12.07.2015 Views

The Future of Energy…Now

The Future of Energy…Now

The Future of Energy…Now

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cleaner, Smarter, More Efficient<strong>The</strong> <strong>Future</strong> <strong>of</strong> Energy…NowGE Measurement & Control Business OverviewNovember 29, 201111/20/2012


THE GENERAL ELECTRIC COMPANY125+ years• 290,000 global employees • 2010 revenue $150BEnergyTechnologyGE CapitalHome/Business• Power & Water• Oil & Gas• Energy Services•Aviation• Healthcare• Transportation• Energy•Aviation•CommRealEstate• Commercial• GE Money• Appliances• Lighting• IntelligentPlatforms21/20/2012


GE ENERGYEmployees: 66,000 • ‘10 revenue: $37.5B • Operating in 150 countriesEnergy ServicesPower & WaterOil & Gas• Contractual agreements• Smart Grid• Field services• Parts and repairs• Optimizationtechnologies• Plant management• Power generation• Renewable energy• Gas engines• Nuclear• Gasification• Water treatment andprocess chemicals• Drilling/production• LNG and pipelines• Refining/petrochemical• Industrial power gen• Complete lifecycleservices31/20/2012


ENERGY SERVICES~ 27,000 employees ~ 180 locations2009 revenue ~ $13.8BEnvironmentalServicesDigitalEnergyMeasurement & Control~$2B Rev7,000 employees60 countriesPowerGenerationServicesIndustrialSolutions41/20/2012


MC – 30 AQUISITIONSBently NevadaReuter StokesWoodwardGlobal ServicesPressurementsMergedSensing & Inspection andOptimization & ControlT H E R M O M E T R IC SGlobal BusinessA C O M M I T M E N T T O E X C E L LE N C ENovasensorDaewoo Korea JVTecnatom S.A. IPSontayPana NDTSpaceLG Korea JVXinHua Controls2001 2002 2003 2004 2005 2006200720082010For internal use only51/20/2012


MC PRODUCT LINES2010$2B RevAdvanced SensorsMeasurement SolutionsInspection Technologies• Temperature• Pressure (MEMS)• Infrared• ValidationBently Nevada• Flow• Gas and Moisture• PressureControlSolutions• Ultrasonic, Eddy current• Remote Visual• CR/DR, X-Ray, CT• S<strong>of</strong>twareReuter Stokes• Monitors• Field devices• Tech support• System 1 ® s<strong>of</strong>tware• Machinery diagnostics• Retr<strong>of</strong>its and parts• EX2100• Mark IV, V, VI, VIe• OC 4000 DCS• S<strong>of</strong>tware upgrades• Nuclear instrumentation• Flame detectors• He-3 detectors• Scintillations sensors• Mechanical assemblies


ADVANCED SENSORSTemperaturePressure(MEMS)Moisture &Gas(commercial)Validation•NTC & PTC<strong>The</strong>rmistors• TemperatureSensors• Infrared <strong>The</strong>rmopiles• Qualification Testingand Calibration•Custom DesignCapabilities• Worldwide On-siteFabrication• Research &Development• Design, modelingand Fabrication• AdvancedPrototyping• PackageDevelopment• Device Integration• Hand-heldMoisture andHumidity Meters• CO 2Sensors andTransmitters• Hand-held CO 2and TemperatureMeter• CO 2Modules forOEMs• <strong>The</strong>rmal ProcessingValidation• Wireless ProcessValidation• EnvironmentalMonitoring• Turbine Test CellMonitoring• CalibrationLaboratories71/20/2012


INDUSTRIES WE SERVE….HealthcareTransportationIndustrial&BuildingsPharmaSampleApplications• Sleep Apnea• <strong>The</strong>rmometry• Neonatal• Critical Care• Anesthesia• Blood pressure• Climate Control• EMS (Enginemanagementsystems)• Tire Pressuremonitoring• OccupancyDetection• Indoor Air qualitymonitoring• CO2-basedventilation control• Aerospace• White Goods• Home flood damage• Cleaning• <strong>The</strong>rmal• Facilitymonitoring• ProcessAnalyticalTechnologies(PAT)EnablingTechnology• MEMS pressure• Temperature• Catheterthermistors• MEMS IR• NTC/PTC <strong>The</strong>rmistorassemblies• MEMS NPP & NPX• MEMS IR• Temperature• Humidity• MEMS Die / IR• Wireless• Validator• Valprobe• Lab Watch• Calibration81/20/2012


GE ADVANCED SENSOR SITESSt Marys,PABillerica, MATaunton,UKGroby,UKFremont, CATijuana,MexicoPuertoRicoPyong Taek,KoreaChangzhou,ChinaAyutthaya,ThailandPositioned globally – resourced locally91/20/2012


QUALITY ASSURANCE• GE manufacturing facilities hold a variety <strong>of</strong>laboratory accreditations and certificates <strong>of</strong>approval for quality management systems inNorth America, Europe, and Asia.ISO 13485 - MedicalISO 9001 – ManufacturingISO 14001 - EnvironmentalISO/TS 16949 – AutomotiveQS 9000 – Automotive101/20/2012


GLOBAL RESEARCH CENTERSGlobal Research CenterNiskayuna, NYJohn F. Welch Technology CenterBangalore, IndiaChina Technology CenterShanghai, ChinaGlobal Research – EuropeMunich, Germany• 2,600 researchemployees (nearly1,000 PhDs)• 27,000 GEtechnologistsworldwide• $5.7 billiontechnology spend111/20/2012


HEALTHCARE APPLICATIONSPatient monitoring• Non-contact Infra-red sensors• <strong>The</strong>rmometer sensors• Skin temperature assemblies• Rectal temperature• Intra-uterine pressureRespiratory & sleep apnea• Calibrated pressure sensors• Humidity sensors• Flow sensors• Temperature sensors• Integrated sensor assembliesDrug delivery• Pressure sensors• Temperature sensors• MEMS valves• Flow controlCritical care• Catheter pressure• Temperature Sensors & assemblies• Surgical temperature assemblies• Ablation sensorsMedical Equipment• Pressure, Temperatureand humidity sensors121/20/2012


Pressure Sensors……..for Healthcare


MEMS PRODUCTHealthcare strategyYesterday Today Evolving<strong>Future</strong>ManualAutomatedContinuousValue Proposition:GE works with its customers toimprove patient outcomes throughadvanced technologies for medicaldevices by pairing industryexpertise in sensor and microsystemdesign with in depthcustomer knowledge to deliver thebest solutions for respiratory, drugdelivery and critical care treatment.RespiratorySensor IntelligenceDrug Delivery Critical Care & Patient MonitoringGE Advanced Sensors Offerings


MEMS – HEALTHCARE PRODUCTSBloodPressureNPC-100DisposableNPP-301Cuff BPCustomAssembliesCatheterPressureCatheter die1 F & 3 FDieCatheterPressureAssembliesRespiratoryApplicationsNPC-126010” H2O or 1psiNPC-121010” H2O to 100 psiDigital Packages NPAAmplified, 10”H2O - 30psi151/20/2012


MEMSPressureNPC-100Disposable Blood Pressure TransducerFeaturesApplicationsSolid State, High ReliabilityMedia Compatibility, Factory filled withdielectric gelHigh Performance, Small sizeFully Tested, Temperature testedLow Cost Disposable DesignDesigned to AAMI (BP-22) specificationsMedical InstrumentationsBlood Pressure MeasurementsInfusion PumpsKidney Dialysis Machines161/20/2012


MEMSPressureCHIPS“Ceramic Hybrid Integrated Pressure Sensor”NPC 1200 Series• PCB mountable DIP package• Temp Compensated from 0-70°C• Absolute, gage, or differential• Pressure range: 10” H 2O to 100 psiNPC 1200 seriesAPPLICATIONS• Respiratory & sleep apnea• Process control• Non-invasive blood pressureSmart, versatile pressure sensing to meet stringent design standards171/20/2012


NPA Series Pressure SensorsMEMSPressureProduct / DescriptionGE’s NPA series pressure sensors combine ourSenStable ® silicon fusion bonded sensor die withpackaged electronics to provide a highly stable,amplified and calibrated measurement in a costeffective surface mount package.ManifoldGauge/AbsoluteBarbed FittingGauge/Absolute/DiffBenefitsNo FittingGauge/Absolute/Diff Analog, Amplified analog or Digital output options Temperature measurement available with digital output Temperature compensated from 0°C to 70°C Flexible pressure ranges Large overpressure capabilities Excellent long term stability (SenStable ® technology) Accuracy: Better than 1.5% full scale output Surface mount SOIC-14 packagePressure ranges:Preliminary Specifications0 to 10” H 2 O up to 30 psiTemp compensation: 0°C to 70°COperating temp: -40 o C to 125 o CAccuracy:±1.5% full scale outputPressure overload: 60x @ 5psiFSODigital output:14 bitDigital power supply: 5Vdc standard (3 to 5Vdcoptional)Analog power options: 3.3Vdc supply 0.5-3.0Vdc output5.0Vdc supply 0.5-4.5VdcoutputConfigurability5.0Vdc or 1.5mA 100mV output(typ) Optional pressure port configurations give2.7 to 5.5Vdc 0-1Vdc outputsuperior design flexibility Gage, differential or absolute pressure options Multiple power supply and output voltage options Extended temperature compensation ranges canbe accommodatedSmart, versatile pressure sensing to meet stringent design standards181/20/2012


Medical Catheter Pressure SensorsMEMSPressureProduct DescriptionGE Sensing’s Catheter Pressure sensors arefast response, ultra-stable and accuratepiezo-electric MEMS based devicesspecifically designed to provide excellentpressure measurement within the very smallspace and harsh environments <strong>of</strong> catheterapplications.Technical Specifications• Pressure Range -50 to 300 mmHg• Operating Temp 10°C to 50°C• Excitation1 to 8 Volts AC or DC• Zero Offset±12.5 mV/V• Sensitivity12 to 24 μV/V/mmHg• Linearity±1mmHg• TcZ±40 μV/V/°C• Bridge Resistance 800 ±20% Ohms• Burst Pressure4000 mmHgNPM-100P161Benefits Real time (beat-by-beat) pressuremonitoring Very small, fits standard catheter sizes Fast response optimized for catheters Stable accurate pressure measurement AC or DC excitation Gage (P161) and Absolute (P165) dieversions Custom sub-assemblies with temp optionTypical Applications Intracranial Intrauterine Disposable catheters Urinary catheters Ablation ResearchFast Response, Accurate & Stable Pressure MeasurementExcellent for minimally invasive applications where small size is191/20/2012


Product ConfigurationsNPM-100G-XL: 6F Catheter Tip Pressure, Gage(Leads Optional: 2, 4 or 6 foot)NPM-050A/G-XL: 6F Die on Carrier, Absolute or Gage(Leads Optional: 2, 4 or 6 foot)Note: Units in mm201/20/2012


P330 Medical Pressure DieMEMSPressureProduct DescriptionGE Sensing’s Catheter Pressure sensors arefast response, ultra-stable and accuratepiezoresistive MEMS based devicesspecifically designed to provide excellentpressure measurement within the very smallspaces and harsh environments <strong>of</strong> catheterapplications.P330 DieBenefits Real time (beat-by-beat) pressuremonitoring Very small, fits standard catheter sizes Low power consumption Fast response optimized for catheters Stable accurate pressure measurement Gauge and Absolute die versions High volume OEM quantities availableTechnical Specifications• Pressure Range -710 to 1600 mmHg A @ 1atm• Operating Temp 10°C to 50°C• Excitation1 to 5 Volts DC• Zero Offset±12.5 mV/V• Sensitivity5 to 25 μV/V/mmHg• Linearity (TBNL) ±1.5 mmHg• TCZ±40 μV/V/°C• Bridge Resistance 3K ± 1K Ohms• TCR0.04+/-0.02 %/ o C• Burst Pressure 3000 mmHg• 330 x 180 micron cross section (width x height)Targeted Catheter Applications Intracranial Intrauterine Urinary Ablation Catheter Navigation ResearchFast Response, Accurate & Stable Pressure MeasurementExcellent for invasive applications where small size is


Pressure Sensors DieSizes range from 0.3 mm to 3.2 mmPressure ranges from 10” H 2 O to5000 psi (35K kPa)221/20/2012


Silicon MEMS FabricationLithography• Steppers, contact aligners• Double Sided Lithography• Thick resistThin Film Deposition• Standard: Oxide, LTO, Nitride, Poly, Al• Special: Au, SiCr, Ta, Ni, Cr, Pt….Etch• Standard IC wet etch benches• Electrochemical (KOH, TMAH, EDP)• Plasma, RIE and DRIEBonding• Aligned silicon fusion and anodic bonding• Selective and controlled medium3/4 million dice produced weeklyClass 100: 5500 sq ft (511 sq. m )Class 1000: 5500 sq ft (511 sq. m)231/20/2012


Temperature Sensors……..In Healthcare


TEMPERATURE – HEALTHCARE PRODUCTSCranial CatheterCatheter Tip Pressure DieOral TemperatureMA200 NTC Temp Assembly<strong>The</strong>rmal DilutionCatheter (Heart)AB6 Catheter AssemblyRF AblationAX <strong>The</strong>rmocouple assembliesFoley CatheterMA100 Temp AssemblyTympanic TemperatureZTP-135 IR Temp AssemblyEsophageal CatheterMA100 NTC Temp AssemblySkin TemperatureMA300 NTC Temp AssemblyKidney DialysisMEMS NPCGlucose MonitoringNTC Temp AssemblyRectal TemperatureMA100 NTC Temp AssemblyAnesthesiaBlood/Fluid HeatersHumidifiersOxygen TentsClinical MattressSleep Apnea251/20/2012


MEDICAL TEMPERATURE TARGETS+/- 0.05C37CBody Core+/- 0.220C - 45C+/- 0.1C34C - 39C261/20/2012


GE – THERMISTOR ELEMENT TYPESBeads Chips GC• .003” to .100” dia• stability up to 300°C• 5 ms response time• .020” to .100” dia• stability up to 105°C• Interchangeable to .05°Ctol• .011” to .055” dia.• stability up to 250°C• 12 ms Response time• Fast response, sizerestricted sensors• Sensors for extremetemp (-200K to 450°C)• Probe sub assemblies• High reliability/Milsensors• Flow, gas, liquid levelsensing• General purpose sensors• Medical disposableproducts• Probe sub assemblies• Fast response, sizerestricted sensors• Sensors for extremetemp (-200K to 450°C)• Probe sub assemblies• Medical disposables271/20/2012


Product DescriptionGE Sensing’s Catheter Temperaturesensors are NTC thermistors sealed inglass and packaged to provide very fastresponse time and excellent pointisolation <strong>of</strong> the temperature measurement.NTC beadelements inassembly tipBenefitsAB6 sensor assembly(on shipping spool) Small packages to fit standard lumens Very fast response time Excellent point isolation <strong>of</strong> measurement Insulated sub assembly with proven reliability Tight resistance–temperature (±0.5%)characteristics Various lead lengths available Extensive qualification & validation data availableMedical CatheterTemperature SensorsTechnical Specifications• Resistance at 37°C 14004 Ω ± 0.5%• Beta 3482 ± 5%• Ratio R(298°K)/R(310°K) 1.572 ±0.036• Time Constant (still air) 1.2 seconds• Time Constant (H 2 O) 16 mS• Sleeve Diameter 0.020” ± 0.002”• Sleeve Material Kapton (polyimide)• Max. Power Rating 15mW• Bead Dissipation:Still Air @ 25°C 0.12 mW/°CStill H 2 O @ 25°C 0.60 mW/°C* Contact GE Sensing for information on other catheter product specificationsTypical Applications Continuous Cardiac Output <strong>The</strong>rmodilution Foley Esophageal Disposable cathetersFast Accurate Temperature Measurement in a very small packageHealthcareTemperatureExcellent for catheter applications where fast response time iscritical281/20/2012


Precision Temperature Sensorsfor Surgical ProceduresProduct DescriptionTechnical SpecificationsHealthcareTemperatureMiniature, precision temperature sensors forsurgical and other medical procedures.Applications include Ablation procedures,Open heart surgery (Myocardium)temperature, Brain tissue pr<strong>of</strong>iling, Cancertreatment, IV fluid temperature, Cosmeticsurgery, etc.Designs are customer and applicationspecific utilizing flexible tubing, stainlesssteel probes, hypodermic needles, or otherfittings/fixtures.BenefitsMiniature NTC chip or glass bead thermistorsand fine wire thermocouples assembled intoinsertion probes, fittings, or tubing formeasuring and controlling temperature duringcritical procedures.• Temperature range: 0°C to 70°C (others available)• R-T curves: Standard curves available (400 series, etc.)• Accuracy & Interchangeability: down to ±0.05°C• Sizes: down to 0.005” diameter (NTC only)• Response times: down to < 10 milliseconds, H2O• Can be ETO, autoclaved, or e-beam sterilizedTypical Applications Extremely small size, fast responsetime Reliable performance Temperature accuracies to ±0.05C Designed for Sterilization Wide range <strong>of</strong> custom packaging Complete design support Interchangeable for single use (optional) Ablation exposure control Core temperature duringsurgery Cancer research andtreatment Cranial temperature Laser surgery Cosmetic surgery IV fluid temperatureImproving the success <strong>of</strong> patients outcomes throughreliable measurements291/20/2012


Humidity Tile PageHumidity Sensors……..for Healthcare


COMBINED HUMIDITY & TEMPERATURE SENSOR<strong>The</strong> ChipCap series sensor <strong>of</strong>fers a newstandard for relative humiditymeasurement Simultaneous analog and digital outputs for %RH andTemperature Fully calibrated with no additional calibration required or needed No additional temperature compensation required or needed Absolutely NO further correction <strong>of</strong> %RH, or calculations arenecessary Does not need regulated power supply Virtually “Design Free” True interchangeability311/20/2012


ChipCapIntegrated Humidity & TemperatureProduct / DescriptionRelative Humidity and Temperature with Integratedsignal conditioning ASIC. Compact SOIC (System-on-Chip) package. ChipCap provides either analog ordigital interfaces on a single 5 VDC-powered chip. Dualoutputs provide humidity and temperature.Benefits Accurate Measurements <strong>of</strong> %RH and Temperature Analog or Digital Humidity & Temperature Outputs Long-Term Stability <strong>of</strong>


GE MEASUREMENT & CONTROLS SOUTIONSDIFFERENTIATORSBrand recognitionStrong customer base: Leaders in theirmarket segmentsTraceability: ceramics to completedassemblySolutions: “Thinking outside the Box”Positioned globally with local resources30+ years <strong>of</strong> applications experienceWorld class R & D facilities (4 locations)Financial stability – we’ll be theretomorrow331/20/2012


SUMMARYGE Sensing <strong>of</strong>fers precisioninstruments and systems thatmeasure temperature, pressure,liquid level, humidity, gasconcentration and flow rate. Weprovide customers sensor-basedsolutions that enable them tomonitor, protect, control andvalidate their critical applicationsand processes.341/20/2012