FUSE SELECTION PROCEDURE CHART FORCOPELAMETIC COMPRESSORS1. Determine Rated Load Amps (RLA) from nameplateor <strong>Section</strong> F.2. Determine Locked Rotor Amps(LRA) from nameplateor <strong>Section</strong> F.3. Divide LRA/RLA for Inrush Ratio.4. If fuse ambient temperature is greater than 120°F,multiply Inrush Ratio by 1.08.5. For Single Phase compressors, multiply RLA by:1.5 if Inrush Ratio is 5 or less, or1.6 if Inrush Ratio is more than 5.6. For Three Phase compressors, multiply RLA by:1.4 if Inrush Ratio is 4 or less, or1.5 if Inrush Ratio is more than 4.7. Use the next higher Time Delay fuse rating above theadjusted RLA value calculated in step 5 or step 6.NOTE: IN NO CASE MAY FUSE RATING EXCEED225% OF COMPRESSOR RLA!C3<strong>Section</strong> C.indd 32/5/2008 8:01:07 AM