Technical DataTypeType designationApprovals/ standardsApplication<strong>PROTOLON</strong> (<strong>SMK</strong>) <strong>LWL</strong>(N)TSKCGEWOEUDIN VDE 0250, Part 813, MSHA P1894; GOST RFlexible H.V. flexible reeling cable, also suitable for festoon systems, for high toextreme mechanical stresses, e.g. high travel speeds, dynamic tensile loads,multiple changes of direction into different planes, churning on running overrollers and torsional stresses. Mainly for mobile equipment, e.g. fastmovingcontainer cranes, cranes, large mobile equipment and excavators. Also forapplication to which DIN VDE 0168 and 0118 apply: Opencast andunderground mining.ElectricalparametersOpticalparametersRated voltage (Uo/U) 1,8/3 3,6/6 6/10 8,7/15 12/20 14/25 18/30Maximum permissibleoperating voltage in ACsystems (Uo/U)Maximum permissibleoperating voltage in DCsystems (Uo/U)2,1/3,6 4,2/7,2 6,9/12 10,4/18 13,9/24 17,3/30 20,8/362,7/5,4 5,4/10,8 9/18 13,5/27 18/36 22,5/45 27/54AC test voltage 6,0 11,0 17,0 24,0 29,0 36,0 43,0according to DIN VDE 0250, Part 813Currentcarrying capacity According to DIN VDE 0298, Part 4Higher values are permissible in specific cases.Please consult the manufacturer.Data transmissionEMCTransmission data of thefibreopticsMax. attenuation atwavelength 850 nmMax. attenuation atwavelength 1300 nmMax. attenuation atwavelength 1550 nmSpecial design with fibreoptics for trouble free data transmission at high datarates.This design exhibits an extremely low interference level as a result of use asymmetrical threecore design with very narrow manufacturing rates.Gradedindex fibre Gradedindex fibre Monomode fibre50/125 62.5/125 E9/1252.8 dB/km 3.3 dB/km 0.8 dB/km 0.4 dB/km 0.9 dB/km 0,3 dB/kmBandwidth at 850 nm > 400 MHz > 400 MHz Bandwidth at 1300 nm > 1200 MHz > 600 MHz Numerical aperture 0,200+/0,200 0,275+/0,02 0.14+/0.02Chromatic dispersionat 1300 nmChromatic dispersionat 1550 nm
Technical DataThermalparametersMechanicalparametersAmbient temperature Fully flexible operation 35°C to +80°C Fixed installation 50°C to +80°CMaximum permissibleoperating temperature of theconductorShortcircuit temperature ofthe conductordynamical tensile load atacceleration processesmax. permanent tensile loadTorsional stresses90°C250°Cup to 30 N/mm² (acc. to: DIN VDE 0298 part 3: 15 N/mm²)up to 20 N/mm²+/25°/mMinimum bending radii According to DIN VDE 0298, Part 3Minimum distance with Stypedirectional changesTravel speed20xD (cable diameter) Gantry (reeling operation) No restriction. For speeds beyond 240 m/min it is recommended to consult thecable manufacturerAdditional testsReversed bending test, torsional stress testChemicalparametersNote oninstallationResistance to oil DIN VDE 0473, Part 81121 Para. 10Weather resistanceWater compatibility According to HD 2216Unrestricted use outdoors and indoors, resistant to ozone, UV and moisturePreparation of fibreoptics requires special skills and use of elaborate tools. It istherefore recommended that performance of this work be entrusted to ourcustomer service. (Assembly at works)Please give the connection dimensions.