

Hood<br />

Pitot<br />

Velocity Matrix<br />

SHO,ADM-860 ~50 0.025~14,700pa With Velgrid<br />

TSI,8704 1.25~78.5 -1245~3735pa<br />

AIR,DM2<br />

DPM,TT370S 1.2~100<br />

Manometer (digital)<br />

DPM,TT570CL 10~100 10~100<br />

TSI,8704<br />

Logging<br />

RS232C<br />

±200kpa Recorder output<br />

pressure:<br />

199.9Pa<br />

1999Pa<br />

7.0kpa<br />

pressure:<br />

99.9Pa<br />

999Pa<br />

7.0kpa<br />

Logging<br />

RS232C<br />

Without Pitot tube<br />

Extendable Pitot Tube<br />

1.27~78.5 -1245~3735pa<br />

TSI,8705<br />

Differential Micromanometer<br />

Pitot Tube<br />

TSI,8710 10~100 3735Pa<br />

TSI,8345<br />

0.15~30<br />

TSI,8355 Anemometer (hot wire) 0.15~50<br />

TSI,8384 0.1~50 60<br />

TSI,8324<br />

AIR,AV2<br />

AIR,AV6<br />

SCH,MINI-2<br />

Anemometer<br />

(vane, 100 mm)<br />

Anemometer<br />

(vane, 22 mm)<br />

0.25~30<br />

0.3~40<br />

TES,450 Anemometer<br />

(vane, 16mm)<br />

0.4~40 130<br />

TES,445 0.4~60 140<br />

AIR,UA6<br />

0~50<br />

AIR,UA30<br />

Anemometer (ultrasonic)<br />

0~30<br />

93<br />

80<br />

Logging<br />

Max, Min &<br />

Sweep<br />

70 Analog output<br />

Logging<br />

RS232C<br />

HOB,PRES Pressure logger 75 500~110,000pa<br />

KUR,2443-24 Air Velocity Meter 0~60 200 10*/20bar<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

70<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Results<br />

averaging<br />

Min/Max display<br />

Logging<br />

Ma, Min & Mean<br />

Logging<br />

RS232C<br />

Logging<br />

Static Tip<br />

Pitot Tube<br />

Velocity Matrix<br />

Articulated telescopic extension<br />

NATA version available<br />

Telescopic probe<br />

Micro-vane probe<br />

Low flow turbulence<br />

Low flow turbulence<br />

Reads to 0.001 m/s<br />

Flow – computer<br />

With pipe-fittings*<br />

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 113


AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

114<br />

air flOW meaSurement/air quality<br />

Model Type<br />

TSI,8520<br />

Particle measurement<br />

Temp<br />

O C<br />

RH%<br />

CO<br />

ppm<br />

CO 2<br />

ppm<br />

NO<br />

ppm<br />

Dust & Aerosol Notes<br />

0.001~100mg/m 3<br />

0.1~10µ<br />

AbA,301 0.3~5µ<br />

TSI,8525<br />

TSI,8386A<br />

Ultra fine particle<br />

measurement<br />

Multifunction air quality<br />

meter<br />

TSI,8551 Indoor air quality monitor<br />

TSI,8554<br />

(multi-function)<br />

YES,205-5<br />

Multifunction air quality<br />

logger<br />

TES,645-1<br />

TES,645-2<br />

60 5~95<br />

50 5~95 500 5,000<br />

0.01 ~ 5x10 5 particles/cm 3<br />

0.02~1µ<br />

Logging<br />

TSI,8520-1 Outdoor enclosure<br />

Logging<br />

Logging, Wet bulb<br />

Dew point, Differential pressure<br />

Logging<br />

RS232C/Software<br />

50 5~95 200 10,000 300 Logging<br />

Humidity & dewpoint meter 120 2~98 Robust stainless probe<br />

CAS,MICROTHERM Area heat stress monitor * *<br />

Portable Smoke Generating Machine<br />

CSS,COLT4 AU<br />

portable smoke generator with variable smoke emission rate. Suitable for<br />

air flow visualisation, HVAC ductwork leak-testing, fire training and general<br />

work. pump-free operation with smoke fluid supplied from consumable<br />

aerosol cans or refillable containers [pump supplied for pressurisation].<br />

Manual or continuous operation and off-power facility. Maximum output 31<br />

cubic meters/min at 1.5m visibility. Operation for 18min from one can at<br />

maximum capacity.<br />

Airflow EDM2500 Electronic Manometer 0~2500 Pa<br />

AIR,EDM2500 AU/NZ<br />

pressure ranges 125, 500 & 2,500pa. Air velocity measurement using pitotstatic<br />

tube with ranges 14 & 28m/s. Supplied complete with pitot static tube,<br />

balancing valve, and tubing. Fitted with 1mA fsd recorder output. battery<br />

operated.<br />

Airflow DM2 Medium Pressure Manometer<br />

AIR,DM2 NZ<br />

Handheld medium pressure digital manometer. Suitable for positive,<br />

negative and differential pressure measuements. Displays readings in mBar,<br />

kpa & psi. Ranges are ±2,000mbar, 200kpa & 29.99psi. Resolution is 1 or<br />

0.1mbar & 0.1 or 0.01kpa. Accuracy on all ranges is 0.5% of reading. Serial<br />

interface for uploading stored results. Maximum stored readings during<br />

logging is 700. Analogue output of ±1V at 0.5mV per mbar.<br />

WBGT index, RH + Dewpoint<br />

*Air temp to 60º, Wet temp to 40º<br />

Globe temp to 120º<br />

> NEW<br />

TSI 8710 DP-CALC Differential Micro-Manometer<br />

TSI,8710 AU<br />

Micro-manometer for static or differential pressure, velocity, volumetric<br />

flow, atmospheric pressure and temperature. With statistical analysis,<br />

density correction, K factor and automatic actual/standard flow calculation.<br />

Differential pressure range ±3735pa. Velocity display to 78m/s (range<br />

depends on probe). Supplied with static tip, Pitot tube, velocity matrix and<br />

temperature probe. Datalogging (1,000 point) with RS232C interface and<br />

software. Rechargeable cells or AC adaptor.<br />

> NEW<br />

TSI 8705 DP-CALC Differential Micro-Manometer<br />

TSI,8705 AU<br />

Differential micro-manometer measuring differential pressure, velocity,<br />

average, volumetric flow, maximum and minimum. With static pressure<br />

calculations, density correction and K factor. pressure range -1245~3735pa.<br />

Velocity range 1.27~78.5m/s. Supplied with 200~980mm telescopic pitot<br />

tube. Datalogging (1000 point) with RS232C interface and software. Battery<br />

powered.


TSI 8704 DPCALC Micro Manometer<br />

TSI,8704 AU<br />

Measures differential pressure, velocity, average, volumetric flow, max & min.<br />

With static pressure calculations, density correction and K factor. Pressure<br />

range -1245~3735pa. Velocity range 1.25~78.5m/s. Extendable pitot tube<br />

20~980mm. Datalogging 500 point with RS232C interface and software.<br />

DPM TT370S Digital Manometer<br />

DPM,TT370S NZ<br />

Digital micromanometer with an extendable pitot tube kit. Dp ranges are<br />

199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s. Dp<br />

accuracy is 1% of reading +2 counts. Recorder output of 1mV per count.<br />

DPM TT570CL Digital Manometer NATA Certification<br />

DpM,TT570CL-NATA NZ<br />

Digital micromanometer with an extendable pitot tube kit. Dp ranges are<br />

199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s.<br />

Dp accuracy is 1% of reading +2 counts. built-in data logger holds 1,400<br />

readings.<br />

Druck DP1705 Manometer 0~20 kPa<br />

DRU,DpI705 AU<br />

Handheld digital manometer range 0~20kpa, accuracy 0.2 %. Displays all<br />

common engineering units.<br />

Shortridge ADM-860 Electronic Manometer<br />

SHO,ADM-860 AU/MY<br />

Electronic micro manometer for air balance and similar applications.<br />

Measures differential pressure, air velocity and temperature. Differential<br />

pressure range 0.0025~1,500mm wg. Velocity range 7.5~3,000m/min<br />

(750m/min with velgrid). Memory 100 point with sum and average.<br />

Accessories include pitot tube and 16 point velgrid for face velocity work<br />

including exhaust hoods, clean room outlets, and large filters or coils.<br />

Airflow 36 Pitot Tube<br />

AIR,pITOT-36 AU<br />

pitot tube (36”) for use with manometers and micro manometers.<br />

Kurz 2443 Air Velocity Meter<br />

KUR,2443-24 AU<br />

portable air velocity meter and flow-computer. Working velocity range<br />

0~12,000 sf/m (60m/s) at pressures to approx 10bar (probe rated to 20bar).<br />

Temperature range -40~200OC with compensation. Selectable English<br />

or metric units for velocity or mass-flow. Thermal sensor probe 9.5mmØ<br />

x 330mm long with sensor-shield. Compression fitting and nylon ferrules<br />

for probe removal or position adjustment in tapped pipe. Suitable for use<br />

in ducts or pipes, min pipe 50mmØ approx. Calibrated for air and suitable<br />

for use with other non-hazardous gases. Recording of up to 1,500 data sets<br />

with time and date. Two analog 4~20mA outputs, and RS232C serial port for<br />

configuration upload and data download. Rechargeable NiMH batteries.<br />

TSI 8370 Accubalance Balometer<br />

TSI,8370 MY<br />

balometer including 5-hood kit and hard case. Flow range 15~1,000 litres/<br />

sec (50 to 3,500m3/hr) accuracy +/-5%, reading +/- 2.4 l/s (8.5m3/hr).<br />

Operating temp range 0-60OC. Weight (610 x 610mm hood) 3.4 kg hood<br />

provided 610 x610mm (standard), 610 x 1220mm, 305 x 1220mm, 305 x<br />

1525mm and 915 x 915mm.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

air flOW meaSurement/air quality<br />

TSI 8371 Accubalance Balometer<br />

TSI,8371 NZ<br />

Airflow hood 610 x 610mm. Measures air volume flowing through registers,<br />

diffusers, and grilles. Range is 15~1,000l/s, accuracy is ±5%. Temperature<br />

range is 0~60ºC. Sample and hold function displays reading of one sample.<br />

Automatic conversion between actual and standard flows when user initially<br />

inputs temperature and barometric pressure, variable time constant modes<br />

available for a steady display when measuring fluctuating flows, K factor<br />

function enables flexibility for measuring a variety of diffusers, back-lit display<br />

is easy to read in poor lighting conditions.<br />

TSI 8373 Balometer With Logging<br />

TSI,8373 AU<br />

Flow range 15~1,000L/s (50~3,500m3 /hr); accuracy ±5% [to ±2.4L/s].<br />

Operating temperature range 0~60OC. Includes 5 hood kit & hard case.<br />

Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,<br />

305 x 1,525mm & 915 x 915mm.<br />

TSI 8375 Accubalance Modular Air Balancing<br />

TSI,8375 (NZ)<br />

Balometer with detachable micromanometer for air balancing applications.<br />

610 x 610mm air capture hood for measurements in the range 42~4,250m3/<br />

h with automatic compensation for barometric pressure and air temperature,<br />

450mm pitot probe (range 0.13~41m/s), 16-point velocity matrix probe<br />

(0.13~13m/s) and static pressure probes (differential pressure range<br />

±3,735pa with safe limit 37kpa, absolute pressure range 47~135kpa).<br />

Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit<br />

LCD display for single or statistical readings with min, max and average of<br />

up to 1,000 values of each measured parameter. Manual result storage or<br />

automatic data logging up to 1,000 time/date stamped readings. RS232 port<br />

for data transfer to pC or serial printer, with cable and “LogDat” download<br />

software. Rechargeable with approx 12h operation, or ac adaptor.<br />

Shortridge CFM88-3 Electronic Balometer<br />

SHO,CFM88-3 AU<br />

Measures supply and exhaust flow in cfm and l/sec. Ranges 25~2500cfm<br />

supply and 25~1500cfm exhaust. Compensated for air density and back<br />

pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.<br />

Airflow AV2 100mmØ Anemometer with Volume display<br />

AIR,AV2 AU/NZ<br />

Vane anemometer with 900mm (35”) telescopic probe extension. Velocity<br />

measurement range 0.25~30m/s (50~6,000ft/min). Averaging mode<br />

available. Volume display based on duct or other area. Head operating<br />

range -10~70OC (lower limit of -30CC for short periods). Output 0~1V.<br />

Airflow AV2 100mmØ Anemometer NATA Certification<br />

AIR,AV2-NATA AU<br />

Specification as above but with NATA certification.<br />

Airflow AV6 100mmØ Anemometer with Volume<br />

AIR,AV6 NZ<br />

Vane anemometer 100mmØ with articulating extension handle. Measures<br />

velocity, volume flow and temperature. Vane head operating range is -<br />

10~70ºC, -30 possible for short periods. Accuracy is ±1% of reading +1<br />

digit. Resolution is 0.01 m/sec. Velocity range is 0.25~30m/s. RS-232C<br />

interface for data logging & real time data retrieval. Stores up to 99 readings<br />

of velocity & temperature. Analogue output of 0~1v.<br />

Schilknecht Mini Air 2 Vane Anemometer<br />

SCH,MINI-2 AU<br />

probe 22mmØ. Range 0.3~40m/s. Min, max & time averaging functions<br />

with 0~1V analog output.<br />

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 115


AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

116<br />

air flOW meaSurement/air quality<br />

> NEW<br />

Testo 445 Vane Anemometer with 16mm vane<br />

TES,445 AU<br />

Micro-vane probe. Simultaneous digital display of air velocity and<br />

temperature, with continuous-update, max, min & mean functions. Volumeflow<br />

option with entry of duct dimensions .Telescope mounted metal probe,<br />

vane 16mmØ. Operating range 0.4~60 m/sec, accuracy ±0.2m/s, ±1%mv<br />

up to 40m/sec. Temperature range -30~140ºC for short-term measurements.<br />

Selectable site-locations, and 3,000 point internal memory for manual saving<br />

or automatic data logging. Battery powered.<br />

Testo 450 Vane Anemometer with 16mm Vane<br />

TES,450 AU<br />

Anemometer with micro-vane probe. Digital display of air velocity and<br />

temperature. Telescope mounted metal probe, diameter 16mm. Operating<br />

range 0.4~40m/s ±0.2 and to 60m/s ±unspec. Temperature range -<br />

30~140 O C for short-term measurements. battery powered.<br />

TSI 8345 Hot Wire Anemometer<br />

TSI,8345 AU<br />

Thermal anemometer range 0.15~30m/s; accuracy ±3%; volumetric<br />

flow display; averaging capability up to 255 readings. Probe operating<br />

temperature range -17.8~93.3 O C. probe 98mm long x 6mmØ at tip. Digital<br />

display. RS232C printer interface. Battery or mains operation.<br />

TSI 8355 Hot Wire Anemometer<br />

TSI,8355 MY<br />

Range 0.15~50m/s. probe will operate over a temp range of -17.8~93.3ºC.<br />

Digital display with averaging capability o up to 255 reading. Temperature<br />

measurement range -17.8~+93.3 C RS 232 printer interface. battery & AC<br />

operation.<br />

TSI 8384 Hot Wire Anemometer<br />

TSI,8384 NZ<br />

Handheld hot wire anemometer. Velocity range is 0.1~50m/sec, accuracy<br />

is ±3% of reading or ±0.015m/s whichever is greater. Resolution is 0.01<br />

m/s. probe temperature range is -10~60ºC and 0~80%RH. Stores 1,394<br />

samples of velocity, volumetric flow-rate and temperature with time and date<br />

stamping. Data can uploaded to a pC or printed. Supplied with 10mmØ x<br />

1m telescopic probe.<br />

> NEW TSI 8324 VelociCalc 100mm Vane Anemometer with<br />

Volume Display<br />

TSI,8324 AU<br />

Vane anemometer with 100mm head, supplied with handle and 900 mm<br />

articulated telescopic extension. Velocity measurement range 0.25~30 m/<br />

s ±1%; temperature measurement range 0~80ºC ±0.5 ºC. Volume display<br />

range 0~4.36x106m3/h with input for circular or rectangular duct dimensions.<br />

Variable time-constant; sample statistics average, max and min; and “sweep”<br />

mode for extended continuous sampling. Internal memory for single point<br />

measurements or time-based data logging, for up to 2849 samples and 1000<br />

test IDs, with serial interface, cable and software for data download. Direct<br />

data acquisition [polling] from PC terminal modes. Battery powered with<br />

auto-power-off, and optional AC adaptor.<br />

TSI 8386A VelociCalc Air Conditioning Efficiency Meter<br />

TSI,8386A AU<br />

portable efficiency measurement system for HVAC and related work, with<br />

hot wire anemometer, static and differential pressure, temperature and<br />

humidity measurement with heat flow efficiency calculation. Velocity (hot<br />

wire) 0~50m/s, accuracy ±3.0%. Temperature -10~60OC, accuracy ±0.3.<br />

Wet bulb temperature 5~60OC. Relative humidity 0~95%RH, accuracy ±3%.<br />

Dewpoint -15~49OC. Static/differential pressure -1,245~3,735pa, accuracy<br />

±1%. probe length 100cm, tip diameter 7mm, base diameter 10mm.<br />

Includes data logging and printing. Battery operated.<br />

Airflow UA30 High Resolution Ultrasonic Anemometer 0~30m/s<br />

AIR,UA30 AU/NZ<br />

precision anemometer range 0~30m/s, accuracy better than 1% of reading,<br />

resolution 0.001m/s, non-directional. Temperature range 0~70OC, accuracy<br />

1OC, resolution 0.1OC. Flow turbulence range 0~99%. Capable of measuring<br />

very low air velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up<br />

to 99 readings of velocity, temperature and turbulence, intervals 1s~99min.<br />

RS232C interface. Operates for 20h on alkaline batteries.<br />

Airflow Ultrasonic Anemometer 0~50m/s<br />

AIR,UA6 AU<br />

Range 0~50m/s, accuracy better than 1% of reading, resolution 0.01m/s,<br />

non-directional. Temperature range 0~70 O C, accuracy 1 O C, resolution<br />

0.1 O C. Flow turbulence range 0~99%. Capable of measuring very low air<br />

velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up to 99<br />

readings of velocity, temperature & turbulence, intervals 5s~99min. RS232C<br />

interface. Operates for 20h on alkaline batteries.


NEW<br />

Testo 635-2 Humidity, Temperature & Dewpoint Meter<br />

TES,635-2 AU<br />

portable humidity meter fitted with robust stainless probe with sintered filtercap<br />

for general or duct measurements to 120ºC, and fast-action K-type<br />

surface temperature probe. Displays relative humidity, absolute humidity,<br />

dew point, degree of humidity, enthalpy, temperature, and differential<br />

temperature (dewpoint~surface). Operating range 2~98%RH (±2%). Air<br />

temperature -20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1).<br />

Internal memory for 10,000 values with USb interface, cable and software<br />

for download and presentation. Battery operated.<br />

Testo 635 Humidity & Dewpoint Meter<br />

TES,635 NZ/MY<br />

Temperature, humidity and dew point meter. Probe temperature range is<br />

-20~70ºC. Humidity range is 0~100%RH resolution: 0.1%, accuracy is ±2%.<br />

Dew point range is -50~40ºC.<br />

Testo 645 Humidity & Dewpoint Meter<br />

TES,645-1 AU<br />

portable humidity meter fitted with robust stainless probe for ambient work or<br />

duct measurements to 120OC. Displays relative humidity, absolute humidity,<br />

dew point, degree of humidity, enthalpy and temperature. Operating range<br />

2~98%RH [±2%], -20~120OC [±0.4/0.5]. battery operated.<br />

Abacus Hand-held Airborne Particle Counter<br />

AbA,301 AU<br />

Portable particle measuring system typically used in clean room applications.<br />

4 x fixed size channels 0.3, 0.5, 1.0 & 5.0micron. Count data automatically<br />

stored in a 500 sample memory which can be downloaded to a PC.<br />

Selectable sample time. Includes zero count filter for checking backgrounds.<br />

When used with included software will check clean rooms to ISO 14644 and<br />

BS5295 requirements. Battery operated.<br />

Vaisala WAA151 Wind Speed/Direction Transducer<br />

VAI,WAA151 AU<br />

Range 0.4~75m/s. Current output with selectable ranges including 4~20mA<br />

& 0~20mA. Requires indicator module such as DE,DT600 datalogger for<br />

indication of windspeed and direction.<br />

TSI 8551 Indoor Air Quality Monitor with Logging<br />

TSI,8551 AU<br />

Measures temperature, humidity, CO & CO concentrations. Humidity<br />

2<br />

5~95%RH, CO 0~500ppm, CO 0~5,000 ppm. Internal logging up to 63,000<br />

2<br />

data points; interval adjustable 1s~1h; RS232C interface and software<br />

included. Battery or mains operation.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

air flOW meaSurement/air quality<br />

TSI Q-Trak plus Indoor Air Quality Monitor with Logging<br />

TSI,8554 AU/NZ<br />

Indoor air quality (IAQ) monitor for temperature and humidity measurements,<br />

CO and CO 2 concentrations. Humidity range 0~95%, temperature range<br />

0~50 O C. Electrochemical cell for CO 0~500ppm. NDIR cell for CO 2<br />

0~5000ppm. Data logging for 48,671 data points with interval adjustable<br />

1s~1h. Fitted with RS232 interface, and software included for download,<br />

storage and reporting. Battery or mains operation with ac adaptor.<br />

YES 205-5 Indoor Air Quality Monitor with Logging<br />

YES,205-5 AU<br />

5 channels for temperature, humidity, CO2, CO & NO. Temperature range<br />

0~50OC, resolution 0.1, accuracy ±0.5. Humidity 5~95 %RH, accuracy<br />

±2%. CO2 0~10,000 ppm, resolution 0.5ppm. CO 0~200 ppm, resolution<br />

0.5ppm. NO 0~300 ppm, resolution 0.5ppm. Logging of CO and NO allows<br />

checking of indoor air for contamination by vehicle emissions from nearby<br />

carparks, loading docks etc. Includes interface and software. Mains/battery<br />

operation.<br />

Casella Microtherm WBGT Area Heat Stress Monitor<br />

CAS,MICROTHERM AU<br />

portable area heat stress WbGT monitor with real-time graphical display.<br />

Measures heat stress potential [WbGT index] according to ISO7243. pRTD<br />

sensors with internal calibration-reference for wet-bulb, dry-bulb and globe<br />

temperatures. Large LCD display for numerical or graphical indication of<br />

temperatures and processed values for WbGT [indoor/outdoor plus TWA],<br />

relative humidity and dewpoint. Simple keypad/menu setup. Data logging<br />

for up to 32 separate runs and 49,100 records, with interval 30s~1h. RS232C<br />

port with included PC software for download and reporting or realtime<br />

display. Low water-level warning, and settable audible/visible WbGT alarm.<br />

Handheld, free-standing or tripod-mount. battery operated.<br />

TSI 8520 DustTrak Airborne Particle Monitor<br />

TSI,8520 AU/NZ<br />

Portable aerosol monitor. Laser photometer with 90O scattering detection,<br />

Range: 0.001~100mg/m3 [Calibrated for A1 test dust, ISO 121203-1],<br />

resolution: 1% of reading or 0.001; particle size range: 0.1~10µm. Internal<br />

pump flow rate 1.4~2.4L/min (1.7 nominal). Data logging 30,000 data points<br />

(21d @ 1min), log interval: 1s~1h. RS232C interface and software included.<br />

Battery operated.<br />

TSI 8520-1 Environmental Enclosure for DustTrak<br />

TSI,8520-1 AU<br />

Weatherproof outdoor housing for TSI,8520 aerosol monitor. Rugged case<br />

with tripod mount, fitted with sample inlet and water trap. Includes extendedlife<br />

battery pack and charger/adaptor.<br />

TSI 8525 P-Trak Ultrafine Particle Counter<br />

TSI,8525 AU<br />

Range 0.01~5 x 105 particles/cm3 . particle size range 0.02 to greater than<br />

1micron. Includes PC software and cable. Suitable for detection of ultrafine<br />

particles associated with pollutants. Battery powered [8h operation using<br />

alkaline batteries].<br />

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 117


AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

118<br />

air cOnditiOning balancing inStrumentS<br />

> NEW<br />

Testo 560-2 Electronic Manifold for Refrigeration Testing<br />

TES,560-2 AU<br />

Three-way valve bank, for commissioning, maintenance and repair<br />

of refrigeration systems. Stainless-steel block for use with common<br />

pressure media including CFC, FC, N, CO and ammonia; with stored<br />

2<br />

data (including saturation properties) on 36 refrigerants. Measurement of<br />

vacuum (0~200hpa), pressure (0-50bar), ambient [case] temperature for<br />

compensation (-10~50ºC) and system temperature (-100~400ºC instrument<br />

range; supplied with pipe-wrap probe 0~120ºC). Calculations for absolute/<br />

relative pressure, vacuum drying-efficiency, system cooling/heating capacity,<br />

leakage testing, superheating or sub-cooling values. Data storage, or<br />

interval-logging up to 100,000 readings, with serial interface and software<br />

for download, analysis and documentation. battery or AC adaptor powered.<br />

leakage detectOrS<br />

Haloteck Refrigerant Gas Leak Detector<br />

HAL,78000 AU<br />

For use by refrigeration engineers. Rapid response 0.2s, audio output,<br />

zero warm up time. Single control, battery operated, sensor tip insensitive<br />

to draughts. Sensitivity better than 3g/y R12, 25g/y R134A. Responds to<br />

halogenated hydrocarbons and many fire extinguishant gases, [also sulphur<br />

hexafluoride SF6]. Battery life 30h. Duty cycle continuous. Probe length<br />

240mm. Weight 280g.<br />

Bacarach Leakator 10 Combustible Gas Leak Detector<br />

bAC,LEAK10 AU<br />

Flexible probe with solid-state sensor for rapid area checks and pinpointing<br />

of large or small leaks. Sensitive to combustible vapours including common<br />

solvents, and gases including natural gas. Adjustable sensitivity with<br />

detection limit approximately 20ppm [methane]. Indication by ultra-bright<br />

LEDs and audible speaker. battery powered.<br />

Weather StatiOnS<br />

> NEW<br />

Environdata WeatherOne Wind Speed & Direction Logger<br />

ENV,DL20WSD AU<br />

Logging system for wind speed and direction. Tripod-mounted cross-arm<br />

stand with 3-cup windspeed sensor range 0-75m/s and independent vane<br />

direction sensor. Sealed dual-channel logger with memory for 35,000<br />

readings with time and date, fitted with backup battery, rechargeable sealed<br />

main battery and solar panel for in-field recharge. power supply for charging<br />

or operation from mains supply. “EasiAccess” software on CD for office or<br />

field connection via RS232C compatible computer (not included), for setup,<br />

download and real-time operation, with functions for tabular or graphical<br />

display.<br />

Tour & Anderson CBI Balancing Meter<br />

TA,CbI AU<br />

Digital pressure balancing instrument with LCD display. For cooling water<br />

valve balancing in air conditioning plants and similar applications. Firmware<br />

revision 3A. Includes facility for entry of Kv value to allow balancing of all<br />

hydronic valve types. Differential pressure range -0.5~20.5m water gauge<br />

at a total pressure of less than 200m. Resolution 0.001m. Flow resolution<br />

0.001L/s. battery operated.<br />

GasCheck 3000 Portable General-purpose Leak Detector<br />

ION,GASCHECK3000 AU<br />

Micro thermal-conductivity sensor for high-sensitivity detection of gases<br />

with a thermal conductivity different to that of air, including helium, carbon<br />

dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups.<br />

Direct reading of leak rate in ml/sec with audio and visible signals. Detection<br />

limit for helium 2E-5ml/s. battery powered.<br />

Environdata WeatherMaster 2000 Weather Station<br />

ENV,WM20 AU<br />

Measures air temperature -15~50 O C ±0.2, relative humidity 10~90%RH<br />

±5%, rainfall 0.2mm resolution. Wind speed starting threshold 1kph. Wind<br />

direction resolution 6 O ±3%. One spare input channel. Capable of storing<br />

up to 3mths of data. Includes RS232 interface and software for download.<br />

Mounts on star-picket. Solar-rechargeable batteries.


Hioki Lux HiTester Digital Illuminance Meter<br />

HIO,3423 AU/MY/NZ<br />

HIO,3423-NATA NZ<br />

Manual switching and autoranging. LCD display with 3½ digits (“1999”) for<br />

five measuring ranges to 20/200/2000lx in 1-count steps, 20,000lx in 10count<br />

steps and 200,000lx in 100-count steps with accuracy ±4%. Response<br />

time in autorange mode 5sec (2sec in manual range mode). Autozero, hold<br />

and backlight function with delay for taking readings in low light. Input for<br />

ac power adaptor, connecting-cable to allow separation of sensor unit and<br />

meter, and 200mVdc analog output with cable. Battery powered.<br />

Extech Digital Light Meter Nata<br />

ExT,407026 NZ<br />

NATA calibrated portable digital light meter. Ranges; 2,000, 20,000 & 50,000<br />

lux. Accuracy is ±4%. Displays in foot candles or lux for tungsten, daylight,<br />

fluorescent, sodium or mercury lamps. Data logging of measured values,<br />

Min/Max & Average, software and serial interface for uploading results.<br />

Minolta T-1 Lux Meter<br />

MIN,T-1 NZ<br />

Microprocessor controlled digital light meter. Measuring time can be<br />

adjusted for accurate readings of both continuous and flickering light<br />

sources. Illuminance deviation between sources can also be determined,<br />

or integrated illuminance over a period of time can be calculated. Range is<br />

0.01~99,900lx. Accuracy is ±2%.<br />

ILI 1400ABC Radiometer for UV Measurements<br />

ILI,1400AbC AU<br />

International Light model 1400 radiometer with backlit LCD display, autozero<br />

and autoranging. Continuous reading with hold function, or integrated “dose”<br />

measurement up to 24h. Smart detectors with storage of units and detectorcalibration<br />

data. Analogue recorder output. Mains adaptor or battery power.<br />

Supplied with three sensors: UV actinic hazard (UVC with b & A components<br />

matched to OSHA requirements), range 2.50e-7 to 2.50e-3 W/cm2 eff. UVb<br />

+ A (total “solar” radiation), range 1.16e-7 to 4.07e-1 W/cm2. UVb, range<br />

1.54e-6 to 1.54e-2 W/cm2.<br />

light & uv meaSurement<br />

Minolta CL-200 Chroma Meter for illuminance & Colour<br />

Measurement<br />

MIN,CL200 AU<br />

Konica Minolta model CL-200 portable colour meter. LCD display for<br />

illuminance, tristimulus values, chromaticity, correlated colour temperature<br />

and colour difference. Illuminance range 0.1~99,990lx ±2%. Colour accuracy<br />

±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface. battery powered,<br />

or AC adapter.<br />

Topcon BM-9 Luminance Meter<br />

TOp,bM-9-2 AU<br />

portable luminance meter with digital display. Field-of-view 5O , measurement<br />

acceptance angle 2O , with 10mm min spot diameter. Measuring distance<br />

0.35m to infinity. Silicon photodiode sensor with automatic or manual range<br />

selection. Measurement range 0.01~199,900cd/m2 ±4% of reading. built-in<br />

RS232C interface and analogue output. Battery powered.<br />

Topcon IM-2D Digital Luxmeter<br />

TOp,IM-2D AU<br />

Digital illuminance meter. Measuring range from 0.1~19,999lx. Accuracy<br />

±5%, +1 digit. Autoranging with silicon sensor. battery operated.<br />

Topcon IM-2D Lux Meter NATA Certification<br />

TOp,IM-2D-NATA AU<br />

Digital illuminance meter with NATA certification. Measuring range from<br />

0.1~19,999lx. Accuracy 5%, ±1 digit. Autoranging with silicon sensor.<br />

Battery operated.<br />

Topcon IM-5 Lux Meter NATA Certification<br />

TOp,IM-5-NATA AU<br />

Digital wide-range illuminance meter with NATA certification. Measuring<br />

range 0.01~199,000lx. Accuracy ±2% +1 digit. Autoranging with silicon<br />

sensor. Analog output and RS232 interface. battery operated.<br />

SOund Signal analySiS<br />

HP35660A 100kHz Dual Channel Spectrum Analyser<br />

Hp,35660A AU<br />

401 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal<br />

sources: fixed sine, random noise, chirp. built-in disk drive. HpIb plotter interface. bandwidth is 102.4kHz for single channel measurements and 51.2kHz<br />

for dual channel measurements.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

OCCUPATIONAL HEALTH & SAFETY<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 119


OCCUPATIONAL HEALTH & SAFETY<br />

120<br />

nOiSe & SOund analySerS<br />

Model Description Type/Class Features RS232C Major Applications<br />

bK,4443 Noise dosemeter (2) built-in set up routines, 53,000 values<br />

bK,2237A<br />

RIO,NL-04 2<br />

ac & dc outputs<br />

RIO,NL-11Fp Octave filter,printer<br />

Sound level meter<br />

RIO,NL14 1/1 octave filter, ac & dc outputs Yes<br />

> NEW<br />

ARL EL-316 Environmental Noise Logger Type 1<br />

ARL,EL-316 AU<br />

Environmental noise logger with display for field-reading of summary results.<br />

portable, self-contained and weatherproof. Type 1 performance, continuous<br />

90db dynamic range, fast response, frequency weightings A and C. Monitors<br />

environmental noise continuously for up to 3 weeks, calculates and stores<br />

over 7500 sets of Ln indices. PC required to set up system and download<br />

data using software supplied. Set up also possible from front-panel.<br />

40 data records, ac output<br />

bK,2237A-NATA NATA certificate, ac output<br />

RIO,NL05 Recorder outputs<br />

> NEW<br />

Ivie IE-35 Type 1 Audio Analysis Systems<br />

IVI,IE35-2p AU<br />

Audio Analyser with Dell Axim x51v pDA. Fitted with half-inch free-field<br />

Type 1 microphone and pre-amplifier. Functions include SpL (sound level),<br />

Real-time analysis, “seat-to-seat” variation for audio setup, reverberation<br />

measurement, “strip-chart” recording on display, voltage and oscilloscope<br />

displays and signal generation. Supplied with field-calibrator, microphone<br />

extension cable, spare battery and software for data-download to pC. SpL<br />

facilities include time and frequency weightings - fast, slow, peak or impulse<br />

and A, C or Flat. FFT based Real Time Analysis includes 1/1, 1/3, or 1/6<br />

octave bands with a maximum resolution of about 1/24 octave. Additional<br />

functions include spectrum subtraction, averaging, Noise Critera or Reduction<br />

contours and reverberation-decay to ISO-20 and ISO-30. Signal-generation<br />

includes sine, square, triangle and white or pink noise.<br />

Yes<br />

OH&S<br />

OH&S<br />

General<br />

QUE,2400 ac & dc outputs General<br />

bK,2239A-NATA<br />

NATA certificate, ac output Yes<br />

RIO,NL14-NATA 1/1, 1/3 octave filter, NATA certificate<br />

RIO,NL31 1<br />

1/1, 1/3 octave filter<br />

RIO,NL-32RTA-NATA<br />

bK,2238E-NATA<br />

NATA certificate, Data logging<br />

Realtime frequency analysis<br />

(1/1, 1/3 octave), “Flashcard”<br />

Enhanced sound level meter firmware<br />

Data logging, Frequency analysis<br />

NATA certificate<br />

Yes<br />

OH&S<br />

General<br />

OH&S<br />

General<br />

Analysis<br />

BK,7815 Software n/a Compatible with bK4443, 2239A, 2238E-NATA n/a Advanced applications<br />

ARL,EL-215<br />

ARL,EL-315<br />

ARL,EL-316<br />

bK,2238NMT-KIT<br />

IVI,IE35-2p<br />

Environmental noise<br />

logger<br />

Audio Analysis<br />

System<br />

2<br />

1<br />

1<br />

2,048 data sets, Weatherproof<br />

7,500 data sets, Display<br />

Weatherproof<br />

7,500 data sets, Display<br />

Weatherproof<br />

25MB memory, Weatherproof<br />

With sound level meter<br />

Includes pDA, real time analysis, FFT, signal<br />

generation, reverb, “seat-to-seat”, pC download<br />

Yes Long term outdoor logging<br />

General Analysis<br />

Engineering, Audiovisual


B&K Noise Monitoring Terminal with model 2238F SLM<br />

bK,2238NMT-KIT AU<br />

Noise logging system with B&K model 2238F Class 1 Sound Level Meter<br />

equipped with internal software for Basic SLM and Logging. Portable,<br />

wheeled weatherproof case. Standard SLM operation for fast, slow and<br />

impulse time weighings and A, C or linear frequency weightings RMS. Linear<br />

or C frequency weightings for peak detection. Internal memory 2Mb total<br />

for logging up to 12 parameters including auxiliary signals. Fitted with serial<br />

RS232 interface, and provided with bKlink software for download of logged<br />

data to pC. Supplied with field calibrator, charger and 12V, 18Ah battery, for<br />

operation for up to 14d logging at 15min intervals.<br />

B&K 4443 Noise Dose Meter with Logging<br />

bK,4443 AU/NZ<br />

Fitted with remote microphone, for OH&S surveys. Logging of 1 or 2<br />

parameters from a range of 6, with variable interval. 4 built-in and 3 userdefined<br />

setup routines, 5 selectable statistical levels Lx. Storage of up to<br />

53,000 values over 16 measurement periods, and download [or setup] via<br />

PC using software provided. Supplied complete with field calibrator. Battery<br />

powered.<br />

B&K 2237A Type 2 Integrating Sound Level Meter<br />

bK,2237A AU<br />

Measures RMS and peak simultaneously. Linearly weighted analogue output<br />

for sound recording, 0~0.5V ac (rms). Measurement range 30~140db.<br />

Time weightings fast, slow & impulse. Independent frequency weightings<br />

A [for RMS readings SpL, MaxL, MinL, Leq, Inst] and C [for peak readings<br />

peak and Maxp]. Real time clock for time and date stamp. Records 40<br />

measurements for download to PC. Calibrator included. Battery operated.<br />

Quest 2400 Type 2 Sound Sound Level Meter<br />

QUE,2400 NZ<br />

Type 2 sound level meter with LCD display for sound pressure level (SPL) or<br />

maximum level (MAx). Frequency weightings A & C, time weightings Fast<br />

and Slow. Ranges 30~140dbA and 40~140dbC with overload indication. AC<br />

& dc outputs. Battery powered.<br />

Rion NL-04 Sound Level Meter<br />

RIO,NL-04 MY<br />

Meets IEC type 2. Five measurement functions: Lp(SpL), Leq, LAE, Lmax &<br />

Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. built-in<br />

RS232C interface for computer communication. 70dB dynamic range (digital<br />

display), 27~130db (A) measuring range. Wide range of time settings for<br />

Leq, LAE, Lmax & Lx;10s,1,5,10, 15, 30min,1, 8, 24h & manual time setting<br />

(up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display, 0.1db<br />

resolution, updated every second, plus 60dB analog display display 1dB<br />

resolution showing the instantaneous value. Memory battery back-up. AC &<br />

DC signal o/p for level expanding system by optional filters, memory card &<br />

others.<br />

Rion NL-05 Type 2 Sound Level Meter<br />

RIO,NL-05 AU<br />

Sound level meter to IEC 651/1979 & IEC 804/1985 type 2 requirements.<br />

Measures Lp, Lmax, Leq, Lae. Response types A, C, and flat. Fast and<br />

slow time weightings. Complete with calibrator. Internal memory and printout<br />

for Leq data (printer Cp-10 optional, also prints other parameters),<br />

RS232C interface. Recorder outputs 1V ac rms & 3.5V dc. Operates from<br />

batteries or ac adaptor.<br />

Rion NL-11FP Sound Level Meter System<br />

RIO,NL-11Fp MY<br />

Sound level meter complete with type Nx-01A octave filter, Cp-01 printer, &<br />

calibrator. Measures Leq, Le (Lax), Spl and time. Weighting filters A, C, and<br />

flat. Detector reads fast, slow, impulse, and peak (IEC 651). Measurement<br />

range 29 ~140 db rms.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

nOiSe & SOund analySerS<br />

B&K 2239A Type 1 Sound Level Meter NATA Certification<br />

bK,2239A-NATA AU<br />

Type 1 (class 1) integrating sound level meter with backlit LCD display, NATA<br />

certification. Simultaneous rms (A,C) & peak (C) detection with independent<br />

frequency weightings. Measuring range 30~140db. Time weightings fast,<br />

slow and impulse. parameters Leq, Maxp, MaxL, MinL, peak, SpL and<br />

Inst. Memory for 40 data records with realtime clock. Serial port for data<br />

download. Calibrator included. Operates with 4 x AA alkaline batteries.<br />

Rion NL14 Type 1 Sound Level Meter/Analyser<br />

RIO,NL14 AU/MY<br />

Precision integrating sound level meter meeting IEC type 1 standard. Fitted<br />

with Nx-04 single octave filter module range 31.5~16kHz in 10 bands.<br />

Supplied with NC73 calibrator. Weightings A, C, & flat. Measurement range<br />

with A weighting 25~130dbA. Measurement functions Lp (SpL), Lmax, Leq,<br />

Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold. Leq time<br />

from 10s~100h. In-built memory for up to 9,000 readings (Lp). Outputs 1V<br />

ac rms, 3.5V dc, RS232C interface. Continuous operation on batteries for<br />

12h. AC adaptor included.<br />

Rion NL14 SLM with 1/3 & 1/1 Octave Filter NATA Certification<br />

RIO,NL14-NATA AU<br />

Precision integrating sound level meter to IEC type 1 (class 1) specification,<br />

with NATA certification. Supplied with 1/1 & 1/3 octave filter module Nx-05,<br />

and calibrator NC73. Frequency range 20~12,500Hz with weightings A, C, &<br />

flat. Measurement range (A) 25~130db. Measurement functions Lp (SpL),<br />

Lmax, Leq, Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold.<br />

Leq time from 10s~100h. In-built memory for up to 9,000 readings (Lp).<br />

Outputs 1V ac rms, 3.5V dc fs, RS232C interface. Alkaline batteries 12h<br />

operation or ac adaptor.<br />

Rion NL-31 Type 1 SLM with 1/1 & 1/3 Octave Filter<br />

RIO,NL31 NZ<br />

Complies with standards, IEC60651: 1979 Type 1, IEC60804: 1985 Type 1,<br />

IEC/CDV: 61672-1 Class 1. Simultaneous measurement of: sound level (Lp),<br />

equivalent continuous sound presure level (Leq), sound exposure level (LE),<br />

Maximum (Lmax) & Minimum (Lmin), percentile sound pressure level (LN),<br />

5 selectable settings. Measurement ranges are: A weighting: 28~138db,<br />

C weighting: 33~138db, flat: 38~138db, peak sound level: 141db. Time<br />

weightings are: fast, slow, impulse (impulse is selectable only for auxiliary<br />

processing functions). Ranges 100db dynamic, frequency 20~12,500Hz<br />

(including microphone). Timer function for automatic measurement over<br />

extended periods. Supplied with Nx-21SA 1/1 and 1/3 octave filter card.<br />

Rion NL-32 SLM with RTA & NATA Certification<br />

RIO,NL-32RTA-NATA AU<br />

RIO,NL-32 NZ<br />

Precision integrating sound level meter to IEC type 1 (class 1) specification,<br />

with NATA calibration. Fitted with internal Compact Flash Card reader<br />

and supplied with NC-74 field calibrator. Frequency range 20~20,000Hz<br />

with weightings A, C, and flat. Time weightings fast, slow and impulse.<br />

Measurement range (A) 28~138 db. broadband measurement functions<br />

Lp (SpL), Leq, Lmax/min, Lae, Lx, and selectable auxiliary functions with<br />

manual or auto storage [logging]. Measurement time (Leq) from 10 seconds<br />

to 200 hours. Inbuilt memory for up to 100 data sets, or to limit of fitted CF<br />

card using manual or auto storage. AC or dc outputs, RS232C interface and<br />

cable CC-93 for serial printer. Supplied with Nx-22RT card for real time 1/1<br />

and 1/3 octave analysis and display, for measurement functions Lp, Leq,<br />

LE, Lmax and display of Ap (all-pass) Ap(A) and 1/1 or 1/3 octave values<br />

as selected, with manual data storage only to Nx-22RT card. Download of<br />

card-data to pC requires flashcard reader. Alkaline batteries (24h operation)<br />

or AC adaptor.<br />

OCCUPATIONAL HEALTH & SAFETY<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 121


OCCUPATIONAL HEALTH & SAFETY<br />

122<br />

nOiSe & SOund analySerS<br />

B&K 2238E Type 1 Integrating SLM Enhanced Software &<br />

Logging<br />

bK,2238E-NATA AU<br />

Type 1 (class 1) Integrating sound level meter with additional functions<br />

including enhanced software, frequency analysis and data logging. Standard<br />

routines include functions for workplace measurements and general soundlevel<br />

checks; enhanced software (firmware) offers additional measurements<br />

and statistics for assessment of environmental noise problems; frequency<br />

analysis automates measurements in the 9 single octave bands and 29 1/3<br />

octave bands. Supplied with field calibrator. Compatible with BK,7815 Noise<br />

Explorer Environmental software for download, data analysis and display.<br />

B&K 7815 Environmental Software - Noise Explorer<br />

bK,7815 AU<br />

Software package for downloading and reporting of noise data measured<br />

with B&K meters. Compatible with sound level meters (2239, 2238) and<br />

noise dosemeters (4443). Offers data transfer, formatting of data for export,<br />

display and print in tabular or graphical form, file management and calculation<br />

of sound power or sound reduction index from intensity measurements.<br />

ARL EL-215 Environmental Noise Logger<br />

ARL,EL-215 AU<br />

Environmental noise logger. portable, self-contained and weatherproof.<br />

Monitors environmental noise continuously for up to 3 weeks. Calculates<br />

and stores 2048 sets of measured data. Continuous 90db dynamic range. A<br />

and C frequency weightings. Logs date, time, Leq, Lmax, L1, L5, L10, L50,<br />

L90, L95, L99, Lmin, temperature and battery (plus additional sensor). Scan<br />

interval 1 min~1 hour. RS232C interface. pC required for initial setup and<br />

results download.<br />

Oh&S & envirOnmental - general<br />

TSI SidePak SP730 Personal Sampling Pump<br />

TSI,Sp730 AU<br />

Personal sampling pump with internal digital flowmeter. Flow range<br />

to 3,000ml/min with internal low-flow bypass for precise control and<br />

measurement at low and high rates. Keypad programming with lockout<br />

option. Multimode operation for manual control and preset programs with<br />

intermittent sampling. Supplied with “Trakpro” data analysis software and<br />

USb interface. battery powered, 2,700mAH rechargable NiMH gives up to<br />

18.5h at 1L/min. Intrinsically safe.<br />

ARL EL-315 Environmental Noise Logger<br />

ARL,EL-315 AU/NZ/MY<br />

Environmental noise logger with display for field-reading of summary results.<br />

portable, self-contained and weatherproof. Continuous 90db dynamic range,<br />

frequency weightings A and C. Monitors environmental noise continuously<br />

for up to 3 weeks, calculates and stores over 7500 sets of Ln indices. pC<br />

required to set up system and download data using software supplied. Set<br />

up also possible from front-panel.<br />

Severn Model Tortus II Floor Slip Tester<br />

SEV,TORTUSII AU<br />

Floor friction tester. Measures and records the dynamic coefficient of<br />

friction. Applications in assessing floor safety, evaluating cleaning methods<br />

and maintenance procedures, accident investigation, etc. Meets the draft<br />

requirements of international, Australian and New Zealand standards.<br />

Lion Breath Alcohol Analyser<br />

LIO,SD-400p AU<br />

portable breath alcohol analyser with attached printer. Uses disposable<br />

mouthpieces. Approved by most law-enforcement agencies.


Model O 2 CO CO 2 NO NO 2 SO 2 H 2 S CH 4<br />

Efficiency<br />

Calculations<br />

TES,325-1 Y Y Y* Y<br />

gaS analySiS & mOnitOring<br />

Notes<br />

Industrial<br />

Domestic & light<br />

Oil & gas burners<br />

Temp °C<br />

Max<br />

Type<br />

600 Combustion efficiency<br />

TES,300M Y Y Y* Y Y<br />

Domestic<br />

1,200 Combustion efficiency<br />

TES,325M<br />

TES,335<br />

Y<br />

Y Y<br />

Y<br />

Y Y Y Y<br />

Industrial<br />

Industrial<br />

500<br />

1,000<br />

Flue Gas Analyser<br />

TES,350 Y Y Y* Y Y Y Y Domestic<br />

Industrial<br />

Power generation<br />

General<br />

1,200<br />

Combustion<br />

Flue Gas analysis<br />

TES,350xL Y Y Y Y Y Y Y 1,000 Combustion efficiency<br />

LAN,SERIES2-6 Y Y Y* Y Y Y Y Y<br />

NOV,1637-5CGA Y Y<br />

ISC,MDU420 Y<br />

*Calculated<br />

Model O 2<br />

ISC,ITx-STD<br />

ISC,TMx412<br />

ISC,MG140<br />

30%<br />

LEL<br />

(combustion)<br />

50 ppm (CH 4) to<br />

100% LEL<br />

100%<br />

C O<br />

ppm<br />

1,000 1,000<br />

Domestic, Industrial<br />

Power generation<br />

O 2 by Zirconia sensor<br />

CO 2 by NDIR<br />

Dual range<br />

NDIR methane analyser<br />

1,000<br />

Combustion<br />

Flue Gas analysis<br />

~600 Flue gas analysis<br />

~1,000<br />

Flue gas and general<br />

analysis<br />

Methane<br />

H 2 S Other Notes Applications<br />

Full confined space kit<br />

Logging & download<br />

Full confined space kit<br />

AIM,4650 25% 1,500 500 Logging<br />

NOV,1637-5<br />

from 1<br />

ppm<br />

CO 2 ~100 %<br />

ISC,MDU420 CH 4 ~100 %<br />

AER,500L portable Logging Ozone Monitor<br />

ppM,FORM400<br />

O 3<br />

0~0.500ppm<br />

Formaldehyde<br />

0.05~10.00 ppm<br />

Zirconia & NDIR sensors<br />

Wide range<br />

NDIR sensor<br />

Logging & download<br />

Mains or battery<br />

Logging & download<br />

Formaldehyde emissions<br />

from resins, furniture, textiles,<br />

etc<br />

Personal monitoring<br />

Confined space entry<br />

Personal monitoring<br />

General purpose<br />

Scientific<br />

Food packaging<br />

General purpose<br />

Landfill methane<br />

Indoor air quality<br />

“Sick building” syndrome<br />

LIO,SD-400p Alcohol Approved design Breath – alcohol<br />

RAE,MR200<br />

bAC,LEAK10<br />

ION,GASCHECK3000<br />

Detects, screens and measures VOC contaminants. Sensitive to<br />

benzene, Ammonia, Gasoline vapour and many more.<br />

portable leak detector for combustion gases. Detects methane<br />

to ~ 20 ppm<br />

portable leak detector using thermal conductivity.<br />

Wide range of gases including helium.<br />

ApT,ODA6000Cp Portable Gas Monitor<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Photoionisation detector<br />

Visual & audible leak<br />

indication<br />

Visual & audible signal<br />

Carbon Monoxide<br />

Nitrogen Dioxide<br />

Environmental & OH&S<br />

General<br />

Environmental & OH&S<br />

Heating, Ventilation & Aircon<br />

(“HVAC”)<br />

General purpose<br />

High sensitivity<br />

Car parks<br />

Loading Areas<br />

GAS ANALYSIS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 123


GAS ANALYSIS<br />

124<br />

gaS analySiS & mOnitOring<br />

> NEW<br />

Testo 335 Combustion Gas Analyser<br />

TES,335 AU<br />

portable industrial flue gas analyser. Determines temperature (to ~1000<br />

deg C), draught/pressure (±40hpa), oxygen (21%), carbon monoxide<br />

(10,000ppm) and nitric oxide NO (3000ppm) concentrations. Calculates<br />

carbon dioxide concentration, efficiency and flue gas loss. Thresholdprotection<br />

of sensors, with 5x autodilution of CO to 50,000ppm. Separate<br />

sensor-socket with mini-probe for ambient temperature, and connection<br />

points for compatible differential-pressure devices. built-in condensatetrap<br />

with warning and auto-switch-off. Internal memory [100 folders x 10<br />

locations x 200 datasets each] for storage of measurement-protocols and<br />

data for printout. Supplied as kit with 335mm probe, cone and shield-plate,<br />

cordless printer and power supply. Rechargeable or AC operation (alkaline<br />

batteries used by printer).<br />

> NEW<br />

Testo 325M Combustion Gas Analyser<br />

TES,325M AU<br />

Portable flue gas analyser for tuning, maintenance and service adjustments<br />

of oil and gas burners. Determines temperature (to ~500ºC), draught/<br />

pressure, oxygen (21%) and carbon monoxide (4000ppm) concentrations.<br />

Calculates carbon dioxide concentration and gross/net efficiency. Supplied<br />

as kit with probe, cordless printer and power supply for mains operation.<br />

Operation 230Vac (with power supply) or alkaline batteries (AA also required<br />

by printer).


Testo 325-1 Combustion Gas Analyser<br />

TES,325-1 AU<br />

Portable flue gas analyser for measurements and adjustments of oil and<br />

gas burners. Determines temperature (to 600 O C), draught/pressure, oxygen<br />

(21%) and carbon monoxide (2,000ppm) concentrations. Calculates CO 2<br />

concentration and gross/net efficiency. Supplied as kit with probe, cordless<br />

printer and power supply for mains operation. Operation 230V ac (with<br />

power supply) or alkaline batteries (AA, also required by printer).<br />

Testo 300M Combustion Gas Analyser<br />

TES,300M AU/NZ/MY<br />

Flue gas analyser for combustion efficiency measurement. Temperature<br />

range -40~1200 O C ±0.5 (100) with gas probe operation to<br />

1,000 O C max. Draught/pressure range 80mbar, ±0.03 . Gases measured: O 2<br />

0~21%, ±0.2%; CO 2 [calculated] 0~CO 2 max %vol ±0.2%; CO 0~8,000ppm,<br />

±20 (


GAS ANALYSIS<br />

126<br />

gaS analySiS & mOnitOring<br />

ISC MG140 4-gas Personal Monitor for CH4 4 , O 2 , CO & H 2 S<br />

ISC,MG140 AU<br />

Four gas personal monitor for combustible gases (% LEL), oxygen (% O2),<br />

carbon monoxide (ppm CO) and hydrogen sulphide (ppm H2S). International<br />

approvals UL & CSA - class 1, groups A, b, C & D. Audible [90db] and visual<br />

alarms. Supplied with case and belt-loop, calibration cup and battery charger.<br />

Run time 8-10h on full charge.<br />

ISC Gas Monitor for CH 4 , O 2 , CO & H 2 S<br />

ISC,TMx412 AU/NZ<br />

Four gas monitor complete with confined space entry kit. Detects 4 gases<br />

flammable (CH 4 ), oxygen (O 2 ), carbon monoxide (CO) and hydrogen sulphide<br />

(H 2 S). Measures % LEL flammable, % O 2, ppm CO & H 2 S. Intrinsically safe<br />

EEx ia T4 rated (Australian Approved). Confined space entry kit includes<br />

sampling pump, tubing, filters and carry case. Designed to test confined<br />

spaces from a safe area prior to entry. Supplied in carry case complete with<br />

training video and battery charger. Other sensor options available at extra<br />

cost. battery pack run time 8h (18h with lithium batteries).<br />

ISC ITX 4-Gas Monitor Confined Space & Logging<br />

ISC,ITx-STD AU<br />

Multi-gas monitor with confined-space kit and logging option. Configured<br />

for 4 gases: combustible 50ppm~100%LEL, oxygen 0~30%, CO 0~999ppm<br />

& H 2 S 0~999ppm. Intrinsically safe: Ex ia d I/IIC T4[Australia]. Confined<br />

space kit includes motorised pump, tubing, calibration cup and regulator.<br />

Logging option by time or event, up to 300h survey data at 1min intervals,<br />

with datalink/software for download. Includes training video, Li-ion battery<br />

pack with charger, and backup alkaline-battery pack.


did yOu knOW….<br />

yOu can Obtain<br />

quOteS Online,<br />

quickly and<br />

eaSily, With Our<br />

perSOnaliSed<br />

quOting SyStem?<br />

viSit Our WebSiteS,<br />

brOWSe the<br />

catalOgue and<br />

Select the<br />

prOductS yOu are<br />

intereSted in – it<br />

cOuldn’t be eaSier.<br />

www.techrentals.com.au<br />

www.techrentals.co.nz<br />

www.techrentals.com.my<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

gaS analySiS & mOnitOring<br />

GasCheck 3000 Portable General-purpose Leak Detector<br />

ION,GASCHECK3000 AU<br />

portable leak detector. Micro thermal-conductivity sensor for high-sensitivity<br />

detection of gases with a thermal conductivity different to that of air, including<br />

helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in<br />

five groups. Direct reading of leak rate in ml/s with audio and visible signals.<br />

Detection limit for helium 2E-5ml/s. battery powered.<br />

RAE Systems Minirae 2000 Portable PID<br />

RAE,MR2000 AU<br />

Portable handheld VOC (Volatile Organic Compound) monitor with data<br />

logging. 3-D pID sensor (photo-Ionisation Detector) fitted with 10.6eV lamp.<br />

Ranges 0~999ppm (resolution 0.1) or 100~10,000ppm (resolution 1) VOC<br />

expressed as isobutylene. built-in correction factors for 102 compounds<br />

from a total standard library of 250. Integrated pump for local or remote<br />

(30m) sampling, with stall protection against liquid ingress. Downloadable<br />

data logging for 1,500 points with time, data and header. Intrinsically safe.<br />

Up to 10h operation with rechargeable (NiMH) or alkaline batteries.<br />

Novatech O and CO Analyser/Transmitter<br />

2 2<br />

NOV,1637-5 AU<br />

Oxygen and carbon dioxide analyser for packaging atmosphere, general<br />

industrial and research use. Oxygen sensor reading 1ppm to 100% with<br />

1% accuracy. NDIR carbon dioxide analysis 0~100% ±3% of full scale. 2<br />

x 4~20mA outputs, 1 common & 3 selectable alarm relays. Gas connection<br />

1/8 Swagelok. Flow rate with internal pump 100~500cc/min. AC operation.<br />

ISC MDU420 Logging Methane Monitor<br />

ISC,MDU420 AU<br />

Dual-range methane monitor with non-dispersive infrared sensor. Low range<br />

0~100% LEL, and auto-range 0~100% methane by volume. Internal pump<br />

for ambient air or stream sampling. Datalogging included, with software and<br />

cable for download. Supplied with 450mm stainless steel probe for flue gas<br />

analysis. Rechargeable, with alkaline-battery pack as backup.<br />

> NEW<br />

Odalog NO2 & CO Area Monitor for vehicle-parks & IAQ<br />

ApT,ODA6000Cp AU<br />

portable multi-gas monitor for area air-quality measurement, logging<br />

or personal monitoring in car-parks, loading areas and related zones.<br />

Configured for carbon monoxide (from petrol vehicles) and nitrogen<br />

dioxide (from diesel vehicles). Ranges CO 0~500ppm (to 1ppm) and NO2 0~50ppm (to 0.1ppm). Dust and water sealed to Ip66, and rated intrinsically<br />

safe for general or mines use. Logging memory 500K readings. Integral<br />

infrared communications interface, with software and IrDA USb adaptor for<br />

configuration and download. Rechargeable, approximately 7 days operation<br />

on full charge.<br />

GAS ANALYSIS<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 127


GENERAL ENVIRONMENTAL<br />

128<br />

electrOchemiStry, Water quality<br />

> NEW<br />

Anton Paar DMA 35N Portable Density Meter<br />

pAA,DMA35N AU<br />

Portable density, specific gravity & concentration meter. Measuring range<br />

0.000~1.999 g/cc and 0.0~40.0ºC. built-in pipette style pump for sample<br />

aspiration, with port for optional syringe-filling. Display of specific gravity,<br />

ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically<br />

safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage<br />

of up to 1024 results, with recall, and infrared port for RS232 download to<br />

serial printer or PC. Wetted parts glass and PTFE. Battery powered.<br />

> NEW<br />

TPS WP-80 pH and Temperature Meter<br />

TpS,Wp-80 AU<br />

portable hand-held meter for pH, mV and temperature. Supplied with<br />

combination pH electrode and separate temperature sensor on 1m cables.<br />

Operating ranges 0.00~14.00pH and -10.0~120.0ºC [automatic sensor<br />

recognition with auto pH correction 0~100ºC]. Case water resistant to Ip67,<br />

connectors to Ip65. Menu driven, with alphanumeric display. Auto storage<br />

of time and date of last calibration for GLp. Memory for 2400 readings of<br />

data, time and date, for Notepad results collection, or for AutoLog with<br />

logging intervals between 1 sec and 90 hr. Fitted with RS232C interface<br />

and supplied with download-software, charger and solutions. Rechargeable<br />

NiMH battery gives up to 50 hr operation.<br />

TPS LC80A Portable pH Meter<br />

TpS,LC80A AU<br />

battery operated with LCD display. Automatic temperature compensation,<br />

and analogue recorder output. Complete with combination electrode/<br />

temperature probe with a max temperature of 60OC. Display has ranges:<br />

0~14ph, 0~199mV, & -10~199OC. TPS Redox Electrode<br />

TpS,REDOx AU<br />

Silver/chloride Redox electrode for use with TpS LC80A ph meter. Supplied<br />

with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx.<br />

231mV.<br />

TPS WP-88 Turbidity & Temperature Meter with 8m Cable<br />

TpS,Wp88 AU<br />

portable hand-held turbidity and temperature meter for field or laboratory<br />

use. Sensor probe diameter 45mm, with 8m cable. Turbidity ranging 0.1~<br />

200/2000NTU ±1NTU with autoselection. Temperature compensation and<br />

sensor range 0~ 60ºC ±0.1ºC. Case water resistant to Ip67, connectors to<br />

IP65, with detachable cable and sensor. Menu driven, with alphanumeric<br />

display. Auto storage of time, date and results of last calibration for GLp.<br />

RS232C interface, and memory for 150 readings of data, time and date,<br />

for Notepad results collection, or for AutoLog results collection with logging<br />

intervals between 1min and 24h. Rechargeable NiMH battery gives up to<br />

50h operation. Supplied with download-software, charger and calibration<br />

solutions.<br />

TPS WP-82 Dissolved Oxygen Meter<br />

TpS,Wp82 AU<br />

portable hand-held dissolved oxygen and temperature meter. Operating<br />

ranges 0~20ppm, 0~240% saturation, 0~45% gaseous and ppm with salinity<br />

correction. temperature range -10~120 O C. Case water resistant to IP67,<br />

connectors to IP65, with 3m detachable cable and ED1 electrode. Menu<br />

driven, with alphanumeric display. Auto storage of time and date of last<br />

calibration for GLP. RS232C interface, and memory for 150 readings of<br />

data, time and date, for Notepad results collection, or for AutoLog results<br />

collection with logging intervals between 1min & 24h. Rechargeable NiMH<br />

battery gives up to 75h operation. Supplied with download-software, charger<br />

and solutions.


TPS WP-84 Conductivity Salinity Temperature Meter<br />

TpS,Wp-84 AU<br />

portable hand-held meter for conductivity, TDS (Total Dissolved Solids) and<br />

temperature. Automatic range selection with 5 ranges. Case water resistant<br />

to Ip67, connectors to Ip65. Menu driven, with alphanumeric display for fulltext<br />

prompting. Storage of time and date of last calibration for GLP. Memory<br />

for 150 readings of data, time and date, for Notepad results collection, or<br />

for AutoLog results collection with logging intervals between 1min & 24h.<br />

Rechargeable NiMH battery gives up to 75h operation. Supplied with sensor<br />

(k=1), charger and solutions.<br />

YSI 55D Dissolved Oxygen Meter<br />

YSI,55D NZ<br />

Measures dissolved oxygen in mg/L or percent saturation. Range is 0~20mg/<br />

L, resolution is 0.01mg/L, accuracy is 0.3mg/L. provides simultaneous<br />

readings of O2 & OC. Dissolved O2 readings are automatically compensated<br />

for temperature. Offering push-button calibration with a built-in calibration<br />

chamber, direct salinity, and altitude compensation. Supplied with 3m cable<br />

to probe.<br />

YSI 550A Dissolved Oxygen Meter with 12ft Cable<br />

YSI,550A NZ<br />

Handheld microprocessor based dissolved oxygen meter for use in fresh<br />

water, sea water or polluted water. Range 0~50mg/l resolution is 0.01 or<br />

0.1. Air saturation range is 0~500% resolution is 0.1 or 1 air saturation.<br />

Temperature range is -5°C~45°C resolution is 0.1. Features: Self-diagnostics<br />

on power up. Compensation for altitude, salinity & temperature, waterproof<br />

to Ip-67, push-button calibration, built-in calibration cha mber. Over 2,000h<br />

(alkaline) battery life at 25°C. Supplied with 4m probe lead.<br />

YSI 63 pH Salinity and Conductivity Meter<br />

YSI,63-10 NZ<br />

Measures temperature, pH, conductivity, and salinity. Ranges are: 0~14pH,<br />

resolution 0.01, conductivity is 0~200mS/cm over 4 ranges, salinity is<br />

0~80 ppt, resolution 0.1, temperature is -5~75OC, resolution 0.1. Stores<br />

50 readings with ID, user-selected scale or autoranging for conductivity.<br />

Supplied with a 15m cable to probe.<br />

Horiba U-20 Multi-function Water Quality Meter<br />

HOR,U-20xD1 AU<br />

Multi-parameter water quality monitor with 30m cable. Waterproof Meter<br />

unit rated to IP67 with LCD display, analog output and RS232C interface for<br />

data download using software supplied. Detachable probe, 47mmØ with<br />

stainless steel cover suitable for use in 50mm wells, with sensors for pH/<br />

ORp, dissolved oxygen, conductivity/salinity/TDS/seawater specific gravity,<br />

temperature, turbidity and depth. Data logging up to 1m @ 15min intervals.<br />

Alkaline battery operation.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

electrOchemiStry, Water quality<br />

Hydrolab Quanta Multiprobe Water Quality Meter<br />

HYD,QT-Mp-A AU<br />

Multi-parameter water quality analyser with 15m cable. Meter unit rated to<br />

NEMA6 (waterproof), with simultaneous parameter display, realtime manual<br />

storage of 100 frames of data and SDI interface. Transmitter probe with<br />

sample circulator, fitted with sensors for temperature, specific conductance/<br />

salinity, dissolved oxygen, pH, ORp and turbidity. Operates on 3 x C size<br />

batteries.<br />

TPS Water Quality Meter<br />

TpS,90FL-T AU<br />

Field meter and logger for water quality measurements. Configured with<br />

independent probes for pH, conductivity/salinity[TDS]/temperature, dissolved<br />

oxygen[DO] and turbidity. Cables 5m with probe holder and safety harness.<br />

LCD display readout with simultaneous display of all measurements.<br />

Manual, “notepad” storage or automated data logging for up to 1,808 sets<br />

of readings by time and date. RS232C interface, with WinTPS software<br />

included. Supplied with rechargeable battery, and clip-lead for operation<br />

from a 12V source such as a car-battery.<br />

Hanna Portable Turbidity Meter with Case & Kit<br />

HAN,HI93703C AU<br />

Microprocessor-based, portable turbidity meter operating in the range 0~<br />

50FTU x 0.01FTU or 50~1,000FTU x 1FTU(NTU). Long-life IR LED source<br />

peaking at 890 nm for reduced colour-interference. Compliant with ISO7027<br />

requirements. Unique GLp feature allows automatic storage and recall<br />

of last calibration value with time and date. Supplied in carry-case with<br />

measuring cuvettes, and maintenance kit. battery operation.<br />

GENERAL ENVIRONMENTAL<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 129


GENERAL ENVIRONMENTAL<br />

130<br />

electrOchemiStry, Water quality<br />

Analite NEP160-1 Turbidity Meter<br />

ANA,NEp160 NZ<br />

Portable turbidity meter suitable for potable or waste water measurements<br />

depending on the probe type. Supplied with either NEp280 100~20,000NTU<br />

waste water retro-scatter probe on a 5m cable or NEp260 0~3,000NTU<br />

potable water probe with 25m cable. Display resolution for the NEP280<br />

probe is 10NTU, NEp260 probe is 1NTU. Repeatability is ±2% +1 digit on<br />

all ranges. Data logging up to 100 time & date stamped readings with sample<br />

intervals from 1s~90min. Analogue output with a range of 0~2V fs on any<br />

range. RS232C interface which can output readings on request or at preset<br />

intervals from 1~99s or min.<br />

DKK TOA Model RC-24P Portable Residual Chlorine Meter<br />

DKK,RC-24p-Dp AU<br />

portable, direct-reading residual chlorine meter for water analysis. Range<br />

0~2mg/L [ppm]. Reagent-free measurement with electrode, 3m cable, float<br />

and sample container for in-situ or grab-sampling. Compatible with direct<br />

chlorination, hypochlorite or dichloroisocyanurate dosing. Calibration data<br />

stored in electrode with correlation with DPD methods. Waterproof to IP67.<br />

ISO validation functions, storage of 300 measurements and RS232 printer<br />

output. Battery operated.<br />

Aquafluor Handheld Fluorimeter for Rhodamine WT &<br />

Fluorescein<br />

TUR,AQF-RF AU<br />

Dual-channel handheld field fluorimeter. Configured for water-tracing by detection<br />

of rhodamine WT and fluorescein dyes, detection limit ~0.4ppb. RWT channel<br />

excitation 540nm, emission >570nm; Fluorescein channel excitation 475nm,<br />

emission 515nm. Internal data logging for 1000 data points, with download.<br />

Battery operated.<br />

Spectronic Helios Epsilon Spectrophotometer Visible<br />

SUV,EpSILON1 AU<br />

Single beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth,<br />

operating in the range -0.1~2.5A. Wide view-angle LCD display and<br />

sealed membrane keypad with push button auto-zero. Sealed optics,<br />

with wavelength slew >4500nm/min. Operational modes absorbance,<br />

transmission, concentration and factor. Supplied with standard cellholder<br />

for 10mm square cells. RS232C port for computer and parallel interface<br />

for printer.<br />

Van Essen Depth/Temperature Groundwater Logger 30M<br />

VAN,TD30 AU<br />

Groundwater depth and temperature logger for operation to 30m. Independent<br />

probe 22mmØ x 125mm long with internal memory for 2 x 24,000 measurements,<br />

battery-life 8~10y. Reader for set-up and download of data using standard<br />

computer. Supplied with “baro Diver” - ambient/surface logger for atmospheric<br />

pressure correction.<br />

Isco 6700 Series Water Sampler with Bubbler Flow Module<br />

ISK,6700-730 AU<br />

Advanced water sampler for fully programmed collection. Samples can<br />

be collected in 1, 2, 8, or 24 glass or plastic sample containers based on<br />

time, flow, and/or parameter set points. Fitted with NEMA 4x,6 (Ip67) sealed<br />

controller featuring an exclusive, built-in pump, flash memory for easy<br />

programming changes, and a plug-in module port for connection of a flow<br />

meter module or parameter measurement module to enhance monitoring<br />

capabilities. Provided with bubbler flow module. Sample bottles available.<br />

Run from rechargeable 12V sealed batteries.


Shimadzu UV-Mini 1240 Spectrophotometer UV-Visible<br />

SHI,UV-1240 AU<br />

Single beam scanning UV-visible spectrophotometer, 190~1,100nm with<br />

5nm bandwidth. Large LCD display for on-screen viewing of results,<br />

calibration curves and spectra. Standard applications include photometric<br />

measurement, spectrum scanning and quantitation. IC data card system for<br />

storage of raw data, methods and results, with optional program packs for<br />

additional applications. Interface ports for printer or computer. 220~240V,<br />

50/60Hz.<br />

Spectronic Helios Epsilon Spectrophotometer Visible<br />

SUV,EpSILON1 AU<br />

Single beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth,<br />

operating in the range -0.1~2.5A. Wide view-angle LCD display and<br />

sealed membrane keypad with push button auto-zero. Sealed optics,<br />

with wavelength slew >4500nm/min. Operational modes absorbance,<br />

transmission, concentration and factor. Supplied with standard cellholder<br />

for 10mm square cells. RS232C port for computer and parallel interface<br />

for printer.<br />

> NEW<br />

Anton Paar DMA 35N Portable Density Meter<br />

pAA,DMA35N AU<br />

Portable density, specific gravity & concentration meter. Measuring range<br />

0.000~1.999g/cc and 0.0~40.0ºC. built-in pipette style pump for sample<br />

aspiration, with port for optional syringe-filling. Display of specific gravity,<br />

ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically<br />

safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage<br />

of up to 1024 results, with recall, and infrared port for RS232 download to<br />

serial printer or PC. Wetted parts glass and PTFE. Battery powered.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

SpectrOScOpy<br />

X-Rite SP60 Portable Sphere Colour Spectrophotometer<br />

xRI,Sp60 AU<br />

Portable spectrophotometer for surface colour measurements. Diffuse<br />

8 O [d/8] optical geometry with fixed 8mm aperture. Tungsten source<br />

for illuminant types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard<br />

observers 2 & 10 O . blue-enhanced photodiode detectors with spectral<br />

range 400~700nm. Measures opacity and colour by chromatic, apparent<br />

or tristimulus calculation, with simultaneous included and excluded specular<br />

component, and spectrum at 10nm intervals. Storage of up to 2,000 samples<br />

with results download to serial printer or computer. Operation from internal<br />

rechargeable battery or ac adaptor.<br />

materialS teSting<br />

Hydramotion Viscolite 700 Portable Viscometer<br />

HYL,V700S-21 AU<br />

Advanced portable viscometer with stainless-steel probe. Operating range<br />

0.1~10,000mpaps (cps) with integral temperature correction -40~150ºC.<br />

probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm<br />

(viscosity/temperature). Acetal polymer probe base for handheld or clamped<br />

operation, with coiled-cable connection to meter unit with 5 digit display.<br />

Battery powered.<br />

GENERAL ENVIRONMENTAL<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 131


did yOu knOW….<br />

yOu can regiSter<br />

Online tO receive<br />

advance nOtice<br />

Of neW prOductS,<br />

prOmOtiOnS and<br />

technical neWS?<br />

viSit Our WebSite<br />

and regiSter<br />

tOday.<br />

www.techrentals.com.au<br />

www.techrentals.co.nz<br />

www.techrentals.com.my


CALIBRATION


CALIBRATION<br />

134<br />

calibratiOn ServiceS. Online. Ontime. everytime.<br />

<strong>TR</strong> <strong>Corporation</strong> services also include calibration. These services<br />

are delivered through TECH<strong>RENTAL</strong>S and VMS.<br />

Our laboratories are staffed by experienced technical engineers<br />

and technical officers to provide internationally recognised calibration<br />

services. Utilising state-of-the-art specialised instrumentation, each<br />

is NATA accredited, with ISO quality systems in place for traceability<br />

and control.<br />

Our ServiceS:<br />

• calibration<br />

• rEpairs<br />

• salEs<br />

• total assEt<br />

managEmEnt<br />

• mobilE calibration<br />

facilitiEs<br />

induStrieS SuppOrted:<br />

• aviation<br />

• dEfEncE<br />

• ElEctrical<br />

• ElEctronic<br />

• biomEdical<br />

• mEchaical<br />

• tElEcommunications<br />

Why deal With uS:<br />

• ExpEriEncEd,<br />

qualifiEd staff<br />

• nata accrEditation<br />

• iso quality control<br />

• 22 convEniEnt<br />

locations<br />

• onlinE sErvicEs<br />

(australia only)<br />

• onE stop shop<br />

facility for all your<br />

calibration nEEds<br />

talk to your<br />

tEchrEntals<br />

consultant<br />

about how wE<br />

can hElp solvE<br />

your calibration<br />

problEms


a<br />

AC See Electrical<br />

Accelerometer 88-89<br />

Acoustic Spectrum Analysis 119<br />

Adhesion Tester 91<br />

Air<br />

Compressor Output 112<br />

Flow 112-117<br />

Quality 113-115, 117<br />

Air Conditioning<br />

Coolant Flow 110, 112<br />

Electronic Manifold 118<br />

Measurement 113-114<br />

Valve Balancing 118<br />

Air Quality<br />

Monitoring 113-115, 117, 126<br />

particles 113-114, 117<br />

Temperature & Humidity 113-114, 117<br />

Air Velocity Meter 112, 115<br />

Alcohol breath Analyser 122<br />

Alignment 88-89<br />

Ammeter 60, 62<br />

Amplifier Instrumentation 73<br />

Anemometer 113-115, 116<br />

Angle Measurement 63<br />

Antenna & Cable Test 18-19<br />

Antennas 19-20, 37<br />

Appliance Tester 46-47<br />

Area Heat Stress 113-114, 117<br />

Audio Analyser 26<br />

Autoclave Logger 70, 73<br />

Automotive Testing 90<br />

b<br />

Balances 85, 87<br />

Balancing Machinery 118<br />

balancing Machinery Analyser 88<br />

balometer 113-114, 115<br />

Barometric 102<br />

Barometric Recorder 102<br />

Bath<br />

Constant Temperature 94-95, 97<br />

Ultrasonic 100<br />

Bit Error Rate (BERT) 28<br />

Blast Logger 90<br />

body Vibration Measurement 88-89<br />

Bore Hole Depth 130<br />

Bore Hole Water Quality 129<br />

Borescope 79, 81<br />

brake Tester 90<br />

Bridge LCR 9<br />

c<br />

Cable<br />

Fault Locator 36-37<br />

LAN Test 32<br />

Locator 32, 36-37<br />

Tester 32, 36-37<br />

Tracer 36-37<br />

Cable Locator 36<br />

Cable Tester 36<br />

Cable TV 27<br />

Calibrator<br />

Current 94-97<br />

Current Loop 94-96, 98<br />

Dry block Temperature 94-95, 97-98<br />

Electrical 9<br />

Hydraulic 94-95, 99-100<br />

Industrial 94-95<br />

Loop 94-95<br />

pneumatic Instruments 94-95, 98<br />

pressure 94-95, 98-100<br />

process 94-96<br />

Resistance 94-96<br />

Temperature 94-95, 97-98<br />

Voltage 94-96, 98-99<br />

Caliper 78<br />

Camera<br />

Digital 106<br />

Endoscope 79, 81<br />

High Speed 82<br />

pipe Inspection 79-81<br />

Surveillance 106<br />

Thermal Imaging 104-105<br />

Video 82<br />

Carbon Dioxide (CO 2 )<br />

113-114, 117, 124-127<br />

Carbon Monoxide (CO)<br />

113-114, 117, 124-126<br />

Cat 5, 5E, 6 32<br />

CCTV Surveillance 106<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

Charge Amplifier 88-89<br />

Chart Recorder 76, 82-83<br />

Circuit breaker Analyser 58<br />

Circuit Tracer 36<br />

Clean Room Monitor 117<br />

Cleaver - Fibre Optic 35<br />

Coating Thickness 90-92<br />

Coil & Winding Test 41, 46<br />

Combustion Gas Analysis 123-126<br />

Communications Test Set 21<br />

Compressed Air Flow 112<br />

Compressor Output<br />

Flow 105<br />

Quality 105<br />

Concrete Testing<br />

Adhesion 91<br />

Cover Meter 92<br />

Moisture Meter 92-93<br />

Reo Depth 92-93<br />

Test Hammer 92-93<br />

Ultrasonic Tester 91-92<br />

Conductivity & Salinity 129<br />

Confined Space Entry 123, 126<br />

Counting Scales 87<br />

Crane Scales 86<br />

Current<br />

Clamp 46, 53-54, 57, 60-65, 75<br />

DC Source 7<br />

Injection 65<br />

Input Logger 70, 73<br />

Loop 94-95, 96-98<br />

Meter 48-49, 56, 60, 62-63, 110-111<br />

Primary Injection 65<br />

probe 4, 61-62<br />

Secondary Injection 65<br />

Sensor 75<br />

Shunt 60, 63<br />

Transducer 53, 60, 63, 75<br />

Transformer (CT) 48-49, 51, 56, 60<br />

d<br />

Data Communications<br />

Cable Test 32<br />

Etherscope 29<br />

Fibre Optics 33<br />

LAN Analyser 29<br />

Protocol analyser 31<br />

protocol Analyser 28, 30-31<br />

WAN analyser 31<br />

WAN Analyser 29, 31<br />

Data Logger 70-73, 83<br />

DC High Voltage 4, 59<br />

DC Power Supplies 7<br />

Decade Resistance Box 9<br />

Demand Analyser 48-49, 51, 56<br />

Density Meter 86, 128, 131<br />

Depth Logger 130<br />

Dewpoint 105, 113-114, 117<br />

Digital Camera 106<br />

Digital Storage Oscilloscope 2<br />

Dimension Measurement 78<br />

Dissolved Oxygen 128-129<br />

Distance Measurement 78<br />

Distortion Analyser/Generator 26<br />

Dose Meter (Noise) 120-121<br />

Dust Measurement 113-114, 117<br />

e<br />

E1/E3 Tester 28-31<br />

Earth Leakage 41- 45, 48-49, 59-60, 62, 65<br />

Earth Tester 46<br />

Electric Motor Test 46<br />

Electrical 40<br />

Electrical Cable Test 41-45, 59<br />

High Voltage 59, 65<br />

Surge Generator 36<br />

TDR 36<br />

VLF 59<br />

Electrical Installation & Test<br />

Appliance Tester 46-47<br />

Earth Leakage (RCD)<br />

41-46, 48-49, 60, 62, 65<br />

High Voltage Test (Hi-pot) 46, 59<br />

Insulation Test 40-45, 59<br />

Phase Rotation 63<br />

Resistance Test 41-45, 46<br />

Soil/Ground Resistance 41, 45-46<br />

Electrical Power Generation<br />

& Transmission<br />

Current Injection 65<br />

High Voltage Test (Hi-pot) 59<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

power Quality 48-54, 56<br />

Protection Relay Test 57<br />

VLF Test 59<br />

Electrical Power Quality<br />

Demand Analyser 51-54, 56<br />

Harmonics 48-49, 51, 56<br />

power Factor 48-49, 51, 53-54, 63<br />

power Quality Analyser 48-50, 53-56<br />

Voltage Current Recorder 76<br />

Electrical Power Sources<br />

Current Injectors 65<br />

Generator 68<br />

Line Conditioners 66<br />

UpS 66-67<br />

Electrical Testers 63<br />

Electrical Transducers 60, 62<br />

Electrochemistry 128<br />

Electrometer 5<br />

Electrostatic Charge Measurement 6<br />

EMC/EMI Test Equipment 21<br />

Endoscopes 79-81<br />

Environmental Chambers/Oven 100-101<br />

Environmental Noise 120, 122<br />

Ethernet Analyser 29-30<br />

f<br />

Fibre Optic Microscope 35<br />

Fibre Optics 33-34<br />

Fusion Splicer 35<br />

LAN Cable Test 32<br />

OTDR 34<br />

PMD 35<br />

power Meter/Light Source 33-35<br />

Field Strength Meter<br />

Gauss 40<br />

RF 19-20<br />

Field Strength Meters & Antennas 19-20<br />

Filters 26<br />

Flash Card 75<br />

Flaw Detector 90<br />

Floor Slip Tester 122<br />

Flow Meters 110-112<br />

Compressed Air 110, 112<br />

Doppler 110-112<br />

Gas 110, 112<br />

Liquid 110-112<br />

Non-Intrusive 110-112<br />

Open Channel 110-112<br />

Transit Time 110, 112<br />

Ultrasonic 110-112<br />

Flue Gas Analysis 123-125<br />

Flue Inspection 79-80<br />

Fluorimeter 130<br />

Force Gauge 84<br />

Formaldehyde Meter 123, 125<br />

Frequency Counter 12<br />

Frequency Response Analysers 10<br />

Frequency Transducer 60, 63<br />

Function Generator 8<br />

Fusion Splicer 35<br />

g<br />

Gamma Radiation 19-20<br />

Gas<br />

Alcohol 122<br />

Carbon Dioxide (CO 2 ) 117, 124-127<br />

Carbon Monoxide (CO) 117, 123-127<br />

Flammable (LEL) 125-126<br />

Formaldehyde 123, 125<br />

Hydrogen Sulphide (H 2 S) 125-126<br />

Methane (CH 4 ) 123, 125-127<br />

Nitric Oxide (NO) 117, 123-126<br />

Nitrogen Dioxide (NO 2 ) 123-127<br />

Oxygen (O 2 ) 123, 126-127<br />

Ozone (O 3 ) 125<br />

Refrigerant 118<br />

Sulphur Dioxide (SO 2 ) 123<br />

VOC 123, 127<br />

Gas Analysis &<br />

Monitoring 123, 125-127<br />

Gauss/Tesla Meter 40<br />

Generator (AC) 68<br />

Glossmeter 90<br />

GpIb Interface 4<br />

Ground Vibration 90<br />

Groundwater 130<br />

h<br />

Hardness Tester 93<br />

Harmonics (power) 48-50, 56<br />

Heat Stress 113-114, 117<br />

High Voltage Insulation Dielectrics<br />

Test Set 42<br />

Hi-pot Tester 46, 59<br />

Holiday Detector 91<br />

Hot Wire Anemometer 113-114, 116<br />

Humidity<br />

Chamber 101<br />

Concrete 92<br />

High Temp probe 77, 83-84<br />

Indoor Air 113-114, 117<br />

Logging 70, 72-73<br />

Natural Gas 105<br />

Recorders 102<br />

Thermohygrograph 102<br />

Transducer 77, 83-84<br />

Weather 118<br />

HVAC & IAQ 112-117<br />

Hybrid Recorders 76<br />

Hydraulic pressure 91, 94-95, 99-100<br />

i<br />

Illuminance Meter 119<br />

Inclinometer 84<br />

Indoor Air Quality 113-114, 117<br />

Infrared Camera 104-105<br />

Infrared Thermometer 102-103<br />

Injection Test Set 65<br />

Instrumentation Amplifier 73, 76<br />

Insulation Tester 41-45, 59, 65<br />

Intrinsically Safe<br />

Current Loop Calibrator 94-95, 98<br />

Digital Multimeter 6<br />

Gas Monitor 126<br />

Moisture Analyser 105<br />

Noise Dose Meter 120-121<br />

photo-Ionisation Detector (pID) 123, 127<br />

Inverter 68<br />

Ionisation Tester 59<br />

ISDN 28, 31<br />

l<br />

Laboratory Oven 101<br />

LAN<br />

Analyser 29-31<br />

Cable Certification 32<br />

Cable Tester 32<br />

Laser<br />

Distance & Speed 78<br />

Level 78<br />

LCR Meter 9<br />

Leak Detector<br />

Gas Pipe 37, 118, 125, 127<br />

Microwave Oven 19-20<br />

Refrigerant 118<br />

Water 37<br />

Light Measurement 119<br />

Light Meter 119<br />

Linear position Transducer 84<br />

Load Cell 85-86<br />

Logger 70<br />

Accessories 71<br />

Autoclave 70, 73<br />

Data 70-73, 83<br />

Environmental Noise 120, 122<br />

Explosion 90<br />

Flow 110-111<br />

Ground Vibration 90<br />

Humidity 70, 72-73<br />

Oven 70<br />

Pressure 102<br />

Shipping & Transport 89<br />

Temperature 70-73<br />

Logic Analyser 10<br />

Logic Programmer 10<br />

Low Frequency<br />

Frequency Response Analysers 10<br />

Signal Generator 26<br />

Luminance Meter 119<br />

Lux Meter 119<br />

m<br />

Machinery<br />

Balancing 88<br />

Vibration 88-89<br />

Magnetic Field Meter 40<br />

Manometer 114-115<br />

Materials Testing 86, 128, 131<br />

Memory Recorder 73-75<br />

Metal Detector 106-107<br />

Methane Monitor 123, 127<br />

Micro-Ohm Meter 41-43<br />

GENERAL INDEX<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 135


GENERAL INDEX<br />

136<br />

Microscope 82<br />

Microwave Leakage Detector 19-20<br />

Microwave Oven Survey Meter 19-20<br />

Modified Atmosphere<br />

packaging Test 123, 127<br />

Modulation Meter 20<br />

Moisture<br />

Concrete 92-93<br />

Timber 92<br />

Moisture Balance 87<br />

Multimeter 5-6<br />

n<br />

Natural Gas 105<br />

Network Analyser<br />

Antenna & Cable Test 18-19<br />

LAN/WAN 29<br />

power 48-49<br />

RF 13, 18, 26<br />

Telecommunications 28<br />

Noise & Sound 120<br />

Noise Dose Meter 120-121<br />

Noise Logger 120, 122<br />

Non-Destructive Testing<br />

(NDT) 88, 90-92<br />

Non-Storage Oscilloscope 3<br />

O<br />

Occupational Health & Safety 119, 122<br />

Air Quality 113-114, 117<br />

Appliance Testing 46-47<br />

Confined Space Entry 123, 125-126<br />

Floor Slip Tester 122<br />

Formaldehyde 123, 125<br />

Heat Stress 113-114, 117<br />

Lighting 119<br />

Noise & Sound 120<br />

Ozone 123, 125<br />

Radiation 19-20<br />

Toxic Gas 123, 125, 127<br />

UV Exposure 119<br />

Vibration 88<br />

Oil Insulation Tester 41, 46<br />

Optical Networking<br />

DWDM 35<br />

Optical Spectrum Analysis 35<br />

Oscilloscopes<br />

Digital Storage 2-3<br />

Non Storage 3<br />

portable 2-3<br />

probes 4<br />

OTDR 34<br />

Oven 101<br />

Oven Logger 70<br />

Oxygen & CO 2 Analyser 123, 125, 127<br />

Oxygen (O 2 ) 123, 125, 127<br />

Ozone (O 3 ) 123<br />

Ozone Monitor 123<br />

p<br />

particle Counter 113-114, 117<br />

pAT 46, 47<br />

PCM Test Equipment 28<br />

pDH Analyser 28<br />

People Counter 107<br />

Petrol Generator 68<br />

pH Measurement 128<br />

phase Angle 63<br />

Phase Rotation Meter 63<br />

Phase Sequence Meter 63<br />

photo-Ionisation Detector (pID) 123, 127<br />

Pinhole Detector 91<br />

Pipe Locators 36<br />

Pipeline Inspection 79<br />

Pitot Tube 115<br />

Plotter Printer 76<br />

Polarisation Mode Dispersion (PMD) 35<br />

portable Appliance Tester 46, 47<br />

position Transducer 84<br />

POTS 28<br />

Power See Electrical<br />

power Analyser 48-49, 51-56, 63<br />

Power Demand<br />

Analyser 48-49, 51-54, 56<br />

power Disturbance 48-49, 51, 56<br />

Power Line Conditioner 66<br />

power Supplies - DC 7<br />

Pressure<br />

Calibrator 94-95, 97-100<br />

Circular Chart Recorder 82-83<br />

Indicator/Gauge 77, 82-83<br />

Transducer 77, 83<br />

Probe<br />

Current 4, 48-51, 57, 61-62<br />

Digital 75<br />

Frame Relay 31<br />

High Voltage 4<br />

Line Logic 75<br />

Static Detector 6<br />

process Calibrator 96-98<br />

Programmer<br />

EPROM, EEPROM 10<br />

Protection Relay Test 57<br />

protocol Analyser 28, 30-31<br />

Pulse Crest Meter 91<br />

Pulse Generator 9<br />

Pulse Porosity Detector 91<br />

pump 94-95, 98-100<br />

r<br />

Radar Speed Gun 78<br />

Radiation Monitor 19-20<br />

Radiometer 119<br />

Random Noise Generator 26<br />

RCD Test 41, 45<br />

Recorders 70<br />

Barometric 102<br />

Chart 76, 82-83<br />

Hybrid 76<br />

Memory 73-75<br />

Pressure 82, 83<br />

Tape 76<br />

Temperature Humidity 72<br />

Rectifier 7<br />

Refrigerant Leak Detection 118<br />

Relative Humidity 102<br />

Also See Humidity<br />

Relay Test 57, 65<br />

Resistance<br />

Calibration 94-95<br />

Decade 9<br />

Ground/Soil 45-46<br />

Micro-Ohm 41-43<br />

Static 41, 46<br />

Tester 41-46<br />

Retail Traffic Flow Counter 107<br />

RF & Microwave<br />

Accessories 26<br />

Amplifier 13<br />

Antenna/SWR 18-19<br />

Antennas 18-20<br />

Attenuator 25-26<br />

Communications Test Set 21<br />

EMC/EMI Test 14, 17, 20-21<br />

Field Strength Meters 19-20<br />

Frequency Counter 12<br />

Function Generator 8<br />

Modulation Meter 20<br />

Network Analyser 13, 18-19<br />

power Meter 22-23<br />

power Sensors 24<br />

Radiation Monitor 19-20<br />

Sensor 22, 24<br />

Signal Generator 13, 20<br />

Spectrum Analyser 10, 14, 17<br />

Sweep Generator 13<br />

Voltmeter 22<br />

Rogowski Coil 48-49, 53<br />

Rotating Balancing 89<br />

Rotating Laser Level 78<br />

Roughness 91<br />

Router Test System 31<br />

RTD Calibrator 94-95<br />

S<br />

Salinity & Conductivity 129<br />

Scales 85-87<br />

Scopemeter 2-3<br />

Security<br />

Bug Detector 106<br />

Metal Detector 106<br />

Surveillance 106<br />

Shaft Alignment 88-89<br />

Shaker Table 88, 90<br />

Signal Generator<br />

Low Frequency 26<br />

RF 13<br />

Signalling Analyser 28<br />

Smoke Generating Machine 114<br />

Sniffer 30<br />

Soil Resistivity 41, 46<br />

Sonde 37<br />

Sound 120<br />

Dose Meter 120-121<br />

Logger 120-122<br />

Measurement 120<br />

Signal Analysis 119<br />

Sound Level Meter 88-89, 120-122<br />

Vibration 88-89<br />

Spectrophotometer 130-131<br />

Spectroscopy 131<br />

Spectrum Analyser<br />

Acoustic 119<br />

Optical 35<br />

RF 10, 14-15, 17<br />

Speed Measurement 78<br />

Splicer - Fibre Optic 35<br />

SS7 28<br />

Startup Current 48-49, 51-54<br />

Static Detector Probe 6<br />

Static Discharge Generator 21<br />

Step Transformer 21<br />

STM1 ... STM65 28, 31<br />

Strip Chart Recorder 76<br />

Stroboscopes 78-79<br />

Surface Roughness 91<br />

Surge Generator 36<br />

Surge Transient Generator<br />

EMC/EMI Test 21<br />

Survey Equipment 78<br />

Sweep Generator 13<br />

t<br />

Tachometers 78-79<br />

Tape Recorders 76<br />

TDR 36-37<br />

Telecommunications<br />

BERT 28<br />

CDMA 23<br />

Communications Analyser 28<br />

Fibre Optics 33-34<br />

GSM 28<br />

ISDN 28<br />

PDH 28<br />

POTS 28<br />

SDH 28<br />

Signalling Analyser 28<br />

System Tools 28<br />

WAN analyser 31<br />

W-CDMA 23<br />

Temperature<br />

IR Thermometer 102-103<br />

Logging 72-73, 130<br />

Recorders 102<br />

Thermocouple 102-103<br />

Thermometer 102-103<br />

Tension 85<br />

Thermal Imaging Camera 104-105<br />

Thermocouple 102-103<br />

Thermohygrograph 102<br />

Time Domain Reflector<br />

TDR 36-37<br />

Token Ring Analyser 30<br />

Torque Wrench 84<br />

Total Dissolved Solids (TDS) 129<br />

Toxic Gas Monitor 123, 125, 127<br />

Transducers<br />

Current 53, 60, 63<br />

Electrical 60, 62<br />

Frequency 60-63<br />

Humidity 77, 83-84<br />

Instrument Transformer 60, 62<br />

position 84<br />

pressure 77, 82-83<br />

Temperature 77, 83-84<br />

Voltage 60, 62-63<br />

Transformer Oil Test 46<br />

Transient Burst 21<br />

Transport<br />

Inclinometers 84<br />

Turbidity 128-130<br />

TV Test Equipment 27<br />

u<br />

Ultrafine particle Counter 113-114, 117<br />

Ultrasonic bath 100<br />

Uninterruptable power Supplies<br />

- UpS 66-67<br />

UV Exposure 119<br />

v<br />

V24, V35 31<br />

Valve balancing (Air Conditioning) 118<br />

Vane Anemometer 113-115<br />

Variacs 67<br />

VCR 82, 106<br />

Vibration<br />

Accelerometer 88-89<br />

Analyser 88-89<br />

Blast Logging 90<br />

Impact Hammer 89<br />

Logging 89-90<br />

Table 88, 90<br />

Transport Testing 89<br />

Whole Body 88<br />

Video<br />

Endoscope 81<br />

High Speed 82<br />

Microscope 82<br />

pipeline Inspection 79-81<br />

Video Camera<br />

Digital 106<br />

VHS 82, 106<br />

Video Security 106<br />

Viscometer 86, 131<br />

VLF MV Cable Test 59<br />

Volatile Organic Compounds<br />

(VOC) 123, 127<br />

Voltage Calibrator 94-95<br />

Voltage Transducer 60, 62<br />

Voltmeter 6, 22<br />

W<br />

Walk Through Metal Detector 106<br />

WAN Analysers 29-31<br />

Water<br />

Analysis 130<br />

Conductivity 129<br />

Depth 110-111, 129-130<br />

Flow 110-111<br />

Leakage Detection 37<br />

pH 128-129<br />

Quality 128-129<br />

Sampling 130<br />

Water/Oil bath Temp Calibrator 94-95, 97<br />

Waveform Generator 8<br />

WbGT 113-114, 117<br />

Weather 118<br />

Wind Speed & Direction 117-118<br />

Workplace Safety<br />

See Occupational Health & Safety<br />

x<br />

x.21, x.24 30-31<br />

x-Ray Measurement 19-20


YOUR <strong>TR</strong>USTED PARTNER IN TECHNOLOGY<br />

OFFERING INNOVATIVE <strong>SOLUTIONS</strong> THROUGH<br />

OUR LEADING BRANDS:


AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my<br />

YOUR <strong>TR</strong>USTED PARTNER IN TECHNOLOGY.<br />

OFFERING INNOVATIVE <strong>SOLUTIONS</strong> THROUGH OUR<br />

LEADING BRANDS:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!