accessories_expansion cards• Ethernet• Profibus DP• LONbus• Analog output• Digital output• Digital input_com serverexternal module for connecting themeasuring devices from RS485/232to Ethernet communication_bip moduleexternal module for connecting the measuringdevices from RS485 or pulses to Profibus DPcommunication_DEDALO ® evaluation and parameterizing software• For Windows 200/XP/2003/2007/Vista/7• User-friendly operation• Single and multi-user versionThe Dedalo software package supports data communication between a PCand the BERG grid monitoring modules of the series UBN 30, 304, 307, 310, 315,3060, 3080 and 3100. With Dedalo the operating parameters of the grid monitoringmodules can be set and all measured quantities can be read out, displayed on thescreen and saved as a measuring series from the PC.The software is available in two different versions:• DEDALO SP: Software for point-to-point read out• DEDALO NET: Software for the simultaneous displayof up to 512 UBN measuring devices.Available as a workstation or as a client-server version_functionality• Real time monitoring and trend display• Memory export and logging• Remote parameterization of measuring devices• Alarm management and threshold setting• Visualization via ANALYSIS• Export functionBoth software versions can be expandedvia remote access quickly and flexibly.<strong>Berg</strong> GmbHFraunhoferstr. 22 | 82152 Martinsried | GermanyTel.: 0049 (0) 89/379160-0 | Fax: 0049 (0) 89/379160-199homepage: www.berg-energie.de | email: info@berg-energie.de


universal <strong>Berg</strong> <strong>network</strong> <strong>analyzer</strong>overviewuniversal <strong>Berg</strong> <strong>network</strong> <strong>analyzer</strong> for building automation,industrial control and protection technologyWith Ethernet, Modbus RTU/TCP, OPC, LONbus or Profibus DP<strong>Berg</strong> – the energy optimizer


Standard equipmentOptionx not availablemodel/series UBN 30 UBN 304 UBN 307 UBN 310Installation/Dimensions DIN rail / Control panel Control panel Control panel6 pitches 96 x 96 mm 96 x 96 mm 96 x 96 mmMeasuring functionsAll UBNs (universal grid monitoring modules)are equipped with the following measuringfunctions: Phase voltages [V], phase currents [A]including neutral wire, avtive power [kW],apparent power [kVA], reactive power [kVAr],power factor [PF], system frequency [Hz],active energy [kWh] and reactive energy[kVArh]Four-quadrant <strong>measurement</strong> of active,reactive, delivery and supplyxAveraging over settable periodExtreme value memoryHarmonic distortion of voltage and current x xHarmonics analysis up to 31st harm. For U, I x xPhase rotary field displayMemory functionMemory type RAM 128 kB EEPROM EEPROM RAM 128 kBIntegrated real time clockxOutputsPhotoMOS potential-free (max. number) (2) x x (6)analog 0(4) ... 20 mA (max. number) x x x (4)Transistor (max. number) x (2) (2) xInterfacesRS485 field busRS232 PC, modemEthernet LAN (internal or external) (external) (external) (external)ProtocolsBERG ASCII busModbus (RTU) (RTU) (RTU) (RTU)LONbus (internal) x x xProfibus DP (internal)(external always possible with BIP module) x xTechnical dataVoltage input (max. overload*) 750 V L-L (2 kV) 750 V L-L (2 kV) 750 V L-L (2 kV) 750 V L-L (2 kV)Current input (max. current input) 1 // 5 A (7 A) 1 // 5 A (7 A) 1 // 5 A (7 A) 1 // 5 A (7 A)Frequency measuring range 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 HzAccuracy (percentage ± 1 digit) I: 0,2%, U: 0,2%, I: 0,2%, U: 0,2%, I: 0,2%, U: 0,2%, I: 0,1%, U: 0,2%,P: 1% P: 1% P: 1% P: 0,5%Power supply 230 VAC/115 VAC 230 VAC/115 VAC 230 VAC/115 VAC 19 ... 250 VACPower consumption 1,5 VA 1,5 VA 2 VA max. 5 VAOperational temperature** -10 °C ... +50 °C -20/-10 °C ... -20/-10 °C ... -20/-10 °C ...+60/+75 °C +60/+50 °C +60/+75 °CDimensions (W x H x D) 106 x 90 x 57 96 x 96 x 60 96 x 96 x 60 96 x 96 x 130Housing Plastic Plastic Plastic Metal housing* occurring overload up to max. 1 sec. duration ** LCD devices can only be used in a narrow temperature range.Subject to change without notice


UBN 315 UBN 400E UBN 3060 UBN 3080 UBN 3100 UBN 6100Control panel Control panel Control panel Control panel Control panel Mobile grid96 x 96 mm 96 x 96 mm 144 x 144 mm 144 x 144 mm 144 x 144 mm monitoring case(optional so)(so)RAM 128 kB EEPROM RAM 128 kB RAM 128 kB RAM 2 MB 4 MB(6) (2) (6) (6) (6 (1))(4) (2) (4) (4) (4) (1)x x x x x xx(RTU) (TCP) (RTU) (RTU) (RTU) xxx750 V L-L (2 kV) 750 V L-L (2 kV) 750 V L-L (2 kV) 750 V L-L (2 kV) 750 V L-L (2 kV) 750 V L-L (2 kV)1 // 5 A (7 A) 1 // 5 A (7 A) 1 // 5 A (7 A) 1 // 5 A (7 A) 1 // 5 A (7 A) 1 // 5 A (7 A)45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 HzI: 0,1%, U: 0,2%, I: 0,25%, U: 0,25%, I: 0,1%, U: 0,1%, I: 0,1%, U: 0,1%, I: 0,2%, U: 0,2%, I: 0,2%, U: 0,2%,P: 0,5% P: 0,5% P: 0,5% P: 0,5% P: 1% P: 1%19... 250 VAC 19 ... 35 VDC / 85 19 ...250 VAC 19 ...250 VAC 19 ...250 VAC 85 ... 250 VAC oder... 265 VAC 110 … 250 VDCmax. 8 VA max. 6 VA max. 5 VA max. 5 VA max. 8 VA max. 30 VA-20/-10 °C ... -10 °C ... +50 °C -20/-10 °C ... -20/-10 °C ... -10 °C ... +75 °C -5 °C ... +55 °C+60/+75 °C +60/+75 °C +60/+75 °C96 x 96 x 130 96 x 96 x 90 144 x 144 x 95 144 x 144 x 95 144 x 144 x 118 420 x 340 x 210Metal housing Metal housing Metal housing Metal housing Metal housing Plastic<strong>Berg</strong> – the energy optimizer