<strong>RH</strong>-<strong>TRAMPAC</strong> Document Rev. 0, June 20062.7.1 Requirements2.7 Sealed ContainersSealed containers that are greater than 4 liters (nominal) are prohibited except for metalcontainers packaging solid inorganic waste. Solid inorganic wastes packaged in metal containersdo not generate any flammable gas (see Appendix 2.2 <strong>of</strong> the <strong>RH</strong>-TRU Payload Appendices 1 ).2.7.2 Methods <strong>of</strong> Compliance and VerificationCompliance shall be by one, or a combination <strong>of</strong>, the following methods:• Review <strong>of</strong> records and database information, which may include knowledge <strong>of</strong> process• Radiography• Visual examination• Sampling program.1 U.S. <strong>Department</strong> <strong>of</strong> Energy (DOE), <strong>RH</strong>-TRU Payload Appendices, current revision, U.S. <strong>Department</strong> <strong>of</strong> Energy,Carlsbad Field Office, Carlsbad, New Mexico.2.7-1