12.07.2015 Views

Electrical contact devices For pressure and temperature gauges

Electrical contact devices For pressure and temperature gauges

Electrical contact devices For pressure and temperature gauges

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Electrical</strong> <strong>contact</strong> <strong>devices</strong><strong>For</strong> <strong>pressure</strong> <strong>and</strong> <strong>temperature</strong> <strong>gauges</strong>Integrated in housing<strong>For</strong> dial size 100 <strong>and</strong> 160 mmFeatures• Intrinsically safe with inductive <strong>contact</strong>s• Inductive <strong>and</strong> magnetic spring <strong>contact</strong>s• Up to 3 <strong>contact</strong>s• Switch rating up to 1 A 250 VAC• <strong>For</strong> dry or liquid filled <strong>gauges</strong>ApplicationsMeasuring type Pressure Diff. <strong>pressure</strong> TemperatureMeasuring principle Bourdon tube Diaphragm Diaphragm Gas actuatedInstruments T5500 P5500 F5503/F5509 S5500Minimum range in bar mbar mbar °C<strong>For</strong> dial size in mm 100 160 100 160 100/160 100/160<strong>and</strong> 1 inductive <strong>contact</strong>2 inductive <strong>contact</strong>s3 inductive <strong>contact</strong>sor1 magnetic spring <strong>contact</strong>2 magnetic spring <strong>contact</strong>s3 magnetic spring <strong>contact</strong>s1,01,61,61,01,64,01,01,61,61,01,62,54010010040100250401002504010025060100100100100100All ranges are possibleTechnical specification Magnetic spring <strong>contact</strong> Inductive <strong>contact</strong>Max. numbers of <strong>contact</strong>s 3 2Switch functions1 closes at increasing process2 opens at increasing process1 initiator damped at increasing process(relay energizes)2 initiator free at increasing process(relay de-energized)3 change over (SPDT) (max. 2 <strong>contact</strong>s)Contact assignmentAdjustable rangeContact 1 left h<strong>and</strong> setpoint, Contact 2 right h<strong>and</strong> setpoint with 2 <strong>contact</strong>s <strong>and</strong> middle setpoint with3 <strong>contact</strong>s, Contact 3 right setpoint with 3 <strong>contact</strong>sOver full scaleDeadb<strong>and</strong> (hysteresis)±2 to 4 % F.S.<strong>Electrical</strong> specificationOnly to be used in conjunction with an suitableDesignMaking <strong>and</strong> braking currentNominal currentLoadCurrent consumptionSelf inductanceSelf capacitanceInsulation voltageExplosion proof (ATEX)<strong>Electrical</strong> connectionLocationMaterialNumber of terminalsMax. wire sizeCable connectionProtection according EN 60 529/IEC 529Material <strong>contact</strong>sMax. 1 A 250 VAC (see switching capacity graph)Max. 0,6 AMax. 30 W/50 VA (see switching capacity graph)Left sided, others on requestPolyamide 66 + PE2,5 mm 2M20x1,5IP65Silver palladium (AgPd 80/20 ), min. 24 VDC<strong>and</strong>/or approved amplifier relayDIN 19 234 (NAMUR)8 VDCInitiator damped ≤ 1 mA, free ≥ 3 mA29 µH20 nF500 VII 2 G c IIC T6 EEx ia IIC T6only for zone 1 <strong>and</strong> zone 2 (only for T5500)Not applicableOptional Sinidur gold plated, max. 12 VDCAccuracy Rated accuracy of gauge doesn't exceed 150 % of <strong>gauges</strong> without <strong>contact</strong>s in according to DIN 16 085General specificationPermissibleAmbient <strong>temperature</strong>Storage <strong>temperature</strong>Filling liquids-20 ... 70 °C-40 ... 70 °CNapvis (for T5500, F5503 <strong>and</strong> F5509), silicone (for S5500 <strong>and</strong> P5500), others on request (only if gauge isliquid filled design)Integral in gauge housingMountingAdditional weight dry/filled in kg 100 mm: 0,3/1,0; 160 mm: 0,4/1,5Accessories, optionsAmplifier relay for inductive <strong>contact</strong>s EEx <strong>and</strong> st<strong>and</strong>ardAll specifications are subject to change without notice.G1.K55/E Rev. G 21/04/2008


Order informationMagnetic spring <strong>contact</strong>sContactcodeSingle <strong>contact</strong>M1000M2000Switch functionat increasingprocessContact closesContact opensTypical diagram(at zero position)Inductive <strong>contact</strong>sContactcodeSingle <strong>contact</strong>I1000(st<strong>and</strong>ard)I1000SN(safety design)I2000(st<strong>and</strong>ard)I2000SN(safety design)Switch function at increasingprocessCurrent flowsNo current flowsEquivalentcircuit diagram(at zero position)Position of controlvane(at zero position)Dual <strong>contact</strong>M1100M2200M1200M2100Triple <strong>contact</strong>sM1110M2220M1220M2110Contact 1 closesContact 2 closesContact 1 opensContact 2 opensContact 1 closesContact 2 opensContact 1 opensContact 2 closesContact 1 closesContact 2 closesContact 3 closesContact 1 opensContact 2 opensContact 3 opensContact 1 closesContact 2 opensContact 3 opensContact 1 opensContact 2 closesContact 3 closesDual <strong>contact</strong>I1100(st<strong>and</strong>ard)I1100SN(safety design)I2200(st<strong>and</strong>ard)I2200SN(safety design)I1200(st<strong>and</strong>ard)I1200SN(safety design)I2100(st<strong>and</strong>ard)I2100SN(safety design)Switching voltage in V24022020018016014012010080Contact 1 current flowsContact 2 current flowsContact 1 no current flowsContact 2 no current flowsContact 1 current flowsContact 2 no current flowsContact 1 no current flowsContact 2 current flowsSwitching capacity graphs for <strong>contact</strong> <strong>devices</strong>LoadMagnetic spring <strong>contact</strong>Max. load: 30 W-50 VA-1 AMax. switching voltage: 250 VM1210M2120M1120M2210Contact 1 closesContact 2 opensContact 3 closesContact 1 opensContact 2 closesContact 3 opensContact 1 closesContact 2 closesContact 3 opensContact 1 opensContact 2 opensContact 3 closes604020Microswitch SPDT (max. rating 3A 250 VAC/400 mA 30 VDC), for case ∅100/160Contactcode00 100 200 300 400 500 600 700 800 900 1000Q3(1 microswitch)Q33(2 microswitch)Pressure Differential <strong>pressure</strong> Temperature(diaphragm gauge)P5500 F5502 S5500min. 0/1,6 bar(no case filling)Switching current in mAall ranges(case filling onlyNAPVIS)50 VA (AC)30 W (DC)all ranges((no case filling)Consult factory for other <strong>contact</strong> types <strong>and</strong> number of <strong>contact</strong>s, such as two independent <strong>contact</strong>s, pneumatic, slide wire <strong>and</strong> others.Order exampleContact typeM1200Add <strong>contact</strong> code to the selected gauge coding.Ashcroft Instruments GmbH Website: www.ashcroft.eu e-Mail: sales@ashcroft.comGermanyMax-Planck-Str. 1, D-52499 BaesweilerP.O. Box 11 20, D-52490 BaesweilerTel.: +49 (0) 2401 808-0, Fax: +49 (0) 2401 808-125France„206“ ZA du M<strong>and</strong>inet, 1/3 Rue des CampanulesF-77185 LognesTel.: +33 (0) 1 60 37 25 30, Fax: +33 (0) 1 60 37 25 39United KingdomUnit 5 William James HouseCowley Road, Cambridge CB4 0WXTel.: +44 (0) 12 23 39 55 00, Fax: +44 (0) 12 23 39 55 01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!