Solenoids• Aluminum body• NBR seals• Manual override• High flow: 1.8 CV• 1/2” conduit connection to coil• 1/4” port size• Body can be converted between 5/2(double acting) <strong>and</strong> 3/2 (spring return)• Coils <strong>and</strong> flange tubes are rated to CSA/UL• Same body accepts NEMA 4, NEMA 7, <strong>and</strong>ATEX coils• Voltage options available upon requestMANUALOVERRIDEWWEATHER PROOFCOIL NEMA 4XSC4**L2A AL1(2) M5 SCREWS X40MM LONGEXPLOSION PROOFCOIL NEMA 7SC7**H21.84[.86]35.97[1.42]TRANSITION PLATE(IF REQUIRED)AIR INLET (Port 1)GØ 5.5 mm [.22 IN](2) MOUNTING HOLESPLUG PLACED HEREFOR 5/2 OPERATION(SINGLE OPERATOR ONLY)FF1G1Ø 5.5 mm [.22 IN] X3.3 mm [.13 IN] DEEPLOCATING HOLEPLUG PLACED HEREFOR 3/2 OPERATION(SINGLE OPERATOR ONLY)Setup Unit A C F F1 G G1 H L1 L2 WSinglein 0.88 0.75 1.25 0.63 0.94 0.47 1.25 6.151.65-mm 22.2 19.1 32.0 16.0 23.9 11.9 31.7 157 41.9Doublein 0.88 0.75 1.25 0.63 0.94 0.47 1.258.55 1.65-mm 22.2 19.1 32.0 16.0 23.9 11.9 31.7 217 41.923ConnectorsDIN 43650IndustrialForm B Maximum Cable Diameter: 9mm (0.35”)TypeStrain Reliefwithout CordStrain Relief with Light100-240 AC6-48 AC/DC48-120 DC(Not polarity dependent)1/2” Conduitwithout CordStrain Relief with Light & 6’ Cord100-240 AC6-48 AC/DC48-120 DCPart Number SR7020-001 SRL7020-AA SRL7020-DB DIN PLUG SRLC-7094-006 SRLC-7094-007SHARPE ® PRODUCTS • TOLL FREE (877) 774-2773 • FAX (708) 562-9250 • www.sharpevalves.com
Solenoids Electrical InformationCoil Part Number**=VoltageDescriptionCoil Part NumbersOperatorTypeInstructionsLbSC4**Weather-ProofDIN 43650 Industrial Form B Connection NEMA 4XWOrder coil separately(specify voltage code from below)0.12SC4**CSC4**CT(high temp 82°C max)Weather-Proof1/2” Conduit with 30” LeadsNEMA 4XWOrder coil separately(specify voltage code from below)0.12SC7**Explosion-Proof1/2” Conduit with 24” LeadsCSA & FM ApprovedCL. I; Zone1 Ex m II T4; AEx m IICL. I; Div.1; GR. A, B, C, DCL. II; GR. E, F, G CL. IIIT4 Ta=-20°C to +60°CNEMA 4, 4X, 7C, 7D, 9WOrder coil separately(specify voltage code from below)0.44SCI2DIntrinsically-SafeStrain Relief Ex iaCL. I; GR. A,B,C,DCL. II; GR.E,F,GCL. III; Div.1; T5VCoil <strong>and</strong> Connector included withvalve (24VDC only)SCI2D Must be Used with anIntrinsically-Safe Barrier0.46**Code2A1222OperatorTypeVoltage+/-10%22/5024/60110/50120/60220/50240/60InrushCurrent (Amps)Voltage CodesHoldingLower Wattage available, upon requestResistance(OHMS @ 25°C)Power(AC=VA, DC=Watts)W V Z W V Z W V Z W V ZNEMA ATEX NEMA ATEX NEMA ATEX NEMA ATEX4, 4x 7, 9 Ex ia Ex m 4, 4x 7, 9 Ex ia Ex m 4, 4x 7, 9 Ex ia Ex m 4, 4x 7, 9 Ex ia Ex m.40 - - - .40 - - - 31 - - - 4.8 - - -.08 .096 - - .06 .054 - .029 840 530 - 1164 4.8 6.5 - 3.0.04 .048 - - .03 .027 - .015 3310 2345 - 6730 5.9 6.5 - 3.01D 12 VDC .40 - - - .40 .375 - .267 31 32 - 45 4.8 7 - 3.52D 24 VDC .20 - .05 .136 .20 .187 .05 .136 121 128 275 177 4.8 - 1.6 3.5Fig: X2003AAWR-I-2DDescription: Coil Right - Intrinsically Safe - 24 VCDS2003ACWRX2003AAWRSolenoids Part Number ChartBody NEMA CLASS VoltageCOIL LEFT FOR SPNII AND OTHERACTUATORS THAT REQUIRE AIR TO COME INON THE LEFT IN SPRING RETURN MODECOIL RIGHT FOR X AND OTHER ACTUATORSTHAT REQUIRE AIR TO COME IN ON THERIGHT IN SPRING RETURN MODE4 4 = NEMA 4X 12 12 = 120 VAC7 7 = NEMA 7/9 22 22 = 240 VACI I = INTRINSICALLY SAFE - 24VDC ONLY 2A 2A = 24 VACS M ITH-COOPER IN TERN ATIONAL ® • (800) 766-0076 • FAX (323) 890-4456 • www.smithcooper.com 241D2D1D = 12 VCD2D = 24 VCD