13.07.2015 Views

testo 300 M, professional flue gas analyser

testo 300 M, professional flue gas analyser

testo 300 M, professional flue gas analyser

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

88Practical accessories°CEconomical software, Windows® software for datamanagementWith convenient analysis and graphics function,online measurement and barcode printoutPart no. 0554 0310SoftCase (protects instrument from dirt andimpact) made of plastic, with carrier strap andmagnetic plateCan be positioned on boiler, for examplePart no. 0516 0301Compact <strong>gas</strong> drier, basic versionPart no. 0632 3370Compact <strong>gas</strong> drier, comfort versionPart no. 0632 3371For <strong>testo</strong> <strong>300</strong> XLAttachable printerPart no. 0554 0570SoftCase (protects printer from dirt/impact)Part no. 0516 0411Vol.% O2ppmCOVol. %CO2ppmNOλTesto printer with 1 roll of thermal paper and 4 AAsize batteriesPrints readings on locationPart no.0554 0545Spare NO measuring cellQuick and easy replacement of measuring cell byuserPart no. 0390 0074Smoke tester with oil, soot sheet for measuringsoot in <strong>flue</strong> <strong>gas</strong>Part no.0554 0307For <strong>testo</strong> <strong>300</strong> XLBarcode pen to read in measurement locationsQuick and accurate allocation of reading to sitePart no.0554 0460∆PeffgeffnOrdering data for <strong>testo</strong> <strong>300</strong> M/XLCable, 1.5 m long, connects probe with plug-in head to meas. instrumentPUR coating materialPart no.<strong>testo</strong> <strong>300</strong> M, <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong>, with rech. batt. and calibration protocol 0563 0310Measures O2, CO2, CO (H2 compensated), effg/effn, draught/pressure, differential pressure, °C<strong>testo</strong> <strong>300</strong> XL, <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong>, incl. rech. battery and calibration protocol 0563 0<strong>300</strong>Measures O2, CO2, CO (H2 compensated), CO (ambient), effg/effn, draught/pressure, differentialpressure, CH4, °C, differential temperatureMains unit 230 V/ 8 V/ 1 A, for instrument (European plug)0554 1084For mains operation and battery rechargingNO measuring cell0440 3922Built-in in <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong>NO measuring cell (upgrade)0554 3922For subsequent installation in <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong>Spare CO measuring cell0390 0072Quick and easy replacement of measuring cell by userSpare NO measuring cell0390 0074Quick and easy replacement of measuring cell by userSpare O2 measuring cellTesto printer with 1 roll of thermal paper and 4 AA size batteriesPrints readings on locationSpare thermal paper for printer (6 rolls)Recharger for printer (with 4 standard rech. batt.)Rechargeable batteries are recharged externallyCar charging adapter, ready to measure following recharging in carBattery is recharged while travelling in carHose connection set, incl. silicone hose and connection adapterFor separate <strong>gas</strong> pressure measurementSmoke tester with oil, soot sheet for measuring soot in <strong>flue</strong> <strong>gas</strong>PC software and accessories0390 00700554 05450554 05690554 01100554 04240554 03150430 01430554 0307Economical software, Windows® software for data management0554 0310With convenient analysis and graphics function, online measurement and barcode printoutRS232 cable0409 0178Connects instrument to PC (1.8 m) for data transferOrdering data for AccessoriesSpare particle filter for <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong> (10 off)Filter paper to determine smoke number40 strips for approx. 200 measurementsSoftCase (protects instrument from dirt and impact) made of plastic, with carrierstrap and magnetic plateTransport case (leather) for instrument, probes and accessoriesRobust, spacious case made of real leatherAluminium case for instrument, probe and accessoriesProbes in lid make it easy to find parts in caseTransport case (plastic) for measuring instrument, probesMeasurement case (leather) with drawers for instruments and accessoriesSystem case for <strong>analyser</strong>, probes and accessoriesProduct line system case with small plastic boxes without contents, attachableto system case 0516 0310Tools system case with tools bag without contents, attachable to system case0516 0310Universal system case without sections, attachable to system case 0516 0310Part no.0554 33710554 03080516 03010516 03060516 0<strong>300</strong>0516 0303ISO calibration certificate/Flue <strong>gas</strong>0520 0003Calibration points 2.5% O2; 100 and 1000 ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2Ordering data for <strong>gas</strong> drierCompact <strong>gas</strong> drier, basic version0632 3370For measurements with a high condensate level (manual condensate emptying)Compact <strong>gas</strong> drier, comfort version0632 3371For measurements with a high condensate level and long-term measurements (automatic condensate emptying)Mains unit for compact <strong>gas</strong> drier and <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong>0554 1143Current connection cable, connects <strong>gas</strong> drier to <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong>Supplies power to <strong>flue</strong> <strong>gas</strong> <strong>analyser</strong> via the compact <strong>gas</strong> drier mains unitSpare particle filter for compact <strong>gas</strong> drier (5 off)0516 01000516 03100516 03280516 03290516 03310449 00340554 3370

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!