13.07.2015 Views

Allen Bradley PowerFlex 40 Quick Start Manual - cemco * electric , inc

Allen Bradley PowerFlex 40 Quick Start Manual - cemco * electric , inc

Allen Bradley PowerFlex 40 Quick Start Manual - cemco * electric , inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

See the <strong>PowerFlex</strong> <strong>40</strong> User <strong>Manual</strong> on CD for more information on parameters.English-15Smart <strong>Start</strong>-Up with Basic Program Group ParametersThe <strong>PowerFlex</strong> <strong>40</strong> is designed so that start up is simple and efficient. The Program Groupcontains the most commonly used parameters.= Stop drive before changing this parameter.No. Parameter Min/Max Display/Options DefaultP031 [Motor NP Volts] 20/Drive Rated Volts 1 VAC Based on Drive RatingSet to the motor nameplate rated volts.P032 [Motor NP Hertz] 15/<strong>40</strong>0 Hz 1 Hz 60 HzSet to the motor nameplate rated frequency.P033 [Motor OL Current] 0.0/(Drive Rated Amps×2) 0.1 Amps Based on Drive RatingSet to the maximum allowable motor current.P034 [Minimum Freq] 0.0/<strong>40</strong>0.0 Hz 0.1 Hz 0.0 HzSets the lowest frequency the drive will outputcontinuously.P035 [Maximum Freq] 0/<strong>40</strong>0 Hz 1 Hz 60 HzSets the highest frequency the drive will output.P036 [<strong>Start</strong> Source] 0/6 0 = “Keypad” (1)0Sets the control scheme used to start the drive.1 = “3-Wire”2 = “2-Wire”(1)When active, the Reverse key is also active3 = “2-W Lvl Sens”unless disabled by A095 [Reverse Disable].4 = “2-W Hi Speed”5 = “Comm Port”6 = “Momt FWD/REV”P037 [Stop Mode] 0/9 0 = “Ramp, CF” (1)0Active stop mode for all stop sources [e.g. keypad,run forward (I/O Terminal 02), run reverse (I/OTerminal 03), RS485 port] except as noted below.Important: I/O Terminal 01 is always a coast tostop input except when P036 [<strong>Start</strong> Source] is setfor “3-Wire” control. When in three wire control, I/OTerminal 01 is controlled by P037 [Stop Mode].1 = “Coast, CF” (1)2 = “DC Brake, CF” (1)3 = “DCBrkAuto,CF” (1)4 = “Ramp”5 = “Coast”6 = “DC Brake”7 = “DC BrakeAuto”8 = “Ramp+EM B,CF”9 = “Ramp+EM Brk”(1) Stop input also clears active fault.P038 [Speed Reference] 0/7 0 = “Drive Pot”1 = “InternalFreq”Sets the source of the speed reference to the2 = “0-10V Input”drive.3 = “4-20mA Input”Important: When A051 or A052 [Digital Inx Sel] isset to option 2, 4, 5, 6, 13 or 14 and the digitalinput is active, A051, A052, A053 or A054 willoverride the speed reference commanded by thisparameter. Refer to Chapter 1 of the <strong>PowerFlex</strong> <strong>40</strong>User <strong>Manual</strong> on CD for details.4 = “Preset Freq”5 = “Comm Port”6 = “Stp Logic”7 = “Anlg In Mult”01 (IP66, Type 4X)P039 [Accel Time 1] 0.0/600.0 Secs 0.1 Secs 10.0 SecsSets the rate of accel for all speed <strong>inc</strong>reases.P0<strong>40</strong> [Decel Time 1] 0.1/600.0 Secs 0.1 Secs 10.0 SecsSets the rate of decel for all speed decreases.P041 [Reset To Defalts] 0/1 0 = “Ready/Idle”0Resets all parameter values to factory defaults.1 = “Factory Rset”P042 [Voltage Class] 2/3 2 = “Low Voltage” (480V)3Sets the voltage class of 600V drives.3 = “High Voltage” (600V)P043 [Motor OL Ret] 0/1 0 = “Disabled”01 = “Enabled”Enables/disables the Motor Overload Retention function.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!