13.07.2015 Views

Electrical and Electro-chemical Characterization Laboratory

Electrical and Electro-chemical Characterization Laboratory

Electrical and Electro-chemical Characterization Laboratory

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Electrical</strong> <strong>and</strong> <strong>Electro</strong>-<strong>chemical</strong><strong>Characterization</strong> <strong>Laboratory</strong>www.udri.udayton.eduThe UDRI Carbon Group operates a state-of-the-art facility forcharacterizing the electrical <strong>and</strong> electro-<strong>chemical</strong> properties ofmaterials such as nanocomposites, coatings, fuel cell materials, etc.Capabilities include commercially available equipment as well ascustom-developed techniques for specialized measurements <strong>and</strong>quality control. The group offers testing services to industrial,government, <strong>and</strong> academic customers looking for high-quality materialscharacterization data.Instrument CapabilitiesRastering 4-Point Probe Surface Resistivity Profiler• Custom apparatus <strong>and</strong> program allows for the testing of amatrix of points across the two-dimensional surface of asample• Measures resistance, resistivity, surface resistivity, <strong>and</strong>volume resistivity of a solid sample• Four-point probe model Loresta-GP MCP-T600, 1 cm pinspacing• Measurement range from 9.999x10 -3 to 9.999x10 7 ?• Maximum 8 in. x 8 in.• Software displays surface profile based on matrix data256-pin Array Surface Resistivity Profiler• Custom apparatus measures through- <strong>and</strong> in-planeresistance <strong>and</strong> resistivity of a solid sample.• Spring loaded pins allow flat or uneven surfaces to beanalyzed• Pin spacing is 1 cm. Additional resolution can be producedby rastering the sample• Software displays surface profile based on matrix data• Maximum sample size 9” x 9”©2010 University of Dayton Research Institute


Shaping the Technology of Tomorrowwww.udri.udayton.eduHigh Current Potentiostat & Galvanostat• Model Frequency Research Inc. (FRI) Parstat 2273• Useful for testing fuel cells <strong>and</strong> super capacitors, applyingmetal coatings, as well as a number of other electro<strong>chemical</strong>applications• Max. current: 2 A, with the ability to boost to 20 A• Input impedance >10 13 Ohms• Capacitance

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!