3.0 Definitions<br />

This document uses the definitions of International Vocabulary of Metrology (ISO/IEC Guide<br />

99:2007), ISO/IEC 17025:2005(E), ANSI/NCSL Z540.1-1994 (R2002) and ANSI/NCSL<br />

Z540.3-2006, as well as other terms applied to our calibration activities described below.<br />

Instruments<br />

Measuring and Test Equipment (M&TE) – This comprises all of the measuring<br />

instruments, measurement standards, reference materials, and auxiliary apparatus that are<br />

necessary to perform a measurement. This term includes measuring equipment used in the<br />

course of testing and inspection, as well as, that used in calibration.<br />

Measurement Standard – A material measure, measuring instrument, reference material or<br />

system intended to define, realize, conserve or reproduce a unit or one or more known values<br />

of a quantity to serve as a reference. Items used for measuring standards generally fall into<br />

one of the four following categories:<br />

� Primary - A standard, which has the highest metrological qualities in a specified field.<br />

This standard is generally compared directly to national standards.<br />

� Reference - A standard, generally in the highest order in a calibration system, which<br />

establishes the basic accuracy values for that system. A reference standard is used to link<br />

measurement traceability to an external laboratory.<br />

� Transfer - Are designated measuring and test equipment used in a calibration system as<br />

a medium for transferring the basic values of reference standards to lower echelon<br />

transfer standards or measuring and test equipment. In some cases a transfer standard<br />

may be used as a working standard.<br />

� Working Standard - A material, measuring instrument, reference material or system<br />

intended to define, realize, conserve or reproduce a unit or one or more known values of<br />

a quantity.<br />

Measuring Instrument – A device intended to make a measurement, alone or in conjunction<br />

with, supplementary equipment. Furthermore, all products that meet the following criteria are<br />

considered to be a measuring instrument:<br />