The panel is fitted with 3 x Oxygen analysers complete with High/Low alarms, for monitoringeach diver’s gas supply.The depth gauges are 0- 100 metres(330 feet). The panel is fitted with HP/LPregulators for the control of the mixedgases and HP air. The panel is built intoan aluminium frame for wall mountinginside a dive control space.The panel is supplied fully certified,calibrated and complete with supportingdocumentation.Standard Panel Connections are as follows:Inlets:Outlets:HP 1/4" NPT Male, LP 3/8" NPT MaleDivers Supply 3/8" NPT Male, Divers Pneumo 1/4" NPT MaleOther connections are available to suit individual Client’s requirements but are subject toseparate quotation.OPTION 3Standard ISO Container 10ft x 8ft Wet Bell Dive Control ContainerThe Dive Control container isoutfitted with a steel floor and isdivided into two sections;designated Dive Control Section andUmbilical Storage Section. Bothsections can be accessed via thecontainer main double doors and afurther separate personnel door tothe dive control section in thedividing bulkhead, which isadditionally fitted with a largeobservation window.


The Dive Control section is fully Air Conditioned complete with full thermal insulation to thebulkhead walls and ceiling. The dive control section is outfitted with an incoming Air/Gassupply penetrator plate hard piped in Tungum or SS to the 3 diver mixed gas panel.The outgoing supplies to each diver fromthe 3 diver panel are hard piped via adedicated umbilical connection penetratorplate. A single phase 240 Volt electricalsupply is provided to the internaldistribution panel via an externallymounted bulkhead plug suitably rated forservice. The container is illuminated withoverhead fluorescent lights withemergency backup lighting.The storage section of the container isequipped with 3 x Stainless Steel umbilicalhangers for safe storage of the umbilicalswhen they are not in use.LARS OPTIONSHydraulic ‘A’ Frame ModelHydraulic Power Unit 30 kWPart Nos.SMP000714SMP0009943 Diver Mixed Gas Panel DDBC.S000310 Ft Dive Control Container TBA on Spec

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!