13.07.2015 Views

Mineral-insulated thermocouples to DIN 43 710 and EN 60 584 - Jumo

Mineral-insulated thermocouples to DIN 43 710 and EN 60 584 - Jumo

Mineral-insulated thermocouples to DIN 43 710 and EN 60 584 - Jumo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JUMO GmbH & Co. KGDelivery address: Mackenrodtstraße 14,3<strong>60</strong>39 Fulda, GermanyPostal address: 3<strong>60</strong>35 Fulda, GermanyPhone: +49 661 <strong>60</strong>03-0Fax: +49 661 <strong>60</strong>03-<strong>60</strong>7E-mail:mail@jumo.netInternet: www.jumo.netJUMO Instrument Co. Ltd.JUMO HouseTemple Bank, RiverwayHarlow - Essex CM20 2DY, UKPhone: +44 1279 63 55 33Fax: +44 1279 63 52 62E-mail: sales@jumo.co.ukInternet: www.jumo.co.ukJUMO Process Control, Inc.8 Technology BoulevardCanas<strong>to</strong>ta, NY 13032, USAPhone: 315-697-JUMO1-800-554-JUMOFax: 315-697-5867E-mail: info@jumo.usInternet: www.jumo.usData Sheet 90.1210 (90.1221) Page 5/7Order details: <strong>Mineral</strong>-<strong>insulated</strong> <strong>thermocouples</strong> <strong>to</strong> <strong>DIN</strong> <strong>43</strong> <strong>710</strong> <strong>and</strong> <strong>EN</strong> <strong>60</strong> <strong>584</strong>(1) Basic version901250/32<strong>Mineral</strong>-<strong>insulated</strong> thermocouplewith siliconized compensating cable901250/33<strong>Mineral</strong>-<strong>insulated</strong> thermocouple withPTFE- <strong>insulated</strong> compensating cable901250/34<strong>Mineral</strong>-<strong>insulated</strong> thermocouple<strong>and</strong> compensating cable withmetal-braiding <strong>and</strong> glass silk insulation(2) Measuring insert / operating temperature in °Cx x x 1040 1 x Fe-Con J, operating temperature -200 <strong>to</strong> +800°C, sheath, Mat. Ref. 1.4541x x x 1042 1 x Fe-Con L, operating temperature -200 <strong>to</strong> +800°C, sheath, Mat. Ref. 1.4541x x x 10<strong>43</strong> 1 x NiCr-Ni K, operating temperature -200 <strong>to</strong> +1200°C, sheath, Mat. Ref. 2.4816x x 2042 2 x Fe-Con L, operating temperature -200 <strong>to</strong> +800°C, sheath, Mat. Ref. 1.4541x x 20<strong>43</strong> 2 x NiCr-Ni K, operating temperature -200 <strong>to</strong> +1200°C, sheath, Mat. Ref. 2.4816(3) Protection tube diameter D in mmx x x 0.5 0.5mm, only with Type 1 x NiCr-Ni Kx x x 1 1mmx x x 1.5 1.5mmx x x 2 2mmx x x 3 3mmx x x 4.5 4.5mmx x x 6 6mm(4) Fitting length EL in mm (50 ≤ EL ≤ 50000)x x x 100 100mmx x x 200 200mmx x x 300 300mmx x x 400 400mmx x x 500 500mmx x x ... please specify in plain text (50mm steps)(5) Compensating cable endx x x 03 bare cable endsx x x 11 ferrules <strong>to</strong> <strong>DIN</strong> 46 228 Part 4 (st<strong>and</strong>ard)x x x 13 receptacle 6.3 <strong>to</strong> <strong>DIN</strong> 46 247x x x 80 multipole connec<strong>to</strong>r (please specify type in plain text)(6) Compensating cable length AL in mm (500 ≤ AL ≤ 500000)x x x 2500 2500mm (st<strong>and</strong>ard)x x x ... please specify in plain text (500mm steps)(7) Extra codesx x x 000 no extra codex x x 309 un<strong>insulated</strong> assembly (thermocouple welded <strong>to</strong> tip)x x x 317 shielded compensating cable(1) (2) (3) (4) (5) (6) (7)Order code - - - - - / ,...Order example 901250/32 - 1042 - 3 - 200 - 11 - 2500 / 000 11. List extra codes in sequence, separated by commas.2009-07-23/00073440

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!