13.07.2015 Views

Download 33kv Copper Cables Brochure - Prysmian

Download 33kv Copper Cables Brochure - Prysmian

Download 33kv Copper Cables Brochure - Prysmian

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MEDIUM VOLTAGE CABLES<strong>Copper</strong>19/33kVPhysical & Electrical CharacteristicsProduct Code3CCUX33LDNominal ConductorArea mm 2 50 70 95 120 150 185 240 300Nominal ConductorDiameter mmNominal InsulationThickness mmApprox CableDiameter mm8.2 9.8 11.5 12.9 14.3 16.1 18.2 20.68.0 8.0 8.0 8.0 8.0 8.0 8.0 8.068.5 72.4 76.3 79.5 82.7 86.7 91.8 97.6Approx Mass kg/100m 435 525 620 715 810 940 1140 1350Max Pulling TensionOn Conductors kNMax Pulling TensionOn Stocking Grip kNMin Bending Radius*:During Installation mmMin Bending Radius*:Set In Position mmMax ConductorResistance, dc @ 20°COhm/kmConductor Resistance,ac @ 90°C & 50 HzOhm/km11 15 20 25 25 25 25 2511 15 20 22 24 25 25 251230 1300 1370 1430 1490 1560 1650 1760820 870 920 950 990 1040 1100 11700.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.06010.494 0.342 0.247 0.196 0.159 0.128 0.0978 0.0788Inductance mH/km 0.457 0.422 0.401 0.384 0.371 0.358 0.344 0.332Inductive Reactance,@ 50Hz Ohm/kmZero Seq. Impedance@ 20°C & 50 HzOhm/kmCapacitance, PhaseTo Earth µF/kmMin InsulationResistance @ 20°CMOhm.kmElectric Stress AtConductor ScreenkV/mmCharging Current @Rated Voltage & 50 HzA/phase/kmShortCircuitRatingContinuousCurrentRatingPhaseConductorkA, 1 secMetallicScreenkA, 1 secIn Ground,Direct BuriedAIn Ground,In SinglewayDuctsAIn Free Air,Unenclosed& SpacedFrom WallA0.143 0.133 0.126 0.121 0.117 0.112 0.108 0.1042.32+j0.0978 2.09+j0.0871 1.92+j0.0805 1.79+j0.0752 1.69+j0.0714 1.59+j0.0672 1.44+j0.0629 1.37+j0.05930.140 0.155 0.171 0.184 0.197 0.212 0.232 0.25518,000 16,000 15,000 14,000 13,000 12,000 11,000 9,9004.07 3.85 3.67 3.55 3.46 3.36 3.26 3.160.834 0.927 1.02 1.10 1.17 1.27 1.39 1.527.2 10.0 13.6 17.2 21.5 26.5 34.3 42.94.3 4.6 4.8 5.1 5.3 5.6 6.1 6.3190 235 280 320 365 410 484 545170 210 245 280 310 355 401 452195 245 295 340 390 440 544 620The cables described in this technical manual are designed to be used for the supply of electrical energy in fixed applications up to the rated voltages at a nominal power frequency between 49Hz and 61Hz.*Increased radius required for HDPE and nylon incorporating designs.113

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!