<strong>MDA</strong> <strong>Scientific</strong> Midas ® <strong>Gas</strong> monitoring system for fast andreliable detection of flammableand toxic gases used in industrialmanufacturing processes


Midas ®Features:• Over 40 gases available with extended 2year warranty*• Smart sensor cartridge with on board‘e-calibration’ certificate• 3 built in relays (Form C) for Alarm 1, 2and Fault• Power over Ethernet (PoE) communicationand power platform• Keypad Interface and remote Web BrowserInterface• Pyrolyzer and LonWorks ® interface optionalmodules that connect to any transmitter• Password protected menu levels topreserve system integrity• Bright LEDs and intuitive Icon Driven, largebacklit LCD display• Factory-calibrated sensors to reduce needfor frequent gas testing• Isolated 0-22 mA Analog Output with faultand event reporting• Modbus/TCP Ethernet for easy connectivityto all control and alarm systems ports forcontrol connectivity and service interaction• Robust extractive pump system (2 yearlifetime) sampling up to 30m• Interactive Training Simulator tool• CE marked for total immunity to RadioFrequency Interference• Reflex ® sensor health check for improvedsafety• TempraSure TM temperature compensationtechnology as appropriate• Event logging to review sensor history• Patented reporting technology confirmslikely gas release to avoid nuisance alarms(* standard 1 year warranty)Midas ® is a gas monitoring system forfast and reliable response to the presenceof virtually all of the gases used orgenerated in the Semiconductor and otherindustrial manufacturing applications.Midas ® offers lower cost of ownershipbenefits for gas detection through acombination of extended sensor calibrationperiods, flexible communicationsarchitecture and patented diagnostics thatmonitor sensor performance and flow control.Midas ® is a universal transmitter platform that detectsthe majority of toxic, ambient and flammable gasesthat must be monitored in a typical industrial processenvironment. The pre-calibrated ‘plug-and-play’ smartsensor cartridge makes sensor replacement quick andeasy to manage with no tools required, and preventsany operator error associated with using incorrect ordepleted sensors. Bright LED lights and an intuitive,icon driven interactive menu guarantee instant alert tothe gas reading or alarm level coupled with passwordprotected menus for configuration, test and calibration.Midas ® is very compact in size and it’s easy accessmetal chassis design makes it simple to install incrowded, increasingly complex process environmentsor retro fit applications where space is at a premium.Midas ® has flexible power and communications built inas standard including 3 on-board relays, 0 - 22mAanalog output, Modbus/ TCP Ethernet digital outputs,as well as the innovative Power over Ethernet (PoE)protocol - a single Ethernet connection for all power,control and communication requirements. Costeffective integration with PLC and FieldBus systems isgreatly simplified with the Midas ® architecture.Midas ® will monitor points up to 30m (100 feet) awayfrom the transmitter and flow rates are regulatedautomatically using patented control technology toensure error free gas sensing operation. HoneywellAnalytics designs and manufactures its own sensorsusing advanced robotics to ensure unbeatable qualityand reliability.Midas ® is complimented by the innovativeChemcassette ® range of ultra sensitive low ppb toxicgas detection analyzers and our worldwide network ofservice engineers who operate on a 24/7 basis.


????????? ????????? ?????????? ??? ? ??????????????Installation DetailsMechanicalRemoving coverRefitting chassisaligning connectorand tubingchassisloosenconnectorPCBcovermountingbracket1screwspipes4chassisHow cartridge is fittedchassisRemoving chassis??? ?? ?? ??? ? ?????? ? ? ??? ? ? ? ?? ? ? ?? ?? ?cartridgemountingbracket25Attaching bracket toscrews on a wallHow cover is fittedmountingbrackettightenscrews3??? ?? ?? ????? ?????????????????? ?? ?? ????? ??? ?? ?slots6cartridge fittedtabs


General SpecificationsElectricalAll wiring permutations shown for example purposesAll wiring permutations shown for example purposes63mmAnalog Output0-22mAEdge connectorto Pyrolyzeror Analog InputModule120mm3 RelaysTerminals forAlarm1, Alarm 2,Fault relays24V DC – if requiredPower On/Off SwitchEthernet port(RJ45)Gland Fittingfor DC power,analog, relaysRJ45 CATEthernet Connectorfor Power and/or Modbus TCPEthernet – if requiredSample InletSample OutletCable Gland- PG16Detectable <strong>Gas</strong>es<strong>Gas</strong> Name Chemical Formula Range Sensor Part NumberAmmonia NH 30 - 100 ppm MIDAS-S-NH3Arsine AsH 30 - 0.2 ppm MIDAS-S-ASHBoron Trichloride BCl 30 - 8.0 ppm MIDAS-S-HCLBoron Trifluoride BF 30 - 8.0 ppm MIDAS-S-HFXBoron Trifluoride (Low Level) BF 30 - 2.0 ppm MIDAS-S-HFLBromine Br 20 - 0.4 ppm MIDAS-S-BR2Carbon Dioxide CO 20 - 2.0 % vol MIDAS-S-CO2Carbon Monoxide CO 0 - 100 ppm MIDAS-S-COXChlorine Cl 20 - 2.0 ppm MIDAS-S-HALChlorine Dioxide ClO 20 - 0.4 ppm MIDAS-S-BR2Chlorine Trifluoride ClF 30 - 0.4 ppm MIDAS-S-SF4Diborane B 2H 60 - 0.4 ppm MIDAS-S-HYDDichlorosilane H 2SiCl 20 - 8.0 ppm MIDAS-S-HCLDifluoromethane CH 2F 20 - 120 ppm MIDAS-S-CFXDisilane Si 2H 60 - 20 ppm MIDAS-S-SHXFluorine F 20 - 4.0 ppm MIDAS-S-HALGermane GeH 40 - 0.8 ppm MIDAS-S-HYDHexafluorobutadiene C 4F 60 - 40 ppm MIDAS-S-CFXHydrogen (% LEL)* H 20 - 100% LEL MIDAS-S-LELHydrogen (ppm) H 20 - 1000 ppm MIDAS-S-H2XHydrogen Bromide HBr 0 - 8.0 ppm MIDAS-S-HCLHydrogen Chloride HCl 0 - 8.0 ppm MIDAS-S-HCLHydrogen Cyanide HCN 0 - 20 ppm MIDAS-S-HCNHydrogen Fluoride HF 0 - 12 ppm MIDAS-S-HFXHydrogen Fluoride (Low Level) HF 0 - 2.0 ppm MIDAS-S-HFLHydrogen Selenide H 2Se 0 - 0.4 ppm MIDAS-S-HSEHydrogen Sulfide H 2S 0 - 40 ppm MIDAS-S-H2SHydrogen Sulfide (High Level) H 2S 0 - 100ppm MIDAS-S-HSHMethane (% LEL)* CH 40 - 100% LEL MIDAS-S-LELMethyl Fluoride CH 3F 0 - 60 ppm MIDAS-S-CFXNitrogen Dioxide NO 20 -12 ppm MIDAS-S-NO2Nitrogen Oxide NO 0 - 100 ppm MIDAS-S-NOXNitrogen Trifluoride NF 30 - 40 ppm MIDAS-S-HFXOctofluorocyclopentene C 5F 80 - 40 ppm MIDAS-S-CFXOxygen Proficiency & Deficiency O 20 - 25% vol MIDAS-S-O2XOzone O 30 - 0.4 ppm MIDAS-S-O3XPhosphine PH 30 - 1.2 ppm MIDAS-S-PH3Phosphorous Oxychloride POCl 30 - 0.4 ppm MIDAS-S-POCSilane SiH 40 - 20 ppm MIDAS-S-SHXSilane (low level) SiH 40 - 2.0 ppm MIDAS-S-SHLSulfur Dioxide SO 20 - 8.0 ppm MIDAS-S-SO2Sulfur Hexafluoride SF 60 - 8000 ppm MIDAS-S-CFXSulfur Tetrafluoride SF 40 - 0.4 ppm MIDAS-S-SF4Tetra Ethyl Ortho Silicate TEOS 0 - 40 ppm MIDAS-S-TEOTungsten Hexafluoride WF 60 - 12 ppm MIDAS-S-HFXTungsten Hexafluoride (Low Level) WF 60 - 2.0 ppm MIDAS-S-HFLFor standard 1 year sensor warranty use theorder part number format MIDAS-S-XXX; forextended 2 year warranty use the formatMIDAS-E-XXX* Midas ® detectors are not ETL approvedfor monitoring in or sampling from classifiedareas above 25% LELOxygen detection products must only be used to detect oxygen depletion in air


Technical SummaryTransmitter DimensionSampling DistanceSize (unit with Sensor)Weight (unit with Sensor)120mm (H) x 63mm (W) x 150mm (D)0.8kgTubing LengthAmbient Point <strong>Monitoring</strong>Up to 30m (100 feet) with FEP tubing dependanton gasIn line air filter recommendedPyrolyzer Dimensions (Regular and High Temperature versions)Exhaust LengthUp to 30m (100 feet)Size (MIDAS-T-00P)Weight (MIDAS-T-00P)Size (MIDAS-T-HTP)Weight (MIDAS-T-HTP)70mm (H) x 63mm (W) x 83mm (D)0.41Kg113mm (H) x 101mm (W) x 140mm (D)1.25KgTubing RequirementSampleExhaust6.35mm OD (1/4") x 3.18mm (1/8"), FEP,30m (100 feet) maximum dependant on gas type6.35mm (1/4") OD x 4.76mm (3/16"), FEP,30m (100 feet)Power RequirementsOperating Voltage 24V DC Nominal +/- 10%Operating TemperatureOperating Voltage withPower over Ethernet (PoE)36 - 57 VDC via PoE, 48V DC NominalUnit with Sensor0°C (32°F) to 40°C (104°F)Wiring RequirementPower ConsumptionTransmitter UnitWith Pyrolyzer (Option)~ 5.0 W< 12.95 W4-20mA/DC Power/RelaysDigital14 AWG MaximumShielded CAT 5 cable or equivalent, RJ45 connectorOutputsVisualAlarm, Power and Fault lights as well as back litLCD display with all gas readings and events<strong>Gas</strong> Concentration Display & InterfaceInstrument4-digit alphanumeric display with separatemeasurement units, flow rate bar graph and othericon driven indicators. 4 button membrane keypadRelays 3 relays for Alarm1, Alarm 2 and Fault rated 1.0A@ 30VDC or 0.5A @125VAC;configurable NO or NC, latched or unlatchedRemote InterfacePC / PDA Internet Browser access via Ethernet orother Bus systemAnalog2 wire isolated, 0 - 22mA, Sink or SourceWarrantyDigital CommunicationsService PortStandard: Modbus / TCP Ethernet / Power overEthernet (PoE). Option: LonWorks ®RS232C / PPP protocolTransmitter UnitSensor Cartridge1 year1 year standard; 2 year with extendedwarranty programCertification & SpecificationExpected Lifetime of Pump> 2 yearsEuropeanEnvironmentalCE marked; meets EN 50270:1999 (Type2)and EN 55011:2000ETL approved UL 61010B and CSA-C22.2No. 1010.1-92Performance Designed to meet with UL 2075 (pending 2004)Installation DetailsMountingMaterialWall mounted using 2 pre-drilled holes onrear chassisSteel case with paint finishElectricalIEEE 802.3af-2003Response TimesFlow Rate500 mL/minTransport Time2 - 30 seconds maximumOrdering InformationPerformanceLDL < LALUNITTransmitterPART NUMBERMIDAS-T-001LAL = ½TLV (typically 12% FSD)Pyrolyzer (NF 3)MIDAS-T-00PFSD = 4 x TLVPyrolyzer (High Temperature)MIDAS-T-HTPLonWorks ® InterfaceMIDAS-T-LON


<strong>MDA</strong> <strong>Scientific</strong> has developed a sophisticated range of highlysensitive gas detection equipment, designed to perform in waysthat define new gas detection performance levels providing totalsolutions to protect people, improve production efficiency andreduce costs.The <strong>MDA</strong> <strong>Scientific</strong> range of toxic gas detectionSingle PointMonitorVertexModel IR-148Midas ®CM4The SPM overcomes thedifficulty of ensuring thatbasic units for toxic gasmonitoring are accurate andfree of interference fromenvironmental conditionsor other chemicals, byusing our interference-freeChemcassette ® detectiontechnique. The SPM can alsobe used outdoors and hasheating and cooling options tosuit environmental conditions.Vertex provides a flexible,cost-effective monitoringsolution that can adaptto changing needs. Usingadvanced Chemcassette ®software and opticstechnologies, Vertex canmonitor from 8 to 72 pointsof gas detection, up to 9 gasfamilies and more than40 gases.The Model IR-148 detectssolvents and gases suchas HCFCs, HFCs and PFCsthat are otherwise difficult tomonitor without the effect ofcross-interfering gases.Midas ® can measure virtuallyall the toxic and flammablegases found in manufacturingand storage applications.The range is in fact auniversal transmitter designthat differs significantly fromthe Lifeline II range which hadseparate passive, extractiveand pyrolyzer variants withdifferent footprints andperformance characteristics.CM4 provides monitoring oftoxic gases at four locations,up to 300 feet away– detection of ppb levelsof toxic gases at multiplepoints. Points are monitoredcontinuously. Leaks aredetected within seconds.Find out morewww.honeywellanalytics.comIN-USAChemcassette ®Customer business centreEurope and the rest of the worldHoneywell Analytics AGWilstrasse 11-U11CH-8610 UsterSwitzerlandTel: +41 (0)44 943 4300Fax: +41 (0)44 943 4398sales@zelana.co.ukThe IN-USA range ofmicroprocessor controlledanalyzers detect traceamounts of ozone (O 3) gas.<strong>System</strong>s can be configuredwith relays and differentsignal output options forintegration within life safetynetworks. High levels of signalsensitivity and resistance tofalse alarm are enabled by theuse of advanced ultraviolet(UV) lamp detection systems.The Chemcassette ® detection system is the heart of an <strong>MDA</strong> toxicgas monitoring system. Chemcassettes ® use a dry reagent medium tocollect and analyze air to detect gas leaks. When the Chemcassette ®is exposed to a target gas, it changes color in direct proportion tothe concentration of gas present. <strong>MDA</strong> <strong>Scientific</strong> monitors read colorintensity changes and determine the gas concentration by comparisonto a known gas response pre-programmed into the instrument.Customer business centerAmericasHoneywell Analytics Distribution, Inc.400 Sawgrass Corporate PkwySuite 100Sunrise, FL 33325USATel: +1 954 514 2700Toll free: +1 800 538 0363Fax: +1 954 514 2784sales@zelana.comwww.honeywell.comPlease Note:While every effort has been made to ensureaccuracy in this publication, no responsibilitycan be accepted for errors or omissions.Data may change, as well as legislation, and youare strongly advised to obtain copies of the mostrecently issued regulations, standards, and guidelines.This publication is not intended to form thebasis of a contract.© 2005 Honeywell AnalyticsH_Midas_DS_V112/05© 2005 Honeywell Analytics11095