Measure. 3. – Install<strong>in</strong>g <strong>the</strong> New Light<strong>in</strong>g SystemCurrent SituationCurrently <strong>the</strong> Bakuriani <strong>General</strong> <strong>Hospital</strong> <strong>Build<strong>in</strong>g</strong> is ma<strong>in</strong>ly <strong>in</strong>stalled with <strong>in</strong>casendent bulbs forlight<strong>in</strong>g.Description <strong>of</strong> MeasureThe energy audit team has decided to renovate <strong>the</strong> light<strong>in</strong>g system <strong>in</strong> <strong>the</strong> <strong>Hospital</strong> <strong>Build<strong>in</strong>g</strong> <strong>in</strong> order tocreate comfortable conditions. It was concluded that energy efficient bulbs should be <strong>in</strong>stalled.Calculation <strong>of</strong> Sav<strong>in</strong>gs (by ENSI ® Key Number S<strong>of</strong>tware or o<strong>the</strong>r tool)The basel<strong>in</strong>e energy amount <strong>of</strong> <strong>the</strong> light<strong>in</strong>g system constitutes 14476 kWh/y. It was identified by <strong>the</strong>s<strong>of</strong>tware program that by <strong>in</strong>stall<strong>in</strong>g a modern light<strong>in</strong>g system with compact fluorescent bulbs, <strong>the</strong>amount <strong>of</strong> saved energy will constitute 2163 kWh/y. Calculat<strong>in</strong>g this amount <strong>of</strong> energy by <strong>the</strong>electricity tariff, we will get a sav<strong>in</strong>gs <strong>in</strong> monetary terms <strong>of</strong>: 2163 x 0,19=411 GEL.The <strong>in</strong>vestment <strong>in</strong>to replac<strong>in</strong>g <strong>the</strong> exist<strong>in</strong>g light<strong>in</strong>g system with an efficient one <strong>in</strong>clud<strong>in</strong>g <strong>the</strong><strong>in</strong>stallation constitutes 500 GEL:-50 fluorescent bulbs (10 GEL/Piece) – 500 GELInvestment:Design/Plann<strong>in</strong>g 10 GELProject Management 50 GELInstall<strong>in</strong>g <strong>the</strong> New Light<strong>in</strong>g System 50 GELRequired Components 500 GELControl and Test<strong>in</strong>g 100 GELAs-built Documentation 0 GELO<strong>the</strong>r ExpensesGELTotal Investment 710 GELO&M Expenses Per Year (+/-) 0 GEL/yearNet Sav<strong>in</strong>gs 411 GEL/yearEconomc Lifetime 5 years18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!