START-UP OF POWER VT ® WATER HEATERS OR BOILERS**FOR DETAILED INFORMATION SEE INSTALLATION & MAINTENANCE MANUAL **WARNING: These <strong>start</strong><strong>up</strong> instructions are prepared f<strong>or</strong> a qualified service installer, serviceagency <strong>or</strong> gas s<strong>up</strong>plier and require and rely on the experience and training <strong>of</strong> thesequalified gas appliance technicians to be safely <strong>com</strong>pleted. Attempting to follow theseinstructions without such training and experience can result in property damage, exposureto hazardous materials, personal injury <strong>or</strong> death.1. Check the <strong>water</strong> heater tank to make sure it is full <strong>of</strong> <strong>water</strong>. (Remove air through T&P valve)2. Remove enclosure panel cover on the <strong>water</strong> heater to expose control circuit. A wiring diagram, included in thispacket, will show the controls used in our circuitry.3. Visually check that all <strong>com</strong>ponents are intact and no damage has occurred during transit.4. Check all connections within the control cabinet. A loose connection could cause intermittent shutdowns.5. Check flue gases with an electronic flue analyzer to make final settings <strong>of</strong> gas pressure regulat<strong>or</strong>.6. The readings need to be taken from a hole in the vent several inches downstream <strong>of</strong> the fan outlet connection.7. Insert 0-6" W.C. manometer into the test opening in the vent. Pressure in stack should not exceed 2" W.C.8. When <strong>water</strong> in tank is above 120°F, insert analyzer <strong>or</strong> O 2 testing in test opening; take O 2 reading in percentage.9. Increase manifold gas pressure at the main gas pressure regulat<strong>or</strong> taking O 2 reading at each adjustment <strong>of</strong> gasregulat<strong>or</strong> until optimum O 2 % (5-7%) is reached. If O 2 % decreases, reduce the gas pressure to last readingwhere the greatest reading is achieved.10. CO should not exceed 200 ppm. A reading greater than 200 ppm indicates lack <strong>of</strong> air. Reduce manifold gaspressure slightly and take readings until CO is within proper range. Optimum reading is no CO.11. If manifold pressure was changed during <strong>start</strong><strong>up</strong>, take a final CO and O 2 reading.12. Rec<strong>or</strong>d CO 2 and NO x if applicable. (See I&M if NO x measurement is required).13. Insert vent temperature gauge in test opening and read gross vent temperature; maximum gross stack is to be250°F. If an excessively high gross vent temperature is rec<strong>or</strong>ded, consult the fact<strong>or</strong>y.14. Check each operating and limit control to be sure they function properly by lowering and raising the temperaturesetting on each <strong>of</strong> the controls, causing burner to cycle on and <strong>of</strong>f.15. NOTE: During the initial firing <strong>of</strong> the burner, smoke that is not related to the burner will be emitted from theheater. This is n<strong>or</strong>mal during "burn in" and could possibly continue f<strong>or</strong> several hours.16. Complete the attached <strong>start</strong><strong>up</strong> rep<strong>or</strong>t.Imp<strong>or</strong>tant – Contact PVI Customer Service, 800-433-5654, if any re<strong>com</strong>mended setpoint <strong>or</strong> analysisreading falls outside <strong>of</strong> the re<strong>com</strong>mended ranges bef<strong>or</strong>e <strong>com</strong>pleting <strong>start</strong><strong>up</strong>.PV 413A 8/05


START-UP REPORTPOWER VT ® WATER HEATERS OR BOILERSWarning: Start<strong>up</strong> must be perf<strong>or</strong>med by a qualified service installer, service agency <strong>or</strong> the gas s<strong>up</strong>plier.Model Number:Serial Number:Job Name:Address:GENERAL INFORMATIONRe<strong>start</strong>? Yes No Installation is: New Replacement/Renovation Indo<strong>or</strong> Outdo<strong>or</strong>Primary operating voltage s<strong>up</strong>ply: VAC Voltage from neutral to earth ground: (should be zero)Thermostat Setting: °F Thermostat Setting: °F Hi-Limit Setting °FIs the T & P Relief Valve plumbed to a suitable drain? Yes NoBOILER INSTALLATIONS (Closed Loop Heating System)Boiler <strong>water</strong> s<strong>up</strong>ply and return piping size Is there a Primary (boiler bypass) loop? Yes NoPrimary (boiler bypass) loop contains: Modulating 3-way valve Manual valve No valveWhat is the h<strong>or</strong>se<strong>power</strong> <strong>of</strong> the primary (boiler loop) circulat<strong>or</strong> pump? VFD? Yes NoWhat is the location <strong>of</strong> the primary circulat<strong>or</strong> pump? Downstream from boiler Upstream from boilerIs there a balancing valve (circuit setter) in the primary loop? Yes NoS<strong>up</strong>ply <strong>water</strong> temperature: °F Return <strong>water</strong> temperature: °FWhat is the h<strong>or</strong>se<strong>power</strong> <strong>of</strong> the secondary (main heating loop) circulat<strong>or</strong> pump? VFD? Yes NoWhat is the location <strong>of</strong> the secondary circulat<strong>or</strong> pump? Downstream from boiler Upstream from boilerIs there a balancing valve (circuit setter) in the secondary loop? Yes NoWATER HEATER INSTALLATIONSType <strong>of</strong> piping connected to heater: Copper Brass GalvanizedIs there a check valve in the s<strong>up</strong>ply <strong>water</strong> piping? Yes NoIs there a <strong>water</strong> s<strong>of</strong>tener on the cold <strong>water</strong> s<strong>up</strong>ply? Yes No Operational? Yes NoIs there a mixing valve on the hot <strong>water</strong> s<strong>up</strong>ply? If yes; temperature setting: °F NoIs there expansion relief in the cold <strong>water</strong> s<strong>up</strong>ply? If yes, what type: tank valve NoIs there a recirculation loop? Yes Circulating pump h<strong>or</strong>se<strong>power</strong>: NoIs there a flo<strong>or</strong> drain in the room? Yes NoPV 413 8/05817-335-9531 ● 800-433-5654 ● FAX 800-880-2019 ● www.pvi.<strong>com</strong>Page 1 <strong>of</strong> 2


Model Number:Serial Number:VENTING and COMBUSTION AIRVent Material:(CPVC – Water Heaters Only; AL29-4C Stainless Steel – Boilers <strong>or</strong> Water Heaters)Vent Diameter: inches; Vent Length: feet Vent Type: Through-the-ro<strong>of</strong> Through SidewallDoes vent have condensate drain? Yes No Does vent have elbows? Yes; Qty NoDoes vent contain any <strong>of</strong> these devices? Power Vent Draft Inducer Draft Regulat<strong>or</strong> Flue DamperCombustion air louvers <strong>or</strong> openings? Yes; Qty: Size: No Interlocked? Yes NoHave direct-ducted <strong>com</strong>bustion air? Yes; duct diameter inches, length feet. NoDuct Material: Does duct have elbows? Yes; Qty NoGAS SUPPLYType <strong>of</strong> Gas: Natural LP Inlet Static Gas Pressure: “W.C. (14”W.C. maximum)Gas S<strong>up</strong>ply Pipe Size: Inlet Flow Gas Pressure: “W.C. (see data label)Combination Gas Pressure Switch Setting: High “W.C. Low “W.C.COMBUSTION ANALYSISHeatersBoilers1 st Stage 2 nd StagePilot Gas PressureManifold Gas PressureCarbon Dioxide CO 2 (8-9%)Oxygen O 2 (5-7%)Carbon Monoxide CO (less than 200 ppm)Nitrogen Oxide NO X (if available)Vent Pressure (+.25” to + 2.0” W.C.)Gross Vent Temperature (maximum 230°F)less Room Temperature °F= Net Vent Temperature °FImp<strong>or</strong>tant: You must submit the <strong>or</strong>iginal copy <strong>of</strong> the <strong>com</strong>pleted f<strong>or</strong>m to your PVI representative bef<strong>or</strong>e thewarranty will be<strong>com</strong>e effective on this product. Contact Customer Service f<strong>or</strong> assistance at 1-800-433-5654.Service Company Name:Phone:Service Co. Address:Start-<strong>up</strong> Perf<strong>or</strong>med By:Date:Customer: Phone No.: Date:PV 413 8/05817-335-9531 ● 800-433-5654 ● FAX 800-880-2019 ● www.pvi.<strong>com</strong>Page 2 <strong>of</strong> 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!