12.07.2015 Views

Engine Driven Welders: Weldanpower 125 - semirca, ca

Engine Driven Welders: Weldanpower 125 - semirca, ca

Engine Driven Welders: Weldanpower 125 - semirca, ca

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A CLOSER LOOKARC PERFORMANCE• <strong>125</strong> amps DC welding output gives you access to steel,stainless steel, <strong>ca</strong>st iron or hardfacing projects.• Single, full range welding output control makes it simple todial in the best amperage for your repair, maintenance orfabri<strong>ca</strong>tion project.AC GENERATOR PERFORMANCE• Plenty of 120 or 240 volt AC generator power 5500 wattssurge (4250 watts continuous) for lights, tools, pumps,or emergency power outage needs.FEATURES• <strong>125</strong> amps DC welding output gives you access to steel,stainless steel, <strong>ca</strong>st iron or hardfacing projects.• Single, full range welding output control makes it simple todial in the best amperage for your repair, maintenance orfabri<strong>ca</strong>tion project.• Add a Lincoln SP-135T, SP-135 Plus, SP-175T or SP-175Plus compact MIG welder powered by the <strong>Weldanpower</strong> <strong>125</strong>for high productivity MIG welding on steel, stainless steel oraluminum.• Noise at rated load:103.9 dB sound power (Lwa)79.2 dBA sound level at 23 ft. (7m)• Robin/Subaru 9 HP EX27 OHC (Overhead Cam) engine has:- Steel chain-driven overhead <strong>ca</strong>m for great reliability andlong engine life.- Easy starts with automatic decompression system.- Low noise.- Low fuel consumption.- Cast iron cylinder liner for maximum engine performanceand long life.- 1.6 gallon fuel tank. Includes fuel fill strainer.- Automatic shutdown for low oil level.- 3-Year Robin/Subaru engine warranty.• Compact, lightweight package is up to 40 lbs. (18 kg) lessthan many competitors!• Two people <strong>ca</strong>n easily transport the <strong>Weldanpower</strong> <strong>125</strong> wherewelding and AC generator power are needed.1Key Controls81. Current Control Dial2. 120V AC Receptacles3. 240V AC Receptacle4. Circuit Breakers5. Grounding Stud6. Welding Output Studs7. Electrode Selection Guide8. Hour Meter273465QUALITY AND RELIABILITY• Durable generator design starts with all-copper stator androtor windings with high quality industrial insulation,protected by a low oil-detection shutdown system, helpensure trouble-free reliability and long life.• Maintenance-free electronic ignition with on/offswitch, combined with recoil start featuring automaticdecompression system, make for easy enginestarting.• Rugged tubular roll <strong>ca</strong>ge provides added protection and ahost of handy lift handle points.• Circuit breaker protection for AC power.• Industry-leading three-year Lincoln warranty on partsand labor. (Separate engine warranty permanufacturer).• Manufactured under a quality system certified to ISO9001 requirements.• Approved by the Canadian Standards Association.• Three-year Lincoln warranty on welder.• Three-year engine warranty from Robin/Subaru.[2]<strong>Weldanpower</strong>® <strong>125</strong>www.lincolnelectric.com


A CLOSER LOOKMACHINE SPECIFICATIONSDimensionsProduct Ordering CC Rated Output Generator H x W x L WeightName Information Description Current/Voltage/Duty Cycle AC Power (1) inches (mm) lbs. (kg)<strong>Weldanpower</strong>® <strong>125</strong> K1444-3 <strong>125</strong> Amp DC DC Constant Current 5500 Watts Surge 21 x 20 x 30 180Arc Welder <strong>125</strong>A / 25V/ 30% 4250 Continuous (530 x 508 x 762) (82)with 100A / 25V / 60% 60 Hz, 120V/240V AC (2)5,500 Watts SurgeSingle Phase4,250 Watts ContinuousCurrent Range100% Duty CycleAC Power50-<strong>125</strong> ACircuit Breaker ProtectionMax. OCV@ 3750 RPM80V RMS(1) When welding, available auxiliary power will be reduced.(2) 120V will operate either 60 Hz,or 50/60 Hz power tools, lights, etc.(3) Each branch circuit <strong>ca</strong>n supply up to 17.7 amps at the same time. (Circuits <strong>ca</strong>nnot be wired in parallel tooperate the same device.)120V Duplex Receptacles20 Amps Each35.4 Amps Total (3)240V Receptacle17.7 AmpsENGINE SPECIFICATIONS<strong>Engine</strong> Horsepower & Operating FuelModel Description Displacement Ignition Capacities Speeds ConsumptionRobin/ 1 Cylinder, 4 Cycle, 9 HP @ 3,600 RPM Manual, FUEL: FULL LOAD 0.70 Gals./HrSubaru Overhead Cam 16.2 cu in Recoil Start; 1.6 Gals (6.0 Ltrs) 3,400 RPM 2.66 Ltrs./HrEX 27 (4) Air Cooled, Gasoline <strong>Engine</strong> (265 cc)Aluminum Alloy, Manual OIL: HIGH IDLE 0.31 Gals/HrCast Iron Liner Choke 1.0 Qts (1.0 Ltrs) 3,700 RPM 1.17 Ltrs./Hr(4) Robin/Subaru warranty is three years.ELECTRODE SELECTION GUIDEMaterial Thickness 1/8” and Thinner 1/8” and ThickerElectrodeTypeAmeri<strong>ca</strong>n Welding SocietyClassElectrode Polarity3/32”1/8”5/32”FLEETWELD® 5PE6010DC +50 - 70 A75 - <strong>125</strong> A---FLEETWELD® 35E6011DC +50 - 75 A70 - 110 A80 - <strong>125</strong> AFLEETWELD® 180E6011DC +50 - 80 A55 - 110 A105 - <strong>125</strong> AFLEETWELD® 37E6013DC+ / -70 - 95 A100 - <strong>125</strong> A---EXCALIBUR® 7018E7018DC +70 - 110 A90 - <strong>125</strong> A---JETWELD® LH-73E7018DC +65 - 85 A90 - <strong>125</strong> A---BLUE MAX® 308/308L AC-DC E308-17 & 308L-17DC +40 - 80 A75 - 110 A95 - <strong>125</strong> ASOFTWELD® 99NiENi-CIDC +50 - 80 A80 - 110 A100 - <strong>125</strong> AWEARSHIELD® ABR ---DC +---50 - <strong>125</strong> A---The values listed above are suggested settings. Actual setting may vary depending on individual preference and/or specific appli<strong>ca</strong>tion. Follow tables found in accompanyingLincoln literature for those electrodes not listed. Ask for Lincoln Publi<strong>ca</strong>tion C2.10 for a complete listing of all Lincoln stick electrodes.[3]<strong>Weldanpower</strong>® <strong>125</strong>www.lincolnelectric.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!