12.07.2015 Views

Energy Audit Report of the General Hospital Building in ... - Tkibuli Tea

Energy Audit Report of the General Hospital Building in ... - Tkibuli Tea

Energy Audit Report of the General Hospital Building in ... - Tkibuli Tea

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

8 <strong>Energy</strong> Efficiency Measures8.1 List <strong>of</strong> MeasuresThe follow<strong>in</strong>g EE and renovation measures are evaluated and described <strong>in</strong> detail <strong>in</strong> thischapter. A list <strong>of</strong> pr<strong>of</strong>itable EE measures is provided <strong>in</strong> <strong>the</strong> table below:1. Insulation <strong>of</strong> walls4. Insulation <strong>of</strong> ceil<strong>in</strong>g5. Installation <strong>of</strong> fluorescent bulbs<strong>Energy</strong> Efficiency and Renovation Measures8.2 MeasuresA description <strong>of</strong> all measures that have been evaluated is given below.MeasureCurrent Situation1. – Insulation <strong>of</strong> WallsThe walls <strong>of</strong> <strong>the</strong> hospital build<strong>in</strong>g are constructed from concrete blocks. The thickness <strong>of</strong> <strong>the</strong> walls is0.5 m, but <strong>the</strong>re are still considerable <strong>the</strong>rmal losses through <strong>the</strong> exterior walls.Description <strong>of</strong> MeasureIn order to reduce heat loses it is feasible to <strong>in</strong>sulate <strong>the</strong> <strong>in</strong>ner surface <strong>of</strong> <strong>the</strong> walls with 0.05m glasswool and 0.01m thick gypsum boards fac<strong>in</strong>g.Calculation <strong>of</strong> Sav<strong>in</strong>gs (by ENSI ® Key Number S<strong>of</strong>tware or o<strong>the</strong>r tool)The above measure requires <strong>the</strong> <strong>in</strong>sulation <strong>of</strong> 263 m 2 walls.-Gypsum board, 17 GEL/m 2 x 263 = 4471 GEL-Insulation, 3 GEL/ m 2 x 263 = 789 GELThe total <strong>in</strong>vestment constitutes 5260 GEL.The amount <strong>of</strong> saved energy calculated by <strong>the</strong> s<strong>of</strong>tware program was def<strong>in</strong>ed as 38129 kWh/y. Inmonetary terms this will constitute: 38129 x 0.15 = 5719 GEL (0.15 GEL is <strong>the</strong> price <strong>of</strong> heat per kWh<strong>of</strong> electricity).Investment:Design/Plann<strong>in</strong>g 100 GELProject Management 100 GELInsulation/Installation <strong>of</strong> <strong>the</strong> Walls 5260 GELControl and Test<strong>in</strong>g 49500 290 GELAs-built Documentation 0 GELO<strong>the</strong>r Expenses 100 GEL16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!