Parameter settings for Danfoss VLT ® 6000 HVAC0–<strong>10</strong>V <strong>signal</strong> from controllerThe parameters used to control the frequency converters may be easily programmedby the user. The [QUICK MENU] button provides a list with a some of the mostcommon parameters. The [EXTEND. MENU] button allows the user to program allparameters.<strong>Johnson</strong> <strong>Pump</strong> Horticulture provides you with this <strong>Quick</strong> Start guide for optimizingyour pump performance.This guide assumes you are using the Display in Display mode II.Parameter settingsGroup 0 - Operation & DisplayParam. no.001DescriptionLanguageWindow textLANGUAGESettingENGLISH005 Max. value of user-de ned readout CUSTOM READOUT 600.00Serial port value007 Large display readout LARGE READOUT FREQUENCY [Hz] 3008 Small display readout 1.1 SMALL READOUT 1 SET POINT 1 [UNITS] 1<strong>10</strong>09 Small display readout 1.2 SMALL READOUT 2 FEEDBACK 1 [UNITS] 130<strong>10</strong> Small display readout 1.3 SMALL READOUT 3 ANALOG INPUT 60 [mA] 23Group 1 - Load & MotorParam. no.DescriptionWindow textSetting0Serial port value<strong>10</strong>0 Con gurationCONFIG. MODE OPEN LOOP0Group 2 - References & LimitsParam. no.DescriptionWindow textSettingSerial port value201 Output frequency low limit, f MINMIN. FREQUENCY 0.000 Hz0202 Output frequency high limit, f MAXMAX. FREQUENCY 50.000 Hz50000204 Minimum reference, Ref MINMIN. REFERENCE 0.000 HZ0205 Maximum reference, Ref MAXMAX. REFERENCE 50.000 Hz50000206207Ramp-up time 1Ramp-down timeGroup 3 - Inputs & OutputsParam. no.3083093<strong>10</strong>DescriptionTerminal 53, analogue input voltageTerminal 53, min. scalingTerminal 53, max. scalingRAMP UP TIME 1RAMP DOWN TIME 1Window textAI [V] 53 FUNCT.AI 53 SCALE LOWAI 53 SCALE HIGH15.00 sec.15.00 sec.SettingREFERENCE0.0 V<strong>10</strong>.0 V15001500Serial port value<strong>10</strong><strong>10</strong>0314 Terminal 60, analogue input current AI [mA] 60 FUNCT. NO OPERATION 0All other parameter settings --> factory default setttings<strong>Johnson</strong> <strong>Pump</strong> HorticultureDe Hondert Margen 23 • 2678 AC De Lier • NETHERLANDSTelephone: +31 (0)174 51 84 <strong>10</strong> • Fax: +31 (0)174 51 84 44 • Email: johnson-pump.horticulture@spx.comwww.johnson-pump.com/horticulture1


Parameter settings for Danfoss VLT ® 6000 HVAC0–<strong>10</strong>V <strong>signal</strong> from controllerTroubleshootingNot working?Parameter 620 [OPERATION MODE]/[INITIALIZE] can be used to restall parameters to the default factory settings.Procedure for intitialisation:1. Select initialisation (parameter 620)2. Press [OK]3. Disconnect mains power supply and wait for the light in thedisplay to go out4. Reconnect to mains5. Initialisation of alll parameters will be carried out6. Reprogram the above parametersWiring diagramThe connection between terminal 12 and 18 can be replaced by a contactfrom the controller.Press [DISPLAY MODE].Three values are shown at the top of the display; parameter settings008, 009 and 0<strong>10</strong>.The value on the far right is the voltage connected to terminal 53.2<strong>Johnson</strong> <strong>Pump</strong> HorticultureDe Hondert Margen 23 • 2678 AC De Lier • NETHERLANDSTelephone: +31 (0)174 51 84 <strong>10</strong> • Fax: +31 (0)174 51 84 44 • Email: johnson-pump.horticulture@spx.comwww.johnson-pump.com/horticulture

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!