Checking and replacing the magnesium anode (if required)Check the magnesium anode. If it is discovered that the anode has degraded to 10to 15 mm Ø, we recommend replacing the magnesium anode.Returning the primary store into useCommissioning, inspection, maintenanceFurther details regarding the individual steps (cont.)1. Reconnect the primary store to thepipework.2. Insert new gasket A underneathflange lid B.3. Fit flange lid B and tighten eightscrews D with up to 25 Nm.4. Push earth cable C onto tab.5. Fit cover E.6. Fill the primary store with drinkingwater.5457 552 GBService43