13.07.2015 Views

CERTI-VEX AC25 - Vexcon Chemicals

CERTI-VEX AC25 - Vexcon Chemicals

CERTI-VEX AC25 - Vexcon Chemicals

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CS119 – 12-04<strong>CERTI</strong>-<strong>VEX</strong> ® <strong>AC25</strong>ACRYLIC CONCRETE CURING AND SEALING COMPOUNDASTM C-1315 • GLOSSVOC compliant: 285 GR./Liter or 2.38#/Gal. Cure & SealDESCRIPTION<strong>CERTI</strong>-<strong>VEX</strong> <strong>AC25</strong> is a 100% styrene acrylic co-polymerbased curing, sealing, hardening, dustproofing and waterrepellent compound. When applied, it quickly dries to a hardclear film that is tough, chemical resistant, long lasting andglossy. The product is ideal for use on interior and exteriorfloors, walls, architectural sections and as a base coat for avariety of top coatings.Certi-Vex <strong>AC25</strong> forms a clear film thatprovides superior shine that enhances the appearance ofarchitectural concrete.Certi-Vex <strong>AC25</strong> is formulated from customized styreneacrylic resins manufactured by <strong>Vexcon</strong> <strong>Chemicals</strong> especiallyfor use on cementitious surfaces. The formulation contains nomodifiers or extenders that can cause cure and seal to yellow,blush or look non-glossy. Certi-Vex <strong>AC25</strong> provides anexcellent base for most adhesives, paints and a variety oftopcoats. The product acts as a prime coat considerablyimproving adhesion to and preventing lifting of paint, tileadhesives, elastomeric coatings and other toppings. Theseproducts meet the requirements of the Tile Adhesion Test ofthe Resilient Tile Institute and the Tile Adhesion TestRequirements of ASTM-C-1315BENEFITS• Economical ASTM 1315 sealer• Provides for complete development of concrete• Certi-Vex <strong>AC25</strong> may be applied to damp but not wetsurfaces• Seals and hardens surface reducing cleaning andmaintenance• Excellent protection against staining, attack by alkali, oil,cleaners and common industrial chemicals• Prevents efflorescence, dusting and spalling• Breathable• Quick drying• Excellent base for adhesives• Re-coatable and paintable• Seals stamped and decorated concrete.• Apply to damp surfaces without whitening or loss ofadhesion• Surfaces look newer and brighter• Can apply to 20° FAPPLICATIONProduct is supplied at the proper consistency for application, anddilution will reduce efficiency. Thoroughly mix before applying.Apply by low-pressure high solids commercial grade sprayer withneoprene fittings. The sprayer must be clean, dry and free of solvents.If cleaning with solvents is required, use Certi-Vex ® EquipmentCleaner and flush thoroughly with water before use. Clean sprayer asdirected between applications to ensure best results. If sprayer is notavailable, use a brush or ¼” roller. If using a roller or applicator, donot overwork the material. Coat in one direction only. Overworkedmaterial can become stringy and gum up. Coat uniformly leaving nogaps, slips or excess. Material should not be allowed to puddle. Toprotect the sealed floor from ongoing construction dust, dirt anddebris, use Certi-Vex ® Talc Release, data sheet #OP132 until allconstruction work is completed. UseCerti-Vex ® Grip, data sheet#OP115 to improve non-slip profile.CURING AND SEALING NEW CONCRETEApply Certi-Vex <strong>AC25</strong> to still damp freshly finished concreteas soon as the surface cannot be marred and water sheendisappears. Do not apply over free standing water. Ifapplication is delayed, concrete must be kept wet (preferablyby water spray mist) until product can be applied. If concreteis allowed to dry use Certi-Vex ® Concrete Etch &Efflorescence Remover to clean and prepare the surface.Apply first coat at 300 sq.ft. /gal (7.5 m 2 /L) on porous floors.A second coat is recommended for long term durability. SeeSecond Coat section.SEALING EXISTING CONCRETETo provide long term protection and a glossy shine, apply tosurfaces that are properly repaired and structurally sound andcleaned of all dirt, oil, grease and foreign matter. Use one of<strong>Vexcon</strong>’s concrete cleaners and stain removal products toproperly clean the surface prior to application. Use Certi-Vex ®Concrete Stripper to remove old sealers, epoxies, urethanes,adhesives, curing compound and floor waxes. Prior to applicationa test area must be performed to determine proper application rateand required surface preparation. To determine that the concrete ispenetrable perform a water absorbency test by applying water to arepresentative portion of the prepared concrete floor. A properlyprepared surface when dry will immediately absorb clean waterwithout any surface beading effects. If required use Certi-VexEtch & Efflorescence Remover to improve sealerpenetration.Apply Certi-Vex<strong>AC25</strong> as directed above at 400-500sq.ft. /gal (10-12.5 m 2 /L) on hard non-porous floors and 250-300sq.ft. /gal (6.2-7.5 m 2 /L) on porous floors. A second coat isrecommended for long term durability and gloss. See Second Coatsection.


SECOND COATAfter application of the first coat a second coat may beapplied when the surface has dried. Apply second coat at 400-500 sq.ft. /gal (10-12.5 m 2 /L).MAINTENANCESpills should be removed promptly and cleaned with a highquality commercial detergent. Floors should be cleanedregularly. Periodic reapplication may be required as the sealerwears off.TOPCOATS AND ADHESIVESCerti-Vex <strong>AC25</strong> cured concrete can be topcoated with avariety of paint, adhesives and mastics, a minimum of 28 daysafter application. It is strongly suggested that a test area beapplied prior to coating the entire surface, since products canadhere to concrete in varying degrees. Concrete cured withCerti-Vex <strong>AC25</strong> is typically topcoated without incident,however, it is advisable to check with the manufacturer of thetopcoat for any precautionary information.SPECIFICATIONS/COMPLIANCE• ASTM C 1315 Type 1, Class B• AASHTO M-148• ASTM C 309 Type 1 Class A&B• Federal specification TTC0800A (GSA FSS) Type 1.• USDA, ADA and ASTM 2047 non-slip• Passes 500 hours weatherometer resistance as measured byASTM G53Test reports are available upon request.SPECIAL NOTES• To assist in application 200 sq.ft. /gal wet film isapproximately equal to the thickness of a sheet of paper• Will tend to show rubber burns or tire marks• Will cause bleeding of bituminous surfaces• May cause mottling of colored surfaces• Not gasoline resistant. Use <strong>Vexcon</strong> Powercoat ® GR• Application of more than two coats is not recommended• Over application may lead to surface discoloration andimproper sealer performance.• Mix well before use.• Keep from freezing.• Do not apply more material per square foot thanspecified.• Can apply when surface temperatures are 20° F - 85° F,when below or above these ranges review <strong>Vexcon</strong>'s Coldand Hot Weather Application Guides.• If properly stored in its original sealed container, threeyears from date of manufacture.Rotate your stock.• For use by experienced professionally trained applicatorsPACKAGINGCerti-Vex AC 25 is available in 55-gallon drums and 5-gallonpails. Contact <strong>Vexcon</strong> directly to discuss your customizedpackaging requirements.VITAL STATISTICS• Flash Point (TCC):106º F (41ºC)• Boiling Point (706 mmHg): 310-403 F (154-207ºC)• Autoignition Temp:Above 473º F (245ºC)• Extinguishing Media: Foams, Dry Chemical, C02,• Water may be used to reduce the rate of burning and forcooling containers.PHYSICAL PROPERTIES• Wet appearance Water White• Dry appearance Clear• Dry to touch 45 minutes• Dry - tack free 85 minutes• Foot traffic 24 hours• Vehicle traffic 72 hours• Solids 25% minimumNote: All calculations based upon 68-77° F (20-25° c).Lower temperatures and relative humidity will extend drytimes.HEALTH AND SAFETY• Use only with adequate ventilation.• Use of gloves, goggles and other protective clothing isadvised when using this product.• If swallowed, do not induce vomiting.• Use of respirators is advised when using in confinedareas.<strong>Vexcon</strong> MSDS #CS119 is an integral part of the safety andapplication of our product. A short synopsis is provided in thisproduct data sheet. Before using this <strong>Vexcon</strong> product, it isadvisable to obtain a copy of the MSDS from your distributoror by contacting <strong>Vexcon</strong> <strong>Chemicals</strong>.CONTACT US @Additional product information, technical assistance andcustomer service is available by contacting <strong>Vexcon</strong> <strong>Chemicals</strong>directly or our distributors.• www.vexcon.com• Technicalservice@vexcon.com• Customerservice@vexcon.com• Sales@vexcon.com• Voice: 888.839.2661• Fax: 215.332.9997

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!