12.07.2015 Views

Understanding the UL Fire Resistance Directories - Ron Blank ...

Understanding the UL Fire Resistance Directories - Ron Blank ...

Understanding the UL Fire Resistance Directories - Ron Blank ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NUMBERING SYSTEM FOR FIRE RATED ASSEMBLIESTYPES OF PROTECTIONMembrane ProtectionNumbering System for <strong>Fire</strong> RatedAssemblies – Types of Protection<strong>Understanding</strong> <strong>UL</strong>Direct AppliedProtectionUnprotectedGroups of Construction 000-099 100-199 200-299 300-399 400-499 500-599 600-699 700-899 900-999Floors-Ceilings A,B*,or C*Concrete and CellularSteel FloorD, E*orF*Concrete and Steel FloorUnitsG, H*, or I*Concrete and Steel JoistsConcealedGrid Sys.ConcealedGrid Sys.ConcealedGrid Sys.(Reserved)(Reserved)(Reserved)Exposed GridSystemExposed GridSystemExposed GridSystem(Reserved)(Reserved)(Reserved)Metal LathMetal LathMetal LathGypsumBoardGypsumBoardGypsumBoardMisc. SFRM + UnprotectedMasticCoatingSFRM +UnprotectedMisc. SFRM + UnprotectedJ or KConcreteConcealedGrid Sys.(Reserved)Exposed GridSystem(Reserved)Metal LathGypsumBoardMisc. SFRM + UnprotectedL or M* Wood Joist orCombination Wood andSteel AssembliesBeams:N or O* for Floor-CeilingRoof-Ceiling:P, Q* or R*Beams:S or T* Roof-CeilingWall & Partition:U, V or W*Columns: X, Y or Z*ConcealedExposed GridGypsum(Reserved)(Reserved) Metal LathGrid Sys. System BoardConcealedGrid Sys.ConcealedGrid Sys.BuildingUnits(Reserved)(Reserved)(Reserved)Bldg. orPartition (Reserved)Panel UnitsBuildingUnitsPrefabricatedExposed GridSystemExposed GridSystemExposed GridSystemInsulatingConcrete(Reserved)Batts &<strong>Blank</strong>ets orMineral andFiber Boards(Reserved)(Reserved)Metal LathMetal LathMetal LathGypsumBoardGypsumBoardGypsumBoardMisc. SFRM + UnprotectedMasticCoating SFRM + UnprotectedMisc.MasticCoatingWood StudMetal StudMetal PanelsGypsum Bd. Gypsum Bd.Gypsum Bd.Misc.Lath and/or Lath and/orLath and/orPlaster PlasterPlasterBatts &<strong>Blank</strong>ets or Metal Lath & Gypsum MasticMineral & Plaster Board CoatingFiber BoardsSFRM +SFRM +SFRM +SFRM +UnprotectedUnprotectedMasonryReserved)The prefix numbers with an asterisk (*) and <strong>the</strong> design numbers indicated as "Reserved" in <strong>the</strong>above table are for future expansion and to cater to new types of systems

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!