RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TEST & MEASUREMENT<br />
<strong>RENTAL</strong> <strong>SOLUTIONS</strong> <strong>GUIDE</strong> <strong>2007</strong><br />
VOLUME 32 ISSUE 12<br />
>ELEC<strong>TR</strong>ONICS & DATA >ELEC<strong>TR</strong>ICAL POWER >GENERAL INDUS<strong>TR</strong>IAL >ENVIRONMENTAL >CALIBRATION
TEST & MEASUREMENT <strong>RENTAL</strong> <strong>SOLUTIONS</strong><br />
SpecialiSed<br />
equipment<br />
rental<br />
rental<br />
purchaSe<br />
OptiOn<br />
cOnvenient<br />
Office<br />
lOcatiOnS<br />
delivery &<br />
Setup<br />
expert<br />
advice<br />
frOm 1<br />
day tO<br />
lOng<br />
term<br />
calibratiOn<br />
ServiceS
WELCOME<br />
We are pleased to bring you the <strong>2007</strong> edition of our<br />
Rental Solutions Guide, showcasing our extensive<br />
inventory of test and measurement equipment covering<br />
Data Communications, RF Telecommunications,<br />
Electrical Power, Environmental and General Industrial.<br />
TechRentals have been helping solve test and<br />
measurement problems for over 32 years and in the<br />
past 12 months our organisation has seen significant<br />
changes, which have only enhanced our ability to assist.<br />
New offices in regional Australia in places like Devonport<br />
and Karratha, plus new locations in New Zealand<br />
and Malaysia are helping us deliver our solutions<br />
to the world.<br />
This new edition of our guide includes numerous<br />
new products and models, also highlighting our<br />
equipment calibration capabilities via our sister<br />
company VMS; Australia’s leading group of NATA<br />
certified calibration laboratories.<br />
We look forward to assisting you with your test and<br />
measurement needs and hope you will find this guide<br />
a useful resource.<br />
The TechRentals Team<br />
TechRentals Information ii<br />
Office Locations iv<br />
Quick Find Solution Guide vi<br />
>ELEC<strong>TR</strong>ONICS & DATA 1<br />
General Electronic Test Equipment 2<br />
RF & Microwave 13<br />
Low Frequency 26<br />
TV Test Equipment 27<br />
Data, Network<br />
& Telecommunications 28<br />
Cable/Pipe Testers & Locators 36<br />
>ELEC<strong>TR</strong>ICAL POWER 39<br />
Magnetic Field Meters 40<br />
Insulation & Resistance Testers 41<br />
Power Quality Analysers 48<br />
Projection Relay Testing Systems 57<br />
AC/DC Hi Pot Testers 59<br />
Electrical Transducers 60<br />
Current Injectors - Primary & Secondary 65<br />
Power Line Conditioners & UPS 66<br />
AC Power 68<br />
>GENERAL<br />
INDUS<strong>TR</strong>IAL 69<br />
Data Acquisition & Recording 70<br />
Physical Measurement 77<br />
Non-Destructive Testing 88<br />
General Industrial 94<br />
Temperature<br />
& Humidity Measurement 102<br />
Security Equipment 106<br />
>ENVIRONMENTAL 109<br />
Flow Meters 110<br />
Air Conditioning<br />
& Air Quality - HVAC & IAQ 113<br />
Occupational Health & Safety 119<br />
Gas Analysis & Monitoring 123<br />
General Environment 128<br />
Laboratory 131<br />
>CALIBRATION 133<br />
General Index 135
TECH<strong>RENTAL</strong>S<br />
prOviding SOlutiOnS<br />
For 32 years, TECH<strong>RENTAL</strong>S has been providing rental<br />
solutions across Australasia. When you need to test,<br />
measure or record, we will assist with expert advice, flexible<br />
rental options and the right technology to get the job done.<br />
When you need the job done right, first time, talk to us.<br />
Why yOu ShOuld uSe techrentalS<br />
cOnvenient lOcatiOnS<br />
Our customers have access to over 30 <strong>TR</strong> <strong>Corporation</strong> locations across Australia,<br />
New Zealand and Malaysia. Locations range from small technical offices in remote<br />
areas such as Karratha in the mining hub of Western Australia to sophisticated<br />
calibration laboratories in Sydney and Brisbane, and our fully equipped <strong>TR</strong> <strong>Corporation</strong><br />
headquarters in Melbourne.<br />
vaSt inventOry Of SpecialiSed equipment<br />
With more than 10,000 items in stock, we’re bound to have the gear you need, no<br />
matter what your industry or project. New products are continually being added to our<br />
inventory as technology evolves. Local government regulations may apply to the use of<br />
some equipment in this catalogue, please contact your local office for more information.<br />
the lateSt prOductS frOm WOrld claSS brandS<br />
We stock the latest gear from leading manufacturers including FLUKE, AGILENT,<br />
HIOKI, ANRITSU, MEGGER, YOKOGAWA and more.<br />
expert advice<br />
Our team of technical sales people are highly experienced, most with extensive industry<br />
backgrounds. They’re friendly, reliable and knowledgeable with a “can do” attitude.<br />
Simple quOting<br />
Our rapid quoting system means you are only a phone call or “mouse click” away.<br />
Get online and select the equipment you need, or call and discuss your specific<br />
requirements with our team for a quick and accurate estimate.<br />
flexible rental termS<br />
Whether it’s for a day, a week, a year, or you wish to rent-to-own, TECH<strong>RENTAL</strong>S can<br />
assist. And if your project is extended, it’s no problem. Simply call and we’ll amend the<br />
rental contract.<br />
reSpOnSive delivery & Setup<br />
You need equipment fast and at the right place, at the right time, and ready to go.<br />
Equipment is delivered in purpose-built protective containers, in tiptop condition and<br />
with easy to understand instructions.<br />
OptiOnS<br />
Other options are available to complement your rental needs including data download,<br />
trained operators to manage the task for you, customised equipment programming and<br />
even total asset management.<br />
nO riSk guarantee<br />
And if the unusual occurs and the gear isn’t up to the job, return it within 24 hours to<br />
receive a refund on the rental charge.<br />
part Of tr cOrpOratiOn<br />
In 2005, TechRentals became part of a larger family with the formation of <strong>TR</strong><br />
<strong>Corporation</strong>. Each subsidiary is a leading brand offering a specialised technology<br />
solution for industry. Our group capabilities now include radio communications, audio<br />
visual & business equipment, calibration, wireless connectivity solutions and mining<br />
communications. Our customers range from mining companies in Poland and Chile<br />
to a small electrical contractor in Christchurch, New Zealand - making us a truly global<br />
technology supplier.
delivering<br />
benefitS<br />
Whether you’re part of<br />
a major multinational<br />
or a small-to-medium<br />
enterprise, equipment<br />
rental makes good<br />
business sense offering<br />
a range of economic and<br />
practical benefits.<br />
Avoid the headaches and<br />
talk to us.<br />
ECONOMICAL<br />
FLEXIBLE<br />
ACCESSIBLE<br />
Free up capital<br />
Recover costs<br />
more quickly<br />
Control costs<br />
more efficiently<br />
Eliminate running costs<br />
Conduct product<br />
research before<br />
purchases<br />
Apply new technologies<br />
& avoid obsolescence<br />
Respond to<br />
sudden demands<br />
Seek help from<br />
the experts<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
Why yOu ShOuld rent<br />
financial benefitS<br />
CONSERVE YOUR CApITAL: Industrial equipment is expensive and can spend much<br />
of its time unused, collecting dust and delivering no return on investment. By renting<br />
the equipment that you only need occasionally, you can release your organisation’s<br />
capital to invest in other parts of the business.<br />
RECOVER YOUR COSTS: Generally, rental payments are fully tax deductible, and<br />
the expense can be recouped far quicker than tax allowances for ongoing asset<br />
depreciation.<br />
S<strong>TR</strong>EAMLINE YOUR ACCOUNTS: Equipment is often required for a particular client,<br />
project or location. Renting allows you to control your financials more effectively and<br />
simplifies the process of allocating costs to internal departments or third-parties.<br />
WIpE OUT RUNNING COSTS: The expense of maintaining, calibrating and<br />
warehousing equipment can be high. By renting equipment, you avoid these costs and<br />
potentially free-up valuable space within your premises.<br />
OperatiOnal benefitS<br />
<strong>TR</strong>Y bEFORE YOU bUY: It’s not always clear which equipment make and model will<br />
fulfil your requirements. A short term rental can give you the hands-on experience you<br />
need to guide purchase decisions.<br />
KEEp Up WITH THE TIMES: businesses are constantly evolving to keep pace with<br />
new technologies. Rental allows you to update your equipment in line with other<br />
business and industry changes and avoid the risk of accommodating costly dinosaurs.<br />
CATER TO THE UNExpECTED: At peak periods or when essential equipment breaks<br />
down, rental can put the necessary equipment in your hands ensuring seamless<br />
operations.<br />
REFER TO THE ExpERTS: Should you experience difficulties with rented equipment,<br />
it’s not your problem. Simply call TechRentals for free professional equipment advice<br />
and support.<br />
OptiOn tO OWn<br />
TechRentals offers approved business<br />
customers a unique rental solution<br />
with option to own schemes.<br />
Whether it’s the latest power analyser<br />
or a humidity chamber, the option of<br />
ownership offers flexibility should a<br />
stopgap measure turn into a long term<br />
or permanent need.<br />
After a mutually agreed minimum<br />
rental period (typically 12 months),<br />
the equipment may be purchased<br />
by paying an amount equal to one<br />
month’s rental. After a specified<br />
number of payments, the equipment<br />
is yours!<br />
For more information about option to<br />
own schemes, please call your local<br />
TECH<strong>RENTAL</strong>S office.<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my<br />
WHY BUY WHEN YOU CAN RENT?
LOCATIONS<br />
v<br />
With locations across<br />
Australia, New<br />
Zealand and Malaysia,<br />
TECH<strong>RENTAL</strong>S have<br />
all your Test and<br />
Measurement problems<br />
covered<br />
auStralia<br />
adelaide<br />
81-83 Stephens Avenue<br />
Torrensville South Australia 5031<br />
P +61 8 8302 8800<br />
F +61 8 8302 8899<br />
briSbane<br />
Unit 1 46 Longland Street<br />
Newstead Queensland 4006<br />
P +61 7 3850 7700<br />
F +61 7 3850 7799<br />
darWin<br />
Unit 3 101 Coonawarra Road<br />
Winnellie Northern Territory 0820<br />
p +61 8 8947 2860<br />
F +61 8 8947 2901<br />
devOnpOrt<br />
53 Don Road<br />
Devonport Tasmania 7310<br />
p +61 3 6422 6000<br />
F +61 3 6424 3994<br />
gOld cOaSt<br />
103-105 Spencer Road<br />
Nerang Queensland 4211<br />
p +61 7 5596 3451<br />
F +61 7 5596 4119<br />
karratha<br />
33B Gawthorne Drive<br />
Karratha Western Australia 6714<br />
P +61 8 9185 6871<br />
F +61 8 9441 3999<br />
melbOurne<br />
6 Joseph Street<br />
blackburn North Victoria 3130<br />
P +61 3 9896 3000<br />
F +61 3 9896 3099<br />
neWcaStle<br />
Unit 2 1 Hartley Drive<br />
Thornton New South Wales 2322<br />
p +61 2 4966 5910<br />
F +61 2 4966 3586<br />
perth<br />
122 Kewdale Road<br />
Kewdale Western Australia 6105<br />
p +61 8 9441 3900<br />
F +61 8 9441 3999<br />
pOrt melbOurne<br />
Unit 11 484 Graham Street<br />
Port Melbourne Victoria 3207<br />
P +61 3 9896 3000<br />
F +61 3 9896 3099<br />
Sydney<br />
Metro Centre Unit 13<br />
38-46 South Street<br />
Rydalmere New South Wales 2116<br />
P +61 2 9933 1100<br />
F +61 2 9933 1199<br />
tOWnSville<br />
Unit 8 15-17 Castlemaine Street<br />
Kirwin Queensland 4817<br />
p +61 7 4773 7788<br />
F +61 7 4723 5397<br />
vmS - calibratiOn,<br />
repair & Service<br />
melbOurne<br />
6 Joseph Street<br />
blackburn North Victoria 3130<br />
P +61 3 9896 3000<br />
F +61 3 9896 3099<br />
cOOperS plainS<br />
Unit 1&4 30 Lensworth Street<br />
Coopers plains Queensland 4108<br />
p +61 7 3344 1866<br />
F +61 7 3344 1744<br />
milperra<br />
Unit 34 244 Horsley Road<br />
Milperra New South Wales 2214<br />
P +61 2 9771 9300<br />
F +61 2 9711 9600
neW zealand malaySia<br />
auckland<br />
669 Great South Road<br />
penrose Auckland New Zealand<br />
p +64 9 589 2030<br />
F +64 9 589 2031<br />
hamiltOn<br />
4/11 pukete Road<br />
Te Rapa Hamilton New Zealand<br />
p +64 7 849 0674<br />
F +64 7 849 0676<br />
WellingtOn<br />
71 Hutt Road<br />
Wellington New Zealand<br />
p +64 4 384 4833<br />
F +64 4 384 4677<br />
chriStchurch<br />
540 Wairakei Road<br />
Christchurch New Zealand<br />
p +64 3 338 1188<br />
F +64 3 338 7100<br />
Other tr cOrpOratiOn<br />
lOcatiOnS in neW zealand:<br />
bearcOm<br />
cOmmunicatiOnS<br />
Auckland<br />
Hamilton<br />
Wellington<br />
Christchurch<br />
vidcOm<br />
audiO viSual<br />
Auckland<br />
Tauranga<br />
Hamilton<br />
Rotorua<br />
Christchurch<br />
Queenstown<br />
Dunedin<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
kuala lumpur<br />
38 Jalan pJS 11/3 bandar Sunwa<br />
46150 petaling Jaya<br />
Selangor Darul Ehsan Malaysia<br />
P +60 3 5632 1135<br />
F +60 3 5632 5409<br />
penang<br />
b-4-23 Krystal point<br />
303 Jalan Sultan Azlan Shah<br />
Sungai Nibong<br />
11900 Penang Malaysia<br />
p +604 642 6318<br />
F +604 642 2035<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
LOCATIONS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my v
QUICK FIND SOLUTION <strong>GUIDE</strong><br />
v<br />
agriculture maintenance<br />
& management<br />
chemical analysis 131<br />
data logging 70<br />
environmental testing 123<br />
humidity measurement 113-114<br />
light & UV measurement 119<br />
liquid & gas flow measurement 110<br />
microscopes 82<br />
pressure measurement 77, 83<br />
temperature measurement 102<br />
weather recording 118<br />
air cOnditiOning & refrigeratiOn -<br />
maintenance<br />
air conditioning system balancing 118<br />
air flow measurement 113-114<br />
air quality testing 113-114<br />
data logging 70<br />
dust detection 113-114<br />
gas analysis & monitoring 123<br />
gas leakage detectors 118<br />
humidity measurement 77, 83<br />
liquid & gas flow measurement 110<br />
noise analysis 120<br />
pressure measurement 82-83<br />
temperature measurement 102<br />
temperature/humidity/barometric<br />
recording 102<br />
vibration measurement 88<br />
autOmOtive engineering & deSign<br />
air flow measurement 113-114<br />
air quality testing 113-114<br />
data logging 70<br />
dc power supplies 7<br />
electrical insulation testing 41<br />
endoscopes 79<br />
force gauges 84<br />
gas analysis & monitoring 123<br />
high speed video recording 82<br />
humidity measurement & recording 102<br />
instrumentation amplifiers 73<br />
light & UV measurement 119<br />
liquid & gas flow measurements 110<br />
microscopes 82<br />
noise analysis 120<br />
non-destructive testing (NDT) 88<br />
pressure & vacuum<br />
measurement 82-83<br />
tachometers & stroboscopes 78<br />
temperature measurement<br />
& recording 102<br />
thermal imaging camera 104<br />
vibration measurement 88<br />
building & cOnStructiOn<br />
ac power sources/inverters<br />
/generators 68<br />
air flow measurement 113-114<br />
air quality testing 113-114<br />
cable & pipe location 36<br />
cable integrity testing 36<br />
concrete testing 90-93<br />
distance measurement 78<br />
electrical insulation testing 41<br />
endoscopes 79<br />
gas analysis & monitoring 123<br />
hardness testing 93<br />
humidity & moisture measurement 105<br />
light & UV measurement 119<br />
liquid & gas flow measurement 110<br />
load measurement 85<br />
noise measurement 120<br />
non-destructive testing (NDT) 88<br />
pressure measurement 82-83<br />
security equipment 106<br />
temperature/humidity/barometric<br />
recorders 102<br />
thermal imaging cameras 104<br />
vibration measurement 88<br />
weather recording 118<br />
buSineSS & Office equipment<br />
ac generators & UpS 66<br />
network test equipment 29<br />
security equipment 106<br />
chemical analySiS<br />
air quality measurement 113-114<br />
ground water logging 128<br />
salinity testing 128<br />
spectrophotometers 131<br />
water quality testing 128<br />
data cOmmunicatiOnS<br />
ac generators & UpS 66<br />
dc power supplies 7<br />
fibre optics cable testing & splicing 33<br />
LAN analysis and management 29<br />
LAN cable testing 32<br />
WAN analysis & management 31<br />
defence pOlice fire & emergency<br />
ac generators & UpS 66<br />
ac power sources/inverters/<br />
generators 68<br />
air flow measurement 113-114<br />
air quality 113-114<br />
cable pipe testing & location 36<br />
data logging 70<br />
endoscopes 79<br />
environmental - testing 123<br />
gas analysis & monitoring 123<br />
high speed video capture 82<br />
light & UV measurement 119<br />
microscopes 82<br />
noise & vibraton analysis 120<br />
non-destructive testing (NDT) 88<br />
sound signal analysis 119<br />
spectroscopy 131<br />
temperature measurement 102<br />
thermal imaging cameras 104<br />
TV test equipment 27<br />
weather recording 118<br />
educatiOn<br />
security & surveillance equipment 106<br />
electrical – induStrial & dOmeStic<br />
ac generators & UpS 66<br />
ac power analysis & recording 40<br />
ac power sources/inverters/<br />
generators 68<br />
cable pipe testing & location 36<br />
current injection 64<br />
data logging 70<br />
dc power supplies 7<br />
digital storage oscilloscope 2<br />
electrical calibrators 9<br />
electrical transducers 60<br />
field strength measurement 19<br />
general electrical testing 63<br />
high voltage testing 4, 59<br />
instrumentation amplifiers 73<br />
insulation testing 40<br />
magnetic field measurement 40<br />
multimeters & electrometers 5<br />
power transformers 67<br />
temperature measurement 102<br />
thermal imaging cameras 104<br />
voltage current recording 76<br />
emergency ServiceS<br />
ac generators & UpS 66<br />
ac power sources/inverters/<br />
generators 68<br />
air flow measurement 113-114<br />
air quality 113-114<br />
cable pipe testing & location 36<br />
data logging 70<br />
endoscopes 79<br />
environmental - testing 123<br />
gas analysis & monitoring 123<br />
high speed video capture 82<br />
light & UV measurement 119<br />
microscopes 82<br />
noise & vibraton analysis 120<br />
non-destructive testing (NDT) 88<br />
RF & microwave testing equipment 13<br />
sound signal analysis 119<br />
spectroscopy 131<br />
temperature measurement 102<br />
thermal imaging cameras 104<br />
TV test equipment 27<br />
weather recording 118<br />
envirOnmental teSting<br />
air flow measurement 113-114<br />
air quality measurement 113-114<br />
data logging 70<br />
electrochemistry 128<br />
gas analysis & monitoring 123<br />
humidity & moisture measurement 105<br />
light & UV measurement 119<br />
liquid & gas flow measurement 110<br />
noise & sound 120<br />
spectroscopy 131<br />
temperature measurement 102<br />
temperature/humidity/barometric<br />
recorders 102<br />
thermal imaging cameras 104<br />
vibration analysis 88<br />
water quality testing 128<br />
weather recording stations 118<br />
event management<br />
metal detectors 107<br />
security & surveillance 106
fOOd manufacturing<br />
air quality monitoring 113-114<br />
endoscopes 79<br />
high speed video capture 82<br />
humidity measurement & logging 102<br />
metal detectors 106<br />
moisture meters 105<br />
process control test equipment 94-95<br />
scales & balances 87<br />
temperature measurement<br />
& logging 102<br />
water quality testing 128<br />
gaS induStry<br />
cable pipe testing & location 36<br />
data logging 70<br />
gas analysis & monitoring 123<br />
high speed video capture 82<br />
humidity & moisture measurement 105<br />
liquid & gas flow measurement 110<br />
non-destructive testing (NDT) 88<br />
OH&S & environmental testing<br />
- general 122<br />
pressure vacuum gauges<br />
& recorders 82-83<br />
spectroscopy 131<br />
thermal imaging cameras 104<br />
voltage current recording 76<br />
general electrOnicS teSt equipment<br />
data logging 70<br />
dc power supplies 7<br />
digital storage oscilloscopes 2<br />
distortion analysers 26<br />
electrical calibrators 9<br />
EMC test equipment 21<br />
field strength meters & antennas 19<br />
frequency counters 12<br />
frequency response analysers 10<br />
function generators 8<br />
instrumentation amplifiers 73<br />
LCR meters 9<br />
LF signal generators 26<br />
logic/analysers/testers 10<br />
memory recorders 73<br />
multimeters & electrometers 5<br />
non-storage oscilloscopes 3<br />
probes & accessories 4<br />
PROM programmers 10<br />
pulse generators 9<br />
strip chart recorders 76<br />
tape recorders 76<br />
TV test equipment 27<br />
ultrasonic baths 100<br />
voltage current recorders 76<br />
health & Safety<br />
air flow measurement 113-114<br />
air quality measurement 113-114<br />
data logging 70<br />
electrical insulation testing 41<br />
electrochemistry 128<br />
gas analysis & monitoring 123<br />
light & UV measurement<br />
magnetic field measurement<br />
119<br />
– Gauss Tesla<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
40<br />
noise & sound analysis 120<br />
OH&S & environmental compliance<br />
testing 122<br />
vibration analysis 88<br />
water quality measurement 128<br />
it departmentS<br />
ac generators & UpS 66<br />
air conditioning testing 113-114<br />
air flow measurement 113-114<br />
cable location 36<br />
data comms test equipment<br />
– LAN/WAN 31<br />
security & surveillance equipment 106<br />
temperature measurement<br />
& recording 102<br />
lOcal gOvernment<br />
ac generators & UpS 66<br />
air flow measurement 113-114<br />
air quality testing 113-114<br />
cable pipe testing & location 36<br />
concrete testing equipment 90<br />
data logging 70<br />
electrical insulation testing 41<br />
electrical testers 63<br />
electrochemistry 128<br />
gas analysis 123<br />
LAN analysis & monitoring 29<br />
LAN/WAN analysers 31<br />
light & UV measurement 119<br />
magnetic field meters 40<br />
noise & sound analysis 120<br />
OH&S & environmental equipment 122<br />
temperature measurement 102<br />
thermal imaging cameras 104<br />
vibration analysis 88<br />
WAN analysers 31<br />
water quality testing 128<br />
manufacturing & prOceSS induStry<br />
ac generators & UpS 66<br />
cable pipe testing & location 36<br />
data logging 70<br />
distance mesurement 78<br />
endoscopes 79<br />
gloss mesurement 90<br />
hardness testing 93<br />
high speed video capture 82<br />
humidity & moisture measurement 105<br />
inclinometers 84<br />
light & UV measurement 119<br />
liquid & gas flow mesurement 110<br />
materials testing 86, 128, 131<br />
memory recorders 73<br />
microscopes 82<br />
noise & sound analysis 120<br />
non-storage oscilloscopes 3<br />
OH&S & environmental - general 122<br />
position transducers 84<br />
pressure & humidity<br />
measurement 77, 83<br />
pressure vacuum measurement 82-83<br />
PROM programmers 10<br />
scales & balances 87<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
strip chart recorders 76<br />
tachometers/stroboscopes 78<br />
tape recorders 76<br />
temperature measurement 102<br />
temperature/humidity recorders 102<br />
thermal imaging cameras 104<br />
vibration analysis 88<br />
marine<br />
dc & ac power testing 40<br />
endoscopes 79<br />
liquid & gas flow measurement 110<br />
non-destructive testing (NDT) 88<br />
see ‘general electronics test equipment’<br />
mining & explOratiOn<br />
ac generators & UpS 66<br />
air flow measurement 113-114<br />
air quality measurement 113-114<br />
cable pipe testers & locators 36<br />
data logging 70<br />
dc power supplies 7<br />
distance measurement & surveying 78<br />
electrochemistry 128<br />
endoscopes 79<br />
force measurement 84<br />
gas analysis 123<br />
high speed video capture 82<br />
humidity & moisture measurement 105<br />
inclinometers 84<br />
light & UV measurement 119<br />
liquid & gas flow measurement 110<br />
load measurement 85<br />
Logic analysers & testers 10<br />
memory recorders 73<br />
microscopes 82<br />
noise & sound analysis 120<br />
non-destructive testing (NDT) 88<br />
OH&S & environment compliance<br />
testing 122<br />
power analysis & recording 40<br />
pressure & humidity<br />
measurement 77, 83<br />
pressure vacuum gauges<br />
/recorders 82-83<br />
protection relay testing 57<br />
RF amplifiers 13<br />
RF signal generators 13<br />
RF sweep generators 13<br />
spectroscopy 131<br />
strip chart recorders 76<br />
telecommunications testing 21<br />
temperature measurement 102<br />
temperature/humidity/barometric<br />
measurement 102<br />
thermal imaging cameras 104<br />
vibration & alignment analysis 88<br />
weather monitoring & recording 118<br />
nOn-deStructive teSting<br />
acceleration measurement 88<br />
cover meters 92<br />
gloss measurement 90<br />
hardness testing 93<br />
liquid & gas flow measurement 110<br />
QUICK FIND SOLUTION <strong>GUIDE</strong><br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my v
QUICK FIND SOLUTION <strong>GUIDE</strong><br />
v<br />
shock testing 88<br />
thickness measurement 90<br />
vibration measurement 88<br />
OccupatiOnal health & Safety<br />
air flow measurement 113-114<br />
air quality measurement 113-114<br />
data logging 70<br />
electrical insultation testing 41<br />
electrochemistry 128<br />
gas analysis & monitoring 123<br />
light & UV measurement 119<br />
magnetic field measurement<br />
– Gauss Tesla 40<br />
noise & sound analysis 120<br />
OH&S & environment compliance<br />
testing 122<br />
vibration analysis 88<br />
water quality measurement 128<br />
petrOchemical<br />
data logging 70<br />
electrochemistry 128<br />
force measurement 84<br />
gas analysis & monitoring 123<br />
high speed video capture 82<br />
liquid & gas flow measurement 110<br />
load measurement 85<br />
memory recorders 73<br />
microscopes 82<br />
non-destructive testing (NDT) 88<br />
pressure & humidity<br />
measurement 77, 83<br />
pressure vacuum gauges<br />
/recorders 82-83<br />
strip chart recorders 76<br />
tachometers/stroboscopes 78<br />
temperature measurement 102<br />
thermal imaging cameras 104<br />
vibration & alignment analysis 88<br />
water quality measurement 128<br />
plumbing & gaSfitting<br />
see ‘water waste water & plumbing’ section<br />
pOWer generatiOn & diStributiOn<br />
cable pipe testers & locators 36<br />
combustion gas analysis<br />
& monitoring 124-125<br />
current injectors 64<br />
data logging 70<br />
distance measurement & surveying 78<br />
endoscopes 79<br />
force measurement 84<br />
hi pot testing 59<br />
high speed video capture 82<br />
humidity & moisture measurement 105<br />
inclinometers 84<br />
insulating testing 41<br />
LCR meters 9<br />
liquid & gas flow measurement 110<br />
load measurement 85<br />
magnetic field measurement<br />
– Gauss Tesla 40<br />
noise & sound analysis 120<br />
non-destructive testing (NDT) 88<br />
power analysis & recording 40<br />
protection relay testing 57<br />
strip chart recorders 76<br />
tachometers/stroboscopes 78<br />
temperature/humidity/barometric<br />
measurement 102<br />
thermal imaging cameras 104<br />
vibration & alignment analysis 88<br />
voltage current recorders 76<br />
weather monitoring & recording 118<br />
quality cOntrOl<br />
see ‘manufacturing & process industry’ section<br />
refrigeratiOn<br />
see ‘air conditioning & refrigeration’ section<br />
retail<br />
security & surveillance equipment 106<br />
rf & micrOWave<br />
communications test sets 21<br />
EMC test equipment 21<br />
field strength meters & antennas 19<br />
filters 26<br />
frequency counters 12<br />
logic analysers & testers 10<br />
modulation meters 20<br />
power meters 22<br />
RF amplifiers 13<br />
RF signal generators 13<br />
RF sweep generators 13<br />
spectrum analysers - high frequency 14<br />
telecommunications testing 21<br />
TV test equipment 27<br />
rOad rail & civil cOnStructiOn<br />
ac power sources/inverters<br />
/generators 68<br />
air flow measurement 113-114<br />
air quality measurement 113-114<br />
cable pipe testing & location 36<br />
concrete testing equipment 90-92<br />
dc power supplies 7<br />
distance measurement & surveying 78<br />
electrochemistry 128<br />
force measurement 84<br />
gas analysis & monitoring 123<br />
hardness testers 93<br />
inclinometers 84<br />
load measurement 85<br />
magnetic field measurement<br />
– Gauss Tesla 40<br />
noise & sound analysis 120<br />
non-destructive testing (NDT) 88<br />
power analysis & recording 40<br />
vibration & alignment analysis 88<br />
water quality testing 128<br />
weather monitoring & recording 118<br />
Security & crOWd crOntrOl<br />
bug detectors 106<br />
CCTV 106<br />
metal detectors – person<br />
& walk thru 106<br />
surveillance equipment 106<br />
thermal sensing cameras 104<br />
telecOmmunicatiOnS<br />
distortion analysers 26<br />
fibre optics testing & splicing 33<br />
frequency counters 12<br />
LAN/WAN analysis 31<br />
logic analysers & testers 10<br />
pulse generators 9<br />
RF & microwave 13<br />
RF amplifiers 13<br />
RF signal generators 13<br />
RF sweep generators 13<br />
WAN analysers 31<br />
training<br />
security & surveillance 106<br />
tranSpOrt<br />
automotive general testing 90<br />
data logging 70<br />
dc power supplies 7<br />
distance measurement 78<br />
endoscopes 79<br />
load measurement 85<br />
noise & sound analysis 120<br />
non-destructive testing (NDT) 88<br />
scales & balances 87<br />
thermal imaging cameras 104<br />
vibration & alignment analysis 88<br />
travel & leiSure<br />
metal detectors 106-107<br />
security equipment 106<br />
Water WaSteWater & plumbing<br />
data logging 70<br />
distance measurement & surveying 78<br />
electrochemistry 128<br />
endoscopes 79<br />
gas analysis & monitoring 123<br />
inclinometers 84<br />
liquid & gas flow measurement 110<br />
pipe locators 36<br />
water quality testing 128<br />
WOrkplace envirOnment<br />
air flow measurement 113-114<br />
air quality measurement 113-114<br />
data logging 70<br />
electrical insulating testing 41<br />
electrochemistry 128<br />
gas analysis & monitoring 123
ELEC<strong>TR</strong>ONICS & DATA
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
2<br />
digital StOrage OScillOScOpeS<br />
Model Channels<br />
Bandwidth<br />
(MHz)<br />
Sampling Features Interfaces<br />
TEK,TDS2014<br />
TDS,TpS2014<br />
100 1GS/s<br />
Colour, automatic measurements.<br />
Colour, battery operated, automatic & power measurements<br />
TDS2CMA,<br />
GPIB, RS232<br />
YEW,DL1540L<br />
4<br />
150 200MS/s<br />
Tektronix TDS2014 100MHz 4 Channel Colour DSO<br />
TEK,TDS2014 AU<br />
Sampling rate 1GS/s. Sensitivity 2mV~5V/div. bandwidth limited to 20MHz<br />
when set to
Tektronix TDS3054B 500MHz 4 Channel DSO<br />
TEK,TDS3054b AU/NZ<br />
Sampling rate 5GS/s. Memory length 10 k. Sensitivity 1 mV - 10 v/div. Time<br />
base 1ns~10s/div. Trigger functions include video. Extensive automatic<br />
waveform measurements. Including FFT, TV trigger, advanced analysis<br />
(TDS3AAM), and limit testing (TDS3LIM). Colour LCD with digital phosphor<br />
function. VGA, GpIb (IEEE-488) & RS232 interfaces included (TDS3GV).<br />
In-built FDD. Comes with TDS3bATb for battery operation.<br />
Tektronix THS730A 200 MHz Battery DSO<br />
TEK,THS730A AU<br />
Dual channel battery portable digital storage oscilloscope with digital<br />
multimetre facilities. Max sampling rate 1GS/s. Suited to high voltage<br />
applications depending on probe selection. Max input 640V rms, max float<br />
600Vrms. Waveform processing including watts calculations. Video trigger.<br />
RS232 interface. Use TEK,WAVESTAR software for pC interface.<br />
Tektronix Wavestar Software for TDS DSO<br />
TEK,WAVESTAR AU<br />
Acquires, prints, and exports waveforms and screen images as graphics<br />
images or data values. Exports to common packages, eg. MS Word, Excel.<br />
Obtains data via RS232, GPIB and FDD.<br />
Yokogawa DL1540L 150MHz 4 Channel DSO<br />
YEW,DL1540L AU/MY<br />
In-built printer & FDD. Amplifier bandwidth 150MHz. Sampling rate 200MS/<br />
s. Sample memory of 2Mword for 2 channels & 1Mword for 4 channels.<br />
bMp, TIF HpGL, postscript & comma separated waveform formats. GO/<br />
NOGO testing of waveforms. External sample rate input - useful for rotating<br />
machinery work. Waveform computations including FFT. Averaging function<br />
to reduce the S/N ratio, accumulate function. GpIb interface.<br />
Fluke 196 100MHz 2 Channel Portable Scopemeter<br />
FLU,196 NZ<br />
Real-time sampling 1GS/s per input. Connect & view automatic triggering,<br />
a full range of manual trigger modes plus external triggering. 27,500 points<br />
per input record length using Scoperecord mode. Automatic capture and<br />
replay of 100 screens. Automatic waveform measurements 24. Cursors,<br />
zoom and real-time clock. 1kV independently floating isolated inputs.<br />
Includes a 5000 count true-rms multimeter and a Trendplot paperless<br />
recorder.<br />
Tektronix 2205GM 40MHz Dual Trace Oscilloscope<br />
TEK,2205GM AU<br />
Vertical sensitivity 5mV/div~5V/div. Timebase 0.1µs~0.5sec/div x10<br />
magnifier. TV line and field trigger.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
digital StOrage OScillOScOpeS<br />
Fluke 199C Scopemeter 200MHz Hand-held<br />
FLU,199C-SCOpEMETER AU<br />
FLU,199 NZ<br />
Colour digital oscilloscope, 200MHz bandwidth, 2 channel with DMM<br />
feature. Colour display 14.4cm with persistence feature. Real time sampling<br />
2.5GS/s. Input sensitivity 5mV/div~100V/div. Glitch capture 3ns using pulse<br />
width triggering. Timebase range in scope mode 5ns/div~2min/div. Trigger<br />
types auto, free run, single shot, edge, delay, video, video line, selectable<br />
pulse width & external. Automatic capture and replay of last 100 screens.<br />
Measures electrical power properties such as VA, VAR, etc. Inputs are<br />
isolated (1kV CAT II/600V CAT III). pC software. battery operation 4h.<br />
HP/Agilent MSO6104A 1GHz Digital Oscilloscope with Logic<br />
Hp,6104A AU<br />
Agilent 6104A 1 GHz 4 + 16 channel mixed signal oscilloscope (MSO).<br />
4Gsa/s. xGA Colour display updates 100,000 waveforms/sec with 256 levels<br />
intensity. 4 analogue channels and 16 logic channels. Deep memory. 8 digit<br />
frequency counter function. Triggering includes video, HDTV, I2C, SPI, LIN,<br />
CAN, and USb. FFT analysis included. LAN, USb, GpIb, & xGA interfaces<br />
standard.<br />
nOn-StOrage OScillOScOpeS<br />
Tektronix 300MHz Portable Oscilloscope 4 Channel<br />
TEK,2465 AU<br />
2mV~5V/div. Dual timebase with delayed sweep, 500ps~0.5s/div. 50Ω &<br />
1mΩ input impedance.<br />
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 3
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
4<br />
prObeS and acceSSOrieS<br />
Model Type Bandwidth Attenuation Voltage Max Current Max (A)<br />
FLU,80K-40<br />
DC~100MHz 1:1,000 40kV dc, 28kV ac<br />
MET,HT212-30KDC DC 1:100 30kV dc<br />
TEK,P6015 Voltage high<br />
75MHz 1:1,000 40kV<br />
COL,HV40b dc to 300Hz 1,000:1<br />
ACR,SI9000 Voltage isolation 15MHz 1:20, 1:200 700V<br />
bEL,CG-100A Current clamp-on AC DC dc~1kHz 660 rms 100<br />
TEK,p6302-CT5 Current clamp-on 20 MHz 50K<br />
TEK,P6158 Passive probe 30GHz 1:20<br />
TEK,5200 Differential probe dc to 25MHz 1300V<br />
See also Electrical Transducers<br />
Agilent 82357A GPIB/HPIB/IEEE488 to USB interface<br />
Hp,82357A AU<br />
Allows all GpIb/HpIb/IEEE488 equipment to controlled from any USb<br />
equipped pC (not MACs). Drivers for pC. Separate software may be<br />
required for equipment being controlled.<br />
Fluke 80K-40 High Voltage Probe<br />
FLU,80K-40 AU<br />
1~40kV dc or peak ac, 28kV ac rms. Input resistance 1GΩ, division ratio<br />
1,000:1. Note: input impedance of DVM must be 10MΩ or reading will be<br />
wrong.<br />
Acree SI9000 Differential Probe<br />
ACR,SI9000 AU<br />
Input probe for converting oscilloscopes, etc, to floating input for power<br />
measurements, etc. Input attenuation 1/20 & 1/200 with 2MΩ impedance to<br />
earth. bandwidth dc~15MHz. Max input 700Vac. Input range up to 700Vdc<br />
in 1/200 mode. battery operated.<br />
Bell CG-100 A Clip-on Current Gun<br />
bEL,CG-100A AU<br />
Current range dc, ac 10A~100A. DC~1kHz, accuracy 2%, 100% overrange<br />
capacity, clamp ¾“Ø, 30h battery operation, IV output for oscilloscope.<br />
National Instruments GPIB-USB Interface with Plotter Software<br />
NAT,GpIb-USb-HS AU<br />
High speed GpIb to USb interface. provides control of GpIb/HpIb/IEEE488<br />
devices from a USb equipped pC (requires Win 2000 or later operating<br />
system). Includes software to allow PC to emulate a GPIB plotter. Plotter<br />
software outputs plots as HpGL, HpGL/2, JpEG, TIFF, bMp & WMF. plotter<br />
software can emulate Hp 7440, Hp 7470, Hp 7475, Hp 7550 & Hp 7570<br />
pen-plotters.<br />
Tektronix P5200 Isolated Differential Probe<br />
TEK,P5200 NZ<br />
High voltage differential probe to provide a safe means of measuring circuits<br />
with floating potentials up to 1kV from earth to ground and up to 1,300V<br />
differential. Range settings are 1/50 & 1/500. bandwidth: dc to 25MHz<br />
accuracy is ±3%, input impedance is 8MΩ, 3.5 pF between inputs. Rise<br />
time is 14ns.<br />
Tektronix P6158 Passive RF Probe dc 3GHz 20X<br />
TEK,p6158 AU<br />
Attenuation dc~3GHz 20x. Input resistance 1kΩ.<br />
Tektronix P6015 40kV High Voltage Probe<br />
TEK,p6015 AU<br />
bandwidth 75MHz. Input rating: 40kV pulse, 20kVdc plus peak ac. Derating<br />
with frequency applies. Input impedance 100MΩ. Attenuation x 1000.<br />
USB to RS232 Converter<br />
USb,232CONVERTER AU<br />
Stackable expansion module that connects to a pC or server via the USb<br />
port. provides 1 high speed RS-232 serial port. System Requirements;<br />
pentium class, USb type A, Win 98, ME, 2000, xp, MAC 8.6 & later.
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
multimeterS and electrOmeterS<br />
Model Type Application Scale (digit) Interface True RMS Max (V)<br />
FLU,177<br />
FLU,189<br />
HIO,3256-50 Digital HiTester multimeter General 6 No 1,000<br />
HIO,3805<br />
MET,Mx44<br />
Multi Function Digital<br />
Multimeter<br />
MET,Mx53<br />
General<br />
MET,Mx54<br />
Multimeter<br />
MET,Mx51Ex Intrinsically safe<br />
FLU,87<br />
FLU,87-2<br />
4½ 1,000<br />
Hp,3400A RMS voltmeter Audio/RF Analogue Analogue output 300<br />
FLU,8010A<br />
LEM,UNIGOR355 4¾<br />
General<br />
LEM,UNIGOR380 Multimeter<br />
6<br />
3½<br />
Yes<br />
IR interface Yes<br />
Hp,34401A<br />
RS232/HpIb<br />
6½<br />
Hp,3455A-NATA Precision HPIB Yes<br />
GOS,ME<strong>TR</strong>AHIT-29S<br />
powermeter - <strong>TR</strong>MS<br />
Multimeter<br />
1,000<br />
Precision ±310,000 count IR interface Yes CAT III 600<br />
SIM,SS2x Charge measurement Electrostatic Analogue 200 kV/m<br />
MMM,709 Electrostatic meter Static voltage 4 No 8,000<br />
> NEW<br />
Fluke 87-2 Digital Insulation Multimeter<br />
FLU,87-2 MY<br />
A combined digital insulation tester with a full-featured, true RMS digital<br />
multimeter in a single, compact, handheld unit, which provides maximum<br />
versatility for both troubleshooting and preventative maintenance.<br />
> NEW<br />
Fluke MultiMeter with Backlight<br />
FLU,177 AU<br />
General purpose multimeter. True RMS voltage and current measurements,<br />
digital display with analog bargraph and backlight, manual and automatic<br />
ranging, display Hold and Auto Hold, frequency and capacitance<br />
measurements. Overvoltage category EN61010-1 CAT III 1000V/CAT IV<br />
600V.<br />
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 5
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
6<br />
multimeterS and electrOmeterS<br />
> NEW<br />
Fluke Logging Multimeter<br />
FLU,189 AU<br />
Higher end multimeter. PC interface for data exchange, internal memory<br />
allows stand-alone logging of up to 1000 measurements. Extremely fast<br />
readings true RMS AC + DC measurements, 100kHz ac bandwidth for<br />
voltage and current, dual display with bargraph and two-level backlight, min/<br />
max/average with real time clock and 250µs Fast Min-Max, Temperature<br />
measurement -200ºC~1350ºC, dbV/dbm with selectable reference.<br />
Overvoltage category EN 61010-1 (IEC 1010-1) CAT III 1000V/CAT IV<br />
600V.<br />
> NEW<br />
Hioki 3805 Multi Function Handy Type Digital Multimeter<br />
HIO,3805 AU<br />
9999 count display full scale for voltage range. Optional RS232C package<br />
for transferring data to a PC, True rms rectified, easy harmonic distortion<br />
check function, simultaneous 2-point temperature measurement, maximum,<br />
minimum, average value display, 4~20mA measurement value convert to<br />
0-100 % display, for maintaining and serving industrial meter. Meets CAT III<br />
600V requirements and CAT II 1kV requirements.<br />
Gossen Metra Hit 29S Powermeter - <strong>TR</strong>MS Multimeter<br />
GOS,ME<strong>TR</strong>AHIT-29S AU<br />
High Precision Digital Multimeter<br />
Hioki 3256-50 Digital Multimeter CAT II 1kV & CAT III 600V<br />
HIO,3256-50 AU<br />
Hioki 3256-50 Digital HiTester Multimeter, CAT II 1000V and CATIII 600V<br />
AC/DC, Current 10A AC/DC.<br />
Metrix MX54 Digital Multimeter<br />
MET,Mx54 AU<br />
Measures ac/dc voltage and current, resistance, frequency, and capacitance.<br />
4½ digit display giving a sensitivity of 10µV & 10nA. Ranges: voltage<br />
500mV~1,000V (750V ac), current 500µA~10A, resistance 500Ω~50MΩ<br />
with a max resolution of 10mΩ, frequency; 0.6Hz ~500kHz; db measurement<br />
over impedance range 1~9,999Ω.<br />
Metrix MX55 <strong>TR</strong>MS Multimeter<br />
MET,Mx55 MY<br />
True rms digital multimeter measuring ac/dc voltage & current, resistance,<br />
frequency. 4.5 digit display.<br />
Metrix MX51EX Intrinsically Safe Digital Multimeter<br />
MET,Mx51Ex AU<br />
Resolution 5,000 count with 0.1% basic accuracy. Measures ac/dc voltage<br />
and current, and resistance. Voltage sensitivity 100µV. Max voltage 1kV dc,<br />
750Vac. Max current 10A. Intrinsic safety limits of 60V & 500mA.<br />
Metrix MX53 Hand Held Digital Multimeter<br />
MET,Mx53 AU<br />
Display 50,000 count with 34 segment bar graph. Vdc range 500mV~1kV.<br />
Vac range 500mV~750V. Current range 500µA~10A. Resistance<br />
range 500Ω~50MΩ. Capacitance range 50nF, 50mF. Frequency range<br />
0.6Hz~500kHz. Min & max value mode. Continuity and diode checking<br />
functions.<br />
HP 3400A ac True rms 10MHz Analogue Voltmeter<br />
Hp,3400A AU<br />
Analogue display 10Hz~10MHz, 1mV~300V FS. Recorder output.<br />
Fluke 87 Digital Multimeter<br />
FLU,87 NZ<br />
Handheld digital multimeter. Measures ac/dc voltage, current and resistance.<br />
peak hold feature.<br />
LEM Unigor 355 Hand-held Digital Multimeter/Signal Generator<br />
LEM,UNIGOR355 AU<br />
Measures dc, ac trms voltage & current, resistance, frequency, capacitance,<br />
temperature & time. Display 4¾ digit. Resolution 10µV, 10nA, 10mΩ, 1pF<br />
& 0.01Hz. Ranges voltage 300mV~1kV, current 300µA~10A, resistance<br />
300Ω~30MΩ, frequency 300Hz~100kHz, db -48~63, temperature ºC/ºF, pt<br />
100 -200~100ºC, pt 1000 100~850ºC. Features automatic socket shutters,<br />
IR interface, split second chronograph, automatic measurement value<br />
storage, etc.<br />
LEM Unigor 380 Digital Multimeter<br />
LEM,UNIGOR380 AU<br />
Precision 6 digit multimeter. Measures dc, ac trms voltage & current,<br />
resistance, frequency, capacitance, temperature & time. Resolution<br />
1µV, 1nA, 1mΩ, 1pF & 0.001Hz. Ranges voltage 300mV~1kV, current<br />
300µA~10A, resistance 300Ω~30MΩ, frequency 300Hz~300kHz, db -<br />
48~63, temperature ºC/ºF K -200~1,372ºC, J -210~1200ºC. Features<br />
automatic socket shutters, IR interface, split second chronograph, automatic<br />
measurement value storage, etc.<br />
HP 34401A Digital Multimeter<br />
Hp,34401A AU<br />
precision 6½ digit multimeter. 100nV sensitivity on dc 120mV range. Max dc<br />
input 1kV. Measures ac voltage, dc & ac current to 3A, 2 or 4 wire resistance<br />
to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths functions<br />
including limits test. 512 point storage. RS232 and HPIB interfaces.<br />
Keithley 2503 Static Detector Probe<br />
KEI,2503 AU<br />
Detects voltage due to charge on small surface areas. Used at a distance of<br />
6mm from a surface having a charged plane of at least 13mmØ.<br />
Simco SS2X Electrostatic Charge Meter (Analogue)<br />
SIM,SS2x AU<br />
Designed for detecting and measuring the voltage and field strength<br />
associated with static charges on objects and materials. Capable of<br />
measuring voltages from 0 ~200 KV and field strength from 0~4000MV/M<br />
3M 709 Electrostatic Meter<br />
MMM,709 NZ<br />
Digital electrostatic meter. Reads 20kV at 25mm distance, accuracy ±10%.<br />
2 volt recorder output.
Model Current Max (A) Voltage (Vdc) Dual Variable<br />
Hp,E3640A 3, 1.5 8, 20<br />
Yes<br />
LAb,622 2<br />
30<br />
RED-30V-30A 30 No<br />
bWD,246A 5 36 Yes<br />
<strong>TR</strong>I,pD35-20 20 35<br />
SOR,DCR10-120b 120 10<br />
SOR,DCR600-3b 3 600<br />
SOR,DCS60-50<br />
AUS,AD2K5<br />
INV,MpS48DC2400W<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
50<br />
<strong>TR</strong>I,pD35-10D 10 35<br />
xAN,xKW60-50 50 60<br />
BWD 246A Dual Power Supply<br />
bWD,246A AU<br />
Dual output 0~36V, 0~5A per section. Use in series, parallel or tracking<br />
modes.<br />
Trio PD35-20 DC Power Supply<br />
<strong>TR</strong>I,pD35-20 AU<br />
Output 0~35V, 0~20A. Constant current, constant voltage. Multiple parallel<br />
or series operation. Remote programming of voltage or current by external<br />
voltage or resistance.<br />
Ausmode AD2K5 48V 50A Rectifier<br />
AUS,AD2K5 AU<br />
DC rectifier (power supply), 50A @ 48V. Voltage not adjustable. Use to<br />
power telecoms and other battery supported equipment.<br />
Agilent E3640A Programmable DC Power Supply<br />
Hp,E3640A AU<br />
30W single-output programmable power supply with built-in GpIb and RS232<br />
connectivity and SCpI language compatibility. 0~8V/3A or 0~20V/1.5A.<br />
Over-voltage protection and remote sensing. Low noise and excellent<br />
regulation. Front and rear output terminals.<br />
Lab 622 Dual 0~30Vdc DC Power Supply<br />
LAb,622 NZ<br />
Adjustable current limit of 0~2A dc.<br />
Redfern 30V / 30A Power Supply<br />
RED,30V-30A NZ<br />
Adjustable current trip from 0~30V. Voltage and current meters.<br />
Sorensen DCR10-120B dc Power Supply<br />
SOR,DCR10-120b AU/MY<br />
0~10V, 0~120A.<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
60<br />
48<br />
dc pOWer SupplieS<br />
Sorensen DCR600-3B dc Power Supply<br />
SOR,DCR600-3b AU<br />
0~600V, 0~3A.<br />
Sorensen DCS60-50, 60V 50A dc Power Supply<br />
SOR,DCS60-50 AU<br />
0~60V, 0~50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph<br />
240V supply. On 1ph 50V @ 50A or 60V @ 42A. Remote programming.<br />
Trio Kenwood PD35-10D 35V 10A Power Supply<br />
<strong>TR</strong>I,pD35-10D AU<br />
Output 0~35V, 0~10A. Constant current, constant voltage. Multiple parallel<br />
or series operation. Remote programming of voltage or current by external<br />
voltage or resistance.<br />
Invensys Intergy Mini Power System 48V dc 2.4kW Supply<br />
INV,MpS48DC2400W AU<br />
Sub-rack Mini System 19” rack mount range. Ideal solution for low power<br />
telecommunications applications (premises Data Networks and Ip Routers,<br />
Local Loop Transmission Systems and Wireless) requiring compact, efficient<br />
and flexible dc power supplies. Includes an integral dc distribution panel<br />
and an SM30 Series Intergy Supervisory Module. All system settings are<br />
fully adjustable in software. Input: R1148: 220/240Vac, 50/60Hz (nominal).<br />
power factor: >0.98 @ 30~100% max system current. Efficiency: >89%.<br />
Output; voltage 48V, 45~60Vdc, current @ 48Vdc 50A (2400W). Dimensions:<br />
133H x 275W mm overall. Weight: 12kg typical configuration.<br />
Xantrek XKW60-50 60V 50A dc Power Supply<br />
xAN,xKW60-50 AU<br />
0~60V, 0~50A. Constant current and constant voltage. Analogue<br />
programming. Operation of multiple units in series or parallel.<br />
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 7<br />
No<br />
Yes<br />
No<br />
Yes
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
8<br />
functiOn generatOrS<br />
Model Special features Frequency Max (MHz) Frequency Min (µHz) Voltage Max Arbitary<br />
HP,3325B High stability & accuracy 21 MHz 1<br />
Hp,33120A 15 MHz 100<br />
Hp,33220A 20MHz<br />
Hp,33250A 80 MHz<br />
> NEW<br />
Tektronix 3022/25MHz Arbitrary Function Generator<br />
TEK,AFG3022 AU<br />
Dual channel function/arbitrary waveform generator. Frequency range<br />
1mHz ~25MHz sine, 12.5MHz square & pulse waveforms, 250 kHz triangle,<br />
ramp, noise & DC waveforms. Arbitrary waveform generation 12.5MHz.<br />
Gaussian noise to 25MHz. Output into 50Ω 10mV~10V p-p. AM, FM, FSK,<br />
and burst modulation. HpIb, USb, & LAN interfaces used with included<br />
software allows waveforms to be created on PC and imported into unit. Full<br />
screen display also allows display and editing of waveforms on unit itself.<br />
> NEW<br />
Tektronix 3102/100MHz Arbitrary Function Generator<br />
TEK,AFG3102 AU<br />
Dual channel function/arbitrary waveform generator. Frequency range<br />
1mHz~100MHz sine, 12.5MHz square and pulse waveforms, and 250kHz<br />
triangle, ramp, noise, and DC waveforms. 12.5MHz Arbitrary waveform<br />
generation. Gaussian noise to 25MHz. Output into 50ohms 10mV~10V p-p.<br />
AM, FM, FSK, and burst modulation. HpIb, USb, and LAN interfaces used<br />
with included software allows waveforms to be created on PC and imported<br />
into unit. Full screen display also allows display and editing of waveforms<br />
on unit itself.<br />
Agilent 33220A 20MHz Function/Arbitrary Generator<br />
Hp,33220A AU<br />
Function/arbitrary waveform generator. Frequency range 20MHz sine &<br />
square waveforms, 200kHz pulse, triangle, ramp, noise, and DC waveforms.<br />
Gaussian noise to 10MHz. Output into 50Ω 10mV~10V p-p. AM, FM, FSK,<br />
and burst modulation. Includes option 001 external timebase reference.<br />
With optional benchlink software waveforms can be captured and played<br />
back. HpIb, USb, & LAN interfaces.<br />
1<br />
10Vp-p Yes<br />
HP 33120A Function/Arbitrary Generator<br />
Hp,33120A AU/MY<br />
Frequency range 15MHz sine & square waveforms, and 100kHz triangle &<br />
ramp waveforms. Gaussian noise to 10MHz. Output into 50, 50mV~10V pp.<br />
AM, FM, FSK, and burst modulation. Optional benchlink software allows<br />
waveforms to be captured and played back. HpIb & RS232C interfaces.<br />
Some assets include option 001 phase lock and high stability TCxO timebase<br />
- input & output 10MHz with phase offset.<br />
HP 33250B Synthesized Function Generator<br />
Hp,3325b AU<br />
Sine frequency range 1µHz~21MHz, square wave/triangle/ramps to 11MHz.<br />
Sweep generator function. In-built modulation generator which includes<br />
arbitrary waveforms with arbitrary, sine, and square wave outputs. Output<br />
phase can varied with 0.1O resolution and multiple units can be locked<br />
together for variable phase output signals. Very high amplitude resolution<br />
and setting accuracy.<br />
HP/Agilent 33250A 80MHz Function/Arbitrary Waveform<br />
Generator<br />
Hp,33250A AU<br />
Frequency range 80MHz sine & square waveforms. 50MHz pulse waveforms<br />
with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz triangle &<br />
ramp waveforms. White noise to 50MHz. Output into 50Ω 10mVpp~10Vpp.<br />
AM, FM, FSK, and burst modulation. Intuilink software for programming<br />
arbitrary waveforms. HPIB & RS232C interfaces.
HP 8012B Pulse Generator<br />
Hp,8012b AU<br />
pulse generator 1Hz~50MHz. Variable transition times down to 5ns. Amplitude +10V with selectable source impedance. pulse width 10ns~1s. External<br />
trigger and gate.<br />
Stanford Research SR1720 LCR Bridge<br />
SR,SR720 AU<br />
Automatic LCR bridge with 0.05% accuracy. Ranges: inductance<br />
0.0001µH~99,999H; capacitance 0.0001pF~99,999µF; resistance<br />
0.0001Ω~2,000MΩ. Also measures Q & D. Test frequencies 100/120Hz,<br />
1/10/100kHz. Indicates value, deviation, % deviation, or bin number. DC<br />
bias internal 0~2V, external 0~40V. Complete with optional Kelvin leads.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
pulSe generatOrS<br />
lcr meterS<br />
Tegam 3550 45Hz-5MHz Programmable LCR Meter<br />
TEG,3550 AU<br />
programmable Impedance/LCR Meter. User selectable test frequency from<br />
42.0Hz~5.00MHz. 18mS measurement speed. 0.10% basic accuracy. Fully<br />
programmable with18 measurable parameters and absolute or percentage<br />
comparator. Binning function supports 10 output bins. Output to 3 highly<br />
visible LED displays. Standard RS232C & I/O interfaces<br />
Model Type Description Accuracy %<br />
DAN,DR60 Resistance box Decade resistance box<br />
GR,1433-20 Resistance Box Decade resistance box<br />
GR,1433b-NATA Resistance box 1~11.1MΩ Decade resistance box. 6 decades x 1Ω<br />
> NEW<br />
Genrad 1433-20 Decade Resistor<br />
GR,1433-20 MY<br />
Resistance range from 1mΩ~111MΩ. High accuracy 0.01% up to<br />
10MΩ steps. Low temperature coefficient, 5 ppm/°C. Good frequency<br />
characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero<br />
resistance (
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
10<br />
lOgic/analySerS/teSterS<br />
> NEW<br />
Protek 3290 RF Analyser/Signal Meter 2.9GHz<br />
pRO,3290 AU<br />
RF signal analyser and level meter. Provides spectrum display up to 2.9<br />
GHz, audio output, level measurement, and frequency measurement. Inbuilt<br />
antenna. Frequency range 100 kHz to 2.9GHz with frequency steps from<br />
5 kHz. Modulation types narrow and wide band FM, AM, and SSb. Level<br />
measurement minimum frequency - narrow band FM 1 MHz, wide band FM,<br />
AM, SSb 10 MHz. bandwidth - narrow band FM 12.5 kHz, wide band FM<br />
180 kHz, AM & SSb 2.4 kHz. Input impedance 50 ohms.<br />
HP 1662A 68 Channel Logic Analyser<br />
Hp,1662A AU/MY<br />
Timing analysis 250MHz all channels, 500MHz half channels. Transitional:<br />
125MHz all channels, 250MHz half channels. Glitch: 125MHz half channels.<br />
State analysis to 100MHz on all channels. Memory 4k/channel, 8k/channel<br />
in half-channel modes. 4 clock channels available. HpIb & RS232C ports.<br />
In-built DOS format FDD used to load inverse assemblers and transfer<br />
measurement data to a computer. Compatible with most HP preprocessors<br />
and inverse assemblers.<br />
prOm prOgrammerS<br />
IceTech LV48 Programmer<br />
ICE,LV48 AU<br />
Eprom programmer for single device with laptop and preloaded software.<br />
programs devices up to 48 pins.<br />
Data IO Chipwriter Standard<br />
DAT,CHIpWRITER AU<br />
Eprom programmer for single device with laptop and preloaded software.<br />
programs devices up to 40 pins.<br />
Data IO Chipwriter Gang 8 Chip<br />
DAT,CHIp-GANG AU<br />
Eprom programmer for 8 devices. Eight copy sockets and one master socket.<br />
Can be used with a PC or in stand alone mode (two button operation).<br />
Programs devices up to 32 pin DIP.<br />
frequency reSpOnSe analySerS<br />
HP35660A 100kHz Dual Channel Spectrum Analyser<br />
Hp,35660A AU/MY<br />
Displays frequency response, power spectrum, linear spectrum, coherence,<br />
cross spectrum, power spectral density, and time. 401 line resolution. Signal<br />
sources: fixed sine, random noise, chirp. built-in disk drive. HpIb interface.<br />
bandwidth is 102.4kHz for single channel measurements and 51.2kHz for<br />
dual channel measurements.<br />
> NEW<br />
Agilent/HP 1652B 80 Channel Logic Analyser<br />
Hp,1652b AU<br />
80 channels, maximum conventional timing rate 100 MHz, transitional<br />
timing rate 100MHz & glitch timing rate 50MHz. Memory depth/channelnormal<br />
1Kb. Channel to channel delay 4ns. Minimum recognizable glitch<br />
width 5ns. Setup/hold time 10ns. 2 scope channels. bandwidth 100MHz.<br />
Simultaneous maximum sampling rate/Ch - 400 MSa/s. HpIb,RS232C.<br />
FDD.<br />
Agilent 16500C Logic Analyser<br />
Hp,16500C AU<br />
Mainframe with 16555D acquisition card and 16522A pattern generator<br />
module. 110MHz 68 channels. Memory depth 2M (4M in half channel<br />
timing mode). Minimum detectable glitch 3.5ns. Advanced trigger macros<br />
for capturing elusive problems.<br />
Hi-Lo All 11 Programmer<br />
ALL,11 AU<br />
programmer for byte wide EpROM, EEpROM and flash pROM with 24~32<br />
pins. Enables programming or copying of up to 8 devices at a time. Adaptors<br />
provided to convert standard dip arrangement to pLCC for programming/<br />
copying of single (one only) pLCC packages. Unit will handle devices up to<br />
8Mb. i.e. 27C010~27C080.<br />
Spectronics Ultra Violet PROM Eraser<br />
SpE,ERASER2 AU<br />
Holds up to 8 devices. 0~60min timer, 240V/50Hz operation.<br />
> NEW<br />
HP35670A 100kHz Spectrum Analyser<br />
Hp,35670A AU<br />
Quad channel 100 khz spectrum analyser. Up to 1600 line resolution.<br />
Displays frequency response, power spectrum, linear spectrum, coherence,<br />
cross spectrum, power spectral density, and time. Signal sources: Fixed &<br />
Swept sine, Arbitrary Waveform, Random noise, Chirp. built-in disk drive.<br />
HpIb plotter interface. bandwidth is 102.4, 51.2 and 25.6KHz for single,<br />
dual and quad channel measurements respectively.
Performance on-the-move<br />
Strength in the palm of your hand<br />
New U1250A series handheld DMMs place<br />
versatility at your fingertips!<br />
• 50,000 count resolution, dual displays<br />
• Unlimited data logging from DMM to PC<br />
• Programmable square wave generator<br />
• Temperature, Capacitance, Maths functions<br />
• 20MHz frequency counter<br />
New U1600A series handheld scopes bring high<br />
performance on the move!<br />
• Scope-DMM-Recorder - all-in-one<br />
• 4.5-inch LCD colour display<br />
• FFT, Zoom and Math functions<br />
• 200MSa/s sampling rate<br />
• 125kB/ch memory depth<br />
Australia 1300 726 550<br />
(Measurement Innovation - Australia wide)<br />
New Zealand 0800 738 378<br />
www.agilent.com/find/U1250A<br />
www.agilent.com/find/U1600A<br />
Say hello to the next generation of Agilent Technologies;<br />
the new handheld digital multimeters and oscilloscopes<br />
that are built to test and designed to save.<br />
Featuring built-in battery charging capability, exciting<br />
and innovative new features and over-mould casing for<br />
protection in the toughest conditions.<br />
If you need a test instrument that offers the ultimate<br />
portable test capabilities, Agilent’s range of handheld<br />
digital multimeters and oscilloscopes are the right choice.<br />
Redefining Feature-Rich Portability with<br />
the New Handheld Series<br />
View an online demo:<br />
www.agilent.com/find/U1250A_showcase<br />
www.agilent.com/find/U1600A_showcase
GENERAL ELEC<strong>TR</strong>ONIC TEST EQUIPMENT<br />
12<br />
frequency cOunterS<br />
Model Type Frequency (GHz)<br />
RAC,9906 Universal frequency counter dc~0.200<br />
SIC,WL260-pC230 Optical timing sensor<br />
PHI,PM6666<br />
Hp,5350A<br />
Universal frequency counter<br />
Hp,53181A dc~3<br />
HP,5352B Automatic microwave counter 10Hz~20GHz<br />
Hp,5385A Universal frequency counter, DC operation dc~1GHz<br />
ADV,<strong>TR</strong>5212 Universal frequency counter 10MHz~18GHz<br />
Racal 9906 Frequency Counter/Timer<br />
RAC,9906 AU<br />
Counter/timer 200MHz. Eight digit display. Measures frequency, period,<br />
totalise, time interval and ratio. Input impedance 1MΩ. Input sensitivity<br />
10mV.<br />
Sick WL260-P230 Reflex Photoelectric Switch<br />
SIC,WL260-p230 AU<br />
Light and sensor in the same unit. Detects reflection from reflector mounted<br />
on or behind the object to be detected. Range 0.01~5m. Output compatible<br />
with Racal 9906 counter. Mains operated. Supplied 50 x 50mm reflector.<br />
Does not work with normal mirror, white card etc, detects interruptions using<br />
supplied mirror.<br />
Philips PM6666 1.1GHz Universal Counter<br />
pHI,pM6666 AU<br />
Frequency, period, time interval, totalise, and ratio measurements. GPIB<br />
interface. High stability MTCxO timebase option fitted.<br />
dc~1<br />
HP 53181A 3GHz Frequency Counter<br />
Hp,53181A AU/MY<br />
Option 010 high stability timebase included. HPIB interface. PC based<br />
benchlink meter software available.<br />
HP 5350A 20GHz Frequency Counter<br />
Hp,5350A MY<br />
Automatic Microwave Counter. Input 1: 500MHz~20.0GHz 50Ω input<br />
impedance. Input 2 10Hz~525MHz at 50Ω. 10Hz~80MHz at 1 MΩ. HpIb<br />
interface standard. Option 006 input damage protection included.<br />
HP 5352B 40GHz Frequency Counter<br />
Hp,5352b AU<br />
Automatic microwave counter. Input 1 500MHz~40GHz. Input 2<br />
10Hz~525MHz. Sensitivity at 40GHz to 20dbm. TCxO timebase with aging<br />
rate 1 part in 10 million per month. HpIb interface. Input connector ApC-3.5<br />
(male) with collar; type N adaptor included.<br />
HP 5385A 1GHz Frequency Counter<br />
Hp,5385A AU<br />
Eleven digit display. Also measures period up to 0.1s. TCxO timebase.<br />
Operates from ac or 9~15Vdc. HpIb interface.
HP E4432B ESG-D3000A 3GHz RF Digital Signal Generator<br />
Hp,ESG-D3000A MY<br />
RF signal generator with digital modulation facilities. Frequency range<br />
250kHz~3GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation.<br />
Wideband AM modulation. DC to 10MHz. Internal modulation and pulse<br />
generator to 50kHz. Step sweep of frequency and power. Included option<br />
UN3 provides DECT, GSM, NADC, pDC, pHS, & TE<strong>TR</strong>A standards. External<br />
analogue I & Q modulation inputs. Option 1E5 high stability reference<br />
0.1ppm/yr included.<br />
HP E4433B ESG-D4000A 4GHz RF Digital Signal Generator<br />
Hp,ESG-D4000A AU<br />
Signal generator with digital modulation facilities. Frequency range<br />
250kHz~4GHz, resolution 0.01Hz. AM, FM, phase, & pulse modulation.<br />
Wideband AM modulation. DC to 10MHz. Internal modulation and pulse<br />
generator to 50kHz. Step sweep of frequency and power. Option 1E5 high<br />
stability reference 0.1ppm/yr included.<br />
HP 8648B 2GHz Signal Generator (Analogue)<br />
Hp,8648b AU/MY<br />
Frequency range 9kHz~2GMHz. Output range 13dbm~-136dbm, 1db<br />
accuracy over entire frequency range, resolution 0.001Hz. Full remote<br />
control via GpIb (IEEE488) interface.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
rf Signal generatOrS<br />
Model Type (All programmable) Frequency Output<br />
Hp,ESG-3000A AM/FM microwave signal generator 250kHz~3GHz<br />
Hp,ESG-D4000A AM/FM high stability microwave signal generator 250kHz~4GHz<br />
Hp,8648b High stability signal generator 9kHz~2GHz 13dbm~-136dbm<br />
Hp,8648C<br />
9kHz~3.2GHz<br />
AM/FM high stability signal generator<br />
Hp,8648D 9kHz~4GHz<br />
10dbm~-136dbm<br />
FLU,6060b AM/FM high stability signal generator 10kHz~1,050MHz -127dbm~13dbm<br />
HP 8350B Sweeper Mainframe<br />
Hp,8350b AU/MY<br />
Operates directly with Hp,8757A scalar network analyser and Hp,7475A<br />
plotter or Hp,2225A printer.<br />
HP 83525B 10MHz~8.4GHz Sweep Module<br />
Hp,83525b AU<br />
Sweep generator module for Hp,8350b. Frequency range 10MHz~8.4GHz.<br />
HP 83594A Module for 8350B 2 to 26.5GHz<br />
Hp,83594A AU<br />
broadband sweeper plug-in for Hp,8350b mainframe. Frequency range<br />
2~26.5GHz. Max levelled output 10mW up to 20GHz, 2.5mW up to<br />
26.5GHz.<br />
HP 8648C-1E5 3GHz Signal Generator<br />
Hp,8648C AU/MY<br />
Signal generator 9kHz~3.2GHz with AM/FM/phase modulation output range<br />
from +10~-136 dbm with ±1 accuracy up to 2.5GHz. 0.001Hz resolution.<br />
Complete with option 1E5 high stability timebase (
RF & MICROWAVE<br />
14<br />
Spectrum analySerS - high frequency<br />
Model Type Frequency Resolution (Hz)<br />
HP,8591E<br />
Hp,8594E<br />
Spectrum analyser<br />
Hp,8594E-G Spectrum analyser with tracking generator<br />
9MHz~1.8GHz<br />
9kHz~2.9GHz<br />
ADV,R3365A Spectrum analyser with tracking generator 100kHz~8GHz 10<br />
Hp,E4407b<br />
HP,8591 Spectrum analyser<br />
9kHz~1.8GHz 1kHz<br />
1kHz<br />
9kHz~26.5GHz 30<br />
HP,8593E 9kHz~22GHz 30<br />
HP,8563E Spectrum analyser, high resolution 9kHz~26.5GHz 1<br />
AIR,AIRMAG SpEC AN Spectrum analyser<br />
ANR,MS2711A Portable spectrum analyser<br />
ANR,MS2711D Spectrum analyser, colour, portable<br />
2.5~2.5GHz<br />
4.9~5.9GHz<br />
9kHz~3GHz<br />
ANR,MS2711D-6-29 Spectrum analyser with power meter 9kHz~6GHz<br />
ANR,S332b<br />
10<br />
Network analyser with spectrum analyser 9kHz~3GHz<br />
ANR,S332D 100<br />
ANR,S332D-29 Network analyser with spectrum analyser with colour screen 10<br />
RS,FSH3-TG Spectrum analyser with tracking generator and return loss bridge 100kHz~3GHz<br />
RS,FSH3-TG-V Spectrum analyser with tracking generator and vector measurements 100kHz~3GHz<br />
RS,FSH6-TG<br />
100kHz~6GHz<br />
Portable spectrum analyser<br />
ADV,U3771 9kHz~31.8GHz 100<br />
www.rohde-schwarz.com.au<br />
sales@rohde-schwarz.com<br />
Gear up for your next adventure<br />
The R&S®FSH - for on-site RF measurements<br />
Where is your next adventure in RF measurements taking you? To install a base station on the African savanna?<br />
To perform distance-to-fault measurements on the International Space Station? Then you need a flexible and robust<br />
do-it-all solution - the R&S®FSH Handheld Spectrum Analyser. It’s an entire test lab that fits in one hand: spectrum<br />
analyser, vector network analyser, high-precision power meter, test receiver, EMI/EMCE analyser and much more.<br />
It also features a wide selection of accessories.<br />
10kHz<br />
100<br />
1kHz
Rohde & Schwarz FSH3 Spectrum Analyser/Tracking Generator<br />
RS,FSH3-TG AU/NZ<br />
Handheld portable battery operated spectrum analyzer 100kHz~3GHz.<br />
Resolution bandwidth 1kHz~1MHz. Noise level to 3GHz -112dbm typical,<br />
5-6GHz -102dbm typical. Colour liquid crystal display. Suitable for RF<br />
surveying applications. Includes tracking generator, VSWR bridge and<br />
distance to fault (DTF) options making it suitable for antenna and cable<br />
testing. Four hours of continuous operation on battery power. Cable for<br />
data transfer to PC.<br />
Rohde & Schwarz FSH6 Spectrum Analyser/Tracking Generator<br />
RS,FSH6-TG AU/NZ<br />
Specification as above but capacity is 6GHz.<br />
> NEW<br />
Airmagnet Spectrum Analyser<br />
AIR,AIRMAG SpEC AN AU<br />
Laptop base spectrum analyser. Specifically identify sources of interference<br />
in all Wi-Fi bands 2.4~2.5GHz and 4.9~5.9GHz, and track them to their<br />
physical source. Automatic and real time identification of bluetooth, cordless<br />
phones, microwaves, analog video cameras, RF jammers and more.<br />
Immediately “see” and name each device.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
Spectrum analySerS - high frequency<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
> NEW Rohde & Schwarz FSH3 Spectrum Analyser/<br />
Tracking Generator /Vector Measurements<br />
RS,FSH3-TG-V AU<br />
Handheld portable battery operated spectrum analyser 100kHz~3GHz.<br />
Resolution bandwidth 1kHz~1MHz. Less than -105dbm noise level<br />
(-114dbm typical). Colour liquid crystal display. Suitable for RF surveying<br />
applications. Includes Vector Transmission and Reflection Measurements<br />
option, tracking generator, VSWR bridge and distance to fault (DTF) options<br />
making it suitable for antenna and cable testing. 4h of continuous operation<br />
on battery power. Comes with cable for data transfer to PC.<br />
HP 8591E 1.8GHz Spectrum Analyser<br />
Hp,8591E AU<br />
Range 9kHz~1.8GHz. Resolution 1kHz~3MHz. Card reader allows data<br />
storage and also downloading of a range of measurement options (not<br />
included). Most assets include option 010 tracking generator and option<br />
021 HpIb interface. One analyser includes; option 130 gives 30~300Hz<br />
resolution, option 041 HpIb interface and quasi peak detector and option<br />
103 AM/FM demodulation.<br />
> NEW<br />
Advantest 31.8GHz Portable Spectrum Analyser<br />
ADV,U3771 AU<br />
portable 9k to 31.8GHz spectrum analyser. 3 way power battery, 240V &<br />
DC. RbW 100Hz-3MHz, sensitivity -117 dbm@34 GHz (typ). Includes a<br />
wide variety of data analysis functions & zoom function. With signals applied<br />
to both Input 1 and Input 2, two signals such as an IF signal and a carrier<br />
can be measured. 5 min warm-up, Support for USb for printer and memory<br />
Storage Image formats: pNG, bMp, configuration file bIN, xML. Colour<br />
LCD. OpT.20-High-stability frequency reference crystal.<br />
Advantest R3365A 8GHz Spectrum Analyser with Tracking<br />
Generator<br />
ADV,R3365A AU<br />
Frequency range 100kHz~8GHz. Sensitivity -145dbm. Resolution<br />
10Hz. Adjacent channel leakage power measurement and digital radio<br />
measurement functions. Gated sweep function for TDMA and video signal<br />
analysis. In-built tracking generator 100kHz~3.6GHz. GpIb & RS232<br />
interfaces. Memory card reader.<br />
HP/Agilent E4407B 26.5GHz Spectrum Analyser<br />
Hp,E4407b AU<br />
Frequency range 9kHz~26.5GHz. Resolution bandwidth down to 30Hz.<br />
Noise level -105~-136dbm according to frequency. Centre frequency display<br />
with a resolution of up to 10Hz. Stores up to 200 traces in internal memory<br />
and 200 traces on disk. Some assets include GpIb/parallel interface with<br />
benchlink software (option A4H) and narrow resolution black/white (option<br />
1DR).<br />
RF & MICROWAVE<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 15
Field tested.<br />
Field trusted.<br />
Master every challenge the fi eld throws your way<br />
Field-proven, built to last, and easy to use, the Master family from Anritsu is<br />
the most trusted family of handheld measurement tools for RF and Microwave<br />
fi eld testing. So whatever you need to measure, and wherever you need to test,<br />
you can rely on one of the end-to-end, application-specifi c solutions in our<br />
Master family.<br />
Call 1800 689 685 (Australia only) or visit our US web site www.us.anritsu.com
HP 8593E 22GHz Spectrum Analyser<br />
Hp,8593E AU/MY<br />
Frequency range 9kHz~22GHz. Max resolution 30Hz. Noise level -102~-<br />
127dBm according to frequency. Centre frequency display with a resolution<br />
of up to 10Hz. Some assets include GpIb/parallel and narrow resolution<br />
black/white options (041 & 130).<br />
HP 8582A 22GHz Spectrum Analyser<br />
Hp,8562A MY<br />
RF Spectrum Analyser, 9kHz to 22GHz. resolution 100Hz to 2MHz. HpIb<br />
plotter interface.<br />
HP 8563E Spectrum Analyser<br />
Hp,8563E AU/MY<br />
Range 9kHz~26.5GHz. Resolution 1Hz~2MHz. Sensitivity up to -139dbm.<br />
HPIB plotter and printer interface.<br />
HP 8594E Spectrum Analyser<br />
Hp,8594E MY<br />
Range 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or<br />
less than 122dbm & 5MHz~2.9GHz equal to or less than 127dbm for 30Hz<br />
RBW.<br />
HP 8594E-G Spectrum Analyser with Tracking Generator<br />
Hp,8594E-G MY<br />
Range 9kHz~2.9GHz. Average Noise Level 400kHz~5MHz equal to or less<br />
than 122dbm & 5MHz~2.9GHz equal to or less than 127dbm for 30Hz RbW.<br />
With tracking generator option installed.<br />
Anritsu MS2711A Portable Spectrum Analyser<br />
ANR,MS2711A MY<br />
portable spectrum analyser, 9kHz~3GHz. Light weight battery powered<br />
spectrum analyser with LCD. Resolution bandwidth down to 10kHz.<br />
Suitable for cellular telephone walk or drive tests to determine coverage and<br />
base station positioning. Can also be used for VHF/UHF signal surveying.<br />
N type connector.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
Spectrum analySerS - high frequency<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Anritsu MS2711D 6GHz Spectrum Analyser with Power Meter<br />
ANR,MS2711D-6-29 AU<br />
portable spectrum analyser, 9kHz~6GHz with power meter. Light weight<br />
battery powered spectrum analyser with LCD. Resolution bandwidth from<br />
100Hz~1MHz. Has feature which can identify the type of interfering signal.<br />
Can be used in applications such as cellular telephone walk or drive tests to<br />
determine coverage and base station positioning and also VHF/UHF signal<br />
surveying. Has N type connector.<br />
Anritsu MS2711D Colour Portable Spectrum Analyser<br />
ANR,MS2711D AU<br />
Colour portable spectrum analyser, 9kHz~3GHz. Light weight battery<br />
powered spectrum analyser with colour LCD. Resolution bandwidth from<br />
100Hz~1MHz. Has feature which can identify the type of interfering signal.<br />
Can be used in applications such as cellular telephone walk or drive tests to<br />
determine coverage and base station positioning and also VHF/UHF signal<br />
surveying. N type connector.<br />
> NEW<br />
Anritsu Frequency Converter Module FCN4760<br />
ANR,FCN4760 AU/MY<br />
block down converter for the 4.7GHz~6.0GHz frequency range designed to<br />
work with an ANR,MS2711D (with Option 6). Adds frequency range 4.7GHz<br />
~6.0GHz to the ANR,MS2711D.<br />
RF & MICROWAVE<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 17
RF & MICROWAVE<br />
18<br />
netWOrk analySerS/antenna & cable teSt<br />
Model Type Frequency<br />
ANR,S331b Antenna & cable test set 25MHz~3.3GHz<br />
ANR,S331C<br />
ANR,S331D<br />
Antenna & cable test set 25MHz~4GHz<br />
ANR,S332b Antenna & cable test set plus spectrum analyser 25MHz~3.3GHz<br />
ANR,S332D Antenna & cable test set plus spectrum analyser 25MHz~4GHz<br />
ANR,S820A Antenna & cable test set 3GHz~20GHz<br />
ANR,S820A Microwave antenna and cable test set 25Mhz~20GHz<br />
ANR,C752-05 Antenna & cable test set (75ohm) plus power meter 5MHz~1.2GHz<br />
Hp,8752A Vector network analyser transmission reflection test set 300kHz~3GHz<br />
Anritsu S331D Colour Sitemaster Antenna<br />
ANR,S331D AU/MY<br />
Antenna and cable test set. battery operated with colour display. Frequency<br />
range 25~4000MHz. Measures return loss, SWR, cable loss, and distance<br />
to fault. Integral synthesized signal generator. Return loss range 0~60db.<br />
SWR range 1~65. Distance to fault range 1,197m. Insertion loss range -<br />
120.00~+100db. Cable loss range (one port) 0~30db. Type n(f) port. RS232<br />
interface for printer or pC. Analysis software discs included containing<br />
distance to fault and Smith chart tools. Complete with Instacal calibration<br />
standard, AC/DC adaptor and 12Vdc car cigarette lighter adaptor.<br />
Anritsu S332B Sitemaster including 3GHz Spectrum Analyser<br />
ANR,S332b AU<br />
Antenna and cable test set with spectrum analyser. Frequency range<br />
25~3300MHz for cable and antenna test. 9kHz~3GHz for spectrum analysis.<br />
Measures return loss, SWR, cable loss, and distance to fault. Integral<br />
synthesized signal generator. Return loss range 0.00 to 54.00 db. SWR<br />
range 1.00 to 65.00. Distance to fault rang e 1000 m. Insertion loss range<br />
-120.00 to +100 db. Cable loss range (one port) 0.00 to 20.00 db. Type<br />
n(f) port. RS232 interface for printer or PC. Spectrum analyser resolution<br />
bandwidth down to 10 KHz. Analysis software discs included containing<br />
distance to fault and Smith chart tools. Complete with standard load and<br />
short, AC/DC adaptor and 12 V DC car cigarette lighter adaptor.<br />
Anritsu S332D Colour Sitemaster incl 3GHz Spectrum Analyser<br />
ANR,S332D AU/NZ<br />
Antenna and cable test set with spectrum analyser. battery operated with<br />
colour display. Standard signal table allows automated setup. Frequency<br />
range 25~4GHz for cable and antenna test. 9kHz~3GHz for spectrum<br />
analysis. Measures return loss, SWR, cable loss, and distance to fault.<br />
Integral synthesized signal generator. Return loss range 0~60db. SWR<br />
range 1~65. Distance to fault range 1,197m. Cable loss range 0~30db.<br />
Spectrum analyser resolution bandwidth 100Hz~1MHz. Interfering signal<br />
feature allows identification of type of interference. Type N(f) port. RS232<br />
interface for printer or pC. Analysis software discs included containing<br />
distance to fault and Smith chart tools. Complete with calibration components,<br />
ac/dcadaptor and 12Vdc car cigarette lighter adaptor.<br />
Return<br />
Loss<br />
HP,8753D<br />
30kHz~6GHz<br />
Vector network analyser S parameter test set<br />
HP,8753ES 30kHz~3GHz Yes Yes<br />
HP,8757C<br />
60GHz<br />
Scalar network analyser<br />
HP,8757D 10Mhz Yes Yes<br />
SWR RS232 dc Supply<br />
Yes Yes Yes Yes<br />
Anritsu S820A Microwave Sitemaster 3~20GHz<br />
ANR,S820A AU<br />
Microwave antenna and cable test set. portable (1.14kg) single post<br />
analyser, providing return loss (SWR) insertion loss and distance to fault<br />
measurements in the frequency range of 3.3GHz~20GHz. RS232 interface.<br />
Smith chart and software management tools, ac/dc and automotive adaptor.<br />
A comprehensive range of precision waveguide components and adaptors<br />
are available.<br />
Anritsu S820D Microwave Sitemaster 25MHz~20GHz<br />
ANR,S820D AU<br />
Microwave antenna and cable test set. Portable single post analyser,<br />
providing return loss (SWR) insertion loss and distance to fault measurements<br />
in the frequency range of 25MHz~20GHz. Unit comes standard with<br />
RS232 interface, Smith chart and software management tools, AC/DC<br />
and automotive adaptor. A comprehensive range of precision waveguide<br />
components and adaptors are available.<br />
Anritsu Sitemaster Waveguide Components<br />
ANR,WAVE<strong>GUIDE</strong>-ADAp AU<br />
Calibration components and wave guide to co-ax adaptors for Anritsu S820A<br />
Sitemaster antenna. Set includes 1/8 and 3/8 shorts, termination, and<br />
waveguide to co-ax adaptor.<br />
HP 8753D 6GHz Vector Network Analyser<br />
Hp,8753D AU<br />
Vector network analyser with integral S-parameter test set. Frequency range<br />
30kHz~6GHz with included option 006. In-built 1Hz resolution synthesized<br />
signal source. Calibration kit included.<br />
HP 8753ES 3GHz Vector Network Analyser<br />
Hp,8753ES AU/MY<br />
3GHz Vector Network Analyser allows complete characterization of RF<br />
components. Includes an integrated synthesized source, test set and tuned<br />
receiver. The built-in S-parameter test set provides a full range of magnitude<br />
and phase measurements in both the forward and reverse directions.
HP 8757A Scalar Network Analyser<br />
Hp,8757A AU<br />
Scalar network analyser (Scalar denotes gain measurement only - no phase).<br />
76db dynamic range. Frequency range to 60GHz depending on detector<br />
used. 3 x Hp11664A’s included. Analyser will act as system controller with<br />
HP8350B sweeper. Output to HPIB plotter or HP2225 printer.<br />
HP 8757C Scalar Network Analyser<br />
Hp,8757C AU<br />
Scalar network analyser 10 MHz~40 GHz. 76db (+16 to -60dbm) dynamic<br />
range. Three detector inputs. Two display channels. Color display.<br />
Complete with 3 x Hp,11664A detectors.<br />
HP 8757D Scalar Network Analyser<br />
HP,8757D<br />
Measures insertion loss, gain, return loss, SWR, and power from<br />
10MHz~110GHz.<br />
HP 11679A Detector Extension Cable<br />
Hp,11679A MY<br />
Extension cable for use with Hp,11664A detectors and Hp,8757 network<br />
analysers. Length 7m. Extends the power and detected signal cable<br />
length.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
netWOrk analySerS/antenna & cable teSt<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
HP 85032B Calibration Kit<br />
Hp,85032b AU<br />
Calibration kit for network analysers. Simplified version without adaptors.<br />
> NEW<br />
Emerson Process Management 375 Field Communicator<br />
EME,375 MY<br />
Will configure, test, and diagnose your HART® and Foundation Fieldbus<br />
devices. Able to communicate with any device, by any manufacturer.<br />
Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS pC<br />
Suite Software.<br />
Model Type Frequency<br />
ANR,WIFI-ANTENNA WIFI antenna 2.4GHZ~5.8GHz<br />
ANR,ANTENNA Dipole antenna 25MHz~1.7 GHz<br />
ADV,<strong>TR</strong>1720 Loop vertical antenna system 100kHz~30 MHz<br />
AH,SAS-200/574<br />
18GHz~40 GHz<br />
Double ridge guide horn antenna<br />
AH,SAS-200/571 700MHz~18 GHz<br />
RS,HL013 Log periodic antenna 80MHz~1300 MHz<br />
AN,SAS-200/550 Monopole rod antenna 100kHz~60 MHz<br />
HOL,HI-3002 Isotropic RF radiation monitor 500kHz~6 GHz<br />
NAR,8616 Radio frequency radiator monitor 300MHz~26 GHz<br />
SE,MONITOR 4 Alpha, beta, Gamma and x-Ray radiation monitor<br />
SE,MCIK Gamma x-Ray radiation monitor<br />
field Strength meterS & antennaS<br />
HOL,HI-3004 Isotropic RF low level field strength meter 0.5MHz~6 GHz<br />
WG,ESM-20 personal RF field monitor 1MHz~18 GHz<br />
NAR,8217 Field strength meter for microwave ovens 2.4GHz<br />
ROb,Tx90 Microwave oven leakage detector 2.4GHz<br />
PRO,3201 RF signal analyser & meter 100kHz~2.06GHz<br />
AH,ANTENNA<br />
See also TV Test Equipment<br />
Log periodic antenna 300MHz~12GHz<br />
Advantest <strong>TR</strong>1720 100kHz ~30MHz Antenna<br />
ADV,<strong>TR</strong>1720 AU<br />
Loop and vertical antenna system. Frequency range 100kHz~30MHz.<br />
Suitable for use with ADV,R4131D for field strength and EMI measurements.<br />
Antenna tuner included which can be used as an input/output filter to reject<br />
noise below the measuring frequency.<br />
AH Systems SAS-200/571 Antenna<br />
AH,SAS-200/571 AU<br />
AH,SAS-571 MY<br />
Double ridge guide horn antenna. Frequency range 700MHz~18GHz.<br />
Continuous power 300W. Impedance 50Ω 200V/m max radiated field. Type<br />
N(f) connector.<br />
AH Systems SAS-200/574 18~40GHz Antenna<br />
AH,SAS-200/574 AU<br />
Double ridge guide horn antenna 18~40GHz. Gain in excess of 15db. Type<br />
K(f) connector compatible with 3.5mm connectors including SMA. Complete<br />
with tripod.<br />
AH SAS-200/550-2B 100Hz~60Mhz Rod Antenna<br />
AH,SAS-200/550 AU<br />
Monopole rod antenna. Frequency range 100Hz~60MHz. Active unit with<br />
battery power. Rod height 220mm~1.09m. Ground plane 450 x 450mm.<br />
Antenna factor 0~24.<br />
RF & MICROWAVE<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 19
RF & MICROWAVE<br />
20<br />
field Strength meterS & antennaS<br />
AH Systems 300MHz ~12GHz Antenna System<br />
AH,ANTENNA AU<br />
Log periodic antenna system. Comprises two antennas: A: 300MHz~1.8GHz,<br />
power handling 1kW, antenna factor 15~32db, b: 1~12GHz, power handling<br />
10W, antenna factor 25~44db. Complete with tripod.<br />
Anritsu Dipole Antenna Kit<br />
ANR,ANTENNA AU<br />
Comprises types Mp534A and Mp651A antenna covering 25~520 &<br />
470~1,700MHz. Complete with tripod type Mb9A and coaxial cable.<br />
Anritsu 2.4/5.8GHz WIFI 802.11A/B/G Antenna<br />
ANR,WIFI-ANTENNA<br />
High precision antenna set for wireless network test applications (802.11A/b/<br />
G, 11Mbps &54 Mbps). Includes 2.4GHz and 5.8GHz antennas with reverse<br />
SMA connectors. Also includes precision reverse SMA to N type adapter to<br />
fit standard test equipment.<br />
Rohde & Schwarz HL013 80MHz~1.3GHz Log-Periodic Antenna<br />
RS,HL013 AU<br />
Complete with tripod.<br />
Holaday HI-3002 Field Strength Meter<br />
HOL,HI-3002 AU<br />
Isotropic RF radiation monitor. E-field & H-field probes spanning<br />
500kHz~6GHz (E-field) & 5~300MHz (H-field). Operates from batteries.<br />
Narda 8616 Radiation Hazard Monitor<br />
NAR,8616 AU<br />
Radio frequency radiation monitor complete with probes. Battery operated<br />
with analogue meter and recorder output (3Vdc full scale). Probe type<br />
8623b has a calibrated frequency range of 300MHz~26GHz over a range<br />
of 0.05~100mW/cm2 . (Frequency range up to 8GHz is calibrated to NATA<br />
standard, above 8GHz calibration is to manufacturer’s specifications).<br />
probe type 8633 has a frequency range of 10~300MHz over a range of<br />
0.05~100mW/cm2 .<br />
SE International Monitor 4 Nuclear/X-Ray Monitor<br />
SE,MONITOR 4 AU/MY<br />
Alpha, beta, Gamma & x-ray radiation monitor. Meter, LED & audible<br />
indication. Range; 0~0.5, 5, 50mR/hr, 0~500, 5,000, 50,000CpM, 0~5, 50,<br />
500µSv. Energy sensitivity Alpha 2.5MeV, beta 50KeV, Gamma & x-ray<br />
10KeV. Battery operated.<br />
SE International Monitor MC1K Radiation Survey Meter<br />
SE,MCIK AU<br />
Gamma & x-ray radiation monitor. Meter, LED, and audible indication.<br />
Ranges 0.1~1,000mR/h & 0.01~10mSv/h full scale. battery operated.<br />
mOdulatiOn meterS<br />
Holaday HI-3004 Field Strength Meter<br />
HOL,HI-3004 AU<br />
Isotropic broadband field strength meter designed primarily to measure<br />
low level fields for EMI/EMC studies. Meter scale calibrated in v/m, with<br />
pointer deflection proportional to v2/m2 . Supplied with HSE high sensitivity<br />
E-field probe & STE E-Field probe. HSE probe has 4 ranges, 1v/m ~30v/<br />
mFS, 0.5~1,500Mhz. STE probe has 4 ranges 100v/m~3,000v/mFS,<br />
0.5Mhz~6Ghz. Recorder output (0~1Vdc).<br />
WG ESM-20 Radiation Meter<br />
WG,ESM-20 AU<br />
personal monitor and leakage detector for high frequency electromagnetic<br />
fields. Simultaneous E and H field measurements with audible and visual<br />
alarms. Frequency range H field 1 MHz to 1 GHz; E field 1 MHz to 40<br />
GHz. Operation as personal monitor with compensation for human body<br />
absorption, or with isotropic detection for RF leakage sensing and simple<br />
four-level measurement using LED indicators. battery powered - battery life<br />
over 200 hours.<br />
Narda 8217 Microwave Oven Survey Meter<br />
NAR,8217 AU<br />
Microwave oven survey meter complete with beaker and thermometer for<br />
oven power measurement. Calibration frequency 2.45GHz. Measurement<br />
range 0.5~10mW/cm2 . Battery operated.<br />
Robin Electronics TX90 Microwave Leakage Detector<br />
ROb,Tx90 AU<br />
Microwave leakage detector. Eight dipole analogue meter reading. Ranges<br />
1~10mW/sqcm & 0·1~1mW/sqcm. Display analogue moving coil. power<br />
density accuracy ±1dB. Probe area 2cm2 . Supplied with a manufacturers<br />
certificate of calibration traceable to National Standards. Powered by 9V<br />
alkaline battery.<br />
Protek 3201 RF Analyser/Signal Meter<br />
pRO,3201 AU<br />
RF signal analyser and level meter. Provides spectrum display up to<br />
2.06GHz, audio output, level measurement, and frequency measurement.<br />
Inbuilt antenna. Frequency range 100kHz~2.06GHz with frequency steps<br />
from 5kHz. Modulation types narrow and wide band FM, AM, and SSb.<br />
Level measurement min frequency - narrow band FM 1MHz, wide band FM,<br />
AM, SSb 10MHz. bandwidth - narrow band FM 12.5kHz, wide band FM<br />
180kHz, AM & SSb 2.4kHz. Frequency measurement 9MHz~2.06GHz.<br />
Input impedance 50Ω.<br />
Protek 3290 RF Analyser/Signal Meter 2.9GHz<br />
pRO,3290 AU<br />
RRF signal analyser and level meter. Provides spectrum display up to<br />
2.9GHz, audio output, level measurement, and frequency measurement.<br />
Inbuilt antenna. Frequency range 100kHz~2.9GHz with frequency steps<br />
from 5kHz. Modulation types narrow and wide band FM, AM, and SSb.<br />
Level measurement minimum frequency - narrow band FM 1MHz, wide band<br />
FM, AM, SSb 10MHz. bandwidth - narrow band FM 12.5kHz, wide band FM<br />
180 kHz, AM & SSb 2.4 kHz. Input impedance 50Ω.<br />
Marconi TF2304 Auto AM/FM Modulation Meter<br />
MAR,TF2304 AU<br />
Automatic operation. Frequency 9~12.5MHz & 18~1,000MHz, FM deviation 8 ranges, 1.5~150kHz FS AM depth 3 ranges, 10~30~100%.
Laplace RF Absorbing Clamp<br />
LAp,RF-CLAMp AU<br />
For measurement of emissions from power and other lines to CISPR and<br />
VDE standards. Frequency range 30 MHz~1GHz. Output 50Ω.<br />
Laplace SA1000 EMC Test System<br />
LAp,SA1000 AU<br />
Comprises pC controlled spectrum analyser 10kHz~1.1GHz, SA1020 preamplifier,<br />
RF200 broadband antenna 30MHz~1Hz, TTI LISN1600 LISN,<br />
and RF100 E-field & H-field probes. Supplied with notebook pC and EMC<br />
software.<br />
> NEW<br />
Schaffner Modula-6100 Immunity Test System<br />
SFN,MODULA 6100 AU<br />
Multifunction generator to simulate electro-magnetic field interference effects<br />
for immunity testing in conformity with international, national and in house<br />
standards including the new IEC/EN standards. Generates Interference<br />
pulses such as burst and surge and power quality simulations.<br />
Marconi 2945 Communications Test Set<br />
MAR,2945 AU<br />
Output frequency range 400kHz~1.05GHz. Input frequency range to<br />
modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking<br />
generator with offset tracking inbuilt. power measurement to 150W. Full<br />
duplex operation. AMpS cellular option included. Spectrum analyser with<br />
1kHz resolution. AC mains, external 11~32V and internal battery operation.<br />
RS232C remote control interface.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
emc teSt equipment<br />
Schaffner 438 30kV Static Discharge Generator<br />
SFN,438 AU<br />
Generates an electrostatic charge in a range from 2~30kV. This instrument<br />
is in a ‘gun’ form. Removable discharge network which can be interchanged<br />
with other (optional) impedance networks. performs test to IEC1000-4-2<br />
standards.<br />
> NEW<br />
Schaffner Automated Step Transformer<br />
SFN,INA-6502 AU<br />
Integrated function unit to Modula system. power line dips to 0%, 40%, 70%<br />
and 80%. Complies with EN/IEC 61000-4-11. Includes EUT power control<br />
switch.<br />
Schaffner BestPlus B-1<br />
SFN,bEST+ AU<br />
EMC, ESD, PQT, Burst and Surge Immunity generator simulators. Includes<br />
ESD generator/gun.<br />
Schaffner NSG-420 RF Current Immunity Tester<br />
SFN,NSG-420 AU<br />
provides pre-compliance testing to IEC 801-3 and IEC 801-6. Clamp coupled<br />
to power, data, and signal cables of a device under test. Injects noise signal<br />
from 100kHz~100MHz with a level response from 1MHz~10MHz. AM &<br />
FM modulation of source from a 1kHz oscillator source or an external input.<br />
Indication of signal current from source or existing signal. Also dc recorder<br />
output of this signal. Cable size up to 10 x 22mm. Operates for 1h on 4AA<br />
alkaline batteries.<br />
cOmmunicatiOnS teSt SetS<br />
Marconi 2945A Communications Test Set<br />
MAR,2945A AU<br />
Output frequency range 400kHz~1.05GHZ. Input frequency range to<br />
modulation monitor and spectrum analyser 100kHz~1.05GHz. Tracking<br />
generator with offset tracking in-built. power measurement to 150W. Full<br />
duplex operation. Spectrum analyser with 1kHz resolution. AC mains,<br />
external 11~32V dc on some assets, and external battery operation. RS232C<br />
remote control interface.<br />
HP 8920A Communications Test Set<br />
Hp,8920A AU<br />
RF Communications Analyser test set. Frequency range of 250KHz~1GHz.<br />
Includes an AM/FM signal generator, AM/FM modulation analyser, duplex<br />
offset generator, SSb demodulator, RF power meter, frequency counter, ac/<br />
dc voltmeter, SINAD meter, Distortion meter, oscilloscope and two variable<br />
audio sources. Includes Spectrum analyser with tracking generator. Antenna<br />
& microphone are included.<br />
RF & MICROWAVE<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 21
RF & MICROWAVE<br />
22<br />
pOWer meterS & SenSOrS - rf<br />
Model Type Frequency Power<br />
Hp,E4418A Digital Power Meter<br />
*100kHz~50GHz<br />
*75GHz~110GHz<br />
Hp,E4418b-001 Power meter, high speed, single channel *9kHz~110GHz<br />
Hp,E4419b-001 Power meter, high speed, dual channel *9kHz~110GHz<br />
*100µW~25mW<br />
*-70dbm~44dbm<br />
*100µW~25mW<br />
*-70dbm~44dbm<br />
*100µW~25mW<br />
*-70dbm~44dbm<br />
Hp,8508A Vector voltmeter 100kHz~2GHz 90dB range<br />
bIR,43 RF Thru-line power meter ∆450kHz~2.3GHz<br />
bIR,4391 In-line digital RF power meter<br />
According to element<br />
bIR,4421 In-line RF power meter<br />
bIR,ApM16 Average reading power meter for pCD GSM & CDMA<br />
1.8MHz~32MHz<br />
25MHz~1GHz<br />
0.4~1GHz<br />
1.7~2.2GHz<br />
BIR,ELEMENT Elements for Model 4391 ∆According to element<br />
MAR,6970 Digital power meter ∆According to sensor<br />
∆100mW~10kW<br />
300mW~1kW<br />
2.5W~25W<br />
COL,DC1500A In-line RF power meter dc~0.5 GHz 100W<br />
WAV,FIT RF power & VSWR meter 70MHz~1GHz 20mW~50W<br />
R&S,NRT-Z43-Z44 Directional power meter<br />
30W<br />
200MHz~4GHz<br />
R&S,NRT power reflection meter 30W<br />
* Sensor Dependant<br />
# Element Dependant<br />
Model Type Frequency Power<br />
Hp,8481A<br />
1µW~100mW<br />
10MHz~18GHz<br />
Hp,8484A 0.1nW~10µW<br />
Hp,E9300A<br />
0.1nW~100mW<br />
HP,E9300B<br />
Power Sensor<br />
10Mhz~18GHz<br />
0.1nW~25mW<br />
HP,E9300H 10nW~1W<br />
Hp,8485D 50MHz~26.5GHz 100pW~10µW<br />
RS,FSH-Z1 1.8MHz~26.5GHz 300mW~1kW<br />
> NEW<br />
HP 8508A Vector Voltmeter<br />
Hp,8508A AU<br />
Narrowband measuring technique gives a range of over 90dB and a<br />
sensitivity of 10µV to trace the smallest signal. Measures the phase<br />
difference between its two input channels with at least 0.1º resolution over<br />
a full 180°~-180° range, so they can be used for another complete set of<br />
measurements such as electrical length, phase distortion, or impedance.<br />
100kHz~1GHz with high impedance inputs. 300kHz~2GHz with 50Ω inputs.<br />
Circuit probing to facilitate the design process. Easy programming for ATS’s.<br />
Narrowband measurement capability for high sensitivity applications.<br />
Agilent E4418B Series Power Meter<br />
Hp,E4418b-001 AU<br />
Digital power meter. battery or mains powered. 100µW - 25W (-70dbm<br />
~+44dbm), 9kHz~18GHz (depending on power sensor), 4 digit display<br />
- watts, dbm, db (rel). power sensor required, select and specify when<br />
ordering.
HP E4419B Series Dual Channel Power Meter<br />
Hp,E4419b-001 AU<br />
battery or mains powered dual channel digital power meter. 100µW~25W<br />
(-70dbm~+44dbm), 9kHz~18GHz (depending on power sensor), 4 digit<br />
display - watts, dbm, db (rel). power sensor required, select and specify<br />
when ordering.<br />
Hioki 3134 Digital Power Meter<br />
HIO,3134 MY<br />
AC line power meter, 3 phase W/V/A 1000kw uses two-wattmeter method for<br />
3 wire systems. Can do 4 wire systems. Digital display plus analogue O/p<br />
for all display values V/A/W/VAR. Watts/VAR can both be O/p together to<br />
derive power factor. Supplied with 2x CT’s 3x volts I/p leads in case.<br />
Hioki 3136 Clamp-on Power Meter<br />
HIO,3136 MY<br />
power meter 3ph, 4 wire. FSD 200/1000kW 1kA 600/3V 200/1000 kVAR<br />
recorder O/p 2V/50Ω 40~500Hz complete with 3 x CT’s 9002 unit will<br />
measure 1ph V, A & W. VA & VAR will need to be calculated. On 3ph it will<br />
measure VAR, VA will need to be calculated.<br />
Fluke 36 True RMS ac/dc Clamp Meter<br />
FLU,36 MY<br />
Jaws accept 1 x 750 MCM (1.2 (3mm)) cable or 2 x 500 MCM, (0.98<br />
(24.6mm)) cables up to 38mmØ. True-rms responding. Display 3.5 digit,<br />
2000 count. Rugged design. AC current(45~400Hz), range 600A/200A,<br />
resolution 1A/.1A, accuracy 10~600A ±(2%+3) or 0.5~200A ±(2%+5), crest<br />
factor 2
RF & MICROWAVE<br />
24<br />
pOWer meterS & SenSOrS - rf<br />
> NEW<br />
HP E9300A Power Sensor for HPE4416/18 Power Meters<br />
Hp,E9300A AU/MY<br />
For HpE4416/HpE4418 power meters. 10MHz~18GHz frequency range.<br />
1nW~100mW (-60~+20dbm) power range. 320mW max average power<br />
handling (+25dbm), 2W (+33dbm) peak power ( NEW<br />
Agilent Power Sensor 1µW~25W, 10MHZ~8GHz<br />
Hp,E9300b AU<br />
power sensor for Hp EpM series power meters. E-series average power<br />
sensor. 10MHz~18 GHz, 1µW~25W (-30dbm~+44dbm).<br />
> NEW<br />
HP 8485D Power Sensor 100pW~10uW, 50MHz~26.5GHz<br />
Hp,8485D AU<br />
power Sensor 100pW to 10uW, 50MHz to 26.5GHz.<br />
> NEW<br />
Rohde & Schwarz Power Sensor for RS,FSH 10MHz~8GHz<br />
RS,FSH-Z1 AU<br />
power sensor for RS,FSH 10MHz~8GHz. 200pW~200mW<br />
(-67dbm~23dBm).<br />
HP E9300H Power Sensor 10nW~1W, 10MHz~18GHz<br />
Hp,E9300H AU<br />
power sensor for Hp EpM series power meters. E-series Average power<br />
Sensor. 10 MHz~18 GHz, 10nW~1W (-50dbm~+30dBm).<br />
HP 8481A 10MHz~18GHz Power Sensor for HP43X Series<br />
Meters<br />
Hp,8481A AU<br />
For Hp436A, HpE4418b & HpE4419b. 10MHz~18GHz, 1µW~100mW.<br />
HP 8484A 10MHz~18GHz Power Sensor<br />
Hp,8484A AU<br />
power sensor 10MHz~18GHz, 0.1nW~10µW. Complete with Hp,11708A<br />
30dB reference attenuator.<br />
Marconi 6910 Power Sensor<br />
MAR,6910 MY<br />
Frequency range 10MHz~20GHz. power range -30dbm~20dbm<br />
(1μW~100mW). Max RF i/p 25dbm (300mW) CW 42dbm (15W) peak<br />
for 2μs. Sensing element semiconductor thermocouple. VSWR 1.25<br />
10MHz~30 MHz, 1.1 30MHz~2GHz, 1.18 2~16GHz, 1.28 16~18 GHz, 1.4<br />
typical 18~20GHz. Linearity factor provided with sensor. Accuracy ±0.5% at<br />
25C between 10 & 20dBm. Improves by a factor of 10 for each lower rang.<br />
Calibration factor provided with sensor. Accuracy uncertainty provided with<br />
sensor. Resolution 0.01%. RF connector precision N-type (M) 50Ω.<br />
Marconi 6912 Power Sensor<br />
MAR,6912 MY<br />
Frequency range 30kHz~4.2GHz. I/p power range 30dbm (1μW) to 20dbm<br />
(100mW).<br />
Marconi 6913 Power Sensor<br />
MAR,6913 MY<br />
Frequency range 10MHz~26.5GHz. I/p power range 30dbm (1μW) to 20dbm<br />
(100mW). Max 25dbm (300mW) CW, 42dbm (15W) peak for 2μs. Sensing<br />
element semiconductor thermocouple. VSWR 1.40 10MHz~50MHz, 1.15<br />
50MHz~100MHz, 1.10 100MHz~2GHz, 1.15 2~12.4GHz, 1.20 12.4~18GHz,<br />
1.25 18~26.5GHz. Calibration factor provided at 1GHz intervals (500MHz<br />
intervals above 20GHz) with each sensor. Accuracy uncertainty provided<br />
with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5% at<br />
100mW, decreasing by 0.005% per 1mW.<br />
Marconi 6920 Power Sensor<br />
MAR,6920 MY<br />
High sensitivity diode sensor. Frequency range 10MHz~20GHz. I/p power<br />
range 70dbm (0.1nW) to -20dbm (10μW), max 26dbm (400mW) CW<br />
+30dbm (1W) peak for 2μs. Sensing element Shottky barrier diode. VSWR<br />
1.4~1.2 10~40MHz, 1.20 40MHz~10GHz, 1.35 10~18GHz, 1.40 typical<br />
18~20GHz. Calibration factor provided at 1GHz intervals with each sensor.<br />
Accuracy uncertainty provided with each sensor.<br />
Marconi 6923 RF Power Sensor<br />
MAR,6923 MY<br />
High sensitivity diode sensor. Frequency range 10MHz~26.5GHz. I/p<br />
power range -65dbm (0.3nW) to -20dbm(10μW), max 26dbm (400mW)<br />
CW, +30dbm (1W) peak for 2μs. Sensing element Shottky barrier diode.<br />
VSWR 1.4 10~40MHz, 1.15 40~100MHz, 1.12 0.1MHz, 1.17 2~8GHz, 1.30<br />
8~18GHz, 1.50 typical 18~26.5GHz. Calibration factor provided at 1GHz<br />
intervals with each sensor. Accuracy uncertainty provided with each sensor.<br />
Resolution 0.01%. Linearity factor provided with each sensor. Accuracy<br />
±1% between -30 & -20dbm. RF connector type N (M) precision 50Ω.
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
rf attenuatOrS<br />
Model Type Attenuation (dB) Frequency (GHz) Power Max (W)<br />
Hp,8494b-8496b<br />
121<br />
Hp,8494b 11<br />
Coaxial step attenuator<br />
Hp,8495b 70<br />
Hp,8494/5b 81<br />
dc~18<br />
Hp,8495D Step attenuator 70 dc~26.5<br />
WEI,33-10-34<br />
WEI,46-03-34 3<br />
Fixed<br />
WEI,46-06-34 6<br />
10 dc~8 25<br />
WEI,34-30-34 30 dc~4 24<br />
WEI,46-10-34 10<br />
WEI,46-20-43 20<br />
WEI,82-30-34 Coaxial attenuator 30 dc~3 1000<br />
WEI,AS6 Calibrated attenuator 3<br />
WEI,AS20 Variable attenuator 30 dc~26.5 2<br />
dc~18<br />
WEI,M2020 Attenuator 20 dc~18<br />
bIR,25A-10 Fixed 10 dc~4 25<br />
NAR,705-69 Attenuator 30 dc~18 25<br />
Weinschell 33-10-34 25 W 10dB 8.5GHz RF Attenuator<br />
WEI,33-10-34 AU<br />
10db, 25W, dc~8GHz. Type N connectors.<br />
Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator<br />
WEI,34-30-34 AU<br />
30db, 25W, dc~4GHz. Type N connectors.<br />
Weinschell 46-03-34 50W 3dB 18GHz RF Attenuator<br />
WEI,46-03-34 MY<br />
Weinschell 46-06-34 50W 6dB 18GHz RF Attenuator<br />
WEI,46-06-34 MY<br />
DC - 18GHz, 6 db, average power 25W, 200W peak. Type N connector.<br />
Weinschell 46-10-34 50W 10dB 18GHz RF Attenuator<br />
WEI,46-10-34 MY<br />
DC - 18GHz, 10 db, average power 25W, 200W peak. Type N connector.<br />
Weinschell 46-20-43 25W 20dB 18GHz RF Attenuator<br />
WEI,46-20-43 AU/MY<br />
DC~18GHz, 20db, 25W. Type N connectors.<br />
> NEW<br />
Weinschel 82-30-34, 30dB 1000W 3GHz Coaxial Attenuator<br />
WEI,82-30-34 AU<br />
30db 1000W 3GHz Coaxial Attenuator. DC to 3GHz.<br />
Weinschell AS6 Calibrated Attenuator Set<br />
WEI,AS6 MY<br />
Frequency range DC-18GHz, set consists of 4 different nominal value 3, 6,<br />
10 & 20db. Connector type N per mil-STD-348, power rating 5W.<br />
Weinschell AS20 Precision Attenuator Set<br />
WEI,AS20 AU<br />
DC~26.5GHz. Attenuator values 6,10,30 db. Average power 2W.<br />
3.5mm connectors.<br />
Weinschell M2-20 Attenuator<br />
WEI,M2-20 MY<br />
20 db attenuator. DC to 18GHz, double male N type<br />
HP 8494B/8496B Attenuator Set 121dB x 1dB<br />
Hp,8494b-8496b AU<br />
Coaxial step attenuator set. DC-18GHz. 0.11db in 1db steps and 10-110<br />
db in 10db steps. Comprises a connected set of types 8494b & 8496b with<br />
11716A rigid interconnect kit. Type N(f) connectors.<br />
HP 8494B 11 x 1dB 18GHz Coaxial Step Attenuator<br />
Hp,8494b AU<br />
DC~18GHz. 0~11db in 1db steps. 1W average power handling. Option<br />
001. Type N(f) connectors.<br />
HP 8495B 70dB x 10dB Coaxial Step Attenuator<br />
Hp,8495b AU<br />
DC~18GHz. 0~70db in 10db steps.<br />
HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB<br />
Hp,8494/5b AU/MY<br />
DC~18GHz. 0~11db in 1db steps. 11~81db in 10db steps. Comprises a<br />
connected set of types 8494b & 8495b. Type N(f) connectors.<br />
HP 8495D 70dB 26.5GHz Step Attenuator<br />
Hp,8495D AU/MY<br />
70db step attenuator in 10db steps. Frequency range dc~26.5GHz. Max<br />
continuous power 1W. Note attenuator uses 3.5mm connectors.<br />
RF & MICROWAVE<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 25<br />
1<br />
50<br />
25
RF & MICROWAVE<br />
LOW FREQUENCY<br />
26<br />
rf attenuatOrS<br />
BIRD 25-A-MFN-10 10dB 25W 4GHz ATTENUATOR<br />
bIR,25A-10 AU<br />
RF Attenuator, DC~4GHz, 10db, 25W, .<br />
Bird 808 RF Co-axial Resistor 25W 50Ω<br />
bIR,8080 MY<br />
50Ω, 25 W, DC-3500MHZ. Dummy Load.<br />
filterS<br />
Krohn-Hite 3550 Bandpass Filter<br />
KRO,3550 AU<br />
band pass, band reject, low pass, high pass filter. Frequency range 2Hz~200kHz. bandwidth 2Hz~3MHz. Max attenuation 62db. Slope 24db per octave.<br />
rf acceSSOrieS<br />
HP 85021A RF Directional Bridge<br />
Hp,85021A AU<br />
For Hp,8757A scalar network analyser.<br />
HP 11667A Power Splitter<br />
Hp,11667A AU<br />
For Hp,8757A scalar network analysers, dc~18GHz, 0.5W max. N (F)<br />
connector on all ports.<br />
HP X281A WR-90, 1-079 to N(F) Adaptor<br />
Hp,x281A AU<br />
8.2~12.4GHz waveguide to type N (F) adaptor.<br />
HP P281B-013 WR-62, 1-089 to Coax Adaptor<br />
Hp,p281b AU<br />
12.4~18GHz waveguide to type N(f) adaptor.<br />
HP S281A WR-284 to N(F) Adaptor<br />
Hp,S281A AU<br />
2.6~3.95GHz waveguide to type N (F) adaptor.<br />
RF Connector Kit N, BNC, TNC, SMA, APC7<br />
<strong>TR</strong>,RF-CONN AU<br />
RF connection adaptors. Comprises 10 couplers with interchangeable<br />
connectors; 3 x N, bNC, SMA, & 1 x TNC, all (M) & (F). Includes ApC~7 to<br />
N (F) adaptor.<br />
lf Signal generatOrS<br />
Tektronix ASG100 Audio Generator<br />
TEK,ASG100 MY<br />
Dual CH for stereo applications. balanced i/p & o/p. Connects in-line for<br />
easy test signal insertion. Quick identification of insertion pt with voice ID.<br />
Short duration audio test sequence for rapid automatic checkout of audio<br />
lines. Single button selection of line-up tone. Manual mode allows selection<br />
of freq & amplitude. RS-232 for remote control.<br />
diStOrtiOn analySerS<br />
HP 8903B-010-051 Audio Analyser<br />
Hp,8903b AU<br />
Audio analyser for communications and other applications. Measures<br />
distortion, sinad, signal-to-noise, ac V, dc V, frequency. Low distortion<br />
programmable sine wave source. Frequency range 20Hz~100kHz. Optional<br />
400Hz high pass and CCITT weighting filters fitted.<br />
Narda 705-69 69 x 1dB GHz Attenuator<br />
NAR,705-69 MY<br />
Step Attenuator. 0 - 69db in 1db steps. Frequency range DC - 18GHz<br />
HP 11692D Dual Directional Coupler<br />
Hp,11692D MY<br />
Frequency range 2~18GHz.<br />
HP 778D Dual Directional Coupler<br />
Hp,778D AU<br />
Frequency range 100MHz~2GHz.<br />
HP 908A Coaxial Termination<br />
Hp,908A AU<br />
DC~4GHz. Max power 0.5W average.<br />
HP 11852A Min Loss Pad 50 ~75Ω<br />
Hp,11852A AU<br />
Low SWR min loss pad for use with 50Ω network analysers or other<br />
instruments to allow connection to 75Ω cables and devices.<br />
Radiall R-404850 RF Termination<br />
RAD,R-404850 AU<br />
RF load. 100W, 50Ω, dc~4GHz. Type N (M).<br />
Flann 1713320 Waveguide Directional Coupler<br />
FLA,1713320 AU<br />
20dB.<br />
Genrad 1390B Random Noise Generator<br />
GR,1390-b AU/MY<br />
Frequency range 5Hz~5MHz, range selectable 20kHz, 500kHz & 5MHz.<br />
Output level 3V, 2V, 1V for each frequency range respectively. Gaussian<br />
output. Frequency response 1db, 20Hz~20kHz. pink noise filter optional.<br />
Trend Type 3 Distortion Generator<br />
<strong>TR</strong>E,TYpE 3 AU<br />
Distortion generator.
NEW<br />
Rohde & Schwarz EFA TV Test Receiver 43<br />
RS,EFA43 AU<br />
DVb-T test receiver, fully compatible with the ETS300 744 standard, receives,<br />
demodulates, decodes and analyzes OFDM (orthogonal frequency division<br />
multiplex) signals. All key parameters for demodulating the receive signal<br />
can be selected automatically or manually. Features, 7MHz SAW filter.<br />
6MHz, 7MHz or 8MHz operating bandwidth. 2K or 8K OFDM modulation.<br />
QpSK, 16QAM or 64QAM constellation diagram. 1/2, 2/3, 3/4, 5/6 or 7/8<br />
code rate. 1/4, 1/8, 1/16 or 1/32 guard interval. Hierarchical demodulation.<br />
Reed-Solomon error correction 204/188.<br />
> NEW<br />
Promax TV Explorer Prodig-5<br />
pRO,pRODIG-5 AU<br />
For the installation, maintenance and surveillance of terrestrial, satellite and<br />
cable TV systems. Automatically provides information about the channels<br />
available in the network and their quality. Displays analogue and digital<br />
channel picture. Includes a high resolution spectrum analyser function and<br />
MPEG decoding. Foxtel approved.<br />
Promax Prolink 4C Premium Analogue/Digital TV Test Set<br />
pRO,pROLINK4C-pREM AU<br />
Measures terrestrial, satellite and cable TV systems including analogue and<br />
digital VHF & UHF bands. built in colour monitor provides measurement<br />
readout and can be used to display video signal. Measurement functions<br />
include spectrum analysis, direct signal level readout, carrier to noise,<br />
channel power, digital carrier to noise, digital bit error ratio (BER) and digital<br />
QAM constellation. DVb digital TV channel identifier. Logs to pC and<br />
includes software for remote control and channel plan management.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
tv teSt equipment<br />
Tektronix 1741 Vectorscope/Waveform Monitor<br />
TEK,1741 AU<br />
pAL waveform monitor and vectorscope for television and video use.<br />
Unaohm S20 & Datum 10 Digital TV Meter Combo Meter<br />
UNA,DATUM10-S20 AU<br />
Comprises S20 Satellite digital and analogue television bit error rate meter<br />
and Datum 10 terrestrial digital and analogue television instrument.<br />
Barco Quasar Modulator<br />
bAR,MODULATOR AU<br />
Digital television signal converter. Rack mounted. Supports a full range of<br />
variable data rates, signal bandwidths and constellations. Complies with<br />
ITU-TJ.83 standards, annex A (DVb), b (open cable) & C Japan. ASI input<br />
interface (with active loop-through). Variety of input interfaces available. bit<br />
stuffing on/off and pCR re-stamping. Static pID filtering. Tuneable or fixed<br />
output RF frequency. IF loop. Front panel RF testpoint (-20db). 60dbmV<br />
(rms) output level. Front panel LCD and buttons for easy set-up. Full remote<br />
control and diagnostics with ROSA management. back-up and automatic<br />
level control available with ROSA.<br />
TELEVISION TEST EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 27
DATA, NETWORK & TELECOMMUNICATIONS<br />
28<br />
telecOmmunicatiOnS<br />
> NEW Nettest Lite 3000E Signalling Analyser for<br />
Telecommunications Systems<br />
GNE,L3000E-ND AU<br />
Simultaneous monitoring in both directions of 2Mb/s pCM lines. Tests framed<br />
Nx64 Kb/s & unframed 2Mb/s pCM systems. Remote operation with MS<br />
Windows. Frame Relay installation testing, trouble shooting & decode. Alllayer<br />
protocol analysis and decode options for ISDN. ISDN Call Emulation<br />
option provides the necessary functionality for testing ISDN connections,<br />
can setup and receive ISDN calls with user-specified parameters.<br />
Anritsu ME538MLA TX & RX Microwave Link Analyser<br />
ANR,ME538M AU<br />
Measures group delay, modulator/demodulator linearity & sensitivity,<br />
differential gain & phase, IF/bb amplitude response, IF/bb return loss,<br />
frequency spectrum & deviation, am to pm conversion coefficient, power,<br />
gain attenuation and dc characteristics. Features: LED display, autorange<br />
CRT, push button parameter selection and remote monitoring. 70/140MHz<br />
bands: 83.333, 250, 500kHz & 2.4, 3.58, 4.43, 5.6, 8.2, 12.39MHz.<br />
Nettest EPE06/7 2,8,34,140 MPPS BERT<br />
GNE,EpE06/7 AU<br />
pCM bERT tester for 2, 8, 34 & 140 Mb pCM systems. performance<br />
according to G.821 with BNC type connectors. For unbalanced inputs.<br />
Nettest MPA7400 Multichannel Signalling Protocol Analyser<br />
GNE,MpA7400 AU<br />
Multichannel telecom protocol analyser for detailed analysis of signalling<br />
systems such as SS7. Able to analyse 4 channels at the same time. Some<br />
emulation capability. Additional protocol decodes available on request.<br />
Unit is currently set up to handle signalling analysis for cellular telephone<br />
exchanges.<br />
Trend Aurora Sonata BRA/PRI ISDN Test Set<br />
<strong>TR</strong>E,AURORA-SONATA AU<br />
bRI/pRI/pOTS test set. provides simulation and monitor capabilities for<br />
Primary Rate, Basic Rate, and POTS services. Provides decoding of ETSI<br />
ISDN protocols. Has S,U,E1 and RJ11 pOTS interfaces. battery operated<br />
hand held device.<br />
W&G/Acterna IBT-10U Basic Rate ISDN Test Set<br />
WG,IbT-10U AU<br />
performs bERT, protocol analysis to level 3 includes both S & U interface.<br />
Features include: NT simulation, telephone and tracer function, x.25 on D<br />
channel and B channel, measurement of supply voltages.<br />
Nettest Lite 3000E Signal Analyser<br />
GNE,L3000E AU<br />
Signaling analyzer for telecommunications systems. Framed Nx64 Kbps<br />
and unframed bERT testing, in-service and out-of-service error performance<br />
measurements G.821/G.826/M.2100. balanced and unbalanced interface.<br />
Has functionality for G.703, AbIS, SS7, and ISDN for use in both wired and<br />
wireless (cellular GSM) applications. Provides comprehensive test and<br />
measurement of data transmission lines on RS232/V.24 async & sync, x.21/<br />
V.11, V35, RS422/485/449/V.36, RS-530, DCE or DTE. Detailed analysis<br />
and graphical representation on large colour display. Remote operation with<br />
MS Windows.<br />
Digital Lightwave NIC 2.5G STM16 2.5Gb SDH Test Set<br />
DLW,NIC2.5G AU<br />
Portable analyser with touch screen PC. Testing at SDH rates of<br />
STM0/1/4/16 (52,155,622Mb/s & 2.5Gb/s). Tests pDH at E1,E3, E4, DS1 &<br />
DS3 (2,8,140,1.5 & 45Mb/s). Dual wavelength (1310/1550nm). SC Optical<br />
connectors. Tests include BERT, level, protocol decoding & analysis and<br />
ATM analysis. Complete in portable hardcase.<br />
Digital Lightwave NIC10G STM16/64 SDH Analyser<br />
DLW,NIC10G AU<br />
Network information computer. Verifies and qualifies the performance of<br />
OC-192c/OC-48c SONET, STM-64/STM-16 (10/2.5Gbps) SDH and DWDM<br />
telecommunications networks. Optical interfaces (1550/1310nm for STM16<br />
& 1550nm for STM64). Includes concatenated payload support and OC-<br />
48/STM-16 add/drop. 10.4” active matrix touch screen GUI operation.<br />
Measures optical power and frequency. pCMCIA slots for memory cards<br />
and peripherals.<br />
Digital Lightwave NICPlus 10G SDH Tester with Gb Ethernet<br />
DLW,NICpLUS10G AU<br />
portable Gb/OC-192/STM-64 Network Information Computer (5 slot<br />
chassis). Multirate interface for STS-1 OC-1/3/3c/12/12c/48/48c STM-<br />
0e/1e/0/1/1c/4/4c/16/16c and interface for OC-192/192c STM-64/64c with<br />
the ability to monitor down to the STS-1/STM-0 level inside of any supported<br />
optical rate. Use to verify & qualify the performance of SDH & DWDM & GbE<br />
telecomm networks. Electrical & optical interfaces (1550nm for 10G, all other<br />
rates 1310/1550). Includes concatenated payload support & OC-48/STM-16<br />
add/drop. G.709/975 OTU 1 / OUT 2 FEC software installed 10.4 inch active<br />
matrix touch screen GUI operation. Measures optical power and frequency.<br />
pCMCIA slots available for memory cards and peripherals.<br />
Fluke 990DSL CopperPro Telecom Line & DSL Test Set<br />
Analyser<br />
FLU,990DSL AU<br />
CopperPro wide range Plain Old Telephone Services (POTS) fault location<br />
and line qualification capabilities. Includes Wideband/TDR option which<br />
adds high frequency transmission testing and qualification functions for<br />
services like ADSL, HDSL, HDSL2, HDSL4, ISDN, T1, E1 and DDS. TDR<br />
feature adds precise fault location and analysis. Includes TN2100 remote<br />
terminator.<br />
W&G/Acterna ANT 20 SDH/PDH Analyser<br />
WG,ANT20 AU<br />
Interfaces for pDH data streams at 2, 8, 34, & 140Mb/s, electrical and optical<br />
interfaces for SDH at STM1 (155Mb/s). Jitter and wander generators and<br />
analyser options are fitted. Internal PC with FDD for transferring results.<br />
Serial, parallel, keyboard and pen interfaces.<br />
Aegis GPset Telecom Pair ID & Intercom<br />
AEG,GpSET AU<br />
For telecommunications cable work. Typically used by Telstra contractors.<br />
Intercom function available on live or unpowered lines.
NEW<br />
Fluke Networks Etherscope Gigabit W-LAN Analyser<br />
FLU,ETHERSCOpE-WLAN AU<br />
Etherscope extended kit full duplex 10/100/gigabit LAN & WLAN 802.11a/<br />
b/g analyser. Handheld analyser for discovery of network elements and<br />
fault location. Discovers devices by Ip subnets, NetbIOS domains, and Ipx<br />
networks. VLAN discovery shows interface status, connected host details,<br />
and trending data. Allows measurement of device details and statistics.<br />
Complete with cable ID accessory for tracking cable routes.<br />
> NEW<br />
Fluke Nettool LAN Analyser<br />
FLU,NETTOOL AU<br />
VoIp monitoring. bi-directional LAN test tool. Diagnose VoIp phone bootup<br />
problems, call control and measure key call quality metrics. Compatible<br />
with IP phones employing either SIP or SCCP call control protocols. VoIP<br />
Log displays call control events, QoS configuration, and call quality metrics.<br />
boot Log displays key boot events such as DHCp address acquisition, DNS<br />
lookup of call servers and gateways, downloading of operating files, and call<br />
server registration. Inline testing of LANs at the workstation level. Tool is<br />
plugged in-line between workstation and LAN. provides indications of NIC<br />
and hub functionality, cable connectivity, and protocol compatibility between<br />
LAN and workstation. Use as a first line fault finding tool for IT departments.<br />
Airmagnet Portable 802.11 a/b/g Survey System<br />
AIR,AIRMAGNET-SURVEY AU<br />
portable wireless network survey tool for 802.11a, 802.11b and 802.11g<br />
wireless networks (5 & 2.4GHz). provides mapping of wireless network<br />
coverage with optional GpS location facility. pre-loaded on laptop computer<br />
with approved wireless network card.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
lan analySerS/management<br />
Airmagnet Portable 802.11 a/b/g Wireless Network Analyser<br />
AIR,AIRMAGNET-<strong>TR</strong>IO AU<br />
portable wireless network analyser for 802.11a, 802.11b and 802.11g<br />
wireless networks (5 & 2.4GHz). Validates WEp, 802.1x, LEAp, TKIp,<br />
MIC, VPNs. Provides security policy validation and intrusion detection.<br />
Detects denial of service attacks. provides active performance analysis and<br />
identifies and pinpoints WLAN Faults. Includes Find Tool for tracking down<br />
rogue devices and 70+ configurable alarms with expert advice. pre-loaded<br />
on p3 notebook computer.<br />
Airmagnet Portable Wireless Network Analyser<br />
AIR,AIRMAGNET-pRO AU<br />
Validates WEp, 802.1x, LEAp, TKIp, MIC, VpNs. provides security policy<br />
validation and intrusion detection. Detects denial of service attacks. provides<br />
active performance analysis and identifies and pinpoints WLAN Faults.<br />
Includes Find Tool for tracking down rogue devices and 70 + configurable<br />
alarms with expert advice. built-in site survey utility with GpS support.<br />
Fluke Networks Etherscope Gigabit LAN Analyser<br />
FLU,ETHERSCOpE-Ex AU<br />
Etherscope extended kit full duplex 10/100/Gb LAN analyser. Handheld<br />
analyser for discovery of network elements and fault location. Discovers<br />
devices by Ip subnets, NetbIOS domains, and Ipx networks. VLAN<br />
discovery shows interface status, connected host details, and trending data.<br />
Allows measurement of device details and statistics. Complete with cable ID<br />
accessory for tracking cable routes.<br />
Fluke Optiview Pro Gigabit 10/100/Gigabit LAN Analyser<br />
FLU,OpTIVIEW-GIG AU<br />
FLU,OpTIVIEW NZ<br />
provides network analysis on 10/100/Gigabit Ethernet networks (multimode<br />
fibre & copper). Active discovery in switched networks, full 7 layer analysis,<br />
fully automatic Ip configuration even without DHCp, address-to-name<br />
mapping, packet capture and decode, SNMp device analysis, RMON II<br />
traffic analysis. Gigabit testing capabilities, and basic cable testing (wiremap,<br />
return loss, etc).<br />
HP J3446C 10/100 Ethernet Analyser<br />
Hp,J3446C AU<br />
Has RJ45 and AUI ports. AUI ports allow fibre or co-ax connections to be<br />
made with appropriate adaptor (adaptor not supplied). For use with HP<br />
internet advisor undercradles for FDDI or similar analysis.<br />
DATA, NETWORK & TELECOMMUNICATIONS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 29
DATA, NETWORK & TELECOMMUNICATIONS<br />
30<br />
Network problem solver? Meet your new assistant.<br />
EtherScope<br />
Network Assistant<br />
lan analySerS/management<br />
HP J2524A FDDI Under Cradle<br />
Hp,J2524A AU<br />
For the Hp,J2302A or Hp,J2523A/b. Includes Tp/pMD on STp/Db-9 or<br />
UTp/RJ-45, 32Mb data.<br />
HP J2523A Ethernet/Token LAN Analyser<br />
Hp,J2523A AU<br />
Housed in a ruggedised laptop style colour computer. Includes Hp’s latest<br />
Drill Down Expert Software.<br />
Network General Sniffer - Ethernet /Token Ring<br />
NG,SNIFF-COMb AU<br />
Housed in a colour Toshiba T6600. Analyser provides 3 applications for<br />
network analysis and monitoring. protocol interpretation for over 140<br />
protocols, monitoring features, and expert analysis to help identify LAN<br />
problems. Oracle database decodes also available.<br />
Network General 10/100Mb/s Ethernet Protocol Analyser<br />
NG,SNIFF-10/100 AU<br />
10mbps and 100mbps Ethernet protocol analyser for 10/100 base<br />
T networks. Unit supplied with RJ45 connections only.<br />
Network General Sniffer WAN Interface<br />
NG,SNIFF-WANpOD AU<br />
Enables the Network General Sniff-pro98 to perform WAN as well as LAN<br />
analysis. With interface and cables for RS232/V24, V35, RS449/422 and<br />
x.21. Must be used with NG,SNIFF-pRO98. performs E1/ISDN primary<br />
rate analysis.<br />
N E T W O R K S U P E R V I S I O N TM<br />
Introducing the EtherScope Network<br />
Assistant – your eyes into the network to<br />
help you spot problems and solve them<br />
faster than ever. You don’t have time for trial<br />
and error. Or methods that only provide part<br />
of the picture. That’s why Fluke Networks’ new<br />
EtherScope analyzer, with its immediate<br />
discovery and fast diagnostics, helps you<br />
quickly isolate urgent problems on your gigabit<br />
network as well as those nagging issues that<br />
may be keeping it from performing at optimum<br />
level. Fast. Accurate. EtherScope.<br />
Your network assistant is waiting<br />
to show you what it can do to help<br />
make your job easier. Just go to<br />
www.flukenetworks.com/EtherScope<br />
and take a tour of the virtual demo.<br />
W&G/Acterna DA-30 Dual Protocol Analyser<br />
WG,DA-30 AU<br />
Easy to use Windows-based interface with in-built trackball. provides<br />
measurement of physical characteristics of interfaces, protocol analysis of<br />
LAN and WANs, testing of LAN/WAN interconnection devices, simultaneous<br />
analysis of any combination of LANs and WANs. Ethernet and Token Ring<br />
interface complete with all major layer protocol suites. WAN configuration:<br />
V.35, x.21 with “high speed” WAN feature module allowing speeds up to<br />
2Mbps. Includes 16/4Mbps Token Ring interface, Ethernet,HS-WAN, V35-<br />
V28 & x21 interfaces. pAM module included.<br />
W&G/Acterna Domino Gigabit<br />
WG,GIGAbIT AU<br />
For monitoring, troubleshooting, and simulation of Gigabit Ethernet networks.<br />
provides full line rate, full duplex analysis of Gigabit Ethernet networks. All<br />
transmit, capture, filtering, and statistics are provided at full line rate. Expert<br />
analysis software provides easy diagnosis of network faults, and decodes<br />
over 300 protocols. Link configuration status is detected automatically and<br />
equipment auto configures itself to suit the detected status. Provided with<br />
hot swappable modules for single mode and multi mode fibre interfaces<br />
(Lx & Sx interfaces). Complete with laptop computer configured for the<br />
analyser.
Nettest Winpharaoh LAN/WAN Analyser<br />
GNE,WINpHARAOH AU<br />
Capable of 10/100Mbps ethernet and up to 2Mb WAN with the following<br />
interfaces: V.35, RS-232, RS-449, EI and V.11. pRI and bRA ISDN ability.<br />
Report writing software installed for quick overview of network status.<br />
Nettest Winpharoah 2 LAN/WAN Analyser<br />
GNE,WINpHARAOH2 AU<br />
Capable of 10/100Mbps Ethernet and up to 2Mb WAN with the following<br />
interfaces: V.35, RS-232, RS-449, and V.11/x.21. Has bERT testing<br />
for WAN. Report writing software installed for quick overview of network<br />
status.<br />
Spirent/Netcomm Smartbits SMB200 Router Tester<br />
SpI,SMb200-10/100 AU<br />
4 port 10/100 ethernet/STM1 ATM system for determining router performance<br />
including latency, latency variation and jitter. Can be used to load network<br />
with specific definable traffic to determine routing performance and discover<br />
throughput bottlenecks. System includes 4 x ML7710 10/100 interface<br />
cards.<br />
HP 4951C 19.2Kbps Protocol Analyser<br />
Hp,4951C AU<br />
Serial data and protocol analyser. 50~19,200 baud data transfer rates<br />
for monitoring, simulating and triggering. Data codes: ASCII, EbCDIC,<br />
bAUDOT, six bit transcode (SbT), IpARS and EbDIC. protocols: x.25. bSC,<br />
HDLC, SDLC, IpARS and user definable. Error checking: CRC-CCITT,<br />
CRC-6/12/16, LRC, parity and block error rate testing (bERT), 5, 6, 7 or 8<br />
bit per character parity, 1,1.5 or 2 stop bits. Full ASCII keyboard, up to 63<br />
triggers, 32kb buffer memory, 618kb integral microfloppy drive, video output,<br />
separate printer output. Complete with Hp,18179A RS-232C/V24 interface<br />
with full breakout box.<br />
HP 4957A 64Kbps Protocol Analyser<br />
Hp,4957A AU<br />
protocol analyser. For up to 64kb/s (option included for asynchronous 8bit<br />
and NRZ/NRZI bit oriented protocols up to 256 kbps). protocols include<br />
ISDN Q.921, x.25, SDLC, HDLC, IpARS, bSC, ASYNC, and most character<br />
synchronous protocols, (option included for x.21). bERT function. Data<br />
codes ASCII, EbCDIC, bAUDOT, 6 bit transcode (SbT), IpARS, EbCD and<br />
HEx. 32 kb non-volatile memory, 786 kb volatile memory, 613kb microfloppy,<br />
128kb non-volatile RAM disk. Complete with RS-232C, RS-449 and V35<br />
interfaces, printer and video outputs.<br />
Nettest Fastnet Probe<br />
GNE,Fp1601SR AU<br />
Fastnet probe for Frame Relay. Provides monitoring and statistical<br />
information for Frame Relay Networks. Complete with interface cable and<br />
management software.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
lan/Wan analySerS<br />
Spirent Netcomm Smartbits SMB600 Mainframe<br />
SpI,SMb600 AU<br />
Mainframe for router test system for determining router and network<br />
performance including latency, latency variation and jitter. Can be used to<br />
load network with specific definable traffic to determine routing performance<br />
and discover throughput bottlenecks. Supplied with standard software and<br />
30 version of Smartflow application. Requires appropriate interface cards.<br />
Spirent Smartbits LAN-3101A interface for SMB600/6000<br />
Chassis<br />
SpI,SMb600-3101A AU<br />
Spirent Smartbits LAN-3201B Gigabit card for SMB600/6000<br />
SpI,SMb600-3201b AU<br />
Spirent Smartbits LAN-3310A 2Port Gigabit Card for<br />
SMB600/6000<br />
SpI,SMb600-3310A AU<br />
Spirent Netcomm Smartbits SMB6000 Mainframe<br />
SpI,SMb6000 AU<br />
12 card Mainframe for router test system for determining router and network<br />
performance including latency, latency variation and jitter. Can be used to<br />
load network with specific definable traffic to determine routing performance<br />
and discover throughput bottlenecks. Supplied with standard software<br />
and 30D version of Smartflow application. Requires appropriate interface<br />
cards.<br />
Wan analySerS<br />
HP J2302A 2Mbps WAN Analyser<br />
Hp,J2302A AU/NZ<br />
WAN analyser from 50b/s~2.048Mb/s. Internet Advisor CEpT-E1 and V<br />
series WAN protocol analyser. Includes; RS232/V24, V35, RS449, and<br />
CEpT-E1 analysis to 2Mb/s with bNC connectors. ISDN primary rate<br />
analysis available with Hp,18284A pod. Full monitor and decoding of major<br />
protocols over any channel. Fractional channel or full CEpT-E1. Complete<br />
English decodes with customizable displays, real-time stamp for captured<br />
data or statistics, 100ns resolution. Extensive data-filtering capability.<br />
Real-time statistical analysis, including LAN traffic analysis over WANs.<br />
100% capture performance during full line loading. Simultaneous decodes,<br />
statistics, triggers, and filters. Log to hard disk. Full bit Error Rate tests to<br />
2Mb (including G.821). Over 150 pre-written test included.<br />
HP J2302B 2 Mbps WAN Analyser<br />
Hp,J2302b AU<br />
Internet advisor. WAN analyser from 50b/s~2.048Mb/s. CEpT-E1 and V<br />
series WAN protocol analyser. Includes: RS232/V24, V35, RS449, and<br />
CEpT-E1 analysis to 2Mb/s with bNC connectors. ISDN primary rate<br />
analysis available with Hp,18284A pod. Full monitor and decoding of major<br />
protocols over any channel. Fractional channel or full CEpT-E1. Complete<br />
English decodes with customizable displays. Time stamp for captured data<br />
or statistics, 100ns resolution. Extensive data filtering capability. Real<br />
time statistical including LAN traffic analysis over WANS. 100% capture.<br />
performance during full line loading. Simultaneous decodes statistics,<br />
triggers, and filters. Log to hard drive. Full bit Error Rate tests to 2mb/s<br />
(BERT) including G821. Over 150 prewritten tests included.<br />
DATA, NETWORK & TELECOMMUNICATIONS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 31
DATA, NETWORK & TELECOMMUNICATIONS<br />
32<br />
lan cable teSterS<br />
Fluke DTX1200 Category 6 Cable Certification Tester<br />
FLU,DTx1200 AU/NZ<br />
Cable certification tester. Tests up to 350MHz; Cat6 Autotest time of 12s.<br />
Comes complete with latest cat6 pM-06 peronality modules. Linkware pC<br />
software, and USb cable. Internal memory stores 350 tests. Optional<br />
memory card stores 2,000 tests.<br />
Fluke DTX1800 Category 7 Cable Certification Tester<br />
FLU,DTx1800 AU/NZ<br />
Cable certification tester up to 900MHz; Cat6 Autotest time of 12s. Comes<br />
complete with latest cat 6 pM-06 personality modules, Linkware pC software,<br />
and USb cable. Internal memory stores 350 tests. Tests to Cat 3, 4, 5, 5E,<br />
6 & 7. Included Cat6 heads will test up to category 6. Optional memory card<br />
stores 2,000 tests.<br />
> NEW<br />
Fluke DTX 10 Gig copper Testing and Certification Kit<br />
FLU,DTx-10G KIT AU<br />
Used in conjunction with the FLU,DTx1800. Enables testing and certification<br />
of twisted pair cabling for 10 Gigabit Ethernet deployments - whether it is an<br />
existing Cat 6 or newly installed augmented Cat 6 cabling system. Measures<br />
the performance for 10 Gig and Alien Crosstalk (ANExT and AFExT) in full<br />
compliance with the industry standards to 500 MHz.<br />
Fluke DTX-MFM Multimode Fibre Adaptor for DTX Cable<br />
Analyser<br />
FLU,DTx-MFM AU<br />
DTx1200/1800 multimode fibre interface. Tests fibre installations in local<br />
area networks. Fits in the slot on the back of DTx cable analyser (standard<br />
copper cable adaptors can be connected but not used simultaneously).<br />
provides fibre testing and certification. bi-directional testing at 850nm<br />
& 1300nm at the same time. Measures optical power loss, length, and<br />
propagation delay for multimode fibres. pass/fail results based on common<br />
fibre standards. SC optical connectors. Includes in built visual fault locater.<br />
(VFL)<br />
Fluke DTX-SFM Singlemode Fibre Adapter for DTX Cable<br />
Analyser<br />
FLU,DTx-SFM AU<br />
DTx1200/1800 singlemode fibre interface. Use for testing fibre installations<br />
in local area networks. Fits in the slot on the back of DTx cable analyser<br />
(standard copper cable adaptors can be connected but not used<br />
simultaneously). provides fibre testing and certification. bi-directional<br />
testing at 1310 nm and 1550 nm at the same time. Measures optical power<br />
loss, length, and propagation delay for multimode fibres. pass/fail results<br />
based on common fibre standards. SC optical connectors. Includes in built<br />
visual fault locater. (VFL)<br />
Fluke DSP Personality Module for DSP4X00 series<br />
FLU,DSp-pM AU<br />
personality module for Fluke DSp4x00 cat6 permanent Link heads. RJ45<br />
connector sets (pM-01, pM-06, pM-25) include 2 modules. block connector<br />
sets include one module (pM-12b, pM-13b). Modules available include pM-<br />
06 (most systems), pM-25 (most unshielded systems), pM-01 (legacy), pM-<br />
12b paduit GIGA-pUNCH 110 block, pM-13b Siemon S210 block.<br />
Fluke Networks CableIQ Cable & Network Identification Tool<br />
FLU,CAbLEIQ<br />
CableIQ cable and network tester for twisted-pair, coax, and audio cabling.<br />
Allows troubleshooting connectivity problems and qualify cabling bandwidth<br />
to see whether an existing cabling link is qualified to support 10/100, VoIp<br />
or Gigabit Ethernet. Discovers what is at the far end of any network cable.<br />
Detects speed and duplex settings of attached switches and PCs. Intelligent<br />
wiremap graphically shows distance to faults (e.g., pin 1 break at 31m). Can<br />
also test cable set-up for audio application (intercom/pA). Hand held and<br />
lightweight, powered by 4 x AA Alkaline batteries. Can be used as a signal<br />
source for optional Intellitone cable tracer.
NEW<br />
Fiber Video Display Scope<br />
FLU,FT330 AU<br />
Handheld battery operated video scope for fiber inspection.<br />
> NEW<br />
Fiber Inspection Video Probe X 250 Magnification<br />
FLU,FT350 AU<br />
Connects to a FLU,OpTIFIbER or FLU,FT330 to let you inspect the ends of<br />
fiber optic connectors. 250 x magnification reveals dirt, scratches, and other<br />
defects that can cause poor performance or failures in fiber optic networks.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
fibre OpticS<br />
> NEW<br />
Fiber Inspection Video Probe X 250 & 400 Magnification<br />
FLU,FT650 AU<br />
Fibre probe for use with Fluke Optifiber OTDR or FLU,FT330 handheld video<br />
scope. Has switchable 250 and 400 times magnification.<br />
Fluke FTK200 Optical Fibre Power Meter/Light Source<br />
FLU,FTK200 AU<br />
Comprises light source and power meter. Light source is multi-mode 850nm<br />
& 1300nm (-20dbm into 62.5µm fibre). Stability is ±0.1db per 8h at 25 0 C.<br />
power meter has calibrated measurements at 850/1300nm multi-mode &<br />
1310/1550nm single-mode. 6dbm~-50dbm measurement power with 0.01<br />
resolution & accuracy of ±0.25 at 25 0 C & -10dbm. power meter memory<br />
stores up to 500 results at each wavelength which can be downloaded to PC<br />
with supplied software (also compatible with Fluke Cable Manager used for<br />
the DSp4000/4100 series). ST connector on power meter and light source.<br />
DATA, NETWORK & TELECOMMUNICATIONS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 33
DATA, NETWORK & TELECOMMUNICATIONS<br />
34<br />
fibre OpticS<br />
Fluke Optifibre Multi-mode OTDR<br />
FLU,OpTIFIbER-MM AU<br />
Short range multimode OTDR designed for testing, troubleshooting and<br />
certifying network cabling. 850/1,300nm, 62.5mm (100m launch cable<br />
included) & 50mm (requires launch cable) fibres with SC connectors.<br />
Attenuation deadzone 850nm: 4.5m typical, 5.5m max 1,300nm: 10.5m<br />
typical, 15m max. 3km range for 850nm & 7km range for 1,300nm. Measures<br />
insertion loss and fibre length, allows automatic and manual OTDR analysis<br />
including channel map of connectors. Included LinkWare pC software<br />
documents, reports and manages all test data. Battery operated with colour<br />
display.<br />
Acterna OMK-6 Fibre Optic Power Meter<br />
WG,OMK-6 AU/NZ<br />
OMK-6 optical power meter with multi mode and single mode light sources.<br />
Level measurement is -65~+10dbm. Measurement errors are eliminated<br />
because the power meter automatically detects the wavelength being<br />
transmitted by the light source. Single mode dynamic range with continuous<br />
wave is 58db (approx 145km @ 1310nm & 230km @ 1550nm). Multi mode<br />
dynamic range with continuous wave is 40db (approx 20km at 850nm &<br />
50km at 1310nm).<br />
Acterna OMK-14 Optical Measurement Kit<br />
WG,OMK14 MY<br />
Kit consists of WG,OLS-15 (light source) and WG,OLp-15 (power meter).<br />
WG,OLS-15; 1310nm & 1550nm, o/p; 7dbm (into 9/125µm) mod frequency:<br />
270Hz, 1kHz, 2kHz. WG,OLp-15; 800~1700nm, switchable at; 850, 980,<br />
1310, 1480 & 1550nm. Sensor type InGaAs, suitable fiber type 9/125a~50/<br />
125µm. Mod detection; 270Hz, 330Hz, 1KHz, 2KHz. Display range -<br />
70~11dbm.<br />
Kingfisher Optical Attenuator<br />
KIN,KI7010 AU/MY<br />
1310/1550nm single-mode including 2 interchangeable pC connector<br />
interfaces, and adaptors. Attenuation range 60db, resolution 0.05, power<br />
capability +20dBm and linearity 0.02dB. Operational modes include manual,<br />
relative, step and programme control.<br />
Kingfisher KI 6000/8000 Optical Power Meter and Source<br />
KIN,KI6000/8000 AU<br />
Light source (KI8000) and power meter (KI6000) optical fibre test set for<br />
multimode applications 1300nm & 850nm. Units have ST connectors and<br />
a variety of patch leads. Light source modules 812 & 809 fitted to KI8000.<br />
KI6000 power meter uses a germanium detector for broadband operation.<br />
power meter can be used for single-mode applications but requires a<br />
seperate single-mode light source such as the KIN,KI8022.<br />
Nettest 6250/6025 Light Source/Power Meter 1310/1550<br />
GNE,6250/6025 AU<br />
Single-mode light source (6250) and power meter (6025) combination. Light<br />
source is 1310nm/1550nm, -8 dbm min power output laser output. power<br />
meter and light source autoswitch wavelengths to synchronize with each<br />
other. Stores past 2 results in memory for reference. Comes in hard case.<br />
Battery operated<br />
Nettest FI720 Active Fibre Detector<br />
GNE,FI720 AU<br />
Non intrusive fibre tool for identifying active fibres. Measures bare fibres,<br />
coated fibres, and jacketed patch cords. Gives readout of optical power level<br />
in fibre and can detect optical test tones of 270Hz, 1, & 2kHz. Measures<br />
wavelengths 800~1700nm and power levels from 0~-40dbm (±2). Insertion<br />
loss NEW<br />
Nettest CMA 5000 Singlemode 43/45dB OTDR<br />
GNE,CMA5000SM-45 AU<br />
Single mode OTDR with SC/ApC (angled) adaptor. 1310/1550/1625 dynamic<br />
range 43/45/43db. +20dbm meter and light source, and VFL (Visual Fault<br />
Locator). OTDR has built in CD-R/W and 20Gb hard drive. Dedicated touch<br />
screen and hard key user interfaces. Mains and battery operation, battery<br />
life >3h. 10/100Mb Ethernet port for network connectivity. USb ports.<br />
Nettest CMA4000 Single/Multi Mode OTDR<br />
GNE,CMA4000MMSM AU<br />
Includes mainframe and 850/1300nm (25/24db) multimode and 1310/1550nm<br />
(30/30db) single-mode module (module Model 4457). Instrument has built<br />
in FDD and supplied with SC/pC, FC/pC, and ST/pC connectors.<br />
Nettest CMA4000 Single/Multi mode OTDR<br />
GNE,CMA4000MM AU<br />
Single mode and multi mode OTDR. Includes mainframe and 850/1300<br />
nm (25/24 db) multimode and 1310/1550 (30/30 db) single mode module<br />
(module Model 4457). This instrument has built in 3.5 disc drive and is<br />
supplied with SC/pC, FC/pC, and ST/pC connectors.<br />
Nettest CMA4000 Single Mode OTDR<br />
GNE,CMA4000SM AU<br />
Includes mainframe and 1310/1550nm (34/36db) single-mode module<br />
(module part number TD-14M25003 Model 4425). Instrument has built in<br />
FDD and supplied with SC/pC, FC/pC, and ST/pC connectors.<br />
Nettest CMA4000 1310/1550nm (40dB) Single Mode Module<br />
GNE,TD-14M36003 AU<br />
For the GN Nettest CMA4000 OTDR mainframe. Module has SC/pC &<br />
FC/pC connectors. Operating wavelengths are 1,310nm (40db) & 1,550nm<br />
(40db).
NEW<br />
Yamasaki Y16 Fibre Cleaver<br />
YAM,Y16 AU<br />
Precision fibre cleaver. This cleaver can be used with precision splicers for<br />
single and multi mode fibres.<br />
> NEW<br />
Yamasaki Y80 Core Alignment Fusion Splicer<br />
YAM,Y80 AU<br />
Precision core alignment single and multi mode fusion splicer. Instrument<br />
is fully automatic or manual and provides a typical splice loss of 0.02 dB<br />
on single mode fibre, and 0.01 dB on multi mode fibre. The instrument has<br />
automatic environment sensors, operates from -10C to 50C, 95% humidity<br />
and operates up to 4000m. Includes a built-in heater for applying splice<br />
protectors and a splice tension tester. Front mounted colour display and can<br />
be operated from AC (176-264V, 47-63Hz), or battery.<br />
> NEW<br />
Fitel S325A Precision Fibre Cleaver<br />
FIT,S325A AU<br />
Can be used with precision splicers for single and multi mode fibres.<br />
Features a built in sharps collection bin which automatically stores fibre<br />
offcuts as each fibre is cleaved.<br />
> NEW<br />
Fitel S177A Core Alignment Fusion Splicer<br />
FIT,S177A AU<br />
Precision core alignment single and multi mode fusion splicer. Fully<br />
automatic and provides a typical splice loss of 0.02dB on single mode and<br />
0.01db on multi mode. Splice time 9sec. Temperature range -10~50ºC,<br />
humidity range up to 90% at 38ºC, and altitude sensors operate up to 4000m<br />
which adjust arc time and intensity as required. Includes a built-in heater for<br />
applying splice protectors and a splice tension tester (200g). Front mounted<br />
colour display. AC mains operation 100~240V, or battery (up to 70 splices).<br />
Excludes cleaver which must be rented separately.<br />
Fitel S323B Fibre Cleaver<br />
FIT,S323b AUNZ<br />
Use with precision splicers for single and multi mode fibres. built in sharps<br />
collection bin automatically stores fibre offcuts as each fibre is cleaved.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
fibre OpticS<br />
Fitel S121A V-Groove Fusion Splicer<br />
FIT,S121A AU<br />
Splice loss is 0.1dB for single mode & 0.05dB multi mode. Splice time is 13s.<br />
Includes splice protector heat shrink heater and splice tension tester (200g).<br />
Operates from ac (100~240V) or battery (up to 30 splices & heatings per<br />
charge). Cleaver excluded.<br />
Fitel S175 Core Alignment Single & Multi Mode Fusion Splicer<br />
FIT,S175 AU<br />
Default multi-mode operation is cladding align. Fully automatic. provides<br />
typical splice loss of 0.02db on single-mode & 0.01db on multi-mode.<br />
Temperature, humidity & altitude sensors adjust arc time & intensity. Includes<br />
built-in heater for applying splice protectors. Cleaver excluded.<br />
Fitel S176CF Core Alignment Single & Multi Mode Fusion<br />
Splicer<br />
FIT,S176 AU<br />
Fully automatic. Typical splice loss of 0.02db on single-mode & 0.01db on<br />
multi-mode. Splice time 13s. Temperature range -10~500C, humidity range<br />
up to 90%RH at 380C & altitude sensors (operates up to 3,658m) adjust arc<br />
time & intensity. Includes heater for applying splice protectors and splice<br />
tension tester (200g). Front mounted colour display. AC mains operation<br />
100~240V, or battery (up to 60 splices & heat shrinks per charge). Cleaver<br />
excluded.<br />
300M Multimode Fibre Optic Launch Cable<br />
FIb,MULTI/300M<br />
Multimode fibre test cable. 300 metres.<br />
Anritsu MG921A 1300nm Stabilised Light Source<br />
AU<br />
ANR,MG921A MY<br />
Use with multi-mode/single-mode fibre of 1.3µm wavelengths.<br />
Unprecedented light o/p level & wavelength stability through use of ApC<br />
& temperature control ccts. Internal & external modulation functions are<br />
provided, permitting removal of stray light.<br />
Nettest TD-4791-CL DWDM Optical Spectrum Analyser Module<br />
GNE,OSA-TD4791CL AU<br />
For dense wavelength division multiplexing applications. Can be used over<br />
optical fibre C (1,530nm~1,570nm) & L bands (1,570nm~1,628nm). Use<br />
with CMA-4000 mainframe. Resolution to 10GHz. For all WDM applications<br />
including high density of 80 channels and above.<br />
Nettest Nexus Polarisation Mode Dispersion Analyser<br />
GNE,pMD AU<br />
For optical C-band measurements. 55db dynamic range. For measurements<br />
on optical fibre for qualification for DWDM or analogue video applications.<br />
Noyes OFS300 Fibre Optic Cable Microscope<br />
NOT,OFS300 AU<br />
DATA, NETWORK & TELECOMMUNICATIONS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 35
CABLE/PIPE TESTERS & LOCATORS<br />
36<br />
cable/pipe teSterS & lOcatOrS<br />
> NEW<br />
Fluke IntelliTone Pro 200 Kit<br />
FLU,INTELLITONEpRO AU<br />
Locate, isolate, and validate twisted pair (UTp, Cat 5e, Cat 6), coax cables<br />
(RG6, RG59, and others for CATV/CCTV), bare wire (such as speaker wire<br />
and security network wire), and Cat 3 telephone cabling. The toner also lets<br />
you validate voice and data services.<br />
Tempo TE-508S Cable Locator<br />
TEM,508S AU/NZ<br />
Tempo 508S Cable Locator for locating buried or in-wall wiring. Compact<br />
design. Provides results on buried cables to depths of 1 meter and lengths<br />
up to 300 meters. Can be used to determine approximate depth of a wire or<br />
cable before you dig. Fully adjustable transmitter output and receiver gain<br />
Transmitter frequency is 447.5KHz. Transmitter can be connected directly to<br />
AC power outlet. Transmitter runs approximately 35 hrs and receiver runs<br />
approximately 20 hrs from standard 9V batteries.<br />
Pathfinder PF610 Circuit Tracer Kit<br />
pAT,pF610 AU<br />
For tracing concealed power cabling and other signal or data conductors.<br />
Comprises a transmitter and a detector. Transmitter when connected to a<br />
cable generates a 4.6kHz current pulse by drawing low current from the<br />
cable circuit. In the case of data and signal circuits a 9V battery can be used<br />
to power the cable. This may require disconnection of computer equipment,<br />
etc. Detector gives audible and visual indication of the signal field. Trace 1<br />
& 3 phase cables, coax, buried unpowered cable, locate fuses, etc.<br />
Pathfinder 220 Cable Locator/Tracer<br />
pAT,LOCAT220 AU<br />
For tracing live power cables within buildings. Connection is generally made<br />
at an outlet. Transmitter has visual and audible indication. Range 3m.<br />
Haganuk Teleflex 2000 Cable Fault Tester<br />
HAG,2000 AU<br />
Time domain reflectometer for power cables. Measuring ranges : 250, 500,<br />
1,000, 2,500, 5,000, 10,000, 25,000 & 50,000ft. pulse widths: 10, 100, 200,<br />
1,000, 2,000 & 10,000ns. Accuracy: ±1% typical,
Tektronix 1503C TDR Cable Tester<br />
TEK,1503C AU/NZ/MY<br />
Distance range 50,000’, resolution 0.04’ & 50, 75, 93, 125Ω output<br />
impedance. LCD display. Internal battery or mains operation. Supplied with<br />
ethernet testing and isolation network options.<br />
Tektronix 1503 Time Domain Reflectometer<br />
TEK,1503 MY<br />
Time Domain Reflectometer for long cable fault location. Display from<br />
0~5,000 to 0~50,000 feet. Internal battery or mains operation.<br />
Tasco P<strong>TR</strong>600 Cable Tracer<br />
TAS,p<strong>TR</strong>600 NZ<br />
Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2<br />
clamp CTs without disconnecting the earth conductor. Measures the dc loop<br />
resistance without any influence from other conductors.<br />
Radiodetection RD4000 Type 7 Cable Location Kit<br />
RAD,RD4000TYpE7KIT AU<br />
Includes transmitter and locator. Receiver has 640Hz, 8, 33 & 82kHz, 2<br />
power and radio modes. 3 locating modes. Modes, 2 peak, 1 null, location<br />
arrows, simultaneous digital depth and current readout. Transmitter T10<br />
version, FF, 640Hz, 8, 33 & 82kHz transmission freq. LCD display for freq,<br />
power, battery and connection readout, multimeter function, cable fault<br />
find function, 10W output, high efficiency induction mode. Signal clamp<br />
100mmØ. Connection leads and carry bag.<br />
Radiodetection A Frame for RAD,RD4000 Type 7 Kit<br />
RAD,AFRAME FORRD4000 AU<br />
A-Frame accessory for RAD,RD4000Type7KIT. For sheath to ground type<br />
fault finding.<br />
Radiodetection Flexisonde Pipe Tracer<br />
RAD,FLExISONDE AU<br />
Sonde for use with RD400pxL. Flexible rod on reel 50m long complete<br />
with 2 sondes. Small sonde transmitter is suitable for insertion into plastic<br />
pipes of 25mmØ & 150mm min bend radius. Can be detected at depths<br />
up to 1.5m. Larger sonde can be detected at 5m depth and is suitable for<br />
insertion into plastic pipes of 80mmØ & 210mm min bend radius. Sondes<br />
are battery operated.<br />
Radiodetection Supersonde<br />
RAD,SUpERSONDE AU<br />
Can be connected to the RAD,FLExISONDE cable if required. Detectable<br />
to 15m depth.<br />
Radiodetection 100mm Clamp Antenna<br />
RAD,CLAMp-ANT AU<br />
For use with RAD,RD400pxL. Identify an individual cable out of a bunch.<br />
Good for cable tracing. Transmitter is connected to one end and placed<br />
around individual cables for identification. Clamp is 100mmØ.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
cable/pipe teSterS & lOcatOrS<br />
Radiodetection RD400PXL Pipe and Cable Locator<br />
RAD,RD400pxL AU<br />
Can measure current in buried lines. Includes transmitter and locator, peak<br />
and null location by audio and meter, very useful in congested areas. Has<br />
power /radio/8kHz/33kHz modes, can read depth to 3m. Includes direct<br />
connect lead and signal clamp (tong) (10cm). Works with optional sondes to<br />
trace sewers and plastic pipes.<br />
> NEW<br />
CScope CATXDSGV-KIT Cable and Pipe Locator<br />
CSC,CATxDSGV-KIT AU/NZ<br />
Cable location tool. Includes 33kHz generator with touch button controls<br />
and LCD, xD receiver/ locator with 33kHz, power or radio modes. Direct<br />
connection cable, stake and 75mm tong set. The transmitter can operate<br />
with direct connection, tongs or induction. The instrument will also determine<br />
cable depth, range 0.2m to 3m . It will operate with the Radiodetection<br />
33kHz sondes.<br />
ICC LD400 Ultrasound Leak and Emission Detector<br />
ICC,LD400 AU<br />
Used to detect water and gas leaks, from ultrasonic emission. Also used for<br />
mechanical noise location. Supplied complete with an ultrasonic transmitter<br />
to enable leaks within containers to be detected, e.g. vehicle bodies, fuel<br />
tanks. Aural and visual indication. battery operated.<br />
ICC LD408 Noise Leak Detector<br />
ICC,LD408 MY<br />
Used to detect water & gas leaks, etc. from ultrasonic emission. Also may<br />
be used for mechanical noise location. Supplied complete with an ultrasonic<br />
transmitter to enable leaks within containers to be detected, e.g. vehicle<br />
bodies, fuel tanks. Aural & visual indication. battery operated.<br />
Ultra Probe UP100KT Ultrasonic Leakage Detector<br />
ULT,Up100KT AU/NZ<br />
Hand held pistol type with stainless steel sensor enclosure. Frequency<br />
reponse 20~100kHz, (centred at 28 ~42kHz), 10 segment LED bargraph<br />
(red). Sensitivity 8 precision attenuation. Response time 300ms, operating<br />
temperature range 0~500C. Kit includes contact stethoscope module with<br />
different wave guide extension rods for direct for use on pipes, bearing<br />
housings, steam traps, etc. Rubber focusing probes, head set, warble tone<br />
generator for determining leaks in seals of empty containers, etc.<br />
Primayer Omikron Water Leak Detector<br />
pRI,OMIKRON-AG AU<br />
Water leak locating listening probe and ground microphone system designed<br />
to locate leaks in water pipe. Supplied with headphones and interconnection<br />
cables. probe detects leak noise directly at available valves hydrants, etc.<br />
High sensitivity and wide band amplification of leak noise particularly at lower<br />
frequencies. Microphone will detect noise reaching the ground surface.<br />
CABLE/PIPE TESTERS & LOCATORS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 37
ELEC<strong>TR</strong>ICAL POWER
ELEC<strong>TR</strong>ICAL POWER<br />
40<br />
magnetic field meterS - gauSS teSla<br />
Model Type Frequency (Hz) Range (G) Electric Field Output<br />
ARL,GM AC magnetic field meter 12~1,300 9.9 ~ 99mG CRO<br />
HOL,HI-3627 Vector AC magnetic field meter 5~2,000 0.2 ~ 20<br />
HOL, HI-3604 AC field strength meter 50~100 0.1 ~ 20,000mG 1~200,000V/meter<br />
TES,70 AC magnetic field meter 30~600 0.1 ~ 1,999mG<br />
HMI,GM04<br />
bEL,4080 Digital gauss meter<br />
40~600 0.1mG ~ 511mG<br />
> NEW<br />
Bell 5180 Gauss/Tesla Meter<br />
bEL,5180 AU<br />
Magnetic measuring equipment, portable gaussmeter. built-in software<br />
eliminates the need for complex calibration procedures. Key features<br />
include Auto Zero, Min./Max./peak Hold, Auto Range and Relative Mode.<br />
Allows the user to select Gauss, Tesla or Ampere/Meter readings. With<br />
Hall effect transverse probe. Frequency bandwidth DC~30kHz, range up to<br />
30kG. Analogue output (±3V FS) and USb interface. battery operated.<br />
Arlyuna LF Milligauss Magnetic Field Strength Meter<br />
ARL,GM NZ<br />
Handheld ac magnetic field strength meter. Ranges 9.9mG & 99mG.<br />
Measurement bandwidth 12Hz~1.3KHz. 60Hz & 50Hz filter and analogue<br />
ac output for connection to oscilloscopes, recorders or loggers.<br />
Bell 4048 ac/dc Gauss Meter<br />
bEL,4048 NZ<br />
Handheld digital ac/dc Gauss/Tesla meter. Ranges are 200~20kGauss with<br />
a resolution of 0.1Gauss or 0.02~2Tesla with a resolution of 10E-6Tesla.<br />
Accuracy is 2% +2 digits. peak hold feature. Supplied with transverse probe<br />
and zero gauss chamber.<br />
Bell 4080 ELF Gaussmeter<br />
bEL,4080 AU<br />
Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging<br />
0.1~511mG. probe: 3 axis technology, maintains accuracy regardless of<br />
orientation. True rms measurement. Typical accuracy error: ±2%, +1 digit.<br />
Frequency response: ±5% 40~600Hz, -3db 25/1,000Hz. Applications<br />
include detecting magnetic field emissions from overhead ac power lines,<br />
video display terminals, office equipment and household appliances. This<br />
unit is not suitable for measuring field strength of “neodymium” or “rare earth”<br />
magnets or any permanent magnets. The frequency response ± 5% 40-<br />
600Hz and -3db 25/1000Hz.<br />
Bell 5080 Gauss/Tesla Meter<br />
bEL,5080 AU<br />
Portable gaussmeter complete with Hall effect transverse probe. Frequency<br />
bandwidth dc - 20kHz, ranges 300G~30kG. Max resolution 0.1G (10µT). Max<br />
and min hold. Analogue output and RS232 interface. battery operated.<br />
dc~10kHz 30 ~ 30,000<br />
bEL,4048 dc~12 200 ~ 20,000<br />
BEL,5080 dc~20kHz 300 ~ 30,000 Analog & RS232<br />
BEL,5180 dc~20kHz 300 ~ 30,000 Analog & USb port<br />
bEL,4090-20 Digital ELF gauss meter 40~400 0.1 ~ 1999mG<br />
Holaday HI-3627 Magnetic Field Meter<br />
HOL,HI-3627 AU<br />
Three orthogonal field sensors. Dynamic range 0.2mG~20G. True rms<br />
detection. Frequency range 5Hz~2kHz with an in-built 30Hz high pass filter.<br />
Meets requirements of the Swedish protocol and the IEEE p-1140 protocol.<br />
Holaday HI-3604 LF E & H Field Monitor<br />
HOL,HI-3604 AU/MY<br />
Low frequency field meter. Designed to evaluate electric and magnetic fields<br />
associated with 50Hz power lines. Frequency range 30~2,000Hz. Measures<br />
magnetic fields from 0.1 milligauss to 20 gauss. Measures electric fields from<br />
1 volt/meter to 200 kilovolts/meter. LCD display. 127 reading data memory.<br />
Meets the interim requirements of the Australian Radiation Laboratory for<br />
normal levels of AC power exposure.<br />
Hirst GM04 Microprocessor Controlled Gaussmeter<br />
HMI,GM04 AU<br />
Facilities: store and recall on 0~99 samples, hold. Analogue peak with<br />
digital storage. Auto and manual ranges. Automatic reading conversion<br />
between different units. (Note 1mT = 10G)<br />
Range 1: 0~to more than 3T resolution 1mT.<br />
Range 2: 0~299.9mT resolution 100µT.<br />
Range 3: 0~29.99mT resolution 10µT.<br />
Range 4: 0~2.999mT resolution 2µT.<br />
Accuracy (at 200C): ± 1%. Frequency range: dc and 15Hz~10kHz.<br />
Functions: dc, dc peak, ac rms, ac rms max, & ac peak. Applications include<br />
measurement of magnetic flux density of magnets and assemblies, electric<br />
motor air gaps and drive actuators.<br />
Hirst Magnetic Instruments GM04 Axial Probe<br />
HMI,GMO4AxIAL pRObE AU<br />
Axial probe for use with HMI,GM04.<br />
Teslatronics 70 milliGauss Meter<br />
TES,70 NZ<br />
Tri-axial ac magnetic field meter. Range is 0.1~1,999mGauss, accuracy is<br />
±1% at 60Hz. Frequency response is 40~400Hz ±10%, 50~300Hz ±5%,<br />
30~600Hz - 3db.<br />
Tri-axial Milligauss Magnetic Field Meter<br />
bEL,4090-20 NZ<br />
Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging,<br />
0.1~1999mG. Resolution 0.1mG in high-sensitivity mode & 1mG resolution<br />
in low-sensitivity mode. probe 3 axis technology, maintains accuracy<br />
regardless of orientation. True rms measurement. Typical accuracy error:<br />
±1% + 1 digit. Frequency response: ±10% 40~400Hz, -3db, 20/2000Hz.<br />
Applications include detecting magnetic field emissions from overhead<br />
ac power lines, video display terminals, office equipment and household<br />
appliances.
Model Type<br />
SEW,x3760pKIT+<br />
SEW,EUROpA pAT<br />
portable Appliance Tester<br />
Voltage<br />
V<br />
Resistance<br />
Ω<br />
Current<br />
A<br />
MEG,CBT2 RCD Tester 6~500mA<br />
MEG,LT6 Earth Loop Impedance 20~2kΩ<br />
Frequency<br />
Hz<br />
Features<br />
AS3760:2001 Compliant, full<br />
keyboard, barcode scanner,<br />
RS232, Automatic label/tag<br />
printer<br />
AS3760:2001 Compliant, barcode<br />
scanner, RS232<br />
LEM,SATURN GEO<br />
EASY<br />
0~20kΩ 50mA 128 Battery,RS232<br />
LEM,SATURN GEO x<br />
Soil Resistivity Tester<br />
48ac<br />
1mΩ~300kΩ 250mA 94~128<br />
battery, Stakeless measurement,<br />
earth loop impedance,RS232<br />
MEG,DET5/3R 0.1~19,999 128 Battery<br />
MEG,DET20C Earth Resistance Clamp 25mΩ~1550Ω 0.2~35 battery, USb output of data<br />
MEG,BM21<br />
MEG,BM11D<br />
25~5000 5TΩ 2mA/kV<br />
500,1kV, 2.5kV,<br />
5kV<br />
10kΩ~500GΩ<br />
MEG,10-01-10KV 10kV 1TΩ 99µA<br />
MEG,1020-10KV DIT<br />
Insulation Tester<br />
50~5000 35TΩ<br />
dc<br />
Operates from main supply or<br />
battery<br />
LEM,SATURNISO 50 ~ 1,000 30GΩ Battery<br />
HIO,3455HVIT,5KV<br />
250, 500, 1kV,<br />
2.5kV, 5kVdc<br />
5TΩ 1mA<br />
HIO,3454-51-3 250, 500, 1000 4GΩ 200mA<br />
HVD,HVA30-DC/VLF High Voltage Insulation<br />
DielectricsTest Set<br />
33kV, 5µF 190hm 15mA<br />
HVD,HVA60-DC/VLF 60kV, 50mA<br />
CHK,LM05<br />
1µΩ~20Ω 10<br />
dc/VLF<br />
Battery<br />
Operates from main supply or<br />
rechargeable battery<br />
battery, data storage & USb<br />
interface<br />
Insulation with 200mA continuity<br />
tester<br />
Four in one HV test set<br />
VLF/DC/Jacket Sheath/Fault<br />
Conditioning<br />
CRO,D07 600µΩ~60Ω 10 c/w probe/Lead Set<br />
T&R,DSM600 67µΩ~6.6mΩ 600<br />
T&R,DSM200 200µΩ~4Ω 200/10<br />
VAL,4300b<br />
Micro-Ohm Meter<br />
2µΩ~20kΩ 100mA~10<br />
dc<br />
Heavy duty Kelvin leads<br />
MEG,DLRO10<br />
MEG,DLRO1-10x<br />
0.1mΩ~2kΩ 10<br />
Alpha-numeric keypad for<br />
entering test notes, autoranging<br />
with manual option, realtime or<br />
MEG,DLRO200<br />
0.1µΩ~999.9mΩ<br />
10~200<br />
from storage via RS232, large<br />
backlit LCD<br />
MEG,DLRO600 10~600 RS232, Software<br />
MEG,CM500<br />
0~250mA 16~460 RS232, Software, RCD tester,<br />
MEG,MFT1502<br />
Multifunction Installation<br />
Tester<br />
280~1kV<br />
0.01~499MΩ<br />
0~200mA 45~65<br />
Loop impedance, Prospective<br />
short circuit<br />
LEM,SATURN100+ 1~400 0.01~9.99kΩ 0~1 15.3~457 Battery<br />
bAU,DpA75<br />
0~ 75kV rms RS232<br />
Oil Insulation Tester<br />
AVO,OTS60pb 60kV rms Battery, RS232<br />
bJM,ALL-TEST3 Motor, Coil Tester 1 kV 0~20MΩ 100~2,400 Power Factor, Capacitance<br />
3M,701 Megohm Meter 10 ~ 100 0~10GΩ ESD Surface Testing<br />
MEG,MIT1020-10KV DIT Insulation Resistance 1kV~10kV 10kΩ~35TΩ USb, RS232, battery<br />
MEG,RCDT330 Residual Current Device 0~300 10mA~1kmA 25~450 USb, battery, Ip54<br />
See Also Hi-pot Testers<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
inSulatiOn/cOnditiOn/reSiStance teSterS<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Battery<br />
RS232<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 41
ELEC<strong>TR</strong>ICAL POWER<br />
42<br />
inSulatiOn/cOnditiOn/reSiStance teSterS<br />
> NEW Megger MIT1020 Diagnostic 10kV Insulation<br />
Resistance Tester<br />
MEG,MIT1020-10KV DIT AU<br />
backlit display, variable test voltage from 50~5000V, Automatic IR, pI, DAR,<br />
SV and DD tests, measures to 35TΩ, RS232 & USb download of results.<br />
IEEE 43-2000 recommends the use of 10kV for motor windings rated above<br />
12kV. protection rating of Ip54. Mains or battery powered.<br />
Megger 10-01 10kV Insulation Tester, Test Voltage 500~10,000V<br />
MEG,10-01-10KV AU<br />
The Megger MEG,10-01-10kV Insulation Tester is a compact, Microprocessor<br />
controlled high voltage dc Insulation tester.<br />
> NEW HV Diagnostics 30kV-15mA DC/VLF High Voltage<br />
Insulation DielectricsTest Set<br />
HVD,HVA30-DC/VLF AU/NZ<br />
VLF (0.1Hz), DC (±), cable fault conditioning (burning), and sheath/jacket<br />
testing modes all included. 0.1Hz & 0.02Hz. For solid dielectric cables<br />
such as xLpE and EpR. Fully automatic or manual cable test sequences<br />
complying with International Standards/Guides such as IEEE 400.2, VDE<br />
0296, CENELEC, etc. True symmetrical sinusoidal, load independent,<br />
output waveform across the full load range. Real-time display of actual<br />
output waveform. Easy to use, menu guided, large backlit user interface.<br />
Large output load capability (up to 5µF). Automatic and integrated load<br />
capacitance measurement with optimum frequency selection. Storage of test<br />
results for later retrieval or download to laptop. Short circuited protected.<br />
> NEW HV Diagnostics 60kV-50mA DC/VLF High Voltage<br />
Insulation Dielectrics Test Set<br />
HVD,HVA60-DC/VLF AU<br />
True sine wave low frequency output. 0.1Hz & 0.02HZ. For VLF, DC and<br />
jacket/sheath testing. Fault conditioning capability. Test result storage<br />
capability. Short circuit protection. Complies with CENELEC, IEEE 400.2,<br />
VDE 0296 and other international standards. Manual or fully automatic test<br />
sequence selection. Real-time display of actual output waveform. High<br />
voltage power source suitable for testing electrical plant including cables:<br />
xLpE, pE, EpR, pILC etc, capacitors, switchgear, transformers, rotating<br />
machines, insulators and bushings.<br />
Hioki 3455 High Voltage Insulation Tester<br />
HIO,3455HVIT-5KV AU<br />
pI and DAR function to check insulation quality and step voltage test to detect<br />
for signs of deterioration. Generates a wide range of test voltages, from<br />
250V to 5kV. The voltage may be chosen from the commonly used presets<br />
of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or<br />
decrements of 25V or 100V. Insulation diagnoses for automatic calculation<br />
and indication of pI (polarisation index) and DAR (Dielectric absorption ratio),<br />
step voltage testing and temperature correction. Large memory stores up to<br />
100 manual records and a logging function for 10 data (360 times). Stored<br />
data may be displayed on the LCD or down-loaded to a pC. The date and<br />
time of measurement also recorded.<br />
CHK LM05 Micro-Ohm Meter 10A<br />
CHK,LM05 AU/MY<br />
Operates from internal batteries or external power supply. Max test current<br />
10A. Resistance range up to 20Ω with a max sensitivity of 1µΩ. Includes<br />
power supply-charger, duplex helical test leads, length 2m.<br />
Megger DLRO10 Micro-Ohm Meter<br />
MEG,DLRO10 AU<br />
Self contained automatic micro-ohm meter, selecting the most suitable test<br />
current, up to 10A dc to measure resistance from 0.1mΩ~2kΩ on one of<br />
seven ranges. Instrument is built into a strong, lightweight case that is<br />
equally at home in the field or in the laboratory. Light enough to be worn<br />
around the neck, small enough to be taken into areas which were previously<br />
too small to access. DLRO10 uses a large, bright 4½ digit LED display.<br />
Resolution: 0.1µΩ. battery: rechargeable NiMH, typical life 1,000 test at<br />
full load.
Hioki Digital MΩ HiTester Insulation Tester<br />
HIO,3454-51-3 AU<br />
Continuity function with 200mA and 3 range voltage selectable 250V, 500V<br />
& 1kV. Easy to read digital display, auto-discharge, live-wire warning, safety<br />
system for high voltage measurement, sliding cover. back-lighting liquid<br />
crystal display for easy reading in dark areas, checks ground wire continuity<br />
with a short circuit current of 200mA. Capable of testing the continuity of<br />
electrical facility grounds in accordance with IEC 60364. Measurement<br />
range insulation resistance maximum 4000MΩ @ 1kV. Other functions:-<br />
insulation and low resistance mode - comparator, measurement value hod,<br />
insulation resistance mode - auto discharge, insulation and ac voltage mode -<br />
live wire warning (when voltage of 70V+ or -10V exists across measurement<br />
terminals). Low resistance mode - zero adjust. All measurement modes -<br />
battery indicators, auto power off. Maximum rated working voltage 600Vac.<br />
RCD Isolation Test Transformer for Testing Portable RCD Unit<br />
pRO,ITx125VA-RCD AU<br />
RCD Isolation Test Transformer for Testing portable RCD units. Input 240V<br />
50Hz and output 230V 125VA thermally protected isolation transformer.<br />
This is only suitable for testing portable RCDs and by using this isolation<br />
transformer will avoid tripping of the whole circuit. It comes with 15Amps<br />
Australian / New Zealand Socket. Isolation test transformer can be used to<br />
test up to 150mA trip current<br />
Cropico DO7 Micro-Ohm Meter complete with Probe/lead Set<br />
CRO,DO7 AU<br />
Low resistance measurement for use in workshop, field or test facilities.<br />
Rugged construction, in a sealed plastic case with lid and carry handle.<br />
Advanced features including protection up to 415V rms at the measuring<br />
terminals, digital calibration and long scale length, 6,000 count. Rechargeable<br />
batteries >1h of continuous operation on lowest ranges, & 20h on all others.<br />
Battery charge indicators are provided. Internal charger will boost charge<br />
to 90% of full charge, switching automatically to a maintenance charge.<br />
Warning LEDs illuminate when an open circuit lead condition is detected.<br />
RS-232 output for connection to an external printer or pC. plug is provided<br />
for the connection of external start switch, eg. foot switch. Supplied with<br />
batteries, mains cord and test leads. For special lead sets we offer a variety<br />
of different styles, together with calibration standards.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
inSulatiOn/cOnditiOn/reSiStance teSterS<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Megger DLRO-10X Digital Low Resistance Ohmmeter<br />
MEG,DLRO-10x AU/NZ<br />
Automatically selects the most suitable test current, (up to 10Adc) to<br />
measure resistance from 0.1µΩ~2kΩ on 1 of 7 ranges. Real-time download<br />
of results and on-board storage for later download to a pC. Automatically<br />
detects continuity in potential and current connections. Visible warning of<br />
high voltages present at the terminals. Visible warning of current flowing in<br />
the test sample. Multiple operating modes including fully automatic. Alphanumeric<br />
keypad for entering test notes. User selectable high and low limits.<br />
Autoranging with manual option.<br />
Megger DLRO600 Digital Micro-Ohm Meter- High current<br />
MEG,DLRO600 AU<br />
Measures resistance between 0.1µΩ & 1Ω at high currents. provides<br />
test currents from 10A~600A subject to the load resistance and supply<br />
voltage. backlit liquid crystal display shows information needed to perform<br />
a test; all test parameters and measurement results are displayed. Range:<br />
0.1µΩ~999.9mW [subject to supply voltage and load resistance]. Accuracy:<br />
voltage ±0.5%, ±0.1mV, current ±0.5%, ±0.1A. Resistance: better than<br />
µΩ~100mW. power supply for full output: 207~265V 50/60Hz with a load<br />
less than 7mΩ including current leads [i.e. standard 5m 50mm² current leads<br />
only, 4mΩ load]. Reduced output: down to 100V 50/60Hz. Test current<br />
range 10A~600A unsmoothed dc in 1A steps, accuracy ±2%, ±2A. Test<br />
Modes manual, auto, continuous. Test Time 7s NORMAL /AUTO mode.<br />
Refreshed every 2s in CONTINUOUS mode. Voltmeter input impedance<br />
>200kW. Data Transfer real time or batch download via RS232 using AVO<br />
Download Manager. Storage Capacity 300 result sets and memo, battery<br />
backed for 10y.<br />
Megger 200A Micro-Ohm DLRO200<br />
MEG,DLRO200 AU<br />
Digital low resistance micro-ohm meter 200A.<br />
T&R DSM200 200A Micro-Ohm Meter<br />
T&R,DSM200 AU<br />
Max 200A. Max resolution 0.1µΩ. Digital display with RS232 output. AC<br />
mains operation. Complete with 3m leads.<br />
T&R DSM200 600A Micro-Ohm Meter<br />
T&R,DSM600 AU<br />
Max output 600A max resolution 0.1µΩ. Digital display with RS232 output.<br />
AC mains operation. Complete with 3m leads.<br />
Valhalla 4300B Digital Micro-Ohm Meter<br />
VAL,4300b AU<br />
Selectable current ranges 100µA~10A. Suitable for large electrical<br />
machinery. Resistance ranges 2mΩ~20KΩ with a max resolution of 0.1µΩ.<br />
basic accuracy 0.03% with a 4½ digit display. Supplied with heavy duty<br />
Kelvin leads.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 43
Megger BM21 500V/1/2/5kV Insulation Test Set<br />
MEG,bM21 AU<br />
Test voltages 25~5,000V in 25V steps. Insulation range to 1TΩ at 500V,<br />
5TΩ at 5kV. AC/dc voltage measurement 50V~1kV. Leakage current<br />
measurement. Capacitance measurement at end of test. Automatic<br />
discharge of capacitance. In-built test timer. Insulation burn mode - short<br />
circuit current 1mA nominal. battery life 8h, in-built charger for charging<br />
from mains or 12V dc.<br />
AVO/Megger BM11D Analogue/Digital 5kV Insulation Tester<br />
MEG,bM11D AU/MY<br />
Test voltages 500V, 1kV, 2.5kV and 5kV. Insulation range 10kΩ~500GΩ<br />
digital. AC/dc voltage measurement 50V~1kV. Timer 0~60min. Automatic<br />
discharge of capacitance. battery life 8h, in-built charger for charging from<br />
mains or 12V dc.<br />
Megger BM25 Insulation Tester<br />
MEG,bM25 AU/NZ<br />
Five kV insulation tester which is battery-powered, housed in a rugged case<br />
and has a large, analogue/digital LCD. A built-in timer makes both spot<br />
tests and polarisation Index (pI) testing easier to carry out. pre-set standard<br />
test voltages at 500V, 1, 2.5 & 5kV with variable test voltage in 25V steps.<br />
Displays capacitance at the end of a test to 10µF. Performs automatic PI,<br />
Step Voltage and Dielectric Discharge tests as well as providing an optically<br />
isolated RS232 port for downloading results during a test. Short circuit<br />
current: nominal 1.8mA, max 2mA. battery life: typically 8h.<br />
Megger CM500 Multifunction Installation Tester<br />
MEG,CM500 AU/NZ<br />
Combines the function of several instruments. Non-tripping loop test for<br />
tests on RCD protected circuits. RCD ramp test features actual tripping<br />
current. Functions are insulation, continuity, loop testing, RCD tests, voltage<br />
& frequency measurement. Phase indication, outlet polarity indication.<br />
Stores approximately 750 test results in memory for uploading to PC.<br />
> NEW<br />
Megger RCDT330 Residual Current Device Tester<br />
MEG,RCDT330 AU<br />
Tests standard, dc, selection and programmable RCDs. Ramp testing. Auto<br />
(remote) testing. 3ph safe. Enables testing on 110V centre tapped supplied.<br />
performs 1/21, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA,<br />
300mA, 500mA & 1000mA on general and selective (time delayed) RCDs.<br />
Tough rubber armoured case with built-in cover. Weatherproof to Ip54. USb<br />
interface for downloading test result.<br />
LEM Saturn Insulation Tester<br />
LEM,SATURNISO AU<br />
Test voltages 50~1,000V in steps of 10V. Max range 30GΩ. Measures<br />
ac/dc voltage to 600V, resistance to 30kΩ. Digital and analogue display.<br />
Battery operated.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
inSulatiOn/cOnditiOn/reSiStance teSterS<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Megger CBT2 Earth Leakage Breaker Tester<br />
MEG,CbT2 AU<br />
Residual current device (RCD)/safety switch, circuit breaker tester. Twelve<br />
ranges from 6~500mA. Displays tripping time in ms.<br />
Metrel MI 2121 AUS Advanced RCD Tester<br />
MET,MI2121AUS AU<br />
Exceeds all requirements of AS/NZS3760:2003. Stores up to 500 tests.<br />
Interface RS232 Software.<br />
Megger BT51 Low Resistance Ohmmeter<br />
MEG,bT51 AU<br />
Uses 4 terminal method with helical duplex dual pronged probes. Test<br />
current 2A nominal at 2Ω. Ranges 2, resolution 1mΩ, 20mΩ, resolution<br />
10µΩ. Accuracy at 0~500C, ±1% of reading, ±2digits. Display LED 3½<br />
digit. Power supply internal NiCd rechargeable batteries, typically around<br />
2,000 tests at 5s duration. Re-charge time around 10h with 240Vac mains<br />
power. Nett weight 45kgs.<br />
Megger LT6 Digital Loop Tester<br />
MEG,LT6 AU<br />
Earth fault loop impedance tester 20Ω range 0.01Ω resolution, 2kΩ range<br />
1Ω resolution. Single & 3ph systems can be tested. Used with MEG,CbT2<br />
to test compliance to AS2381.1 (electrical wiring for hazardous areas).<br />
Tests automatically when connection to circuit is made. Neons indicate fault<br />
conditions.<br />
Megger MFT1502 Combined Insulation, Loop & RCD Tester<br />
MEG,MFT1502 AU<br />
Tests fixed wiring in accordance with International and National Wiring<br />
Standards. Display digital/analogue arc LCD. Voltage measurement<br />
automatic selection ac or dc up to 270V. Continuity testing 200mA from<br />
0.01~99.9Ω, automatic continuity testing commences the moment the test<br />
probes touch the circuit to be tested. Audible tone to confirm test. Safety<br />
check for presence of a voltage. Variable buzzer threshold selectable from<br />
2~100Ω in 6 steps. Insulation testing 250, 500V & 1kV. Safety lockout<br />
at voltages greater than 55V. Auto discharge facility safely discharges all<br />
circuits after insulation test. Low current loop test, a 3-wire non-tripping<br />
0.01Ω loop test designed to prevent RCD tripping. High current loop test<br />
at 25A provides a fast test where no RCD is fitted. Supply voltage and<br />
polarity indication at 55V~280V, 45Hz~65Hz phase to phase. phase~phase,<br />
phase~neutral and phase~earth loop tests are possible. Loop measurements<br />
from 55V~480V. prospective short~circuit current (pSC), a high current loop<br />
test, is provided for rapid measurement of loop currents, both at the socket<br />
outlet and distribution board. Ranges from 1A~19.9kA with a resolution of 1,<br />
10 & 100A depending on range auto-ranging. RCD testing 10mA~1000mA<br />
with both 0 & 180O phase angle. RCD ramp test measures the RCD trip<br />
current. Displays actual trip current on all RCD ranges instead of trip time.<br />
LED torch in illuminated probe for low light level areas. Ip54<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 45
ELEC<strong>TR</strong>ICAL POWER<br />
46<br />
inSulatiOn/cOnditiOn/reSiStance teSterS<br />
Kikisui TOS-5051 5kV ac/dc Hi-Pot Tester<br />
KIK,TOS-5051 AU<br />
High voltage ac/dc insulation test set. Ranges 0~2.5kV & 0~5kV. Max<br />
output ac 100mA, dc 10mA. pass/fail comparator included.<br />
> NEW<br />
Megger Digital Earth Test Clamp<br />
MEG,DET20C AU<br />
Measures ground resistance from 25mΩ~1550Ω . Measures ground<br />
leakage current from 0.2mA~35A. Automatic self calibration. Auto ranging.<br />
High and low alarms. Large memory. Download to Megger Download<br />
Manager. Measures earth resistance in installations such as buildings,<br />
pylons and RF transmitter sites. Use for the inspection and verification of<br />
lightning protection systems. Large jaw opening.<br />
Megger Det5/3R Ground Resistance Tester<br />
MEG,DET5/3R AU<br />
MEG,DET5 NZ<br />
Checks resistance of electrical systems including soil resistivity. Measures<br />
resistance from 0.01~19,999Ω in 4 ranges. LCD 3½ digit display. Operating<br />
frequency 128Hz. Complete with earth testing kit including spikes and wire.<br />
3M Model 701 Micro-ohm ESD Surface Tester<br />
3M,701 AU<br />
Tester for static control surfaces, table mats, field service kits, floor coverings,<br />
etc. Test voltages 10 & 100V. Resistance range 0~100GΩ.<br />
Baur DAP75 Insulating Oil Tester<br />
bAU,DpA75 AU<br />
Output voltage 0~75kV rms. Selectable programmes to international<br />
standards. Integral printer. RS232 interface.<br />
AVO OTS60PB Transformer Oil Tester<br />
AVO,OTS60pb AU<br />
Test voltage 60kV max at 61.8Hz. Fully automatic operation. Rechargeable<br />
battery operation. RS232C interface.<br />
BJM All-Test III Motor, Coil and Winding Tester<br />
bJM,ALL-TEST3 AU<br />
Tester for single or polyphase ac motors, generators, transformers or<br />
dc motors. Use to test any motor, coil or winding to determine insulation<br />
condition between windings, windings and frame, open circuits. Also<br />
measure phase balance and angle. Impedance (z) 5~1,000Ω. Inductance<br />
(L) 0.35mH~1.6H. Capacitance (C) 100mF~50nF. power factor (Fi) 0~90O .<br />
Insulation 0~20MΩ @ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz<br />
(times 2).<br />
BJM All-Test IV PRO 2000<br />
bJM,ALL-TEST-4 AU<br />
Tests single or polyphase ac motors, generators, transformers or dc motors.<br />
Use to test any motor, coil or winding to determine insulation condition<br />
between windings, windings and frame, open circuits. Measure phase<br />
balance and angle. Impedance (z) 5Ω~1kΩ. Inductance (L) 0.35mH~1.6H.<br />
Capacitance (C) 100mF~50nF. power factor (Fi) 0-90 O . Insulation: 0~20MΩ<br />
@ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz (times 2).<br />
LEM Saturn GEO Easy Earth Tester<br />
LEM,SATURN GEO EASY AU<br />
Waterproof instrument (rubber protective cover IP56). Measures earth<br />
resistance, 3 or 4 pole. Soil resistivity. Measures resistance from 0~20kΩ.<br />
Display 4 digit back light 25mm LCD. Operating frequency 128Hz. Single<br />
button user interface. Complete with earth testing kit including 4 stakes, 3<br />
reeled cables, clips and carry case.<br />
LEM Saturn GEO X Earth/Soil Resistance Tester<br />
LEM,SATURN-GEO-x AU<br />
Automatically tests earth/soil resistance 3, 4 pole and stakeless with CT.<br />
Optimise output frequency (manual or automatic) 0.001~300kΩ at 20 &<br />
48Vac, frequency 94, 205, 111, & 128Hz. Displays all measuring results<br />
for as long as desired. programmable limits. Optical and audible over-limit<br />
warning. Splash-proof case Ip56 (outdoor application). Measurements with<br />
current clamps: selective, stakeless. Resistance measurements with 250mA<br />
short circuit current. Output of measured values via interface on printer or<br />
PC.<br />
LEM Saturn 100plus Safety Tester<br />
LEM,SATURN100+ AU<br />
Confirms correct operation of RCD protection, resistance of all aspects of<br />
protective earthing systems, loop impedance, line-neutral polarity, predictive<br />
short circuit current, phase sequence and voltage. RCD current 10mA~1A.<br />
Tripping time 1~500ms. Tripping current measurement with intelligent ramp.<br />
Fault voltage 0.1~99.9V. Loop and earthing resistance 0.15W~10kW. Earth<br />
electrode voltage (SEV 3569) up to 199V. Short-circuit current 1A~9.99kA.<br />
Loop/line internal resistance RLOOp 0.07~200W. Nominal line voltages<br />
100~435V. battery-saving, automatic switch-off, typical battery service-life<br />
3,500 insulation measurements.<br />
Multi-amp MET-2 Clamp-On Earth Tester<br />
MUL,MET-2 NZ<br />
Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2<br />
clamp CTs without disconnecting the earth conductor. Measures dc loop<br />
resistance without any influence from other conductors.<br />
Seaward Europa Advanced Portable Appliance Tester<br />
SEW,EUROpA pAT AU<br />
Records results, compliant with AS/NZS 3760: 2001/2003 can be printed as a<br />
certificate using the serial/parallel adaptor. bar-code reader included. Earth<br />
continuity output current 100mA~25A ac. Range 0.01~20Ω. Accuracy ±5%<br />
of reading ±2 digit. Insulation test range, 100kΩ~100MΩ. Test voltage,<br />
250, 500Vdc. Resolution 0.01MΩ. Includes plug adaptor to test, EpODs<br />
and extension leads (IEC - IEC and Australian).
Seaward PAT Management Software (WIN)<br />
SEW,pATGUARD-SW-WIN AU<br />
Seaward’s pATGuard plus takes a significant leap in electrical safety<br />
management software. Its unique “Drag and Drop” presentation makes<br />
the software intuitive and very easy to use. pATGuard both uploads and<br />
downloads appliance information and test results from the Europa xE,<br />
Europa plus and Supernova xE. Users have a complete visual overview<br />
of all appliances in terms of locations and test status. Appliances are<br />
simply dragged and dropped from one location to another. Repeat testing<br />
requirements are easily displayed allowing scheduling of tests to be<br />
conveniently managed and uploaded into the appliance tester<br />
Trolley Suitable for SEW,XE3760PKIT+ SUPERNOVA PAT Tester<br />
SEW,<strong>TR</strong>OLLEY-3760pKIT<br />
This trolley is specially designed for SEW,xE3760pKIT+ and very useful for<br />
portable Appliance Tester, Seaward xE 3760 pKIT+. This trolley comes with<br />
the following accessory and contains four layer shelving, extension board<br />
with five socket 240V / 10 Amps, extension cable approximately 25 meters,<br />
2 Nos. of elastic tie rope and a plastic bin. By using this trolley one can fit all<br />
the required instruments for portable Appliance Testing and this will improve<br />
performance and higher productivity.<br />
Seaward PAC 3760 Appliance Checker<br />
SEW,pAC3760 AU<br />
performs the following tests in conformance to AS/NZS 3760:2000, earth<br />
bond, insulation & polarity tests, also leakage current tests for Class I &<br />
Class II appliances and leads (leakage current testing of appliances, which<br />
requires power to “switch” them on, is the method required by AS/NZS3760:<br />
2003). Features simple pass/fail indication. Unique 3 button operation.<br />
Class I, class II and leakage current. Automatic test sequence senses<br />
an IEC or extension lead then performs a polarity test. Detects that the<br />
appliance under test is switched “On”. Earth bond test is set at 10A and is<br />
capable of fusing a poor earth. Large LCD.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
inSulatiOn/cOnditiOn/reSiStance teSterS<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Seaward Supernova XE3760+ PAT System with Printer and<br />
Scanner<br />
SEW,xE3760pKIT+ AU<br />
SEW,xE3760pKIT NZ<br />
Includes results label/tag printer and barcode scanner. performs all AS/<br />
NZS3760: 2001/2003 compliant tests, including class 1 & class 2 leakage<br />
current 5mA/1mA, an earth conductor bond test up to 25A at 3V (approx.<br />
100W) and 250Vdc MOV insulation resistance tests. Stores 5,000 tests<br />
in internal memory by appliance ID, including test type, detailed results,<br />
test time & date, next test due date, site & location. Calibrated resolution<br />
better than the required 5% of full scale across all ranges as specified by<br />
the Standard. Full QWERTY keyboard, and bar code reader for input.<br />
Durable plastic adhesive test label/tags printed to attach to appliances and<br />
leads includes user ID (logo optional on request) and test barcode ID, saves<br />
transcription. Compatible with Seaward pATGuard plus software package.<br />
PRO-TAG Thermal Transfer Printer<br />
pRO,TAG-pRINTER AU<br />
print durable and permanent synthetic test tags on-site directly from your<br />
Europa xE, Europa plus or Supernova xE appliance safety testers. Easy<br />
- test the appliance, print the tag, peel it off and stick it on. Accountable - the<br />
pro-Tag systems are fool proof and tamper evident. Test tags are generated<br />
direct from the tester’s test results. Fast & Cheap - no more hand writing<br />
test tags and pro-Tag test tags are less than half the price of vinyl tags.<br />
Accurate - tags are printed with appliance number, appliance bar code, test<br />
date, user name and test status from the tester’s memory. Customise - you<br />
can personalise the test tag with your own company logo.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 47
ELEC<strong>TR</strong>ICAL POWER<br />
48<br />
pOWer analySerS & recOrderS<br />
Model Type<br />
VOL,pM3000A<br />
VOL,VpAS<br />
LEM,TOpAS1000<br />
LEM,MEMObOx 300<br />
DRA-bMI,px5<br />
DRA-bMI,px5-400<br />
DRA-bMI,pG4400<br />
REL,1600<br />
HIO,3196-pQA<br />
power quality/<br />
demand<br />
Software<br />
power quality/<br />
demand<br />
Network<br />
performance<br />
analyser<br />
Universal power<br />
quality/demand<br />
Universal power<br />
quality/demand<br />
Universal power<br />
quality/demand<br />
Volt<br />
Inputs<br />
Current<br />
Inputs<br />
3 3<br />
4 4<br />
3 4<br />
4 4<br />
Current (A)<br />
(Max,rms)<br />
30 A direct<br />
1 kA/3kA CT<br />
3kA<br />
3 kA/6 kA<br />
3 kA/6 kA<br />
3 kA/6 kA<br />
5 5 1 kA<br />
5 kA<br />
Features Output<br />
400 Hz, Harmonics 99th<br />
Very high accuracy<br />
NATA certified unit available<br />
Sampling 10MHz<br />
Harmonics 50th<br />
Interharmonics 5~2,500Hz<br />
(in steps of 0.5Hz)<br />
Sampling 1Mhz transient<br />
Harmonics 63rd<br />
Flicker, pst, plt<br />
Sampling 1Mhz transient<br />
Harmonics 63rd<br />
Flicker, pst, plt<br />
Sample rate 256/cycles<br />
Harmonics 63rd<br />
Flicker, pst, plt<br />
Sampling 4MHz<br />
Harmonics 63rd<br />
Sampling 2 MHz<br />
Harmonics 50th<br />
Display, RS232,<br />
+ more<br />
RS232,Ethernet, software<br />
RS232 serial cable<br />
CODAM plus software<br />
128Mb, compact flashcard<br />
128Mb, compact flashcard<br />
128Mb, compact flashcard<br />
Parallel, software<br />
Display, ethernet, RS232,<br />
Compact flash card<br />
HIO,3197pQA 5 kA Harmonics 50th Display, USb<br />
power quality/<br />
CHK,PM20 demand<br />
3 4<br />
1 kA/3 kA Sampling 11.4kHz, THD Display, RS232, software<br />
CHK,PM30 1 kA/3 kA<br />
Sampling 11.4kHz,<br />
Harmonics 48th, Ip56<br />
Display, RS232, Software<br />
RS232 POWERview<br />
CHK, PM30 Plus<br />
3 kA<br />
THD and individual to 48th harmonics<br />
Flexible Cts/Clamp Cts<br />
software,<br />
4Mb memory<br />
CHK,pM40pQA RS232, USb, 15Mb Memory<br />
DRA-bMI,pR150<br />
150 A Universal current clamp ac/dc<br />
CT<br />
DRA-bMI,pR1500 1500 A Universal current clamp ac/dc<br />
DRA-bMI,pR6035A/36 Flexible CT 6000A ac Flexible CT, 36” length<br />
DRA-bMI,<strong>TR</strong>2021<br />
CHK,CR100 100<br />
CT<br />
CHK,CR500 500<br />
1-30A Instrument CT, 48Hz – 10kHz<br />
DRA,<strong>TR</strong>2510 10A ac Instrument CT, 1-10A<br />
CHK,CRT1000L 1 Ka<br />
CHK,CT3000L 1<br />
CHK,CK1 3ph current<br />
1<br />
CHK,CK5 converter<br />
5<br />
MEG,pA9 pLUS<br />
Portable power<br />
analyser<br />
4 5 6 kA<br />
ALG,UpM6001 Power demand 3 3+aux 20 A/1 kA<br />
ALG,UpM6100<br />
power quality/<br />
demand<br />
4 4<br />
20 A direct<br />
3 kA<br />
ALG,RET Flexible CT 3 kA<br />
ALG,C173<br />
Precision CT for<br />
earth leakage<br />
1 mA~1 kA<br />
Up to 63rd harmonics & THD<br />
Sample rate 256/cycle<br />
Current voltage simultaneously<br />
600~6,000 flexible CTs<br />
Harmonics 25th<br />
For 4th current channel of UpM<br />
Harmonics 50th, 14~500Hz<br />
12Mb internal memory<br />
256Mb compact flash card<br />
Display, printer, RS232,<br />
software
Model Type<br />
HIO,2331-20RpMS<br />
HIO,2332-2RpMS<br />
YEW,CW140<br />
Power demand<br />
Volt<br />
Inputs<br />
Current<br />
Inputs<br />
AVO, pENTA-pLUS-DMM 3ph DMM/demand 3<br />
BMI,8800<br />
bMI,A-111 Voltage plug-in<br />
bMI,A112<br />
bMI,A116<br />
Power Quality 4 4 CTs<br />
CT<br />
Current (A)<br />
(Max,rms)<br />
Features Output<br />
4 440 0~500 A Remote power measurement Ethernet<br />
3<br />
500 A~<br />
700 A<br />
100 direct/<br />
3 kA CT<br />
600<br />
400Hz, Harmonics 13th<br />
ac/dc, voltage phase angle<br />
400Hz, Harmonics 30th,<br />
Sampling 2MHz<br />
Display, FDD, RS232,<br />
optional printer<br />
Display, RS232,<br />
Parallel printer<br />
Chart, FDD, RS232,<br />
Viewing software<br />
bMI,A120<br />
3 kA<br />
DRA,808 Power demand 3 3CTs Chart<br />
DRA,<strong>TR</strong>2015 CT 3 kA<br />
DRA,635-G5 Termination 5 A<br />
DRA,646-3<br />
DRA,626<br />
Power Quality<br />
4 Chart<br />
DRA,pA6030-1 Graphics print out<br />
3<br />
DRA,pA6024A Harmonics 7th<br />
MET,pF-1-F Current logger 69kV RS232, software<br />
MET,Mx2040 1ph power demand<br />
2 kA Display, analogue out<br />
1CT<br />
MET,Mx200 Clamp on Ammeter 1<br />
200 A Display<br />
LEM,ANALYST-2060 1 ph Power Demand 1 2 kA Harmonics 25th Display,RS232, IR, software<br />
HIO,8710<br />
DRA,CAF-RS232<br />
DRA,CAF-ETHERNET<br />
Voltage/Current<br />
Recorder<br />
Communication<br />
adaptor<br />
Communication<br />
adaptor<br />
Chart<br />
3 3 1500 3 channel recorder, voltage or current Chart<br />
Fibre to RS232 with Node link software<br />
Fibre to Ethernet with Node link<br />
software<br />
DRA,128MbFMC Flashcard Ultra high speed0<br />
DRA,DVMDS Math Driver Software<br />
pRO,MAGNUS-2.2KV Step Up Transformer 1 1<br />
Rescue kit for any corrections – logged<br />
data<br />
Prepare excitation curves for instrument<br />
transformer, demagnetize CT and<br />
conduct trun ratio test on VT<br />
ACR,pOWERWATCH Disturbance Logger 1 Voltage disturbance recorder<br />
HAW,5000 Power demand 3 3 1000 Energy monitoring<br />
DRANETZ ac/dc Current Clamp 3 - 150A<br />
DRA,pR150 AU<br />
AC/dc current clamp/probe 3 - 150A RMS, max conductor size is 52mmØ.<br />
Current clamp/probe is suitable for any of new Dranetz-bMI models DRAbMI,pG4400,<br />
DRA-bMI,px5, DRA-bMI,px5-400. Current clamp/probe is<br />
very useful for current measurement through CT current transformer. CT<br />
Ratio can be selected on the new Dranetz-bMI above-mentioned models.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
pOWer analySerS & recOrderS<br />
RS232<br />
Dranetz ac/dc Current Clamp 3 - 1500A RMS<br />
DRA,pR1500 AU/NZ<br />
Max conductor size is 52mmØ. Current clamp is suitable for any of new<br />
Dranetz-bMI models DRA-bMI,pG4400, DRA-bMI,px5, DRA-bMI,px5-<br />
400. Current clamp/probe is very useful for current measurement through<br />
CT current transformer. CT Ratio can be selected on the new Dranetz-bMI<br />
above-mentioned models.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 49
ELEC<strong>TR</strong>ICAL POWER<br />
50<br />
pOWer analySerS & recOrderS<br />
Dranetz-BMI Power Xplorer PX5<br />
DRA,px5 AU/NZ<br />
provides the full range of measurements include V, I, W, VA, VAR, TpF, DpF,<br />
Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum<br />
(V, I, W) to the 63rd, Flicker (pst, plt), Crest factor, K factor, transformer derating<br />
etc. Min/Max/Avg values are determined in ½ cycle RMS steps. Asset<br />
comes with ac flexible current clamp DRA-bMI,RR3035A/24, current range<br />
30/300/3,000A ac only. Can be extended to different ranges of measurement<br />
both ac & dc by selecting appropriate current clamps. High-speed transient<br />
capture (1MHz sampling rate) and the full range of arithmetic, vector and<br />
sequence parameters to evaluate distorted and un-balanced loads as<br />
defined in IEEE 1459. Exceeding high/low limits of any active parameter<br />
can trigger logging. Voltage & current disturbances can be triggered by<br />
peak value, wave-shape change & cycle-by-cycle RMS value change. preevent<br />
& post-event waveform capture cycles are user adjustable. Voltage<br />
& current channels can be cross-triggered. Suitable for both ac/dc power<br />
quality measurements. (Universal power Quality Analysers). DRA-bMI,px5<br />
analysers can be used for power quality measurements, current inrush<br />
(cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage<br />
logging), long term monitoring and continuous logging at 1s intervals. Four<br />
differential voltages and current channels can be used independently. DRAbMI,px5<br />
is Class A compliant with IEC Standard 61000-4-30 ‘power Quality<br />
Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic &<br />
Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data<br />
is collected at 256 samples/cycle/channel.<br />
Dranetz-BMI Power Xplorer PX5-400Hz<br />
DRA,px5-400 AU<br />
Specificaion as above but with 400Hz capability suitable for aviation and<br />
military use.<br />
Dranetz Current Clamp 1 - 30A 48Hz~10kHz<br />
DRA,<strong>TR</strong>2021 AU<br />
Set of 3 current clamps 1~30A RMS, 48Hz~10kHz. Max conductor size<br />
0.47”. Description as for DRA,pR6035A/36 current clamps above.<br />
Dranetz-BMI Power Guide 4400<br />
DRA,pG4400 AU/NZ<br />
provides the full range of measurements include V, I, W, VA, VAR, TpF, DpF,<br />
demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum<br />
(V, I, W) to the 63rd, flicker (pst, plt), crest factor, K factor, transformer<br />
de-rating etc. Min/max/avg values are determined in ½ cycle RMS steps.<br />
Asset comes with ac flexible current clamp DRA-bMI,RR3035A/24, current<br />
range:- 30/300/3,000A ac only. Can be extended to different ranges of<br />
measurement ac/dc by selecting appropriate current clamps. Has the full<br />
range of arithmetic, vector and sequence parameters to evaluate distorted<br />
and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits<br />
of any active parameter can trigger logging. Voltage & current disturbances<br />
can be triggered by peak value, wave-shape change & cycle-by-cycle RMS<br />
value change. pre-event & post-event waveform capture cycles are user<br />
adjustable. Voltage & current channels can be cross-triggered. Suitable for<br />
both ac/dc power quality measurements.(Universal power Quality Analysers).<br />
DRA-bMI,pG4400 analysers can be used for power quality measurements,<br />
current inrush (cycle-by-cycle current logging), fault recording (cycle-bycycle<br />
voltage logging), long term monitoring and continuous logging at 1s<br />
intervals. Four differential voltages and current channels can also be used<br />
independently. DRA-bMI,pG4400 is Class A compliant with IEC Standard<br />
61000-4-30 ‘power Quality Measurement Methods’ (also AS DR04066),<br />
AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-<br />
15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.<br />
Dranetz Flexible Current Clamp 60/600/6,000A<br />
DRA,pR6035A/36 AU<br />
Set of 3 flexible current clamps 60/600/6,000A RMS, max conductor<br />
size/length of clamp is 36”. Current clamps are suitable for any of new<br />
Dranetz-bMI Models. DRA-bMI,pG4400 / DRA-bMI,px5 / DRA-bMI,px5-<br />
400. Current clamp/probe is very useful for current measurement through<br />
CT current transformer. CT Ratio can be selected on the new Dranetz-bMI<br />
above-mentioned models.<br />
Dranetz Current Clamp Probe 0~10A RMS<br />
DRA-bMI,<strong>TR</strong>2510 AU<br />
Set of 3 current clamps 0~10A RMS. Max conductor size 0.47”. Description<br />
as for DRA,pR6035A/36 current clamps above.<br />
Dranetz-BMI, 128 MB Flash Memory Card (Industrial Grade)<br />
DRA,128MbFMC AU/NZ<br />
Suitable for the following Dranetz -bMI Models:- DRA-bMI,px5, DRAbMI,px5-400,<br />
DRA-bMI,pG4400.
Dranetz Communications Adapter - Fibre to Ethernet with Node<br />
Link SW<br />
DRA-bMI,CAF-ETHERNET AU<br />
Communications Adapter - Fibre to Ethernet with NodeLink Software and<br />
Moxa Networking Software for the following Dranetz-bMI Models:- DRAbMI,px5,<br />
DRA-bMI,px5-400, DRA-bMI,pG4400.<br />
Dranetz View Math Driver Software (Add ON)<br />
DRA-bMI,DVMDS AU<br />
In 4 essential areas, the Math package will improve measurements:-<br />
Rescue Kit. Ever hooked up a probe the wrong way? May be forgotten to<br />
check if the actual time in your instrument is running correctly? Or could you<br />
have possibly forgotten to set the correct K-factors? The Math -package<br />
helps you to correct these errors, re-calculate parameters from available<br />
waveform data, invert waveforms and much more. Improve Measurements<br />
/ Reports. Calculate additional parameters for your Multi-DAQ TASK<br />
Card, fault-recorder/inrush mode measurements, with the math driver the<br />
following additional trends will be created for Multi-DAQ data files: V rms,<br />
Watts, VAR’s, VA, True pF, V thd (%fundamental), I thd (abs current) Voltage<br />
Frequency (for internal trigg) and Net Totals V rms, Amps, W, VAR & VA.<br />
Generate More parameters from waveform data. Showing Displacement<br />
power Factor (DpF) instead of K-factor. Rename inputs. Energy ON/OFF<br />
peak calculations. Mathematical expressions and formulas can be used<br />
to plot additional user-defined channels within both the time-plot chart<br />
and the waveform chart. Advance analysis, watt harmonics, symmetrical<br />
components, etc.<br />
Dranetz 646-3 Disturbance Recorder<br />
DRA,646-3 AU<br />
Accepts up to 3 ac line inputs 50~600V, 1 neutral to ground input 5~200V,<br />
& 1 dc voltage input 1~100V. Monitors and records impulses, sags, surges,<br />
under and over voltages and frequency variations on 1~3ph ac, 47~63Hz.<br />
Impulse duration 1~1,000µs.<br />
Dranetz 626 Power Disturbance Monitor<br />
DRA,626 AU<br />
For use with up to 5 x pA series plug-ins. Monitors sags, surges, impulses<br />
and changes in frequency.<br />
ACR Voltage Disturbance Logger<br />
ACR,pOWERWATCH NZ<br />
Single phase 230V disturbance logger. Plugs into a standard 230V 3pin<br />
power point. Stores up to 4000 events such as sags, surges, outages,<br />
impulses & frequency variations. Supplied with software & serial cable for<br />
programing, uploading and printing results.<br />
BMI 8800 Power Disturbance Analyser<br />
bMI,8800 AU<br />
Eight inputs giving simultaneous voltage and current (optional probes<br />
required) monitoring of up to 4 channels each. FDD included. Each<br />
disc stores 600 disturbances for transfer to the internal graphics printer.<br />
Harmonics measurement option included for up to the 40th harmonic of<br />
50Hz. Max input voltage 600V rms or dc. Eight extra channels included for<br />
sensor outputs, etc. Operates from ac mains or 11~16Vdc. In-built UpS.<br />
BMI A-111 ac/dc Voltage Impulse Probe<br />
bMI,A-111 AU<br />
For bMI,4800/8800. Uses probe channels to increase the number of voltage<br />
inputs that can be monitored. Ranges 0~600V rms, 0~100V dc. Impulses<br />
0V~2.4kV peak.<br />
BMI A112 Current Probe for BMI 8800<br />
bMI,A112 AU<br />
For bMI,4800/8800. Measures current waveforms to 600A and allows<br />
graphic representation on bMI,4800 printout. Jaw opening 50mm. True<br />
rms measurements for motor startup, current surges, etc. Range can be<br />
extended to 3kA by using DRA,<strong>TR</strong>2015 in secondary loop configuration.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
pOWer analySerS & recOrderS<br />
BMI A116 600 Amp Clamp-on Probe for 8800<br />
bMI,A116 AU<br />
Aperture 50mmØ. bandwidth 3kHz.<br />
BMI A120 3000 A Clamp-on Probe for 8800<br />
bMI,A120 AU<br />
Aperture 63 x 160mm. bandwidth 3kHz.<br />
Metrosonics PF-1-F Overhead Profiler<br />
MET,pF-1-F AU<br />
Distribution line profilers for current measurement on power lines. Logs<br />
current consumption to internal memory. Set of 3 profilers with one display<br />
module. Windows software included. Current range 5~1000A. Resolution<br />
1A. Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate<br />
1s~10min. Memory 64k readings. Data storage modes: stop when full or<br />
wrap around. Data retention after low battery shutdown 30d. Min conductor<br />
spacing 600mm.<br />
> NEW Hioki Remote Power Measurement System 2331-20<br />
RPMS SmartSite<br />
HIO,2331-20RpMS AU<br />
For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3 wire &<br />
3ph 3 wire up to 3 circuits. Provides via a PC, management of measurement<br />
data to support energy and environmental management. Modulated<br />
measurement units take advantage of a variety of infrastructure to collect<br />
measurement data. Use as a stand alone logger and for remote monitoring.<br />
Use as a pC measurement logger keeps measuring and continuously saves<br />
the data. Measurement modules comes with memory and clock. build a<br />
customised and remote measuring system by utilizing existing data network.<br />
Modules for temperature, humidity, instrumentation and pulse, power module<br />
for multiple circuits. Large internal memory. Communication module with<br />
built-in real-time clock tracks the data of each measurement module to the<br />
second. Air Module for constructing SS wireless systems.<br />
> NEW Hioki Remote Power Measurement System 2332-20<br />
RPMS SmartSite<br />
HIO,2332-20RpMS AU<br />
Description as for HIO,2331-20RpMS above.<br />
Hawk 5000 3 Phase Power Demand Logger<br />
HAW,5000 NZ<br />
Three phase wye power demand logger. Records kVA, kW, V, I, Freq & pF.<br />
Uploads data to a pC for graphing and printing. Supplied with software and<br />
3 x 1kA clamps.<br />
Dranetz 808 Power Demand Analyser<br />
DRA,808 AU<br />
Displays and prints on in-built printer - V, A, pF, kW, kWh, kV/A, kVAR,<br />
demand, time and date for single and three phase systems. For use with<br />
DRA,635-G5 terminations or <strong>TR</strong> series clamp-on current transformers.<br />
Dranetz <strong>TR</strong>2015 Clamp-on Current Transformer<br />
DRA,<strong>TR</strong>2015 AU/NZ<br />
For DRA,808. Ranges 1, 2 & 3kA. Requires DRA,635-G5 termination.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 51
Voltech PM3000A 3 Phase Power Analyser<br />
VOL,pM3000A AU<br />
Capable of making measurements of all standard electrical characteristics<br />
of 1 & 3 phase supplies. Measures inrush current and crest factor, load<br />
impedance and harmonic analysis, energy and max demand, extendable<br />
using current and potential transformers. Frequency range dc~500kHz.<br />
parameters W, VA, Var, V, A, pF, peak voltage and current, crest factor,<br />
impedance, peak inrush current, voltage and current harmonics, 99th order,<br />
THD, Hz, Wh, VAh, Varh, Amph, average pf. Input coupling may be ac or ac<br />
+ dc. Outputs printer, recorders (8), and oscilloscopes. IEEE, RS232C, and<br />
centronics interfaces and waveform output derived from current and voltage<br />
inputs are included. Accuracy V & A 0.05%, power 0.1%. Input ranges<br />
voltage 0.5V~1kV rms, current 0.05~30A rms (200A peak). Accessories<br />
3 x 1kA clamp-on CTs, and 3 x precision 100A/1kA dual range current<br />
transformers 0.2% (not clamp on).<br />
Voltech PM3000A with NATA Calibration<br />
VOL,pM3000A-NATA AU<br />
Specifications as above but with NATA calibration.<br />
LEM Analyst 2060 Hand-held 1 Phase Clamp-on Power Meter<br />
Analyser<br />
LEM,ANALYST-2060 AU<br />
Measure, record and log W, VA, VAR, kWh, and power factor. Current to<br />
2kA auto-ranging ac or dc. peak, Crest Factor, THD, DF and frequency for<br />
voltage (4~750V) and current. Harmonics to the 25th order. Time base is<br />
selectable from 2ms/div~50ms/div. Large backlit multi parameter display,<br />
with oscilloscope and chart modes. Memory size: 8 screens smart save and<br />
up to 10,000 readings. Jaw opening capacity 60mmØ. Typical battery (6 x<br />
AA alkaline) life 24h without backlight.<br />
LEM Topas 1000 Power Network Analyser<br />
LEM,TOpAS1000 AU<br />
Measures all relevant parameters in one measurement system. Inputs<br />
(isolated) voltage 4 channels, 200mV~1kV, current 4 channels, supplied<br />
with 4 x 0~10A, 10~100A ac clamp-on CTs and 4 x (unit powered) 0~3kA<br />
LEM-Flex current sensors. Can be configured for 8 voltage channels.<br />
Measuring functions rms, V(U) voltage imbalance, positive, negative & zero<br />
phase sequence, phasor (vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz),<br />
energy, on-line oscilloscope, power and multimeter, harmonics (by power/<br />
direction, magnitude & phase), inter-harmonics, THD, flicker, transients<br />
(100kHz~10MHz), will capture events from 0.1µs in duration. Software<br />
configured manual or auto trigger levels, ethernet or serial interface, memory<br />
>540Mb/HDD.<br />
LEM Memobox 300 Network Performance Analyser<br />
LEM,MEMObOx300 AU<br />
Weatherproof (Ip65)3ph power analyzer. High accuracy to Class A IEC<br />
61000-4-30. Suitable for 50Hz or 60Hz systems. LEMflex flexible current<br />
probes with ranges 15, 150, 1,500 & 3,000A suitable for conductors up<br />
to 178mmØ. Voltage ranges from 115~830V on 3 or 4-wire systems.<br />
Measures V, A, kW, kVA, kVAR, kWHr, pF, Hz, crest factor, distortion power,<br />
THD, individual harmonics of volts & current up to 50th harmonic, flicker and<br />
ripple control signal levels. Power measurements by either 2 or 3 wattmeter<br />
method. power supply 88~415V either from measurement leads or separate<br />
supply. Memory size 4Mb with 5,700 sampling intervals. Sampling intervals<br />
selectable from 1s~60min. Sample interval of 5min records for >19Days.<br />
Linear or circular (overwrites earliest data once full) memory. Records<br />
average, 10ms min & 10ms max in each interval. Captures motor start<br />
current spikes with corresponding voltage-dips. Captures up to 13,000<br />
voltage sag/surge events 10ms or longer. Weight 1.1kg.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
pOWer analySerS & recOrderS<br />
LEM Elmes 693 3Ph Power Logger<br />
LEM,603 NZ<br />
Logs, voltage, current & pF. True RMS: VA, VAr, pF, Volts, A & frequency.<br />
Sampling rate is 1s. Statistical measurement interval can be set from<br />
1~60min. Supplied with flexible 1kA Rodowski CTs, 5A clip-on CTs and<br />
software for programming and uploading results. Accuracy, active power<br />
±2%, reactive power ±3%, phase angle ±3%, voltage ±1.5%.<br />
Reliable Power Systems 1600 Analyser<br />
REL,1600 AU<br />
Power analyser for parameter, demand, and disturbance measurement<br />
and long term monitoring. pC required for download - no onboard display.<br />
Complete with 1kA CT’s & 5A CT’s. V & I sampled at 8kHz, min/max values<br />
have 1 cycle response. Impulses sampled at 2 & 4MHz software selectable.<br />
Max input voltage 700V rms. Notebook pC with Win 95 and Office 97<br />
included.<br />
Algodue UPM6001 Power/Demand Analyser<br />
ALG,UpM6001 AU<br />
Includes 3 x 1kA clip-on current transformers. Integral digital display and<br />
printer. Memory 512kb plus RS232 interface for data transfer. Measures<br />
each phase & total V, A, power, pF, VA, VAR. Measures demand over a<br />
defined interval, harmonic distortion, and provides FFT analysis. Records<br />
maxima and minima. Current inputs are at 1V or 5A for external CT’s.<br />
Voltage drop detection for durations exceeding 150ms. Software provides<br />
time plots and remote display of measurement parameters. Higher speed<br />
FFT harmonic plot possible up to 25th harmonic.<br />
Algodue UPM6100 Uni Power Meter 500Hz & Rogowsky 3kA<br />
Options<br />
ALG,UpM6100 AU<br />
power meter 3kA Rogowski current transducer (flexible CTs), 14~500Hz,<br />
harmonic distortion current and voltage 50th order. Large 4Mb memory.<br />
Algodue Ret Set of 3 Rogowski Transducer<br />
ALG,RET<br />
Use with the ALG,UpM6001. Ranges 300A/3kA. powered from analyser.<br />
> NEW Hioki 3197 Power Quality Analyser with 3x1000A<br />
Clamp-on CTs<br />
HIO,3197pQA AU<br />
Monitors inrush current, voltage swell, voltage dips, transient over-voltage<br />
and interruptions. Measure and records power and power factor, active/<br />
reactive energy, demand, load changes (with graph display), voltage and<br />
current. Measures impulsive voltage quality. RMS voltage quality, voltage<br />
swell, voltage dips & voltage interruption. Power quality, frequency, voltage,<br />
current, current peak, active/reactive/apparent power & power factor<br />
(displaced power factor). Three phase quality, voltage unbalance ratio,<br />
current unbalance ratio, harmonic quality (up to 50th order). Harmonic,<br />
voltage, current, ower, voltage/current phase angle. Total harmonic, voltage<br />
distortion, current distortion (THD-F, THD-R).<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 53
ELEC<strong>TR</strong>ICAL POWER<br />
54<br />
pOWer analySerS & recOrderS<br />
> NEW Hioki 3169-20 Clamp-On Power HiTester for Power<br />
Measurements<br />
HIO,3169-20CLAMpONpT AU<br />
Allows measurement of 1ph~3ph 4-wire circuits with a single unit. In<br />
addition to measuring standard parameters such as voltage, current, power,<br />
power factor, and integrated values, this unit can simultaneously perform<br />
demand measurements required for carrying out power management and<br />
energy-saving measures, as well as harmonic measurements. Features<br />
PC card data storage and comes equipped with an RS232C interface for<br />
PC communications. Can measure the power of just a few cycles, enabling<br />
more detailed and effective energy-saving measures. Supplied with Hioki<br />
9625 power measurement support software for data analysis. Measure up<br />
to 3ph, 3 wire system (displays voltage and current for 3 lines), up to 4 x<br />
1ph, 2 wire systems, 5A~5kA range, pC card data storage, power recording<br />
for individual waveforms. Simultaneous recording of demand values and<br />
harmonics. Applications are energy maintenance/control, energy control<br />
under ISO 14000, saving energy activities, power consumption measurement<br />
of specific device/equipment, harmonic analysis.<br />
> NEW<br />
HIOKI 3169-21 Clamp-On Power HiTester<br />
HIO,3169-21 CLAMpONpT AU<br />
Measure up to 3-phase, 3-wire system (displays voltage and current for<br />
three lines), Measure up to four single-phase, 2-wire systems, 5A~5000A<br />
range. Compact and light weight, PC card data storage, power recording<br />
for individual waveforms, simultaneous recording of demand values and<br />
harmonics. Main applications: energy maintenance/control, energy Control<br />
Under ISO 14000, saving energy activities, power consumption Measurement<br />
of specific device/equipment and harmonic analysis. Complete with RS232C<br />
interface for pC communications. Supplied with Hioki 9625 power<br />
Measurement Support Software for data analysis.<br />
Hioki 3196 3 Phase Power Quality Analyser<br />
HIO,3196-pQA AU<br />
High speed (0.5µs 2MHz) field unit. Channels 4 voltage, 150~600V rms 4<br />
ranges (isolated), 4 current 0~5kA (3ph and neutral) rms 2 ranges. Supplied<br />
with 4 x 5kA flexible clamp-on CTs (length 945mm). Memory 13Mb internal,<br />
512Mb compact flash card. Display internal high resolution colour LCD.<br />
Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to 50th<br />
order) flicker IEC6100-4-15. Total energy, tariffs, max demands, transient<br />
and sub-cycle disturbances. Software provides graphs and summaries to<br />
PC. Interfaces RS232 and 10base ethernet.<br />
> NEW<br />
Hioki 9670 Thermal Printing Method Printer, Input RS232C<br />
HIO,9670 pRINTER AU<br />
Uses stationary type, thermal printing method printer which prints date input<br />
via RS232C from a computer or the other host system. Convenient battery<br />
that makes easy to carry around. provides high-speed printing with very<br />
little noise. provides clear printing of 16 x 16 dots and 24 x 24 dots (as<br />
well as Japanese characters JIS Level I and II), and can print bar codes.<br />
provides various settings such as enlarged-character printing. Graphics can<br />
be printed using bit images.<br />
Hioki 9694 Clamp-on CT 5A<br />
HIO,9694CT5A AU<br />
Rated primary current 5A ac. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at<br />
45~66Hz), 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated<br />
wire. Core jaw 15mmØ. Size: 46w × 21d × 135hmm, cord length 3m.<br />
Hioki Clamp-on 100A ac CT<br />
HIO,9660CT100A AU<br />
Rated primary current 100A ac. Amplitude accuracy: ±0.5% rdg. ±0.2%fs (at<br />
45~66Hz). 66Hz~5kHz ±1% or less. Max circuit voltage 300V rms/insulated<br />
wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.<br />
Fluke 43 Power Quality Analyser<br />
FLU,43 NZ<br />
Single phase power quality analyzer. Combination power quality analyzer,<br />
multimeter and scope. Scope displays voltage and current waveforms.<br />
Measures true-rms voltage, current and frequency. Measures voltage,<br />
current, and power harmonics up to 51st harmonic. Total harmonic distortion<br />
(THD). Phase angle of individual harmonics. Continuously measure volts<br />
and amps on a cycle-by-cycle basis for up to 24h. Use cursors to read time<br />
and date of sags and swells. Supplied with 500A current probe, software<br />
and cable.<br />
Fluke 43B 1 Phase Power Quality Analyser<br />
FLU,43b NZ<br />
Combines the capabilities of a power quality analyser, scope and multimeter<br />
in a single easy-to-use instrument. EN 61010-1 CAT II, 600V. UL and CSA<br />
listed. Recording times 4min~16d (selectable).<br />
Megger PA9Plus Portable Power Quality & Demand Analyser<br />
MEG,pA9pLUS AU<br />
Integral graphic backlit LCD and compact flash card memory. Measures<br />
and records all voltage/current power and waveform activity. Input voltage,<br />
4 differential channels auto ranging between 20~300, 300~600V ac, V dc<br />
scales, accuracy ±0.25% of reading, ±0.05% of range to the 63rd harmonic.<br />
Crest factor voltage 3.5 limited to 1.5kV peak. Current 1.4 of full scale at<br />
peak input. Current 5 channels resolution 0.1% fs, accuracy ±0.25% of<br />
reading, ±0.05% of range to the 63rd harmonic. Frequency fundamental<br />
50Hz response dc to 3.15kHz (63rd harmonic). Resolution 0.01Hz. Sample<br />
rate 256/cycle current and voltage simultaneously. Harmonic distortion<br />
current and voltage to the 63rd order and THD. power supply 90~600Vac,<br />
50Hz, 100~600Vdc either via channel 1 or from independent IEC lead.<br />
Memory 12Mb internal, 512Mb compact flash card. Current sensors 4 x<br />
600~6,000A Rogowski flexible. Report generation software included. Setup<br />
and download can be done through RS232 or flash card.<br />
> NEW CCI Power-Mate 15A Single Phase Power/Energy<br />
Measurements<br />
CCI,pOWER-MATE 15A AU<br />
Can accurately measure and calculate power, volts, amps and energy being<br />
used by an electrical appliance. Also measures the greenhouse gas emission<br />
created by an appliance. Can determine the actual running cost, how much<br />
energy the appliance used in kilowatt-hours and how many kilograms of<br />
greenhouse gas emissions it produced all in hourly, yearly, quarterly and<br />
accumulated figures. Features an LED display for easy reading and high<br />
visibility at all times. 15-amp version - to a maximum continuous capacity of<br />
15A, but readings are accurate to 18A and the cable is rated to 15A. provides<br />
a variety of measurements including: power in watts, voltage and current.<br />
Provides the minimum, maximum as well as instantaneous readings.
NEW<br />
CHK Gridsense PM40 Power Quality Analyser<br />
CHK,pM40pQA<br />
Weatherproof Ip65 field unit. Channels: 3V, 63-440V (isolated). 4 current<br />
0 to 3,000A (3ph and neutral) rms. Supplied with 4 flexible 3,000A clampon<br />
CTs (flexible CT length 600mm and Diameter 190mm). (In addition,<br />
clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A<br />
for neutral conductor current measurement are available.) Memory: 15 Mb.<br />
Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V,<br />
A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current<br />
imbalance (THD and individual to 48th ) and Flicker. Total energy, tariffs,<br />
maximum demands, and transient and sub-cycle disturbances. Included<br />
software provides graphs and summaries to PC. Download files while<br />
logging USb interface. A pC using Windows 95, 98, NT4, WIN2000 or xp<br />
O/S, is required with the CHK powerView software to configure this unit<br />
before operating.<br />
pOWer analySerS & recOrderS<br />
GridSense CHK PM30 Plus 3 Phase Powermonic Logger/<br />
Logger<br />
CHK,pM30pLUS AU<br />
Weatherproof Ip65 field unit. Channels 3 voltage, 63-440V (isolated), 4<br />
current 0 to 3kA (3ph & neutral) rms. Supplied with 3 x flexible 3kA clampon<br />
CTs (flexible CT length 600mm & 190mmØ). Clamp-on CTs of 3kA,<br />
1kA for large conductors and 500A & 100A for neutral conductor current<br />
measurement are available. Memory 4 Mb. Inbuilt 2 line LCD display.<br />
Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to<br />
48th ). Total energy, tariffs, maximum demands, transient and sub-cycle<br />
disturbances. Software provides graphs and summaries to PC. Download<br />
files while logging via RS232 interface. pC using Win 95, 98, NT4, 2000,<br />
xp, O/S, is required with the CHK pOWERview software to configure this<br />
unit before operating.<br />
�������<br />
���������<br />
�������<br />
���������<br />
��������������������<br />
��������������������<br />
�����������������������������<br />
�����������������������������<br />
���������������<br />
���������������<br />
�������� ����<br />
the latest addition to the rugged, weatherproof and versatile<br />
powermonic range has ��� ��� ��� ���<br />
features including:<br />
• flicker monitoring<br />
• interharmonics<br />
• voltage unbalance<br />
• increased memory capacity (15mb)<br />
• larger lcd display<br />
• real-time data display<br />
• compliance to all iEc pq standards<br />
• high-speed usb data transfer<br />
Other features include:<br />
for more information visit - http://www.gridsense.net�<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
• tables & graphs of 3 phase v,a, pf,dpf, kw, kva, kvar, thd,<br />
harmonic phase angle, individual harmonics, interharmonics,<br />
frequency, all to iEc standards<br />
• total Energy & tariffs calculator<br />
• ability to capture motor starts, high speed rms & waveform<br />
disturbances<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 55
ELEC<strong>TR</strong>ICAL POWER<br />
56<br />
pOWer analySerS & recOrderS<br />
CHK PM30 3 Phase Powermonic Power Logger<br />
CHK,pM30 AU/NZ<br />
Weatherproof Ip65 field unit. Channels 3 voltage, 63~440V (isolated), 4<br />
current 0~3kA (3ph & neutral) rms. Supplied with 3 x 1kA clamp-on CTs<br />
(cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors<br />
and 500A & 100A for neutral conductor current measurement are available.<br />
Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA,<br />
kVAr, kW, harmonics, (THD and individual to 48th ). Total energy, tariffs,<br />
max demands, transient and sub-cycle disturbances. Software provides<br />
graphs and summaries to PC. Download files while logging via RS232<br />
interface. pC using Win 95, 98, NT4, 2000, xp, O/S, is required with the<br />
CHK POWERview software to configure this unit before operating.<br />
CHK PM20 Power Quality Analyser/Logger<br />
CHK,pM20 AU<br />
Three phase, weatherproof Ip65 field unit. Three voltage channels 63~440V<br />
(isolated). Four current channels 0~3kA rms (3ph & neutral). Supplied with<br />
3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and<br />
500A for neutrals clamp-on CTs are available. Memory 4Mb. In-built 2 line<br />
LCD display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and<br />
tariffs, high speed rms waveform capture events outside preset limits (10ms<br />
intervals). Software provides graphs and summaries to PC. Download<br />
files while logging. RS232 interface. pC using Win 95, 98 or NT4 O/S, is<br />
required with the CHK POWERview software to configure this unit before<br />
operating.<br />
CHK 3 Phase Converter for CTs 1A Input to 200mA Output<br />
CHK,CK1 AU<br />
Adaptor for CTs with 1A secondary outputs, this unit suits CHK,pM30/20.<br />
External Modem 56k Remote Communication for CHK,PM30/<br />
PQA<br />
CHK,MODEM-56K AU<br />
External modem 56k for CHK pM20, CHK pM30, CHK pM30pLUS or any<br />
other power quality analyzer. Modem gives remote access control to setup/download<br />
any connected Instrument.<br />
CHK 3 Phase Converter for CTs 5A Input to 200mA Output<br />
CHK,CK5 AU<br />
Adaptor for CTs with 5A secondary outputs, unit suits CHK,pM30/20.<br />
CHK CR100 Clamp-on CT<br />
CHK,CR100 AU<br />
Jaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to<br />
measure neutral current. Accuracy Class 1.<br />
CHK CR500 Clamp-on 500 CT<br />
CHK,CR500 AU<br />
Jaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to<br />
measure neutral current. Accuracy Class 1.<br />
CHK CT1000L Large 1kA Primary Clamp-on CT<br />
CHK,CT1000L AU<br />
Large 123 x 35mm 1kA primary clamp-on CT for CHK,pM20/30.<br />
Gridsense 3000 Amps Flex CT 600 mm<br />
CHK,CT3000 pLUS AU<br />
CHK CT3000L Large 3kA Primary Clamp-on CT<br />
CHK,CT3000L AU<br />
Large 123 x 35mm 3kA primary clamp-on CT for CHK,pM20/30.<br />
Metrix MX200 ac/dc Clip-on Power Meter<br />
MET,Mx200 AU/MY<br />
Ranges 19.99 & 199.9A. Measures voltage to 750V, frequency to 999Hz,<br />
power 1.99 & 19.99kW, apparent power 1.99 & 19.99kVA, & pf. Recorder<br />
output via special leads (supplied) for current range only, 5mV/A on 199.9A<br />
range. Switch in battery compartment gives ac as well as dc output. Internal<br />
battery for 70h operation. Clamp capacity 23mmØ or 20 x 10mm bars.<br />
Metrix MX2040 ac/dc Clamp-on Meter<br />
MET,Mx2040 AU/NZ<br />
Measures A, V, Hz, kW, kVA, kVAR, kWH, pF and resistance. Ranges 200A<br />
& 2kA, 600V & 1kV, 20, 200kW & 2MW & kWH. Scale length 3,000. 1 &<br />
3ph operation. Motor rotation indication. peak, min, max, average, rms, and<br />
crest factor indication. peak response time 1µs. Analogue output option<br />
fitted giving dynamic signals and calculated parameters (energy, etc).<br />
Martindale Phase Sequence & Continuity Indicator 100~600V,<br />
50/60Hz<br />
MAR,pSCI424-585 AU<br />
Tester may be used, on 3ph circuits, to check the presence & sequence<br />
of the phases. Important on motor circuits as a phase reversal will cause<br />
a motors direction to reverse. Tester will give visual indication of loss of<br />
phase or an incorrect sequence. Tester is supplied in 2 forms - probe style,<br />
the connection to the tester is via 3 insulated cables to 3 fused test probes,<br />
1 with an insulated crocodile clip. plug style, a 16A, 4 pin, 3ph & earth,<br />
bS4343 plug is fitted to the tester. Use as a socket tester prior to plugging<br />
in 3ph equipment. Testers supplied in a plastic wallet, with full instructions.<br />
Caution, the unit should be checked for correct operation using a known<br />
voltage before use.<br />
Yokogawa CW140 Demand/Harmonics Analyser<br />
YEW,CW140 AU/NZ<br />
Includes 4 x 500A clip on current transformers, jaws 30mmØ inside. Current<br />
transformers are accurate at currents of
NEW<br />
Omicron CPC 100 PTS for CTs/VTs/Power Transformer<br />
OMI,CpC100pTS AU<br />
Allows for automated testing of power transformers, CTs, VTs, resistance<br />
testing, and more. providing up to 800A (or 2000A with current booster) and<br />
2000V and comes complete with an integrated PC. Its software routines test a<br />
wide range of substation equipment, and automatically creates customizable<br />
reports. Weight: 29 kg. Analog voltages and currents can be measured with<br />
very high precision. Its Ohm meters automatically switch ranges from µOhm<br />
to kOhm to allow for a wide variety of applications. Testing of unconventional<br />
equipment, such as Rogowski Coils or current sensors completes the<br />
spectrum. Safety features: emergency shut off button, safety key lock (block<br />
unauthorised use).<br />
Omicron CMC156-3 Advanced Protection Relay Test Set<br />
OMI,CMC156-3 AU<br />
For three-phase testing of relays, meters and transducers, for applications<br />
requiring portability. • 3 x 125V outputs, • 3 x 12.5A outputs, • 6 x low level<br />
outputs (rear side), • 2 x counter inputs (rear side), • 4 x binary outputs, •<br />
dc measuring inputs, • 10 x binary inputs. Applications are digital distance<br />
relay testing or testing of transformer operated energy. Signal generation<br />
is performed digitally. The 16-bit D/A conversion results in a high quality<br />
signal event at small signal amplitudes. In addition to the 6 outputs of the<br />
amplifier section, 6 independent channels with low-level signals are available<br />
at the back of the unit which can be used to control external amplifiers for<br />
applications requiring more than 3 voltage or current phases, e.g., testing<br />
of differential relays, or applications requiring higher currents or voltages.<br />
They are also useful where there is a need for output power higher than that<br />
provided by the CMC 156. Comes with Test Universe 2.01 software loaded<br />
on dedicated laptop. Weighs 9.8 kg.<br />
Omicron CMC256-6 EP Advanced 3Ph Protection Relay Test<br />
System<br />
OMI,CMC256-6 Ep AU<br />
Current integral 3ph current source max 140VA, 6 output sources, resolution<br />
500µA, suitable for most relay types, including some high burden units.<br />
Voltage 3 ph voltage 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay<br />
monitoring trip, monitoring 6 isolated inputs, can be configured to be voltage<br />
free or 0~250V. Contact outputs 6 isolated change-over relay contacts<br />
(software controlled). Max 250V ac 10A or 125V dc 1A. Interface connector,<br />
16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated<br />
analogue inputs ±500V peak max 12 bit resolution. Input supply 90~260V<br />
dc, 400Hz. Intuitive on-line help. Notebook 486 or better Win 3.11, 95, 98 or<br />
NT, display SVGA or better. Interface parallel port.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
prOtectiOn relay teSting SyStemS<br />
Omicron CMGPS Syncronisation Control Unit<br />
OMI,CMGpS AU<br />
GpS-based synchronisation unit, which is used to synchronise CMC<br />
(protection Relay) test sets. Used when performing end-to-end tests of<br />
line protection schemes, the unit provides a start signal pulse based on the<br />
GpS clock time base. Software is both integrated in the testing modules<br />
(State Sequencer) and can also be used as a stand-alone application. Two<br />
independent timing pulses are available via separate connectors, on a 16pin<br />
plug (pulse out 1) which is connected with the CMC test set (external<br />
interface) and on 2 x 4mm banana plugs (pulse out 2). Supplied with GpS<br />
antenna, 15m antenna ext cable, plug-in power supply, CMC-CMGpS<br />
interface cable, users manual, fabric carry bag and a travel case. Weighs<br />
5kgs.<br />
Omicron C-Probe-1 Clamp-on CT ac/dc<br />
OMI,C-pRObE1 AU<br />
An active ac & dc current probe with voltage output. Recommended<br />
accessory for measuring currents with the CMC 256. Two measuring ranges:<br />
10A & 80A. Frequency range dc 10kHz. Accuracy error < 2% for currents up<br />
to 40A and frequencies up to 1kHz. phase error < 0.5O @ 50/60Hz. Length<br />
230mm.<br />
Omicron CMC256-6 Advanced Protection Relay Test Set<br />
OMI,CMC256-6 AU<br />
Advanced 3ph dynamic automatic protection relay test system. Current,<br />
integral 3ph current source max 140VA, 6 output sources, resolution 500µA,<br />
suitable for most relay types, including some high burden units. Voltage,<br />
3ph 0~300rms. Auxiliary dc supply, 0~264V, 0.2A. Relay monitoring trip,<br />
monitoring 6 isolated inputs, can be configured to be voltage free or 0~250V.<br />
Contact outputs 6 isolated change-over relay contacts (software controlled).<br />
Max 250Vac, 10A or 125Vdc 1A. Interface connector, 16 TTL digital inputs<br />
and outputs. Scope analogue inputs, 2 isolated analogue inputs ±500V<br />
peak max 12 bit resolution. Input supply 90~260Vdc, 400Hz. Intuitive online<br />
help. Laptop and Test-Universe software up to TU V 2.01 supplied with<br />
test set, interface parallel port.<br />
Programma Sverker 760 Relay Test Set<br />
pRO,SVERKER760 AU<br />
Relay test set for 1ph protective relay equipment. Three phase relays can<br />
be tested 1 phase at a time or by synchronising more than one unit. Current<br />
ranges to 100A with full load current to 250A. AC outputs to 250V & dc<br />
outputs to 300V. In-built capacitor and resistors for current output phase<br />
shifting (360 0 ). In-built timer, ammeter, and voltmeter. Measures phase<br />
angle, PF, and impedance. RS232 communications and control interface.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 57
ELEC<strong>TR</strong>ICAL POWER<br />
58<br />
prOtectiOn relay teSting SyStemS<br />
T&R DVS3-HP Static Relay Test System<br />
T&R,DVS3-Hp AU<br />
Test system for testing voltage and frequency protection relays and<br />
transducers. Tests Automatic Voltage Regulating (AVR) relays with line drop<br />
compensation, under and over voltage relays, directional over~current relays,<br />
df/dt (ROCOF) relays, vector surge (step change of phase) relays and check<br />
synchronising relay. Generates a 3ph voltage output from a 1ph supply,<br />
and may be used in conjunction with a current source to test directional<br />
protection. Requires 1ph 50/60Hz supply of 115V or 230V (±15%). Unit<br />
automatically selects the correct range. Max power requirement of the unit<br />
is 0.5kVA. DVS3-Hp has 3ph star connected output and the rating of each<br />
phase is:- voltage 0~133V phase to neutral, current 5min on/15min off 330mA<br />
@ 133V, or 200mA continuous, phase lock 45Hz~65Hz., variable frequency<br />
40~999.9Hz., variable phase angle ±180 O . Delta loads may be connected<br />
directly to the output or through the DVS-T VT box. Max voltage obtainable<br />
is 133V between any phase & neutral and 266V between 2 phases (if the<br />
phase angles of the 2 phases are set to 180 O apart). DVS-T VT box may be<br />
used to double these output voltage (Ratio 1:2).<br />
Get more done.<br />
> NEW<br />
Programma EGIL Circuit Breaker Analyser<br />
pRO,EGIL-Cb ANALYZER AU<br />
One main contact per phase. Three time channels are connected together<br />
on one side. Events at parallel contacts equipped with pre-insertion resistors<br />
are recorded and displayed simultaneously. Two separate time channels<br />
for measurement of auxiliary contacts. On-site hookup comes with readymade<br />
multi-cable sets for both main and auxiliary contacts. Coil currents<br />
are measured automatically, presented together with other readings<br />
immediately after testing on the display window or via the built-in printer. A<br />
built-in sequencer (program unit) sets the instrument automatically for the<br />
next sequential breaker operation. Intended primarily for measuring travel<br />
(motion). Can be equipped with an optional serial interface (RS232C) for<br />
communication with a pC and the CAbA Win breaker Analysis Software.<br />
More tools for commercial and plant technicians.<br />
Get the job done faster and more accurately with Fluke’s innovative set of tools for electrical<br />
test. From IR thermometers to clamp meters, every rugged tool delivers the reliabilty, accuracy<br />
and safety you expect from Fluke.<br />
Power Quality compliant load studies, energy consumption<br />
testing and general power quality logging.<br />
Verify your power. The Fluke 1735 Power Logger is the ideal technician’s tool for conducting<br />
30-day load studies.<br />
• Set up in seconds<br />
• Measure all 3 phases and neutral<br />
• Log most electrical parameters, plus harmonics and voltage events<br />
More information and resources.<br />
You can always count on Fluke for the troubleshooting techniques, application information, and<br />
training to keep your electrical systems up and running.<br />
Fluke. Keeping your world<br />
up and running.<br />
Power Quality<br />
Analysers<br />
Earth Ground<br />
Testers<br />
Fluke Australia Pty Ltd.<br />
Phone: (02) 8850 3333<br />
Fax: (02) 8850 3300<br />
Email: sales@fluke.com.au<br />
©2006 Fluke <strong>Corporation</strong>. All rights reserved. Ad 01981<br />
Insulation Testers Thermal Images
High Voltage Test Set 30kV/50 Hz AC Hi Pot Tester<br />
HIV,pFT303 AU<br />
Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA<br />
1/2 hours on 2 hours off, at 2 kVA 1 hour on 1 hour off. For a field and repair<br />
shop HV testing applications. Tests the integrity of items including insulating<br />
materials, isophase bus duct, switchgears, transformers, vacuum bottles &<br />
interrupters, vacuum switches, automatic circuit reclosers, bushings, fuses,<br />
arrestors, circuit breakers, transformers, capacitors, motor and generator<br />
windings.<br />
High Voltage PFT503, 50kV ac Test Set<br />
HIV,pFT503 AU<br />
Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA<br />
½h on 2h off, at 2kVA 1h on 1h off.<br />
High Voltage Inc Very Low Frequency (VLF) 6022 60 kV Hi-pot<br />
Test Set<br />
HIV,VLF6022 AU<br />
For field testing of ac high/medium voltage cables, bushings, and insulators.<br />
Input 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0~60kV ac<br />
peak, frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance<br />
1.1µF (approx 3kms of cable at 0.1Hz), 2.2µF (approx 9 of cable at 0.05Hz)<br />
& 5.5µF (approx 13kms of cable at 0.02Hz). Display 0~60 peak kV.<br />
Interconnect cable length 3m, control unit to HV transformer. RG8/U output<br />
cable length 3m. Shorting stick braid 6m. HV tank and control units shipped<br />
in travel cases weighing 70 & 40 kgs respectively.<br />
Baur PGK80 High Voltage (80kVDC) Insulation Tester<br />
bAU,pGK80 AU<br />
Max output 80kV at 0.8mA. In-built timer, zero start interlock and automatic<br />
discharge device.<br />
Megger FT6/12 Ionisation, Leakage and Breakdown Tester<br />
MEG,FT6/12 AU/MY<br />
AC ranges 0~2kV, 0~6kV, dc ranges 0~4kV, 0~12kV. Output currents<br />
7.4mA, 8.9mA ac & 2.1mA, 2.5mA dc. breakdown and flashover indication<br />
by latching indicator for periods exceeding 1ms. Current threshold<br />
100µA~1mA. Ionisation indication by internal speaker. Meter indication of<br />
ac, dc and ac capacitive currents. Complete with probes.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
hi pOt teSterS<br />
T&R kV30-40, 30kV ac Hipot Test Set<br />
T&R,KV30-40 AU<br />
0~30kV, max output 40mA with a duty cycle of 5min on & 15min off. Max<br />
continuous current 20mA. Overload trip may be set from 4~44mA. Zero<br />
interlock and key operated safety features.<br />
High Voltage Test Set VLF 90 Kv<br />
HIV,VLF90 AU<br />
Very low frequency (VLF - 90 CM) ac hipot test set with 90kVac peak output,<br />
is suitable for testing cables up to 50kV. High load capacity enables it to test<br />
up to approx 7 miles of cable, depending on type. Model includes a charging<br />
current and load capacitance meter, test dwell timer, and polarity indicating<br />
lights. Output voltage & frequency,- sinusoidal 0~90kVac peak & selectable,<br />
0.1, 0.05,0.02Hz. Test frequency and rated loads with approximate cable<br />
lengths are:- 0.1Hz/0.55µF 1,673m of cable, 0.05Hz/1.1µF 3,353m of cable,<br />
0.02Hz/2.2µF 6,706m of cable. Kilovoltmeter scaled 0~100kVac peak,<br />
ammeter scaled 0~100mAac & 0~6µF load capacitance. Weight of the unit<br />
167kgs. HV Cable output is 6m flexible, shielded x-ray with alligator clamp,<br />
inter connect cable length 3m, shorting stick 6m lead with clip.<br />
High Voltage Inc VLF 4022 40kV Hi-pot Test Set<br />
HIV,VLF4022 AU<br />
For field testing of ac medium voltage cables, bushings, and insulators.<br />
Consists of control unit and HV tank. Input: 230V, 50Hz, 6A peak, 2.5A<br />
average. Output sinusoidal, 0~40kVac peak, frequency 0.1, 0.05 & 0.02Hz.<br />
Duty continuous. Test load capacitance 1.1µF (approx 3kms of cable at<br />
0.1Hz), 2.2µF (approx 9kms of cable at 0.05Hz) & 5.5µF (approx 13kms<br />
of cable at 0.02Hz). Display 0~40 peak kV. Interconnect cable length 3m.<br />
RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control<br />
in travel cases weighing 50 & 35kgs respectively.<br />
Danbridge Type JP30A Insulation Tester<br />
DAN,Jp30A AU/NZ<br />
DC high voltage insulation tester. Output voltage 0~3kV, 0~10kV, 0~30kV,<br />
in 3 ranges. Max output short circuit 2µA. Audible indication of ionisation.<br />
Current and voltage meters which may be used to calculate resistance.<br />
Megger BM80 Insulation Tester<br />
MEG,BM80 NZ<br />
Analogue/digital insulation and continuity tester. Insulation test voltages are:<br />
50, 100, 250, 500, 1,000Vdc. Resistance resolution is 0.01 MΩ. Voltage<br />
range is 0~600Vac.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 59
ELEC<strong>TR</strong>ICAL POWER<br />
60<br />
electrical tranSducerS<br />
Model Type Input Type (V) Input Ranges Output (V)<br />
CAT,CL-8-36 pH STICK Indoor two-pole tester 2~36kV<br />
MEG,DH2-6M Duplex handspikes for 10AmΩ meter 30Vac/dc 20A max.<br />
HIO,9661-01<br />
500A<br />
Clamp-on sensor<br />
HIO,9669-CCT-1000A 1,000A<br />
HIO,9667-FCT-5000A Flexible clamp-on sensor 500A/5,000A<br />
UNI,p75-3C HYbRID-Dp<br />
2Vac/dc 7,5000A/1.5V<br />
500-mVac<br />
HIO,3290CLAMpONAC/DC Clamp-on<br />
dc to 15kHz 2840A peak 1mV/A<br />
CHK,CR100S 100A<br />
LEM,CURRENT pRObE10A<br />
YEW,3228-11 High sensitivity clamp-on ammeter ac/dc current 50mA, 20A ac/dc 0~100mV ac/dc<br />
ALG,C173<br />
High sensitivity clamp-on ammeter & earth<br />
leakage<br />
Algodue only 0.001 ~ 1,000A 1mV~1V/A<br />
HIO,3128 Clamp-on ammeter ac current 15A, 1.5kA 0~200mV dc<br />
HIO,3285<br />
200A, 2kA, 1kHz 0~1 ac/dc, 0~1 V<br />
bEL,CG-120A 50, 500A 0 ~ 0.5 ac/dc<br />
ac/dc current<br />
UNI,p75-3C Current clamp<br />
4, 7.5kA 0~2/ 0~1.5 ac/dc<br />
HIO,3109 100, 250, 500,1kA 0~1 dc<br />
CHA,D35N<br />
1, 2, 3kA 0~5A ac<br />
FLU,80I,100S 0~10, 0.5~100, 5~1000A 1mA/A<br />
YEW,2215 Current shunt<br />
ac current<br />
1A, 1kA 0~50mV ac<br />
JR,CT-005 ac current dc volts 1, 2, 5kA 0~1dc<br />
ROb,543<br />
Rogowski coil<br />
1A ~ 2MA 0~2 ac<br />
LEM,LEM-FLExII 30, 300, 3kA 0~3 ac<br />
LG,FIC-51E True RMS transducer<br />
500V 0~5 dc<br />
<strong>TR</strong>,M05 Instrument transformer ac voltage<br />
100V, 500V rms 0~5 ac rms<br />
YEW,2261-01 Med voltage transformer (3.3kV) 220, 440V,2.2, 3.3kV 0~110 ac<br />
MOR,FDT<br />
0~20ac 50~1.6kHz 1~5 dc<br />
CI,253/50<br />
0~1mA<br />
Frequency transducer<br />
240 ac 45~55 Hz<br />
CT,891040-240 0~10 V dc<br />
CT,891040-110 110 ac 55~65 Hz 0~10 V dc<br />
CWE,230V Transducer ac voltage 230V 1mV/1V<br />
CAR,3-<strong>TR</strong>ANS Converter ac current 5A 0~10V dc<br />
> NEW CATU C-8-36 Phasing Stick-Two pole Phase<br />
comparator for Indoor Use<br />
CAT,CL-8-36 pH STICK AU<br />
Detect differences in voltage between any 2 points of an installation indicated<br />
by LED’s. Enables assessment of the residual voltage induced by nearby<br />
live lines or circuits, and differentiates it from the one provided directly from a<br />
high voltage source. Features, range of voltages 2kV~36kV, high luminosity,<br />
compact 0.62m with probes dismounted, high dielectric quality insulating<br />
material, 2 x 1.25m elements with removable probes, connected via a highinsulation<br />
lead, max use distance 2.25m (with probe extenders), operation<br />
testing with a checking device.
NEW<br />
Megger DH2-6 Test Lead, 6m long for 10A mΩ Meters<br />
MEG,DH2-6M AU<br />
Duplex handspikes (2) with spring loaded helical contacts test lead suitable<br />
for any 10AµΩ meters (like MEG,DLRO10, MEG,DLRO10x, CRO,DO7<br />
and CHK,LMO5), Used for 4 terminal measurements with low resistance Ω<br />
meters, double, individually sprung, hardened and nickel plated, spike prods<br />
for good contact. potential lead and spike marked for easy identification,<br />
suitable for use in potentially corrosive conditions. Body moulding resistant<br />
to aviation “phosphate ester” fluids. Current rating: 20A max. Working<br />
voltage: 30Vac/dc. Resistance of leads: each lead 20mΩ maximum.<br />
> NEW<br />
Hioki 9661-01 CCT-500A Clamp-on Sensors<br />
HIO,9661-01 CCT-500A AU<br />
500A rated, 500mVac fs output, jaw 46mmØ. Rated input current 500Aac,<br />
rated output current 0.5Vac, accuracy (at 45~66Hz). Amplitude ±0.5%rdg,<br />
±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency<br />
characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous<br />
550 Arms (45~66Hz), max circuit voltage 600Vac rms (insulated wire).<br />
Dimensions 77w x 151h x 42dmm, cord 3m. Suitable for Hioki models:<br />
3196pQA, 3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any<br />
data logger/scope which takes up to 1.7mVac input.<br />
> NEW<br />
Hioki 9669-CCT-1000A Clamp-on Sensors<br />
HIO,9669-CCT-1000A AU<br />
Jaw 55mmØ, 80mmx20mm busbar. Rated input current 1000Aac, rated<br />
output current 0.5Vac, accuracy (at 45~66Hz) amplitude ±1% rdg, ±0.01%<br />
fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics<br />
66Hz~5kHz (±1%), max. Allowable input continuous 1000A rms<br />
(45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions<br />
99.5w x 188h x 42d mm, cord 3m. Suitable for Hioki models 3196pQA,<br />
3197pQA, 3169-20CLAMpONpT, 2331-20RpMS, 8715-01, any data<br />
logger/scope which takes up to 1.7mVac input.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
electrical tranSducerS<br />
> NEW<br />
Hioki Flexible Clamp-on Sensor<br />
HIO,9667-FCT-5000A AU<br />
10Hz~20kHz, 500/5000A rated, 500mVac fs output, jaw 254mmØ max.<br />
Rated input current 500Aac, 5000Aac, rated output current 0.5 Vac, accuracy<br />
(at 45~66 Hz). Amplitude ±2% rdg ±1.2mV, fs is the 3196 range value.<br />
phase ±1° or less. Frequency characteristics 10Hz~20kHz max. Allowable<br />
input continuous 10000Arms (45~66 Hz) max. Circuit voltage 1000Vac rms<br />
(insulated wire). Dimensions 254w x 86h x 30dmm. Sensor length 910mm.<br />
Suitable for Hioki models: 3196pQA, 3197pQA, 3169-20CLAMpONpT,<br />
2331-20RpMS, 8715-01, any data logger/scope which takes up to 1.7mVac<br />
input.<br />
> NEW Universal Technic Clamp-On AC/DC Current Probe<br />
4000/7500A<br />
UNI,p75-3C HYbRID-Dp AU<br />
Ranges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and<br />
external power supply, 3V operation. Safety sockets 4mm. Clamp is<br />
suitable for use with any instrument with an input range of 2Vac or dc, and<br />
an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders,<br />
oscilloscopes, and power quality analysers.<br />
> NEW<br />
Hioki 3290 Clamp-On ac/dc HiTester<br />
HIO,3290CLAMpONAC/DC AU<br />
Current Measurement at dc and from 1Hzac~1000Hz. Current Clamp<br />
Hioki 9693 Clamp-on ac/dc sensor ranges - 20, 200 & 2000A, jaw opening<br />
55mm.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 61
ELEC<strong>TR</strong>ICAL POWER<br />
62<br />
electrical tranSducerS<br />
> NEW<br />
CHK,CR100s Clamp-On CT 100A<br />
CHK,CR100S AU<br />
Suitable for CHK power quality analysers like CHK pM20, pM30, pM30 plus<br />
and pM40.<br />
> NEW<br />
HK,CR200 Clamp-on CT 200A~200mA, 2.2Ω Burden Class I<br />
CHK,CR200 AU<br />
CT 200A~200mA, 2.2W burden Class I, IEC 185-1987. Suitable for any of<br />
the CHK powermonic power Quality Analyser like CHK,pM20, pM30 and<br />
pM30 plus units. Suitable for power cables size diameter up to 50mm.<br />
> NEW<br />
LEM Current Probe 10A~1A for LEM,TOPAS 1000 PQA<br />
LEM,CURRENT pRObE10A AU<br />
Current probe 10A~1A suitable for LEM Topas 1000 power quality analyser.<br />
> NEW<br />
Cambridge Frequency Transducer 45~55Hz 240Vac<br />
CT,891040-240 AU<br />
Frequency transducer from 45~55Hz with analogue output 0~10VDC.<br />
powered from 240Vac only.<br />
> NEW<br />
Cambridge Frequency Transducers 891040 55~65Hz 110Vac<br />
CT,891040-110 AU<br />
Frequency transducer for frequency from 55~65Hz with analogue voltage<br />
output 0~10Vdc. powered from 110Vac only.<br />
Algodue C173 Precision Clamp-on CT Microamps to 1Ka<br />
ALG,C173 AU<br />
High resolution clamp-on CT, for measuring differential and or earth loop or<br />
leakage current. Compatible with Algodue UpM6001 and the later UpM6100<br />
analyser’s fourth current channel. Current range 0.001~1.2, 0.01~12,<br />
0.1~120A & 1A~1.2kA. bandwidth 10Hz~3kHz. Max jaw opening 53mm.<br />
Bell CG-120A Current Gun (Clamp-on Probe)<br />
bEL,CG-120A AU<br />
Clamp-on hall effect current probe. For primary 0~500A ac or dc (two scales<br />
0~50 & 0~500). Frequency response dc to 1kHz. Output 0.5V full scale<br />
suitable for DMMs. Termination shielded 4mm banana plugs. Jaw opens to<br />
accept 19mmØ conductors. battery 9V alkaline typical life 100h.<br />
230Vac to 230mVdc Transducer<br />
CWE,230V AC NZ<br />
Interface with output to 4mm banana male plugs suitable for connecting to<br />
DMM or recorder. Input range: 200~255Vac. Output: 0~255mVdc.<br />
Carrel & Carrel 5A ac to 10Vdc Converter<br />
CAR,3-<strong>TR</strong>ANS NZ<br />
Three ac current to dc voltage transducers for use with 5A CTs and a<br />
recorder or logger. Input is 0~5Aac, output is 0~10Vdc. Accuracy is 0.5%<br />
between 1~5A at 50Hz.<br />
Fluke 1kA ac Current Clamp<br />
FLU,80I-1000S NZ<br />
Three ranges: 0~10A, 0.5~100A, 5~1,000A. Jaw opening is 55mm.<br />
HSI PSD Programable DC isolating interface<br />
HSI,PSD NZ<br />
Transmitter for industrial interfacing to chart recorders and loggers. Input<br />
ranges: 10mV~200V, 50µA~50mA. bi-polar output ranges: -1V, 0~2V, 0~5V,<br />
1~5V, 0~1mV, 0~2mV, 0~5mA, 1~5mA, 0~10mA 4~20mA. Accuracy: input/<br />
output 0.2%.<br />
Shimaden 4~20mA to 0~1V Isolating Interface<br />
SHI,20/0-1 NZ<br />
Suitable for use with chart recorders, loggers and other devices requiring<br />
isolation from 4~20mA process signals.<br />
Hioki 3109 ac/dc Clamp-on Current Meter<br />
HIO,3109 AU<br />
Current meter with recorder outputs. In dc mode is a voltage waveform.<br />
Ranges 100, 250, 500A & 1kA. Measures to 2kA with reduced accuracy.<br />
Voltage range 10, 25, 50, 250 & 500 ac/dc. Accuracy 2.5%FSD. Recorder<br />
output 1V/FSD. Operates for 36h from dry batteries or via external ac.<br />
Hioki 3285 ac/dc Clamp-on Meter with Analog Output<br />
HIO,3285 AU<br />
Ranges 200A/2kA ac/dc. Measure volts, ranges 30, 300 & 600V ac/dc.<br />
Frequency ranges 10, 100Hz & 1kHz. Display LCD, counts max 2,500<br />
current, 3,750 voltage and 1,250 frequency. Output voltage 1V for 2,000<br />
count fs for each current range, can select Rec rms output, response time<br />
about 250ms rise time, fall about 500ms. Select Mon for waveform output.<br />
1V is produced for 1,000 count on full scale frequency range. Output not<br />
available for voltage measurements. Supplied with signal output cord, 4mm<br />
to BNC convertor, carry case and ac adaptor. Powered with internal 9V<br />
battery or ac adaptor.<br />
Yokogawa 3228-11 Clip-on Ammeter<br />
YEW,3228-11 AU<br />
High sensitivity, 9 ranges 50mA~20A. AC or dc operation. Frequency range<br />
40Hz~1kHz. battery operated. Analogue output at full scale 100mV rms.<br />
Landis & Gyr FIC-51E Voltage Transducer<br />
LG,FIC-51E AU<br />
AC voltage to dc voltage transducer. Max input 500V. Output voltage 1Vdc<br />
per 100Vac input.<br />
Tech-Rentals,M05 Instrument Transformer<br />
<strong>TR</strong>,M05 AU<br />
Permits monitoring of ac power lines with low input level instruments. Input<br />
100~500V rms. Output 1~5V rms. Distortion less than 0.5%. bandwidth<br />
40Hz~10kHz.
Hioki 3128 Clamp-on Current Transducer<br />
HIO,3128 AU<br />
Clamp-on current meter with recorder output. Ranges full scale 15A~1.5kA.<br />
Output 200mV dc full scale. Batteries not required. Output is intended only<br />
for low speed recorders.<br />
Yokogawa 2255-01 10A ~ 5A Current Transformer<br />
YEW,2255-01 AU<br />
Input 10Aac, output 5Aac, max circuit voltage 3.45kV, burden 15VA, accuracy<br />
1% of rated value, bus bar connectors.<br />
Yokogawa 2215 Current Shunt<br />
YEW,2215 AU/MY<br />
50mV output, available in range of 1A~1kA.<br />
Crompton 235/50 Frequency Transducer<br />
CI,253/50 AU<br />
Input 240V ac, 45~55Hz, output 0 ~1mA.<br />
Moore FDT Frequency to Volts Transducer<br />
MOR,FDT AU<br />
Input range 6.5~12.5kHz at up to 20V peak to peak. Output 5Vdc at<br />
12kHz.<br />
Yokogawa 2261-01 2.2kV Potential Transformer<br />
YEW,2261-01 AU<br />
3.3, 2.2kV, 440 & 220V primary to 110V secondary.<br />
Jacobs Radio CT-005 Current Transducer<br />
JR,CT-005 AU<br />
Range 5kA, 2kA & 1kA. 1V dc output. Transformer can be split in two to<br />
accommodate cable or bus 22 x 55mm.<br />
Phase Sequence Meter 110 - 600 volts 50 / 60 Hz<br />
KYO,pSM8031 AU<br />
KYO,8031 MY<br />
phase indicator with open phase checker and phase indicator designed to<br />
check the presence of open phase and also the phase sequence by rotating<br />
disk and lamps. Check a wide range of 3ph power source from 110~600V.<br />
Operational voltage 110~600Vac, time limit for continuous >500V within 5min.<br />
Frequency response 40~200Hz(ac 110~200V), 40~400Hz(ac 200~600V)<br />
safety standard IEC61010-1 CAT.III 600V pollution degree 2 withstand<br />
voltage 2.2kVac for 5s. Dimensions 106L × 75W × 40Dmm, weight 350g<br />
approx. Cord 1.5m(R: red S: white T: blue)<br />
Beha 5774E 3 Phase Sequence/Rotation Indicator<br />
bEH,5774E AU<br />
For determing the rotational direction and sequence of a 3ph supply.<br />
Necessary to pre-determine the correct rotational direction of 3ph motors.<br />
Kikisui PLZ1002W Electronic Load<br />
KIK,pLZ1002W AU/MY<br />
Voltage range 3~110V. Current range 0~200A. In-built oscillator provides<br />
for dynamic load testing by switching between two different load levels.<br />
Load current may be remotely controlled by voltage or resistance signals.<br />
Multiple units may be operated in parallel. In-built digital volt/current meter.<br />
For dc inputs only.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
electrical tranSducerS<br />
Universal Technic P75.3C dc/ac Amp Clamp<br />
UNI,p75-3C AU<br />
Max current 7,500A dc & ac peak. bandwidth 1KHz. Min range 1kA.<br />
Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size<br />
122 x 54mm or 100 x 64mm. Max cable size 83mm. battery 9V - life 100h.<br />
Output sockets 4mm. DC current gives dc output, ac current gives ac output,<br />
4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.<br />
Robinson 543 Linear ac Current Transducers<br />
ROb,543 AU<br />
Wide bandwidth and very wide dynamic range. Supplied with an open<br />
ended flexible coil of 3m length which may be wrapped around a very large<br />
conductor or power pole, etc. Frequency range 10Hz~10kHz with 1%<br />
accuracy. Current range for 1 wrap of coil 1A~2MA at 50Hz. phase error<br />
< 0.04deg. Min bending radius 60mm. External insulation is required for<br />
metallic conductor. Output voltage 2V rms ac waveform. Also dc rectified<br />
output. In-built digital display.<br />
LEM FLEXII 30, 300 & 3,000A Transducer<br />
LEM,LEM-FLExII AU<br />
Flexible wrap-around ac current transducer. Length 600mm. Ranges 30,<br />
300A & 3kA. Frequency response 1~20kHz. Accuracy 1%. phase error<br />
0.5O. Output 3Vrms @ full scale. Requires 3 units for 3ph. Designed for<br />
multimeters and oscilloscopes (4mm banana plug or bNC connectors) but can<br />
also be used with the DRA,808 (requires adaptor lead), or VOL,pM3000A.<br />
Other instruments may be attached providing the correct adaptor/transducer<br />
and connection is available. Operates for 100h from 2 x 9V batteries.<br />
electrical teSterS<br />
Biddle 550005 Turns Ratio Test Set<br />
bID,550005 AU<br />
Single phase (can be used on 3ph individual phase windings). Turns ratio<br />
0.001~129.999. Exciting current 0~1A. Accuracy 0.1%. Hand cranked<br />
operation.<br />
AVO Penta-Plus DMM Analyser<br />
AVO,pENTA-pLUS-DMM AU<br />
Multifunction meter for measuring 1 & 3ph volts ac, primary and secondary<br />
current, true and reactive power, amplitude and phase angle, and also<br />
frequency. Easily configured to measure the amplitude and phase angle<br />
between any 2 current or voltage inputs. Displayed simultaneously on a<br />
backlight graphic LCD screen. Internal memory records up to 60 test results.<br />
Logging via RS232C port. parallel printer port. Voltage 0~650Vac, 9 ranges<br />
with 0.1% resolution. Max 1kV. Current 0~100A ac in 11 ranges, with 0.1%<br />
resolution. phase angle 0~360O with 0.1O resolution. power true and<br />
reactive ±0-100kW & ±0~100kVAr. Frequency 45~65Hz. Timer 0~999.999.<br />
Line or battery operated, 3h continuous on full charge.<br />
Metrix MX120 Multicore Clamp-on Meter<br />
MET,Mx120 AU<br />
Measures current in 1, 2, or 3 wire cables. No need to split cables or remove<br />
covers. Ranges 2 or 3 wire 0~40A, 1 wire 0~199.9A resolution 0.1A.<br />
Accuracy 5% with 2 or 3 wire oval or flat cable, 12% with round cable, 1.5%<br />
with single wire. battery operated. Display 3½ digit.<br />
Hioki 3282 Clamp-on Hi Tester (V, I, Hz & T)<br />
HIO,3282 AU<br />
Measures True rms, peak, min/max & hold. Ranges auto/manual, current<br />
30A, 300A & 1kA rms. Voltage 300/600V (1kVmax). Resistance 1/10kΩ.<br />
Frequency 40~100Hz & 66Hz~1kHz. Jaw capacity 46mmØ (50mm opening).<br />
Battery life approx 1.5h continuous.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 63
PCU1-SP and PCUI-LT<br />
Primary Current Injection Systems<br />
www.maceyselectrical.com<br />
Features<br />
PCU1-SP and PCU1-LT<br />
• 5kA maximum output current<br />
(higher overload currents for 2s)<br />
• Multi-function digital timing system<br />
• Digital true RMS memory ammeter<br />
• Solid state switching<br />
• 2000A and 5000A loading units<br />
• Three range outputs on loading units<br />
• Rugged, compact design<br />
• Optional trolley mounting of system<br />
PCU1-SP Additional Features<br />
• Secondary injection up to 100A<br />
• Direct reading CT ratio and polarity
electrical teSterS<br />
Hioki 3283 Clamp-on Leakage Current Tester<br />
HIO,3283-LEAKAGE-TES AU<br />
Analyser functions for filtering and output signals. Wide bandwidth<br />
5Hz~15kHz, high sensitivity with a full scale of 10mA, ranges 10mA, 100mA,<br />
1A, 10A & 200A primary. Resolution 10µA, high accuracy at ±1%,True rms<br />
measurement. Output monitor and record modes, ac/dc output 1~2V full<br />
scale. battery 9V approx 40h.<br />
current injectOrS<br />
SMC PET-100-C Secondary Current Test Set<br />
SMC,pTE-100-C AU/NZ<br />
AC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A &<br />
10V/100A. Additional outputs ac voltage 0~220V at 1A (4A 1min), dc voltage<br />
0~350V at 0.7A (2.8A 1min), dc voltage 0~250V at 0.25A, fixed 110V ac at<br />
0.3A. Timer 1ms~99,999s. Additional functions include measurement of<br />
the phase angle between the voltage and the current output tap selected,<br />
and the measurement of the impedance of the load connected in the current<br />
output taps.<br />
Multi-Amp MS-2 High Current Test Set<br />
MUL,MS-2 AU<br />
Designed to test overload relays, circuit breakers and earth fault trip devices.<br />
Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A,<br />
24V/25A, 6V/120A & 3V/240A. Short term over current of several times the<br />
rated current ranges is possible. Digital current meter has read and hold<br />
facilities for short duration currents. Digital timer measures elapsed time<br />
between energisation and the test device operating.<br />
> NEW T&R PCU1-SP with CT Ratio/Polarity and NLU5000A<br />
Loading Unit<br />
T&R,pCU1-Sp NLU5000A AU<br />
Medium powered primary current injection system. Features 5kA maximum<br />
output current (higher overload current for 2s). Multi-function digital timing<br />
system. Digital true RMS memory ammeter. Solid state switching. 2000A<br />
and 5000A load units. Three range outputs on loading units. Rugged,<br />
compact design. Optional trolley mounting of system. Secondary injection<br />
up to 100A. Direct reading CT ratio and polarity. May be configured to either<br />
give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V<br />
range or 1250A on the 9.2V range.<br />
T&R PCU1/E 2000 A Primary Current Test Set<br />
T&R,pCU1/E AU<br />
Comprises control unit and 2kA loading unit. Control unit includes timer,<br />
current and voltage meters, and variable output transformer. Current output<br />
to 100A at 5V ac, 50A at 10V ac. Voltage output to 25A at 240V ac. External<br />
loading unit output to 30A at 240V ac. Outputs 2kA at 0~3V, 1kA at 0~6V.<br />
Two units: weigh 35 & 45kg plus cables.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Equimp HT2035 Electrical Tester<br />
EQU,HT2035 NZ<br />
Complies with CEI 64-8 & CEI 64-4. Eight instruments in the one case which<br />
includes printer & RS-232C interface.<br />
Tests are:- 1. Low Ω range 0~20Ω, resolution 0.01. 2. 2 & 3 wire earth<br />
resistance measurement, range 0~1,999Ω. 3. Insulation resistance<br />
0~199.9MΩ, 250, 500 & 1,000V. 4. RMS ac 0~500V, resolution 1. 5. Short<br />
circuit loop impedance 0~1,999Ω, resolution 0.01. 6. Fault loop impedance<br />
measurement 0~1,999Ω. 7. Fault loop resistance 0~1,999Ω. 8. RCD<br />
tester.<br />
T&R 200 ADM Current Injection System<br />
T&R,200ADM AU<br />
Single phase portable current injection system with main and auxiliary ac,<br />
dc current and voltage outputs. Output ranges main voltage, 10, 35, 100<br />
& 240Vac & 240Vdc. Main current continuous, 1~25A, intermittent up to<br />
200A. Auxiliaries stabilised dc isolated and protected 1.04A @ 24V~0.11A<br />
@ 220V. Variable 300mA @ 0~130Vac. Resolution 100mV, 1mA, phase<br />
0.10. Timing range 0~999.999 with resolution 1ms. Metering LCD backlit<br />
true rms with a memory ammeter. Interface RS232. Protection main output<br />
duty cycle and auxiliaries, electronic thermal and fuse. Supply requirements<br />
1ph 115~230Vac 50/60Hz 2.3kVA max.<br />
T&R CIT/LU2000 Primary Current Injection Test Set<br />
T&R,CIT AU<br />
Comprises control unit and 2kA loading unit (LU). Control unit includes<br />
timer, current and voltage meters, and variable output transformer. External<br />
loading unit output 0~2kA, duty 5min on 15min off at 6V ac, continuous<br />
0~1kA at 3V ac. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets<br />
each 3m long. Control unit connects to LU with supplied interface cable.<br />
T&R 200A-3PH/ED 3 Phase Current Injection Tester<br />
T&R,200A3pHEDIT AU<br />
0~200A/phase output capacity. power supply 4 wire 5A/phase 3ph 240/415V.<br />
Typically 10A 5 pin 3 phase socket outlet HpM.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 65
ELEC<strong>TR</strong>ICAL POWER<br />
66<br />
pOWer line cOnditiOner/upS<br />
Model Type Capacity (VA)<br />
COM,T700UpS<br />
pOW,700VAUpS 700<br />
ApC,1102 1,000<br />
EAT,9120-2KVA 2,000<br />
Sb,0610-2000A 2,000<br />
Sb,0610-3000VA UpS<br />
3,000<br />
CHL,2200 2,200<br />
CHL,ACTIVE2000 2,000<br />
CHL,ACTIVE3000<br />
ApC,SU3000<br />
CHL,5000 5,000<br />
Sb,66-102-8<br />
2,000<br />
Conditioner<br />
Sb,210-26-725 2,500<br />
Sb,63-25-735 3,500<br />
HIO,bATTERYTEST Battery<br />
Sb.625-bATT battery pack<br />
> NEW<br />
Powerware 700VA/420W Line Active UPS<br />
pOW,700VAUpS AU<br />
protection in the 700~3000Va range. Input Voltage Range: 120/140/160-<br />
276 Vac. Frequency 45~65 Hz. plug and play tower, under monitor, or 2U<br />
rackmount. Line-interactive.<br />
Sola 66-102-8 2kVA Electronic Power Conditioner 2kVA<br />
Sb,66-102-8 AU<br />
Input voltage 240V +15% & -25%. Efficiency 94%. Distortion 0.5%.<br />
Sola 210-26-725 2.5kVA Power Conditioner<br />
Sb,210-26-725 AU<br />
Input range 240V ±40% for +5% & -8% regulation. Max distortion on linear<br />
loads 3%, on typical computer loads 5%. Efficiency 90%.<br />
Sola 0601-2000A 2kVA On-line UPS<br />
Sb,0610-2000A AU<br />
Sb,0610-2000VA NZ<br />
Run time 10min or 25min at half load. Novell/RS232 communications<br />
interface included providing relay contacts for mains failure and low<br />
battery, input for remote shut down, and RS232 send/receive, all via a Db9<br />
connector.<br />
APC Pro 1000 UPS<br />
ApC,1102 NZ<br />
1 KVA line interactive ups with built-in filters for sags, surges and transients.<br />
Switches to battery power in 20ms in the event of a power outage.<br />
Compaq On-line 700 Watt UPS<br />
COM,T700UpS NZ<br />
Eaton Corp Powerware 9120 2kVA Online UPS<br />
EAT,9120-2KVA NZ<br />
The double conversion online PW9120 with its wide input voltage is capable<br />
of working with mains power in most conditions without discharging batteries.<br />
Capacity 2kVA 12min IEC 10 A 5 Aust 10A 215 x 470 x 365 mm.<br />
Sola 625 Battery Pack<br />
Sb,625-bATT NZ<br />
Sola 625-3000VA On-line UPS<br />
Sb,625-3000VA NZ<br />
Output regulation is ±3%, run time at full load is 8min or 20min at half load.<br />
125% overload capacity for 10s.<br />
Sola Basic 3500VA 110V OP Power Conditioner<br />
Sb,63-25-735 NZ<br />
3500VA fero resonant power conditioner. 230V input and 110Vac output.<br />
Filters out sags, surges and transients.<br />
APC SU3000 3kVA On-line UPS<br />
ApC,SU3000 AU<br />
Run time 5min at full load. Network software included. Weight 60kg.<br />
Chloride Powerlan 2.2kVA UPS<br />
CHL,2200 AU<br />
Sinewave output. Dual pC interfaces. Typical run time 10min. Weight 43kg.<br />
Vigilant 7 network interfacing software included.<br />
Chloride Powerlan 5kVA UPS<br />
CHL,5000 AU<br />
Sinewave output. Dual PC interfaces. Typical run time 10min. Weight<br />
120kg. Vigilant 7 network interfacing software included.<br />
Chloride Active 2kVA Double Conversion UPS<br />
CHL,ACTIVE2000 AU<br />
Double conversion sinewave output. Dual PC interfaces. Typical run time<br />
20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V<br />
ac 1ph + N ±3%. Efficiency >88%. Dimensions 200w x 875d x 350hmm.<br />
Weight 81kg. MopUpS professional software for system monitoring and<br />
shutdown included. USb port & RS232 communication port for UpS<br />
monitoring and management.<br />
700<br />
3,000
Chloride Active 3kVA UPS<br />
CHL,ACTIVE3000 AU<br />
Double conversion sinewave output. Dual PC interfaces. Typical run time<br />
20min. Input (nominal) 2220/230/240V ac 1ph + N. Output 220/230/240V<br />
ac 1ph + N ±3%. Efficiency >90%. Dimensions 200w x 875d x 350hmm.<br />
Weight 81kg. MopUpS professional software for system monitoring and<br />
shutdown included. USb port & RS232 communication port for UpS<br />
monitoring and management.<br />
> NEW Dimmer Dot Variable AC Voltage Auto Transformer 3<br />
Phase 23~28A<br />
VAR,D-283-Ob AU<br />
Manual operated air cooled; Input 400/415V, 50Hz. Output 0~415/470V.<br />
23-28A. Total Weight 95kgs.<br />
Ferguson 115-2000 2kVA 240/115V Transformer<br />
FER,115-2000 AU<br />
Ferguson 115-1,000 240V 1kW Transformer<br />
FER,115-1000 AU<br />
240~115Vac, 1kVA stepdown transformer.<br />
pOWer line cOnditiOner/upS<br />
Hioki Battery HiTester<br />
HIO,3551bATTERYTEST AU<br />
Takes on-the-spot measurements of the internal resistance, voltage<br />
and temperature of lead-acid batteries, principally for UpS and similar<br />
applications, without needing to shut off the battery. Instantaneous results,<br />
on a three-rank scale of pass, Warning, or Fail, using a composite decision<br />
based on the internal resistance and the voltage. Resolution of 1µΩ,<br />
necessary for high capacity batteries (of at least 500Ah). Includes Hioki<br />
9460 clip type temperature leads.<br />
Model Type Phases VA Output (VAC)<br />
FER,115-2000 Power Transformer<br />
2,000<br />
1<br />
FER,115-1000 1,000<br />
VAR,D-283-Ob Auto Transformer 3 16,000 0~470<br />
VAR,2000<br />
VAR,3000 Variac<br />
3,000<br />
VAR,16000-3<br />
VAR,6500-3<br />
3<br />
20A/ph<br />
8A/ph<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
pOWer tranSfOrmerS<br />
2000<br />
Variac 2kVA 0~260Vac Output<br />
VAR,2000 AU<br />
Variac 3kVA 0~260Vac Output<br />
VAR,3000 AU/MY<br />
Variac 16kVa-3 3ph 20A<br />
VAR,16000-3 AU<br />
Variac 6500-3 3ph 6.5kVA<br />
VAR,6500-3 AU/NZ<br />
Variac 3ph 6.5kVA. 0~470Vac output for 415Vac input, max current 8A/ph.<br />
115<br />
0~260<br />
0~470 ph-ph<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 67
ELEC<strong>TR</strong>ICAL POWER<br />
68<br />
ac SOurceS/inverterS/generatOrS<br />
Model Type VA Output (VAC)<br />
ELG,501<br />
bEH,bL1350C-2<br />
Elgar 501 ac Power Source<br />
ELG,501 AU<br />
AC power amplifier. Operates from 240V 1ph ac. Output ranges on tapped<br />
transformer 0~65, 0~130, 0~260Vac. Output power 500VA. Alternative<br />
oscillators available for 10Hz~10kHz operation. Amplifier output rated over<br />
45Hz~5kHz. Two units may be connected for 1kVA output. Three units may<br />
be used with a single 403 oscillator to give a 3ph output at 1.5kVA.<br />
Behlman BL1350C-2 1350 VA Power Amplifier<br />
bEH,bL1350C-2 AU<br />
AC power amplifier with oscillator. Max power output 1.35kVA. Max current<br />
10A on 0~135V range, 5A on 0~270V range. Output frequency 45~500Hz.<br />
External frequency synchronising input. Remote 0~10Vdc programming<br />
of output frequency and voltage. Digital true rms readout of voltage and<br />
current. Units may be stacked for higher power or 2 & 3 phase operation.<br />
Honda EU3000is Generator 240V/3kVA Inverter Output<br />
HON,EU3000IS AU<br />
3kVA /240Vac generator inverter type. Working on petrol.<br />
Rediline DA3179 12/240V dc-ac Inverter<br />
RED,DA3179 AU/MY<br />
Motor generator. 12Vdc to 240Vac sinewave output. Continuous rating<br />
400W. Intermittent use 600W. Lower duty cycle 50% on, 25% off, 1.2kW,<br />
auto starts on load. Overload protected. Weight 12kg. Overall frequency<br />
regulation 47~53Hz.<br />
AC power Amp 0~270<br />
RED,DA3179 Motor generator 12 V 400 240<br />
PC,250I Sine Wave Inverter 12 V 250 250<br />
pC,300I-24 power Inverter 24 V<br />
pC,300I-12 Power Inverter 12 V<br />
HON,EU3000is Petrol Generator 3000<br />
YAM,EF3000iSE petrol Generator/Inverter Set 3000<br />
<strong>TR</strong>A,230-115 Transformer 1000 115<br />
300<br />
Power Conversions 250I Inverter<br />
pC,250I AU<br />
250W sine wave inverter. 12Vdc input.<br />
Power Inverter 300W 24Vdc Output 240V<br />
pC,300I-24 AU<br />
Sinewave inverter. Output power continuous (peak) 300W (1kW). Frequency<br />
50Hz ±1%.<br />
230 to 115 VAC Transformer 1 kVA<br />
<strong>TR</strong>A,230-115 NZ<br />
Maximum power is 1kW. USA power socket.<br />
Ebbett 1,5kW DC to AC Inverter<br />
Ebb,12/1500 NZ<br />
12Vdc~240Vac 50Hz sinewave inverter. Continuous rating 1,000VA.<br />
Intermittent use 1,500VA. Surge (motor start) 2,000VA. Overload protected<br />
with automatic soft start. Output 230Vac ±5%. Frequency 50Hz ±0.5.<br />
Three pin outlet socket.<br />
Yamaha EF3000iSE 3kVA Petrol Generator/Inverter Set<br />
YAM,EF3KISE AU<br />
Output ac 3kVA 2.8kW @ 240V 50Hz, max harmonic distortion 2.5% (mains<br />
supply can exceed 5%), 12Vdc @ 14A. Sound attenuated enclosure (level<br />
57db(A) @ 7m) with 4 wheels. Dimensions 680w x 445d x 555hmm. Dry<br />
weight 70kg. Engine 4 stroke, air cooled ohv, fuel tank 13L (unleaded),<br />
duration at 25% load 20h with auto throttle on. Electric and pull start.<br />
240
DATA ACQUISITION & RECORDING<br />
70<br />
data lOggerS<br />
Data Loggers<br />
Analogue in<br />
(Ch)<br />
Digital<br />
in<br />
(Ch)<br />
Digital<br />
out<br />
(Ch)<br />
dc<br />
supply<br />
Voltage<br />
Ranges<br />
RTD<br />
Strain<br />
Gauge<br />
TC Comms Memory<br />
Sample<br />
Rate (Hz)<br />
Flashcard<br />
MB<br />
DE,DT605 10<br />
13.65k<br />
5 5<br />
25mV~100V<br />
RS232<br />
1 SRAM 1<br />
DE,DT605-3 (30 unbal)<br />
166.538k<br />
Yes Yes<br />
DE,DT800<br />
12<br />
10baseT/<br />
64M<br />
16 8 10mV~10V<br />
100kHz 64<br />
DE,DT800-4pRO (42 unbal)<br />
RS232 64M<br />
Yes<br />
Yes<br />
HIO,8421-01<br />
16<br />
Yes<br />
8Mb 256<br />
HIO,8421-51<br />
100mV~60V<br />
No LAN<br />
HIO,8422-51 32 No 8Mb 512<br />
YEW,DA100-40CH 40 20mV~50V Yes RS232 0.5<br />
FOU,DAQpRO<br />
FOU,DAQpRO-2<br />
8<br />
0~50mV<br />
0~10V<br />
Yes No<br />
Yes<br />
J,K<br />
USb 512kb 0~10kHz<br />
TIN,TGpR-0804<br />
4~20mA<br />
RS232 15.9k 1s<br />
TIN,TGpR-0704-10VDC 1<br />
0~10V dc<br />
No No<br />
Comms<br />
RS232C<br />
TIN,TGpR-0704-2.5V 0~2.5V RS232C<br />
Memory Recorders for transient<br />
& continued signals<br />
Analogue in<br />
(channels)<br />
Digital in<br />
(channels)<br />
Chart Paper<br />
(mm)<br />
Chart Speed<br />
(mm/s)<br />
FDD Voltage Ranges<br />
Memory<br />
per ch<br />
HIO,8835<br />
100kW<br />
4<br />
100<br />
HIO,8835-01 1Megaword<br />
16<br />
9 Yes 100mV ~400V<br />
HIO,8841 8 200 1M<br />
HIO,8842 16 200 2M<br />
RS232<br />
No<br />
Sample<br />
Rate<br />
No 1MHz<br />
HIO,8860 8 16 200 20 No No Var<br />
YEW,ORM1300 16<br />
YEW,ORM1200<br />
200 100<br />
Yes<br />
100mV ~500V<br />
YEW,ORp1200 8<br />
3k<br />
128k<br />
100kHz<br />
YEW,DL708E 100 Yes 50mV ~800V 1 M Yes 10MHz<br />
Hybrid & Pen Recorders<br />
Analogue in<br />
(Ch)<br />
Chart<br />
Paper<br />
(mm)<br />
Chart Speed<br />
dc<br />
Supply<br />
FDD<br />
Voltage Ranges<br />
(V)<br />
YEW,3057-22 2 150 10mm/s 10mV – 50<br />
YEW,3712-31 3 250<br />
YEW,3712-41 4 250<br />
1,200mm/min 10mV – 200<br />
TC RTD<br />
Sample Rate<br />
(Hz)<br />
YEW,3750 10<br />
150<br />
Yes<br />
YEW,3750-DC 20 Yes Yes<br />
20mV – 50 0.5 Yes<br />
YEW,3760 30 250 1,500mm/h<br />
YEW,DR130 20 150 Yes<br />
135<br />
RS232<br />
Yes
Fourier DAQPRO 8 Channel Data Logger<br />
FOU,DAQpRO AU/NZ<br />
portable, hand held, battery operated 8 channel data logger. 16-bit<br />
resolution, built in graphic LCD, for setting up, graphical display of logged<br />
data. pC communications via USb interface. Signal inputs 0-24mA, 0-<br />
50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range -<br />
25~150OC, pT100 range -200~400OC, T/C ranges J type, -300~1500OC,<br />
K type -250~1100OC, T type -200~400OC. Frequency input one channel<br />
only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000<br />
counts. Memory capacity 512Kb, sampling rates from 1S/Hr to 4,000S/sec.<br />
Supplied with analysis and setting up software.<br />
Fourier DAQPRO8 Batter Operated hand held 8 Channel Data<br />
Logger<br />
FOU,DAQpRO-2 AU<br />
portable, hand held, battery operated 8 channel data logger. 16-bit<br />
resolution, built in graphic LCD, for setting up, graphical display of logged<br />
data. pC communications via USb interface. Signal inputs 0-24mA, 0-<br />
50mV, 0-10V. Temperature input via NTC 10kOHM, 100kOHM, range -<br />
25~150OC, pT100 range -200~400OC, T/C ranges J type, -300~1500OC,<br />
K type -250~1100OC, T type -200~400OC. Frequency input one channel<br />
only, 20~4000Hz, sensitivity 20mV, pulse counter one input 0~65000<br />
counts. Memory capacity 512Kb, sampling rates from 1S/Hr to 4,000S/sec.<br />
Supplied with analysis and setting up software.<br />
DataTaker 1Mb PCMCIA Card for DT Series 2<br />
DE,DT-MEM1024 AU<br />
Memory card for DataTaker DT600 series loggers. Capacity 1.024Mb.<br />
DataTaker DT500/600 Expansion Module<br />
DE,CEM-AD AU<br />
Channel expansion module for DT500 & DT600 data loggers. Adds<br />
10 differential analogue and 20 digital state inputs. Also adds 10 digital<br />
outputs.<br />
DataTaker DT5LTP-R One Channel Logger<br />
DE,DT5LTp-R AU<br />
One channel platinum resistance probe temperature logger. Range<br />
-50~50OC up to 0.1 resolution, -50~250OC up to 0.3 resolution. Memory<br />
store up to 4,048 readings. External probe. Lithium battery.<br />
DataTaker DT800 Data Logger<br />
DE,DT800 AU/NZ<br />
Universal input channels 12 balanced or 42 unbalanced analog channels.<br />
Eight bi-directional digital channels & 8 digital input channels. Solid state<br />
multiplexer protected to ±40V. Max in/out voltage ±12V. Serial sensor<br />
channel can be used with GpS systems. Measures V, 4~20mA, strain, TC,<br />
RTD etc. Sampling rate 200Hz up to 100kHz in burst mode. Instrument has<br />
RS232, RS422, USb, Ethernet (10baseT) & pC card modem communications.<br />
plugable 64Mb memory card stores up to 300,000 (compressed) readings<br />
per Mb. Instrument stores 600,000 (compressed) readings in internal<br />
memory. Total memory capacity 10.2Mb (compressed).<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
data lOggerS<br />
Datataker DT800 Data Logger with Delogger 4Pro & Transit<br />
Case<br />
DE,DT800-4pRO AU<br />
Universal input channels 12 balanced or 42 unbalanced analog channels. Eight<br />
bi-directional digital channels & 8 digital input channels. Solid state multiplexer<br />
protected to ±40V. Max in/out voltage ±12V. Serial sensor channel can be<br />
used with GpS systems. Measures V, 4~20mA, strain, TC, RTD etc. Sampling<br />
rate 200Hz up to 100kHz in burst mode. Instrument has RS232, RS422, USb,<br />
ethernet (10baseT) and pC card modem communications. plugable 64Mb<br />
memory card stores up to 300,000 (compressed) readings per Mb. Instrument<br />
stores 600,000 (compressed) readings in internal memory. Total memory<br />
capacity 10.2Mb (compressed). Supplied with Delogger 4pro & Ip67 pE-800<br />
portable enclosure with mounting frame.<br />
DataTaker DT605 Data Logger<br />
DE,DT605 NZ<br />
Input capacity 100V. LCD display enabling use as a measuring instrument if<br />
preprogrammed for channel parameters. Ten differential or 30 single ended<br />
channels. Channels/sec 25. Digital inputs 4TTL/CMOS. Three counter channels<br />
up to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LED’s. Internal<br />
memory up to 11,000 readings. Optional memory card to 170,000 readings.<br />
RS232C data communications port and RS485 port for networking up to 32<br />
loggers. Maths processing included. Inputs voltage 25mV~2.5Vdc & 100Vdc.<br />
Max sensitivity 2µV. Current 0.25~25mA. Current loop 4~20 mA. Resistance up<br />
to 7kΩ. Thermocouples b, C, D, E, G, J, K, N, R, S and T from -250~1,800OC. Thermistors and RTD’s. Strain gauges. Supplied with Determinal and Delogger<br />
software. Operates from internal battery, external battery or ac mains.<br />
Data Taker DT605-3 Series 3 Data Logger<br />
DE,DT605-3 AU<br />
Input capacity 100V and built in SRAM Card Slot. LCD display enabling<br />
use as a measuring instrument if pre-programmed for channel parameters.<br />
Ten differential or 30 single ended channels. Channels/sec 25. Digital<br />
inputs 4TTL/CMOS. Three counter channels up to 1MHz. Up to 120 alarms<br />
with 1 digital I/O and 3 front panel LED’s. Internal memory up to 166,530<br />
readings. Optional 1Mb memory card to 343,980 readings. RS232C data<br />
communications port and RS485 port for networking up to 32 loggers. Maths<br />
processing included. Inputs V 25mV~2.5Vdc & 100Vdc. Max sensitivity<br />
2µV. Current 0.25~25mA. Current loop 4~20mA. Resistance up to 7kΩ.<br />
Thermocouples b, C, D, E, G, J, K, N, R, S and T from -250~1,800OC.<br />
Thermistors and RTD’s. Strain gauges. Supplied with Determinal and<br />
Delogger software. Operates from internal battery, external battery or ac<br />
mains.<br />
DATA ACQUISITION & RECORDING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 71
DATA ACQUISITION & RECORDING<br />
72<br />
data lOggerS<br />
Hioki 8421-01 16 Channel Data Logger with Colour Display<br />
HIO,8421-01 AU<br />
Sixteen analogue, 4 pulse input channels data logger with colour display,<br />
pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />
real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVdc, 1Vdc,<br />
10Vdc, 60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5~26) R,<br />
S, b, -100~100OC, -200~500OC, -200~2,000OC, RTD pt100 -200~800OC.<br />
Pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts<br />
fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording<br />
interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 &<br />
5min. Max sampling rate is dependent upon type of input signal. Internal<br />
Memory 8Mb, 256Mb Flashcard, 9334 logger communicator software, 9642<br />
LAN cable, 9641 pulse signal input cable all supplied.<br />
Hioki 8421-51 16 Channel Data Logger with Colour Display<br />
HIO,8421-51 AU<br />
Sixteen Analogue, 4 pulse input channels data logger with colour display,<br />
pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />
real time pC logging, FTp, SMTp and HTTp. Signal inputs- 100 mVdc, 1Vdc,<br />
10 Vdc, 60Vdc, 1-5Vdc f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R,<br />
S, b, -100~100OC, -200~500OC, -200~2000OC, RTD pt100 -200~800OC.<br />
Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s,<br />
2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval selectable from<br />
100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max<br />
sampling rate is dependent upon type of input signal. Internal Memory 16MW,<br />
512Mb pCMCIA FLASH card, 9334 Logger Communicator software, 9642<br />
LAN cable, 9641 pulse signal input cable all supplied. Improved common<br />
mode rejection- 100db or better when 50/60Hz, 140db or better when 50Hz,<br />
using ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling<br />
when using Pt100, improved temperature characteristics.<br />
Hioki 8422-51 32 Channel Data Logger Logger<br />
HIO,8422-51 AU<br />
Thirty two analogue, 4 pulse input channels data logger with colour display,<br />
pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />
real time pC logging, FTp, SMTp and HTTp. Signal inputs: 100mV, 1, 10 &<br />
60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, b, -100<br />
~100OC, -200~500OC, -200~2,000OC. pulse input, accumulation 50,000<br />
counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs & 2,500M counts<br />
fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200,<br />
500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent<br />
upon type of input signal. Internal Memory 8Mb, 512Mb pCMCIA FLASH<br />
card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse<br />
signal input cable all supplied.<br />
Yokogawa MV200 Twenty Channel Logger<br />
YEW,MV200 NZ<br />
Twenty channel voltage, RTD and thermocouple logger. Color LCD display<br />
10.4” TFT, removable pCMCIA ATA flash memory card. Supports data<br />
collection over ethernet networks. Supplied with RJ-45 cable and standard<br />
software.<br />
Yokogawa Data Logger for PC Acquisition<br />
YEW,DA100-40CH AU<br />
pC based datalogger with dc supply. Channels 40, 50V max input 0.05%<br />
basic accuracy. Accepts RTD and TC inputs. Must be used in conjunction<br />
with a PC includes analysis software. Scan rate 2s.<br />
Yokogawa 2423A Six Channel Logger<br />
YEW,2423A17 NZ<br />
Portable voltage and thermometer logger. Ranges are 10, 1 & 0.1V. Type<br />
K, E, J, T, R, S, b, L, U thermocouples. Memory stores 14,000 data points.<br />
Min logging interval is 10s. Large LCD display, analogue and RS232 output.<br />
Supplied with software for uploading data to CSV or TxT format.<br />
> NEW Hioki 3632-20 Temperature Logger with Internal<br />
Sensor Only<br />
HIO,3632-20 AU<br />
Temperature logger (1 channel) includes 1 x RS232C & 1 x USb<br />
communication base, utility software, RS232C and USb interface cables.<br />
Temperature range -20~+70ºC. Accuracy -20~-0.1ºC +/-1.0ºC. 0~35ºC +/-<br />
0.5ºC, 35.1~70ºC +/-1.0ºC. Internal thermistor sensor, water resilience Ip67.<br />
Built in LCD.<br />
Hioki 3641-20 Temperature/Humidity Logger with RS-232C &<br />
USB<br />
HIO,3641-20 AU/MY<br />
Includes 1 x RS232C & 1 x USb communication base, utility software,<br />
RS232C & USb interface cables. Temperature range -40~85OC, humidity<br />
range 0%~100%RH. Accuracy temperature -40~-0.1OC ±1, 0~35OC ±0.5,<br />
35.1~70OC ±1 & 70.1~85OC ±2. Humidity typical between ±5~±10%RH<br />
depends on temperature and humidity range.<br />
Hioki 3641-20-Kit of 8 Temperature & Humidity Loggers<br />
HIO,3641-20-KIT AU<br />
Kit of 8 x temperature and humidity loggers. Includes 1 x RS232C and 1<br />
x USb communication base, utility software, RS232C and USb interface<br />
cables. Temperature range -40OC~85OC, humidity range 0.0%RH to 100%<br />
RH. Accuracy: Temperature -40~-0.1OC +/- 1.0OC , 0.0~35OC +/- 0.5OC,<br />
35.1~70OC +/- 1OC, 70.1~85OC +/- 2OC. Humidity typical between +/-5 to<br />
+/-10% depends on temperature and humidity range. 8000 data points x 2<br />
channels, recording interval 2,5,10,15,20,30 sec,1,2,5,10,15 ,20,30,60 min.<br />
Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles<br />
FOU,MICROLOG-KIT AU<br />
Set of 5 temperature and humidity loggers mounted in RF transmitter<br />
cradles, one receiver for PC. Transmission range up to 300m or RS232C<br />
& USb interface also included if direct connection to pC for down loading<br />
required. Temperature range -30~50OC, accuracy ±1O, 0~100%RH<br />
accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points<br />
between 2 channels. User defined sampling rate from 10s~2h. MicroLog<br />
Plus management control software included to control and monitor all the<br />
loggers remotely on PC within transmission range.<br />
Escort Temperature Humidity Logger Set of 10<br />
ESC,HUM/T-KIT AU<br />
ESC,HUM-KIT NZ<br />
Includes software and communication base for down loading of data from<br />
loggers to a PC. Data presented in table or graph form. Max sample rate<br />
1min.
Escort Analogue Adaptor<br />
ESC,ANALOGUE NZ<br />
Analogue adaptor for dc voltage and dc current inputs. Inputs: 0~20mA, 0~2<br />
VDC, 0~10Vdc.<br />
Escort Four Channel Temperature Logger<br />
ESC,4 ExT NZ<br />
Range -20~60OC. Resolution 0.3OC. Accuracy 0.5OC. Stores 30,000<br />
readings. Supplied with software, interface and 3m long temperature<br />
sensors.<br />
Escort Three Channel Low Temperature Logger<br />
ESC,3ExT-LO/SS NZ<br />
Range -40~40ºC, accuracy 0.5ºC, resolution 0.3ºC. Supplied with 3<br />
temperature sensors and software.<br />
Escort Internal Temperature Logger<br />
ESC,INT-LO NZ<br />
Single channel low temperature logger. Range -40~40ºC, resolution is 0.5ºC,<br />
accuracy is 0.3ºC. Can be immersed in liquid. Stores 24,000 readings.<br />
Supplied with software and serial interface for uploading data.<br />
Escort pH Adaptor<br />
ESC,pH-ADApTOR NZ<br />
Glass electrode type pH adaptor probe. Range 0~14pH, resolution 0.015pH.<br />
User calibration via offset and slope adjustment screws. Supplied with 10m<br />
temperature compensation probe. WARNING!! Do not use the electrode in<br />
perchlorate, silver, sulphide or any hydrofluoric solutions containing more<br />
than 1M acid or base, or at temperatures more than 50ºC. Use at high<br />
temperatures may shorten the life of the electrode.<br />
Escort Autoclave Logger<br />
ESC,AUTOCLAVE NZ<br />
Temperature logger suitable for use in autoclave sterilizers. Temperature<br />
range is 25~150ºC, resolution: 0.5ºC, accuracy: ±0.5ºC. Rated to 150ºC<br />
for 30min or 125ºC for indefinite. Maximum of 60min endurance for dry<br />
heat oven @ 150ºC. Stainless steel body with 1 external sensor, stores<br />
2000 readings in its memory. IP68 rated to 5bar. Supplied with calibration<br />
certificate, software and serial interface for programing & uploading.<br />
data lOggerS<br />
Tiny Tag One Channel 0~20mA Current Input Logger<br />
TIN,TGpR-0804 AU<br />
Logger 4~20mA single channel. Readings 15,900. Re-scalable Ip68 78w x<br />
50d x 34hmm. Two level alarm leds. Accuracy 0.6% 0.1mA.<br />
Tiny Tag TGPR~0704~10Vdc Data Logger<br />
TIN,TGpR-0704-10VDC AU<br />
Single channel 0~10Vdc logger , 8 bit A to D resolution. Stores 15,900<br />
readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />
Range: 0~10Vdc, max input 14V, accuracy ±40mV, ±1% rdg, 400kΩ<br />
impedance. Battery operated.<br />
Tiny Tag TGPR~0704~2.5Vdc Data Logger<br />
TIN,TGpR-0704-2.5V AU<br />
Single channel 0~2.5V logger, 8 bit A to D resolution. Stores 15,900<br />
readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />
Range 0~2.5V range, max input 3.5V, accuracy ±10mV. battery operated.<br />
Testo 177-H1 Logger with Display<br />
TES,177-H1 MY<br />
parameters: Humidity/Temp/Dew point. Sensors: Humidity Sensor/<br />
NTC(internal). No of Channels: 4 CH. Measuring Range: 0~100%RH &<br />
-20~+70 celcius(internal). Memory: 48,000 readings.<br />
Testo 177-T4 Logger with Display<br />
TES,177-T4 MY<br />
parameters: Temperature(C/F). Sensors: Thermocouple Type-K. No of<br />
Channels: 4 CH(external). Measuring Range: -100~+1000 celcius(external).<br />
Memory: 48,000 readings<br />
inStrumentatiOn amplifierS<br />
Vishay 2100 Eight Channel Instrument Amplifier<br />
VIS,2100 AU<br />
Eight channel signal conditioner/amplifier system comprising 4 dual amplifiers with power supply, digital output display and rack frame. Accepts low level<br />
signals and conditions and amplifies them to drive recorders. bridge balancing for quarter (120 & 350Ω), half & full bridge (50~1kΩ). Quarter bridge dummy<br />
resistors provided. Gain 100~2100. bandwidth dc ~5kHz at 0.5db, 13kHz at 3db. Output ±10V @ 30mA, 50mA into 150Ω, 100 mA into 15Ω. Type 2130<br />
digital readout can be switched to each output in turn and also to an external source. Ranges ±1,999mV & 19,999mV.<br />
Yokogawa ORP1200 8 Channel Memory Recorders<br />
YEW,ORp1200 AU/MY<br />
In-built waveform display. Input ranges 100mV~500V. Max input voltage<br />
is 500V peak or 350V rms ac. Memory 32k per channel, may be combined<br />
for 2 channel 128k operation. Memory may be divided into 16 blocks of<br />
2k. 128k memory at 1kHz sampling (20 points of 50Hz cycle) gives 128s<br />
storage. Real time recording 10mm/hr~100mm/s. Real time recorder with<br />
memory trigger facility. 4 triggers including high, low, rise, fall, with and/or<br />
facility. x-Y operation with up to 4 channels. Memory card facility for storing<br />
memory dumps and setups. Memory card not included.<br />
Yokogawa ORM1300 16 Analogue Channel Memory Recorders<br />
YEW,ORM1300 AU<br />
Similar to YEW,ORM1200 except it has 16 analog channels rather than 8.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
memOry recOrderS<br />
Yokogawa ORM1200 8 Channel Memory Recorders<br />
YEW,ORM1200 AU<br />
Similar to YEW,ORp1200 except it has 128K RAM per channel (ie. 512K<br />
when used as a 2 channel recorder) includes FDD.<br />
Yokogawa DL708 8 Channel Recorder/Digital Scope<br />
YEW,DL708E MY<br />
Eight channels 10M/s sampling 10 bit 8M word of memory, 1.2Gb HDD<br />
(100k/s sampling continuously to disk). In-built printer, FDD, RS232, GpIb<br />
and VGA. Input ranges 5mV/div~200V/div . 800V isolated input capability<br />
(using x10 probes). Input filters, FFT, color display, measurement of 26<br />
waveform parameters. Simple and advanced trigger including a window<br />
trigger.<br />
DATA ACQUISITION & RECORDING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 73
DATA ACQUISITION & RECORDING<br />
74<br />
memOry recOrderS<br />
> NEW<br />
Hioki 8860 8 Channel High Speed Memory Recorder<br />
HIO,8860 AU<br />
High speed memory recorder, 20MS/s sampling rate, 8 analog channels, 16<br />
logic channels, built in printer. 512MW or direct access memory, 60GB hard<br />
drive built-in, pC card type II slot up to 4Gb ATA flash card (optional) USb,<br />
LAN interface and large colour screen.<br />
> NEW<br />
Hioki 9725 Memory Viewer Software<br />
HIO,9725 AU<br />
Data processing software for Hioki 8860 High Speed Memory Recorder.<br />
Functions: file loading, maximum loadable data size 2GW file saving,<br />
measurement of data binary, partial saving between A/b cursors is possible.<br />
Screen images BMP and PNG, calculation results. Display of saved<br />
binary files, displayable channels per sheet analog 32, logic 16 channels.<br />
Displayable sheets 16.<br />
> NEW<br />
Hioki 8938 FFT Input Signal Module<br />
HIO,8938 AU<br />
FFT Module with anti-aliasing filter. Frequency range dc to 400kHz, sampling<br />
rate 1MS/s. Maximum input voltage 400Vdc, 240Vrms.<br />
Hioki 8810 4 Channel Memory Recorders<br />
HIO,8810 AU<br />
4 functions: memory x-T, continuous x-T, memory x-Y, continuous x-Y. 3<br />
channel x-Y is possible. Input amplifier bandwidth 0~100 kHz limited by<br />
max sampling rate of 4µs in memory mode and 100~200µs in continuous<br />
modes. Memory size per channel 8k with 8 bit resolution. paper 110mm<br />
x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in<br />
memory mode giving 32ms~1,600s display. Continuous mode chart speed<br />
1s/div~50min/div in 12 steps. Input floating 10mV/div~5V/div in 12 steps<br />
with fs offset. Internal trigger with level control. External trigger TTL or<br />
contact closure. Successive transient recording possible. Multiple recorder<br />
synchronization possible.<br />
Hioki 8811 3 Analogue 8 Digital Channel Memory Recorders<br />
HIO,8811 AU/MY<br />
Four functions, memory x-T, continuous x-T, memory x-Y & continuous x-Y.<br />
Three channel x-Y is possible. Input amplifier bandwidth 0~100kHz limited<br />
by max sampling rate of 4µs in memory mode and 100~200µs in continuous<br />
mode. Memory size per channel 8k with 8 bit resolution. paper 110mm<br />
x 30m. Full scale 90mm in 10 divisions. Time axis up to 160 divisions in<br />
memory mode giving 32ms~1,600s display. Continuous mode chart speed<br />
1s~50min/div in 12 steps. Input floating 10mV~5V/div in 12 steps with<br />
full scale offset. Internal trigger with level control. External trigger TTL or<br />
contact closure. Successive transient recording possible. Multiple recorder<br />
synchronization possible. Hioki 9306 and 9307 probes optional.<br />
Hioki 8835 4 Channel Waveform & 16 Channel Memory<br />
Recorder<br />
HIO,8835 AU<br />
Memory 12 bits x 100k per channel or 500k for a single channel. Analog<br />
input channel ranges 10mV~50V/div, 10x div, 400Vdc, 240Vac rms max.<br />
In-built FDD and type-III pC card slot. Fastest sampling rate 1MHz. paper<br />
110mm x 30m. Colour TFT display. Additional functions include waveform<br />
parameter calculation including rms values, area value, rise and fall times.<br />
AC mains operation.<br />
Hioki 8835-01 4 Analogue, 16 Logic Channel Waveform<br />
Recorder<br />
HIO,8835-01 AU<br />
Memory 12 bits x 1 megaword per channel or 4 megaword for a single<br />
channel. Analog input channel ranges 10mV~50V/div, 10x div, 400Vdc,<br />
240Vac rms max. In-built FDD & type-III pC card slot. Fastest sampling<br />
rate 1MHz. paper 110mm x 30m. Colour TFT display. Additional functions<br />
include waveform parameter calculation including rms values, area value,<br />
rise and fall times. AC mains operation. Logic probes must be rented<br />
seperately.<br />
Hioki 8841 8 Analogue, 16 Channel Memory Recorder<br />
HIO,8841 AU/NZ<br />
Memory 12 bits x 4 megawords/ch for 2 analog ch, to 1 megawords/ch for<br />
8ch. In-built FDD, type III pCMCIA card slot (for flashcard & HDD up to<br />
520Mb). Sampling rate of 1MHz max. Functions memory, real time record,<br />
rms, real time/memory, x-Y memory, FFT. Trigger functions level, window<br />
in, window out, voltage drop, rms level, cycle, logic pattern trigger 1,0 or<br />
x (disregard). When using logic channels, logic probes must be rented<br />
seperately. Measurement range 400Vdc, 240V rms, low pass filters 5Hz,<br />
500Hz, 5kHz or 100kHz, input coupling dc, GND, ac. Large 10.4” colour<br />
TFT display for settings and waveform display, wide thermal printer fitted.<br />
On screen help function. All settings and waveforms can be saved to media,<br />
waveforms can be saved as binary, text or bmp files.
Hioki 8842 16 Analogue, 16 Logic Channel Waveform Recorder<br />
HIO,8842 AU<br />
Memory 12 bits x 16 megawords/ch for 2 analogue ch, to 2 megawords/ch<br />
for 16 ch. Analogue input channel ranges 10mV~50V per div, 10x div, 400V<br />
dc, 240V ac rms max. In-built FDD, type III pCMCIA card slot (for flashcard<br />
& HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory, real<br />
time record, rms, real time/memory, x-Y memory. Trigger functions level,<br />
window in, window out, voltage drop, rms level, cycle, logic pattern trigger<br />
1,0 or x (disregard). When using logic channels, logic probes must be rented<br />
seperately. Measurement range 400V dc, 240V rms, low pass filters 5Hz,<br />
500Hz, 5kHz, or 100kHz, input coupling dc, GND, ac. Large 10.4” colour<br />
TFT display for settings and waveform display, wide thermal printer fitted.<br />
On screen help function. All settings and waveforms can be saved to media,<br />
waveforms can be saved as binary, text or bmp files.<br />
Hioki 9335 Wave Process Software<br />
HIO,9935 AU<br />
Waveform Processor software, displays, converts to CSV, calculates and<br />
prints waveforms with a pC. Review stored binary files from Hioki 8835,<br />
8835-01, 8841 and 8842 memory recorders. Only way stored binary files<br />
can be viewed on a PC without having to re save them with memory recorder<br />
as Text files.<br />
Hioki 9305 Trigger Cord for Hioki Memory Recorders<br />
HIO,9305 AU<br />
Plug each end of cable 3.5mm. Trigger cord enables master slaving of the<br />
Hioki 8835, 8810 and 8811 memory recorders. One end connected to the<br />
trigger output socket of master recorder the other end connects to the trigger<br />
input socket of the second recorder which is the slave. Trigger pattern set up<br />
for the master and the slave recorder set just to external trigger.<br />
Hioki 4 Channel Digital Probe for use with HIO,8835<br />
HIO,9306 AU<br />
Contact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory<br />
recorders. Threshold digital >1.4V maximum input 50V. Contact closure<br />
input, 2kΩ input resistance 30V allowable input. Response time 2µs.<br />
Hioki 9320 4 Channel Contact & Digital Logic Probe<br />
HIO,9320 AU<br />
For HIO, 8811, 8835, 8835-01, 8841 & 8842 memory recorders, 4 channels<br />
per probe, max of 4 probes per recorder. Use in conjunction with 9321 line<br />
logic probe. Threshold digital selectable 1.4V, 2.5V & 4V. Response time<br />
500ns max. Relay dry contact detection. Max allowable input 50Vdc.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
memOry recOrderS<br />
Hioki 9321 Line Logic Probe<br />
HIO,9321 AU<br />
Four channels (insulated) per probe. Detection of 60~150Vac, 170~250Vac,<br />
20~150Vdc & 70~250Vdc in 2 ranges. Response time slope rise 1ms, fall<br />
3ms. Max input low range 150V rms, high range 250V rms. Max rated<br />
voltage to earth 250V rms. Connector cable 1.5m. Probe tip cable 1m.<br />
Hioki Kit of Three 9322 High Voltage True rms Interface<br />
HIO,9322-KIT AU<br />
Used with many memory recorders, eg. Hioki 8835. Operating modes 3. DC<br />
mode for waveform monitor output dc to 3MHz, ac mode detection of power<br />
surge noise 1 kHz~10MHz. Rectified true rms output of dc & ac voltages.<br />
40Hz~100kHz response speed 200ms or less. Max voltage dc 2kV, ac 1kV<br />
CATII, ac/dc 600V CATIII, balanced differential input 1/1,000 divider.<br />
Hioki 520Mb PCMCIA Hard Disk for HIO,8835 & 8841<br />
HIO,8835-HD520 AU<br />
Data can be stored as mem file which is binary, data can be replayed on<br />
recorder, txt file which is text so as data can be read using excel, bmp file so<br />
screen dump can be saved for import to word document, single or dual FFT<br />
binary file for playback on recorder. File can be saved as setting file, useful<br />
for customers who rent the memory recorder for same applications again.<br />
Transfer files to a PC and reload next time recorder is rented, saves time<br />
in use of recorders. Card can be plugged in to a pCMCIA Type III slot on a<br />
laptop, files can be stored or viewed.<br />
Hioki 9555 Current Sensor<br />
HIO,9555 AU<br />
For HIO,9278 clamp on CT. Output designed for waveform recording and<br />
depends on CT.<br />
Sandisk Compact Flash Card 512MB with PCMCIA Adaptor<br />
COM,FLASH512Mb AU<br />
Compact Flash Card 512Mb typeI with pCMCIA Adaptor.<br />
Hioki 9278 Universal Clamp-on CT<br />
HIO,9278 AU<br />
For use with HIO,9555. Range 0~200A, dc 100kHz, 20mmØ max jaw.<br />
Hioki 9132 Clip-on ac Current Transducer<br />
HIO,9132 AU/NZ<br />
Ranges 20~1kA fs. Short term overload capability 2kA. Output 0.2Vac. For<br />
use with Hioki 8800 series recorders, for current waveform recording.<br />
Hioki 9018-10 500A ac Clamp-On Transducer<br />
HIO,9018-10 AU<br />
Selectable ranges 10~500A. Output voltage 200mVac fs per range selected.<br />
Up to 3kHz frequency response. bNC connection.<br />
Hioki 3270 Sensor with 150A ac/dc Clamp-On Transducer<br />
HIO,3270-9276 AU<br />
Frequency bandwidth dc to 1MHz, rated output 1.5V for fs of range. Clamp<br />
20mmØ. Suitable to view waveforms with memory recorders.<br />
Hioki 9555 Signal Conditioner with 9278 200A ac/dc Clamp-On<br />
Transducer<br />
HIO,9555-9278 AU<br />
Frequency bandwidth dc to 100kHz, rated output 2V for fs of range. Clamp<br />
20mmØ. Suitable to view waveforms with memory recorders.<br />
Hioki 9304 Input Attenuator for 8800 Series Recorders<br />
HIO,9304 AU/NZ<br />
Max input 600Vdc/ac peak.<br />
DATA ACQUISITION & RECORDING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 75
DATA ACQUISITION & RECORDING<br />
76<br />
Strip chart recOrderS<br />
Yokogawa 3057-22 2 Pen Portable Recorder<br />
YEW,3057-22 AU/NZ<br />
Twelve input ranges 10mV~50V fs, 150mm x 15m Z fold or roll chart, speeds<br />
20mm/h~600mm/min. Accuracy 0.5%. power 240/50Hz, rechargeable<br />
NiCad battery or 12Vdc external.<br />
Yokogawa 3712-31 3 Pen Vertical Chart Recorder<br />
YEW,3712-31 AU<br />
Input ranges dc voltage 10mV~200V fs. Thermocouples including type T<br />
& K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory<br />
card optional.<br />
Yokogawa 3712-41 4 Pen Vertical Chart Recorder<br />
YEW,3712-41 AU<br />
Input ranges: dc voltage 10mV~200V fs. Thermocouples including type T<br />
& K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory<br />
card optional.<br />
Yokogawa 3750 10 Channel Multipoint Recorder<br />
YEW,3750 AU<br />
Ten channel hybrid recorder. Input ranges dc 20mV~20V, thermocouple,<br />
RTD. Scans 10 channels in 2s. AC mains operation.<br />
vOltage current recOrderS<br />
Tech-Rentals CT Terminations for Hioki 8710, etc<br />
<strong>TR</strong>,CT-5 AU<br />
Termination box for 5A output current transformers. For use mainly with<br />
HIO,8710. Comprises quantity 3 shunts 0.04Ω. Output 0.2V @ 5A. Use<br />
with DRA,<strong>TR</strong>2015’s.<br />
Hioki 8206 2 Channel Voltage & Current ac Chart Recorder<br />
HIO,8206 AU<br />
The chart records a true rms. Equivalent reading. AC voltage channel, 3<br />
ranges 50~140V, 100~280V & 250~600V. AC current channel, 0~10, 0~20,<br />
0~50, 0~100, 0~200 & 0~500. Chart speeds 600mm/h~20mm/h. Note the<br />
supplied 9651 clamp-on current probe will measure max 46mmØ conductor.<br />
Frequency range of the clamp 40Hz~1kHz.<br />
tape recOrderS<br />
Teac 16 Channel DAT Instrumentation Recorder<br />
TEA,RD145T AU<br />
Sixteen channel DAT instrumentation/data tape recorder. 4ch~20kHz, 8ch-10kHz, 16ch~5kHz, ac/dc operation. Ch 1 can be selected for analogue or 14-bit<br />
digital. Data recorded at slow speeds can be played back at double speed. Input ranges 0.5, 2, 5 & 20Vp impedance 100kΩ unbalanced output ranges 2~5Vp<br />
variable impedance 75Ω unbalanced. AC or 11~30V dc operation.<br />
plOtter printer<br />
Yokogawa 3750-DC 20 Channel Hybrid Recorder<br />
YEW,3750-DC AU<br />
Input ranges dc 20mV~50V, thermocouple & RTD. Scans 20 channels in 2s.<br />
Operates from 10~32V external dc. RS232C interface option fitted.<br />
Yokogawa 3760 30 Channel Recorder<br />
YEW,3760 AU<br />
Analogue and digital printout. Ten colour with channel identification number.<br />
Scans in 2s. Chart speeds 1~1500mm/h. Inputs dc (20mV~50V range),<br />
thermocouple (R, S, b, K, E, J, T, L, U, N, W, Kp) & RTD. Memory card<br />
reader. Memory card included with several typical set-ups.<br />
Yokogawa DR130 Hybrid 20 Channel Recorder FDD<br />
YEW,DR130 AU<br />
Includes 3.5” FDD. Input unbalanced floating 20mV~50Vdc, TC, RTD and<br />
contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width<br />
150mm. Data can be saved to 500k of internal RAM either directly or due to<br />
alarm conditions. The saved data can be copied to a 3.5” FDD file suitable<br />
for inclusion in standard spreadsheet programmes.<br />
Yokogawa 512K Memory Card for Yokogawa Recorders<br />
YEW,MEM512 AU<br />
Memory card 512k. For YEW,3750, YEW,3760, YEW,3712-31 YEW,3712-<br />
41 and YEW,3701-85 recorders.<br />
Hioki 8710 3 Channel ac/dc Recorder<br />
HIO,8710 AU/NZ<br />
Intended mainly for recording ac line voltage and current. Data is recorded<br />
graphically and printed. Input voltage ranges 70~750V rms ac in 4 ranges<br />
with optimised scale, 0.05~7.5V dc in 5 ranges. AC current ranges using<br />
9008 and 9132 clamp-on probes 10~1000A. Uses type 9221 thermal paper<br />
110mm x 30m. The recorder is suitable for voltage measurements from pAM<br />
thyristor inverters but not all voltage levels with PWM inverters. Chart speed<br />
up to 30 div/min (1div is 9mm). Response time 0.6s.<br />
HP 7440A 8 Pen Plotter<br />
Hp,7440A MY<br />
Media sizes. 210 x 297mm (ISO A4) 8.5 x 11in (ANSI A). Regular plotter paper,glossy presentation paper, fast-dry overhead transparency film. 8 fiber-tip pens,<br />
automatic pen changing & capping. Max plotting area: Y-axis 191mm (7.5in) for A & A4 size paper, x-axis 257mm (10.1in) for A size paper. Resolution:<br />
addressable step size: 0.025mm (0.001 in). pen Velocity: pen up 52 cm/s (20 in/s). pen down max 40 cm/s (16 in/s), programmable 1 to 40 cm/s in 1 cm/s<br />
increments. Acceleration: approx 1.2 g’s. Interface Options: RS-232-C/CCITT V.24 Asynchronous serial, ASCII, 60-byte buffer size.Switch selectable baud<br />
rates: 75~9600. Switch selectable parity: odd, even, or off. HpIb: Switch selectable addresses: 0~31 (31 sets listen-only mode). Size: 308(d) x 460(w) x<br />
125(h)mm. Weight: plotter 4.1kg. power supply 1.4kg.
Model Type<br />
Analog<br />
Out<br />
Druck PTX1400-25 25Bar Pressure Transducer 4-20mA<br />
DRU,pTx1400-25 AU<br />
pressure transducer, 4~20mA output, 0~25 bar (360psi) input. Requires<br />
9~28VDC, supplied with 12V, 500mA power pack.<br />
Druck 580 PSI 40Bar Pressure Transducer 4~20mA<br />
DRU,pTx1400-40 AU<br />
Requires 9~36Vdc, supplied with 12V plug pack.<br />
preSSure & humidity tranSducerS<br />
Pressure<br />
(Bar)<br />
1,000<br />
Differential<br />
Humidity<br />
(%)<br />
ASH,1000<br />
DRU,pTx1400-4 4<br />
DRU,pTx1400-25<br />
DRU,pTx1400-40<br />
4~20mA<br />
25<br />
40<br />
DRU,pTx1400-400<br />
DRU,pTx1400-600<br />
Pressure<br />
400<br />
600<br />
FLU,pV350 42<br />
FLU,pV350-NATA 0~1V 24 Yes<br />
GEM,2200bGb2501A3UA<br />
GEM,2200bGC1001A3UA<br />
4~20mA<br />
25<br />
100<br />
NATA<br />
Operating Temperature<br />
(°C)<br />
KUL,HEM375-5000 High temp pressure 0~100mV 345
PHYSICAL MEASUREMENT<br />
78<br />
diStance meaSurement & Surveying<br />
Digiroll Plus Measuring Wheel & Surveying<br />
DIG,pLUS AU<br />
Measuring wheel. For linear measurement and, area and volume calculation<br />
of construction sites and buildings, etc.<br />
Leica Disto Pro Laser Distance Measurement<br />
LEI,DISTOpRO AU/NZ<br />
Typical accuracy ±1.5mm. Will average over 8 measurements for greater<br />
accuracy. Built in function for height measurement and enclosed angles,etc.<br />
Memory can be divided into groups, e.g. 200 groups with 5 measurements.<br />
Includes PC interface and software, telescope to help find dot in daylight and<br />
bubble level to enable horizontal measurement.<br />
Mitutoyo 500-172 Digimatic Caliper<br />
MIT,500-172 AU<br />
Range 0~200mm (0~8”), resolution 0.01mm (.0005”). Absolute measurement,<br />
LCD display. Temperature operating range 0~40OC, storage temperature -<br />
10~60OC. button settings ON/OFF, inch/mm. Origin, zero/AbS.<br />
Mitutoyo Absolute Digimatic Height Gauge Caliper<br />
MIT,570-314 AU<br />
Digital height gauge for measurement of height of small components/parts.<br />
Functions, origin (absolute origin) setting, AbS (absolute) measurement,<br />
INC (incremental) measurement, hold. Measurement range 24”/600mm,<br />
resolution 0.0005”/0.01mm, error ±0.0020”/0.05mm, display 6 digit LCD.<br />
tachOmeterS/StrObOScOpeS<br />
> NEW<br />
Monarch Palmstrobe Compact Size Portable Stroboscope<br />
MON,pALMS<strong>TR</strong>ObE AU<br />
Compact size portable stroboscope, flash rate from 100~12,500FpM, 6<br />
digit alphanumeric backlit LCD. Tachometer range 5~250,000RpM (only<br />
with external sensor connected, not included). External sensor input TTL<br />
only. Supplied with 2 x removeable rechargeable battery packs, charger<br />
and transit case.<br />
Phantom 53550 Radar Gun kph, with Case and Tuning Fork<br />
pHA,53550 AU<br />
professional doppler K band (24.150GHz) stationary radar gun. Fast action,<br />
pull the trigger and the speed display appears instantly. Unit is invisible to all<br />
radar detectors. power requirements 10.5~16.5Vdc, 13.5Vdc nominal, 1.5A<br />
max, external source, connection via 6’ coiled power cord with fused lighter<br />
plug. Operating environment -20~60ºC, 90%RH @ 37ºC (non-condensing).<br />
Accuracy ±0.17kph. Accuracy verification tuning fork (K-band), internal<br />
90kph. Speed range 17~332kph.<br />
Jenoptik LEM300-GEO Laser Range Finder & Speed Gun<br />
JEN,LEM300-GEO AU<br />
Includes precision inclinometer and compass. Measures up to 300m<br />
horizontal or sloping distances. Distance measurements updated at 50Hz<br />
so accelerations can be analysed via RS232 interface. Overall accuracy<br />
±10cm. Rechargeable batteries.<br />
Hilti PR50 Rotating Laser Level<br />
HIL,pR50 AU<br />
For facade installations, suspended ceilings, excavations, etc. PR50 is a<br />
self leveling rotating laser. System includes tripod and 2 styles of sight, the<br />
first make on audible alarm when the laser is detected, and the second when<br />
detected the system oscillates on to provide good definition of the laser in<br />
high ambient light conditions. Accuracy ±0.7mm in 10m horizontal, ±0.9mm<br />
in 10m vertical. Laser range 30m or more with beam catcher, 150m or more<br />
with laser detector.<br />
Hilti PM10 Multi Directional Laser<br />
HIL,pM10 AU<br />
Triple laser alignment system. Instrument produces 3 visible lasers each at<br />
90O . Supplied with contractors kit including clamps, magnetic bracket, targets<br />
in case. Accuracy ±3mm in 10m, self-leveling from ±4O to horizontal.<br />
> NEW<br />
Monarch PLT200-KIT Digital Contact/Non Contact Tacho<br />
MON,pLT200-KIT AU<br />
Hand held digital contact/non contact tacho kit. Ranges optical/non contact<br />
5~200,000 RpM, contact 0.5~20,000 RpM. Display 5 digits, 5 alpha numeric<br />
LCD. Non contact operating range 90cm, tripod mounting. Direct contact<br />
tips and contact wheel supplied. programmable for IpM, FT/M, YpM, cm/M,<br />
m/M, RpM, RpS, RpH and Totaliser up to 200,000. Output TTL pulse.
Monarch Phaser Strobe Battery Operated<br />
MON,pHASER AU<br />
phaser-stroboscope includes optical and magnetic pickup. Operates from<br />
internal re-chargable batteries or mains. Auto step mode provides slow<br />
motion appearance for high speed repetitive events. Stores and recalls last<br />
3 full settings in memory. Specifications 30~30,000f/min or 0.5~533.33f/<br />
s. Accuracy ±0.01%. Flash rate external triggering 30~9,999.9f/min,<br />
0.5~533.33f/s, 10,000~32,500f/min. phase delay facility.<br />
tachOmeterS/StrObOScOpeS<br />
Hioki 3404 Optical/Contact Tachometer<br />
HIO,3404 AU/NZ<br />
Autoranging 4 digit display. Ranges in RpM mode 30~99.9, 1,000~9,999<br />
& 1,000~9999 x 10. Ranges in RpS mode 0.5~99.99, 100~999.9 &<br />
1,000~1,600. Analogue output 1mV/10RpM or 1mV/100RpM, accuracy 4%.<br />
Tripod mounting. Internal battery or external ac operation. Contact adaptor<br />
included with cone and peripheral ring.<br />
endOScOpeS<br />
Model Type Diameter mm Length - Metre Articulation<br />
FIb,MTFS15-1000<br />
1.5 1 None<br />
MOR,MSGI-1350<br />
MOR,MSpI-3000<br />
MAC,Fb5-1400A<br />
Fibreoptic endoscope<br />
8<br />
4.3<br />
1.3<br />
3<br />
1.25<br />
Semi rigid<br />
2 way<br />
OLY,IF8C5-30 8 3<br />
OLY,IF11D4-20 11<br />
4 way<br />
OLY,IV6C6-20-ZOOM<br />
6<br />
2<br />
OLY,IV6C5-20 51 2 way<br />
OLY,IV8C6-35 Video endoscope<br />
6 3.5 4 way<br />
OLY,IV8D3-20 8.4 2 4 way<br />
OLY,IpLEx-Mx 6 3 4 way<br />
OLY,CYF-3<br />
SIL,PF136<br />
Fibrescope endoscope<br />
6<br />
9<br />
0.37<br />
1.32<br />
2 way<br />
Semi rigid<br />
AQU,SNAKEEYE Colour video flexible cable 30 9.1 None<br />
WHO,VIpER CAMERA KIT Option for Minispring 51 - Rotating head<br />
WOH,MINISPRING Colour video rigid push rod 22 20 None<br />
WOH,VIS220<br />
WOH,VIS2000<br />
RAD,GATORCAM-25-30<br />
RAD,GATORCAM-25-60<br />
Colour video flexible cable<br />
B&W videoscope and recorder<br />
26<br />
51<br />
25<br />
19.5<br />
30<br />
60<br />
None<br />
Rotating head<br />
None<br />
pEA,FLExI-CAM Colour video pipeline inspection system 15<br />
HEI,TECHNO-6x320<br />
6 320mm<br />
OLY,G100-034-090 55 Borescope<br />
10 340mm<br />
SYK,4-30-ARTHRO 4 180mm<br />
DYO,750 Camera and video processor<br />
Pearpoint Flexi-Cam Pipeline Inspection System<br />
pEA,FLExI-CAM AU/NZ<br />
Compact colour video 25mm colour camera with 3lux sensitivity, (light<br />
source white LED’s) on 15m of fully retracting flexi-rod. Flexi-cam navigates<br />
multiple 90O bends in 32mm pipes and images are displayed on the internal<br />
colour TFT screen. Images can be recorded to an external video recorder<br />
(not supplied). System operates from internal fully rechargeable batteries<br />
which provide up to 5h of continuous use when fully charged. Hand-held<br />
portability. Fully waterproof, manually set focus camera. Inspects pipes<br />
25~100mm.<br />
Radiodetection Gatorcam-25-30 Drain Video Inspection System<br />
RAD,GATORCAM-25-30 AU<br />
Monochrome video scope 30m x 25mmØ. Kit includes video display and<br />
VCR combination and 33kHz sonde capability so the camera location can<br />
be determined using the RAD,RD400pxL. Has fixtures to centre the camera<br />
in larger diameter pipes. Camera includes variable illumination. Length of<br />
cable extended is displayed and comments can be added to the image.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Radiodetection Gatorcam-25-60 Drain Video Inspection System<br />
RAD,GATORCAM-25-60 AU<br />
Monochrome video scope 60m x 25mmØ. Kit includes video display and<br />
VCR combination and 33kHz sonde capability so the camera location can<br />
be determined using the RAD,RD400pxL. Has fixtures to center the camera<br />
in larger diameter pipes. Camera includes variable illumination. Length of<br />
cable extended is displayed and comments can be added to the image.<br />
Wohler Minispring 15m x 22mm B&W Inspection Camera<br />
WOH,MINISpRING AU<br />
Semi rigid push rod 20m long with 22mm colour camera. Waterproof to 15m.<br />
Kit includes a small battery operated display with a video output. Large<br />
display and recorder option.<br />
PHYSICAL MEASUREMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 79
PHYSICAL MEASUREMENT<br />
80<br />
endOScOpeS<br />
> NEW Wohler VIS 220 Visual Inspection System for Pipes<br />
and Drains<br />
WOH,VIS220<br />
Compact colour video pipeline inspection system, 26mm colour camera<br />
with bright white LED’s on 19.5m of flexible push rod with metric marking.<br />
Camera sensitivity 3 Lux, lens f=2.5mm, F=2.0, view angle 120º, waterproof<br />
to 30m water depth. Suitable for insertion in pipes and spaces from 40 to<br />
150mm diameter. The system is supplied with 2 battery packs and an AC<br />
charger/power pack, each battery pack lasts approx 1.5h. Supplied with 5.6”<br />
TFT display with extension cable, video output suitable for video recorder<br />
(not supplied).<br />
Wohler VIS2000 30m x 51mm Steerable Color Camera<br />
WOH,VIS2000 AU<br />
For inspection of ventilation ducts, chimneys, chambers and flue gas<br />
systems, etc. Kit consists of color display with joy stick to control the camera.<br />
Flexible 30m cable on a reel, with non-waterproof, splash resistant, 51mmØ<br />
colour camera with illumination. Accessories included to assist for chimney<br />
inspection: a fixture to allow the camera to be lowered down chimneys, a<br />
guide to centre the camera inside chimney-like spaces and a holder to allow<br />
the camera to look up rather than down.<br />
Wohler Viper Camera Kit for Minispring<br />
WOH,VIpER CAMERA KIT AU<br />
Optional camera with remote control movement of camera for<br />
WOH,MINISPRING. Cannot be used on its own.<br />
Aqua Snakeeye 9m x 25mm Video Inspection<br />
AQU,SNAKEEYE AU/MY<br />
For remote inspection work. Very light and compact. Includes a 127mm<br />
TFT-LCD display & 30mmØ camera including illumination. Various adaptors<br />
are supplied for mounting the camera to, your hand, 457mm with 90O<br />
articulation arm or 9.1m extension cable.<br />
Machida FB5-1400A 4.3mmØ x 1.25m Endoscope<br />
MAC,Fb5-1400A AU<br />
End section steerable in 2 axis, 120O. Instrument is fragile due to the narrow<br />
diameter and lack of a thick protective sheath. Light source included.<br />
Moritex MSGI-1350 1.35m x 8mm Semirigid Endoscope<br />
MOR,MSGI-1350 AU<br />
MOR,MSGS-1350 NZ<br />
Size 8mmØ x 1.35m long. Kit includes a 90O side view adaptor, when used<br />
diameter is then 10.1mm. Includes battery light source. View angle 27O.<br />
Focal length 10mm~infinity. Working temperature 0~60OC. Image 13,000<br />
pixel. Optional video camera available.<br />
Olympus CYF-3 6mm Diameter 37cm long Fiberscope<br />
OLY,CYF-3 AU<br />
Fibrescope 6mm diameter, 37cm long fibrescope, articulation 190 deg up<br />
and 90 deg down. Includes CLK-4 light source. Non metal insertion tube,<br />
synthetic rubber.<br />
Moritex PalmScope Video Capture Device for JPEG & Movie<br />
Clip Recorder Inspection<br />
MOR,pALMSCOpE AU<br />
Digital Video Recorder, image capture and storage. Used in conjunction with<br />
an endoscope, borescope or videoscope the PalmScope is an alternative to a<br />
VCR for onsite inspection applications. Unit records, store video sequences<br />
and full frame resolution jpeg images on supplied 512Mb Compact Flash<br />
Card. View images on built in 6.4” TFT LCD screen. Stores jpeg still images<br />
and or mjpeg movie clips. Signal input video NTSC or pAL, auto-selecting.<br />
Moritex 2C Mount Adaptor<br />
MOR,2CMOUNT AU<br />
2C mount adaptor.<br />
Camera Mount for Moritex Eye Piece<br />
MOR,CAM-MOUNT AU<br />
Mount to allow the connection of a standard camera to a Moritex endoscope.<br />
Adaptors connect to where you would normally add a filter to a camera. Ring<br />
sizes which this can adapt to include 52mm, 49mm ,46mm & 37mm. Sony<br />
Mavica (SNY,MAVICA-FD95) can be used, or check the size of the filter<br />
which is used on the camera.<br />
> NEW<br />
Silverado PF136 Portable Fibrescope<br />
SIL,pF136 AU<br />
portable fibrescope, 9mm diameter, 1320mm working length, gooseneck<br />
semi rigid insertion tube, supplied with 90º side view adaptor mirror. built<br />
in battery compartment for LED light source. Viewing direction 0°, viewing<br />
angle 45º, Depth of view 30mm to 150mm. Side view adaptor viewing<br />
direction 90º, viewing angle 45º, depth of view 30mm to 150mm, tip diameter<br />
10mm.
Olympus IPLEX- MX Portable Industrial Videoscope<br />
OLY,IpLEx-Mx AU<br />
IpLEx Mx battery powered industrial videoscope, lightweight just 4.5kg out<br />
of transit case. 6mmØ, 3m length tungsten insertion tube, articulation 4 way<br />
Up/DOWN/LEFT/RIGHT 120O. Field of view 120O, depth of field 18mm<br />
to infinity, illumination method LED. Brightness adjustment 11 step, long<br />
exposure up to 1sec, zoom electronic linear up to 3x, built in 5.6inch TFT<br />
full colour display, image recording built in, image format JPEG, over 230<br />
images with supplied CF card. powered from either rechargable Li-ion 2x<br />
battery packs (4 hours) or AC adaptor.<br />
Olympus Endoscope/Recorder TV Camera Inspection<br />
OLY,VIDEO AU<br />
Video camera, monitor, VCR and adaptor kit to suit Olympus endoscopes.<br />
Two mount adaptor.<br />
Olympus IF8C5-30 8mm x 3m Long Endoscope<br />
OLY,IF8C5-30 AU<br />
Length 3.25m (effective 3m), 8mmØ, angulation range, 4 direction, up/down<br />
120O, right/left 100O, light guide cable length 2m. Optical adaptor fitted<br />
AT60DFF, field of view 60O, forward viewing, depth of field 20mm~infinity.<br />
Outer diameter 8.4mm. Operating temperature in air -10~80OC, in water<br />
10~30OC. Operating pressure water 1,013~1,317hpa (1~1.3atm), air<br />
1,013hpa (1-1.3atm). Fluid resistance insertion tube withstands machine<br />
oil, light oil. Only insertion tube can be placed in water. Supplied with eye<br />
piece and light source.<br />
Olympus IF11D4-20 11.3mm x 2m Length Endoscope<br />
OLY,IF11D4-20 AU<br />
Working length 1.7m. Large sharp images with adjustable focus regardless<br />
of distance. Depth of field of view 8mm~infinity, field of view 78O, direction<br />
of view forward. Easy up/ down 120O, right/left 100O angulation of bending<br />
section which can be locked at any angle. Includes Olympus ILK-5 light<br />
source, halogen lamp. Operating temperature insertion tube including<br />
optical adaptor, in air -10~80OC, in water 10~30OC.<br />
Olympus IV6C6-20-ZOOM Videoscope 6mm x 2m Long<br />
OLY,IV6C6-20-ZOOM AU<br />
Fitted with AT120D/NF optical adaptor, field of view 120O, direction of view<br />
forward, depth of field 5mm~infinity. Angulation 4 way, 150O up/down &<br />
left/right, heavy duty tungsten insertion braid tube. Operating temperature<br />
for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance for<br />
insertion tube - withstand machine oil, light oil and 5% salt water. Supplied<br />
with IV-6A video control unit, which has zooming and virtual scrolling<br />
(panning) with moving images function, extended exposure time for darker<br />
areas, built in image enhancement and freeze frame. ILH-2b light source,<br />
panasonic 7” LCD colour monitor mounted on extension arm all fitted to<br />
transit case for ease of use. Video VHS recorder also included in package.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
endOScOpeS<br />
Olympus IV8D3-20 8.4mmØ, 2m Long Videoscope<br />
OLY,IV8D3-20 AU<br />
Industrial flexible videoscope, 2m long, 8.4mmØ, distal tip non removeable,<br />
field of view 100O, depth of field 7-122mm (fixed focal point). Angulation 4<br />
way, 120O Up/DOWN, 100O RIGHT /LEFT. Heavy duty tungsten insertion<br />
braid tube. Operating temperature for insertion tube in air 0~50OC, in water<br />
10~30 OC. Liquid resistance for insertion tube - withstand machine oil, light<br />
oil and 5% salt water. Supplied with IV-5 video processor unit, ILK-5 light<br />
source and TV/Video VHS recorder.<br />
Olympus IV8C6-35 Videoscope 8.4mm x 3.5m Long<br />
OLY,IV8C6-35 AU<br />
Fitted with AT80D/FF optical adaptor, field of view 80O , direction of view<br />
forward, depth of field 40mm to infinity. Angulation 4 way, 150O in up/down<br />
& left/right, heavy duty tungsten insertion braid tube. Operating temperature<br />
for insertion tube in air -10~80OC, in water 10~30OC. Liquid resistance<br />
for insertion tube - withstand machine oil, light oil and 5% salt water.<br />
Supplied with IV-6 video control unit, ILH-2A light source and TV/Video VHS<br />
recorder.<br />
Dyonics Model 750 Video Camera & Processor<br />
DYO,750 AU<br />
For endoscopes and borescopes with british standard eye piece. TV/Video<br />
recorder not included.<br />
Heine Techno 6mm x 320mm T.05.26.302 Borescope<br />
HEI,TECHNO-6x320 AU<br />
Direction of view 70O , with angled extension tube 120O x 120O . battery pack<br />
included, dc supply cord, battery charger and mains power pack.<br />
Olympus G100-034 090 55 Borescope<br />
OLY,G100-034-090 55 AU<br />
G series rigid borescope 340 mm, 10 mmØ, direction of view 90O, field of<br />
view 55O. Stainless steel insertion tube, operating temperature -20~150OC.<br />
Includes Olympus ILK-5 cold light source, Sony CCD-IRIS colour video<br />
camera, AK2-10C adaptor for Sony CCD-IRIS. View via eye piece or via<br />
video connection to TV.<br />
Stryker Borescope 4 mmx 180 mm Long, 27.5O View<br />
SYK,4-30-ARTHRO AU<br />
Supplied with Quantum 4,000 light source, 597 camera head and video<br />
processing unit. Very high quality system.<br />
Fibrescope MTFS15-1000 1.5mm x 1m Endoscope<br />
FIb,MTFS15-1000 AU<br />
Working length 1.5mmØ x 1,000mm. Includes light source. Operating<br />
temperature -20~60OC at atmospheric pressure.<br />
PHYSICAL MEASUREMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 81
PHYSICAL MEASUREMENT<br />
82<br />
micrOScOpeS<br />
Olympus CH2 Binocular Microscope<br />
OLY,CH2 AU<br />
Magnification of eyepiece x 10. Magnification of objective lens x4, x10, x40,<br />
x100 (oil type) to give a max magnification of 1,000. In-built light source.<br />
Proscope SCA-12770 Video Microscope Kit<br />
pRO,SCA-12770 AU<br />
Hand-held USb video microscope complete kit. Includes 200x, 100x, 50x,<br />
1~10x interchangeable lenses, C Mount adaptor, stand and carry case.<br />
Connects to a pC via USb interface. Software allows snap shot still images<br />
and real time movie files to be saved. Resolution is 640 x 480 pixels.<br />
high Speed videO<br />
Redlake Motionmeter High Speed Digital Camera<br />
RED,MOTIONMETER AU/NZ<br />
Up to 1,000frames/s, selectable 50, 60, 125, 250, 500 & 1,000frame/s,<br />
exposure rates 1x, 2x, 3x, 4x, 5x, 10x & 20x the recording rate. Manual<br />
record, trigger record, adjustable pre trigger 0~100%. Storage 4,098 frames.<br />
playback rates 1,2,3,4,5,10,15,25,30,50, 60,125,250,500 & 1000frame/s.<br />
Output composite video NTSC or pAL (monochrome) also supplied with<br />
video to USb converter, flood lights and tripod.<br />
preSSure vacuum gaugeS/recOrderS<br />
Chroma 7310 Video Microscope<br />
CHR,7310 AU<br />
High resolution colour camera x40 & x200 magnification. Includes<br />
illumination, auto gain control, auto white balance adjustment, etc. Freeze<br />
picture and compare function.<br />
Scalar VL-7EX Video Microscope<br />
SCA,VL-7Ex NZ<br />
Handheld video microscope. View and capture images to a pC or TV/video<br />
recorder. Supplied with a x30 lens, video to USb adaptor and windows<br />
software. Optional 14” TV/video is available.<br />
Polaroid Microcam Microscope Camera<br />
pOL,MICROCAM AU<br />
Instant film camera for binocular microscopes. Simple over eyepiece fitting<br />
permits use with virtually any model.<br />
Redlake Motionscope SR500 High Speed Video<br />
RED,SR500 AU<br />
Triggering facilities similar to a digital oscilloscope. 2,048 frames can be<br />
captured up to 500frames/s. Shutter speeds 1/60~1/5,000s. Images can be<br />
viewed from a frame by frame basis to real time. Monochrome image. pAL<br />
video output. TTL trigger input. Use any standard oscilloscope to supply the<br />
signal. C mount interface on camera. System with C mount adaptor can be<br />
used with endoscope.<br />
Redlake 1000 Frames/Sec Motion Scope<br />
RED,S1000 AU<br />
Triggering facilities similar to a digital oscilloscope. 4,096 frames can be<br />
captured at up to 1,000frames/sec. Images can be viewed from a frame<br />
by frame basis to real time. Shutter speeds 1/60~1/10,000s. Monochrome<br />
image 336 x 243 x 8-bit pixels. Weight 5.5kg. pAL video output. Trigger<br />
input TTL. Use any standard oscilloscope to supply the signal. Adaptor can<br />
be used with endoscope.<br />
Orion VPDC ac/dc Powered Video Recorder<br />
ORI,VpDC AU<br />
pAL b/G portable video recorder includes NTSC playback on pAL TV. Two<br />
rotary heads, helical scanning system, 1 track audio.<br />
Orion 10VRKT 23cm TV with built in VCR<br />
ORI,10VRKT AU<br />
AC/dc combination 10” (23cm) colour TV and video recorder. TV channels<br />
VHF, UHF, audio output power 1.2W max. VCR pAL b/G, 2 head. power<br />
240Vac, 12Vdc. Supplied with remote control.<br />
Model Type Pressure (Bar) NATA Accuracy<br />
bRI,1000-NATA<br />
69<br />
bRI,10000-NATA Pressure recorder<br />
690<br />
Yes 0.5%<br />
bRI,5000-NATA 345<br />
HOB,PRES Pressure logger 1.013 1% fs<br />
STE,1000-NATA<br />
69<br />
STE,10000-NATA<br />
STE,5000-NATA<br />
Pressure gauge<br />
690<br />
345<br />
Yes 0.5%<br />
<strong>TR</strong>,pRESS-NATA 100<br />
CEC,140bAR<br />
CEC,30bAR<br />
Digital gauge & logger<br />
140<br />
30<br />
No ±0.1%
Tech-Rentals 4,000, 6,000 & 10,000kPa Pressure Gauges NATA<br />
Calibrated<br />
<strong>TR</strong>,pRESS-NATA AU<br />
Three gauges. Accuracy ±0.5% 4,000kpa, 6,000kpa & 10,000kpa.<br />
Bristol Babcock 1,000psi Mech Chart Recorder<br />
bRI,1000-NATA AU<br />
Circular pressure chart recorder 1,000psi. 12”Ø. Accuracy ±0.5% NATA<br />
calibrated. Fitted with 2 speed spring wound chart drive giving 7d or 24h<br />
recording. pressure connection ¼”NpT.<br />
Bristol Babcock 5,000PSI Mech Chart Recorder<br />
bRI,5000-NATA AU<br />
Circular pressure chart recorder 5,000psi. Description as above<br />
Bristol Babcock 10,000 PSI Mech Chart Recorder<br />
bRI,10000-NATA AU<br />
Circular pressure chart recorder 10,000psi. Description as above.<br />
Stewart Buchanan 12 1,000 PSI Gauge NATA<br />
STE,1000-NATA AU<br />
Stainless steel, accuracy ±0.5% NATA calibrated. pressure connection<br />
¼”NpT.<br />
Endress & Hauser 4Bar Transducer<br />
E&H,pMp-4bAR NZ<br />
Description as per E&H,pMp-1bar<br />
Endress & Hauser 40Bar Transducer<br />
E&H,pMp-40bAR NZ<br />
Description as per E&H,pMp-1bAR<br />
Endress & Hauser 100Bar Transducer<br />
E&H,pMp-100bAR NZ<br />
Description as per E&H,pMp-1bAR<br />
Jumo 1030 10Bar Pressure Transducer<br />
JUM,1030-0-10bAR NZ<br />
Output 4~20mA. Accuracy is 0.5%. Temperature range -40~85ºC, response<br />
time 30ms.<br />
Jumo 40Bar Pressure Transducer<br />
JUM,40bAR NZ<br />
Output 4~20mA. Accuracy 0.5%. Temperature range -40~85ºC, response<br />
time 30ms.<br />
Schaevitz P3061-4D 4PSI Differential Pressure Transducer<br />
SHA,p3061-4D AU<br />
100” water gauge, 4psi. LVDT type with built-in amplifier. Output 0~5Vdc.<br />
Operates from 10~32Vdc or ac mains.<br />
Kulite 5,000PSI High Pressure Temperature Transducer 260OC<br />
KUL,HEM375-5000 AU<br />
Includes 10V regulated supply. Output 0.020mV/psi.<br />
Trafag 8891 4Bar/58PSI, 0~10V, Pressure Transducer<br />
<strong>TR</strong>A,8891-4-10V AU<br />
Accuracy ±0.3% FS. Overpressure 10bar (145psi). Output 0~10V. pressure<br />
connection G ¼” male. bandwidth 1kHz. Media temperature 125OC. IP65<br />
rated. power supply 15~30V.<br />
Trafag 8891 4Bar, 58 PSI, 4~20 mA, Pressure Transducer<br />
<strong>TR</strong>A,8891-4-20A AU<br />
Accuracy ±0.3% FS. Overpressure 10bar (145psi). Output 4~20mA.<br />
pressure connection G ¼” male. bandwidth 1kHz. Media temperature<br />
125OC. Ip65 rated. power supply 10~30V.<br />
Trafag 8204 1Bar ,14PSI, 4~20mA, Differential Pressure<br />
Transducer<br />
<strong>TR</strong>A,8204-1D-20A AU<br />
Same specification as above.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
preSSure vacuum gaugeS/recOrderS<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Stewart Buchanan 12 5,000 PSI Gauge NATA<br />
STE,5000-NATA AU<br />
Stainless steel, accuracy ±0.5% NATA calibrated. pressure connection<br />
¼”NpT.<br />
Stewart Buchanan 12 10,000 PSI Gauge NATA<br />
STE,10000-NATA AU<br />
Stainless steel, accuracy ±0.5% NATA calibrated. pressure connection<br />
¼”NpT.<br />
XP2i Digital Gauge & Logger 140Bar<br />
CEC,140bAR NZ<br />
Intrinsically safe high accuracy temperature compensated pressure data<br />
logger with IANZ calibration certificate. Records up to 3,000 pressure<br />
measurements. Recording intervals or 1s~8h. Data download and analysis<br />
on any Windows equipped laptop or PC. Data can be saved directly into MS<br />
Excel. Internal battery powers unit up to 3m. Can be used as a reference<br />
gauge with or without a hand pump.<br />
XP2i Digital Gauge & Logger 30Bar<br />
CEC,30bAR NZ<br />
Description as above.<br />
preSSure & humidity tranSducerS<br />
Vega Bar 20 0~1Bar Transducer with Display<br />
VEG,bAR20-1 AU<br />
Output 4~20mA. LCD display and is rated Ip65. Over pressure resistant<br />
to 10bar & -1bar. Measurement accuracy 0.5%, linearity deviation 0.085%.<br />
May be set to bar, psi, kpa, mpa, mmH O, mH O & mbar. Output can be<br />
2 2<br />
4~20mA or 20~4mA. Integration time 0~10s. Density factor may be entered<br />
for mm & m, output simulation indication module has 20 segment bar graph<br />
and 4 digit display which may be scaled (has factory default reset). Supply<br />
required 12~36Vdc.<br />
Schaevitz P53363 500 PSI, 0~5V Pressure Transducer incl<br />
Snubber<br />
SHA,p53363-500 AU<br />
Output 0~5V.<br />
Schaevitz P1241 500PSI Pressure Transducer<br />
SHA,p1241-500 AU<br />
Output 0~5 V. port ¼”bSp (f). Operation12Vdc or mains.<br />
Fluke PV350 Vacuum/Pressure Indicator<br />
FLU,pV350 AU<br />
Can be used with a digital multimeter (eg Metrix Mx45) to act as an indicator.<br />
Range, pressure to 600psi (4137kpa) & vacuum 0~29.22”Hg (0~76cmHg ).<br />
Results in either psi or kpa. Connector ½”NpT (m). Cable 2.4m provided.<br />
Battery powered.<br />
Fluke PV350 Vacuum/Pressure Indicator, NATA Certificate<br />
FLU,pV350-NATA AU<br />
Specification as above but with NATA certificate.<br />
Schaevitz P1241 10,000PSI 0~5V Pressure Transducer incl<br />
Snubber<br />
SHA,p1241-10000 AU<br />
pressure transducer 10,000psi, includes snubber, 0~5V output.<br />
Ashcroft 1,000 Bar Pressure Transducer<br />
ASH,1000 AU<br />
Range 10~36Vdc supply. Output 4~20mA. Connection ¼”NpT (M).<br />
GEM,2200BGC001A3UA 100Bar Pressure Transducer<br />
GEM,2200bGC1001A3UA AU<br />
Can be used with a digital multimeter (eg Metrix Mx45) to act as an<br />
indicator. Transducer could be used with a chart recorder or data logger that<br />
can accept 4~20mA signal input. pressure range is 100bar (10,000Kpa or<br />
1,450psi). Transducer has a 4~20mA output. power supply and connection<br />
leads are supplied.<br />
PHYSICAL MEASUREMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 83
PHYSICAL MEASUREMENT<br />
84<br />
preSSure & humidity tranSducerS<br />
Rotronic Temperature/Humidity Transducer for DataTaker<br />
DT600/605<br />
ROT,HTO45R001V AU<br />
Humidity range 25~90%RH 10mV/%RH accuracy 3% resolution 0.6%.<br />
Temperature range 5~50OC, 10mV/1OC accuracy 1O, rep 0.2OC. Datataker<br />
will supply around 100mA through switched supply. Response time 10s<br />
humidity, 20s temperature. Duct mount model 120mm long x 25mmØ.<br />
Supply 4.8~24Vdc draws 4mA.<br />
pOSitiOn tranSducerS<br />
Houston 1850-40 Position Transducers<br />
HOU,1850-40 AU/NZ<br />
Linearity 0.1% travel 40” (1m). Cable tension 280g. Max velocity 132cm/s.<br />
Output is a variable resistance arranged to provide both high level (V) and<br />
low level (mV) outputs when powered from an external source.<br />
inclinOmeterS<br />
Vaisala HMP 235Y 180OC Humidity Probe<br />
VAI,HMp-235Y AU<br />
High temperature humidity and temperature transmitter. Sensor head<br />
operates from 0~180 O C. Measurement range 0~100%RH. Accuracy of<br />
1%RH at 20 O C. Output 0~5Vdc. Other outputs easily set including 4~20mA.<br />
Operates from 15~30Vdc or ac mains.<br />
Vaisala HMP 135Y 160OC Humidity Probe<br />
VAI,HMp-135Y AU<br />
Same specification as above but sensor head operates from 0~160OC.<br />
Unimeasure P510-40 Position Transducer<br />
UNI,p510-40 AU<br />
Travel 40” (1m). Output 0~5V or 0~10V selectable. Requires 12~30Vdc<br />
source.<br />
Wyler Clinitronic 45 Inclinometer RS-232C<br />
WYL,CL45 AU/MY<br />
Resolution 0.01O. Accuracy better than 30arc sec. Display inclination in all common measurements. Includes RS232 interface for remote display of<br />
inclination and also logging. Settling time
lOad cellS<br />
Model Type Range (kg) Output (V)<br />
bAR,MTC-150<br />
bAR,STC-500 230<br />
bAR,STC-500NATA 230g<br />
bAR,STC-4400 Load cell<br />
2,000<br />
68 0~5<br />
AIC,SG-AST-500 500 0~10<br />
bAR,STC-5000 2,270<br />
bAR,STC-10000 4,536<br />
bAR,STC-20000 9,072<br />
bAR,STC-25000 12,000<br />
EMC,100KG<br />
EMC,200KG Tension load cell<br />
200 Yes<br />
EMC,1000KG 1000 Yes<br />
S<strong>TR</strong>,1590C Compression load cell 8,000<br />
DIL,ED2000R<br />
20,000<br />
Crane scale<br />
DIL,Ex2000 – 5K 5,000<br />
AND,WEIGH-bEAMS Platform Scale 2,000<br />
AND Mercury Platform Weighbeams for Pallet up to 2,000kg<br />
AND,WEIGH-bEAMS AU<br />
Total weight capacity 2,000kg for the 2 weigh beams. Two stainless steel<br />
weigh beams supplied, length 1200l x 100w x 80hmm, weight 13kg each.<br />
Connection cable length 5m. AD4406 display supplied, RS232 output.<br />
Transit case with handles and wheels for ease of handling.<br />
Barlo MTC-150 150lb/68kg Load Cell<br />
bAR,MTC-150 AU<br />
Range 68kg compression and tension. Complete with interface operating<br />
from 12Vdc or ac mains giving 0~5Vdc output.<br />
AIC SG-AST-500 500kg S Type Load Cell with Panel Display<br />
AIC,SG-AST-500 AU<br />
Tension and compression 500kg. Nominal output 2mV/V, max excitation<br />
15Vdc, Ip67 protection, safe load 125%, compensated temperature range<br />
-10~40OC. Thread M12 x 1.75p. Supplied with 2 x detachable rod end<br />
bearings, pM4 -SG-dc-5E load cell panel meter, power 12~48V dc, ac<br />
adaptor supplied, output 0~10V. panel indication in kg.<br />
Barlo STC-500 500lb/230kg Load Cell<br />
bAR,STC-500 AU<br />
Complete with conditioning electronics. Output 0~2V. Uses ½”UNF thread.<br />
Barlo STC-500 500lb/230kg Load Cell NATA Calibrated<br />
bAR,STC-500NATA AU<br />
Specification as above but with NATA calibration. This load cell is suitable<br />
for tension only.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
100<br />
0~2<br />
0~5<br />
RS232/485<br />
Barlo STC-4000 4,400lb/2,000kg Load Cell<br />
bAR,STC-4400 AU<br />
Range 2,000kg compression and tension. Complete with series interface<br />
operating from 12Vdc or ac mains. Output 0~5Vdc. Cable to digital display<br />
unit 6m. Uses ¾”UNF thread.<br />
Barlo STC-5000 5,000lb/2,270 kg Load Cell<br />
bAR,STC-5000 AU<br />
Range 2,270kg compression and tension. Interface operates from 12Vdc or<br />
ac mains. Output 0~5Vdc. Display resolution 1kg.<br />
Barlo STC-10000 10,000lbs/5,000kg Load Cell<br />
bAR,STC-10000 AU<br />
Range 4,536kg compression and tension. Interface operates from 12Vdc or<br />
ac mains. Output 0~5Vdc.<br />
Barlo STC-20000 20,000lb/10,000kg Load Cell<br />
bAR,STC-20000 AU<br />
Range 9,072kg compression and tension. Interface operates from 12Vdc or<br />
ac mains. Output 0~5Vdc.<br />
Barlo 25,000 lb/12,000 kg Load Cell and Display<br />
bAR,STC-25000 AU<br />
Complete with 10m cable. Includes D shackles, analog and RS232 output.<br />
12,000kg load capacity.<br />
PHYSICAL MEASUREMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 85
PHYSICAL MEASUREMENT<br />
86<br />
lOad cellS<br />
EMC 100kg Tension Load Cell<br />
EMC,100KG NZ<br />
100kg S type tension load cell with digital indicator. Accuracy ±0.3% of<br />
reading. Operating temperature range -18~65ºC. Safe overload is 150% of<br />
rated capacity. Supplied with threaded eye hooks. Analogue output.<br />
EMC 200kg Tension Load Cell<br />
EMC,200KG NZ<br />
200kg S type tension load cell with digital indicator. Specification as per<br />
EMC,100kg<br />
EMC 1000kg Tension Load Cell<br />
EMC,1000KG NZ<br />
1,000kg S type tension load cell with digital indicator. Specification as per<br />
EMC,100kg<br />
EMC Load Cell Conditioner<br />
EMC.L/CELL-COND NZ<br />
Load cell conditioning unit with a recorder output. AC mains powered.<br />
Strainstall 8,000kg Compression Load Cell<br />
S<strong>TR</strong>,1590C NZ<br />
8,000 kg compression pedestal load cell.<br />
Dillon ED2000 Crane Scale 20,000kg with Radio Remote<br />
Control<br />
DIL,ED2000R AU<br />
Complete with shackles and radio remote control unit. Range 20,000kg.<br />
Accuracy 0.1%, i.e. 20kg uncertainty. Units of measure kg, kt, mt, & lb.<br />
Resolution 5kg. proof load 200% of rated load. Displays gross and net force.<br />
RS232 and RS485 data outputs. Continuous measurement and peak hold.<br />
materialS teSting<br />
> NEW<br />
Anton Paar DMA 35N Portable Density Meter<br />
pAA,DMA35N<br />
Portable density, specific gravity & concentration meter. Measuring range<br />
0.000~1.999g/cc and 0.0~40.0ºC. built-in pipette style pump for sample<br />
aspiration, with port for optional syringe-filling. Display of specific gravity,<br />
ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically<br />
safe [ATEx] for use with batteries, petrochemicals and solvents. Data<br />
storage of up to 1024 results, with recall, and infrared port for RS232<br />
download to serial printer or PC. Wetted parts glass and PTFE. Battery<br />
powered.<br />
Dillion ED2000 5,000 kg Crane Scale<br />
DIL,ED2000-5K AU<br />
Complete with shackles. Range 5,000kg. Accuracy 0.1%. Resolution 1kg.<br />
i.e. 20kg uncertainty. Units of measure: kg, kt, mt, & lb. proof load 200%<br />
of rated load. Displays gross and net force. Continuous measurement and<br />
peak hold.<br />
UWE 5,000kg Digital Crane Scale<br />
UWE,CS-5T NZ<br />
battery powered digital crane scale complete with hook & shackle. Load<br />
capacity 40kg~5,000kg, resolution 2, accuracy is ±10kg. built in large LED<br />
display, wireless remote control, and charger.<br />
Hydramotion Viscolite 700 Portable Viscometer<br />
HYL,V700S-21 AU<br />
Advanced portable viscometer with stainless-steel probe. Operating range<br />
0.1~10,000mpaps (cp) with integral temperature correction -40~150ºC.<br />
probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm<br />
(viscosity/temperature). Acetal polymer probe base for handheld or clamped<br />
operation, with coiled-cable connection to meter unit with 5 digit display.<br />
Battery powered.
Model Type RS232 Range (g) Resolution (g)<br />
AND,GR-202 Analytical balance Yes 210 or 42 0.1mg or 0.01mg<br />
AND,FC-10K<br />
10kg 0.02<br />
AND,HF-300G Yes 310 0.001<br />
AND,Hp-40KA 20kg 0.5<br />
Counting scale<br />
MET,PB8000I 8.1kg 100mg<br />
ISH,CCS3025 25kg 5mg<br />
OHA,Exp4100<br />
4,100 0.01<br />
AND,AD4714<br />
70 0.01<br />
Moisture balance<br />
Yes<br />
AND,Mx50 51 0.001<br />
AND,FG-150Kb Platform scale 150kg 0.05<br />
AND,HL400 Scale 400 0.1<br />
AND,FS-15KA<br />
15kg 1<br />
Weighing Scales<br />
MET,15KG 15kg<br />
MET,60KG 60kg<br />
AND,WEIGHbEAMS Platform Scale Yes 2000 0.05<br />
A&D Mercury Platform Weighbeams for Pallet up to 2000kg<br />
AND,WEIGH-bEAMS AU<br />
For pallet weighing. Total weight capacity 2000kg for the two weigh beams.<br />
Two stainless steel weigh beams supplied, length 1200mm, width 100mm,<br />
height approximate 80mm, weight of each beam 13kg. Connection cable<br />
length 5 metres. AD4406 display supplied, RS232 output. Transit case with<br />
handles and wheels for ease of handling.<br />
A&D Mercury AD4714 Moisture Balance Scales<br />
AND,AD4714 AU<br />
Moisture content to 0.1%. Sample weight 5~70g. Includes timer and RS232<br />
interface. Weight readability 0.01g. Max temperature 200ºC, heater 185W<br />
infrared.<br />
Ohaus EXP4100 4100g Balance and Counting Scale<br />
OHA,Exp4100 AU<br />
Capacity 4.1kg. Display resolution 0.01g. Multi-unit display. Repeatability<br />
0.005g. RS232 interface.<br />
A&D Mercury FS-15kg Weighing Scales<br />
AND,FS-15KA AU<br />
High resolution 15kg scales. Display resolution 1g. AC & NiCad battery<br />
operation.<br />
A&D Mercury FC-10K Counting Scales<br />
AND,FC-10K AU<br />
High resolution 10kg scales with sample counting facility. Display resolution<br />
1g, internal resolution 0.02g. Sample size user selectable – normally 10<br />
pieces. Max count size up to 999,999. AC & NiCd battery operation.<br />
A&D HP-40KA 40kg Counting Scale<br />
AND,Hp-40KA AU<br />
Capacity 40kg with 0.5g resolution. Can be used to determine battery weight<br />
change with charge, etc.<br />
A&D Mercury FG-150KB 150kg Scales<br />
AND,FG-150Kb AU<br />
Capacity 150kg, 0.05 resolution. Includes RS232 port. National Standards<br />
Commission approved (NSC).<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
ScaleS & balanceS<br />
A&D HF-300G Mercury 300g Counting Scales<br />
AND,HF-300G AU<br />
Scales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port.<br />
Includes counting software. Can be used as counting scales.<br />
Ishida 25kg Digital Counting Scales<br />
ISH,CCS3025 NZ<br />
Maximum capacity 25kg, resolution 5g. Features: unit weight, sample<br />
weight and tare.<br />
A&D Mercury MX50 Moisture Analyser<br />
AND,Mx50 AU<br />
Maximum sample weight capacity 51g, resolution 0.001g, moisture content<br />
accuracy over 1g, 0.1%, over 5g, 0.02%. ,Halogen lamp heater, 400W<br />
max. Drying temperature 50~200OC. Measurement programs 20 sets,<br />
measurement mode moisture content, wet or dry, dry content, ratio, weight.<br />
Heating mode standard, automatic, quick, timer, manual. Display large VFD,<br />
interface RS232C, CD-ROM software supplied. pan sample size diameter<br />
85mm.<br />
Mettler PB8001 8kg Counting Scales<br />
MET,pb8001 AU<br />
Capacity 8.1kg with 0.1g readability. Sample size selectable 5~100. Can do<br />
taring, percent and dynamic weighing. Powered by battery eliminator.<br />
A&D Mercury HL400 Scale 400g x 0.1g<br />
AND,HL400 AU<br />
battery operated balance, range 400g, resolution 0.1g<br />
A&D GR-202 Mercury Dual Range Analytical Balance<br />
AND,GR-202 AU<br />
Two-layer construction, splash-proof keyboard and front operating doorlever.<br />
Range 210g x 0.1mg & 42g x 0.01mg. One-touch calibration and<br />
automatic self-calibration outside preset temperature limits. Functions<br />
include multiple weighing units, counting or %, data memory, adjustable<br />
environment setting and GLP management. Bidirectional RS232C standard.<br />
Low-voltage operation with ac adaptor.<br />
Mettler 15kg Weighing Scales<br />
MET,15KG MY<br />
Mettler 60kg Weighing Scales<br />
MET,60KG MY<br />
PHYSICAL MEASUREMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 87
NON-DES<strong>TR</strong>UCTIVE TESTING<br />
88<br />
vibratiOn & alignment analySiS<br />
Model Type Application Features<br />
ARL,EL-235 Ground vibration logger<br />
BK,2635 Accelerometer charge amp<br />
Monitoring vibration for<br />
pile driving and general<br />
construction vibration<br />
Logging outdoors<br />
enclosure<br />
bK,4230 Sound level meter calibrator NATA<br />
bK,4333<br />
Frequency<br />
Range<br />
(Hz)<br />
2~10,000<br />
Max<br />
Acceleration (G)<br />
bK,4343<br />
BK,8301<br />
Accelerometer<br />
2~12,000<br />
10,000<br />
bK,4370<br />
0.2~5,4kHz 2,000<br />
bK,4371<br />
Single axis accelerometer<br />
0.2~12.7kHz 20,000<br />
pCb,300A20 Low G will operate down to DC dc~300 20<br />
TEx,ATM<br />
Blast logger and ground vibration<br />
logger<br />
Explosion and general<br />
construction vibration<br />
monitoring<br />
Logging outdoor<br />
enclosure, tri-axial<br />
geophones<br />
bLA,UMx-SM-6 Blast logger Explosion monitoring Tri-axial geophones<br />
CSI,UL<strong>TR</strong>ASpEC Balancing system & vibration analysis Balancing & spectral analysis<br />
LAb,LW-140-141<br />
Vibration table (requires frequency<br />
source)<br />
Shake source for testing<br />
purposes<br />
pRU,ROT<br />
pRU,ROT-UL<strong>TR</strong>A<br />
Optical machinery shaft alignment<br />
Allow for the alignment of non<br />
rotating shafts<br />
RIO,Cp-10 Printer For use with RIO,VA-10<br />
RIO,VA-10<br />
RIO,VA-11<br />
Vibration analyser Machinery condition monitoring<br />
RIO,VM82 Vibration meter Machinery and monitoring<br />
SVA,912A & SVA,SV06A Tri-axial accelerometer & analyser<br />
TIN,SHOCKSET Single axis shock logger<br />
Whole body vibration<br />
measurement<br />
Shipping and packaging<br />
analysis<br />
Includes thermal<br />
growth analysis<br />
Hand held<br />
accelerometer<br />
Hand held & magnetic<br />
accelerometer<br />
PC memory card<br />
capability<br />
Magnetic<br />
accelerometer<br />
Includes whoopee<br />
cushion<br />
Logging capability<br />
4.5~500<br />
PIE,308B Accelerometer with amp 1~3kHz<br />
MAD,SHOCK101 Tri-axial bump Logger<br />
Pruftechnik Rotalign Ultra Laser Shaft Alighment<br />
pRU,ROT-UL<strong>TR</strong>A AU<br />
Laser based rotating shaft alignment system. Maximum separation between<br />
emitter and receiver 10m. Aligns horizontal and vertical machines, aligns<br />
coupled and uncoupled shafts equally well. Ultra modern computer design,<br />
backlit colour display, Intel xScale 400MHz CpU, USb for peripheral devices,<br />
pC, printer, also bluetooth communication. backlit keyboard, rechargeable<br />
Li-Ion battery pack. Machine train alignment- 14 machines. Alignment<br />
results in 3 quick steps, thermal growth computation. Rotalign Ultra Reader<br />
software included.<br />
Logging vibration for<br />
transportation i.e. trucks,<br />
containers<br />
Tri-axial transportation<br />
logging<br />
+/-50
Pruftechnik 1500mm Length Tension Chains<br />
pRU,AL12.116 AU<br />
1500mm length tension chains for pRU,ROT-UL<strong>TR</strong>A.<br />
Pruftechnik Rotalign Shaft Alignment<br />
pRU,ROT AU<br />
Max alignment distance 10m. Aligns horizontal and vertical machines.<br />
Graphical display of alignment condition. Resolution 1micron, angular better<br />
than 10µRad.<br />
Pruftechnik Magnetic Sliding Bracket<br />
pRU,MAG-bRKT AU<br />
Designed to be used with the Rotalign. Used when shafts to be aligned<br />
cannot be rotated. A bracket is required for each non-rotating shaft to be<br />
aligned (ie. usually 2 will be required).<br />
Madgetech Ultrashock-EB Transportation Logger<br />
MAD,UL<strong>TR</strong>ASHOCK-Eb AU<br />
Ambient temperature, humidity, pressure and 3 axis shock acceleration<br />
logger. Ranges: -40~180ºC, 0-95%RH, 0~30pSIA (0-200kpa), -50g~50g.<br />
Memory 23,831 readings per channel. Logging interval from 1 reading per<br />
2s to 1 reading per 12h. Sampling rate 2ms. Includes RS232 interface and<br />
setting up, downloading, graphing software.<br />
Madgetech Shock101-EB <strong>TR</strong>-Axial Transportation Logger<br />
MAD,SHOCK101 NZ<br />
battery powered, stand alone 3-axis shock recorder, extended battery life of<br />
up to 60 days typical. Measures and records shock as the peak acceleration<br />
levels over the user defined interval. Designed for documenting dynamic<br />
environments such as moving vehicles, containers, ships, etc.<br />
Tiny Tag, Set of 6 Loggers: 3 x Shock, 2 x Temperature,<br />
1 x Humidity<br />
TIN,SHOCKSET AU<br />
For shipping and transport testing. Includes 3 x shock loggers; these record<br />
the max G force in the programmed period. Includes a humidity logger,<br />
an internal temperature logger and temperature logger with external probe.<br />
Set also includes an f computer to download and view the results.<br />
Svantek 912A Sound Vibration Analyser<br />
SVA,912A AU<br />
Type 1 sound level meter including a single axis accelerometer. Provides<br />
standard sound measurements and vibration measurements including<br />
1/1 octave, 1/3 octave and full spectrum. Unit will store 1Mb of spectrum<br />
analysis information for waterfall plots etc. PC interface software included.<br />
Unit can make part body vibration measurements. If whole body vibration<br />
measurements are to be made the SVA,SV06A accessory must be used.<br />
Svantek SV06A Tri-axial Accel Interface for 912A<br />
SVA,SV06A AU<br />
Accessory kit for human whole body vibration measurement. provides<br />
4 accelerometer inputs for the SVA,912A and a tri-axial accelerometer<br />
‘whoopee cushion’ for whole body vibration. Can operate as an interface for<br />
a standard b & K tri-axial accelerometer.<br />
PCB Low G Accelerometer dc to 300 Hz<br />
pCb,300A20 AU<br />
Single axis accelerometer includes charge amplifier. Range ±20g,<br />
frequency (±5%) dc~300Hz, (±10%) ~500Hz. Shock limit ±5kg. Operating<br />
temperature -40~85OC. Weight 15g. Voltage sensitivity 100mV/g.<br />
B&K 2635 Charge Amplifier<br />
bK,2635 AU/MY<br />
built-in integrators for displacement and velocity. Sensitivity to 10V/pC.<br />
bandpass filters. Operates also from external 6~28Vdc or ±14Vdc. battery<br />
operated 100h life. Required with accelerometers.<br />
B&K 4333 Accelerometer<br />
bK,4333 MY<br />
Frequency range: 2~10,000Hz. Voltage sensitivity 14~24mV/g. Charge<br />
sensitivity 14-20pc/g. Maximum sinusoidal acceleration 7500g. Maximum<br />
shock 10,000g.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
vibratiOn & alignment analySiS<br />
B&K 4343 Accelerometer<br />
bK,4343 MY<br />
Accelerometer. Frequency range: 2~12,000Hz. Charge sensitivity 10~mV/g.<br />
Charge sensitivity 10pc/g. Maximum shock 10000g.<br />
B&K 4370 Accelerometer<br />
bK,4370 AU<br />
Frequency range 0.2Hz~5.4kHz. Voltage sensitivity 100mV/G or 8mV/ms2<br />
(approximately) into 20GΩ. Charge sensitivity 100pC/G or 10pC/ms2. Max<br />
sinusoidal acceleration 2,000G. Max shock 2,000G. Requires 1 charge<br />
amplifier.<br />
B&K 4371 Accelerometer<br />
bK,4371 AU/MY<br />
Frequency range 0.2Hz~12.7kHz. Voltage sensitivity 10mV/G or 0.8mV/Ms2<br />
(approximately) into 20GΩ. Charge sensitivity 10pC/G or 1pC/MS2. Max<br />
sinusoidal acceleration 6,000G. Max shock 20,000G. Requires 1 charge<br />
amplifier.<br />
B&K 8301 Accelerometer<br />
bK,8301 MY<br />
Accelerometer. Frequency range: 2~12000Hz. Sensitivity 10mV/g. Charge<br />
sensitivity 10pc/g. Maximum shock 10000g.<br />
B&K Vibration Impact Hammer<br />
bK,8202 AU<br />
For determining frequency response functions. Individually calibrated force<br />
transducer. Comes with 3 different tips and additional mass to enable pulse<br />
duration and frequency range to be determined.<br />
Piezotronics Accelerometer and Amplifier<br />
pIE,308b AU<br />
Accelerometer frequency range 1Hz~3kHz ±5%, 0.7Hz~6kHz ±10%,<br />
voltage sensitivity 100mV/g or 10.2mV/m/s2 ±2%. Range: ±50g, ±5V<br />
output, resolution 0.001g, vibration max 500G, shock max 5,000G. Supplied<br />
with pCb482A10 ICp line power unit.<br />
Linear Accelerometer +/-1G dc Response<br />
LIN,LSpC-1 AU<br />
Designed for very low force levels ±1G measurement range. Operates<br />
down to dc in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%.<br />
Shock Survivability 100g. Natural Frequency 100Hz.<br />
Rion VM82 Vibration Meter<br />
RIO,VM82 NZ<br />
Single axis. Measure acceleration from 0.02~200m/s2. Velocity from<br />
0.1mm~1m/s rms. Displacement from 0.001~100mm. AC/dc output of 1V<br />
full scale.<br />
Rion VA-10 Vibration Analyser<br />
RIO,VA-10 AU/MY<br />
Vibration analyser for rotating machinery. Measures acceleration, velocity<br />
and displacement. Stores 500 readings. LCD display with waveform,<br />
spectrum and data readout. Auto measurement function. Includes printer<br />
interface.<br />
Rion CP-10 RS-232 Printer VA10 NL05 NL14<br />
RIO,Cp-10 AU/MY<br />
printer for RIO,VA-10. Operates from optional NiCd battery pack.<br />
Rion VA-11 Vibration Analyser<br />
RIO,VA-11 AU/MY<br />
Includes 2 pickup types hand held (pV55) and magnetic type (pV57).<br />
Instrument will measure acceleration, velocity and displacement. Displays<br />
rms, peak and crest factor. Uses FFT to display power and vibration<br />
spectrum. Incorporates pCMCIA card flash memory for data storage. RS-232<br />
interface is available. Specifications pV57 1Hz~5kHz, pV55 3Hz~20kHz<br />
(velocity 3kHz, displacement 500Hz). Acceleration 0.02~316mm/s2 rms.<br />
Velocity 0.1~1,000 mm/s rms. Displacement 0.003~28.3 (EQ pp). High<br />
pass filter 3Hz, 10Hz & 1kHz. Low pass 1kHz, 5kHz & 20 kHz. Stores 500<br />
measurements.<br />
NON-DES<strong>TR</strong>UCTIVE TESTING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 89
NON-DES<strong>TR</strong>UCTIVE TESTING<br />
90<br />
vibratiOn & alignment analySiS<br />
Texcel ATM Explosion and Ground Vibration Logger<br />
TEx,ATM AU<br />
Triaxial geophone and overpressure (airblast) microphone with logger used<br />
to determine explosion and ground vibration characteristics. Geophone<br />
range to ±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s, 0.109mm/s<br />
up to 55.9mm/s. Microphone range 80-dbL~140dbL, resolution 0.049pa<br />
up to 122dbL (25pa), 0.40pa up to 140dbL (201pa). Sample rate 20, 50,<br />
100, 200, 500Hz & 1kHz. bandwidth: geophone 4.5Hz~500Hz, microphone<br />
2Hz~500Hz. Includes software and download cable. Internal memory 2Mb.<br />
power internal 12V dc 7Ah batteries. Continuous operation 240h. Supplied<br />
with 90~260V 50/60Hz charger, recharge time 8h approx. Instrument with<br />
16 character LCD display, built into weatherproof pelican enclosure, rated<br />
Ip65. Operating temperature range 0~70 O C, display 0~50 O C. Also supplied<br />
with alarm light, reset button and 2 x 15m cable, ideal for vibration sensitive<br />
construction projects. External dc power supply cable also supplied.<br />
glOSS meaSurement<br />
ARL EL-235 Tri-axial Ground Vibration Logger<br />
ARL,EL-235 AU<br />
Portable logger with human exposure capability. Monitors ground and<br />
building vibration for long periods. Calculates and stores tri-axial vibration<br />
stats, vector sum stats, peak particle velocity (ppV), rms particle velocity<br />
and human exposure (HEF) stats. Includes PC based analysis software.<br />
Sensor frequency response 1Hz~500Hz. Logs interval, date, time, Leq,<br />
Lmax, temperature, battery, L0.1, L1.0, L10 & L90. Event mode logs date,<br />
time, max and duration (Real time mode = 1000 samples/s). Stores up to<br />
4,096 intervals or events. power 70mA @ 12V.<br />
Blastronics UMX-SM-6 Explosion Logger<br />
bLA,UMx-SM-6 AU<br />
Triaxial geophones, microphone with logger used to determine explosion<br />
characteristics. Geophones auto-ranging to 110mm/s, resolution ±0.1.<br />
Microphone auto-ranging to 140dbL, resolution ±0.25db. Sample rate<br />
250, 500Hz & 1kHz. bandwidth geophones 4.5~500Hz. Microphone<br />
2~500Hz. Includes software and download cable. Internal memory 4Mb.<br />
power internal 6Vdc 2,600mAh Gel-cells, operating consumption 40mA,<br />
sleep mode 10mA. Continuous operation 65h, with 1w programmable timer<br />
schedule. Instrument has a display.<br />
Labworks LW-140-141 Vibration Table<br />
LAb,LW-140-141 AU<br />
Capable of random and sine movement. Sine force 489N, random force<br />
334N, shock force 1kN, max displacement 25mm, max velocity 17.8m/s,<br />
accel bare table 110g pk, accel 45kg 55g pk, accel 2.2kg 18g pk. Max accel<br />
resonant 150g pk, max accel peak shock 200g pk. Unit requires a signal<br />
source and an accelerometer to measure the acceleration. Signal source<br />
could be a function generator or random noise generator.<br />
Elcometer 402 Glossmeter<br />
ELC,402 AU<br />
Measures the gloss or specular reflection from a variety of surfaces. Range 0~199.9 gloss units per ISO 2813-1978. Measuring angles 60O & 20O. Aperture<br />
16 x 33mm ellipse. Digital display. Statistical functions – min, max, average, standard deviation. Stores up to 4,000 readings. RS232C interface for a printer.<br />
Operates from ac mains or internal rechargeable batteries.<br />
autOmOtive<br />
Translock Brake Tester and Light Transmittance Meters<br />
TLI,bTM2-LTM2 AU<br />
Kit contains a brake tester and a light tester check vehicle conformance for the NSW Road Worthy Certificate. brake tester measures the deceleration rate of<br />
the vehicle and the light tester measures the transmission levels of light through the windscreen.<br />
nOn-deStructive teSting<br />
> NEW<br />
Panametric NDT Epoch-LT Ultrasonic Flaw Detector<br />
pAN,EpOCH-LT AU<br />
Handheld flaw detector with fast and bright LCD mono display, update rate<br />
60Hz, automated transducer calibration. Display freeze holds waveform and<br />
soundpath data, soundpath data viewable in inch, mm or microseconds. peak<br />
memory feature, RF display mode, alarms, theshold positive/negative, or<br />
minimum depth. Numeric data logger. EMAT probe compatibility (E110-Sb).<br />
Standard DAC and TVG. Software options fitted- Echo-Echo and Square<br />
wave pulser. No probes supplied or connection cables. Refer pAN,<strong>TR</strong>AN-<br />
KIT.<br />
> NEW<br />
Panametric NDT Kit of 3 Transducers, Wedges & Cal Block<br />
pAN,<strong>TR</strong>AN-KIT AU<br />
Kit of 3 Ultasonic transducers, comprising 1x V540SM angle beam<br />
transducer 13mm, 2.25MHz, 1x V541SM angle beam transducer 13mm,<br />
5MHz, 1x Single crystal transducer, 0DEG, 13mm, 5MHz, 3x wedge, 1x<br />
45DEG, 1x 60DEG, 1x 70 DEG. 1x 1M lemo cable, 1x 5 step calibration<br />
block, 12.5, 10.0, 7.5, 5.0, 2.5mm (1018 steel).<br />
Phynix Ferrous/Non Ferrous Coating Thickness Tester<br />
pHY,SURFIx FN AU<br />
Thickness tester with memory and statistics. Supplied with external probe,<br />
calibration standards and carry pouch. Measurement range 0~1,500µm or<br />
0~60mils (selectable), tolerance ±1µm +3% of reading, resolution 0.1µm.<br />
Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min<br />
substrate thickness type F 0.5mm, type N 50µm. Calibration factory, zero,<br />
foil. Data memory 80 readings max. Interface infra-red down load data to<br />
PC utilising hyper terminal.
Defelsko FNS2 Ferrous & Non Ferrous Coating Thickness<br />
Tester<br />
DEF,FNS2 AU<br />
Storage of up to 250 readings. Supplied with external probe, calibration<br />
standards and carry pouch. Measurement range 0~1.5m or 0~60mils<br />
(selectable), tolerance 0~50mm ±1mm, +1% of reading, greater than 50mm<br />
±2µm, +1%, resolution 0.1mm. backglow display, HiLo limits audible and<br />
visible alerts when measurements exceed specified limits. Continually<br />
displays updates average, standard deviation, min/max thickness and<br />
number of readings while measuring. Hi resolution mode for greater<br />
precision. Built in infra red port for down loading data.<br />
Elektrophysik Mini-100FN Coating Thickness Meter<br />
ELE,MINI-100FN AU<br />
Measuring range 0~1500µm, tolerance ±2µm or 3% of reading. Operates<br />
on both ferrous and non-ferrous substrates.<br />
Defelsko POS100-C3 Ultrasonic Thickness Gauge<br />
DEF,pOS100-C3 AU<br />
Measure coatings on concrete, paint and lacquer on wood, paint on plastic,<br />
paint on glass, glazing on ceramic, floor coatings, etc. Range 50µ~4.5mm<br />
±2µ, ±3% of reading. Calculates max, min, mean, tolerance and SD. Stores<br />
1,500 readings in 100 groups for statistical calcs. PC interface & software.<br />
Battery operated.<br />
Defelsko Positest Pull Off Adhesion Tester for Concrete &<br />
Metal<br />
DEF,pOSITEST AU<br />
Measures the force required to pull a specified test diameter of coating away<br />
from its substrate using hydraulic pressure. Pressure is displayed in both<br />
MPa and PSI on a precision dial indicator and can be related to the strength<br />
of adhesion to the substrate. Suitable for coatings on both metal and<br />
concrete surfaces. Conforms with standards ASTM D4541 and ISO 4624.<br />
> NEW<br />
PCWI High Voltage Pulse Crest Meter<br />
pCW,HV-pULSE CREST AU<br />
Measure and indicate peak voltage.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
nOn-deStructive teSting<br />
> NEW<br />
PCWI 40kV Pulse Porosity (Holiday) Detector<br />
pCW,p40-pULSE AU<br />
Pulse porosity (Holiday) detector. Detects pinholes in coatings and wrapping<br />
above 150µm on metal substrates such as pipes and tanks. Can be used<br />
on dry or wet surfaces. 0~40kV output, 4 digit LED display of voltage, alarm<br />
sensitivity setting between dry and wet. Supplied with rechargeable battery,<br />
10h charger, red probe handle and 2m length of rubber coated cable, 60mm<br />
connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat<br />
brass wire brush, 450mm probe extension and 80mm probe extension.<br />
PCWI Hi-Lighter Holiday Detector<br />
pCW,HI-L AU/NZ<br />
Detects pinholes in coatings and wrappings on metal substrates such as<br />
pipes and tanks. 0~20kV, 3½ digit LCD display of voltage, variable alarm<br />
level. Portable with rechargeable batteries, includes probe and handle,<br />
extension probes and a variety of brass wire brushes for both flat and curved<br />
surfaces such as pipes.<br />
PCWI 30kV DC Porisity (Holiday) Detector<br />
pCW,DC30 AU<br />
DC Porosity (Holiday) detector. Detects pinholes in coatings above 150um<br />
on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display<br />
with battery indicator, display of voltage level. Alarm indicated on front panel,<br />
supplied with rechargeable battery, 10h charger, probe handle with neon<br />
and 2m length cable, 60mm connector for flat brushes, 7m earth cable with<br />
clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension.<br />
Dry conditions.<br />
PCWI 40kV Pulse Porosity (Holiday) Detector<br />
pCW,DC30-pULSE AU<br />
Pulse Porosity (Holiday) detector. Detects pinholes in coatingsand wrapping<br />
above 150um on metal substrates such as pipes and tanks. Can be used<br />
on dry or wet surfaces. 0-40kV output, 4 digit LED display of voltage, alarm<br />
sensitivity setting between dry and wet. Supplied with rechargeable battery,<br />
10 hr charger, red probe handle and 2m length of rubber coated cable, 60mm<br />
connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat<br />
brass wire brush, 450mm probe extension and 80mm probe extension.<br />
Mitutoyo S-211 Surface Roughness Gauge<br />
MIT,S-211 AU<br />
Surface roughness tester comprising an LCD display and a detachable<br />
detector/drive unit. parameters measured in Ra, Rz, and Rmax units. Tip<br />
radius 5mm. Data output. NiCd batteries.<br />
Mitutoyo SJ-201P Surface Roughness Tester<br />
MIT,SJ201-NATA AU<br />
Comprises LCD display and a detachable detector/drive unit. parameters<br />
measured in Ra, Rq, Ry, Rz, Rt, Rp, R3z, Rk, Rpk, Rvk, S, Sm, pc, mr, Mr1,<br />
Mr2, A1, A2, Vo units. Ranges: 350, 100, 50µm & 10µm, resolution from<br />
0.01~0.4µm. Tip radius 5mm. Data output. NiCd batteries.<br />
NON-DES<strong>TR</strong>UCTIVE TESTING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 91
NON-DES<strong>TR</strong>UCTIVE TESTING<br />
92<br />
nOn-deStructive teSting<br />
Mitutoyo 293-330 Digital Micrometer<br />
MIT,293-330 AU<br />
Water resistant and coolant proof (IP65) digimatic micrometer, measuring<br />
range 0~1”, 0~25mm. Resolution .00005”, 0.001mm , quantizing error<br />
±1 count, LCD display. Temperature operating range 5~40OC, storage -<br />
10~60OC. button settings: origin, zero/AbS, inch/mm, hold.<br />
Panametrics 26 mg Pocket Thickness Gauge<br />
pAN,26MG AU/NZ<br />
Range 1~500mm, fast min mode. Resolution 0.01mm. probe operates -<br />
20~150OC. Panametrics NDT 37DL-Plus Ultrasonic Thickness Gauge<br />
pAN,37DL-pLUS AU<br />
Thickness gauge with large display (A-scan), which will display the returned<br />
waveform. It has echo-echo through-paint capability. Supplied with WIN37DL<br />
pLUS software and cable. The supplied probe is 11 mm diameter with a<br />
1~500 mm operating range and a -20~500OC temperature operating range.<br />
The instrument has a MIL-STD-810E hazardous area operation.<br />
cOncrete teSting equipment<br />
ELE Type EL35-2020 Concrete Cover Meter<br />
ELE,EL35-2020 AU/NZ<br />
Non-destructive measurement of concrete thickness above steel<br />
reinforcement rods. Measures rod diameter. Depth range 360mm for rod<br />
diameters 6~40mm & 200mm depth for rod up to 6mmØ. Small search<br />
head 80H x 50mmØ. provides a high resolution capability when mapping<br />
out reinforcement structures. Range 100mm with 6mm bar to 120mm with<br />
40mm bar. battery operated.<br />
Profometer-4 Rebar Locator<br />
pRO,pROFO-4 MY<br />
Rebar locator.<br />
Steinkamp BP7 Ultrasonic Concrete Tester<br />
STE,bp7 AU<br />
Measures the time a signal takes to propagate through a material. Used for<br />
concrete refractory bricks, tile (fired and unfired), outcropping rocks, tunnel<br />
walls, frozen ground, electrolytic carbon, plastics, adhesion, cast iron and<br />
wood etc. Technique relies on the fact that the pulse velocity relates to the<br />
materials tensile strength. Instrument can be used to determine % steel in<br />
concrete, variations in the moisture content, measurements of crack depth,<br />
voids, etc.<br />
Panametrics 36DL Plus Thickness Gauge<br />
pAN,36DLpLUS AU<br />
Large display (A-scan), which displays the returned waveform. Echoecho<br />
through-paint capability. Supplied with WIN95 software and cable.<br />
Supplied probe is 11mmØ with 1~500mm operating range and -20~500OC temperature operating range. Instrument has a MIL-STD-810E hazardous<br />
area operation.<br />
Panametrics 25DLHP Thickness Gauge<br />
pAN,25DLHp AU<br />
Designed for fiberglass, rubber composites and castings. Measures<br />
standard steel, copper, etc. Does echo-echo measurements. Measures<br />
the thickness of material under paint, etc. built in 5,000 reading datalogger<br />
and an RS232 port.<br />
Krautkramer DMS Thickness Gauge<br />
KRA,DMS AU<br />
Complete with echo verification and logger. Includes high temperature probe<br />
and cable. Incorporates a wave form display for accurate assessment of<br />
material under test, measurement of thickness whilst ignoring external paint.<br />
probe will operate to 200OC without cooling, up to 540OC with cooling.<br />
Measurement ranges 0.75mm~250mm (for different ranges other probes<br />
are available). Resolution 0.01mm. Stores up to 80,000 readings or 1,200<br />
readings with full waveform information.<br />
Sonatest Thickness Gauge<br />
SON,T-GAGE-IV+ AU/MY<br />
Range 0.63~500mm, resolution 0.01mm, high speed scanning mode,<br />
selectable backlight, alarm mode, differential mode, RS232C output,<br />
data send using hyper terminal. Supplied with high temperature probe,<br />
temperature range 0~340ºC.<br />
Protimeter SM Moisture Meter<br />
pRO,SM AU<br />
Moisture meter for survey work. Very good for determining wet points. Can<br />
be used on both concrete and timber. Subsequent accurate measurements<br />
can then be made.<br />
Proceq LR Concrete Test Hammer<br />
pRO,LR AU<br />
Concrete hardness tester (Schmidt hammer). Supplied with in-built<br />
mechanical chart recorder. Impact energy 0.735Nm, 0.075kgm. For concrete<br />
thickness less than 100mm.<br />
Protimeter CMIII Concrete Moisture Meter<br />
pRO,CMIII AU<br />
Measures concrete moisture content using 2 methods. Firstly using<br />
impedance as a direct instant method. Secondly an accurate method<br />
requiring placing a box on the concrete and measuring the humidity<br />
generated by the concrete.
Protimeter Moisture Measurement System<br />
pRO,MMS-pLUS AU<br />
Moisture meter for detection of moisture in non conductive solid materials<br />
such as wood and masonry. Two measurement modes, search for qualitaive<br />
measurements and measure mode for precise and locaised moisture<br />
content. Supplied with pin type probes, deep wall probes, hygrometer probe<br />
and extention cord,for RH, ambient temperature or dew point temperature.<br />
Hygrostick probe supplied for surface temperature measurement. Logging<br />
software and RS232 computer interface supplied.<br />
Proceq 2000-ND Digi Schmidt Test Hammer<br />
pRO,2000-ND AU<br />
Concrete hardness tester (Schmidt hammer). Supplied complete with inbuilt<br />
graphical LCD for setting up and graphical display of results,up to 500 results<br />
can be stored. RS232 interface and software supplied for down loading.<br />
Impact energy 2.207Nm. Engineering units of results in N/mm2, Mpa, psi,<br />
kg/cm2. For concrete thickness greater than 100mm.<br />
Olsen FTG Concrete Thickness Gauge<br />
OLS,FTG AU<br />
Concrete thickness gauge utilising the impact Echo test method. Can<br />
measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m.<br />
This concrete thickness gauge is a battery operated handheld system for<br />
measuring the flaws and thickness of concrete slabs, pavements, walls and<br />
other plate-like structures from one side. Up to 300 readings can be stored<br />
in the field before the memory is full. RS232 interface and transfer software<br />
supplied.<br />
Krautkramer DynaPocket Rebound Hardness Tester<br />
KRA,DYNApOCKET AU<br />
based on the Leeb’s method HL, utilising a 3mm tungsten carbide ball.<br />
Other hardness scales can be selected, HS Shore, Hb brinell, HRb Rockwell<br />
b, HRC Rockwell C, HV Vickers and N/mm 2 tensile strength. Choice of 9<br />
material groups can be selected, they are St Low-alloy/unalloyed steel and<br />
cast steel, ASt Tool steel, SSt Corrosion resistant steel, GCI Gray cast iron,<br />
NCI Nodular graphite cast iron, AL Aluminium cast alloys, brS brass, brZ<br />
bronze, Cu Wrought copper alloys.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
cOncrete teSting equipment<br />
Hilti PS20 Rebar, Copper Pipe & Electrical Cable Locator<br />
HIL,pS20 AU<br />
Localise and position of reinforcement, (rebars) copper, aluminium pipes<br />
and unshielded live electric cables. Depth range for detection of rebars<br />
0~100mm, for copper & aluminium pipes 60mm, rebar diameter 8~36mm,<br />
depth detection accuracy 10~30mm ±2mm, above 30-60mm ± 2mm ±10%<br />
depth, above 60~80mm ±5mm ±10% depth, based on 12mm rebars.<br />
Detection of copper & aluminium pipes based on 10~30mmØ, only detection<br />
with depth of 0~60mm, no depth reading, same for live electric cables,<br />
cannot detect live cables in metal conduit or shielded cables.<br />
Hilti Ferroscan Concrete Reo Scanner<br />
HIL,FERROSCAN AU<br />
Reinforced concrete imaging system. Displays depth of concrete coverage,<br />
location of reinforcement rods and anchor setting points. Fast, simple<br />
operation. Depth mode allows reinforcement rods at different depths to<br />
be viewed. Printer interface and PC interface and software allow images<br />
to be printed and/or stored for further use. Depth coverage up to 180mm.<br />
Reinforcement rod diameter measurement range 6~36mm. Area covered<br />
in a single measurement run 600 x 600mm; 42 image memory allows total<br />
15m 2 coverage without downloading.<br />
hardneSS teSterS<br />
Proceq Equotip Hardness Tester<br />
pRO,EQUOTIp AU<br />
Test probe on a flexible lead. Probe type D is standard catering for most<br />
materials. Measurement ranges steels 80~650Hb, 80~940HV, 20~68HRC,<br />
aluminium castings 20~160Hb, cast iron 90~380Hb, brass 40~170Hb &<br />
copper wrought alloys 43~315Hb. Test hardness must not exceed 940HV.<br />
Battery operated.<br />
Bareiss HPE FM02177 Shore A Hardness Tester<br />
bAR,HpE-FM02177 AU<br />
Durometer tester for general rubber, elastomer, soft plastic, tires, rubber<br />
rolls & rubber hoses. Surface min 35mmØ, material thickness of 6mm are<br />
necessary for a hardness test according to the standards. Hardness tests<br />
can be conducted in a vertical, horizontal positions and on places which are<br />
difficult to reach. Test time setable from 0~30s. Reading exactness of ±0.5<br />
Shore and according to set down standards deviation of ±1 Shore.<br />
NON-DES<strong>TR</strong>UCTIVE TESTING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 93
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
94<br />
induStrial calibratOrS<br />
Model Type<br />
Analog<br />
Out<br />
Pressure<br />
(Bar)<br />
Vacuum<br />
(Bar)<br />
Battery RS232 Accuracy %<br />
AMb,CAL-20MpA Pressure pneumatic 200 0.5 fs<br />
AME,HL2700N Dead weight tester hydraulic 225 0.05 reading<br />
AME,ppCE-NATA* Pressure hydraulic 700<br />
Current<br />
mA<br />
0.04 reading 50<br />
bEA,bIC200 Industrial incl. Pressure 1 100 50<br />
DRU,DpI603-10-NATA*<br />
10<br />
Current<br />
Source mA<br />
DRU,DpI603-20 20<br />
0.85 0.075 fs<br />
55<br />
DRU,DpI603-2NATA* 2<br />
Pressure pneumatic<br />
DRU,DpI603-20NATA* 20 Yes<br />
55<br />
DRU,DpI610-20NATA* Yes Yes 0.025 fs 24<br />
Yes<br />
DRU,DpI610-160 160 0.025 fs 24<br />
DRU,UpS-3<br />
0.01 24<br />
Current loop<br />
DRU,UpS-IS 0.25 55<br />
FLU,725<br />
FLU,725-NATA*<br />
FLU,743b<br />
FLU,744 Industrial (hart)<br />
FLU,700S/W-DpC-<br />
<strong>TR</strong>ACK<br />
Industrial 110 22<br />
S/ware for Fluke 743b & 744<br />
GRA,W6-NATA* Water bath 0.1<br />
HAL,KAL84 Very low pressure 10 Yes Linearity ±0.5%<br />
DRU,DbC150TC<br />
HAR,9100-A 0.5°C<br />
HAR,9105-NATA*<br />
Dry well temperature<br />
HAR,9107-NATA* Yes 0.1°C<br />
HAR,9141-NATA* 0.5<br />
JOF,LpC-NATA* Pressure Yes 10 0.8 Yes 0.1 fs 200m<br />
SER,NOVA-1 Dry well temperature 0.1°C<br />
SI,pC6-2-NATA*<br />
SI,pC6-20-NATA* Pressure pneumatic<br />
20<br />
YES<br />
SI,pC6-40-NATA* 40<br />
Sp,pC6-1000-NATA*<br />
2 0.85<br />
1.0<br />
Yes<br />
0.3°C<br />
0.1<br />
Yes Yes 0.025 fs 50 50<br />
HAR,9150 Thermocouple furnance No Yes ±0.5°C<br />
HAR,9170-R-NATA* Metrology well calibrator Yes ±0.01°C<br />
HAR,3125-NATA*<br />
Temperature surface probe<br />
calibrator<br />
Yes<br />
±0.5°C~200°C,<br />
±1%~400°C<br />
JOF,1200SE Temperature calibrator 150~200°C<br />
HAR,7102-NATA*<br />
HAR,7103-NATA*<br />
FLU,718<br />
Temperature micro bath Yes ±0.25°C<br />
SI,pC6-pRO 350 350<br />
Pressure calibrator<br />
DRU,DpI610-2-NATA* 2 -1 Yes 0.025°C ±55 0~24<br />
DRU,DpI610-400-NATA* 400 Yes 0.025°C ±55 0~24<br />
* Nata Calibrated<br />
SI,HTP1<br />
1,000<br />
Pressure pump<br />
SI,TpI-40 40 -1<br />
Yes
Model Type<br />
Freq<br />
kHz<br />
Freq<br />
Source<br />
kHz<br />
Loop<br />
Power<br />
V<br />
Resist<br />
Measuremt<br />
RTD/<br />
TC<br />
Temp<br />
Source °C<br />
AME,ppCE-NATA* Pressure hydraulic 30<br />
bEA,bIC200 Industrial incl. Pressure 48 200Ω 100<br />
DRU,DpI603-10-NATA*<br />
DRU,DpI603-20<br />
DRU,DpI603-2NATA*<br />
induStrial calibratOrS<br />
Voltage<br />
Max V<br />
50<br />
Voltage<br />
Source V<br />
DRU,DpI603-20NATA*<br />
DRU,DpI610-20NATA*<br />
DUR,DpI610-20IS<br />
Pressure pneumatic 24<br />
DRU,DpI610-160 24 10<br />
DRU,UpS-3<br />
DRU,UpS-IS<br />
Current loop<br />
FLU,701-NATA*<br />
500<br />
FLU,725<br />
FLU,725-NATA*<br />
Industrial<br />
50 5<br />
24 11kΩ Yes 300 11<br />
FLU,743b<br />
FLU,744 Industrial (hart)<br />
500<br />
FLU,700S/W-DpC-<br />
<strong>TR</strong>ACK<br />
S/ware for Fluke 743b & 744<br />
GRA,W6-NATA* Water bath 0~150<br />
HAL,KLA84 Very low pressure<br />
DRU,DbC150TC<br />
-45 (below amb) ~ 150<br />
HAR,9100A 40~300<br />
HAR,9105-NATA*<br />
HAR,9107-NATA*<br />
Dry well temperature<br />
40~650<br />
-45~140<br />
HAR,9141-NATA* 40~650<br />
SER,NOVA-1<br />
SI,pC6-2-NATA<br />
200~1,000<br />
SI,pC6-20-NATA*<br />
SI,pC6-40-NATA*<br />
Pressure pneumatic<br />
24 24 10<br />
Sp,pC6-1000-NATA* Pressure Hydraulic<br />
HAR,9150 Thermal couple furnance 150~1,200<br />
HAR,9170-R-NATA* Metrology well calibrator -45~140<br />
HAR,3125-NATA*<br />
Temperature surface probe<br />
calibrator<br />
35~400<br />
JOF,1200SE Temperature calibrator 150~1,200<br />
HAR,7102-NATA*<br />
HAR,7103-NATA*<br />
FLU,718<br />
Temperature micro bath<br />
-5~125<br />
-30~125<br />
SI,pC6-pRO 350<br />
DRU,DpI610-2-NATA*<br />
Pressure calibrator<br />
+50 10,24<br />
DRU,DpI610-400-NATA* +50 10,24<br />
SI,HTP1<br />
SI,TpI-40<br />
* Nata Calibrated<br />
Pressure pump<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 95
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
96<br />
induStrial calibratOrS<br />
Fluke 5500A Multi Product Calibrator with NATA Calibrated<br />
FLU,5500A-NATA AU<br />
Calibrator sources direct voltage & current, alternating voltage and current,<br />
with multiple waveforms and harmonics, 2 simultaneous voltage outputs<br />
or voltage & current. Simulates power with phase control, resistance,<br />
capacitance, thermocouples and RTDs. Selectable ranges include the<br />
following outputs Vdc from 0~1.02kV, Vac from 1mV~1.02kV with output from<br />
10Hz~500kHz. AC current from 0.01µA~11A with output from 10Hz~10kHz.<br />
DC current from 0~11A. Resistance values from short circuit to 330MΩ.<br />
Capacitance values from 330pF~1,100µF. Temperature t/c b, C, E, J, K, L,<br />
N, R, S, T, U, RTD pt385 100Ω, pt3926 100Ω, pt3916 100Ω, pt385 200Ω,<br />
pt385 500Ω, pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.<br />
Fluke 725 Process Calibrator<br />
FLU,725 NZ<br />
DC voltage measurement 0.025%, 300V max, source 0.02%, 11V max.<br />
DC current measurement 0.025%, 110mA max, source 0.01%, 22 mA<br />
max. Resistance measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ<br />
max. Frequency measurement 5 counts 1Hz~50kHz, source 1 count<br />
20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC. pt100<br />
RTD measurement 0.5ºC, source 0.2ºC. Measures and simulates 4~20mA,<br />
t/c E, N, J, K, T, b, R, S, & C, 2, 3 & 4 wire RTDs and frequency. Operates<br />
from drycell batteries.<br />
Fluke 725 Process Calibrator NATA Calibrated<br />
FLU,725-NATA AU<br />
Specification as above but with NATA calibration.<br />
Fluke 743 Calibrator<br />
FLU,743b AU/MY<br />
Includes RS232 interface. DC voltage measurement 0.025%, 300V max,<br />
source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,<br />
source 0.01%, 22mA max. Resistance measurement 0.05%, 11kΩ max,<br />
source 0.01%, 11kΩ max. Frequency measurement 0.5%, +5, 40~500Hz,<br />
source 1 count 20Hz~5kHz. ‘K’ thermocouple measurement 0.3ºC, source<br />
0.3OC pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and<br />
simulates 4~20mA, t/c E, N, J, K, T, b, R, S, & C, 2, 3 & 4 wire RTDs,<br />
frequency, test limit switches. Can use scaling factors for measurement &<br />
source. built in calculator. Autostep function. Allows user entered values.<br />
Operates as a 8k point data logger. Note pC software only supports 15<br />
tags.<br />
Fluke 744 DOC Calibrator with Hart<br />
FLU,744 AU/NZ/MY<br />
Documenting process calibrator which includes HART communication<br />
protocols for communicating with and setting up smart transmitters. RS232<br />
interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V<br />
max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA<br />
max. Resistance measurement 0.05%, 11kΩ max, source 0.01% 11kΩ max.<br />
Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’<br />
thermocouple measurement 0.3ºC, source 0.3ºC pt100. RTDs measurement<br />
0.3ºC, source 0.1ºC. Measures and simulates 4~20 mA, t/c E, N, J, K, T, b,<br />
R, S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling<br />
factors for measurement & source. built in calculator. Autostep function.<br />
Allows user entered values. Operates as an 8k point data logger. Note pC<br />
software only supports 15 tags.
Fluke 700 Pxx Series Pressure Modules<br />
FLU,700pxx NZ<br />
Assortment of pxx series pressure modules for the Fluke 741/744 process<br />
calibrators.<br />
Druck DBC150TC Dry Well Calibrator Calibrator<br />
DRU,DbC150TC AU<br />
Temperature range -45(below ambient)~150ºC. Accuracy 0.3ºC, resolution<br />
0.01ºC, stability 0.03ºC. Well standard insert supplied 145mm deep, 5, 6.6<br />
& 9.8mmØ. Heating time 14min 20~120ºC, cooling time 22min 25~-20ºC.<br />
Calibrator also measures sensor outputs, it can measure 5 types of RTD<br />
& 11 types of thermocouple. Supports 2, 3, 4 wire RTD and provides cold<br />
junction compensation for thermocouples.<br />
Hart 9105 Dry Block Temperature Calibrator -25~140ºC NATA<br />
HAR,9105-NATA AU<br />
HAR,9105 MY<br />
Range -25~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232<br />
interface for ramp and soak programming. Well dimensions 150mm deep,<br />
19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.<br />
Hart 9107 Dry Block Temperature Calibrator -45~140ºC NATA<br />
HAR,9107-NATA AU<br />
Range -45~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232<br />
interface for ramp and soak programming. Well dimensions 150mm deep,<br />
19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.<br />
> NEW Hart 9170-R Metrology Well Calibrator with Built-in<br />
Reference & NATA Certification<br />
HAR,9170-R-NATA AU<br />
Temperature range -45~140ºC with bult in reference thermometry. Reference<br />
input accepts (not supplied) 100, 25 and 10ohm pRT’s. Display accuracy +/-<br />
0.1ºC, stability +/-0.005ºC full range, resolution 0.001ºC. Well depth 6.3”,<br />
insert type A 1/4, 3/16, 1/4, 1/8, 1/4, 3/8”. Large LCD, numeric keypad and<br />
on screen menus. Heating time 32min 23~140ºC, 45 minutes -45~140ºC,<br />
cooling time 44min 23~-45ºC, 19min 140~23ºC. Supplied with RS232C<br />
interface and CD-ROM software.<br />
Hart 9100-A Dry Block Temperature Calibrator 30~300OC<br />
HAR,9100-A NZ<br />
Stability is 0.2ºC @ 50OC & 0.3ºC @ 300ºC. Accuracy for 35~200ºC ±0.5<br />
for 200~300ºC ±1, for well holes greater than ¼” ±2ºC.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
induStrial calibratOrS<br />
> NEW Hart 3125 Surface Probe Calibrator 35~400ºC NATA<br />
Certification<br />
HAR,3125-NATA AU<br />
Temperature range 35~400ºC. Display accuracy ±0.5~200ºC, ±1~400ºC.<br />
Stability ±0.2~300ºC, ±0.3~400ºC. Resolution 0.01º. Heating time<br />
25~400ºC 22min. Cooling time 400~100ºC 65min. Temperature surface<br />
plate 3.8ӯ accessible.<br />
Hart 9141 Dry Block Temperature Calibrator 50~650ºC<br />
HAR,9141-NATA AU<br />
Range 50~650ºC, basic accuracy 0.5% (holes > ¼” 2ºC). Insert hole sizes<br />
1/16”, 1/8”, 3/16”, ¼”, 3/8” & ½”. Includes pC software and interface cable.<br />
Heating time 1min to 650ºC. Cooling 25min from 650ºC~100ºC. Well depth<br />
4.875”. Stabilization time 7min.<br />
Hart 9150 Furnace 150-1200ºC<br />
HAR,9150 AU<br />
Temperature range 150~1200ºC. Stability ±0.5ºC, display accuracy of ±5ºC<br />
across entire range. Display resolution 0.1º~999.9ºC, 1º above 1,000ºC.<br />
Well diameter 1.25”, well depth 5.5”, insert type A. 1/16”, ¼”, ⅜”, 3/16”, ⅛”,<br />
½”. Heating time 35min to 1,200ºC, cooling time 140min.<br />
Jofra 1200SE Precision Temperature Calibrator<br />
JOF,1200SE MY<br />
Lightweight, portable for lab and general use. Simple single step zero setting.<br />
Temperature range 300~1200ºC. Excellent performance characteristics.<br />
Accuracy +2ºC. Stability +0.5ºC. Display in ºC or ºF to 0.1 resolution. Fast<br />
cooling and heating. User-selectable slope rates for controlled thermo switch<br />
testing. Self diagnostics includes semi-auto Switch Test & Hysteresis Test.<br />
Grant W6 Temperature Bath NATA Certified<br />
GRA,W6-NATA AU<br />
Water/oil bath calibrator for calibrating temperature probes. Ranges water<br />
ambient 100ºC; silicon oil ambient; 150ºC. Requires 3L oil (not supplied).<br />
Digital temperature controller and display. Stability 0.004ºC. Uniformity<br />
0.01ºC. Display resolution 0.1ºC. Tank size 300w x 150d x 150hmm.<br />
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 97
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
98<br />
induStrial calibratOrS<br />
> NEW<br />
Hart 7102 Temperature Micro Bath -5~125ºC<br />
HAR,7102-NATA AU<br />
Range -5~125ºC. Tank diameter 1.9”, 5.5” deep, volume 0.75L, includes<br />
tank lid. Accuracy ±0.25ºC, stability ±0.015ºC at -5OC, ±0.03ºC @ 121ºC,<br />
resolution ±0.01ºC. Heating time 25~100OC 30min, cooling time 25~0ºC<br />
30min. RS232C interface and CD-ROM sofware supplied.<br />
> NEW<br />
Hart 7103-NATA Micro Bath -30~125ºC NATA Certification<br />
HAR,7103-NATA NZ<br />
Temperature range -30~125ºC. Tank 2.5”Ø, 5.5” deep, volume 1L, includes<br />
tank lid. Accuracy ±0.25ºC, stability ±0.03ºC @ 25ºC, ±0.05ºC @ 125ºC,<br />
resolution ±0.01ºC. Heating time 25~100ºC 35min, cooling time 25~-20ºC<br />
45min. RS232C interface and CD-ROM software supplied.<br />
Druck UPS-IS Current Loop Calibrator<br />
DRU,UpS-IS AU<br />
Intrinsically safe 4~20mA source and measurement. provides 24V loop<br />
power. Accuracy 0.25%. Input and output resolution 10µA.<br />
Beamex BIC200 Instrument Calibrator<br />
bEA,bIC200 AU/MY<br />
For both electronic and pneumatic instruments. Output ranges settable to<br />
119.9% of range 0~10V, 1~5V, 4~20mA, 0~20mA, 10~50mA & 0~50mA.<br />
Output source for current ranges 24 & 48V. Input ranges to 4½ digit display<br />
100mV, 1, 10 & 100V, 100mA, 4~20mA, 200Ω. pressure measurement<br />
ranges 0~1bar & 0.2~1bar. Operates from internal NiCd batteries or external<br />
ac.<br />
Halstrup KAL84 0-1kPa Portable Pressure Calibrator<br />
HAL,KAL84 AU<br />
portable battery operated 0-1.000kpa (0-10mbar) low pressure calibrator.<br />
Linearity ±0.5% ±1 digit, hysteresis 0.1%, medium - air and all non<br />
aggressive gases, pressure connections 6.5mm hose NW5, interior tubing<br />
5mmØ. Analogue output 0-1V, display 41/2 digit, power supply via mains<br />
adaptor 100-240Vac & NiCd re chargable battery pack.<br />
> NEW<br />
Jofra C650 Calibrator<br />
JOF,C650 MY<br />
A fast, timesaving, and reliable true temperature calibrator designed for onsite<br />
use. produces temperatures between 33~650°C. Display resolution<br />
±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth 120mm x 28Ømm.<br />
Comes with a multi-hole insert of ⅜”,¼”, 3/16” & ⅛”Ø holes. Light weight<br />
and portable.<br />
Jofra LPC Pressure Calibrator NATA Calibrated<br />
JOF,LpC-NATA AU<br />
Range to 10bar (145psi). Display 4½ digit, can display in bar, psi, mercury &<br />
H Og. Analogue output 2Vdc. Includes adaptors ¼”bSp to various bSp &<br />
2<br />
NPT. Measures pressure and vacuum. Battery operated.<br />
Druck DPI603 2Bar Pressure Calibrator NATA Calibrated<br />
DRU,DpI603-2NATA AU<br />
Accuracy 0.075% fs includes pump for vacuum and pressure. pumps to<br />
20bar pressure & -850mbar vacuum. Measurements can be made to 2bar<br />
positive pressure & -1bar vacuum. Unit has a 24V energising voltage.<br />
Monitors loop current to 55mAdc loop voltage to 50V. Sealed to Ip65.<br />
Rechargeable battery operated. Displays in 24 different units. Interface<br />
1<br />
/8 ”bSp.<br />
SI PC6-2-NATA Pressure Calibrator & Pump -1~2Bar 0.025%<br />
Accuracy<br />
SI,pC6-2-NATA AU<br />
SI,pC6-2 MY<br />
Range -1~2bar. Measures voltage 0~100mV (1µV resolution), 0~5V (0.1mV<br />
resolution) & 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all<br />
at 0.025% accuracy. Will sources 0~10V (0.2mV resolution) & 0~50mA (1µA<br />
resolution) also at 0.025% accuracy. Voltage output regulated 10V ±0.1%,<br />
current 30mA and unregulated supply 24V ±10% current 50mA. pressure<br />
switch status. Complete with a full range of pressure connection adaptors.<br />
Record logging capability 444 and RS232 interface download to spread<br />
sheet files. Battery operation 10h or mains operation via charger.<br />
SI PC6 Pressure Calibrator & Pump 20 Bar 0.025% Accuracy<br />
SI,pC6-20-NATA AU<br />
basic accuracy 0.025%. Range output pressure to 20bar, output vacuum<br />
to -1bar. NATA certified Instrument. Measures voltage 0~100mV (1µV<br />
resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current<br />
0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />
resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage<br />
output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />
±10% current 50mA. pressure switch status. battery operation 10h or mains<br />
operation via charger. Complete with a full range of pressure connection<br />
adaptors.<br />
SI PC6-40-NATA Pressure Calibrator & Pump NATA Certified<br />
SI,pC6-40-NATA AU<br />
basic accuracy 0.025%. Range is 40bar. Measures voltage 0~100mV (1µV<br />
resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current<br />
0~50mA (1µA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />
resolution) & 0~50mA (1µA resolution) also at 0.025% accuracy. Voltage<br />
output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />
±10% current 50mA. pressure switch status. Complete with a full range<br />
of pressure connection adaptors. Record logging capability 444 and RS232<br />
interface download to spread sheet files. Battery operation 10h or mains<br />
operation via charger.
induStrial calibratOrS<br />
SI PC6-PRO 350Bar Pressure Calibrator & HTP1 Hydraulic<br />
Pump<br />
SI,pC6-pRO 350 MY<br />
Range 0~350bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV<br />
resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all<br />
@ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1µA<br />
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />
30mA & unregulated supply 24V ±10% current 50mA. pressure switch<br />
status. Pressure media oil, water & non corrosive gases. Battery operation<br />
10h or mains operation via charger. Complete with a full range of pressure<br />
connection adaptors.<br />
SI PC6 700Bar Pressure Calibrator & HTP1 Hydraulic Pump<br />
NATA Calibrated<br />
SI,pC6-700-NATA AU<br />
SI,pC6-700 MY<br />
Range 0~700bar. Measures 0~100mV (1µV resolution), 0~5V (0.1mV<br />
resolution), 0~50V (1mV resolution) & current 0~50mA (1µA resolution) all<br />
@ 0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA (1uA<br />
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />
30mA & unregulated supply 24V ±10% current 50 mA. pressure switch<br />
status. Pressure media oil, water & non corrosive gases. Battery operation<br />
10h or mains operation via charger. Complete with a full range of pressure<br />
connection adaptors.<br />
SI PC6 Pressure Calibrator & Pump 1000 Bar<br />
SI,pC6-1000-NATA<br />
Range is 1,000bar. Nata calibrated Instrument. Measures Voltage 0~100mV<br />
(1µV resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) &<br />
current 0~50mA (1µA resoultion) @ 0.025% accuracy. Sources 0~10V<br />
(0.2mV resolution) & 0~50mA (1µA resolution) @ 0.025% accuracy.<br />
Voltage output regulated 10V ±0.1% current 30mA and unregulated supply<br />
24V ±10% current 50mA. pressure switch status. pressure media oil and<br />
water (unit can measure non corrosive gases but not pump them). Battery<br />
operation 10h or mains operation via charger. Complete with a full range of<br />
pressure connection adaptors.<br />
SI Pressure HTP1 Pressure Pump<br />
SI,HTP1 NZ<br />
Hand operated hydraulic pressure pump, capable of 700bar. Quick priming<br />
and pressure generation. High pressure/priming selector. Fine adjustment<br />
control. pressure release valve. Supplied with integral IANZ calibrated<br />
digital gauge. Uses paraffin oil as the working fluid.<br />
SI Pressure TP1-40 Pressure Pump<br />
SI,Tp1-40 NZ<br />
Fully portable hand operated dual source of pneumatic pressure and vacuum.<br />
Generates up to 40bar pressure or 96% vacuum. Adjustable stroke to<br />
provide over pressure protection. Supplied with thread adaptors. Reference<br />
gauge is required, see optional Fluke pressure modules FLU,700pxx.<br />
Druck DPI603 Pressure Calibrator 10Bar NATA Certified<br />
DRU,DpI603-10-NATA AU<br />
Displays in 24 different units. Interface ⅛”bsp. Accuracy 0.075%fs, includes<br />
pump for vacuum and pressure. pumps to 20bar pressure & -850mbar<br />
vacuum. Measurements can be made to 20bar positive pressure & -1bar<br />
vacuum. Unit has a 24V energising voltage. Monitors loop current to<br />
55mA dc @ ±0.075% reading & 0.005%fs. Monitors loop voltage to 50V @<br />
±0.15% of reading & 0.02%fs. Unit sealed to Ip65. battery life per charge<br />
is approx 40h (no 24V load).<br />
Druck DPI603 Pressure Calibrator 20Bar<br />
DRU,DpI603-20 AU/MY<br />
Accuracy 0.075%fs. pumps up to 20bar pressure & -850mbar vacuum.<br />
Measures up to 20bar pressure & -1bar vacuum. In-built 24V energising<br />
voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface<br />
⅛”bsp. battery operated.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Druck DPI603 Pressure Calibrator 20Bar NATA Certified<br />
DRU,DpI603-20NA AU<br />
Includes pump for vacuum and pressure can display in 24 different units.<br />
Interface ⅛”bsp. Accuracy 0.075%fs. pumps 20bar pressure & -850mbar<br />
vacuum. Measurements can be made to 20bar positive pressure & -1bar<br />
vacuum. Unit has a 24V energising voltage. Monitor loop current to<br />
±55mAdc @ ±0.075% reading & 0.005%fs. Monitor loop voltage to 50V @<br />
±0.15% of reading & .02%fs. Unit is sealed to Ip65. battery life per charge<br />
is approx 40h (no 24V load)<br />
Ambit Calibration Kit 20MPa<br />
AMb,CAL-20MpA AU<br />
20Mpa gauge with hydraulic hand pump, accuracy 0.5%fs.<br />
Druck DPI610HC 160Bar Pressure Calibrator<br />
DRU,DpI610-160 AU<br />
Hydraulic pressure calibrator including pump and current voltage standard.<br />
pressure range 160bar ±0.025%fs. Voltage input ±50Vdc, ±0.05% reading<br />
& ±0.004%fs. Current input ±55mA, ±0.05% reading & ±0.004%fs.<br />
Temperature 10~40OC, ±1 (ambient) switch open/closed. Voltage output<br />
10Vdc, ±0.1% or 24V ±5%. Current output 0~24mA, ±0.05% reading &<br />
±0.01%fs. Datalogger stores up to 10,000 values. mA ramp configurable.<br />
Pressure port G 1 / “(f). pump includes screw adjustment.<br />
><br />
8<br />
NEW Druck DPI610~20~NATA 20Bar Pressure Calibrator<br />
NATA Certification<br />
DRU,DpI610-20-NATA AU<br />
Pneumatic pressure calibrator including pump and current voltage standard.<br />
pressure range -1~20bar ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg,<br />
±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature<br />
-10~40°C ±1°C (ambient) switch open/closed. Voltage output 10Vdc ±0.1%<br />
or 24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger<br />
stores upto 10,000 values. mA ramp configurable. pressure port G ⅛f,<br />
includes flexible hose kit. pump includes screw adjustment.<br />
> NEW<br />
Druck DPI610~20IS Pressure Calibrator<br />
DRU,DpI610-20IS MY<br />
Ranges -1~20bar. Accuracy 0.025% fs all ranges. Integral combined<br />
pressure/vacuum pump. Dual readout: input & output. 4~20mA loop<br />
test: auto step and ramp. RS232 interface and fully documenting version.<br />
Remote pressure sensors. Intrinsically safe version.<br />
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 99
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
100<br />
induStrial calibratOrS<br />
Druck DPI610-2-NATA 2 Bar Pressure Calibrator<br />
DRU,DpI610-2-NATA AU<br />
Pneumatic pressure calibrator including pump and current voltage standard.<br />
pressure range -1~2bar, ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg,<br />
±0.004%fs. Current input ±55mA, ±0.05%rdg, ±0.004%fs. Temperature -<br />
10~40°C, ±1 (ambient) switch open/closed. Voltage output 10Vdc, ±0.1% or<br />
24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger stores<br />
up to 10,000 values. mA ramp configurable. pressure port G 1 / 8 ” (f), includes<br />
flexible hose kit. pump includes screw adjustment.<br />
Druck DPI610-400-NATA 400 Bar Pressure Calibrator<br />
DRU,DpI610-400-NATA AU<br />
DRU,DpI610-400 MY<br />
Hydraulic pressure calibrator including pump and current voltage standard.<br />
pressure range 0~400bar ±0.025%fs. Voltage input 50Vdc, ±0.05%rdg,<br />
±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature<br />
-10~40ºC ±1ºC (ambient) switch open/closed. Voltage output 10Vdc ±0.1%<br />
or 24V ±5%. Current output 0~24mA, ±0.05% rdg, ±0.01%fs. Data logger<br />
stores up to 10,000 values. mA ramp configurable. pressure port G 1 / 8 ” (f),<br />
includes flexible hose kit. pump includes screw adjustment.<br />
ultraSOnic bathS<br />
Soniclean 1000HT Ultrasonic Cleaning Bath<br />
SON,1000HT AU<br />
Tank size 495w x 295d x 150h mm includes heater and timer.<br />
> NEW<br />
Druck Loop Calibrator<br />
DRU,UpS-3 AU<br />
Measure and source 0~24mA, accuracy 0.01% of reading, dual mA and %<br />
readout, linear or flow. Step, span check, valve check, ramp. Measurement<br />
and continuity 60Vdc. HART compatible internal 235Ω loop resistor, menu<br />
selectable. Large graphic LCD.<br />
Ametek PPCE 700 Bar Pressure Calibrator<br />
AME,ppCE-NATA AU/MY<br />
High pressure calibrator with pump 700bar (10,000psi). Digital display with<br />
5 digit resolution. Accuracy over 70bar ±0.07. Accuracy below 70bar ±0.35.<br />
Current and voltage measurement ranges 4~20mA, 0~50mA & 0~30V.<br />
Ametek Hydralyte HL2700N Dead Weight Tester<br />
AME,HL2700N AU/MY<br />
Dual range interchangeable piston:-100~4,500kpa, 0.5kpa increments,<br />
500~22,500kpa, 1kpa increments. Accuracy 0.05% of reading. Includes<br />
special calculator for high accuracy pressure calculations and also<br />
conversion of units.<br />
Soniclean 2000HT Ultrasonic Cleaning Bath<br />
SON,2000HT AU<br />
Tank size 495w x 295d x 299h mm includes heater and timer.
NEW<br />
Angelantoni CH340 Environmental Temperature Chamber<br />
ACS,CH340C AU<br />
Temperature range -75~180ºC, humidity range from 10~98% RH in the<br />
range of 10~80ºC, dew point range 2~94ºC for continuous tests. Relative<br />
humidity accuracy ±1%~±3%. Capacity 336lt. Internal 600w x 800d x 700h<br />
mm. External dimensions 850w x 1725d x 1516h mm. Control by uPLC &<br />
graphical control panel on the door. Program temp & RH cycles and control<br />
all chamber functions and alarms. Entry port, door with inspection window,<br />
internal lighting, 1 shelf, RS232C interface. Electrical rated power 5.7kW,<br />
maximum used power 9kW. Voltage 400 +6%, -10%, 50Hz, 3ph. Noise<br />
63dbA , weight 750kg approximately including transit case.<br />
ACS CH106C Temperature & Humidity Environmental Chamber<br />
ACS,CH160C AU<br />
Temperature range -70~180ºC, humidity range from 20~95%RH in the range<br />
of 10~80ºC, dew point range 5~79ºC for continous tests. Realtive humidity<br />
accuracy ±1%~±3%. Useful capacity 178L, internal 560w x 564d x 560h<br />
mm. External dimensions 760w x 1115d x 1370h mm. Control by micro<br />
pLC and control panel placed on the door (4 lines alphanumeric display and<br />
keyboard). pLC programs Temp & RH cycles and to control all chamber<br />
functions and alarms. Entry port 80Ømm, door with 230 x 230mm window,<br />
internal lighting, 1 shelf, RS232C interface. Dissipation at -55ºC,100W.<br />
Electrical power 4.5kW (average 3.3kW). Voltage; 230V +6%, -10%, 50Hz,<br />
1ph. Noise 60dbA measured at 1m from the front in a non reverberating<br />
room. Weight; 390kg (excluding transit case).<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
envirOnmental teSt chamberS/OvenS<br />
Model Type Temperature°C Humidity %RH Size (litres)<br />
AES,LH-6<br />
ACS,CH160C Temperature & humidity chamber<br />
-70~180 20~95 178<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
-20~94 20~98 150<br />
ACS,CH340C -75-180 10-98 336<br />
LAb,OTWMD18<br />
30~200 66<br />
Laboratory oven<br />
MEM,ULE400 30~200 53<br />
TEN,TJR Temperature chamber -80~200 33.6<br />
ACS Trolley for CH160C Environmental Chamber<br />
ACS,<strong>TR</strong>OLLEY AU<br />
ACS Winkratos Software for CH160C Temperature & Humidity<br />
Chamber<br />
ACS,WINKRATOS AU<br />
Software for remote control of ACS,CH160C temperature and humidity<br />
chamber. Remote programming and control of chamber plus report<br />
generation. Includes Compaq Armada E500 pentium III 500MHz notebook<br />
computer & RS232C interface cable.<br />
Memmert ULE400 Laboratory Oven<br />
MEM,ULE400 AU<br />
Range 30~220OC. Capacity 53L, internal 400w x 400d x 330h mm. Two<br />
shelves. Electronic temperature control with max deviation of 0.8~4OC. Labec OTWMD18 Laboratory Oven<br />
LAb,OTWMD18 AU<br />
Fan forced laboratory oven, ambient to 200OC. Capacity 66L, digital<br />
temperature controller.<br />
Tenney TJR Environmental Temperature Chamber<br />
TEN,TJR AU<br />
Range -80~200OC. Workspace 400w x 280h x 300d mm. In transit case<br />
1350w x 720d x 1050h mm. Operates in case with lid off. Programmable<br />
controller 24 step display resolution 1OC. Heating rates 25~100OC, 15min<br />
or 25~200OC, 55min. Cooling rates 25~-40OC, 20min or 25~-80OC, 65min.<br />
Access port 50mmØ.<br />
AES LH-6 Temperature Humidity Chamber<br />
AES,LH-6 NZ<br />
Internal dimensions 610w x 510d x 480h mm. External dimensions 1170w x<br />
840d x 790h mm. Operating range temperature -20~94 O C, ±0.5 at sensor.<br />
Humidity 20~98%RH ±2% at sensor. Includes self contained humidity system,<br />
200 x 200mm window, access port, microprocessor controller and high/low safety<br />
shut down.<br />
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 101
TEMPERATURE & HUMIDITY MEASUREMENT<br />
102<br />
temperature/humidity/barOmetric recOrderS<br />
Kane-May KM1242 5 Channel Indicator & Recorder<br />
KM,KM1242 AU<br />
Five channel temperature indicator and recorder. Range -100~1300 O C,<br />
resolution 0.1. Uses type K thermocouples. Gives average, max and min<br />
for period recorded. Operates from NiCd batteries or ac adaptor.<br />
Hanna HI98704, 4 Channel Thermocouple Printer<br />
HAN,HI98704 AU<br />
Four channel thermocouple input temperature display and printer. Accepts<br />
all common thermocouple types including K & T.<br />
Haenni KRK Thermohygrograph<br />
HAE,KRK501 MY<br />
Temperature -10~50ºC. Humidity 0~100%. Accuracy, thermograph ±1%fs,<br />
hygrograph: ±4%fs.<br />
temperature meterS/ir thermOmeterS<br />
Model Type<br />
RAY,Mx4+ IR thermometer laser sighted<br />
IR thermometer laser sighted plus digital<br />
RAY,Mx6<br />
camera<br />
Infrared thermometer with humidity probe and<br />
TES,845<br />
thermocouple probe<br />
> NEW Fluke 576 Photo Temp Infrared Thermometer with<br />
Built-in Camera<br />
FLU,576 AU/MY<br />
Range -30~900ºC. Minimum measurement 19mmØ, laser class II, 3 point<br />
spot. Includes adjustable emissivity from 0.1~1 by 0.01. Target size 1/60 of<br />
distance. Max, min, dif and av displayed on backlit lcd with bar graph. Data<br />
output USb or 1mV/ºC, windows software and cable included. Accuracy<br />
±0.75% of reading or ±1ºC which ever is greater. Response time 250ms.<br />
Display resolution 0.1ºC. Continuous measure mode.<br />
Micromech MM-01 Thermohygrograph<br />
MIC,MM01 AU<br />
Recording ranges -10~50 O C & 0~100%RH. Specify 7d or 24h charts.<br />
Hobo Pressure Logger<br />
HOb,pRES AU<br />
Range 0.5~16psia. Safe operating temp range -39~75 O C. Size 46w x 148d<br />
x 15hmm & 255g. Stores 1,800 measurements, 42 preset intervals. Data<br />
can be exported to spreadsheet. Logs in meters, feet, mbar and Hg. Battery<br />
life 2y.<br />
Dickson PR500 Pressure Logger<br />
DIC,PR500 NZ<br />
Records pressure in water and gas lines. Compact size is perfect for tight<br />
locations. Water resistant stainless steel case for use for outdoor applications.<br />
pressure range is 0~500pSI, accuracy is ±1% of full scale. Stores 7936 data<br />
points. Programming and data recovery done by TechRentals.<br />
Temperature<br />
Range ºC<br />
Output Ratio<br />
Type<br />
K<br />
Type J, T, E, N,<br />
R, S<br />
ANA,AN2406 Precision RTD thermometer -20~200 Serial & analogue RTD RTD<br />
FLU,52-2 Digital thermometer IR cxommunication port Yes<br />
FLU,54<br />
Logging with IR interface<br />
FLU,54-2<br />
RS232<br />
FLU,54Flukeview<br />
Dual channel digital logging thermometer -250~1,767<br />
IR interface & software<br />
FLU,54-2Flukeview Logging with IR interface USb<br />
FLU,576<br />
Photo temperature Infrared thermometer with<br />
built in camera<br />
2 Ch<br />
-30~900 USb or 1mV/ºC 60:1 No<br />
FLU,80pK3 Type K surface probe Probe<br />
FLU,80TK Type K transducer Analog out<br />
HAR,1521-NATA precision thermometer NATA -200~420 RS232<br />
MIC,M90H IR thermometer, high temperature range 600~3,000<br />
MIC,M90Z IR thermometer, narrow field of view -50~1,000<br />
-30~900<br />
Analog out & RS232<br />
-35~950 USb 75:1 Yes<br />
> NEW<br />
Fluke 52-2 Digital Thermometer<br />
FLU,52-2 MY<br />
Relative time clock on MIN, MAx, and AVG provides a time reference<br />
events. Electronic Offset function allows compensation of thermocouple<br />
errors to maximize overall accuracy . Measures J, K, T, & E-types of t/c.<br />
Readout in ºC, ºF, or Kelvin (K). battery life: typical 1000h. battery door<br />
allows easy replacement without breaking the calibration seal. Large backlit<br />
dual display shows any combination of T1, T2, T1-T2 plus MIN, MAx, or<br />
AVG. Additional t/c type R, S, & N (a total of 7 types). Recall function allows<br />
logged data to be reviewed on the display. IR communication port allows<br />
data to be exported to optional FlukeView Forms® Temperature pC software<br />
for further analysis and graphing. Data Logs up to 500 points of data with<br />
user adjustable recording interval.<br />
Yes<br />
180:1 No<br />
60:1<br />
Analog & USb 60:1<br />
1 Ch<br />
Yes<br />
No
NEW Testo 845 IR Thermometer With Humidity Probe and<br />
T/C Probe<br />
TES,845 AU<br />
Range -35~950ºC with built in humidity probe, range 0~100%RH.<br />
Switchable distance ratio far field 75:1 16mm, distance 1200mm, close<br />
focus 1mm, distance 70mm. Laser class II, 4 point spot/cross far field, 2<br />
point/1point close focus. Includes adjustable emissivity from 0.1~1, max,<br />
min, displayed on backlit LCD . Data output USb windows software and<br />
cable included. Accuracy ±0.75% of reading 100~950ºC. Display resolution<br />
0.1ºC. Continuous measure mode. plug in T/C probe supplied.<br />
Fluke 54 Dual Input TC with Logging<br />
FLU,54 AU<br />
Digital thermometer with data logging. Takes most t/c inputs. Accuracy<br />
±0.05% +0.3OC. Logging 500 points with date and time stamp. Records<br />
min, max or avg. Logged data can be reviewed on meter or downloaded via<br />
IR port (see FLU,54FLUKEVIEW).<br />
Fluke 54-2 Dual Input TC<br />
FLU,54-2 AU<br />
D series 2, dual input digital thermometer with data logging. Takes J, K, T,<br />
E, R, S, N T C inputs. Accuracy ±0.05%+0.3OC. 500 point logging with date<br />
and time stamp. Records min, max or avg. Logged data can be reviewed<br />
on meter or downloaded via IR port (see FLU,54FLUKEVIEW : Fluke 54 with<br />
IR/RS232 cable & Flukeview software or FLU,54-2FLUKEVIEW : Fluke 54-2<br />
with IR/RS232 cable & Flukeview software).<br />
Fluke 54 Dual Input TC with Flukeview Logging Software<br />
FLU,54FLUKEVIEW AU<br />
Specification as above. Logged data can be reviewed on meter or<br />
downloaded via IR port using cable and Flukeview software included.<br />
Fluke 54-2 Dual Input TC with Flukeview Logging Software<br />
FLU,54-2FLUKEVIEW AU<br />
Series 2, dual input digital thermometer with data logging. Will take most TC<br />
inputs. Accuracy ±0.05% +0.3ºC. 500 point logging with date & time stamp.<br />
Also records min, max or avg. Logged data can be reviewed on meter<br />
or downloaded via IR port RS232 interface, (using cable and Flukeview<br />
software included).<br />
Hart 1521 NATA Precision Handheld Thermometer<br />
HAR,1521-NATA AU<br />
Accuracy 0.025ºC. Includes 5614 probe ¼”Ø x 12” long. Calibrated in the<br />
-183~500ºC range. probe operating range -200~420ºC (cable and transition<br />
to 150ºC max).<br />
Analogic Precision RTD Thermometer<br />
ANA,AN2406 NZ<br />
Range -20~200ºC accuracy is ±0.1, resolution is 0.01. Supplied with a<br />
calibrated probe of 150mm x 6mmØ. Serial and analogue outputs. AC or<br />
battery operation.<br />
CHY 505 Portable Digital Reference RTD Thermometer<br />
CHY,505 NZ<br />
portable digital reference rtd thermometer. Range is -25~250ºC, resolution<br />
is 0.1, accuracy including probe ±0.05% of reading 0.3ºC. Supplied with<br />
pT385 RTD probe (length 150mm x 3mmØ) and IANZ endorsed calibration<br />
certificate.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
temperature meterS/ir thermOmeterS<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Raytek MX4+ Infrared Thermometer<br />
RAY,Mx4+ AU/NZ<br />
Range -30~900 O C. Size of measurement target is indicated by lasers.<br />
Instrument includes Type K t/c for additional temperature measurement<br />
to set emissivity. Target size 1/60 of distance. built in emissivity table,<br />
audible/visible high low alarm. Max, min, dif and ave display. RS-232 and<br />
analog output, windows software and cable included. Accuracy ±1%, ±1 O C.<br />
Response time 250m/s. Display resolution 0.1 O C. Continuous measure<br />
mode.<br />
Raytek MX6 Photo Temp Infrared Thermometer, Built in Camera<br />
RAY,Mx6 AU/NZ<br />
Range -30~900ºC with built in digital camera. Min measurement 19mmØ,<br />
laser class II, 16 point circle spot. Includes adjustable emissivity from 0.1~1.0<br />
x 0.01. Target size 1/60 of distance. Max, min, dif and av display with backlit<br />
lcd with bar graph. Data output USb or 1mV/ºC, windows software and<br />
cable included. Accuracy ±0.75% of reading or ±1ºC which ever is greater.<br />
Response time 250m/s. Display resolution 0.1ºC. Continuous measure<br />
mode. Digital camera and flash built in.<br />
Micron M90H Infrared Thermometer<br />
MIC,M90H AU<br />
Range 600~3,000OC. Focusing 500mm to infinity. Field of view for<br />
measurement 1:180 ( 1 O O / ). Resolution 1 C. Accuracy 0.4% of reading.<br />
3<br />
Recorder output 1mV/ OC. RS232C interface. Battery operated.<br />
Mikron M90Z-B Infrared Thermometer<br />
MIC,M90Z AU<br />
Features through lens sighting and sharp focusing. Temperature displayed<br />
in view finder. Data hold, peak valley and average functions. Temperature<br />
range -50~1,000OC. Accuracy 1%, 1OC. Field of view for measurement<br />
1:180. Rechargeable NiCd batteries give 8h life.<br />
Fluke 80TK Thermocouple Module<br />
FLU,80TK AU<br />
Use with DVM’s and recorders. Accepts K thermocouples. Temperature<br />
range -50~1,000 O C. Output 1mV/ O C. Type 80Kp-1 probe included.<br />
TEMPERATUIRE & HUMIDITY MEASUREMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 103
TEMPERATURE & HUMIDITY MEASUREMENT<br />
104<br />
thermal imaging cameraS<br />
Marconi Argus2 Black & White Thermal Camera<br />
MAR,ARGUS2 AU<br />
Gives live thermal image, quick and clear image. Good for fast assessment.<br />
Applications include general industrial work, electrical work, surveillance<br />
work and termite inspection. Displays temperature in the centre of image.<br />
If the image needs to be recorded you can use the NOG,USbVIDEO or<br />
the Cannon MV400i and use the analog video in (The ARGUS2 video out<br />
is an NTSC signal). The accuracy of the temperature measurement is<br />
±2OC or ±2% and the range is 0~500OC ±2 or ±2%. Ambient temperature<br />
measurement is ±2OC or ±5%. Display indicates a temperature difference<br />
of 0.1OC. Uses the 0.8~14µm thermal range. Dust and water proof to Ip67.<br />
battery life is 120min per battery (4 supplied).<br />
ISI 525 Snapshot Thermal Camera<br />
ISI,IR777 AU/NZ<br />
Uncooled thermal imaging system with a 4” high resolution TFT LCD display<br />
which captures and stores an image to a pCMCIA card. A cursor on the<br />
display can be driven to any point on the image and a temperature at that<br />
point read out. Measurement range is 0~350OC. pAL video output. In-built<br />
pCMCIA card stores 72 images.<br />
External Battery Pack for ISI,IR777 Thermal Imaging Camera<br />
ISI,bATTpACK-ExT AU<br />
Optional sealed lead acid battery pack for ISI,IR777 Thermal Imaging<br />
Camera. battery capacity 10Ah, includes carry case for battery with shoulder<br />
strap, smartcharger and special connector with 2m of connection cable.<br />
> NEW<br />
Flir InfraCAM thermal Imaging Camera<br />
FLI,INFRACAM AU<br />
Simple to use battery operated real time thermal imaging camera. In-built<br />
3.5” colour LCD, detector resolution 120 x 120. Ranges, spectral 7.5~13µm,<br />
temperature -10~350ºC, accuracy ±2 or ±2% of reading. Imaging frame rate<br />
9Hz, video output via USb interface, stores 50 images. Down load to pC via<br />
USb. Operating range -15~50ºC. Supplied with Quickview s/w and digital<br />
camera. Fixed spot on LCD, maximum 3 spots via software.<br />
Flir Systems E45 ThermaCam Thermal Imaging Camera<br />
FLI,E45 AU<br />
In-built 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral<br />
7.5~13µm, temperature -20~250 O C, accuracy ±2 or ±2% of reading.<br />
Imaging frame rate 50Hz, video output standard RCA composite video,<br />
stores 200 images, image run or freeze. Download to pC via USb. Operating<br />
range -15~45 O C. Supplied with download software and Panasonic digital<br />
camera. Single moveable spot for temperature measurement. Built in tripod<br />
mounting, 1/4”-20.
SAT S160 Real Time Thermal Imaging camera<br />
SAT,S160 AU/NZ<br />
With 2.5” colour LCD, detector resolution 160 x 120. Ranges, spectral<br />
8~14µm, temperature -20~250 O C ±2 or ±2%. Imaging frame rate 50Hz,<br />
video output pAL, image storage 500 pictures, image run or freeze. Image<br />
download to pC via USb. Ambient operating range -15~50 O C. Supplied with<br />
download software and panasonic DMC-FZZA digital camera.<br />
Model Type Features<br />
pAN,pM880 Industrial Moisture Analyser Intrinsically safe<br />
pAN,MMS35 Moisture meter for air & nat gas Moisture content under pressure<br />
PRO,SM* Concrete & timber moisture meter Two pin inspection mode & RF mode<br />
PRO,CMIII* Concrete moisture meter Gel conductivity & standard surface humidity test<br />
*See Concrete Testing Equipment<br />
> NEW<br />
GE Panametrics PM880 Industrial Moisture Analyser<br />
pAN,pM880 AU<br />
Intrinsically safe moisture analyser for compressed air systems, noncorrosive<br />
gases & hydrocarbons such as natural gas (IS certification to<br />
ATEx and CSA). Displays dew point, moisture concentration, pressure &<br />
temperature. Dew point calibrated measurement range -80~20°C with data<br />
to -110°C. pressure range 7~69bar limited by sensor, gauge and safetyvalve<br />
(operating range from 5µHg). Temperature range -30~70°C. Gas flow<br />
operating range from static to 10,000 cm/sec velocity. Supplied with compact<br />
sample system with gauge, safety-valve, sampling valves and fittings (¼”<br />
Swagelok). Data logging of up to 100K moisture points, with infrared port<br />
and software for download. battery powered only (15-24h operation) with<br />
second battery and charger (note charger is not IS).<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
thermal imaging cameraS<br />
SAT Tripod Fitting Adaptor For SAT S160 Camera<br />
SAT,<strong>TR</strong>IpOD-FIT AU<br />
Tripod fixture clamps around the SAT,S160 thermal imaging camera and<br />
then allows this camera to be mounted on a tripod.<br />
humidity & mOiSture meterS<br />
Panametrics MMS35 Air/Natgas Moisture Analyser<br />
pAN,MMS35 AU<br />
Intrinsically safe for compressed air systems and hydrocarbons such as<br />
natural gas. Displays dew point & ppm moisture by volume. Pressure<br />
set as a constant. Data logging with RS232 port for download. Operating<br />
temperature range -110~70 O C. pressure range 5µHg~5,000psig. Accuracy<br />
60~-60 O C ±2, -66~-110 O C ±3. Repeatability: 60~-60 O C ±0.5, -66~-110 O C<br />
±1. Response time
SECURITY EQUIPMENT<br />
106<br />
Security equipment<br />
Detec DH50 Hand-held Metal Detector<br />
DET,DH-50 AU<br />
Simple to operate, no adjustment needed. Audible alarm.<br />
Detec DH50 Hand-held Metal Detector Kit of 4<br />
DET,DH-50-KIT4 AU<br />
Kit of 4 x hand held security metal detector. Simple to operate - no adjustment<br />
needed. Audible alarm.<br />
Garrett CS5000 Walk Through Metal Detector<br />
GAR,CS5000 AU<br />
Detects all metals. Requires assembly on-site & set-up. Adjustable<br />
sensitivity.<br />
Garrett Superscanner Hand-held Metal Detector<br />
GAR,SUpERSCANN AU<br />
For security applications.<br />
Swise Surveillance Digital Camera<br />
SWI,COLOR AU<br />
Captures up to 700 images. Includes motion detector, only takes images of<br />
changes. Can be connected to a modem to dial and transmit the images.<br />
Contact input which activates dialing so it could be connected to a DataTaker<br />
for dial out alarms. Includes software and cable to download the images<br />
to a PC directly or via a modem. Will not operate until powered. When<br />
finished, will not operate after power down. System can be configured and<br />
downloaded by <strong>TR</strong> Services (please request quotations). System draws<br />
120mA @ 12V, operates for 3d on 10Ahr 6V batteries, or for 6d on 8 alkaline<br />
D cells or 9d on 2 lantern batteries.<br />
AVE Serial to Video Converter Including Video Mixer<br />
AVE,VSIpLUS AU<br />
Mixes serial data (text) with video signal, so that a picture includes this text.<br />
Use with a GpS (eg GA,E<strong>TR</strong>Ex) to add a location reference to a video or<br />
used with cash register RS232 output to record transactions on a security<br />
camera picture.<br />
Elbex 1-Camera VCR Surveillance System<br />
ELb,CCTV2 AU<br />
Single camera time lapse video recorder. Uses pin hole camera and 24h time<br />
lapse VHS VCR. VCR can accept an alarm input from a motion detector, etc<br />
and this will provide a time stamp and trigger a period of real time recording.<br />
Camera lens 8.5mm giving 70O field of view. Video monitor included.<br />
Poptron CCD RF Camera and Receiver IR Lighting<br />
pOp,RF-CCD AU<br />
Video surveillance camera with radio frequency link. Transmits video &<br />
audio from a camera 30m~100m depending upon conditions (900~930MHz<br />
carrier). Standard video & audio output. Infrared illuminator included - range<br />
1.5m.<br />
Optalign RF Transmitter Detector System<br />
OpT,bUG AU<br />
Radio transmission detector system useful for ‘bug’ detection and nearby<br />
transmission interception. Comprises 3 principal units R10 FM interceptor<br />
which auto tunes to a near field transmitter - range 120m typical for 5W<br />
VHF/UHF. In-built speaker and deviation indicator. Frequency range<br />
30MHz~2GHz. R20 AM interceptor with headphone output. Frequency<br />
range 500kHz~2.5GHz. Signal strength bar graph. Scout 40 frequency<br />
counter for off air frequency indication of near field transmissions. In-built<br />
logging permits a walk through surveillance of an area. Accessory antennas<br />
are included to optimise reception. An optional pC package permits long<br />
term surveillance - see separate model.<br />
Optalign Optalog Scanning Software<br />
OpT,OpTOLOG AU<br />
pC interface and software for OpT,bUG Scout 40 frequency counter.<br />
Pacom 8 mm Colour Camera, Auto Iris, 6~15mm Lens<br />
CAM,COL-AUTO AU<br />
Colour surveillance camera 8mm CCD auto Iris 6~15mm lens.<br />
4 Camera Surveillance Digital Stand-Alone Record System<br />
CAM,DVMR-4C AU<br />
4 day/night colour cameras with stand-alone digital video multiplex recorder,<br />
complete system with 15” colour LCD screen, 20m connection cables, power<br />
supplies and video to USb coverter for down loading of data to pC.
did yOu knOW….<br />
We have Over<br />
10,000 itemS Of<br />
SpecialiSed<br />
technical<br />
equipment in Our<br />
inventOry, SO<br />
We’re bOund tO<br />
have a SOlutiOn tO<br />
virtually any teSt<br />
and meaSurement<br />
prOblem.<br />
tO See Our full<br />
range viSit Our<br />
WebSiteS and<br />
dOn’t fOrget<br />
tO regiSter fOr<br />
neW prOduct<br />
releaSeS tOO.<br />
www.techrentals.com.au<br />
www.techrentals.co.nz<br />
www.techrentals.com.my<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
metal detectOrS<br />
Pulse Technology AQ-1B Underwater Metal Detector<br />
pUL,AQ-1b AU<br />
Suitable for above ground use also. Hand-held, battery operated, complete<br />
with high sensitivity 15” search coil, compact 8” coil, and small ferrite probe.<br />
Supplied with a bone conduction phone for underwater use and headphones<br />
for above ground use. Complete with charger.<br />
Minelab SD2000 Gold Prospecting Metal Detector<br />
MIN,SD2000 AU<br />
Designed primarily for gold prospecting. Kit includes 2 search heads, battery<br />
and 240V and in-car battery chargers. Incorporates multi-period sensing<br />
(mps), allowing the unit to operate in highly mineralized soils (it will detect<br />
nuggets at 2~4 times the depth of a typical metal detector). battery life<br />
16h.<br />
Cscope CS550 General Purpose Metal Detector<br />
CSC,CS550 AU<br />
Simple to use and light weight. Ideal for locating rings, etc. Works well in<br />
locating metal underground services.<br />
Excaliber 1000 Under Water Metal Detector<br />
ExA,1000 AU<br />
MIN,Ex-1000 MY<br />
Search coil 10”. Use effectively in or out of the water. Features 2 operating<br />
modes all metal and discriminate. In discriminate mode, ignores most<br />
ferrous objects and still detects the valuable non-ferrous objects such as<br />
gold and silver. Rechargeable battery pack separated from the electronics<br />
cylinder allows easy access for recharging.<br />
retail traffic flOW cOunterS<br />
Traffic Pro People Counter Event Logger<br />
<strong>TR</strong>A,RETAILpACK AU<br />
Counts the number of people passing a particular point. Used to check the<br />
success of in-store promotions, counting people entering sections of a store,<br />
etc. The unit operates from internal batteries and will store one years worth<br />
of data at a 1h sample rate.<br />
SECURITY EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 107
did yOu knOW….<br />
tr cOrpOratiOn<br />
haS 30 lOcatiOnS<br />
acrOSS the aSia<br />
pacific regiOn,<br />
SO itS never been<br />
eaSier tO rent<br />
yOur teSt and<br />
meaSurement<br />
needS frOm uS.<br />
viSit Our WebSiteS<br />
fOr cOntact<br />
detailS.<br />
www.techrentals.com.au<br />
www.techrentals.co.nz<br />
www.techrentals.com.my
ENVIRONMENTAL
FLOW METERS<br />
110<br />
flOW meterS - liquid<br />
Model Type Features Max Flow Temp °C Pipe Ø mm Major Application<br />
pAN,pT868<br />
pAN,pT878<br />
Ultrasonic<br />
Transit time<br />
Non-contact<br />
Data logging<br />
RS232C<br />
4~20mA<br />
Data Logging<br />
IR interface<br />
Large LCD<br />
Global FP101 Digital Water Velocity Meter<br />
GLO,Fp101 AU<br />
portable flow probe - current meter for water velocity measurements in<br />
streams, channels and partially filled pipes. propeller sensor in 50mmØ<br />
housing, fitted to telescopic handle [1.8m] with gauging marks to 900mm<br />
depth. Digital LCD flowmeter display for instantaneous liquid velocity and<br />
average, maximum, stopwatch or clock. Minimum depth about 50mm.<br />
Range 0.1~4.5m/s ±0.05.<br />
Panametrics PT868 Ultrasonic Flowmeter<br />
pAN,pT868 AU/NZ<br />
portable non-contact liquid flowmeter using transit-time principle. Includes<br />
transducers for pipe diameters 50mm~2m and temperatures -20~150 O C<br />
[additional transducers available] with clamping fixture. Flow velocity range<br />
0.03~12.2m/s. Accuracy typically 1%. Data logging capacity. Analog [current<br />
loop] and RS232C outputs, and analog inputs compatible with temperature<br />
transmitters for energy-flow calculations. Totalised flow and trend analysis.<br />
Rechargeable NiCd operation for 8~10h or operation from ac mains or<br />
external dc 10~28V supply.<br />
~12m/s -20~150 50~2,000<br />
Liquids, Energy flow<br />
Low gas/solids content<br />
pipes (clamp-on)<br />
Note: NATA versions available<br />
pAN,C-Lp-40NM<br />
-40~120 12~50 Small diameter pipes<br />
pAN,C-pT-10Hb<br />
Transducer set,<br />
pT868/878<br />
-20~210 50~2,000 Wide temperature range<br />
pAN,OKS -200~400 80~600 Very wide temperature range<br />
pAN,2CHRT-1-1 Temperature sensors,<br />
-20~130<br />
pAN,2CHRT-1-2 pT868/878<br />
-20~260<br />
pAN,SOFTWARE<br />
Software PT868 &<br />
pAN,MMS35<br />
Ultrasonic<br />
Dual frequency<br />
pOL,HYDRA-Sx30<br />
Doppler<br />
Data logging 10m/s -40~122 12~5,000<br />
Non-contact<br />
RS232C, 4~20 mA<br />
UNI,6526b-21<br />
UNI,6526b-21LCD<br />
HYS,OSSb1<br />
Ultrasonic<br />
Doppler<br />
propeller flow counter with<br />
field-computer<br />
GLO,FP101 propeller flow counter<br />
Log rate 5s –1 week<br />
Flow/Depth/Temp<br />
Log rate 5s –1 week<br />
Flow/Depth/Temp<br />
LCD display<br />
Stainless fan<br />
Adjustable depth<br />
storage & download<br />
Telescopic handle<br />
Velocity averaging<br />
Digital counter<br />
~5m/s -0~60<br />
5m/s<br />
4.5m/s<br />
5cm min<br />
depth<br />
Clamp-on<br />
Storage, Recall, Download<br />
Liquids, Slurries<br />
High gas/solids content<br />
Pipes<br />
Liquids, Slurries<br />
Open Channel<br />
Logging System<br />
Water Current Measurements<br />
Hydrology<br />
Rivers & streams<br />
Irrigation channels<br />
Panametrics Software for PAN,PT868 & PAN,MMS35<br />
pAN,SOFTWARE AU<br />
Software for pAN,pT868 flowmeter and pAN,MMS35 moisture analyser.<br />
Allows storage, recall and download of instrument setup routines. Versions<br />
available to match instrument firmware revisions.<br />
Panametrics PT868 Flowmeter NATA Certification<br />
pAN,pT868-NATA AU<br />
Specification as for pT868 above but NATA certification.<br />
Panametrics 12~50mm Transducers<br />
pAN,C-Lp-40NM AU/MY<br />
Transducer pair for pAN,pT868/878 transit-time flowmeter to suit pipe<br />
12~50mmØ. Complete with CF-Lp-50M mounting bracket. Temperature<br />
range -40~120 O C.<br />
Panametrics -20~210OC Transducers<br />
pAN,C-pT-10Hb AU<br />
High temperature transducer pair for pAN,pT868/878 transit-time flowmeter.<br />
Operates on pipe sizes 50mm~2mØ. Working temperature range -<br />
20~210 O C.<br />
Panametrics -200~400OC Transducers<br />
pAN,OKS AU<br />
Very high temperature, wide range transducer pair for pAN,pT868/878 transittime<br />
flowmeter. Temperature range -200~400 O C, for pipe 80mm~600mmØ.<br />
Uses special clamp system supplied. Appropriate protection and safehandling<br />
equipment is required for fitting and operation at very high or low<br />
temperatures.
Panametrics PT878 Ultrasonic Flowmeter<br />
pAN,pT878 AU/MY<br />
portable non-contact liquid flowmeter using transit-time principle. Includes<br />
transducers for pipe 50mm~2mØ & temperatures -20~150 O C (various<br />
alternative transducers available) with clamping fixture. Flow velocity range<br />
0.03~12.2m/s. Accuracy typically 1%. Data logging for over 10K data<br />
points. Analog inputs compatible with temperature transmitters for energyflow<br />
calculations. Outputs analog 4~20mA, digital (pulse or frequency) and<br />
printer/computer (Infrared port). Large LCD display for velocity, volumetric<br />
and energy flow rate, totalised flow and trend data in alphanumeric and<br />
graphical formats. Rechargeable NiMH batteries and ac power supply/<br />
charger.<br />
GE Panametrics PT878 Flowmeter with NATA Certification<br />
pAN,pT878-NATA AU<br />
Specification as above but with NATA certification.<br />
Polysonics Hydra SX30 Dual Frequency Doppler Liquid<br />
Flowmeter<br />
pOL,HYDRA-Sx30 AU<br />
Ultrasonic non-contact flowmeter. Velocity range 0.06~10m/s, accuracy<br />
±1%. pipe size range 12mm~5mØ. Data logging for 90,000 points, with pC<br />
software and interface cable for download via RS232C interface. Transducer<br />
temperature range; -40~122 O C. Analog output 4~20mA. battery operated,<br />
12h continuous use [8h recharge].<br />
Hydrological Services Universal Current Meter OSS-B1<br />
HYS,OSSb1 AU<br />
Water current meter for measurement of flow velocity in rivers, streams,<br />
channels and open water. Robust streamlined stainless body fitted with high<br />
precision 100mmØ fan [flow range 0.025~5m/s]. Set of stainless wading rods<br />
for depths to 3m. Rechargeable “Hydromate” ruggedised field computer with<br />
Ip65 case. Storage of fan calibration formulae for direct readout of volumeflow.<br />
Touch screen entry for set up, input, storage and download. Supplied<br />
with PC download software and cable.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
flOW meterS - liquid<br />
Panametrics 2-CH RTD TX for PT868/878 Energy Calcs<br />
pAN,2CHRT-1-1 AU<br />
Two channel 4~20mA RTD transmitter, range -20~130OC for energy rate<br />
and consumption measurements with pAN,pT868 or pAN,pT878 ultrasonic<br />
flowmeters. Provides supply and return temperatures for flowing liquid.<br />
panametrics cable and connector supplied. Fitted with pair of clamp-on<br />
Pt100 RTDs and cables. Powered from flowmeter.<br />
Panametrics 2-CH TX for PT868/878 Energy Calcs<br />
pAN,2CHRT-1-2 AU<br />
Two channel 4~20mA RTD transmitter, range -20~260OC for energy rate<br />
and consumption measurements with pAN,pT868 or pAN,pT878 ultrasonic<br />
flowmeters. Provides supply and return temperatures for flowing liquid.<br />
panametrics cable and connector supplied. Fitted with pair of clamp-on<br />
Pt100 RTDs and cables. Powered from flowmeter.<br />
Unidata Open Channel Liquid Flow Logger with LCD module<br />
UNI,6526b-21LCD AU<br />
Open channel flow logger with field LCD display module and 10 m cable<br />
(2m depth rating). Measurement and logging of flow-velocity (by Doppler),<br />
depth (by pressure) and temperature. programmable for flow-channel<br />
profile (laptop pC required for in-situ programming via RS232C). Operating<br />
temperature range 0~60 O C. Velocity 21~5,000 mm/sec +/-2%; depth<br />
0~2,000 mm +/-2%. Temperature: -17~60 O C +/-0.1; log-interval 5 sec~1<br />
week; memory 120k. programmable output to control devices such as water<br />
samplers. Detects and measures reverse flows. Charger and batteries<br />
supplied. Workhead dimensions 290 x 70 x 25mm.<br />
Unidata Open Channel Liquid Flow Logger<br />
UNI,6526b-21 AU<br />
Open channel flow logger, programmed in-situ for flow-channel profile<br />
(laptop pC required). Measurement of flow-velocity (by Doppler), depth (by<br />
pressure) and temperature. Includes 10m cable. Memory 120k, RS232<br />
interface. Log rate 5 sec~1 week. Operating temperature range 0~60 O C.<br />
Velocity 21~5,000mm/sec +/-2% (resolution 1); depth 0~2,000mm +/-2%<br />
(resolution 2). Temperature: -17~60 O C (resolution 0.1). Programmable<br />
output to control devices such as water samplers. Detects and measures<br />
reverse flows. Charger and batteries supplied. Workhead size 290 x 70 x<br />
25mm.<br />
FLOW METERS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 111
FLOW METERS<br />
112<br />
flOW meterS - gaS<br />
Model Type Features Max Flow<br />
SpI,VFM5000-50 Vortex<br />
4 ~ 20mA output<br />
Flow, Pressure, Temperature<br />
HOF,2000 & HOF,38 Turbine flowmeter Totalising recorder outputs<br />
SIE,S100-5<br />
KUR,2443-24<br />
pVL,CLIMA3<br />
TSI,4143-6<br />
TSI,4040-6<br />
Mass-flow thermal<br />
sensor<br />
Thermal mass-flow<br />
insertion meter<br />
Insertion<br />
micro-turbine<br />
Mass-flow thermal<br />
sensor<br />
Mass-flow thermal<br />
sensor<br />
“Dial-A-Gas” for 10 gases<br />
RS232C, Analog outputs<br />
Cold tap fittings, RS232C<br />
Logging, 4 ~ 20mA output<br />
Hot-tap rig<br />
RS232, Pressure transducer<br />
Temp measurement<br />
RS232C, Mains/battery<br />
Temp measurement<br />
RS232C, Mains/battery<br />
ClimaAir 3 Flow Meter for Compressed Air & Gases<br />
pVL,CLIMA3 AU<br />
Portable gas flowmeter for compressed air and other applications. Fitted<br />
with “Combisensor” insertion probe for simultaneous measurement of flow,<br />
pressure and temperature. Measuring ranges flow 0.06~40m/s, pressure<br />
to 15bar, temperature to -20~80ºC. Supplied with valve and adaptor-kit for<br />
hot-tapped pipes approx 25~150mm ID, and fitting-kit for pipes to 450mm.<br />
Flow computer functions include flow correction, volume-calculation, and<br />
data logging for about 15,000 values. With RS232 interface and cable, and<br />
software for data download. Rechargeable with AC adaptor.<br />
Sierra Series 100 Gas Mass-flowmeter 0~5l/min<br />
SIE,S100-5 AU<br />
Smart-Trak mass flowmeter. Digital display of mass flow rate for gases<br />
in the range 0~5l/min. Dial-A-Gas set up for direct readout of flow for 10<br />
different common gases without adjustment or recalibration. Analog and<br />
serial RS232 ports, with software and cable provided for connection to PC.<br />
Portable configuration with case, battery, ac power supply and flexible gas<br />
connection set.<br />
Portable Mass Flowmeter & Calibrator 0~300 SLPM<br />
TSI,4040-6 AU<br />
Thermal mass flowmeter or field calibrator for operation in the range<br />
0~300SLpM (standard litres/min). LCD display for flow, temperature and<br />
pressure . Suitable for flow measurements on clean air, or for calibration<br />
checks on personal sampling pumps. Accuracy ±2%/0.05SLpM [whichever<br />
is greater] for air or oxygen [±3%/0.10SLpM for nitrogen or air-mixtures].<br />
Operating pressure range 50-199kpa absolute [approx 95kpa gauge]. With<br />
HEpA filter, adaptor and tubing. RS232C/analog connector with cables<br />
supplied. AC adaptor or battery operation.<br />
Temp<br />
°C<br />
pipe Ø<br />
mm<br />
600m 3 /h Supplied DN50<br />
~200ACFM<br />
(50mm)<br />
Major<br />
Application<br />
Air under pressure<br />
Saturated steam<br />
38mm or 50mm turbine Gases<br />
5slpm ¼” (at meter) Low – flow gases<br />
12,000sfpm -40~200 50mm~ Gases<br />
40m/s -20~80<br />
0.01~20slpm<br />
0~50<br />
~150mm<br />
(450mm without hot-tap)<br />
In-line 9.5mm<br />
~300slpm In-line 22mm ISO<br />
Compressed air<br />
Clean air flow<br />
Use as calibrator<br />
Clean air flow<br />
Use as calibrator<br />
Portable Mass Flowmeter & Calibrator 0.01~20 SLPM<br />
TSI,4143-6 AU<br />
Thermal mass flowmeter or field calibrator for operation in the range<br />
0.01~20SLpM (standard litres/min). LCD display for flow, temperature and<br />
pressure . For flow measurements on clean air, or for calibration checks on<br />
personal sampling pumps. Accuracy ±2%/0.005SLpM [whichever is greater]<br />
for air or oxygen (±3%/0.010SLpM for nitrogen or air-mixtures). Operating<br />
pressure range 50-199kpa absolute [approx 95kpa gauge]. With HEpA filter,<br />
adaptors and tubing. RS232C/analog connector with cables supplied. AC<br />
adaptor or battery operation.<br />
Hoffer 2000 Gas Flow Meter Indicator<br />
HOF,2000 AU<br />
Flow indicator/totalizer for use with flow transducers. Digital display with<br />
recorder outputs 0~10V, 4~20mA. RS232C interface. Operates from ac<br />
mains. Display of metric units with optional conversion factor.<br />
Hoffer 38mm Gas Flow Turbine/Transducer<br />
HOF,38 AU<br />
38mm MS flared gas flow turbine/transducer for use with HOF,2000.<br />
Volumetric flow rate range 1.75~120 actual cfm - gas type, pressure and<br />
temperature correction may be used for mass flow units such as SCFM,<br />
kg/min or L/s. Supplied with 38mm Table E Flanges. Approach pipe length<br />
380mm, exit pipe length 190mm.<br />
Kurz 2443 Air Velocity Meter<br />
KUR,2443-24 AU<br />
portable air velocity meter and flow-computer. Velocity range 0~12,000sf/min<br />
(60m/s) at pressures to approx 10bar (probe rated to 20bar). Temperature<br />
range -40~200OC with compensation. User selected English or metric units<br />
for velocity or mass-flow. Thermal sensor probe 9.5mmØ & 330mm long<br />
with sensor-shield, with compression fitting and nylon ferrules for probe<br />
removal or position adjustment in tapped pipe. Suitable for use in ducts or<br />
pipes, min pipe 50Ømm. Calibrated for air, and suitable for use with other<br />
non-hazardous gases. Recording of up to 1,500 data sets with time and<br />
date. Two analog 4~20mA outputs, and RS232C serial port for configuration<br />
upload and data download. Rechargeable NiMH batteries.
Model Type<br />
SHO,CFM88-3<br />
TSI,8373<br />
TSI,8370<br />
TSI,8371<br />
TSI,8375<br />
AIR,EDM2500<br />
DRU,DpI705<br />
HAL,EMA150<br />
Balometer<br />
Accubalance modular air<br />
balancing tool<br />
Manometer (electronic)<br />
Air Velocity<br />
m/s<br />
0.13~41<br />
depending on<br />
probe<br />
~14<br />
~28<br />
Flow<br />
l/s<br />
12~944<br />
air flOW meaSurement/air quality<br />
Max<br />
Temp O C<br />
15~1,000 60<br />
11~1,000<br />
Pressure Functions Notes<br />
±3735Pa diff<br />
135 kpa abs<br />
125 Pa<br />
500 Pa<br />
2,500 Pa<br />
Logging<br />
Logging<br />
Recorder output<br />
0~20 kpa Analog output<br />
Hood<br />
Pitot<br />
Velocity Matrix<br />
SHO,ADM-860 ~50 0.025~14,700pa With Velgrid<br />
TSI,8704 1.25~78.5 -1245~3735pa<br />
AIR,DM2<br />
DPM,TT370S 1.2~100<br />
Manometer (digital)<br />
DPM,TT570CL 10~100 10~100<br />
TSI,8704<br />
Logging<br />
RS232C<br />
±200kpa Recorder output<br />
pressure:<br />
199.9Pa<br />
1999Pa<br />
7.0kpa<br />
pressure:<br />
99.9Pa<br />
999Pa<br />
7.0kpa<br />
Logging<br />
RS232C<br />
Without Pitot tube<br />
Extendable Pitot Tube<br />
1.27~78.5 -1245~3735pa<br />
TSI,8705<br />
Differential Micromanometer<br />
Pitot Tube<br />
TSI,8710 10~100 3735Pa<br />
TSI,8345<br />
0.15~30<br />
TSI,8355 Anemometer (hot wire) 0.15~50<br />
TSI,8384 0.1~50 60<br />
TSI,8324<br />
AIR,AV2<br />
AIR,AV6<br />
SCH,MINI-2<br />
Anemometer<br />
(vane, 100 mm)<br />
Anemometer<br />
(vane, 22 mm)<br />
0.25~30<br />
0.3~40<br />
TES,450 Anemometer<br />
(vane, 16mm)<br />
0.4~40 130<br />
TES,445 0.4~60 140<br />
AIR,UA6<br />
0~50<br />
AIR,UA30<br />
Anemometer (ultrasonic)<br />
0~30<br />
93<br />
80<br />
Logging<br />
Max, Min &<br />
Sweep<br />
70 Analog output<br />
Logging<br />
RS232C<br />
HOB,PRES Pressure logger 75 500~110,000pa<br />
KUR,2443-24 Air Velocity Meter 0~60 200 10*/20bar<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
70<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Results<br />
averaging<br />
Min/Max display<br />
Logging<br />
Ma, Min & Mean<br />
Logging<br />
RS232C<br />
Logging<br />
Static Tip<br />
Pitot Tube<br />
Velocity Matrix<br />
Articulated telescopic extension<br />
NATA version available<br />
Telescopic probe<br />
Micro-vane probe<br />
Low flow turbulence<br />
Low flow turbulence<br />
Reads to 0.001 m/s<br />
Flow – computer<br />
With pipe-fittings*<br />
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 113
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
114<br />
air flOW meaSurement/air quality<br />
Model Type<br />
TSI,8520<br />
Particle measurement<br />
Temp<br />
O C<br />
RH%<br />
CO<br />
ppm<br />
CO 2<br />
ppm<br />
NO<br />
ppm<br />
Dust & Aerosol Notes<br />
0.001~100mg/m 3<br />
0.1~10µ<br />
AbA,301 0.3~5µ<br />
TSI,8525<br />
TSI,8386A<br />
Ultra fine particle<br />
measurement<br />
Multifunction air quality<br />
meter<br />
TSI,8551 Indoor air quality monitor<br />
TSI,8554<br />
(multi-function)<br />
YES,205-5<br />
Multifunction air quality<br />
logger<br />
TES,645-1<br />
TES,645-2<br />
60 5~95<br />
50 5~95 500 5,000<br />
0.01 ~ 5x10 5 particles/cm 3<br />
0.02~1µ<br />
Logging<br />
TSI,8520-1 Outdoor enclosure<br />
Logging<br />
Logging, Wet bulb<br />
Dew point, Differential pressure<br />
Logging<br />
RS232C/Software<br />
50 5~95 200 10,000 300 Logging<br />
Humidity & dewpoint meter 120 2~98 Robust stainless probe<br />
CAS,MICROTHERM Area heat stress monitor * *<br />
Portable Smoke Generating Machine<br />
CSS,COLT4 AU<br />
portable smoke generator with variable smoke emission rate. Suitable for<br />
air flow visualisation, HVAC ductwork leak-testing, fire training and general<br />
work. pump-free operation with smoke fluid supplied from consumable<br />
aerosol cans or refillable containers [pump supplied for pressurisation].<br />
Manual or continuous operation and off-power facility. Maximum output 31<br />
cubic meters/min at 1.5m visibility. Operation for 18min from one can at<br />
maximum capacity.<br />
Airflow EDM2500 Electronic Manometer 0~2500 Pa<br />
AIR,EDM2500 AU/NZ<br />
pressure ranges 125, 500 & 2,500pa. Air velocity measurement using pitotstatic<br />
tube with ranges 14 & 28m/s. Supplied complete with pitot static tube,<br />
balancing valve, and tubing. Fitted with 1mA fsd recorder output. battery<br />
operated.<br />
Airflow DM2 Medium Pressure Manometer<br />
AIR,DM2 NZ<br />
Handheld medium pressure digital manometer. Suitable for positive,<br />
negative and differential pressure measuements. Displays readings in mBar,<br />
kpa & psi. Ranges are ±2,000mbar, 200kpa & 29.99psi. Resolution is 1 or<br />
0.1mbar & 0.1 or 0.01kpa. Accuracy on all ranges is 0.5% of reading. Serial<br />
interface for uploading stored results. Maximum stored readings during<br />
logging is 700. Analogue output of ±1V at 0.5mV per mbar.<br />
WBGT index, RH + Dewpoint<br />
*Air temp to 60º, Wet temp to 40º<br />
Globe temp to 120º<br />
> NEW<br />
TSI 8710 DP-CALC Differential Micro-Manometer<br />
TSI,8710 AU<br />
Micro-manometer for static or differential pressure, velocity, volumetric<br />
flow, atmospheric pressure and temperature. With statistical analysis,<br />
density correction, K factor and automatic actual/standard flow calculation.<br />
Differential pressure range ±3735pa. Velocity display to 78m/s (range<br />
depends on probe). Supplied with static tip, Pitot tube, velocity matrix and<br />
temperature probe. Datalogging (1,000 point) with RS232C interface and<br />
software. Rechargeable cells or AC adaptor.<br />
> NEW<br />
TSI 8705 DP-CALC Differential Micro-Manometer<br />
TSI,8705 AU<br />
Differential micro-manometer measuring differential pressure, velocity,<br />
average, volumetric flow, maximum and minimum. With static pressure<br />
calculations, density correction and K factor. pressure range -1245~3735pa.<br />
Velocity range 1.27~78.5m/s. Supplied with 200~980mm telescopic pitot<br />
tube. Datalogging (1000 point) with RS232C interface and software. Battery<br />
powered.
TSI 8704 DPCALC Micro Manometer<br />
TSI,8704 AU<br />
Measures differential pressure, velocity, average, volumetric flow, max & min.<br />
With static pressure calculations, density correction and K factor. Pressure<br />
range -1245~3735pa. Velocity range 1.25~78.5m/s. Extendable pitot tube<br />
20~980mm. Datalogging 500 point with RS232C interface and software.<br />
DPM TT370S Digital Manometer<br />
DPM,TT370S NZ<br />
Digital micromanometer with an extendable pitot tube kit. Dp ranges are<br />
199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s. Dp<br />
accuracy is 1% of reading +2 counts. Recorder output of 1mV per count.<br />
DPM TT570CL Digital Manometer NATA Certification<br />
DpM,TT570CL-NATA NZ<br />
Digital micromanometer with an extendable pitot tube kit. Dp ranges are<br />
199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s.<br />
Dp accuracy is 1% of reading +2 counts. built-in data logger holds 1,400<br />
readings.<br />
Druck DP1705 Manometer 0~20 kPa<br />
DRU,DpI705 AU<br />
Handheld digital manometer range 0~20kpa, accuracy 0.2 %. Displays all<br />
common engineering units.<br />
Shortridge ADM-860 Electronic Manometer<br />
SHO,ADM-860 AU/MY<br />
Electronic micro manometer for air balance and similar applications.<br />
Measures differential pressure, air velocity and temperature. Differential<br />
pressure range 0.0025~1,500mm wg. Velocity range 7.5~3,000m/min<br />
(750m/min with velgrid). Memory 100 point with sum and average.<br />
Accessories include pitot tube and 16 point velgrid for face velocity work<br />
including exhaust hoods, clean room outlets, and large filters or coils.<br />
Airflow 36 Pitot Tube<br />
AIR,pITOT-36 AU<br />
pitot tube (36”) for use with manometers and micro manometers.<br />
Kurz 2443 Air Velocity Meter<br />
KUR,2443-24 AU<br />
portable air velocity meter and flow-computer. Working velocity range<br />
0~12,000 sf/m (60m/s) at pressures to approx 10bar (probe rated to 20bar).<br />
Temperature range -40~200OC with compensation. Selectable English<br />
or metric units for velocity or mass-flow. Thermal sensor probe 9.5mmØ<br />
x 330mm long with sensor-shield. Compression fitting and nylon ferrules<br />
for probe removal or position adjustment in tapped pipe. Suitable for use<br />
in ducts or pipes, min pipe 50mmØ approx. Calibrated for air and suitable<br />
for use with other non-hazardous gases. Recording of up to 1,500 data sets<br />
with time and date. Two analog 4~20mA outputs, and RS232C serial port for<br />
configuration upload and data download. Rechargeable NiMH batteries.<br />
TSI 8370 Accubalance Balometer<br />
TSI,8370 MY<br />
balometer including 5-hood kit and hard case. Flow range 15~1,000 litres/<br />
sec (50 to 3,500m3/hr) accuracy +/-5%, reading +/- 2.4 l/s (8.5m3/hr).<br />
Operating temp range 0-60OC. Weight (610 x 610mm hood) 3.4 kg hood<br />
provided 610 x610mm (standard), 610 x 1220mm, 305 x 1220mm, 305 x<br />
1525mm and 915 x 915mm.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
air flOW meaSurement/air quality<br />
TSI 8371 Accubalance Balometer<br />
TSI,8371 NZ<br />
Airflow hood 610 x 610mm. Measures air volume flowing through registers,<br />
diffusers, and grilles. Range is 15~1,000l/s, accuracy is ±5%. Temperature<br />
range is 0~60ºC. Sample and hold function displays reading of one sample.<br />
Automatic conversion between actual and standard flows when user initially<br />
inputs temperature and barometric pressure, variable time constant modes<br />
available for a steady display when measuring fluctuating flows, K factor<br />
function enables flexibility for measuring a variety of diffusers, back-lit display<br />
is easy to read in poor lighting conditions.<br />
TSI 8373 Balometer With Logging<br />
TSI,8373 AU<br />
Flow range 15~1,000L/s (50~3,500m3 /hr); accuracy ±5% [to ±2.4L/s].<br />
Operating temperature range 0~60OC. Includes 5 hood kit & hard case.<br />
Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,<br />
305 x 1,525mm & 915 x 915mm.<br />
TSI 8375 Accubalance Modular Air Balancing<br />
TSI,8375 (NZ)<br />
Balometer with detachable micromanometer for air balancing applications.<br />
610 x 610mm air capture hood for measurements in the range 42~4,250m3/<br />
h with automatic compensation for barometric pressure and air temperature,<br />
450mm pitot probe (range 0.13~41m/s), 16-point velocity matrix probe<br />
(0.13~13m/s) and static pressure probes (differential pressure range<br />
±3,735pa with safe limit 37kpa, absolute pressure range 47~135kpa).<br />
Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit<br />
LCD display for single or statistical readings with min, max and average of<br />
up to 1,000 values of each measured parameter. Manual result storage or<br />
automatic data logging up to 1,000 time/date stamped readings. RS232 port<br />
for data transfer to pC or serial printer, with cable and “LogDat” download<br />
software. Rechargeable with approx 12h operation, or ac adaptor.<br />
Shortridge CFM88-3 Electronic Balometer<br />
SHO,CFM88-3 AU<br />
Measures supply and exhaust flow in cfm and l/sec. Ranges 25~2500cfm<br />
supply and 25~1500cfm exhaust. Compensated for air density and back<br />
pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.<br />
Airflow AV2 100mmØ Anemometer with Volume display<br />
AIR,AV2 AU/NZ<br />
Vane anemometer with 900mm (35”) telescopic probe extension. Velocity<br />
measurement range 0.25~30m/s (50~6,000ft/min). Averaging mode<br />
available. Volume display based on duct or other area. Head operating<br />
range -10~70OC (lower limit of -30CC for short periods). Output 0~1V.<br />
Airflow AV2 100mmØ Anemometer NATA Certification<br />
AIR,AV2-NATA AU<br />
Specification as above but with NATA certification.<br />
Airflow AV6 100mmØ Anemometer with Volume<br />
AIR,AV6 NZ<br />
Vane anemometer 100mmØ with articulating extension handle. Measures<br />
velocity, volume flow and temperature. Vane head operating range is -<br />
10~70ºC, -30 possible for short periods. Accuracy is ±1% of reading +1<br />
digit. Resolution is 0.01 m/sec. Velocity range is 0.25~30m/s. RS-232C<br />
interface for data logging & real time data retrieval. Stores up to 99 readings<br />
of velocity & temperature. Analogue output of 0~1v.<br />
Schilknecht Mini Air 2 Vane Anemometer<br />
SCH,MINI-2 AU<br />
probe 22mmØ. Range 0.3~40m/s. Min, max & time averaging functions<br />
with 0~1V analog output.<br />
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 115
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
116<br />
air flOW meaSurement/air quality<br />
> NEW<br />
Testo 445 Vane Anemometer with 16mm vane<br />
TES,445 AU<br />
Micro-vane probe. Simultaneous digital display of air velocity and<br />
temperature, with continuous-update, max, min & mean functions. Volumeflow<br />
option with entry of duct dimensions .Telescope mounted metal probe,<br />
vane 16mmØ. Operating range 0.4~60 m/sec, accuracy ±0.2m/s, ±1%mv<br />
up to 40m/sec. Temperature range -30~140ºC for short-term measurements.<br />
Selectable site-locations, and 3,000 point internal memory for manual saving<br />
or automatic data logging. Battery powered.<br />
Testo 450 Vane Anemometer with 16mm Vane<br />
TES,450 AU<br />
Anemometer with micro-vane probe. Digital display of air velocity and<br />
temperature. Telescope mounted metal probe, diameter 16mm. Operating<br />
range 0.4~40m/s ±0.2 and to 60m/s ±unspec. Temperature range -<br />
30~140 O C for short-term measurements. battery powered.<br />
TSI 8345 Hot Wire Anemometer<br />
TSI,8345 AU<br />
Thermal anemometer range 0.15~30m/s; accuracy ±3%; volumetric<br />
flow display; averaging capability up to 255 readings. Probe operating<br />
temperature range -17.8~93.3 O C. probe 98mm long x 6mmØ at tip. Digital<br />
display. RS232C printer interface. Battery or mains operation.<br />
TSI 8355 Hot Wire Anemometer<br />
TSI,8355 MY<br />
Range 0.15~50m/s. probe will operate over a temp range of -17.8~93.3ºC.<br />
Digital display with averaging capability o up to 255 reading. Temperature<br />
measurement range -17.8~+93.3 C RS 232 printer interface. battery & AC<br />
operation.<br />
TSI 8384 Hot Wire Anemometer<br />
TSI,8384 NZ<br />
Handheld hot wire anemometer. Velocity range is 0.1~50m/sec, accuracy<br />
is ±3% of reading or ±0.015m/s whichever is greater. Resolution is 0.01<br />
m/s. probe temperature range is -10~60ºC and 0~80%RH. Stores 1,394<br />
samples of velocity, volumetric flow-rate and temperature with time and date<br />
stamping. Data can uploaded to a pC or printed. Supplied with 10mmØ x<br />
1m telescopic probe.<br />
> NEW TSI 8324 VelociCalc 100mm Vane Anemometer with<br />
Volume Display<br />
TSI,8324 AU<br />
Vane anemometer with 100mm head, supplied with handle and 900 mm<br />
articulated telescopic extension. Velocity measurement range 0.25~30 m/<br />
s ±1%; temperature measurement range 0~80ºC ±0.5 ºC. Volume display<br />
range 0~4.36x106m3/h with input for circular or rectangular duct dimensions.<br />
Variable time-constant; sample statistics average, max and min; and “sweep”<br />
mode for extended continuous sampling. Internal memory for single point<br />
measurements or time-based data logging, for up to 2849 samples and 1000<br />
test IDs, with serial interface, cable and software for data download. Direct<br />
data acquisition [polling] from PC terminal modes. Battery powered with<br />
auto-power-off, and optional AC adaptor.<br />
TSI 8386A VelociCalc Air Conditioning Efficiency Meter<br />
TSI,8386A AU<br />
portable efficiency measurement system for HVAC and related work, with<br />
hot wire anemometer, static and differential pressure, temperature and<br />
humidity measurement with heat flow efficiency calculation. Velocity (hot<br />
wire) 0~50m/s, accuracy ±3.0%. Temperature -10~60OC, accuracy ±0.3.<br />
Wet bulb temperature 5~60OC. Relative humidity 0~95%RH, accuracy ±3%.<br />
Dewpoint -15~49OC. Static/differential pressure -1,245~3,735pa, accuracy<br />
±1%. probe length 100cm, tip diameter 7mm, base diameter 10mm.<br />
Includes data logging and printing. Battery operated.<br />
Airflow UA30 High Resolution Ultrasonic Anemometer 0~30m/s<br />
AIR,UA30 AU/NZ<br />
precision anemometer range 0~30m/s, accuracy better than 1% of reading,<br />
resolution 0.001m/s, non-directional. Temperature range 0~70OC, accuracy<br />
1OC, resolution 0.1OC. Flow turbulence range 0~99%. Capable of measuring<br />
very low air velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up<br />
to 99 readings of velocity, temperature and turbulence, intervals 1s~99min.<br />
RS232C interface. Operates for 20h on alkaline batteries.<br />
Airflow Ultrasonic Anemometer 0~50m/s<br />
AIR,UA6 AU<br />
Range 0~50m/s, accuracy better than 1% of reading, resolution 0.01m/s,<br />
non-directional. Temperature range 0~70 O C, accuracy 1 O C, resolution<br />
0.1 O C. Flow turbulence range 0~99%. Capable of measuring very low air<br />
velocities. Includes articulating telescopic rod 0.4~1.1m. Logs up to 99<br />
readings of velocity, temperature & turbulence, intervals 5s~99min. RS232C<br />
interface. Operates for 20h on alkaline batteries.
NEW<br />
Testo 635-2 Humidity, Temperature & Dewpoint Meter<br />
TES,635-2 AU<br />
portable humidity meter fitted with robust stainless probe with sintered filtercap<br />
for general or duct measurements to 120ºC, and fast-action K-type<br />
surface temperature probe. Displays relative humidity, absolute humidity,<br />
dew point, degree of humidity, enthalpy, temperature, and differential<br />
temperature (dewpoint~surface). Operating range 2~98%RH (±2%). Air<br />
temperature -20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1).<br />
Internal memory for 10,000 values with USb interface, cable and software<br />
for download and presentation. Battery operated.<br />
Testo 635 Humidity & Dewpoint Meter<br />
TES,635 NZ/MY<br />
Temperature, humidity and dew point meter. Probe temperature range is<br />
-20~70ºC. Humidity range is 0~100%RH resolution: 0.1%, accuracy is ±2%.<br />
Dew point range is -50~40ºC.<br />
Testo 645 Humidity & Dewpoint Meter<br />
TES,645-1 AU<br />
portable humidity meter fitted with robust stainless probe for ambient work or<br />
duct measurements to 120OC. Displays relative humidity, absolute humidity,<br />
dew point, degree of humidity, enthalpy and temperature. Operating range<br />
2~98%RH [±2%], -20~120OC [±0.4/0.5]. battery operated.<br />
Abacus Hand-held Airborne Particle Counter<br />
AbA,301 AU<br />
Portable particle measuring system typically used in clean room applications.<br />
4 x fixed size channels 0.3, 0.5, 1.0 & 5.0micron. Count data automatically<br />
stored in a 500 sample memory which can be downloaded to a PC.<br />
Selectable sample time. Includes zero count filter for checking backgrounds.<br />
When used with included software will check clean rooms to ISO 14644 and<br />
BS5295 requirements. Battery operated.<br />
Vaisala WAA151 Wind Speed/Direction Transducer<br />
VAI,WAA151 AU<br />
Range 0.4~75m/s. Current output with selectable ranges including 4~20mA<br />
& 0~20mA. Requires indicator module such as DE,DT600 datalogger for<br />
indication of windspeed and direction.<br />
TSI 8551 Indoor Air Quality Monitor with Logging<br />
TSI,8551 AU<br />
Measures temperature, humidity, CO & CO concentrations. Humidity<br />
2<br />
5~95%RH, CO 0~500ppm, CO 0~5,000 ppm. Internal logging up to 63,000<br />
2<br />
data points; interval adjustable 1s~1h; RS232C interface and software<br />
included. Battery or mains operation.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
air flOW meaSurement/air quality<br />
TSI Q-Trak plus Indoor Air Quality Monitor with Logging<br />
TSI,8554 AU/NZ<br />
Indoor air quality (IAQ) monitor for temperature and humidity measurements,<br />
CO and CO 2 concentrations. Humidity range 0~95%, temperature range<br />
0~50 O C. Electrochemical cell for CO 0~500ppm. NDIR cell for CO 2<br />
0~5000ppm. Data logging for 48,671 data points with interval adjustable<br />
1s~1h. Fitted with RS232 interface, and software included for download,<br />
storage and reporting. Battery or mains operation with ac adaptor.<br />
YES 205-5 Indoor Air Quality Monitor with Logging<br />
YES,205-5 AU<br />
5 channels for temperature, humidity, CO2, CO & NO. Temperature range<br />
0~50OC, resolution 0.1, accuracy ±0.5. Humidity 5~95 %RH, accuracy<br />
±2%. CO2 0~10,000 ppm, resolution 0.5ppm. CO 0~200 ppm, resolution<br />
0.5ppm. NO 0~300 ppm, resolution 0.5ppm. Logging of CO and NO allows<br />
checking of indoor air for contamination by vehicle emissions from nearby<br />
carparks, loading docks etc. Includes interface and software. Mains/battery<br />
operation.<br />
Casella Microtherm WBGT Area Heat Stress Monitor<br />
CAS,MICROTHERM AU<br />
portable area heat stress WbGT monitor with real-time graphical display.<br />
Measures heat stress potential [WbGT index] according to ISO7243. pRTD<br />
sensors with internal calibration-reference for wet-bulb, dry-bulb and globe<br />
temperatures. Large LCD display for numerical or graphical indication of<br />
temperatures and processed values for WbGT [indoor/outdoor plus TWA],<br />
relative humidity and dewpoint. Simple keypad/menu setup. Data logging<br />
for up to 32 separate runs and 49,100 records, with interval 30s~1h. RS232C<br />
port with included PC software for download and reporting or realtime<br />
display. Low water-level warning, and settable audible/visible WbGT alarm.<br />
Handheld, free-standing or tripod-mount. battery operated.<br />
TSI 8520 DustTrak Airborne Particle Monitor<br />
TSI,8520 AU/NZ<br />
Portable aerosol monitor. Laser photometer with 90O scattering detection,<br />
Range: 0.001~100mg/m3 [Calibrated for A1 test dust, ISO 121203-1],<br />
resolution: 1% of reading or 0.001; particle size range: 0.1~10µm. Internal<br />
pump flow rate 1.4~2.4L/min (1.7 nominal). Data logging 30,000 data points<br />
(21d @ 1min), log interval: 1s~1h. RS232C interface and software included.<br />
Battery operated.<br />
TSI 8520-1 Environmental Enclosure for DustTrak<br />
TSI,8520-1 AU<br />
Weatherproof outdoor housing for TSI,8520 aerosol monitor. Rugged case<br />
with tripod mount, fitted with sample inlet and water trap. Includes extendedlife<br />
battery pack and charger/adaptor.<br />
TSI 8525 P-Trak Ultrafine Particle Counter<br />
TSI,8525 AU<br />
Range 0.01~5 x 105 particles/cm3 . particle size range 0.02 to greater than<br />
1micron. Includes PC software and cable. Suitable for detection of ultrafine<br />
particles associated with pollutants. Battery powered [8h operation using<br />
alkaline batteries].<br />
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 117
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
118<br />
air cOnditiOning balancing inStrumentS<br />
> NEW<br />
Testo 560-2 Electronic Manifold for Refrigeration Testing<br />
TES,560-2 AU<br />
Three-way valve bank, for commissioning, maintenance and repair<br />
of refrigeration systems. Stainless-steel block for use with common<br />
pressure media including CFC, FC, N, CO and ammonia; with stored<br />
2<br />
data (including saturation properties) on 36 refrigerants. Measurement of<br />
vacuum (0~200hpa), pressure (0-50bar), ambient [case] temperature for<br />
compensation (-10~50ºC) and system temperature (-100~400ºC instrument<br />
range; supplied with pipe-wrap probe 0~120ºC). Calculations for absolute/<br />
relative pressure, vacuum drying-efficiency, system cooling/heating capacity,<br />
leakage testing, superheating or sub-cooling values. Data storage, or<br />
interval-logging up to 100,000 readings, with serial interface and software<br />
for download, analysis and documentation. battery or AC adaptor powered.<br />
leakage detectOrS<br />
Haloteck Refrigerant Gas Leak Detector<br />
HAL,78000 AU<br />
For use by refrigeration engineers. Rapid response 0.2s, audio output,<br />
zero warm up time. Single control, battery operated, sensor tip insensitive<br />
to draughts. Sensitivity better than 3g/y R12, 25g/y R134A. Responds to<br />
halogenated hydrocarbons and many fire extinguishant gases, [also sulphur<br />
hexafluoride SF6]. Battery life 30h. Duty cycle continuous. Probe length<br />
240mm. Weight 280g.<br />
Bacarach Leakator 10 Combustible Gas Leak Detector<br />
bAC,LEAK10 AU<br />
Flexible probe with solid-state sensor for rapid area checks and pinpointing<br />
of large or small leaks. Sensitive to combustible vapours including common<br />
solvents, and gases including natural gas. Adjustable sensitivity with<br />
detection limit approximately 20ppm [methane]. Indication by ultra-bright<br />
LEDs and audible speaker. battery powered.<br />
Weather StatiOnS<br />
> NEW<br />
Environdata WeatherOne Wind Speed & Direction Logger<br />
ENV,DL20WSD AU<br />
Logging system for wind speed and direction. Tripod-mounted cross-arm<br />
stand with 3-cup windspeed sensor range 0-75m/s and independent vane<br />
direction sensor. Sealed dual-channel logger with memory for 35,000<br />
readings with time and date, fitted with backup battery, rechargeable sealed<br />
main battery and solar panel for in-field recharge. power supply for charging<br />
or operation from mains supply. “EasiAccess” software on CD for office or<br />
field connection via RS232C compatible computer (not included), for setup,<br />
download and real-time operation, with functions for tabular or graphical<br />
display.<br />
Tour & Anderson CBI Balancing Meter<br />
TA,CbI AU<br />
Digital pressure balancing instrument with LCD display. For cooling water<br />
valve balancing in air conditioning plants and similar applications. Firmware<br />
revision 3A. Includes facility for entry of Kv value to allow balancing of all<br />
hydronic valve types. Differential pressure range -0.5~20.5m water gauge<br />
at a total pressure of less than 200m. Resolution 0.001m. Flow resolution<br />
0.001L/s. battery operated.<br />
GasCheck 3000 Portable General-purpose Leak Detector<br />
ION,GASCHECK3000 AU<br />
Micro thermal-conductivity sensor for high-sensitivity detection of gases<br />
with a thermal conductivity different to that of air, including helium, carbon<br />
dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups.<br />
Direct reading of leak rate in ml/sec with audio and visible signals. Detection<br />
limit for helium 2E-5ml/s. battery powered.<br />
Environdata WeatherMaster 2000 Weather Station<br />
ENV,WM20 AU<br />
Measures air temperature -15~50 O C ±0.2, relative humidity 10~90%RH<br />
±5%, rainfall 0.2mm resolution. Wind speed starting threshold 1kph. Wind<br />
direction resolution 6 O ±3%. One spare input channel. Capable of storing<br />
up to 3mths of data. Includes RS232 interface and software for download.<br />
Mounts on star-picket. Solar-rechargeable batteries.
Hioki Lux HiTester Digital Illuminance Meter<br />
HIO,3423 AU/MY/NZ<br />
HIO,3423-NATA NZ<br />
Manual switching and autoranging. LCD display with 3½ digits (“1999”) for<br />
five measuring ranges to 20/200/2000lx in 1-count steps, 20,000lx in 10count<br />
steps and 200,000lx in 100-count steps with accuracy ±4%. Response<br />
time in autorange mode 5sec (2sec in manual range mode). Autozero, hold<br />
and backlight function with delay for taking readings in low light. Input for<br />
ac power adaptor, connecting-cable to allow separation of sensor unit and<br />
meter, and 200mVdc analog output with cable. Battery powered.<br />
Extech Digital Light Meter Nata<br />
ExT,407026 NZ<br />
NATA calibrated portable digital light meter. Ranges; 2,000, 20,000 & 50,000<br />
lux. Accuracy is ±4%. Displays in foot candles or lux for tungsten, daylight,<br />
fluorescent, sodium or mercury lamps. Data logging of measured values,<br />
Min/Max & Average, software and serial interface for uploading results.<br />
Minolta T-1 Lux Meter<br />
MIN,T-1 NZ<br />
Microprocessor controlled digital light meter. Measuring time can be<br />
adjusted for accurate readings of both continuous and flickering light<br />
sources. Illuminance deviation between sources can also be determined,<br />
or integrated illuminance over a period of time can be calculated. Range is<br />
0.01~99,900lx. Accuracy is ±2%.<br />
ILI 1400ABC Radiometer for UV Measurements<br />
ILI,1400AbC AU<br />
International Light model 1400 radiometer with backlit LCD display, autozero<br />
and autoranging. Continuous reading with hold function, or integrated “dose”<br />
measurement up to 24h. Smart detectors with storage of units and detectorcalibration<br />
data. Analogue recorder output. Mains adaptor or battery power.<br />
Supplied with three sensors: UV actinic hazard (UVC with b & A components<br />
matched to OSHA requirements), range 2.50e-7 to 2.50e-3 W/cm2 eff. UVb<br />
+ A (total “solar” radiation), range 1.16e-7 to 4.07e-1 W/cm2. UVb, range<br />
1.54e-6 to 1.54e-2 W/cm2.<br />
light & uv meaSurement<br />
Minolta CL-200 Chroma Meter for illuminance & Colour<br />
Measurement<br />
MIN,CL200 AU<br />
Konica Minolta model CL-200 portable colour meter. LCD display for<br />
illuminance, tristimulus values, chromaticity, correlated colour temperature<br />
and colour difference. Illuminance range 0.1~99,990lx ±2%. Colour accuracy<br />
±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface. battery powered,<br />
or AC adapter.<br />
Topcon BM-9 Luminance Meter<br />
TOp,bM-9-2 AU<br />
portable luminance meter with digital display. Field-of-view 5O , measurement<br />
acceptance angle 2O , with 10mm min spot diameter. Measuring distance<br />
0.35m to infinity. Silicon photodiode sensor with automatic or manual range<br />
selection. Measurement range 0.01~199,900cd/m2 ±4% of reading. built-in<br />
RS232C interface and analogue output. Battery powered.<br />
Topcon IM-2D Digital Luxmeter<br />
TOp,IM-2D AU<br />
Digital illuminance meter. Measuring range from 0.1~19,999lx. Accuracy<br />
±5%, +1 digit. Autoranging with silicon sensor. battery operated.<br />
Topcon IM-2D Lux Meter NATA Certification<br />
TOp,IM-2D-NATA AU<br />
Digital illuminance meter with NATA certification. Measuring range from<br />
0.1~19,999lx. Accuracy 5%, ±1 digit. Autoranging with silicon sensor.<br />
Battery operated.<br />
Topcon IM-5 Lux Meter NATA Certification<br />
TOp,IM-5-NATA AU<br />
Digital wide-range illuminance meter with NATA certification. Measuring<br />
range 0.01~199,000lx. Accuracy ±2% +1 digit. Autoranging with silicon<br />
sensor. Analog output and RS232 interface. battery operated.<br />
SOund Signal analySiS<br />
HP35660A 100kHz Dual Channel Spectrum Analyser<br />
Hp,35660A AU<br />
401 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal<br />
sources: fixed sine, random noise, chirp. built-in disk drive. HpIb plotter interface. bandwidth is 102.4kHz for single channel measurements and 51.2kHz<br />
for dual channel measurements.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
OCCUPATIONAL HEALTH & SAFETY<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 119
OCCUPATIONAL HEALTH & SAFETY<br />
120<br />
nOiSe & SOund analySerS<br />
Model Description Type/Class Features RS232C Major Applications<br />
bK,4443 Noise dosemeter (2) built-in set up routines, 53,000 values<br />
bK,2237A<br />
RIO,NL-04 2<br />
ac & dc outputs<br />
RIO,NL-11Fp Octave filter,printer<br />
Sound level meter<br />
RIO,NL14 1/1 octave filter, ac & dc outputs Yes<br />
> NEW<br />
ARL EL-316 Environmental Noise Logger Type 1<br />
ARL,EL-316 AU<br />
Environmental noise logger with display for field-reading of summary results.<br />
portable, self-contained and weatherproof. Type 1 performance, continuous<br />
90db dynamic range, fast response, frequency weightings A and C. Monitors<br />
environmental noise continuously for up to 3 weeks, calculates and stores<br />
over 7500 sets of Ln indices. PC required to set up system and download<br />
data using software supplied. Set up also possible from front-panel.<br />
40 data records, ac output<br />
bK,2237A-NATA NATA certificate, ac output<br />
RIO,NL05 Recorder outputs<br />
> NEW<br />
Ivie IE-35 Type 1 Audio Analysis Systems<br />
IVI,IE35-2p AU<br />
Audio Analyser with Dell Axim x51v pDA. Fitted with half-inch free-field<br />
Type 1 microphone and pre-amplifier. Functions include SpL (sound level),<br />
Real-time analysis, “seat-to-seat” variation for audio setup, reverberation<br />
measurement, “strip-chart” recording on display, voltage and oscilloscope<br />
displays and signal generation. Supplied with field-calibrator, microphone<br />
extension cable, spare battery and software for data-download to pC. SpL<br />
facilities include time and frequency weightings - fast, slow, peak or impulse<br />
and A, C or Flat. FFT based Real Time Analysis includes 1/1, 1/3, or 1/6<br />
octave bands with a maximum resolution of about 1/24 octave. Additional<br />
functions include spectrum subtraction, averaging, Noise Critera or Reduction<br />
contours and reverberation-decay to ISO-20 and ISO-30. Signal-generation<br />
includes sine, square, triangle and white or pink noise.<br />
Yes<br />
OH&S<br />
OH&S<br />
General<br />
QUE,2400 ac & dc outputs General<br />
bK,2239A-NATA<br />
NATA certificate, ac output Yes<br />
RIO,NL14-NATA 1/1, 1/3 octave filter, NATA certificate<br />
RIO,NL31 1<br />
1/1, 1/3 octave filter<br />
RIO,NL-32RTA-NATA<br />
bK,2238E-NATA<br />
NATA certificate, Data logging<br />
Realtime frequency analysis<br />
(1/1, 1/3 octave), “Flashcard”<br />
Enhanced sound level meter firmware<br />
Data logging, Frequency analysis<br />
NATA certificate<br />
Yes<br />
OH&S<br />
General<br />
OH&S<br />
General<br />
Analysis<br />
BK,7815 Software n/a Compatible with bK4443, 2239A, 2238E-NATA n/a Advanced applications<br />
ARL,EL-215<br />
ARL,EL-315<br />
ARL,EL-316<br />
bK,2238NMT-KIT<br />
IVI,IE35-2p<br />
Environmental noise<br />
logger<br />
Audio Analysis<br />
System<br />
2<br />
1<br />
1<br />
2,048 data sets, Weatherproof<br />
7,500 data sets, Display<br />
Weatherproof<br />
7,500 data sets, Display<br />
Weatherproof<br />
25MB memory, Weatherproof<br />
With sound level meter<br />
Includes pDA, real time analysis, FFT, signal<br />
generation, reverb, “seat-to-seat”, pC download<br />
Yes Long term outdoor logging<br />
General Analysis<br />
Engineering, Audiovisual
B&K Noise Monitoring Terminal with model 2238F SLM<br />
bK,2238NMT-KIT AU<br />
Noise logging system with B&K model 2238F Class 1 Sound Level Meter<br />
equipped with internal software for Basic SLM and Logging. Portable,<br />
wheeled weatherproof case. Standard SLM operation for fast, slow and<br />
impulse time weighings and A, C or linear frequency weightings RMS. Linear<br />
or C frequency weightings for peak detection. Internal memory 2Mb total<br />
for logging up to 12 parameters including auxiliary signals. Fitted with serial<br />
RS232 interface, and provided with bKlink software for download of logged<br />
data to pC. Supplied with field calibrator, charger and 12V, 18Ah battery, for<br />
operation for up to 14d logging at 15min intervals.<br />
B&K 4443 Noise Dose Meter with Logging<br />
bK,4443 AU/NZ<br />
Fitted with remote microphone, for OH&S surveys. Logging of 1 or 2<br />
parameters from a range of 6, with variable interval. 4 built-in and 3 userdefined<br />
setup routines, 5 selectable statistical levels Lx. Storage of up to<br />
53,000 values over 16 measurement periods, and download [or setup] via<br />
PC using software provided. Supplied complete with field calibrator. Battery<br />
powered.<br />
B&K 2237A Type 2 Integrating Sound Level Meter<br />
bK,2237A AU<br />
Measures RMS and peak simultaneously. Linearly weighted analogue output<br />
for sound recording, 0~0.5V ac (rms). Measurement range 30~140db.<br />
Time weightings fast, slow & impulse. Independent frequency weightings<br />
A [for RMS readings SpL, MaxL, MinL, Leq, Inst] and C [for peak readings<br />
peak and Maxp]. Real time clock for time and date stamp. Records 40<br />
measurements for download to PC. Calibrator included. Battery operated.<br />
Quest 2400 Type 2 Sound Sound Level Meter<br />
QUE,2400 NZ<br />
Type 2 sound level meter with LCD display for sound pressure level (SPL) or<br />
maximum level (MAx). Frequency weightings A & C, time weightings Fast<br />
and Slow. Ranges 30~140dbA and 40~140dbC with overload indication. AC<br />
& dc outputs. Battery powered.<br />
Rion NL-04 Sound Level Meter<br />
RIO,NL-04 MY<br />
Meets IEC type 2. Five measurement functions: Lp(SpL), Leq, LAE, Lmax &<br />
Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. built-in<br />
RS232C interface for computer communication. 70dB dynamic range (digital<br />
display), 27~130db (A) measuring range. Wide range of time settings for<br />
Leq, LAE, Lmax & Lx;10s,1,5,10, 15, 30min,1, 8, 24h & manual time setting<br />
(up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display, 0.1db<br />
resolution, updated every second, plus 60dB analog display display 1dB<br />
resolution showing the instantaneous value. Memory battery back-up. AC &<br />
DC signal o/p for level expanding system by optional filters, memory card &<br />
others.<br />
Rion NL-05 Type 2 Sound Level Meter<br />
RIO,NL-05 AU<br />
Sound level meter to IEC 651/1979 & IEC 804/1985 type 2 requirements.<br />
Measures Lp, Lmax, Leq, Lae. Response types A, C, and flat. Fast and<br />
slow time weightings. Complete with calibrator. Internal memory and printout<br />
for Leq data (printer Cp-10 optional, also prints other parameters),<br />
RS232C interface. Recorder outputs 1V ac rms & 3.5V dc. Operates from<br />
batteries or ac adaptor.<br />
Rion NL-11FP Sound Level Meter System<br />
RIO,NL-11Fp MY<br />
Sound level meter complete with type Nx-01A octave filter, Cp-01 printer, &<br />
calibrator. Measures Leq, Le (Lax), Spl and time. Weighting filters A, C, and<br />
flat. Detector reads fast, slow, impulse, and peak (IEC 651). Measurement<br />
range 29 ~140 db rms.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
nOiSe & SOund analySerS<br />
B&K 2239A Type 1 Sound Level Meter NATA Certification<br />
bK,2239A-NATA AU<br />
Type 1 (class 1) integrating sound level meter with backlit LCD display, NATA<br />
certification. Simultaneous rms (A,C) & peak (C) detection with independent<br />
frequency weightings. Measuring range 30~140db. Time weightings fast,<br />
slow and impulse. parameters Leq, Maxp, MaxL, MinL, peak, SpL and<br />
Inst. Memory for 40 data records with realtime clock. Serial port for data<br />
download. Calibrator included. Operates with 4 x AA alkaline batteries.<br />
Rion NL14 Type 1 Sound Level Meter/Analyser<br />
RIO,NL14 AU/MY<br />
Precision integrating sound level meter meeting IEC type 1 standard. Fitted<br />
with Nx-04 single octave filter module range 31.5~16kHz in 10 bands.<br />
Supplied with NC73 calibrator. Weightings A, C, & flat. Measurement range<br />
with A weighting 25~130dbA. Measurement functions Lp (SpL), Lmax, Leq,<br />
Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold. Leq time<br />
from 10s~100h. In-built memory for up to 9,000 readings (Lp). Outputs 1V<br />
ac rms, 3.5V dc, RS232C interface. Continuous operation on batteries for<br />
12h. AC adaptor included.<br />
Rion NL14 SLM with 1/3 & 1/1 Octave Filter NATA Certification<br />
RIO,NL14-NATA AU<br />
Precision integrating sound level meter to IEC type 1 (class 1) specification,<br />
with NATA certification. Supplied with 1/1 & 1/3 octave filter module Nx-05,<br />
and calibrator NC73. Frequency range 20~12,500Hz with weightings A, C, &<br />
flat. Measurement range (A) 25~130db. Measurement functions Lp (SpL),<br />
Lmax, Leq, Lae, Lx. Time weightings fast, slow, impulse, 10ms, peak hold.<br />
Leq time from 10s~100h. In-built memory for up to 9,000 readings (Lp).<br />
Outputs 1V ac rms, 3.5V dc fs, RS232C interface. Alkaline batteries 12h<br />
operation or ac adaptor.<br />
Rion NL-31 Type 1 SLM with 1/1 & 1/3 Octave Filter<br />
RIO,NL31 NZ<br />
Complies with standards, IEC60651: 1979 Type 1, IEC60804: 1985 Type 1,<br />
IEC/CDV: 61672-1 Class 1. Simultaneous measurement of: sound level (Lp),<br />
equivalent continuous sound presure level (Leq), sound exposure level (LE),<br />
Maximum (Lmax) & Minimum (Lmin), percentile sound pressure level (LN),<br />
5 selectable settings. Measurement ranges are: A weighting: 28~138db,<br />
C weighting: 33~138db, flat: 38~138db, peak sound level: 141db. Time<br />
weightings are: fast, slow, impulse (impulse is selectable only for auxiliary<br />
processing functions). Ranges 100db dynamic, frequency 20~12,500Hz<br />
(including microphone). Timer function for automatic measurement over<br />
extended periods. Supplied with Nx-21SA 1/1 and 1/3 octave filter card.<br />
Rion NL-32 SLM with RTA & NATA Certification<br />
RIO,NL-32RTA-NATA AU<br />
RIO,NL-32 NZ<br />
Precision integrating sound level meter to IEC type 1 (class 1) specification,<br />
with NATA calibration. Fitted with internal Compact Flash Card reader<br />
and supplied with NC-74 field calibrator. Frequency range 20~20,000Hz<br />
with weightings A, C, and flat. Time weightings fast, slow and impulse.<br />
Measurement range (A) 28~138 db. broadband measurement functions<br />
Lp (SpL), Leq, Lmax/min, Lae, Lx, and selectable auxiliary functions with<br />
manual or auto storage [logging]. Measurement time (Leq) from 10 seconds<br />
to 200 hours. Inbuilt memory for up to 100 data sets, or to limit of fitted CF<br />
card using manual or auto storage. AC or dc outputs, RS232C interface and<br />
cable CC-93 for serial printer. Supplied with Nx-22RT card for real time 1/1<br />
and 1/3 octave analysis and display, for measurement functions Lp, Leq,<br />
LE, Lmax and display of Ap (all-pass) Ap(A) and 1/1 or 1/3 octave values<br />
as selected, with manual data storage only to Nx-22RT card. Download of<br />
card-data to pC requires flashcard reader. Alkaline batteries (24h operation)<br />
or AC adaptor.<br />
OCCUPATIONAL HEALTH & SAFETY<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 121
OCCUPATIONAL HEALTH & SAFETY<br />
122<br />
nOiSe & SOund analySerS<br />
B&K 2238E Type 1 Integrating SLM Enhanced Software &<br />
Logging<br />
bK,2238E-NATA AU<br />
Type 1 (class 1) Integrating sound level meter with additional functions<br />
including enhanced software, frequency analysis and data logging. Standard<br />
routines include functions for workplace measurements and general soundlevel<br />
checks; enhanced software (firmware) offers additional measurements<br />
and statistics for assessment of environmental noise problems; frequency<br />
analysis automates measurements in the 9 single octave bands and 29 1/3<br />
octave bands. Supplied with field calibrator. Compatible with BK,7815 Noise<br />
Explorer Environmental software for download, data analysis and display.<br />
B&K 7815 Environmental Software - Noise Explorer<br />
bK,7815 AU<br />
Software package for downloading and reporting of noise data measured<br />
with B&K meters. Compatible with sound level meters (2239, 2238) and<br />
noise dosemeters (4443). Offers data transfer, formatting of data for export,<br />
display and print in tabular or graphical form, file management and calculation<br />
of sound power or sound reduction index from intensity measurements.<br />
ARL EL-215 Environmental Noise Logger<br />
ARL,EL-215 AU<br />
Environmental noise logger. portable, self-contained and weatherproof.<br />
Monitors environmental noise continuously for up to 3 weeks. Calculates<br />
and stores 2048 sets of measured data. Continuous 90db dynamic range. A<br />
and C frequency weightings. Logs date, time, Leq, Lmax, L1, L5, L10, L50,<br />
L90, L95, L99, Lmin, temperature and battery (plus additional sensor). Scan<br />
interval 1 min~1 hour. RS232C interface. pC required for initial setup and<br />
results download.<br />
Oh&S & envirOnmental - general<br />
TSI SidePak SP730 Personal Sampling Pump<br />
TSI,Sp730 AU<br />
Personal sampling pump with internal digital flowmeter. Flow range<br />
to 3,000ml/min with internal low-flow bypass for precise control and<br />
measurement at low and high rates. Keypad programming with lockout<br />
option. Multimode operation for manual control and preset programs with<br />
intermittent sampling. Supplied with “Trakpro” data analysis software and<br />
USb interface. battery powered, 2,700mAH rechargable NiMH gives up to<br />
18.5h at 1L/min. Intrinsically safe.<br />
ARL EL-315 Environmental Noise Logger<br />
ARL,EL-315 AU/NZ/MY<br />
Environmental noise logger with display for field-reading of summary results.<br />
portable, self-contained and weatherproof. Continuous 90db dynamic range,<br />
frequency weightings A and C. Monitors environmental noise continuously<br />
for up to 3 weeks, calculates and stores over 7500 sets of Ln indices. pC<br />
required to set up system and download data using software supplied. Set<br />
up also possible from front-panel.<br />
Severn Model Tortus II Floor Slip Tester<br />
SEV,TORTUSII AU<br />
Floor friction tester. Measures and records the dynamic coefficient of<br />
friction. Applications in assessing floor safety, evaluating cleaning methods<br />
and maintenance procedures, accident investigation, etc. Meets the draft<br />
requirements of international, Australian and New Zealand standards.<br />
Lion Breath Alcohol Analyser<br />
LIO,SD-400p AU<br />
portable breath alcohol analyser with attached printer. Uses disposable<br />
mouthpieces. Approved by most law-enforcement agencies.
Model O 2 CO CO 2 NO NO 2 SO 2 H 2 S CH 4<br />
Efficiency<br />
Calculations<br />
TES,325-1 Y Y Y* Y<br />
gaS analySiS & mOnitOring<br />
Notes<br />
Industrial<br />
Domestic & light<br />
Oil & gas burners<br />
Temp °C<br />
Max<br />
Type<br />
600 Combustion efficiency<br />
TES,300M Y Y Y* Y Y<br />
Domestic<br />
1,200 Combustion efficiency<br />
TES,325M<br />
TES,335<br />
Y<br />
Y Y<br />
Y<br />
Y Y Y Y<br />
Industrial<br />
Industrial<br />
500<br />
1,000<br />
Flue Gas Analyser<br />
TES,350 Y Y Y* Y Y Y Y Domestic<br />
Industrial<br />
Power generation<br />
General<br />
1,200<br />
Combustion<br />
Flue Gas analysis<br />
TES,350xL Y Y Y Y Y Y Y 1,000 Combustion efficiency<br />
LAN,SERIES2-6 Y Y Y* Y Y Y Y Y<br />
NOV,1637-5CGA Y Y<br />
ISC,MDU420 Y<br />
*Calculated<br />
Model O 2<br />
ISC,ITx-STD<br />
ISC,TMx412<br />
ISC,MG140<br />
30%<br />
LEL<br />
(combustion)<br />
50 ppm (CH 4) to<br />
100% LEL<br />
100%<br />
C O<br />
ppm<br />
1,000 1,000<br />
Domestic, Industrial<br />
Power generation<br />
O 2 by Zirconia sensor<br />
CO 2 by NDIR<br />
Dual range<br />
NDIR methane analyser<br />
1,000<br />
Combustion<br />
Flue Gas analysis<br />
~600 Flue gas analysis<br />
~1,000<br />
Flue gas and general<br />
analysis<br />
Methane<br />
H 2 S Other Notes Applications<br />
Full confined space kit<br />
Logging & download<br />
Full confined space kit<br />
AIM,4650 25% 1,500 500 Logging<br />
NOV,1637-5<br />
from 1<br />
ppm<br />
CO 2 ~100 %<br />
ISC,MDU420 CH 4 ~100 %<br />
AER,500L portable Logging Ozone Monitor<br />
ppM,FORM400<br />
O 3<br />
0~0.500ppm<br />
Formaldehyde<br />
0.05~10.00 ppm<br />
Zirconia & NDIR sensors<br />
Wide range<br />
NDIR sensor<br />
Logging & download<br />
Mains or battery<br />
Logging & download<br />
Formaldehyde emissions<br />
from resins, furniture, textiles,<br />
etc<br />
Personal monitoring<br />
Confined space entry<br />
Personal monitoring<br />
General purpose<br />
Scientific<br />
Food packaging<br />
General purpose<br />
Landfill methane<br />
Indoor air quality<br />
“Sick building” syndrome<br />
LIO,SD-400p Alcohol Approved design Breath – alcohol<br />
RAE,MR200<br />
bAC,LEAK10<br />
ION,GASCHECK3000<br />
Detects, screens and measures VOC contaminants. Sensitive to<br />
benzene, Ammonia, Gasoline vapour and many more.<br />
portable leak detector for combustion gases. Detects methane<br />
to ~ 20 ppm<br />
portable leak detector using thermal conductivity.<br />
Wide range of gases including helium.<br />
ApT,ODA6000Cp Portable Gas Monitor<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Photoionisation detector<br />
Visual & audible leak<br />
indication<br />
Visual & audible signal<br />
Carbon Monoxide<br />
Nitrogen Dioxide<br />
Environmental & OH&S<br />
General<br />
Environmental & OH&S<br />
Heating, Ventilation & Aircon<br />
(“HVAC”)<br />
General purpose<br />
High sensitivity<br />
Car parks<br />
Loading Areas<br />
GAS ANALYSIS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 123
GAS ANALYSIS<br />
124<br />
gaS analySiS & mOnitOring<br />
> NEW<br />
Testo 335 Combustion Gas Analyser<br />
TES,335 AU<br />
portable industrial flue gas analyser. Determines temperature (to ~1000<br />
deg C), draught/pressure (±40hpa), oxygen (21%), carbon monoxide<br />
(10,000ppm) and nitric oxide NO (3000ppm) concentrations. Calculates<br />
carbon dioxide concentration, efficiency and flue gas loss. Thresholdprotection<br />
of sensors, with 5x autodilution of CO to 50,000ppm. Separate<br />
sensor-socket with mini-probe for ambient temperature, and connection<br />
points for compatible differential-pressure devices. built-in condensatetrap<br />
with warning and auto-switch-off. Internal memory [100 folders x 10<br />
locations x 200 datasets each] for storage of measurement-protocols and<br />
data for printout. Supplied as kit with 335mm probe, cone and shield-plate,<br />
cordless printer and power supply. Rechargeable or AC operation (alkaline<br />
batteries used by printer).<br />
> NEW<br />
Testo 325M Combustion Gas Analyser<br />
TES,325M AU<br />
Portable flue gas analyser for tuning, maintenance and service adjustments<br />
of oil and gas burners. Determines temperature (to ~500ºC), draught/<br />
pressure, oxygen (21%) and carbon monoxide (4000ppm) concentrations.<br />
Calculates carbon dioxide concentration and gross/net efficiency. Supplied<br />
as kit with probe, cordless printer and power supply for mains operation.<br />
Operation 230Vac (with power supply) or alkaline batteries (AA also required<br />
by printer).
Testo 325-1 Combustion Gas Analyser<br />
TES,325-1 AU<br />
Portable flue gas analyser for measurements and adjustments of oil and<br />
gas burners. Determines temperature (to 600 O C), draught/pressure, oxygen<br />
(21%) and carbon monoxide (2,000ppm) concentrations. Calculates CO 2<br />
concentration and gross/net efficiency. Supplied as kit with probe, cordless<br />
printer and power supply for mains operation. Operation 230V ac (with<br />
power supply) or alkaline batteries (AA, also required by printer).<br />
Testo 300M Combustion Gas Analyser<br />
TES,300M AU/NZ/MY<br />
Flue gas analyser for combustion efficiency measurement. Temperature<br />
range -40~1200 O C ±0.5 (100) with gas probe operation to<br />
1,000 O C max. Draught/pressure range 80mbar, ±0.03 . Gases measured: O 2<br />
0~21%, ±0.2%; CO 2 [calculated] 0~CO 2 max %vol ±0.2%; CO 0~8,000ppm,<br />
±20 (
GAS ANALYSIS<br />
126<br />
gaS analySiS & mOnitOring<br />
ISC MG140 4-gas Personal Monitor for CH4 4 , O 2 , CO & H 2 S<br />
ISC,MG140 AU<br />
Four gas personal monitor for combustible gases (% LEL), oxygen (% O2),<br />
carbon monoxide (ppm CO) and hydrogen sulphide (ppm H2S). International<br />
approvals UL & CSA - class 1, groups A, b, C & D. Audible [90db] and visual<br />
alarms. Supplied with case and belt-loop, calibration cup and battery charger.<br />
Run time 8-10h on full charge.<br />
ISC Gas Monitor for CH 4 , O 2 , CO & H 2 S<br />
ISC,TMx412 AU/NZ<br />
Four gas monitor complete with confined space entry kit. Detects 4 gases<br />
flammable (CH 4 ), oxygen (O 2 ), carbon monoxide (CO) and hydrogen sulphide<br />
(H 2 S). Measures % LEL flammable, % O 2, ppm CO & H 2 S. Intrinsically safe<br />
EEx ia T4 rated (Australian Approved). Confined space entry kit includes<br />
sampling pump, tubing, filters and carry case. Designed to test confined<br />
spaces from a safe area prior to entry. Supplied in carry case complete with<br />
training video and battery charger. Other sensor options available at extra<br />
cost. battery pack run time 8h (18h with lithium batteries).<br />
ISC ITX 4-Gas Monitor Confined Space & Logging<br />
ISC,ITx-STD AU<br />
Multi-gas monitor with confined-space kit and logging option. Configured<br />
for 4 gases: combustible 50ppm~100%LEL, oxygen 0~30%, CO 0~999ppm<br />
& H 2 S 0~999ppm. Intrinsically safe: Ex ia d I/IIC T4[Australia]. Confined<br />
space kit includes motorised pump, tubing, calibration cup and regulator.<br />
Logging option by time or event, up to 300h survey data at 1min intervals,<br />
with datalink/software for download. Includes training video, Li-ion battery<br />
pack with charger, and backup alkaline-battery pack.
did yOu knOW….<br />
yOu can Obtain<br />
quOteS Online,<br />
quickly and<br />
eaSily, With Our<br />
perSOnaliSed<br />
quOting SyStem?<br />
viSit Our WebSiteS,<br />
brOWSe the<br />
catalOgue and<br />
Select the<br />
prOductS yOu are<br />
intereSted in – it<br />
cOuldn’t be eaSier.<br />
www.techrentals.com.au<br />
www.techrentals.co.nz<br />
www.techrentals.com.my<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
gaS analySiS & mOnitOring<br />
GasCheck 3000 Portable General-purpose Leak Detector<br />
ION,GASCHECK3000 AU<br />
portable leak detector. Micro thermal-conductivity sensor for high-sensitivity<br />
detection of gases with a thermal conductivity different to that of air, including<br />
helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural gas, etc in<br />
five groups. Direct reading of leak rate in ml/s with audio and visible signals.<br />
Detection limit for helium 2E-5ml/s. battery powered.<br />
RAE Systems Minirae 2000 Portable PID<br />
RAE,MR2000 AU<br />
Portable handheld VOC (Volatile Organic Compound) monitor with data<br />
logging. 3-D pID sensor (photo-Ionisation Detector) fitted with 10.6eV lamp.<br />
Ranges 0~999ppm (resolution 0.1) or 100~10,000ppm (resolution 1) VOC<br />
expressed as isobutylene. built-in correction factors for 102 compounds<br />
from a total standard library of 250. Integrated pump for local or remote<br />
(30m) sampling, with stall protection against liquid ingress. Downloadable<br />
data logging for 1,500 points with time, data and header. Intrinsically safe.<br />
Up to 10h operation with rechargeable (NiMH) or alkaline batteries.<br />
Novatech O and CO Analyser/Transmitter<br />
2 2<br />
NOV,1637-5 AU<br />
Oxygen and carbon dioxide analyser for packaging atmosphere, general<br />
industrial and research use. Oxygen sensor reading 1ppm to 100% with<br />
1% accuracy. NDIR carbon dioxide analysis 0~100% ±3% of full scale. 2<br />
x 4~20mA outputs, 1 common & 3 selectable alarm relays. Gas connection<br />
1/8 Swagelok. Flow rate with internal pump 100~500cc/min. AC operation.<br />
ISC MDU420 Logging Methane Monitor<br />
ISC,MDU420 AU<br />
Dual-range methane monitor with non-dispersive infrared sensor. Low range<br />
0~100% LEL, and auto-range 0~100% methane by volume. Internal pump<br />
for ambient air or stream sampling. Datalogging included, with software and<br />
cable for download. Supplied with 450mm stainless steel probe for flue gas<br />
analysis. Rechargeable, with alkaline-battery pack as backup.<br />
> NEW<br />
Odalog NO2 & CO Area Monitor for vehicle-parks & IAQ<br />
ApT,ODA6000Cp AU<br />
portable multi-gas monitor for area air-quality measurement, logging<br />
or personal monitoring in car-parks, loading areas and related zones.<br />
Configured for carbon monoxide (from petrol vehicles) and nitrogen<br />
dioxide (from diesel vehicles). Ranges CO 0~500ppm (to 1ppm) and NO2 0~50ppm (to 0.1ppm). Dust and water sealed to Ip66, and rated intrinsically<br />
safe for general or mines use. Logging memory 500K readings. Integral<br />
infrared communications interface, with software and IrDA USb adaptor for<br />
configuration and download. Rechargeable, approximately 7 days operation<br />
on full charge.<br />
GAS ANALYSIS<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 127
GENERAL ENVIRONMENTAL<br />
128<br />
electrOchemiStry, Water quality<br />
> NEW<br />
Anton Paar DMA 35N Portable Density Meter<br />
pAA,DMA35N AU<br />
Portable density, specific gravity & concentration meter. Measuring range<br />
0.000~1.999 g/cc and 0.0~40.0ºC. built-in pipette style pump for sample<br />
aspiration, with port for optional syringe-filling. Display of specific gravity,<br />
ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically<br />
safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage<br />
of up to 1024 results, with recall, and infrared port for RS232 download to<br />
serial printer or PC. Wetted parts glass and PTFE. Battery powered.<br />
> NEW<br />
TPS WP-80 pH and Temperature Meter<br />
TpS,Wp-80 AU<br />
portable hand-held meter for pH, mV and temperature. Supplied with<br />
combination pH electrode and separate temperature sensor on 1m cables.<br />
Operating ranges 0.00~14.00pH and -10.0~120.0ºC [automatic sensor<br />
recognition with auto pH correction 0~100ºC]. Case water resistant to Ip67,<br />
connectors to Ip65. Menu driven, with alphanumeric display. Auto storage<br />
of time and date of last calibration for GLp. Memory for 2400 readings of<br />
data, time and date, for Notepad results collection, or for AutoLog with<br />
logging intervals between 1 sec and 90 hr. Fitted with RS232C interface<br />
and supplied with download-software, charger and solutions. Rechargeable<br />
NiMH battery gives up to 50 hr operation.<br />
TPS LC80A Portable pH Meter<br />
TpS,LC80A AU<br />
battery operated with LCD display. Automatic temperature compensation,<br />
and analogue recorder output. Complete with combination electrode/<br />
temperature probe with a max temperature of 60OC. Display has ranges:<br />
0~14ph, 0~199mV, & -10~199OC. TPS Redox Electrode<br />
TpS,REDOx AU<br />
Silver/chloride Redox electrode for use with TpS LC80A ph meter. Supplied<br />
with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx.<br />
231mV.<br />
TPS WP-88 Turbidity & Temperature Meter with 8m Cable<br />
TpS,Wp88 AU<br />
portable hand-held turbidity and temperature meter for field or laboratory<br />
use. Sensor probe diameter 45mm, with 8m cable. Turbidity ranging 0.1~<br />
200/2000NTU ±1NTU with autoselection. Temperature compensation and<br />
sensor range 0~ 60ºC ±0.1ºC. Case water resistant to Ip67, connectors to<br />
IP65, with detachable cable and sensor. Menu driven, with alphanumeric<br />
display. Auto storage of time, date and results of last calibration for GLp.<br />
RS232C interface, and memory for 150 readings of data, time and date,<br />
for Notepad results collection, or for AutoLog results collection with logging<br />
intervals between 1min and 24h. Rechargeable NiMH battery gives up to<br />
50h operation. Supplied with download-software, charger and calibration<br />
solutions.<br />
TPS WP-82 Dissolved Oxygen Meter<br />
TpS,Wp82 AU<br />
portable hand-held dissolved oxygen and temperature meter. Operating<br />
ranges 0~20ppm, 0~240% saturation, 0~45% gaseous and ppm with salinity<br />
correction. temperature range -10~120 O C. Case water resistant to IP67,<br />
connectors to IP65, with 3m detachable cable and ED1 electrode. Menu<br />
driven, with alphanumeric display. Auto storage of time and date of last<br />
calibration for GLP. RS232C interface, and memory for 150 readings of<br />
data, time and date, for Notepad results collection, or for AutoLog results<br />
collection with logging intervals between 1min & 24h. Rechargeable NiMH<br />
battery gives up to 75h operation. Supplied with download-software, charger<br />
and solutions.
TPS WP-84 Conductivity Salinity Temperature Meter<br />
TpS,Wp-84 AU<br />
portable hand-held meter for conductivity, TDS (Total Dissolved Solids) and<br />
temperature. Automatic range selection with 5 ranges. Case water resistant<br />
to Ip67, connectors to Ip65. Menu driven, with alphanumeric display for fulltext<br />
prompting. Storage of time and date of last calibration for GLP. Memory<br />
for 150 readings of data, time and date, for Notepad results collection, or<br />
for AutoLog results collection with logging intervals between 1min & 24h.<br />
Rechargeable NiMH battery gives up to 75h operation. Supplied with sensor<br />
(k=1), charger and solutions.<br />
YSI 55D Dissolved Oxygen Meter<br />
YSI,55D NZ<br />
Measures dissolved oxygen in mg/L or percent saturation. Range is 0~20mg/<br />
L, resolution is 0.01mg/L, accuracy is 0.3mg/L. provides simultaneous<br />
readings of O2 & OC. Dissolved O2 readings are automatically compensated<br />
for temperature. Offering push-button calibration with a built-in calibration<br />
chamber, direct salinity, and altitude compensation. Supplied with 3m cable<br />
to probe.<br />
YSI 550A Dissolved Oxygen Meter with 12ft Cable<br />
YSI,550A NZ<br />
Handheld microprocessor based dissolved oxygen meter for use in fresh<br />
water, sea water or polluted water. Range 0~50mg/l resolution is 0.01 or<br />
0.1. Air saturation range is 0~500% resolution is 0.1 or 1 air saturation.<br />
Temperature range is -5°C~45°C resolution is 0.1. Features: Self-diagnostics<br />
on power up. Compensation for altitude, salinity & temperature, waterproof<br />
to Ip-67, push-button calibration, built-in calibration cha mber. Over 2,000h<br />
(alkaline) battery life at 25°C. Supplied with 4m probe lead.<br />
YSI 63 pH Salinity and Conductivity Meter<br />
YSI,63-10 NZ<br />
Measures temperature, pH, conductivity, and salinity. Ranges are: 0~14pH,<br />
resolution 0.01, conductivity is 0~200mS/cm over 4 ranges, salinity is<br />
0~80 ppt, resolution 0.1, temperature is -5~75OC, resolution 0.1. Stores<br />
50 readings with ID, user-selected scale or autoranging for conductivity.<br />
Supplied with a 15m cable to probe.<br />
Horiba U-20 Multi-function Water Quality Meter<br />
HOR,U-20xD1 AU<br />
Multi-parameter water quality monitor with 30m cable. Waterproof Meter<br />
unit rated to IP67 with LCD display, analog output and RS232C interface for<br />
data download using software supplied. Detachable probe, 47mmØ with<br />
stainless steel cover suitable for use in 50mm wells, with sensors for pH/<br />
ORp, dissolved oxygen, conductivity/salinity/TDS/seawater specific gravity,<br />
temperature, turbidity and depth. Data logging up to 1m @ 15min intervals.<br />
Alkaline battery operation.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
electrOchemiStry, Water quality<br />
Hydrolab Quanta Multiprobe Water Quality Meter<br />
HYD,QT-Mp-A AU<br />
Multi-parameter water quality analyser with 15m cable. Meter unit rated to<br />
NEMA6 (waterproof), with simultaneous parameter display, realtime manual<br />
storage of 100 frames of data and SDI interface. Transmitter probe with<br />
sample circulator, fitted with sensors for temperature, specific conductance/<br />
salinity, dissolved oxygen, pH, ORp and turbidity. Operates on 3 x C size<br />
batteries.<br />
TPS Water Quality Meter<br />
TpS,90FL-T AU<br />
Field meter and logger for water quality measurements. Configured with<br />
independent probes for pH, conductivity/salinity[TDS]/temperature, dissolved<br />
oxygen[DO] and turbidity. Cables 5m with probe holder and safety harness.<br />
LCD display readout with simultaneous display of all measurements.<br />
Manual, “notepad” storage or automated data logging for up to 1,808 sets<br />
of readings by time and date. RS232C interface, with WinTPS software<br />
included. Supplied with rechargeable battery, and clip-lead for operation<br />
from a 12V source such as a car-battery.<br />
Hanna Portable Turbidity Meter with Case & Kit<br />
HAN,HI93703C AU<br />
Microprocessor-based, portable turbidity meter operating in the range 0~<br />
50FTU x 0.01FTU or 50~1,000FTU x 1FTU(NTU). Long-life IR LED source<br />
peaking at 890 nm for reduced colour-interference. Compliant with ISO7027<br />
requirements. Unique GLp feature allows automatic storage and recall<br />
of last calibration value with time and date. Supplied in carry-case with<br />
measuring cuvettes, and maintenance kit. battery operation.<br />
GENERAL ENVIRONMENTAL<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 129
GENERAL ENVIRONMENTAL<br />
130<br />
electrOchemiStry, Water quality<br />
Analite NEP160-1 Turbidity Meter<br />
ANA,NEp160 NZ<br />
Portable turbidity meter suitable for potable or waste water measurements<br />
depending on the probe type. Supplied with either NEp280 100~20,000NTU<br />
waste water retro-scatter probe on a 5m cable or NEp260 0~3,000NTU<br />
potable water probe with 25m cable. Display resolution for the NEP280<br />
probe is 10NTU, NEp260 probe is 1NTU. Repeatability is ±2% +1 digit on<br />
all ranges. Data logging up to 100 time & date stamped readings with sample<br />
intervals from 1s~90min. Analogue output with a range of 0~2V fs on any<br />
range. RS232C interface which can output readings on request or at preset<br />
intervals from 1~99s or min.<br />
DKK TOA Model RC-24P Portable Residual Chlorine Meter<br />
DKK,RC-24p-Dp AU<br />
portable, direct-reading residual chlorine meter for water analysis. Range<br />
0~2mg/L [ppm]. Reagent-free measurement with electrode, 3m cable, float<br />
and sample container for in-situ or grab-sampling. Compatible with direct<br />
chlorination, hypochlorite or dichloroisocyanurate dosing. Calibration data<br />
stored in electrode with correlation with DPD methods. Waterproof to IP67.<br />
ISO validation functions, storage of 300 measurements and RS232 printer<br />
output. Battery operated.<br />
Aquafluor Handheld Fluorimeter for Rhodamine WT &<br />
Fluorescein<br />
TUR,AQF-RF AU<br />
Dual-channel handheld field fluorimeter. Configured for water-tracing by detection<br />
of rhodamine WT and fluorescein dyes, detection limit ~0.4ppb. RWT channel<br />
excitation 540nm, emission >570nm; Fluorescein channel excitation 475nm,<br />
emission 515nm. Internal data logging for 1000 data points, with download.<br />
Battery operated.<br />
Spectronic Helios Epsilon Spectrophotometer Visible<br />
SUV,EpSILON1 AU<br />
Single beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth,<br />
operating in the range -0.1~2.5A. Wide view-angle LCD display and<br />
sealed membrane keypad with push button auto-zero. Sealed optics,<br />
with wavelength slew >4500nm/min. Operational modes absorbance,<br />
transmission, concentration and factor. Supplied with standard cellholder<br />
for 10mm square cells. RS232C port for computer and parallel interface<br />
for printer.<br />
Van Essen Depth/Temperature Groundwater Logger 30M<br />
VAN,TD30 AU<br />
Groundwater depth and temperature logger for operation to 30m. Independent<br />
probe 22mmØ x 125mm long with internal memory for 2 x 24,000 measurements,<br />
battery-life 8~10y. Reader for set-up and download of data using standard<br />
computer. Supplied with “baro Diver” - ambient/surface logger for atmospheric<br />
pressure correction.<br />
Isco 6700 Series Water Sampler with Bubbler Flow Module<br />
ISK,6700-730 AU<br />
Advanced water sampler for fully programmed collection. Samples can<br />
be collected in 1, 2, 8, or 24 glass or plastic sample containers based on<br />
time, flow, and/or parameter set points. Fitted with NEMA 4x,6 (Ip67) sealed<br />
controller featuring an exclusive, built-in pump, flash memory for easy<br />
programming changes, and a plug-in module port for connection of a flow<br />
meter module or parameter measurement module to enhance monitoring<br />
capabilities. Provided with bubbler flow module. Sample bottles available.<br />
Run from rechargeable 12V sealed batteries.
Shimadzu UV-Mini 1240 Spectrophotometer UV-Visible<br />
SHI,UV-1240 AU<br />
Single beam scanning UV-visible spectrophotometer, 190~1,100nm with<br />
5nm bandwidth. Large LCD display for on-screen viewing of results,<br />
calibration curves and spectra. Standard applications include photometric<br />
measurement, spectrum scanning and quantitation. IC data card system for<br />
storage of raw data, methods and results, with optional program packs for<br />
additional applications. Interface ports for printer or computer. 220~240V,<br />
50/60Hz.<br />
Spectronic Helios Epsilon Spectrophotometer Visible<br />
SUV,EpSILON1 AU<br />
Single beam visible spectrophotometer, 325~1,000nm with 8nm bandwidth,<br />
operating in the range -0.1~2.5A. Wide view-angle LCD display and<br />
sealed membrane keypad with push button auto-zero. Sealed optics,<br />
with wavelength slew >4500nm/min. Operational modes absorbance,<br />
transmission, concentration and factor. Supplied with standard cellholder<br />
for 10mm square cells. RS232C port for computer and parallel interface<br />
for printer.<br />
> NEW<br />
Anton Paar DMA 35N Portable Density Meter<br />
pAA,DMA35N AU<br />
Portable density, specific gravity & concentration meter. Measuring range<br />
0.000~1.999g/cc and 0.0~40.0ºC. built-in pipette style pump for sample<br />
aspiration, with port for optional syringe-filling. Display of specific gravity,<br />
ºbrix, ºbaumé, %alcohol, proof, ºplato, ApI, or %H2SO4. Rated intrinsically<br />
safe [ATEx] for use with batteries, petrochemicals and solvents. Data storage<br />
of up to 1024 results, with recall, and infrared port for RS232 download to<br />
serial printer or PC. Wetted parts glass and PTFE. Battery powered.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
SpectrOScOpy<br />
X-Rite SP60 Portable Sphere Colour Spectrophotometer<br />
xRI,Sp60 AU<br />
Portable spectrophotometer for surface colour measurements. Diffuse<br />
8 O [d/8] optical geometry with fixed 8mm aperture. Tungsten source<br />
for illuminant types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard<br />
observers 2 & 10 O . blue-enhanced photodiode detectors with spectral<br />
range 400~700nm. Measures opacity and colour by chromatic, apparent<br />
or tristimulus calculation, with simultaneous included and excluded specular<br />
component, and spectrum at 10nm intervals. Storage of up to 2,000 samples<br />
with results download to serial printer or computer. Operation from internal<br />
rechargeable battery or ac adaptor.<br />
materialS teSting<br />
Hydramotion Viscolite 700 Portable Viscometer<br />
HYL,V700S-21 AU<br />
Advanced portable viscometer with stainless-steel probe. Operating range<br />
0.1~10,000mpaps (cps) with integral temperature correction -40~150ºC.<br />
probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm<br />
(viscosity/temperature). Acetal polymer probe base for handheld or clamped<br />
operation, with coiled-cable connection to meter unit with 5 digit display.<br />
Battery powered.<br />
GENERAL ENVIRONMENTAL<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 131
did yOu knOW….<br />
yOu can regiSter<br />
Online tO receive<br />
advance nOtice<br />
Of neW prOductS,<br />
prOmOtiOnS and<br />
technical neWS?<br />
viSit Our WebSite<br />
and regiSter<br />
tOday.<br />
www.techrentals.com.au<br />
www.techrentals.co.nz<br />
www.techrentals.com.my
CALIBRATION
CALIBRATION<br />
134<br />
calibratiOn ServiceS. Online. Ontime. everytime.<br />
<strong>TR</strong> <strong>Corporation</strong> services also include calibration. These services<br />
are delivered through TECH<strong>RENTAL</strong>S and VMS.<br />
Our laboratories are staffed by experienced technical engineers<br />
and technical officers to provide internationally recognised calibration<br />
services. Utilising state-of-the-art specialised instrumentation, each<br />
is NATA accredited, with ISO quality systems in place for traceability<br />
and control.<br />
Our ServiceS:<br />
• calibration<br />
• rEpairs<br />
• salEs<br />
• total assEt<br />
managEmEnt<br />
• mobilE calibration<br />
facilitiEs<br />
induStrieS SuppOrted:<br />
• aviation<br />
• dEfEncE<br />
• ElEctrical<br />
• ElEctronic<br />
• biomEdical<br />
• mEchaical<br />
• tElEcommunications<br />
Why deal With uS:<br />
• ExpEriEncEd,<br />
qualifiEd staff<br />
• nata accrEditation<br />
• iso quality control<br />
• 22 convEniEnt<br />
locations<br />
• onlinE sErvicEs<br />
(australia only)<br />
• onE stop shop<br />
facility for all your<br />
calibration nEEds<br />
talk to your<br />
tEchrEntals<br />
consultant<br />
about how wE<br />
can hElp solvE<br />
your calibration<br />
problEms
a<br />
AC See Electrical<br />
Accelerometer 88-89<br />
Acoustic Spectrum Analysis 119<br />
Adhesion Tester 91<br />
Air<br />
Compressor Output 112<br />
Flow 112-117<br />
Quality 113-115, 117<br />
Air Conditioning<br />
Coolant Flow 110, 112<br />
Electronic Manifold 118<br />
Measurement 113-114<br />
Valve Balancing 118<br />
Air Quality<br />
Monitoring 113-115, 117, 126<br />
particles 113-114, 117<br />
Temperature & Humidity 113-114, 117<br />
Air Velocity Meter 112, 115<br />
Alcohol breath Analyser 122<br />
Alignment 88-89<br />
Ammeter 60, 62<br />
Amplifier Instrumentation 73<br />
Anemometer 113-115, 116<br />
Angle Measurement 63<br />
Antenna & Cable Test 18-19<br />
Antennas 19-20, 37<br />
Appliance Tester 46-47<br />
Area Heat Stress 113-114, 117<br />
Audio Analyser 26<br />
Autoclave Logger 70, 73<br />
Automotive Testing 90<br />
b<br />
Balances 85, 87<br />
Balancing Machinery 118<br />
balancing Machinery Analyser 88<br />
balometer 113-114, 115<br />
Barometric 102<br />
Barometric Recorder 102<br />
Bath<br />
Constant Temperature 94-95, 97<br />
Ultrasonic 100<br />
Bit Error Rate (BERT) 28<br />
Blast Logger 90<br />
body Vibration Measurement 88-89<br />
Bore Hole Depth 130<br />
Bore Hole Water Quality 129<br />
Borescope 79, 81<br />
brake Tester 90<br />
Bridge LCR 9<br />
c<br />
Cable<br />
Fault Locator 36-37<br />
LAN Test 32<br />
Locator 32, 36-37<br />
Tester 32, 36-37<br />
Tracer 36-37<br />
Cable Locator 36<br />
Cable Tester 36<br />
Cable TV 27<br />
Calibrator<br />
Current 94-97<br />
Current Loop 94-96, 98<br />
Dry block Temperature 94-95, 97-98<br />
Electrical 9<br />
Hydraulic 94-95, 99-100<br />
Industrial 94-95<br />
Loop 94-95<br />
pneumatic Instruments 94-95, 98<br />
pressure 94-95, 98-100<br />
process 94-96<br />
Resistance 94-96<br />
Temperature 94-95, 97-98<br />
Voltage 94-96, 98-99<br />
Caliper 78<br />
Camera<br />
Digital 106<br />
Endoscope 79, 81<br />
High Speed 82<br />
pipe Inspection 79-81<br />
Surveillance 106<br />
Thermal Imaging 104-105<br />
Video 82<br />
Carbon Dioxide (CO 2 )<br />
113-114, 117, 124-127<br />
Carbon Monoxide (CO)<br />
113-114, 117, 124-126<br />
Cat 5, 5E, 6 32<br />
CCTV Surveillance 106<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
Charge Amplifier 88-89<br />
Chart Recorder 76, 82-83<br />
Circuit breaker Analyser 58<br />
Circuit Tracer 36<br />
Clean Room Monitor 117<br />
Cleaver - Fibre Optic 35<br />
Coating Thickness 90-92<br />
Coil & Winding Test 41, 46<br />
Combustion Gas Analysis 123-126<br />
Communications Test Set 21<br />
Compressed Air Flow 112<br />
Compressor Output<br />
Flow 105<br />
Quality 105<br />
Concrete Testing<br />
Adhesion 91<br />
Cover Meter 92<br />
Moisture Meter 92-93<br />
Reo Depth 92-93<br />
Test Hammer 92-93<br />
Ultrasonic Tester 91-92<br />
Conductivity & Salinity 129<br />
Confined Space Entry 123, 126<br />
Counting Scales 87<br />
Crane Scales 86<br />
Current<br />
Clamp 46, 53-54, 57, 60-65, 75<br />
DC Source 7<br />
Injection 65<br />
Input Logger 70, 73<br />
Loop 94-95, 96-98<br />
Meter 48-49, 56, 60, 62-63, 110-111<br />
Primary Injection 65<br />
probe 4, 61-62<br />
Secondary Injection 65<br />
Sensor 75<br />
Shunt 60, 63<br />
Transducer 53, 60, 63, 75<br />
Transformer (CT) 48-49, 51, 56, 60<br />
d<br />
Data Communications<br />
Cable Test 32<br />
Etherscope 29<br />
Fibre Optics 33<br />
LAN Analyser 29<br />
Protocol analyser 31<br />
protocol Analyser 28, 30-31<br />
WAN analyser 31<br />
WAN Analyser 29, 31<br />
Data Logger 70-73, 83<br />
DC High Voltage 4, 59<br />
DC Power Supplies 7<br />
Decade Resistance Box 9<br />
Demand Analyser 48-49, 51, 56<br />
Density Meter 86, 128, 131<br />
Depth Logger 130<br />
Dewpoint 105, 113-114, 117<br />
Digital Camera 106<br />
Digital Storage Oscilloscope 2<br />
Dimension Measurement 78<br />
Dissolved Oxygen 128-129<br />
Distance Measurement 78<br />
Distortion Analyser/Generator 26<br />
Dose Meter (Noise) 120-121<br />
Dust Measurement 113-114, 117<br />
e<br />
E1/E3 Tester 28-31<br />
Earth Leakage 41- 45, 48-49, 59-60, 62, 65<br />
Earth Tester 46<br />
Electric Motor Test 46<br />
Electrical 40<br />
Electrical Cable Test 41-45, 59<br />
High Voltage 59, 65<br />
Surge Generator 36<br />
TDR 36<br />
VLF 59<br />
Electrical Installation & Test<br />
Appliance Tester 46-47<br />
Earth Leakage (RCD)<br />
41-46, 48-49, 60, 62, 65<br />
High Voltage Test (Hi-pot) 46, 59<br />
Insulation Test 40-45, 59<br />
Phase Rotation 63<br />
Resistance Test 41-45, 46<br />
Soil/Ground Resistance 41, 45-46<br />
Electrical Power Generation<br />
& Transmission<br />
Current Injection 65<br />
High Voltage Test (Hi-pot) 59<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
power Quality 48-54, 56<br />
Protection Relay Test 57<br />
VLF Test 59<br />
Electrical Power Quality<br />
Demand Analyser 51-54, 56<br />
Harmonics 48-49, 51, 56<br />
power Factor 48-49, 51, 53-54, 63<br />
power Quality Analyser 48-50, 53-56<br />
Voltage Current Recorder 76<br />
Electrical Power Sources<br />
Current Injectors 65<br />
Generator 68<br />
Line Conditioners 66<br />
UpS 66-67<br />
Electrical Testers 63<br />
Electrical Transducers 60, 62<br />
Electrochemistry 128<br />
Electrometer 5<br />
Electrostatic Charge Measurement 6<br />
EMC/EMI Test Equipment 21<br />
Endoscopes 79-81<br />
Environmental Chambers/Oven 100-101<br />
Environmental Noise 120, 122<br />
Ethernet Analyser 29-30<br />
f<br />
Fibre Optic Microscope 35<br />
Fibre Optics 33-34<br />
Fusion Splicer 35<br />
LAN Cable Test 32<br />
OTDR 34<br />
PMD 35<br />
power Meter/Light Source 33-35<br />
Field Strength Meter<br />
Gauss 40<br />
RF 19-20<br />
Field Strength Meters & Antennas 19-20<br />
Filters 26<br />
Flash Card 75<br />
Flaw Detector 90<br />
Floor Slip Tester 122<br />
Flow Meters 110-112<br />
Compressed Air 110, 112<br />
Doppler 110-112<br />
Gas 110, 112<br />
Liquid 110-112<br />
Non-Intrusive 110-112<br />
Open Channel 110-112<br />
Transit Time 110, 112<br />
Ultrasonic 110-112<br />
Flue Gas Analysis 123-125<br />
Flue Inspection 79-80<br />
Fluorimeter 130<br />
Force Gauge 84<br />
Formaldehyde Meter 123, 125<br />
Frequency Counter 12<br />
Frequency Response Analysers 10<br />
Frequency Transducer 60, 63<br />
Function Generator 8<br />
Fusion Splicer 35<br />
g<br />
Gamma Radiation 19-20<br />
Gas<br />
Alcohol 122<br />
Carbon Dioxide (CO 2 ) 117, 124-127<br />
Carbon Monoxide (CO) 117, 123-127<br />
Flammable (LEL) 125-126<br />
Formaldehyde 123, 125<br />
Hydrogen Sulphide (H 2 S) 125-126<br />
Methane (CH 4 ) 123, 125-127<br />
Nitric Oxide (NO) 117, 123-126<br />
Nitrogen Dioxide (NO 2 ) 123-127<br />
Oxygen (O 2 ) 123, 126-127<br />
Ozone (O 3 ) 125<br />
Refrigerant 118<br />
Sulphur Dioxide (SO 2 ) 123<br />
VOC 123, 127<br />
Gas Analysis &<br />
Monitoring 123, 125-127<br />
Gauss/Tesla Meter 40<br />
Generator (AC) 68<br />
Glossmeter 90<br />
GpIb Interface 4<br />
Ground Vibration 90<br />
Groundwater 130<br />
h<br />
Hardness Tester 93<br />
Harmonics (power) 48-50, 56<br />
Heat Stress 113-114, 117<br />
High Voltage Insulation Dielectrics<br />
Test Set 42<br />
Hi-pot Tester 46, 59<br />
Holiday Detector 91<br />
Hot Wire Anemometer 113-114, 116<br />
Humidity<br />
Chamber 101<br />
Concrete 92<br />
High Temp probe 77, 83-84<br />
Indoor Air 113-114, 117<br />
Logging 70, 72-73<br />
Natural Gas 105<br />
Recorders 102<br />
Thermohygrograph 102<br />
Transducer 77, 83-84<br />
Weather 118<br />
HVAC & IAQ 112-117<br />
Hybrid Recorders 76<br />
Hydraulic pressure 91, 94-95, 99-100<br />
i<br />
Illuminance Meter 119<br />
Inclinometer 84<br />
Indoor Air Quality 113-114, 117<br />
Infrared Camera 104-105<br />
Infrared Thermometer 102-103<br />
Injection Test Set 65<br />
Instrumentation Amplifier 73, 76<br />
Insulation Tester 41-45, 59, 65<br />
Intrinsically Safe<br />
Current Loop Calibrator 94-95, 98<br />
Digital Multimeter 6<br />
Gas Monitor 126<br />
Moisture Analyser 105<br />
Noise Dose Meter 120-121<br />
photo-Ionisation Detector (pID) 123, 127<br />
Inverter 68<br />
Ionisation Tester 59<br />
ISDN 28, 31<br />
l<br />
Laboratory Oven 101<br />
LAN<br />
Analyser 29-31<br />
Cable Certification 32<br />
Cable Tester 32<br />
Laser<br />
Distance & Speed 78<br />
Level 78<br />
LCR Meter 9<br />
Leak Detector<br />
Gas Pipe 37, 118, 125, 127<br />
Microwave Oven 19-20<br />
Refrigerant 118<br />
Water 37<br />
Light Measurement 119<br />
Light Meter 119<br />
Linear position Transducer 84<br />
Load Cell 85-86<br />
Logger 70<br />
Accessories 71<br />
Autoclave 70, 73<br />
Data 70-73, 83<br />
Environmental Noise 120, 122<br />
Explosion 90<br />
Flow 110-111<br />
Ground Vibration 90<br />
Humidity 70, 72-73<br />
Oven 70<br />
Pressure 102<br />
Shipping & Transport 89<br />
Temperature 70-73<br />
Logic Analyser 10<br />
Logic Programmer 10<br />
Low Frequency<br />
Frequency Response Analysers 10<br />
Signal Generator 26<br />
Luminance Meter 119<br />
Lux Meter 119<br />
m<br />
Machinery<br />
Balancing 88<br />
Vibration 88-89<br />
Magnetic Field Meter 40<br />
Manometer 114-115<br />
Materials Testing 86, 128, 131<br />
Memory Recorder 73-75<br />
Metal Detector 106-107<br />
Methane Monitor 123, 127<br />
Micro-Ohm Meter 41-43<br />
GENERAL INDEX<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 135
GENERAL INDEX<br />
136<br />
Microscope 82<br />
Microwave Leakage Detector 19-20<br />
Microwave Oven Survey Meter 19-20<br />
Modified Atmosphere<br />
packaging Test 123, 127<br />
Modulation Meter 20<br />
Moisture<br />
Concrete 92-93<br />
Timber 92<br />
Moisture Balance 87<br />
Multimeter 5-6<br />
n<br />
Natural Gas 105<br />
Network Analyser<br />
Antenna & Cable Test 18-19<br />
LAN/WAN 29<br />
power 48-49<br />
RF 13, 18, 26<br />
Telecommunications 28<br />
Noise & Sound 120<br />
Noise Dose Meter 120-121<br />
Noise Logger 120, 122<br />
Non-Destructive Testing<br />
(NDT) 88, 90-92<br />
Non-Storage Oscilloscope 3<br />
O<br />
Occupational Health & Safety 119, 122<br />
Air Quality 113-114, 117<br />
Appliance Testing 46-47<br />
Confined Space Entry 123, 125-126<br />
Floor Slip Tester 122<br />
Formaldehyde 123, 125<br />
Heat Stress 113-114, 117<br />
Lighting 119<br />
Noise & Sound 120<br />
Ozone 123, 125<br />
Radiation 19-20<br />
Toxic Gas 123, 125, 127<br />
UV Exposure 119<br />
Vibration 88<br />
Oil Insulation Tester 41, 46<br />
Optical Networking<br />
DWDM 35<br />
Optical Spectrum Analysis 35<br />
Oscilloscopes<br />
Digital Storage 2-3<br />
Non Storage 3<br />
portable 2-3<br />
probes 4<br />
OTDR 34<br />
Oven 101<br />
Oven Logger 70<br />
Oxygen & CO 2 Analyser 123, 125, 127<br />
Oxygen (O 2 ) 123, 125, 127<br />
Ozone (O 3 ) 123<br />
Ozone Monitor 123<br />
p<br />
particle Counter 113-114, 117<br />
pAT 46, 47<br />
PCM Test Equipment 28<br />
pDH Analyser 28<br />
People Counter 107<br />
Petrol Generator 68<br />
pH Measurement 128<br />
phase Angle 63<br />
Phase Rotation Meter 63<br />
Phase Sequence Meter 63<br />
photo-Ionisation Detector (pID) 123, 127<br />
Pinhole Detector 91<br />
Pipe Locators 36<br />
Pipeline Inspection 79<br />
Pitot Tube 115<br />
Plotter Printer 76<br />
Polarisation Mode Dispersion (PMD) 35<br />
portable Appliance Tester 46, 47<br />
position Transducer 84<br />
POTS 28<br />
Power See Electrical<br />
power Analyser 48-49, 51-56, 63<br />
Power Demand<br />
Analyser 48-49, 51-54, 56<br />
power Disturbance 48-49, 51, 56<br />
Power Line Conditioner 66<br />
power Supplies - DC 7<br />
Pressure<br />
Calibrator 94-95, 97-100<br />
Circular Chart Recorder 82-83<br />
Indicator/Gauge 77, 82-83<br />
Transducer 77, 83<br />
Probe<br />
Current 4, 48-51, 57, 61-62<br />
Digital 75<br />
Frame Relay 31<br />
High Voltage 4<br />
Line Logic 75<br />
Static Detector 6<br />
process Calibrator 96-98<br />
Programmer<br />
EPROM, EEPROM 10<br />
Protection Relay Test 57<br />
protocol Analyser 28, 30-31<br />
Pulse Crest Meter 91<br />
Pulse Generator 9<br />
Pulse Porosity Detector 91<br />
pump 94-95, 98-100<br />
r<br />
Radar Speed Gun 78<br />
Radiation Monitor 19-20<br />
Radiometer 119<br />
Random Noise Generator 26<br />
RCD Test 41, 45<br />
Recorders 70<br />
Barometric 102<br />
Chart 76, 82-83<br />
Hybrid 76<br />
Memory 73-75<br />
Pressure 82, 83<br />
Tape 76<br />
Temperature Humidity 72<br />
Rectifier 7<br />
Refrigerant Leak Detection 118<br />
Relative Humidity 102<br />
Also See Humidity<br />
Relay Test 57, 65<br />
Resistance<br />
Calibration 94-95<br />
Decade 9<br />
Ground/Soil 45-46<br />
Micro-Ohm 41-43<br />
Static 41, 46<br />
Tester 41-46<br />
Retail Traffic Flow Counter 107<br />
RF & Microwave<br />
Accessories 26<br />
Amplifier 13<br />
Antenna/SWR 18-19<br />
Antennas 18-20<br />
Attenuator 25-26<br />
Communications Test Set 21<br />
EMC/EMI Test 14, 17, 20-21<br />
Field Strength Meters 19-20<br />
Frequency Counter 12<br />
Function Generator 8<br />
Modulation Meter 20<br />
Network Analyser 13, 18-19<br />
power Meter 22-23<br />
power Sensors 24<br />
Radiation Monitor 19-20<br />
Sensor 22, 24<br />
Signal Generator 13, 20<br />
Spectrum Analyser 10, 14, 17<br />
Sweep Generator 13<br />
Voltmeter 22<br />
Rogowski Coil 48-49, 53<br />
Rotating Balancing 89<br />
Rotating Laser Level 78<br />
Roughness 91<br />
Router Test System 31<br />
RTD Calibrator 94-95<br />
S<br />
Salinity & Conductivity 129<br />
Scales 85-87<br />
Scopemeter 2-3<br />
Security<br />
Bug Detector 106<br />
Metal Detector 106<br />
Surveillance 106<br />
Shaft Alignment 88-89<br />
Shaker Table 88, 90<br />
Signal Generator<br />
Low Frequency 26<br />
RF 13<br />
Signalling Analyser 28<br />
Smoke Generating Machine 114<br />
Sniffer 30<br />
Soil Resistivity 41, 46<br />
Sonde 37<br />
Sound 120<br />
Dose Meter 120-121<br />
Logger 120-122<br />
Measurement 120<br />
Signal Analysis 119<br />
Sound Level Meter 88-89, 120-122<br />
Vibration 88-89<br />
Spectrophotometer 130-131<br />
Spectroscopy 131<br />
Spectrum Analyser<br />
Acoustic 119<br />
Optical 35<br />
RF 10, 14-15, 17<br />
Speed Measurement 78<br />
Splicer - Fibre Optic 35<br />
SS7 28<br />
Startup Current 48-49, 51-54<br />
Static Detector Probe 6<br />
Static Discharge Generator 21<br />
Step Transformer 21<br />
STM1 ... STM65 28, 31<br />
Strip Chart Recorder 76<br />
Stroboscopes 78-79<br />
Surface Roughness 91<br />
Surge Generator 36<br />
Surge Transient Generator<br />
EMC/EMI Test 21<br />
Survey Equipment 78<br />
Sweep Generator 13<br />
t<br />
Tachometers 78-79<br />
Tape Recorders 76<br />
TDR 36-37<br />
Telecommunications<br />
BERT 28<br />
CDMA 23<br />
Communications Analyser 28<br />
Fibre Optics 33-34<br />
GSM 28<br />
ISDN 28<br />
PDH 28<br />
POTS 28<br />
SDH 28<br />
Signalling Analyser 28<br />
System Tools 28<br />
WAN analyser 31<br />
W-CDMA 23<br />
Temperature<br />
IR Thermometer 102-103<br />
Logging 72-73, 130<br />
Recorders 102<br />
Thermocouple 102-103<br />
Thermometer 102-103<br />
Tension 85<br />
Thermal Imaging Camera 104-105<br />
Thermocouple 102-103<br />
Thermohygrograph 102<br />
Time Domain Reflector<br />
TDR 36-37<br />
Token Ring Analyser 30<br />
Torque Wrench 84<br />
Total Dissolved Solids (TDS) 129<br />
Toxic Gas Monitor 123, 125, 127<br />
Transducers<br />
Current 53, 60, 63<br />
Electrical 60, 62<br />
Frequency 60-63<br />
Humidity 77, 83-84<br />
Instrument Transformer 60, 62<br />
position 84<br />
pressure 77, 82-83<br />
Temperature 77, 83-84<br />
Voltage 60, 62-63<br />
Transformer Oil Test 46<br />
Transient Burst 21<br />
Transport<br />
Inclinometers 84<br />
Turbidity 128-130<br />
TV Test Equipment 27<br />
u<br />
Ultrafine particle Counter 113-114, 117<br />
Ultrasonic bath 100<br />
Uninterruptable power Supplies<br />
- UpS 66-67<br />
UV Exposure 119<br />
v<br />
V24, V35 31<br />
Valve balancing (Air Conditioning) 118<br />
Vane Anemometer 113-115<br />
Variacs 67<br />
VCR 82, 106<br />
Vibration<br />
Accelerometer 88-89<br />
Analyser 88-89<br />
Blast Logging 90<br />
Impact Hammer 89<br />
Logging 89-90<br />
Table 88, 90<br />
Transport Testing 89<br />
Whole Body 88<br />
Video<br />
Endoscope 81<br />
High Speed 82<br />
Microscope 82<br />
pipeline Inspection 79-81<br />
Video Camera<br />
Digital 106<br />
VHS 82, 106<br />
Video Security 106<br />
Viscometer 86, 131<br />
VLF MV Cable Test 59<br />
Volatile Organic Compounds<br />
(VOC) 123, 127<br />
Voltage Calibrator 94-95<br />
Voltage Transducer 60, 62<br />
Voltmeter 6, 22<br />
W<br />
Walk Through Metal Detector 106<br />
WAN Analysers 29-31<br />
Water<br />
Analysis 130<br />
Conductivity 129<br />
Depth 110-111, 129-130<br />
Flow 110-111<br />
Leakage Detection 37<br />
pH 128-129<br />
Quality 128-129<br />
Sampling 130<br />
Water/Oil bath Temp Calibrator 94-95, 97<br />
Waveform Generator 8<br />
WbGT 113-114, 117<br />
Weather 118<br />
Wind Speed & Direction 117-118<br />
Workplace Safety<br />
See Occupational Health & Safety<br />
x<br />
x.21, x.24 30-31<br />
x-Ray Measurement 19-20
YOUR <strong>TR</strong>USTED PARTNER IN TECHNOLOGY<br />
OFFERING INNOVATIVE <strong>SOLUTIONS</strong> THROUGH<br />
OUR LEADING BRANDS:
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my<br />
YOUR <strong>TR</strong>USTED PARTNER IN TECHNOLOGY.<br />
OFFERING INNOVATIVE <strong>SOLUTIONS</strong> THROUGH OUR<br />
LEADING BRANDS: