- Page 1 and 2: International Competitive BiddingRE
- Page 3 and 4: CONTENTSCMPDIRequest for Qualificat
- Page 5 and 6: CMPDILIST OF EXHIBITS/ ATTACHMENTS/
- Page 7 and 8: CMPDI9 BCCL’s Obligations A. For
- Page 9 and 10: CMPDI16 Components of Bid Price Bid
- Page 11 and 12: 310208112 (Madh NLW Jan ‘09) BN -
- Page 13 and 14: 310208112 (Madh NLW Jan ‘09) BN -
- Page 15 and 16: CMPDIBCCL reserves the right to rej
- Page 17 and 18: LoALRMCMESQmmMoU/ MOUMSQMtpaNITNLWP
- Page 19 and 20: CMPDI2. DEFINITIONSNote : The singu
- Page 21 and 22: CMPDI‘Beneficiation plant/ Washin
- Page 23 and 24: CMPDIdeclaration by the Owner howev
- Page 25 and 26: CMPDIinstrumentalities necessary fo
- Page 27: CMPDI‘Request for Qualification o
- Page 31 and 32: CMPDI3. INTRODUCTION & BACKGROUNDBC
- Page 33 and 34: CMPDI3.2.1.2 OPERATION & MAINTENANC
- Page 35 and 36: CMPDI3.2.1.6 ENVIRONMENTAL AND OTHE
- Page 37 and 38: 1. Washery Capacity : 5.0 Mtpa of r
- Page 39 and 40: CMPDIDESCRIPTION OF THE SELECTIONPR
- Page 41 and 42: Envelope 2 :Envelope 3 :CMPDIBid fo
- Page 43 and 44: CMPDIIn case, there is more than on
- Page 45 and 46: 4.2 PRE-BID CONFERENCECMPDIThe Bidd
- Page 47 and 48: CMPDIQUALIFYING REQUIREMENTS3102081
- Page 49 and 50: CMPDIformat given in the RFP bid do
- Page 51 and 52: CMPDINote: 1. Bidders are required
- Page 53 and 54: CMPDI6. INSTRUCTIONS TO BIDDERS6.1
- Page 55 and 56: 6.2 SUBMISSION OF OFFERS AGAINST BI
- Page 57 and 58: CMPDIfigures and words, values indi
- Page 59 and 60: CMPDIfor meeting the Qualifying Req
- Page 61 and 62: CMPDI6.5.2 FINANCIAL SECURITYFinanc
- Page 63 and 64: 6.8 TIME SCHEDULE FOR BID EVALUATIO
- Page 65 and 66: CMPDIINTEGRITY PACT310208112(Madh N
- Page 67 and 68: ii)iii)CMPDIor third person, any ma
- Page 69 and 70: ii)iii)iv)CMPDIThe Bidder accepts a
- Page 71 and 72: CMPDI7.9 EXTERNAL INDEPENDENT MONIT
- Page 73 and 74: iv)CMPDIShould one or several provi
- Page 75 and 76: CMPDIE0XHIBIT 1: FORMAT OF THE COVE
- Page 77 and 78: CMPDI5. We have enclosed the Bid Se
- Page 79 and 80:
CMPDIEXHIBIT 3: FORMAT OF MEMORANDU
- Page 81 and 82:
CMPDIDocument shall remain valid fo
- Page 83 and 84:
CMPDIEXHIBIT 4: FORMAT FOR SUBMISSI
- Page 85 and 86:
CMPDI(2) Detail of Operating Experi
- Page 87 and 88:
CMPDIand agreeing in principle to m
- Page 89 and 90:
CMPDI5) We, the said Bank lastly un
- Page 91 and 92:
CMPDI3. Our counters …………
- Page 93 and 94:
CMPDIEXHIBIT 8: FORMAT OF NOTIFICAT
- Page 95 and 96:
6. Federal Bank Ltd.7. Jammu & Kash
- Page 97 and 98:
International Competitive BiddingRE
- Page 99 and 100:
CONTENTSRequest for ProposalCMPDISE
- Page 101 and 102:
310208112 (Madh NLW Jan ‘09) IIIS
- Page 103 and 104:
CMPDISECTION Clause No. PARTICULARS
- Page 105 and 106:
CMPDISECTION Clause No. PARTICULARS
- Page 107 and 108:
CMPDIAPPENDICES8 APPENDIXNO.PARTICU
- Page 109 and 110:
SECTION9Plate/ DrawingNo.Plate No-1
- Page 111 and 112:
CMPDI3. PRICE BID (ENVELOPE -3)This
- Page 113 and 114:
Checklist of Documents to be furnis
- Page 115 and 116:
Sl. No.Particulars11 Detailed Imple
- Page 117 and 118:
SECTION - 1(PROJECT OUTLINE)3102081
- Page 119 and 120:
CMPDItransportation of rejects per
- Page 121 and 122:
CMPDIOwner. These provisions shall
- Page 123 and 124:
CMPDIvarious statutory & regulatory
- Page 125 and 126:
CMPDIBidders are free to offer any
- Page 127 and 128:
CMPDIdepartments) besides cost for
- Page 129 and 130:
CMPDIOwner or BOMO in which case th
- Page 131 and 132:
1.7.4 WEIGHING, SAMPLING AND ANALYS
- Page 133 and 134:
CMPDIBCCL at the designated deliver
- Page 135 and 136:
CMPDIplant for a period of ten (10)
- Page 137 and 138:
CMPDIRaw coal shall be supplied at
- Page 139 and 140:
SECTION - 2(GENERAL INFORMATION)310
- Page 141 and 142:
2.5 CLIMATE, RAINFALL AND SEISMIC C
- Page 143 and 144:
SECTION - 3(RAW COAL CHARACTERISTIC
- Page 145 and 146:
3.3 COLLECTION OF SAMPLECMPDIRaw co
- Page 147 and 148:
CMPDIPurpose of investigation : To
- Page 149 and 150:
CMPDI3.5.1.4 CRUSHING OF DESHALED F
- Page 151 and 152:
SolidConcentration%RPMTable - 3.10F
- Page 153 and 154:
3.5.1.12 Balance of ProductTable -
- Page 155 and 156:
CMPDI3.5.2.4 CRUSHING OF DESHALED F
- Page 157 and 158:
CMPDITable - 3.21Wet sieving-cum-As
- Page 159 and 160:
3.5.2.11 WASHING POSSIBILITIES OF R
- Page 161 and 162:
Table - 3.28Screen-cum-Ash Analysis
- Page 163 and 164:
CMPDITable - 3.33Wet sieving-cum-As
- Page 165 and 166:
CMPDI3.5.3.11 BALANCE OF PRODUCT (O
- Page 167 and 168:
SECTION - 4(CONDITIONS OF CONTRACT)
- Page 169 and 170:
CMPDIotherwise obtained from the Ow
- Page 171 and 172:
CMPDI(b) The BOM Operator further g
- Page 173 and 174:
CMPDIdetailed purchase specificatio
- Page 175 and 176:
CMPDIthe time of erection. The BOM
- Page 177 and 178:
CMPDIparties to the contract shall
- Page 179 and 180:
CMPDIfurther extension of time allo
- Page 181 and 182:
CMPDI(b) acts of any government, in
- Page 183 and 184:
a. any reasons defined as Force Maj
- Page 185 and 186:
orCMPDId. shall offer or give or ag
- Page 187 and 188:
CMPDIThe decision of the Owner that
- Page 189 and 190:
CMPDIc. to pay for the materials br
- Page 191 and 192:
CMPDI4(A).21 RELEASE OF INFORMATION
- Page 193 and 194:
CMPDI4(A).26 CO-OPERATION WITH OTHE
- Page 195 and 196:
CMPDI4(A).28.5 In all the above cas
- Page 197 and 198:
CMPDIthe BOM Operator shall in all
- Page 199 and 200:
CMPDI4(A).35.6 The procedure specif
- Page 201 and 202:
4(A).36.5APPLICATION FOR PAYMENTCMP
- Page 203 and 204:
CMPDIpayments linked with despatch
- Page 205 and 206:
CMPDI4(A).36.7.4.2 FOR IMPORTED POR
- Page 207 and 208:
CMPDI4(A).39 SAFETY OF EMPLOYEESThe
- Page 209 and 210:
CMPDI4(A).46 CURRENCIES OF BID & PA
- Page 211 and 212:
CMPDIagency as applicable. However
- Page 213 and 214:
CMPDI4(B).4 ENGINEERING DATA4(B).4.
- Page 215 and 216:
CMPDI4(B).5.7 Further work by the B
- Page 217 and 218:
CMPDI4(B).9.2 Other internationally
- Page 219 and 220:
CMPDIinspection and testing points
- Page 221 and 222:
CMPDInominee giving reasons therein
- Page 223 and 224:
CMPDIthe BOM Operator to the full s
- Page 225 and 226:
CMPDI4(B).17 PRESERVATIVE SHOP COAT
- Page 227 and 228:
CMPDICertificates regarding taking
- Page 229 and 230:
CMPDISECTION - 4 (C)ERECTION CONDIT
- Page 231 and 232:
CMPDIor omissions of another contra
- Page 233 and 234:
CMPDInot cause any delay in the rep
- Page 235 and 236:
CMPDI4(C).14.1 TOOLS, TACKLES AND S
- Page 237 and 238:
CMPDI4(C).17 SECURITYThe BOM Operat
- Page 239 and 240:
CMPDI4(C).21.5 All electrical panel
- Page 241 and 242:
CMPDIchanges on the drawings and ot
- Page 243 and 244:
CMPDIDocument, the following provis
- Page 245 and 246:
CMPDIsubstance or such chemicals wh
- Page 247 and 248:
CMPDIc. obtain permission of the EI
- Page 249 and 250:
CMPDIindividual, the provisions con
- Page 251 and 252:
CMPDI4(C).32.5.2 The grout shall be
- Page 253 and 254:
CMPDI4(C).37.3 Sharp bending and ki
- Page 255 and 256:
SECTION - 4 (D)GENERAL CONDITIONS F
- Page 257 and 258:
CMPDIiv) BCCL will also specify the
- Page 259 and 260:
CMPDI& middlings will be calculated
- Page 261 and 262:
CMPDIOperator to BCCL shall be refu
- Page 263 and 264:
CMPDIapplicable under Cl. No. 4(D).
- Page 265 and 266:
CMPDIii. For balance 25% payment fo
- Page 267 and 268:
CMPDI4(D).5.4 Termination of the Co
- Page 269 and 270:
SECTION - 5 (A)CMPDIMECHANICAL ENGI
- Page 271 and 272:
CMPDI5(A).2.1.1 CONVEYOR FRAMEThe c
- Page 273 and 274:
CMPDIreturn idlers shall be 20 mete
- Page 275 and 276:
CMPDIiv) Bearings & Plummer BlocksA
- Page 277 and 278:
CMPDIrubber 12mm thick, 100mm wide
- Page 279 and 280:
CMPDI5(A).2.1.13 COMPLIANCE WITH ST
- Page 281 and 282:
CMPDI5(A).3.3 The design of the pum
- Page 283 and 284:
CMPDI5(A). 5 LAUNDERS/ TANKS/ SUMPS
- Page 285 and 286:
CMPDIprovided to facilitate mainten
- Page 287 and 288:
CMPDI5(A).8.2 RECIPROCATING FEEDERR
- Page 289 and 290:
CMPDIfouling by unbreakable foreign
- Page 291 and 292:
CMPDIIt shall meet stipulated perfo
- Page 293 and 294:
CMPDIThe bidder shall state the acc
- Page 295 and 296:
CMPDI5(A).20 THREAD SEALINGThread s
- Page 297 and 298:
CMPDIThe bidders are required to fu
- Page 299 and 300:
(d) No. of start per spiral :CMPDI(
- Page 301 and 302:
CMPDI5(A).30 LUBRICATIONPressure lu
- Page 303 and 304:
CMPDIGREAVES COTTON/ REVA ENGG/KANU
- Page 305 and 306:
CMPDI5(A).33.3 All the mechanical &
- Page 307 and 308:
CMPDIg) Supply and installation of
- Page 309 and 310:
CMPDI5(B).5.3 HT SWITCHING STATION-
- Page 311 and 312:
CMPDI5(B).8 GENERAL EARTHING & EART
- Page 313 and 314:
CMPDI5(B).10.2 General Illumination
- Page 315 and 316:
CMPDIimplementing specific function
- Page 317 and 318:
CMPDIproducts produced from the was
- Page 319 and 320:
vii) Sagging & tensioning of conduc
- Page 321 and 322:
CMPDIafter vacuum drying to ensure
- Page 323 and 324:
CMPDIThe thermometer pocket shall b
- Page 325 and 326:
CMPDIc) The insulation of transform
- Page 327 and 328:
CMPDIb) Cable boxes shall be with t
- Page 329 and 330:
CMPDIleast four (4) weeks advance n
- Page 331 and 332:
Sl.DescriptionRatingNo.21 a) Temper
- Page 333 and 334:
CMPDISystem Earthing : Effectively
- Page 335 and 336:
CMPDIcompartment and cable alley ma
- Page 337 and 338:
CMPDImaterial. The gland plate shal
- Page 339 and 340:
CMPDItransformers shall be run thro
- Page 341 and 342:
CMPDIdiscontinuity to other devices
- Page 343 and 344:
CMPDIe) Circuit breakers shall be p
- Page 345 and 346:
CMPDIpositions marked “Switchgear
- Page 347 and 348:
CMPDIAll AC relays shall be suitabl
- Page 349 and 350:
CMPDIAll internal wiring will be ca
- Page 351 and 352:
CMPDISl No. Item Description14 Cate
- Page 353 and 354:
CMPDIf) Earthing - All equipment sh
- Page 355 and 356:
CMPDI5(B).19.4.5 INDICATIONElectric
- Page 357 and 358:
CMPDI6. Frequency : 50 Hz (-5% to +
- Page 359 and 360:
CMPDIAny material and component not
- Page 361 and 362:
CMPDIEquipment complying with other
- Page 363 and 364:
CMPDIFor supply, erection and commi
- Page 365 and 366:
CMPDIUn-vulcanized rubber or Thermo
- Page 367 and 368:
CMPDINothing in this specification
- Page 369 and 370:
CMPDIconstruction capable of clampi
- Page 371 and 372:
c) Earthingeffectively earthedd) Hi
- Page 373 and 374:
CMPDIAltitude - Maximum upto 1000 m
- Page 375 and 376:
CMPDI5(B).19.10.7 VIDEO DISPLAY UNI
- Page 377 and 378:
CMPDI5(B).19.11.2.2 ACTUATORPower :
- Page 379 and 380:
CMPDI+/- 0.5% ash in typical washed
- Page 381 and 382:
CMPDIfacility. All pull chord switc
- Page 383 and 384:
CMPDIEach pit shall be provided wit
- Page 385 and 386:
CMPDIThe branch distribution boards
- Page 387 and 388:
CMPDIIn the event of fault, if faul
- Page 389 and 390:
CMPDISize of earth bus : 90 sq. mm
- Page 391 and 392:
CMPDI10. Terminals : To take PVCSWA
- Page 393 and 394:
CMPDIsulphuric paint and complete w
- Page 395 and 396:
CMPDId) Detailed design drawings sh
- Page 397 and 398:
Sl No. Item DescriptionName of the
- Page 399 and 400:
Sl No. Item DescriptionName of the
- Page 401 and 402:
CMPDIg) Drainage/ Sewage from vario
- Page 403 and 404:
CMPDIindicative in nature and exclu
- Page 405 and 406:
CMPDI5(C).3.2 PLATFORM AND RAMP ARO
- Page 407 and 408:
CMPDItypes of soil and rock. The sl
- Page 409 and 410:
CMPDIhave brick walls in cladding w
- Page 411 and 412:
CMPDIbe provided with suitable line
- Page 413 and 414:
CMPDIsuitable toilet facilities and
- Page 415 and 416:
CMPDI5(C).4.9 SECURITY CHECK POST C
- Page 417 and 418:
CMPDIprovided depending on site con
- Page 419 and 420:
CMPDI5(C).7.3 PIPESThe scope also c
- Page 421 and 422:
CMPDIassembly. The drawings shall b
- Page 423 and 424:
CMPDI5(C).11.1 The BOMO shall const
- Page 425 and 426:
CMPDI5(C).11.11 The inspection of c
- Page 427 and 428:
CMPDI5(C).11.20 Steel doors, window
- Page 429 and 430:
CMPDIshall be removed from site imm
- Page 431 and 432:
CMPDIand shall conform to IS:383 .
- Page 433 and 434:
CMPDIdimensions of the frame pieces
- Page 435 and 436:
CMPDI5(C).11.29.8.18CEMENT MORTARCe
- Page 437 and 438:
CMPDIreceived and consumed shall be
- Page 439 and 440:
CMPDI5(C).11.29.9.7 ROOFING MATERIA
- Page 441 and 442:
CMPDI5(C).11.30 WORKMANSHIP5(C).11.
- Page 443 and 444:
CMPDIIn case blasting is required,
- Page 445 and 446:
CMPDI(table 9). The concrete grade
- Page 447 and 448:
CMPDIShuttering shall be of steel p
- Page 449 and 450:
CMPDIAll reinforcement shall immedi
- Page 451 and 452:
CMPDIsurface water and shocks. Conc
- Page 453 and 454:
CMPDIPre-cast concrete planks after
- Page 455 and 456:
CMPDIper M² in case of coal tar an
- Page 457 and 458:
CMPDImade available by the BOMO to
- Page 459 and 460:
CMPDINominal Bolt Dia (mm) Minimum
- Page 461 and 462:
CMPDI5(C).11.30.3.9MARKING AND DISP
- Page 463 and 464:
CMPDIThe BOMO shall take care to se
- Page 465 and 466:
CMPDIthe courses shall be kept perf
- Page 467 and 468:
CMPDId) FinishGenerally the standar
- Page 469 and 470:
CMPDIcolour shall be as per paintin
- Page 471 and 472:
CMPDImanufacturer's direction. Any
- Page 473 and 474:
CMPDI5(C).11.30.6.6 CLEANING UPThe
- Page 475 and 476:
CMPDI5(C).11.30.7.3 PLAIN & COLOURE
- Page 477 and 478:
CMPDI5(C).11.30.7.6 PVC TILE FLOORI
- Page 479 and 480:
CMPDIbigger sizes shall be of reduc
- Page 481 and 482:
CMPDIvi) All windows shall be glaze
- Page 483 and 484:
CMPDIBrass sliding bolts shall be m
- Page 485 and 486:
CMPDIinsulation and allied works fo
- Page 487 and 488:
CMPDIgrade-l, of approved make.(iii
- Page 489 and 490:
CMPDIworks, such as connections, ma
- Page 491 and 492:
CMPDIbedding and packing is the bes
- Page 493 and 494:
CMPDImanhole or inspection chamber
- Page 495 and 496:
CMPDIspigot and the cast iron socke
- Page 497 and 498:
CMPDIIt shall be made of glazed sto
- Page 499 and 500:
CMPDIbe inspected on site before la
- Page 501 and 502:
CMPDImanufacturers in time, so that
- Page 503 and 504:
CMPDIiii) ContaminationThere shall
- Page 505 and 506:
CMPDISocket and spigot ended pipes
- Page 507 and 508:
CMPDIrising main shall be connected
- Page 509 and 510:
CMPDIas well, suitable footholds sh
- Page 511 and 512:
CMPDI5(C).12.8.2 Those engaged in w
- Page 513 and 514:
CMPDI5(C).12.11.7 When workers are
- Page 515 and 516:
CMPDIdamp proofingIS: 1566 - Specif
- Page 517 and 518:
CMPDIIS: 1361 - Steel windows for i
- Page 519 and 520:
IS: 458 - Concrete pipes (with & wi
- Page 521 and 522:
SECTION - 5 (D)CMPDIPERFORMANCE GUA
- Page 523 and 524:
CMPDI- Hourly Capacity : ………
- Page 525 and 526:
CMPDIThe Bidder shall furnish/ conf
- Page 527 and 528:
CMPDIv) Screena) Coarse screening (
- Page 529 and 530:
CMPDIxi) Horizontal Travelling Vacu
- Page 531 and 532:
CMPDIFailing to prove the above gua
- Page 533 and 534:
5(D).4.2.4 HM CycloneCMPDIGuarantee
- Page 535 and 536:
CMPDIFor Dewatering Equipment for f
- Page 537 and 538:
SECTION - 6(PRICE BID)310208112 (Ma
- Page 539 and 540:
CMPDIe) Instructions (for Bidders a
- Page 541 and 542:
CMPDI6.2.4 In case of overseas supp
- Page 543 and 544:
Table - 6.3CMPDIC. Cost towards Ind
- Page 545 and 546:
CMPDI6.3.6 PROJECT IMPORT DUTIES BE
- Page 547 and 548:
CMPDIagreed before signing of the C
- Page 549 and 550:
CMPDIdifferent bidders. However, bi
- Page 551 and 552:
CMPDI6.10 PRICE VARIATION6.10.1 The
- Page 553 and 554:
CMPDIL = Revised minimum wages of u
- Page 555 and 556:
CMPDIfrom this amount the value of
- Page 557 and 558:
CMPDIregistration, statutory inspec
- Page 559 and 560:
CMPDISECTION - 7SAMPLE CONTRACT FOR
- Page 561 and 562:
CMPDIthe option of further renewal
- Page 563 and 564:
CMPDICompany’s Stamp/ Seal : Comp
- Page 565 and 566:
CMPDIAPPENDIX - 1 AFORMAT FOR FURNI
- Page 567 and 568:
CMPDIAPPENDIX-2AGraph showing Guara
- Page 569 and 570:
APPENDIX-2B(Contd.)YIELD % OF MIDDL
- Page 571 and 572:
CMPDIAPPENDIX - 4DESCRIPTION OF PRO
- Page 573 and 574:
CMPDIAPPENDIX - 6FORMAT FOR FURNISH
- Page 575 and 576:
CMPDIAPPENDIX - 8FORMAT FOR FURNISH
- Page 577 and 578:
CMPDIAPPENDIX - 10AFORMAT FOR FURNI
- Page 579 and 580:
CMPDIAPPENDIX - 10BFORMAT FOR FURNI
- Page 581 and 582:
CMPDIAPPENDIX - 12(A)Bidder i.e. Le
- Page 583 and 584:
CMPDIthe Bid Documents/ specificati
- Page 585 and 586:
CMPDIthe Owner. The value of such F
- Page 587 and 588:
CMPDIAPPENDIX - 12(B)Bidder i.e. Le
- Page 589 and 590:
CMPDIThe role, tenure & % stake of
- Page 591 and 592:
CMPDIworks or at its Vendor's works
- Page 593 and 594:
ASSOCIATE(S)CMPDIFor and on behalf
- Page 595 and 596:
administrators, executors and assig
- Page 597 and 598:
CMPDIshall be required to furnish t
- Page 599 and 600:
CMPDI6.0That this Deed will form an
- Page 601 and 602:
CMPDIAPPENDIX - 14Bidder seeking Qu
- Page 603 and 604:
CMPDIor other guarantee that Owner
- Page 605 and 606:
CMPDI1 We, ........................
- Page 607 and 608:
CMPDIAPPENDIX - 15 (B)Bidder (Lead
- Page 609 and 610:
CMPDIwithstanding any security or o
- Page 611 and 612:
CMPDI1. We, .......................
- Page 613 and 614:
To,CMPDIAPPENDIX - 17 (A)Bidder (Le
- Page 615 and 616:
CMPDIArbitrator or any other Author
- Page 617 and 618:
To,CMPDIAPPENDIX - 17 (B)Bidder (Le
- Page 619 and 620:
CMPDIThe Bank shall not be released
- Page 621 and 622:
CMPDIAPPENDIX - 18FORMAT FOR DETAIL
- Page 623 and 624:
ItemNo.Sub-heads/ Item DescriptionQ
- Page 625 and 626:
C. PRICE BREAK UP OF PLANT & MACHIN
- Page 627 and 628:
C.1 - SUPPLY OF PLANT & MACHINERY :
- Page 629 and 630:
C.1 - SUPPLY OF PLANT & MACHINERY :
- Page 631 and 632:
CMPDIC.2 - ERECTION, INSTALLATION &
- Page 633 and 634:
CMPDID. WEIGHT & VOLUME FOR CIVIL &
- Page 635 and 636:
FORMAT FOR FURNISHING SUMMARY OF CA
- Page 637 and 638:
CMPDIIt is preferred for the bidder
- Page 639 and 640:
PLATE NO. : 1Colliery/ Mine : Murai
- Page 641 and 642:
PLATE NO. : 3Colliery/ Mine : Block
- Page 643 and 644:
PLATE NO. : 5Colliery/ Mine : Murai
- Page 645:
SITE PLAN SHOWING LAND USE OF EXIST
- Page 650 and 651:
CMPDIENCLOSURE - 1FORMAT FOR DCF AN
- Page 652 and 653:
CMPDIENCLOSURE - 2The soil investig
- Page 654 and 655:
CMPDI3.0 THE GEOLOGYcategories:-The
- Page 656 and 657:
CMPDI4.0 THE FIELD WORK AND SUB-SUR
- Page 658 and 659:
CMPDI5.0 THE LABORATORY INVESTIGATI
- Page 660 and 661:
5. Direct Shear Test6. Chemical Ana
- Page 662 and 663:
CMPDIadequate simulation that provi
- Page 664 and 665:
CMPDIb) The amount of water which m
- Page 666 and 667:
CMPDIb) In general the chemical par
- Page 668 and 669:
CMPDIiv) Porosity -a) Code referenc
- Page 670 and 671:
CMPDIsteel platens and sorted out b
- Page 672 and 673:
CMPDI6.0 SUBSURFACE PROFILEObservin
- Page 674 and 675:
CMPDI7.0 DISCUSSIONObserving the su
- Page 676 and 677:
35.0x35.0 2.00 297940.0x40.0 2.00 2
- Page 678 and 679:
BOREHOLE DATA SHEETLOCATION - MADHU
- Page 680 and 681:
CMPDIBorehole 4 CoordinateCommenced
- Page 682 and 683:
LABORATORY TEST RESULTSCMPDISl.No.B
- Page 684 and 685:
SOIL PROFILELAYER I Top soil, consi
- Page 686:
SOIL PROFILELAYER I Soft to firm,br