Temperature transmitterwith digital adjustment<strong>GTMU</strong> - IF1<strong>GTMU</strong> - IF2<strong>GTMU</strong> - IF3HLFLFLD<strong>GTMU</strong> - IF1(standard: FL = 100 mm, D = 6 mm)D<strong>GTMU</strong> - IF2(standard: FL = 100 mm, D = 6 mm, G1/2")FLD<strong>GTMU</strong> - IF3(standard: HL = 100 mm, FL = 50 mm, D = 6 mm, G1/2")Specification:Meas. range: The probe length FL has to be chosen long enough, thatthe allowable temperature range of the electronics situatedin the tube sleeve is not excee<strong>de</strong>d.<strong>GTMU</strong> – IF1 (standard): - 30,0 ... +100,0 °C<strong>GTMU</strong> – IF2 (standard): - 30,0 ... +100,0 °C<strong>GTMU</strong> – IF3 (standard): - 70,0 ... +400,0 °Cother measuring ranges (max. -200 ... +500 °C) upon requestMeas probe: internal Pt1000-sensorAccuracy: (at nominal temperature = 25 °C)Electronic: ±0,2 % of meas. value ±0,2 °CMeßfühler: standard: DIN class Boptionally higher sensor accuracy availableOutput signal: 4 …20 mA (2-wire)Auxiliary energy: Uv = 10 … 30 V DCPermissible bur<strong>de</strong>n: R A (U V - 10 V) / 0,022 A [R A in Ohm, U v in V]Scaling: the transducer can be scaled freely within the measuringranges via <strong>GTMU</strong>-IF programming tool.Operating temperature of electronic (in tube sleeve) : -25 to 60 °CHousing: stainless steel housingDimensions: <strong>de</strong>pending on sensor constructiontube sleeve: Ø15 x 35 mm (without screwing)tube length FL: 100 or 50 mm or on customer requirementtube diameter D: Ø 6 mm or on customer requirement(available Ø: 4, 5, 6 and 8 mm)collar tube length HL: 100 mm or on customer requirementthread:G1/2“ or on customer requirement(available threads M8x1, M10x1, M14x1.5, G1/8“, G1/4“, G3/8“, G1/2“, G3/4“)Electric connection: approx. 1 m long 4-pin cable(2 x current loop, 2 x interface)Options (upcharges):- FL=...: longer tube, each started further 100mm- HL=...: longer collar tube, each started further 100mm- D=...: other tube diameter- G=...: other thread upon request- MB=...: other measuring ranges, set by factoryAccessories:<strong>GTMU</strong>-IF - Programming toolUSB-interface adaptor for <strong>GTMU</strong>-IF, incl. configuration softwareAnalog Pt100-transmitterwith digital adjustmentT03 BU /WE *1(transmitter 0-10V, set by our works)*1= please specify <strong>de</strong>sign-type <strong>de</strong>sired on your or<strong>de</strong>r.e.g. T03BU, Pt100 3-wire, 0...10 V = 0 - 250 °CGeneral: These transmitter are <strong>de</strong>signed for industrial applicationsand are used to measure the temperature through Pt100resistance thermometers in 2-/3-wire circuits connections.The 0...10 V output signal is linear with temperature.The advantages of a continuous analog signal path and those ofdigital adjustment have been combined in the realization of thistransmitter series.Specification:Measurement input: Pt100 (DIN EN60751)Range limits: -200 ... +850 °CMeas. span: 40 to 1050 KZero shift: at span < 75K: -40, -20, 0, 20 or 40 °Cat span 75K: ± 50 °Cat span > 75K: ± (span * 0.2 + 35 °C)Sensor connection: 2- or 3-wire connectionMeas. current: < 0,5 mAMax. perm. line resistance (3-wire): 11 Ohm per conductorSampling time: continuous because of analog signal pathOutput signal: 0…10 Volt, 3-wire technologySetting time on a temperature change: 10 msTransfer characteristic: linear with temperatureTransfer accuracy: ±0.2 % FSCalibration accuracy: ±0.2 °C or ±0.2 % FSSupply voltage: U B 15 … 30 V DCSupply voltage error: ±0.01 % FS / VPermissible load R L : R L 10 kOhmLoad error: ±0.1% FSOperating temp.: -40 … +85 °CRelative humidity: 0... 95 %RH (non con<strong>de</strong>nsing)Storage temperature: -40 … +100 °CElectromagnetic compatibility (EMC):conforming to acc. to DIN EN 61326Electric connection: via terminals,cross section of connection terminals max. 1,75 mm²Housing:PC-housing, suitable for installation in connectionhead acc. to DIN 43729 form B.Operating position: unrestrictedDimensions: Ø 44 mm x 21 mmIP-rating:housing: IP54, connection terminals: IP00Weight:approx. 45 gAccessories:Rail adapter(rail adapter for snap-on to top-hat rail)Programming tool for T03BUThe programming tool consists of: configurations software, connectioncable RS 232-C (approx. 1m long, 9-pin Dsub-plug)81Alarm / Protection Temperature probeTransmitterLogger / EASYBus Display / Controller Handheld instrument
Alarm / Protection Temperature probeTransmitterLogger / EASYBus Display / Controller Handheld instrumentTemperature-measuring transducer 4-20mA, Pt100, 2- / 3- or 4-wirefor head and rail case mountingPanel-mounted-resistance thermometer with measuring transducer RT420RT420 / WE *1head transmitter, set by our worksRail adapter upcharge: .for snap-on the RT420 to top-hat railRT420 - SG / WE *1set by our works and mounted in snap-on rail housing*1= Or<strong>de</strong>ring data required:1. required probe connection (2- / 3- or 4-wire)2. measuring range from / to (max. range: -200 ... +850 °C)Or<strong>de</strong>r exampley: RT420 / WE, 4-wire, 0...50 °CRT420-SG / WE, 3-wire, -50...+150 °CGTF103/RT420RT420 withrail adapterGTF103 / RT420 (p.r.t. page 108)Panel-mounted resistance thermometerPt100 cpl. with measuring transducer RT420 - transducer and Pt100 canbe taken out in form of an insert. (Price valid for standard length 100 mmand temperature range as to customers specification between -50 ... +400 °C)Special <strong>de</strong>signs upon request - please contact us!RT420-insertwith Pt100-sensor ofa GTF103/RT420RT420 - advantages:• low-price and robust (complete sealed - no pots, therefore vibration resistantand long time stable)• freely programmable - extreme wi<strong>de</strong> measuring range of -200 to 850 °C(measuring span already from ≥ 25 °C)• selectable probe connection as 2- / 3- or 4-wire• high accuracy ( 0.1% )• large ambient temperature range (-40 ... +85°C)• error message in case of sensor damage or sensor short-circuit• functional warranty 5 years6Alu-head orplastic(upon request))FLSpecification:Measuring range: -200 ... +850 °C, universally programmableMeasuring span: 25 to 1050 KZero shift: -200 ... +825 °CResolution: 14 bitSensor connection: 2-, 3- or 4-wire connectionMeas. current: < 0,3 mAPerm. resistance of connection cable: max. 20 Ohm / wireCompensation for cable error: ±0,02 K / Ohm (at 3-wire)Sensor monitoring: monitoring for sensor damage and short-circuitMeas. cycle: < 700 msLinearisation: linear to temperature acc. to IEC/DIN/EN 60 751-2Accuracy: ±0.25 °C or ±0.1% of meas. spanTemperature effect: < ±0.01% / 1KAnalog output: 4…20 mA, 2-wire technologyAccuracy output: