Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Copyright © 2011 Tonica Elektronik A/S. All rights reserved.The contents of this manual are the property of Tonica Elektronik A/S.Any reproduction in whole or in part is strictly prohibited.Tonica Elektronik A/S has a continued development of its products. Tonica Elektronik A/S reservesthe right to change and improve the products described in this document. Furthermore TonicaElektronik A/S reserves the right to make changes to this document at any time without previouswarning.At the time of printing, this manual correctly described the device and its functions. However, asmodifications may have been carried out since the production of this manual, the system packagemay contain one or more addenda to the manual. This manual including any such addenda must bethoroughly read, before using the device.The following situations void any guarantee(s) and obligations for Tonica Elektronik A/S:- The device is not used according to the enclosed manuals and other accompanyingdocumentation- The device is installed or modified by persons other than Tonica Elektronik A/S or otherauthorized service technicians2 www.<strong>MagVenture</strong>.com


ContentsMagnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Introduction ............................................................................................................. 5Selection Criteria for Magnetic Stimulating Coils ..................................................................................... 5General Information ............................................................................................... 6Environment ............................................................................................................................................. 6Intended use ............................................................................................................................................ 6Contraindications ..................................................................................................................................... 6General Warnings .................................................................................................................................... 6Operating period (Coils) ........................................................................................................................... 7Range of Coils .......................................................................................................................................... 8Magnetic stimulator overview ................................................................................................................... 9Symbols and Warnings .......................................................................................... 10Symbols ................................................................................................................................................. 10Classification .......................................................................................................................................... 10Encapsulation of Coils ........................................................................................................................... 10EMC and Interference ............................................................................................................................ 10Maintenance and Waste Management ................................................................. 10Daily ....................................................................................................................................................... 10Waste Management ............................................................................................................................... 10Standard Coils........................................................................................................ 11C-100 Circular Coil with power control................................................................................................... 11C-B60 Butterfly Coil with power control ................................................................................................. 12MC-B35 Butterfly Coil ............................................................................................................................ 13MC-B70 Butterfly Coil ............................................................................................................................ 14MC-125 Circular Coil .............................................................................................................................. 15MMC-140 Parabolic Coil ........................................................................................................................ 16MMC-140-II Parabolic Coil with power control ....................................................................................... 17RT-120 Racetrack Coil ........................................................................................................................... 18RT-120-II Racetrack Coil with power control ......................................................................................... 19D-B80 Butterfly Coil ............................................................................................................................... 20MC-B65-HO-2m and 8m Butterfly Coils ................................................................................................. 21Static Cooled Coils ................................................................................................. 22MCF-B65 Butterfly Coil .......................................................................................................................... 22MCF-B70 Butterfly Coil .......................................................................................................................... 23MCF-75 Circular Coil.............................................................................................................................. 24MCF-125 Circular Coil ........................................................................................................................... 25Dynamic Cooled Coils ........................................................................................... 26Cool-B35 Butterfly Coil ........................................................................................................................... 26Cool-B65 Butterfly Coil ........................................................................................................................... 27Cool-B70 Butterfly Coil ........................................................................................................................... 28Cool D-B80 Butterfly Coil ....................................................................................................................... 29Cool-125 Circular Coil ............................................................................................................................ 30Coil Cooler Unit ...................................................................................................................................... 31MRi Coil System .................................................................................................... 32MRi-B90 II Butterfly Coil ......................................................................................................................... 32Research Coils ....................................................................................................... 33MC-P-B70 Placebo Butterfly Coil ........................................................................................................... 33www.<strong>MagVenture</strong>.com 3


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>GeneralInformationEnvironmentThe devices have been designed for indooruse at operating ambient temperatures rangingfrom +10°C to +30°C (from +50°F to +86°F).The storage temperature is ranging from 0°Cto 50°C (+32°F to +120°F).The operating ambient humidity is rangingfrom RH 40% to 70%. Storage humidity fromRH 10% to 90%The coils have a thermo sensor, which turnsthe stimulator off, when the coil surfacereaches a temperature of 41°C (106°F).Intended useSee the accompanying documentation and theUser Guide for the magnetic stimulatordevice.ContraindicationsSee the accompanying documentation and theUser Guide for the magnetic stimulatordevice.General WarningsSee the accompanying documentationand carefully read the followingwarningsWarnings• Do not use this equipment for anything elsethan it is intended for by the manufacturer.• The device is not compatible for use in anMR magnetic field. Please consult themanufacturer for available special solutionssuch as the MRi-B90 II system.• Rapid cortical stimulation can induceseizures. Ensure that appropriate safetymeasures are taken, before using theequipment.• To protect patients from excessiveexposure to magnetic gradients keep thenumber of stimulations as low as possible.• The device is not intended for use withanesthetic gases or any other flammablemedia – danger of electrical ignition.• The operator must be protected againstlong-term magnetic fields (e.g. by using aholding device as the Flexible Arm).• Hearing protection is recommended if thecoil is used near the head or whenoperating with more than 100 stimuli aday.• Not to be used on small children.• Keep out of reach of children.• Precautions should be taken whenstimulating patients with suspected ordiagnosed labile or hypertensive bloodpressure.• The field produced by this device candamage a cochlear implant, cardiacpacemaker and implanted electronicdevices.• The MagPro must only be used under theconstant supervision of qualified medicalpersonnel, only on patients who are notanaesthetized and only for short term use.6 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cautions• Before connecting, please read theinstructions for use.• Always carefully examine the coil handle,housing and cables for cracks, marks,deformations, color changes and othersigns of damage before using it. Do not usethe coil if there is any evidence of stressfailure; otherwise it may disintegrate.• Metallic (conductive) objects in the fieldmay be propelled forcibly by the stimuluspulse. Make sure there are no rings, coinsor similar metal objects near the coil whenit is activated.• Do not place the stimulation coil on ornear: video monitors, watches, calculators,credit cards, or computer disks. Damage orerasure may occur.• Disable the device when it is not beingused by pressing the Enable/Disable buttonon the magnetic stimulator.• Before changing the stimulation coil, pressDisable on the magnetic stimulator toavoid damage to personnel and equipment.• Always use the Flexible Arm to hold theMagnetic Stimulation Coils of Fluid- orCool types during stimulations.• Changes in noise level or sound frequencyfrom the coil during stimulation mayindicate beginning damages inside the coil.Stop using the coil and contact a ServiceCenter; otherwise it may disintegrate.• The coil must not be submersed into anyconductive liquid, including water.The encapsulation tolerates low levels ofsurface moist - but in general care shouldbe taken to keep all surfaces clean anddry.• The coils and other accessories are for usewith <strong>MagVenture</strong> magnetic stimulatorsonly.Operating period (Coils)DangerDue to the mechanical and thermal stressduring stimulation, Magnetic StimulatingCoils must not be used after the expirationdate.The expiration date is shown on the label,which is situated on top of the large orangecoil connector, as YYYY-MM-DD.All Cool-Coils have a built in timer andcounter with preset operating period (days andstimulations).Maximum operating period for the coils:Coil typeC-100C-B60MC-B35MC-125MC-B70MMC-140MMC-140-IIRT-120RT-120-IIMC-B65-HOD-B80MC-P-B70MCF-B65MCF-B70MCF-75MCF-125MCF-P-B65Cool-B35*Cool-B65Cool-B70Cool D-B80Cool-125Cool-B65 A/PMRi-B90 IICustomdesigned coilsMaximum operatingperiod5 years3 years5 years ormax. 18.000.000 EPV*max. 2.000.000 EPV(see separate User Guidefor Cool coils)2 yearsSee separate datasheetswww.<strong>MagVenture</strong>.com 7


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Range of Coils<strong>MagVenture</strong> is supporting a wide range of coils in 3 basic designs; standard, static cooled anddynamic cooled types.Across these basic designs the magnetic field is similar for different families of coils. These areindicated with a blue horizontal line in figure below.8 www.<strong>MagVenture</strong>.com


Magnetic stimulator overviewMagPro R30MagPro X100MagPro R100MagPro CompactPart no. Coil type SW support from SW support from Supported9016E0401 MCF-B70 5.0.0 Yes with converter9016E0413 MCF-125 0.97 1.0.3 Not recommended9016E0423 MCF-B65 0.97 1.0.3 Not recommended9016E0431 D-B80 0.97 1.0.3 Yes with converter9016E0442 MCF-75 3.21 1.0.3 Not recommended9016E0462 MC-B65-HO-2 0.97 1.0.3 Yes with converter9016E0472 MC-B65-HO-8 0.97 1.0.3 Yes with converter9016E0482 C-B60 0.97 1.0.3 Yes9016E0491 Cool-B65 3.22 1.0.3 Not recommended9016E0501 Cool-B65 A/P 5.0.0 / 5.2.0 * Not recommended9016E0511 Cool-125 5.0.0 Not recommended9016E0521 Cool-B70 5.0.0 Not recommended9016E0531 Cool D-B80 5.0.1 Not recommended9016E0555 MC-125 0.97 1.0.3 Yes with converter9016E0564 MC-B70 0.97 1.0.3 Yes with converter9016E0573 MMC-140 0.97 1.0.3 Yes with converter9016E0582 C-100 0.97 1.0.3 Yes9016E0592 MC-P-B70 0.97 1.0.3 Yes with converter9016E0601 MCF-P-B65 0.97 1.0.3 Not recommended9016E0631 MMC-140-II 0.97 1.0.3 Yes9016E0641 RT-120 0.97 1.0.3 Yes with converter9016E0651 RT-120-II 0.97 1.0.3 Yes9016E0661 MRi-B90 II 5.2.0 No9016E0671 MC-B35 5.0.1 Yes with converter9016E0681 Cool-B35 5.2.0 Not recommended*) Cool-B65 A/P:Support for real double blinded studies requires MagPro software version 5.2.0 or newer and specialResearch PC program - MagLink (9016S0121) for study setup.


Symbols andWarningsSymbolsSN xxxP/NThe device complies with the EC directive93/42/EEC on medical devicesThe device is of Type BF, i.e. the appliedpart is electrically isolated.Indicates the current direction on coilsStorage temperature range. Packaging labelSerial Number.Part NumberWaste Electrical and Electronic Equipment:Compliance information.User information: Do not dispose of thisproduct in the unsorted municipal wastestream. Dispose of this product according tolocal regulations.CAUTION Electric shock hazard. Do notremove the cover. The coils are notserviceable by the user. Please contact aService Center (please see the back of thiscatalogue for further details).ClassificationMagnetic Coils.IEC 60601-1, IP24EMC and InterferenceWARNING Electrical equipment for medicaluse requires special EMC precautions andneeds to be installed and serviced according tothe EMC documentation of the main device.Maintenance andWasteManagementDailyAfter use, clean the coil with normaldishwashing liquids, and then disinfect it withpropyl alcohol, isopropyl alcohol, or ethylalcohol.The enclosure material can withstand atemperature of 50°C for cleaning anddisinfecting.Check the coil for damages, cracks, marks,deformations, color changes and otherirregularities. Do not use the coil if there isany evidence of stress failure and contact aService Center.Waste ManagementThe device and its accessories must bedisposed of separately as electronic wasteaccording to local regulations.See compliance information in the symbolssection.Encapsulation of CoilsMinimum 2mm plastic material. Windings areplaced symmetrically in horizontal planeinside the encapsulation.


Standard CoilsMagnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>C-100 Circular Coil with power controlMechanical PropertiesWeight of transducer head 0.6kgDimensions of transducer head ø123 x 11.5 mmCable length 1.7mCoil Winding DataInner diameter20mmOuter diameter110mmWinding height6mmNumber of windings 14Magnetic and Electrical PropertiesMax initial dB/dt35 kT/s near the coilsurface.Active pulse width280μs (Biphasic)PerformanceNumber of stimulations before 400 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E058-• The coil is suitable for general-purposestimulation.• Equipped with power control and triggerbutton to support clinical operation.www.<strong>MagVenture</strong>.com 11


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>C-B60 Butterfly Coil with power control• The coil is suitable for focusedstimulations.• Equipped with power control and triggerbutton to support clinical operation.Mechanical PropertiesWeight of transducer head 0.7kgCable length 1.7mDimensions of transducer head 165 x 85 x 19 mmCoil Winding DataInner diameter35mmOuter diameter75mmWinding height11mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt35 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before 350 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E048-12 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MC-B35 Butterfly Coil• The coil handle is placed orthogonal to thecoil surface.• The coil is suitable for focused stimulationof peripheral nerves and muscles.• Compact design• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 0.6kgCable length 1.5mDimensions of transducer head 103 x 55 x 18 mmCoil Winding DataInner diameter24mmOuter diameter47mmWinding height9mmNumber of windings 2x (3 x 4)Magnetic and Electrical PropertiesMax initial dB/dt50 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 75 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Numbers 9016E067-www.<strong>MagVenture</strong>.com 13


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MC-B70 Butterfly CoilMechanical PropertiesWeight of transducer head 1.1kgCable length 1.7mDimensions of transducer head 169 x 112 x 16/33 mmAngle 150°Coil Winding DataInner diameter25mmOuter diameter97mmWinding height6mmNumber of windings 2 x 10Magnetic and Electrical PropertiesMax initial dB/dt31 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 400 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E056-• The coil is suitable for focused stimulation.• The coil is produced with a slight bendsurface to closely follow the shape of thehead.• Equipped with trigger button to supportclinical operation.14 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MC-125 Circular Coil• The coil is suitable coil for general purposestimulation.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 0.6kgCable length 1.3mDimensions of transducer head ø130 x 11.3 mmCoil Winding DataInner diameter28mmOuter diameter114mmWinding height6mmNumber of windings 13Magnetic and Electrical PropertiesMax initial dB/dt41 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before 450 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E055-www.<strong>MagVenture</strong>.com 15


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MMC-140 Parabolic CoilMechanical PropertiesWeight of transducer head 0.8kgCable length 1.5mDimensions of transducer head ø143 x 14.5/33 mmCoil Winding DataInner diameter25mmOuter diameter120mmWinding height6mmNumber of windings 14Magnetic and Electrical PropertiesMax initial dB/dt33 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 650 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E057-• The coil is parabolic in shape to provide apowerful and focused stimulation.• Equipped with trigger button to supportclinical operation.16 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MMC-140-II Parabolic Coil with power control• The coil is parabolic in shape to provide apowerful and focused stimulation.• Equipped with power control and triggerbutton to support clinical operation.Mechanical PropertiesWeight of transducer head 0.9kgCable length 2.5mDimensions of transducer head ø143 x 17/39 mmCoil Winding DataInner diameter25mmOuter diameter126mmWinding height6mmNumber of windings 15Magnetic and Electrical PropertiesMax initial dB/dt33 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 650 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E063-www.<strong>MagVenture</strong>.com 17


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>RT-120 Racetrack Coil• The coil is elliptic in shape and isespecially suitable for stimulation of widerareas such as bigger muscles.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 1.3 kgCable length1.5 mDimensions of transducer head ø90 x 200 x 26 mmCoil Winding DataOuter loopø80 x160 mmInner loopø30 x 110 mmWinding height15 mmNumber of windings 10Magnetic and Electrical PropertiesMax initial dB/dt31 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 1500 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E064-18 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>RT-120-II Racetrack Coil with power control• The coil is elliptic in shape and isespecially suitable for stimulation of widerareas such as bigger muscles.• Equipped with power control and triggerbutton to support clinical operation.Mechanical PropertiesWeight of transducer head 1,5 kgCable length2,5 mDimensions of transducer head ø90 x 175 x 26 mmCoil Winding DataOuter loopø80 x 160 mmInner loopø30 x 110 mmWinding height15 mmNumber of windings 10Magnetic and Electrical PropertiesMax initial dB/dt31 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 1500 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E065-www.<strong>MagVenture</strong>.com 19


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>D-B80 Butterfly CoilMechanical PropertiesWeight of transducer head 0.9kgCable length 1.7mAngle 120°Coil winding dataDiameter2 x ø80mmWinding height12mmNumber of windings 2 x 7Magnetic and Electrical PropertiesMax initial dB/dt31 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 500 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E043-• Open butterfly design for powerfulstimulation.• The coil is suitable for deep stimulation.• The coil has a slightly bent surface toclosely follow curved shapes.• Equipped with trigger button to supportclinical operation.20 www.<strong>MagVenture</strong>.com


MC-B65-HO-2m and 8m Butterfly CoilsMagnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>• The coil handle is placed orthogonal to thecoil surface.Mechanical PropertiesWeight of transducer head 0.7kgCable length2m (B65-HO-2)8m (B65-HO-8)Dimensions of transducer head 162 x 85 x 22 mmCoil Winding DataInner diameter35mmOuter diameter75mmWinding height11mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt25 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 350 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Numbers9016E046- (2m)9016E047- (8m)www.<strong>MagVenture</strong>.com 21


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Static Cooled CoilsMCF-B65 Butterfly Coil• The Coil is designed for demandingclinical studies, requiring a high number ofstimuli without the need for externalcooling.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 1.5kgCable length2mDimensions of transducer head 174 x 94 x 53 mmCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt32 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before 2000 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E042-22 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MCF-B70 Butterfly Coil• The coil has electrical and magneticproperties similar to the MC-B70.• The Coil is designed for demandingclinical studies, requiring a high number ofstimuli without the need for externalcooling. Number of stimulations up to 3times more than MCF-B65.• The coil is produced with a slightly bentsurface to closely follow the shape of thehead. Motor threshold is achieved at 10%to 20% lower output compared to MCF-B65.• Large ergonomic handle.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 2.5kgCable length 1.3mDimensions of transducer head 180 x 116 x 45/64 mmAngle 150°Coil Winding DataInner diameter23mmOuter diameter97mmWinding height12mmNumber of windings 2 x 11Magnetic and Electrical PropertiesMax initial dB/dt28 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 5500 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Protocol: 60 trains @ 50pulses/train @ 10pps @ InterTrain Interval: 25s @Output=75% @ total number ofstimulations 3000One protocol can beperformed withoutoverheating the coil.Minimum cooling timebetween protocols:2.5 hours at 20°C or1 hour at 7°COrdering Number 9016E040-23


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MCF-75 Circular Coil• The Coil is designed for demandingclinical studies, requiring a high number ofstimuli without the need for externalcooling.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 1kgCable length 1.3mDimensions of transducer head ø88 x 41.5 mmCoil Winding DataInner diameter10mmOuter diameter65mmWinding height18mmNumber of windings 3 x 7Magnetic and Electrical PropertiesMax initial dB/dt43 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before 500 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E044-24 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MCF-125 Circular Coil• The Coil is designed for demandingclinical studies, requiring a high number ofstimuli without the need for externalcooling.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 1.5kgCable length2mDimensions of transducer head ø140.5 x 41.5 mmCoil Winding DataInner diameter35mmOuter diameter121mmWinding height6mmNumber of windings 13Magnetic and Electrical PropertiesMax initial dB/dt34 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before 2000 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E041-25


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Dynamic Cooled CoilsCool-B35 Butterfly Coil• The coil has electrical and magneticproperties similar to the MC-B35.• The coil is suitable for focused stimulationof peripheral nerves and muscles.• Compact design• The Coil is designed for demandingclinical studies, requiring a higher numberof stimuli than the MC-B35.• The Coil is cooled from an external CoolerUnit.• Large ergonomic handle.• Equipped with trigger button to supportclinical operation.• Built in timer and counter with presetoperating period (days and stimulations)Mechanical PropertiesWeight of transducer head 1.2kgCable length 1.3mDimensions of transducer head 113 x 65 x 42 mmCoil Winding DataInner diameter10mmOuter diameter46mmWinding height15mmMagnetic and Electrical PropertiesMax initial dB/dt50 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceCool-B35 used with MagPro at ambient temperature of20ºC (68ºF).• Trains: 1pps: Output=100%, Biphasic waveform:Number of stimulations before warm-up:45 (standard mode), 22 (power mode)• Trains: 1pps: Output=75%, Biphasic waveform:Number of stimulations before warm-up:90 (standard mode), 44 (power mode)• Protocol: 50 pulses/train @ 10pps @ Inter TrainInterval: 25s @ Output=75%, Biphasic waveform,standard mode:Number of trains before warm-up:10 (500 stimulations)• Protocol: 50 pulses/train @ 10pps @ Inter TrainInterval: 25s @ Output=60%, Biphasic waveform,standard mode:Number of trains before warm-up:60 (3000 stimulations)Ordering Number 9016E068-26


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cool-B65 Butterfly Coil• The coil has electrical and magneticproperties identical to the MCF-B65.• The Coil is designed for demandingclinical studies, requiring a very highnumber of stimuli.• The Coil is optimized for use withequipment enabling High Repetition Ratesand long pulse trains.• The Coil is cooled from an external CoolerUnit.• Equipped with trigger button to supportclinical operation.• Built in timer and counter with presetoperating period (days and stimulations)Mechanical PropertiesWeight of transducer head 1.7kgCable length 1.3mDimensions of transducer head 174 x 94 x 41 mmCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt36 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before >20.000 pulseswarm-up at ambient temperature20°C:Mean output 100% of maximumat 2pps.Number of stimulations, beforewarm-up at ambient temperature20°C with protocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval: 25s@ Output=75%.>10.000 pulsesOrdering Number 9016E049-www.<strong>MagVenture</strong>.com 27


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cool-B70 Butterfly CoilMechanical PropertiesWeight of transducer head 2.9kgCable length 1.3mDimensions of transducer head 180 x 116 x 45/64 mmAngle 150°Coil Winding DataInner diameter23mmOuter diameter97mmWinding height12mmNumber of windings 2 x 11Magnetic and Electrical PropertiesMax initial dB/dt28 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before >20.000 pulseswarm-up at ambient temperature20°C:Mean output 100% of maximumat 2pps.Number of stimulations, beforewarm-up at ambient temperature20°C with protocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval: 25s@ Output=100%.>10.000 pulsesOrdering Number 9016E052-• The coil has electrical and magneticproperties similar to the MCF-B70.• The Coil is designed for demandingclinical studies, requiring a very highnumber of stimuli.• The coil is produced with a slightly bentsurface to closely follow the shape of thehead.• The Coil is optimized for use withequipment enabling High Repetition Ratesand long pulse trains.• The Coil is cooled from an external CoolerUnit.• Large ergonomic handle.• Equipped with trigger button to supportclinical operation.• Built in timer and counter with presetoperating period (days and stimulations)28 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cool D-B80 Butterfly CoilMechanical PropertiesWeight of transducer head 1.8kgCable length 1.3mDimensions of transducer head 2 x ø110mmThickness 30mm°Angle 120°Coil Winding DataInner diameter67mmOuter diameter95mmWinding height12mmNumber of windings 2x (3+4)Magnetic and Electrical PropertiesMax initial dB/dt31 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before >20.000 pulseswarm-up at ambient temperature20°C:Mean output 100% of maximumat 2pps.Number of stimulations, beforewarm-up at ambient temperature20°C with protocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval: 25s@ Output=75%.>10.000 pulsesOrdering Number 9016E053-• The coil has electrical and magneticproperties similar to the D-B80.• The coil is suitable for deep stimulation.• The coil is produced with a slightly bentsurface to closely follow curved shapes.• The Coil is designed for demandingclinical studies, requiring a very highnumber of stimuli.• The Coil is cooled from an external CoolerUnit.• Large ergonomic handle.• Equipped with trigger button to supportclinical operation.• Built in timer and counter with presetoperating period (days and stimulations)www.<strong>MagVenture</strong>.com 29


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cool-125 Circular CoilMechanical PropertiesWeight of transducer head 2.5kgCable length 1,3mDimensions of transducer head ø140 x 45 mmCoil Winding DataInner diameter15mmOuter diameter121mmWinding height12mmNumber of windings 15Magnetic and Electrical PropertiesMax initial dB/dt34 kT/s near the coilsurfaceActive pulse width280μs (Biphasic)PerformanceNumber of stimulations, before >20.000 pulseswarm-up at ambient temperature20°C:Mean output 100% of maximumat 2pps.Number of stimulations, beforewarm-up at ambient temperature20°C with protocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval: 25s@ Output=100%.>10.000 pulsesOrdering Number 9016E051-• The coil has electrical and magneticproperties similar to the MCF-125.• The Coil is designed for demandingclinical studies, requiring a very highnumber of stimuli.• The Coil is optimized for use withequipment enabling High Repetition Ratesand long pulse trains.• The Coil is cooled from an external CoolerUnit.• Large ergonomic handle.• Equipped with trigger button to supportclinical operation.• Built in timer and counter with presetoperating period (days and stimulations)30 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Coil Cooler UnitMechanical PropertiesWeight of unit10kgHeight x width x depth20 x 30 x 30 cmCapacity of cooling media 1.8 literMains power cable length 3mElectrical PropertiesAvailable Main Voltage100-240V, 50-60HzPower consumptionsMaximum 40VAOrdering Number 9016B015-• Used as external cooling system for Coolcoils.• Equipped with special liquid coolingmedia.www.<strong>MagVenture</strong>.com 31


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MRi Coil SystemMRi-B90 II Butterfly Coil• The coil is suitable for focused stimulation• Designed for use in MRI scanners up to 4Tesla with biphasic Waveform Standardmode.• Coil windings are symmetrically placedinside the housing so the magnetic field onboth sides is equalMechanical PropertiesWeight of transducer head 1.1 kgDimensions of transducer head 172 x 142 x 34 mmCable length6 mCoil Winding DataInner diameter2 x ø35/ø52Outer diameter2 x ø75/ø92Distance between centers 79 mmWinding height18 mmNumber of windings2x (2x5)Magnetic and Electrical PropertiesMax initial dB/dt24 kT/sActive pulse width280μs (Biphasic)PerformanceNumber of stimulations before 300 pulseswarm-up with coil starttemperature 20°C:Mean output 100% of maximumat 1pps.Ordering Numbers9016E066- Coil MRi-B90 II9016C072- Remote Control9016C074- Emergency stop9016C075- Power Line FilterCoil MRi-B90 IIEmergency StopRemote ControlPower Line Filter32 www.<strong>MagVenture</strong>.com


Research CoilsMagnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MC-P-B70 Placebo Butterfly Coil• The coil's magnetic shield provides a fieldreduction of approximately 80%.• The Placebo Coil has a mechanical outlineand sound level identical to MC-B70.• The coil is produced with a slightly bentsurface to closely follow the shape of thehead.• Number of stimulations before warm-up isidentical to MC-B70• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 1.8kgCable length 1.3mDimensions of transducer head 169 x 112 x 36/53 mmAngle 150°Coil Winding DataInner diameter20mmOuter diameter100mmWinding height6mmNumber of windings 2 x 10PerformanceNumber of stimulations before 400 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E059-www.<strong>MagVenture</strong>.com 33


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MCF-P-B65 Placebo Butterfly Coil• The coil's magnetic shield provides a fieldreduction of approximately 80%.• The Placebo Coil has a mechanical outlineand sound level identical to MCF-B65.• With a reduction of stimulus intensity with20-25% the coil can perform the samenumber of stimulations as the normalMCF-B65.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 2.9kgCable length2mDimensions of transducer head 174 x 94 x 53 mmCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)PerformanceNumber of stimulations before 1600 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E060-34 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cool-B65 A/P Butterfly Coil• The Cool-B65-A/P Coil is designed foradvanced clinical studies where doubleblinded research experiments are required.• The Cool-B65-A/P functions both as anactive (A) coil and as a placebo (P) coil.• The Cool-B65-A/P has a symmetricalmechanical design and no labeling on thecoil indicates the active or placebo side.Consequently it is not possible for theoperator to see or hear which side is used.• The coil has electrical and magneticproperties identical to the MCF-B65 andCool-B65.• Built-in orientation switch to determinewhich side the operator shall directtowards the patient.• For use only with <strong>MagVenture</strong> rTMSResearch software (MagLink).• Adjustable output for current stimulationsurface electrodes enables skin stimulationto occur synchronously with the magneticstimulation pulse• Built in timer and counter with presetoperating period (days and stimulations)• Includes Stimulator Electrode Cable andone pack of Surface Electrodes (12pcs.)Mechanical PropertiesWeight of transducer head 3kgCable length 1.3mDimensions of transducer 174 x 94 x 80 mmheadCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt Max initial dB/dt: 36 kT/s near thecoil surface on the active side,same as Cool-B65 Coil.The magnetic field near the coilsurface on the placebo side isreduced to 20.000 pulseswarm-up at ambienttemperature 20°C:Mean output 100% ofmaximum at 2pps.Number of stimulations, beforewarm-up at ambienttemperature 20°C withprotocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval:25s @ Output=75%.>10.000 pulsesOrdering Number 9016E050-www.<strong>MagVenture</strong>.com 35


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Stimulator Electrode Cable and Electrodes for Cool-B65A/P CoilSurface Electrodes (pack of 12pcs.)Electrode size28 x 20 mmSensor materialSilver / silver chlorideGel systemSolid gelSensor area 490 mm 2Cable length50 cmConnector1.5mm female TPOrdering Number 9016S020-• Pack of Pre-gelled Surface electrodes(12pcs.) with 1.5mm touch-proofconnector.Shielded Electrode cableCable lengthConnector for electrodes2 m1.5mm male TP (2 pcs.)Ordering Number 9016C080-• Stimulator Electrode cable for Cool-B65A/P Coil with 1.5mm touch-proofconnectors.36


Basic Stimulator <strong>Accessories</strong>Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Super Flex Arm for Magnetic Coil Positioning• For easy and flexible positioning of themagnetic coils.• The arm has three joints. Two ball jointswhich can rotate in multiple directions andone central joint which can rotate in onedirection.• All three joints can be locked and unlockedby the grip on the central joint.• Designed for use with all types of coils.• Mounted on the side of the trolley forMagPro.Mechanical Properties (long version)CoilsAll coilsLength of armVertical rod: 60cmFlexible rods: 2 x 40 cmWeight of arm6.5 kgOrdering Number 9016B017-Mechanical Properties (short version)CoilsAll coilsLength of armVertical rod: 60cmFlexible rods: 2 x 25 cmWeight of arm6 kgOrdering Number 9016B018-www.<strong>MagVenture</strong>.com 37


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MagProbeProbe for magnetic field evaluationMagProbe is designed to provide informationabout the magnetic field from stimulatingcoils. The probe is useful as a simple tool forestimating the suitability of a specific coil,intended for a specific application. Inaddition, the probe enables the user to predictthe ability to stimulate at different locations intissue, when using different coil positions.MagProbe provides a quantitative measure ofthe field gradient and the peak magnetic fieldamplitude. The MagProbe output isproportional to the magnetic field change withtime (dB/dt). The change in the magnetic fieldwith time induces a proportional voltage intissue. This voltage generates a current, theamplitude of which is depending on theconductivity of the tissue and bone structure.This is the current that can stimulate the nerveand muscle fibers.MagProbe (BNC); with a standard BNCconnector for easy usage with an oscilloscope.2 different types of MagProbes are available.MagProbe (DIN); with a standard DINconnector for easy usage with EMG/EPequipment.Technical Data for MagProbe (DIN)Connector5p DIN plugCable length3 mLoop wireø2.8mm CU.Loop inside diameter 20mm.Output voltage 1 mV per 1 kT/s.Accuracy ±10%Approx. peakCorrection factors20kHz 1.210kHz 1.45kHz 1.8Ordering Number 9016E031-Technical Data for MagProbe (BNC)ConnectorBNC plugCable length3 mLoop wireø2.8mm CU.Loop inside diameter 20mm.Output voltage 1 V per 2.6 kT/s.Accuracy ±10%Ordering Number 9016E033-38 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cable for ExternalTriggering with D-subCoil Converter (ExternalPower Control)Technical DataConnectorsCable lengthOrdering Number 9016E455-9p D-sub plug (MagPro)9p D-sub plug (Keypoint)3 m• Interface unit to be used with MagProCompact only.• The unit is mounted on the front ofMagPro Compact between the stimulatorand the coil• The external power control is for coilswithout controls in the coil handle. Instead,the control is carried out from the externalpower control.Cable for ExternalTriggering with BNCTechnical DataCoilsAll coils exceptC-100, C-B60, MMC-140-II andRT-120-IIWeightNote:F- and Cool-coils types are notrecommended for MagProCompact140gOrdering Number 9016E045-Technical DataConnectorsCable length9p D-sub plug (MagPro)2 x BNC plug3 mOrdering Number 9016E456-www.<strong>MagVenture</strong>.com 39


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Trolley for MagProTrolley for MagProCompactMechanical PropertiesWeight13.5kgHeight x width x depth 80 x 61 x 55cmOrdering Number 9016B010-Mechanical PropertiesWeightHeight x width x depth11.7kg80 x 56 x 55cmExtra ShelfWeight2.9kgHeight x width x depth 3 x 55 x 31cmOrdering Number 9031B311-Ordering Number 9016B011-Extra ShelfWeight1.4kgHeight x width x depth 3 x 50 x 45cmOrdering Number 9031B304-40 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>110V Power SupplyOption for MagProCompact110V/230V Power SupplyOption for MagProMechanical PropertiesWeight of transformer7kgCable length primary3mCable length secondary 1.3mHeight x width x depth11 x 18 x 18 cmEncapsulationOverall min 2 mm PSNon flammableImpact resistantMechanical PropertiesWeight of transformer15kgCable length primary 1.5mCable length secondary 1.3mHeight x width x depth20 x 30 x 30 cmEncapsulationOverall min 2 mm PSNon flammableImpact resistantElectrical PropertiesAvailable Main VoltageMax Energy Output100V, 115V, 127V750VAElectrical PropertiesAvailable Main VoltageMax Energy Output100V, 110V, 120V2300VAOrdering Number 9016D002-Ordering Number 9016D001-www.<strong>MagVenture</strong>.com 41


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Isolation Transformer for MagPro System solutionsMechanical PropertiesWeight of unitHeight x width x depthCable length primaryCable length for MagProEncapsulationElectrical PropertiesMains Voltage Inlet15kg12 x 30 x 23 cm3m2mOverall min 2 mm PC Nonflammable Impact resistant9016D003-: 120V~, 50/60Hz9016D004-: 230V~, 50/60Hz9016D005-: 100V~, 50/60Hz• For supporting MagPro System solutionswith MagPro and other <strong>MagVenture</strong>devices, an Isolation Transformer isrequired.• The Isolation Transformer is available indifferent models for supporting local mainspower; 100V~, 120V~ and 230V~.• Outlet for MagPro Stimulator and four230V auxiliary outlets for other devicessuch as Treatment Chair, Vacuum PumpUnit and Coil Cooler Unit• Complies with the leakage currentrequirements according to IEC 60601-1-1Outlet for MagProAuxiliary outletsOrdering NumbersFixed cable , 230V~, 50/60Hz4 pcs. IEC, 230V~, 50/60Hz,Total max 100VA9016D003- (120V~/230V~)9016D004- (230V~/230V~)9016D005- (100V~/230V~)42 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>MagPro Remote ControlMechanical PropertiesDimensions (WxDxH) 117 x 79 x 19 mmWeight0,4 kgCable length 8 m *Connector6 pole Lemo typeEncapsulation material ABS plastic with soft side gripfor hand-held comfortHousing protection IP20Ordering Number 9016C072-* Other lengths can be specified.• The MagPro Remote Control provides theuser with the possibility to operate theMagPro from a distance.• With the MagPro Remote Control it ispossible to make single stimuli and to setthe output power from a distance.• The LED indicates whether the Stimulatoris enabled or disabled.• Can be used with all available types ofMagPro.www.<strong>MagVenture</strong>.com 43


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Research <strong>Accessories</strong>Treatment Chair with neck rest• Wide and optimal comfort design.• Possible to adjust height and tilting of seat,footrest and backrest for best possiblecomfort.• Specially designed neck rest for use withvacuum pillow to ensure stable positioningof the patient’s head during treatment.Electrical PropertiesMains inletMotors230V AC4 motors for height, tilting of seat,footrest and backrest adjustmentMechanical PropertiesColorWhiteWidth63 cm without armrest, 80 cm witharmrestHeight63-87 cmLength190-210 cmWeight85 kg / 187 lbsPatient max. weight 130 kg / 286 lbsOrdering Number 9016B008-44 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Vacuum Pump and Vacuum Pillow• Vacuum Pump unit for vacuum pillows forstable support of the patient’s head duringmagnetic stimulation.• Easy control by foot switch.• When air is evacuated by use of theVacuum Pump unit, the pillow becomesstable in the chosen form and stiffness.When the air valve is released, allowing airinto the pillow, the Vacuum Pillow regainsits flexibility and is ready to be shapedagain.• The Vacuum Pillow consists of an airtightshell containing granules of polystyrene.• Delivered with washable pillow cases.Vacuum Pump UnitMechanical PropertiesWeight of unit4.5kgHeight x width x depth 12 x 30 x 23cmEncapsulationOverall minimum 2 mmPC Non flammableImpact resistantVacuum performance


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Textile Caps for repositioning• With the caps it is easy to mark theposition for a magnetic coil. This facilitatescorrect repositioning of the coil at futuretreatment sessions.• Head caps in textile material.• Available in different sizes; S, M, L andXL.• For right repositioning of the cap on thepatient head, the distance from the edge ofcap to the nasion point can be used.• Patient ID and distance to the edge of thecap can be written on the cap. One cap perpatient.CapsMaterialTextile with elastic band in the backof the neckSizes Small: 54-56 cmMedium: 56-58 cmLarge: 58-60 cmExtra large: 60-62 cmOrdering Small: 9016B020- (10 pcs.)Numbers Medium: 9016B021- (10 pcs.)Large: 9016B022- (10 pcs.)Extra large: 9016B023- (10 pcs.)46 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Marking <strong>Accessories</strong> for Depression studiesDLPFCAPB motorcortex6 cm“6-cm rule”• When performing depression studies thetreatment spot is normally based on thestandard 6cm rule anterior to APB motorcortex. Other standards e.g. 5cm onrequest.• With marking plate for C-B60 coilmounted, the DLPFC spot is easy locatedduring the motor threshold determination.When APB motor cortex is located acurved line is drawn with a pen along themarking plate.• The curved line from the marking has theshape of the Cool-B65 and Cool-B65 A/Pcoil and it will be easy to positioning thetreatment coil on the scalp over DLPFC.• With the marking plate mounted on the C-B60 coil the magnetic field is equal to theCool-B65 and the Cool-B65 A/P coil’sactive side.Marking accessories for Depression studiesMarking plate forC-B60 CoilMeasurement pinOrdering Number 9016B019-1.5mm plastic.Based on 6 cm rule standardanterior to APB motor cortexScale in millimeters andcentimeterswww.<strong>MagVenture</strong>.com 47


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Sham Noise GeneratorTechnical DataOutput sham noise amplitudePulse width of the sham noiseMax 100dB25-200mSMechanical PropertiesDimensions (WxDxH) 86 x 35 x 170 mmWeight0.4 kgCable length 2.5mConnectorsStereo MP3 input max 1V-rms3.5 mm stereo jackTwo Stereo audio outputs 3.5mm stereo jackEncapsulation material ABS plasticHousing protection IP20 TightOrdering NumbersSham Noise Generator 9016C077-Additional Headset 9016C078-• In order to hide the click noise when amagnetic stimulation pulse is fired, whitenoise is send into the ears of the patient.• This sham noise pulse will hide the clicknoise from the coil for the patient; even at100% stimulus intensity.• For double blinded research experimentsthe MagPro operator should also receivethe sham noise.• It is possible to connect an iPod or similarto the Sham Noise Generator to make thepatients feel comfortable with music duringthe treatment.• Two headsets are included, each with 2mextension cables48 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong><strong>Accessories</strong> for Trolley• When performing research or depressionstudies with rTMS often more than one coilis used during the process.• This accessories kit includes:o holder for an extra standard coil, (e.g.C-B60 for motor threshold determination)o holder for coil connector of rTMS coilduring motor threshold determinationo holder for USB connectors from the rearpanel of MagPro• With this kit all components are easilyplaced on the trolley<strong>Accessories</strong> for TrolleyHolder for standard coilsHolder for rTMS coilconnectorHolder for USB connectorsMounted on the side oftrolleyMounted on the side oftrolleyMounted on the side oftrolleyOrdering Number 9016B028-www.<strong>MagVenture</strong>.com 49


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>EMG <strong>Accessories</strong>MEP Monitor, 1 channel EMG amplifier• 1 channel EMG amplifier to be mountedon the back of the MagPro system.• Measurement of Motor Evoked Potentials(MEP).• Specially designed for determination anddocumentation of Motor Threshold.• Includes MEP Electrode Cable and onepack of Surface Electrodes (12pcs.)Technical DataDimensionsWeightNumber of InputsSound(HxWxD:) 184 x 94 x 40mm0.7kg1 input protected against electrostaticdischarge. Balanced inputs.1 pc. 5-pole DIN 240° connector forelectrode cableOutput for external loudspeaker,3.5mm jack.Patient Safety EMG channel galvanically isolated1.5 kV RMSInput Impedance 200 MΩ // 100 pF (balanced), >1000MΩ // 50 pF (common mode)Noise LevelCommon ModeRejection RatioIsolation ModeRejection RatioSensitivity FactorsTime ScalesTrigger ModeLower FrequencyLimits (-3dB): DSPUpper FrequencyLimits (-3dB): DSPAnti-AliasingSamplingTypical 0.6 μVrms at bandwidth2 Hz to 20 kHz and shorted inputFrom surface electrode, throughcable and amplifier: >55 dB.Direct: >100 dBFrom input to power ground:>160 dB100, 200, 500 μV/Div,1, 2, 5, 10 mV/Div1, 2, 5, 8, 10 ms/DivLevel, Autotrig on stim1, 2, 5, 10, 20, 50, 100 Hz,1, 2, 5, 10, 20 kHz,20 kHz (-3 dB), 1 st order100 ks/s, 16 bitOrdering Number 9016C070-50 www.<strong>MagVenture</strong>.com


Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Electrode cable and Electrodes for MEP MonitorSurface Electrodes (pack of 12pcs.)Electrode size28 x 20 mmSensor materialSilver / silver chlorideGel systemSolid gelSensor area 490 mm 2Cable length50 cmConnector1.5mm female TPOrdering Number 9016S020-• Pack of Pre-gelled Surface electrodes(12pcs.) with 1.5mm touch-proofconnector. Used for MEP recordings asActive, Reference and Ground electrode.Shielded Electrode cableCable length3 mConnector for MEP Monitor 5-pole DIN 240°Connector for electrodes 1.5mm male TP (3 pcs.)Ordering Number 9016C081-• Shielded Electrode cable for MEP Monitorwith 1.5mm touch-proof connectors forActive, Reference and Ground electrodes.www.<strong>MagVenture</strong>.com 51


MagPro and accessories are manufactured by:Tonica Elektronik A/SLucernemarken 15DK-3520 FarumDenmarkTelephone: +45 44 99 84 44Fax: +45 44 99 15 44www.tonica.dkDistributed by:<strong>MagVenture</strong> A/SLucernemarken 15DK-3520 FarumDenmarkTelephone: +45 44 99 84 44Fax: +45 44 39 04 49www.magventure.comIssued in Denmark, March 2011. P/N: 501-0623, rev. 5.7