<strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong>Fixed Combustible Gas Monitor, 4-20 mA transmitterThe <strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong> is apermanently mounted (fixed)catalytic bead combustible gastransmitter that operates from 9to 36 VDC power source andprovides a 4-20mA analog outputin the range of 0-100%<strong>LEL</strong>combustible gas. Themicroprocessor based circuit ishoused in an explosion-proofenclosure, the <strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong>is equipped with a local digitaldisplay of the gas concentrationand function keys for performingcalibration. The <strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong>is operated with a standard4-20mA controller or as astand-alone sensor module.Key Features• Highly poison-resistantcatalytic bead combustiblegas <strong>LEL</strong> sensor• 4-20mA analog output of0-100%<strong>LEL</strong> combustible gasincluding methane,acetylene, propane or othercombustible gases• Explosion-proof enclosurefor hazardous environmentapplication• Magnetic key interfaceeliminates need to openexplosion-proof housingwhen making calibration orother minor adjustments• Operation at 9 to 36 VDC• Dry contact output (


SpecificationsDefault Sensor SettingsGas Range ResolutionResponseTime (T 90 )Combustible Gas 0-100%<strong>LEL</strong> 1%<strong>LEL</strong> 15sDetector SpecificationsSizeWeightDetectorRangeResolutionAccuracyHazardousLocationClassificationsPowerSignal OutputSamplingDisplayResponse Time(t 90 )User InterfaceCalibration12.7cmx12.7cmx11.5cm(5.0”Lx5.0”Wx4.5”H)2.5kg (5.5 lbs)7R-sized protected catalytic beadcombustible gas sensor0-100% <strong>LEL</strong>1% <strong>LEL</strong>+/- 2% <strong>LEL</strong> or +/-10% of readingUL: Class I, Division 1, Group B,C,DTemperature Code T69-36 VDC max 160mA at 24V4-20mA with 12V compliance at 24VpowerInternal diffusion7-segment, 4-digit LCD with 4color-coded fault LEDs15 seconds to 90% of reading to50%<strong>LEL</strong> methaneMagnetically accessed keys forcalibrationTwo point field calibrationTemperature -20 to +55° C (-4 to +131° F)Humidity0-95% relatively humidity(non-condensing)Pressure700-1,300hPaDry Contact Max 30V, 2AMounting2 holes 133mm (5.25”) from center tocenterWiring3 or 4 wires*Ongoing projects to enhance our products means that thesespecifications are subject to changes<strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong> Ordering Information<strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong> Basic Kit FGM-1100• <strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong> detector with 7R-size <strong>LEL</strong>sensor• Installation, operation and maintenancemanual• Magnetic key• Calibration adapterInstallation Drawing<strong><strong>RAE</strong>Guard</strong> <strong>LEL</strong><strong>RAE</strong> <strong>Systems</strong> Inc.<strong>RAE</strong> <strong>Systems</strong> Europe3775 North First Street, San Jose, CA • 95134 • USA Orestads Boulevard 69, 2300 Copenhagen S • DenmarkTel: 408.952.8200 • Fax: 408.952.8480 Tel: +45.8652.5155Email: raesales@raesystems.com<strong>RAE</strong> <strong>Systems</strong> (Hong Kong) Ltd.http://www.raesystems.comRoom 8, 6/F, Hong Leong Plaza, 33 Lok Yip Road, Fanling, N.T. • Hong KongTel: 852.2669.0828

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!