PRODUCT INFORMATIONPROCESS ANALYSISELECTROCHEMICAL SENSOR<strong>ORBISPHERE</strong> <strong>313XX</strong>Cable connectorO 3Attachment collarProtection capStorage &calibration cap<strong>ORBISPHERE</strong> <strong>313XX</strong> <strong>sensor</strong>:<strong>The</strong> <strong>best</strong> <strong>in</strong> O 3 <strong>sensor</strong>s➔ Measures down to 5 ppbassur<strong>in</strong>g residual accuracylevel➔ Quick and easy traceableair calibration➔ Guard r<strong>in</strong>g electrode givesfaster responses andreduces <strong>in</strong>terferences➔ Installs <strong>in</strong>-l<strong>in</strong>e for processcontrol and <strong>in</strong> flowchamber for samplesdrawn off-l<strong>in</strong>eFast and accurate measurements<strong>The</strong> <strong>ORBISPHERE</strong> <strong>313XX</strong>electrochemical O 3 <strong>sensor</strong> has apolarographic patent and is designedto be a proven performer whereknowledge of O 3 content is critical.From potable water treatment topharmaceutical and semiconductormanufactur<strong>in</strong>g, this <strong>sensor</strong> providesfast, accurate measurements <strong>in</strong> liquidand gaseous samples.Pr<strong>in</strong>cipleThis <strong>sensor</strong> is constructed of twometal electrodes, the noble work<strong>in</strong>gelectrode and a counter electrode. Itis immersed <strong>in</strong> an electrolyte solution,and separated by a gas permeablemembrane from the sample of <strong>in</strong>terest.An auxiliary guard r<strong>in</strong>g electrodesurrounds the work<strong>in</strong>g electrode toshield aga<strong>in</strong>st other gases and improvestability.


<strong>ORBISPHERE</strong> <strong>313XX</strong>_TECHNICAL DATATechnical dataImproved accuracyElectrical potential is applied betweenthe electrodes to reduce ozonedriven through the membrane by apartial pressure gradient. An electricalcurrent results, that is proportional<strong>in</strong> magnitude to the concentrationof <strong>in</strong>terest. This is measured by the<strong>in</strong>dicat<strong>in</strong>g <strong>in</strong>strument, scaled, displayedand converted to analogue and digitaloutputs.<strong>The</strong> <strong>ORBISPHERE</strong> <strong>313XX</strong> can measureozone <strong>in</strong> a wide range of temperaturesand pressures. This is because ofits exclusive valve seat<strong>in</strong>g, wherethe <strong>sensor</strong> cathode is mechanicallytensioned aga<strong>in</strong>st a ceramic valve seatto ensure the <strong>in</strong>tegrity of the seal. Thisdesign produces a small residual signalfor improved accuracy.All <strong>ORBISPHERE</strong> ozone <strong>sensor</strong>s usethe deep-draw membrane mount<strong>in</strong>gmethod.This provides a uniformly th<strong>in</strong>layer of electrolyte, faster responseand superior stability. Coupled with ascrew-on protection cap, the <strong>sensor</strong>allows <strong>in</strong>-service <strong>in</strong>tervals for up to ayear. <strong>ORBISPHERE</strong> <strong>sensor</strong>s can becalibrated <strong>in</strong> air for ease of use andaga<strong>in</strong>st a sample of known ozonecontent.SampleAnodeElectrolyteSensor headMembraneCathodeGuard r<strong>in</strong>gApplication dependant membrane / Sensor specificationMembrane model 2956A 29552AMaterial PFA PTFEThickness 25 µm 50 µmDissolved O 3 measurement range 0 ppb–50 ppm 0 ppb–200 ppmGaseous O 3 measurement range 0 Pa–10 kPa 0 Pa–40 kPaAccuracydirect calibration: ±1% or ± 5ppb ±1% or ± 20ppb, whichever is greaterair calibration: ±5% or ± 5ppb ±5% or ± 20ppb, whichever is greaterRepeatability±1% (<strong>in</strong>dependent of calibration method)Lowest detection limit ±5 ppb ±20 ppbTemp. compensated range -5 to 45°C -5 to 45°CResponse time 30 sec. 6 m<strong>in</strong>.Recommended liquid flow rate*, ml per m<strong>in</strong>.,350 ml 100 ml<strong>in</strong> 32001 flow chamberRecommended l<strong>in</strong>ear liquid flow rate* cm/sec. 30 10Recommended gaseous flow rate 0.01 to 3 l/m<strong>in</strong>. 0.01 to 3 l/m<strong>in</strong>.Sensor modelStandard materials of constructionPressure rat<strong>in</strong>g Weight Recommended <strong>in</strong>dicat<strong>in</strong>g <strong>in</strong>strumentHead**/Body***(bar)(grams)31311 PEEK / Delr<strong>in</strong> 20 200 <strong>ORBISPHERE</strong> 26505 (ROS)31331 Titanium / Sta<strong>in</strong>less steel 100 640 <strong>ORBISPHERE</strong> 26506 (ROS)31330 Titanium / Sta<strong>in</strong>less steel 100 640 <strong>ORBISPHERE</strong> 410 / 51031330E Titanium / Sta<strong>in</strong>less steel 100 640 <strong>ORBISPHERE</strong> 366X EX31330S Titanium / Sta<strong>in</strong>less steel 100 640 <strong>ORBISPHERE</strong> 410 / 510* Flow rates for Model 32001 flow chamber are valid for <strong>sensor</strong>s used with a Model 29104 protection cap and without a sta<strong>in</strong>less steel grill. Use ofthe grill <strong>in</strong> protection cap model 29106 will require approximately 50% faster flow. / **Parts <strong>in</strong> contact with the sample: O-r<strong>in</strong>gs available <strong>in</strong> Viton orKalrez. / *** O-r<strong>in</strong>gs are <strong>in</strong> EPDM.Ask your local <strong>HACH</strong> <strong>LANGE</strong> representative for more details on all available spare parts and accessories. This data is subject to change without notice.DOC063.52.30038.Mar10<strong>HACH</strong> <strong>LANGE</strong> MAROC SARLAUVilla 14 – Rue 2 Casa PlaisanceQuartier Rac<strong>in</strong>e ExtensionMA-Casablanca 20000Tél. +212 (0)522 97 95 75Fax +212 (0)522 36 89 34<strong>in</strong>fo-maroc@hach-lange.comwww.hach-lange.maTél. +212 (0)522 97 95 75

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!