FOCUSONcoating applicatorsFOCUSONCONSULTANTS<strong>Corrosion</strong>Management | March/April 2012RHINOCEROSQueen Elizabeth II BridgeOne <strong>of</strong> Belfast’s road bridges is about to emergefrom major refurbishment, a challengingjob completed against tight deadlines. Thecoating contractors are RHINOCEROS, aquickly growing infrastructure maintenancecompany based in London.2012 is a special year for Belfast: not only is it<strong>the</strong> Titanic Centenary year, but also <strong>the</strong> Queen’sDiamond Jubilee. A landmark common toboth is <strong>the</strong> Queen Elizabeth II Bridge. Thebridge was opened by <strong>the</strong> Queen in 1967, andspans <strong>the</strong> River Lagan just a seagull’s hop from<strong>the</strong> Harland and Wolff yard which launched<strong>the</strong> most famous ship in history. The massiveshipyard gantries are now sadly quiet, but <strong>the</strong>Queen Elizabeth II Bridge is busier than ever.The Department for Regional DevelopmentNor<strong>the</strong>rn Ireland decided late last year to giveit a proper refurbishment as part <strong>of</strong> <strong>the</strong> BelfastCity’s preparations for 2012.The contract was always going to presentspecial problems, and RHINOCEROS sentan experienced Contract Manager, BillPrendergast, to inspect <strong>the</strong> Bridge and prepare<strong>the</strong>ir plan. Time was already tight – <strong>the</strong>deadline was April 2012 and <strong>the</strong> contract wasonly awarded in December 2011. <strong>In</strong>spectionsrevealed extensive corrosion and failure <strong>of</strong>existing coatings, most visibly on <strong>the</strong> parapetsand handrails. The beams underneath wereworse: pigeons had deposited up to 7” <strong>of</strong>guano throughout <strong>the</strong> structure, and <strong>the</strong>existing chlorinated rubber coatings wereseverely damaged.Refurbishing any transport infrastructure canbe a logistical headache. The Bridge had to bekept open to road and foot traffic throughout<strong>the</strong> operation, and <strong>the</strong>re were plenty <strong>of</strong> minorinconveniences, such as a one-way systemwhich meant a City centre detour to movesupplies and plant from one end <strong>of</strong> <strong>the</strong> Bridgeto <strong>the</strong> o<strong>the</strong>r. On top <strong>of</strong> that, work was to startin February, when cold and damp could beexpected to be at <strong>the</strong>ir worst.RHINOCEROS built its early reputation ongraffiti removal and anti-graffiti coatings,but are now just as likely to be seen tacklinglarge infrastructure maintenance projectsall over <strong>the</strong> country, and beyond. Lateralthinking and problem-solving approach haswon <strong>the</strong> RHINOCEROS team friends in manymaintenance departments. Bill cut his teeth in<strong>the</strong> Southampton marine industry and worksboth as a Contracts Manager and as a Paint<strong>In</strong>spector with ICORR Level 3 accreditation.His team are all ICATS accredited, or workinghard to complete <strong>the</strong>ir ICATS training underBill’s active supervision.Concrete refurbishment was being doneconcurrently by Graham Structural Solutions<strong>of</strong> Belfast, and <strong>the</strong>y planned to control <strong>the</strong>temperature and humidity at levels whichwould allow painting by installing a WackerNeuson ground heater. This powerful US buil<strong>the</strong>ater is designed for thawing out frozenground and heating very large buildings.Calculations showed <strong>the</strong> device could heat<strong>the</strong> entire structure by 1 degree C in 24hours, so less than a week would be neededto take it from 0 degrees C to a workable 5degrees Celsius. <strong>In</strong> fact, Bill says <strong>the</strong> heatingwas so efficient that his workmen were ableto do most <strong>of</strong> <strong>the</strong>ir work at a comfortable 15degrees C.The bridge had previously been paintedwith up to 6 coats <strong>of</strong> chlorinated rubber.Consultations between RHINOCEROS,Belfast’s Road Agency and Mike Taylor <strong>of</strong> PPG/Sigma resulted in a specification for 40% blastcleaning to SA 2.5, with <strong>the</strong> remainder <strong>of</strong> <strong>the</strong>structure being sweep blasted to remove only<strong>the</strong> top chlorinated rubber.Mike Taylor says “From experience withHighways Agency bridges, over-coating<strong>the</strong>se types <strong>of</strong> systems can be fraught withdifficulty. Applying an epoxy system such asHA115, HA116, HA168, over <strong>the</strong> physicaldrying chlorinated rubber systems has led toexperiences <strong>of</strong> cracking, delamination andcrazing.Success is measured on <strong>the</strong> long term adhesion<strong>of</strong> <strong>the</strong> coatings to all <strong>the</strong> different surfaces <strong>of</strong><strong>the</strong> structure. External areas on outer beamsthat are subject to sun and temperaturerises and falls are far more difficult to coatsuccessfully because <strong>of</strong> <strong>the</strong> difference in<strong>the</strong>rmal characteristics <strong>of</strong> <strong>the</strong> chlorinatedrubber compared with <strong>the</strong> epoxy. Thechlorinated rubber will expand and contractwith temperature whereas <strong>the</strong> epoxy is morerigid and if applied over <strong>the</strong> chlorinated rubberis likely to crack.Experience from o<strong>the</strong>r Highways Agencybridges has shown that on outer beams<strong>the</strong> best option is to remove <strong>the</strong> existingchlorinated rubber system by abrasive blastcleaning and apply a new epoxy system.The under deck areas, where <strong>the</strong> existingchlorinated rubber system is more shelteredfrom <strong>the</strong> temperature fluctuations, canpossibly be treated with an epoxy system. Ithas been found that spot priming with HAItem 115 and <strong>the</strong>n applying HA Item 112 andHA Item 168 can be successful. HA Item 112is preferred because from experience it is moreflexible than HA Item 116 and <strong>the</strong>refore lessprone to cracking because <strong>of</strong> <strong>the</strong> micaceousiron oxide pigmentation. It has also been foundthat <strong>the</strong> chlorinated rubber systems can havea powdery surface and <strong>this</strong> is best removed byslight sweep blasting before over coating with<strong>the</strong> epoxy system.”The choice <strong>of</strong> abrasive was also critical.Gerry Bourke <strong>of</strong> Scangrit said Olivine was<strong>the</strong> preferred option when blasting aboverivers: “Olivine AFS30 and Olivine AFS 20will achieve “Medium” blast pr<strong>of</strong>iles on mildsteel as defined by BS EN ISO 8503-1:1995.A medium blast pr<strong>of</strong>ile is defined as beingbetween 50 and 70 microns and up to 85micron.“<strong>In</strong> an independent Testing <strong>of</strong> ExpendableAbrasives conducted by PERA on behalf <strong>of</strong>Scangrit, Olivine AFS30 achieved a blast pr<strong>of</strong>ile<strong>of</strong> 52.9µm and Olivine AFS20 achieved a blastpr<strong>of</strong>ile <strong>of</strong> 68.5µm. The tests were conductedwith a compressor rated at 350cfm at 100psidelivery pressure. The blast nozzle was aventuri type having a nozzle bore <strong>of</strong> 3/8”.Pressure measured in <strong>the</strong> grit delivery hose,behind <strong>the</strong> blast nozzle, was 60psi.”For more information please contact: RHINOCEROS Limited, Huntingdon Works, Huntingdon Road, East Finchley, London, N2 9DXTelephone: 0208 444 6165 Fax: 0208 365 2865 Email: contracts@rhino247.co.uk Web: www.rhino247.co.uk10 14
FOCUSONcoating applicatorsFocusonconsultantsRHINOCEROS Manager Duncan J MacLeansays Olivine also has <strong>the</strong> advantage <strong>of</strong> being anatural mineral - in <strong>the</strong> event <strong>of</strong> a spill or a tearin <strong>the</strong> containment sheeting no environmentalcontamination would be caused. “<strong>In</strong> practice<strong>this</strong> has proved to be a smart move. Themen like it and say <strong>the</strong>y never want to goback to using copper slag. It has proved tobe highly efficient in removing <strong>the</strong> 6 coats<strong>of</strong> chlorinated rubber. The AFS30 or mediumgrit has proved to be ideal for sweep blasting<strong>the</strong> chlorinated rubber. The AFS20, a coarsergrade, has produced a pr<strong>of</strong>ile which exceedsthat required by <strong>the</strong> paint and has satisfied<strong>the</strong> client that his paint is going to stick to <strong>the</strong>bridge for a very long time!”After heating <strong>the</strong> area, it took over 100 tons <strong>of</strong>Olivine for blast cleaning, <strong>the</strong> waste having tobe vacuum cleaned <strong>of</strong>f <strong>the</strong> Terram protectivesheeting and hauled up to <strong>the</strong> road surface inlarge buckets.The first coating <strong>of</strong> Sigma 690 was applied byairless spray to a depth <strong>of</strong> 150 microns. Astripe coat over joints and rivets followed,using Sigma Micaceous Iron Oxide (MIO) to75 microns. This was covered with a fur<strong>the</strong>rfull sprayed coat <strong>of</strong> MIO to 150 microns, andfinally a top coat <strong>of</strong> Sigma 550 to 50 microns,in Belfast signature colour Neptune.The parapets and handrails were taken to baremetal SA 2.5, <strong>the</strong>n coated with Sigma 690,a stripe coat <strong>of</strong> Sigma 456, a fur<strong>the</strong>r spraycoating <strong>of</strong> Sigma 456 and a top coating <strong>of</strong>Sigma 550 in Blueberry and Turquoise.The Titanic continues to generate controversy;latest <strong>the</strong>ories suggest its hull failure mighthave been quickened due to excessive sulphurcontent in <strong>the</strong> steel. But above water levelBelfast is about to unveil a very attractiveexample <strong>of</strong> <strong>the</strong> best modern refurbishmenttechniques.Hankinson Painting GroupHankinson Restore Ancient StructureThe Blasting Division <strong>of</strong> Hankinson PaintingGroup were recently involved in <strong>the</strong>restoration <strong>of</strong> <strong>the</strong> main span <strong>of</strong> Powick NewBridge, a Grade II listed structure which carries<strong>the</strong> A449 over <strong>the</strong> River Teme, approximately2 miles South West <strong>of</strong> <strong>the</strong> City <strong>of</strong> Worcester.The bridge was built in 1837 and consists <strong>of</strong>two side spans and one main span – <strong>the</strong> mainspan taking <strong>the</strong> road across <strong>the</strong> river.The main span (approximately 21 metres inlength) consists <strong>of</strong> 7 No cast iron arch ribsand deck plates supported on sandstoneabutments. Access to <strong>the</strong> structure was carriedout using a fully encapsulated hung scaffold.Due to <strong>the</strong> environmentally sensitive location(river and flood plain) <strong>of</strong> <strong>the</strong> bridge no scaffoldcould be erected from ground level.Treatment <strong>of</strong> <strong>the</strong> structure consisted <strong>of</strong> fullfresh water wash down followed by abrasiveblasting <strong>of</strong> <strong>the</strong> cast iron using Garnet media(approximately 16 tonne). This was <strong>the</strong>nfollowed by applying a 5-coat epoxy paintsystem (approximately 950 litres in totalprovidedby Hempel Paints) and a compatiblemetal filler (approx. 60 litres) to all blowholes (honeycomb-which is common in castiron steelwork). All joints/interfaces weretreated using a compatible polysulphidesealant. External side elevations <strong>of</strong> <strong>the</strong> MainSpan were <strong>the</strong>n picked out in various colours,which were chosen by <strong>the</strong> client.Once all works were completed <strong>the</strong> scaffoldwas dismantled and all contact points wereprepared and treated by specialist rope accessoperatives.Although not a requirement <strong>of</strong> <strong>the</strong> contract,all procedures were carried out in accordancewith <strong>the</strong> National Highways Sector Schemefor <strong>Corrosion</strong> Protection <strong>of</strong> Ferrous Materialsby <strong>In</strong>dustrial Coatings (NHSS19A) and alloperatives were ICATS accredited.Operations Manager, Frank Kershawcommented “ The works to <strong>the</strong> Grade II listedstructure required not only <strong>the</strong> ability toperform technically challenging operationsbut also for our operatives to incorporate<strong>the</strong>ir artistic skills to complete <strong>the</strong> works to<strong>the</strong> crest heraldry. I would like to take <strong>this</strong>opportunity to commend <strong>the</strong> labour forcewho worked on <strong>the</strong> scheme”.All waste generated from <strong>the</strong> works wascollected and securely stored prior to removalto a suitably licenced waste transfer facility inaccordance with <strong>the</strong> Company’s ISO14001procedures.The contract has recently been shortlistedin <strong>the</strong> <strong>In</strong>dustrial Category <strong>of</strong> <strong>the</strong> Painting &Decorating Association Premier Trophy Awards.Main Supplier Details:-Item: Protective CoatingsSupplier: Hempel PaintsMaterials:Item 115 - Hempadur Mastic 8588E - 19910Item 116 (Stripe) - Hempadur Mastic 8588EItem 116 - Hempadur Mastic 8588E - 17050Item 116 (Stripe) - Hempadur Mastic 8588EItem 169 - Hempathane Topcoat 5521E – 12-B-21Special/O<strong>the</strong>r Products Used:-Item: Metal FillerSupplier: Hempel PaintsMaterial: Hempel ProFiller 35370Item: Polysuphide SealantSupplier: Adshead RatcliffeMaterial: Arbokol 1000For more information please contact: Central House, Lyng Lane, West Bromwich, West Midlands B70 7RW Telephone: 0870 789 2020email: sales@hankinson.co.uk website: www.hankinson.co.uk11 15