13.07.2015 Views

Certification Service Sira Certificatlon Service

Certification Service Sira Certificatlon Service

Certification Service Sira Certificatlon Service

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

sira•<strong>Certification</strong> <strong>Service</strong>SCHEDULETYPE EXAMINATION CERTIFICATE NUMBER:5ira 03ATEX4288UThe marking is either moulded loto the body cf the terminal cr "tampo" printed onto it.All the terminals may be used in associatlon with Type QB 2, QB 3 cr QB4 (two way, three way or fourway respectively) cross-connectors and/or partitions, in which case, the voltage and current ratings areunchanged. In addition, all the terminals may be used in assoclatlon with AP end plates. The terminalassembly is to be damped in pface, at both ends, uslng either a Weidmuller, Type EK earth terminal, orossocioted Type EW (15, 15/2 o. 35), EWK(1 o. 2), WEW (35/1 Of 35/2) end bracket respeclively.14 DESCRIPTIVE DOCUMENTS14.1Drawing Rev. Sheet Date Title4 36258 0 1 of 1 11 Jun 03 SAK R (TS32) Terminal- Polyamide PA66436418 0 1 cf 1 31 Mar 04 SAK R 35 Terminal- Polyamide PA664 36406 0 1cf 1 31 Mar 04 SAK R 15 Terminal- Polyamide PA664 36233 0 1 cf 1 14 May 03 Q8 2-4 eross-connection Comb2 04546 12 1cf 1 02 Nov 05 SAK R Marking Details4 36260 0 10fl 12 Jun 03 AP End Plate14.2 Report numbers R53A8244A & R51L13177AI15 SPECIAL CONDmDNS FOR SAFE USE15.1 The end terminal shall be covered with the associated Type AP end plate and the terminal assemblyc1amped in place at both ends, using either a Weidmutler, Type EK earth terminal or associated endbrackets types EW (15,15/2 o. 35), EWK(1 o. 2) 000 WEW (35/1 Of 35/2) respeclively.15.2 Where wire sizes that are smaller than 0.5 mm 2 are used, a climped lug or femJle with a minimum size of0.5 mm 2 shall be fitted to the wire.15.3 Except where shown in a certJficate as belng internal wiring of apparatus, not more than one sIngle ormultiple strand lead shalt be connected into either side of any terminal, unless multiple conductors havebeen joined in a suitable manner, e.g. two conductors into a single insulated crimped boot lace ferrule.15.4 Any wlres that are connected to the terminals shatl be insulated for the appropriate voltage and thisinsulation shall extend to within 1mm of the metal of the telTTllnal throat.15.5 All telTTlinal screws, used or unused, shall be tightened down.15.6 The telTTlinais shal1 be installed on the relevant mounting rail:TypeRaUStandardSÄKR EN 60715:2001SÄ" R 15 EN 60715:2001SAKR 35 EN 60715:2001Weldmuller rail referenceTS32TS15TS3515.7 The minimum aeepage and dearance distances between the installed terminals and adjacent exposedfaces of equipment, endosure walls and covers shall be 5 mm and 4 mm respectlvely.Date 1 October 2004latest issue 25 November 2005This certificate and its sd1edu1es may only be reproduced in it5 entirety Md without any changeForm9219Issue3Page 3 cf 4<strong>Sira</strong> <strong>Certificatlon</strong> <strong>Service</strong>Rak.e Lane. Eccleslon, Chester. CH4 9JN. EnglandTel: +44 (0)1244 670900 Fax; +44 (0)1244 681330Email; exhazardOsira.co.uk.<strong>Sira</strong> CertfficafiQn <strong>Service</strong> is a service 01 Sire Tesl &. CertificatiOn Lid

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!