Product Specifications24Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.Schematics (cont.)LINE HOT120 VACLINE NEUFPFLAMESENSORPROBE.00051MIGNNIGNITORLOWHEATK7IGNHIGHHEATK2Q22GNDK1CIRCULATORBLOWERCOOLC2 STAGEGAS VALVEMVCOMPMPARKH1MVLW8K6PS2CIRC.NEUPS12ND STAGEPRESSURESWITCHHLOHIGHLIMITELECTRONICAIR CLEANEREACEACNEUROLLOUTSWITCH1ST STAGEPRESSURESWITCHMATE WITH AMP1-480708-0USINGSOCKETS350550-13 AMPAUTOMOTIVEFUSETYPICAL SCHEMATICTypical SchematicAMV9/ACV9_____X* MODEL FURNACESWR 50V61-289 AMV9***/ INTEGRATED ACV9*** Model IGNITION Furnaces CONTROLThis schematic is for reference only. Not all wiring WR 50V61-289 is as shown Integrated above. Refer Ignition to the appropriate Control wiring diagram for the unit being serviced.This schematic is for reference only. Not all wiring is as shown above.Refer to the appropriate wiring diagram for the unit being serviced.INDHIK3INDUCERINDLOK8aAUXLIMITINDNEUHLIHUMHUMIDIFIERK8bMVHHUMNRTRB/CYGTHXFMRXFMRNW2W124 V.A.C.YGW2W1THERMOSTATRHIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.SCHEMATICSSS-AMV9 www.amana-hac.com 13