13.07.2015 Views

BCA Green Mark for Existing Schools Version 1.0 - Building ...

BCA Green Mark for Existing Schools Version 1.0 - Building ...

BCA Green Mark for Existing Schools Version 1.0 - Building ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>BCA</strong> <strong>Green</strong> <strong>Mark</strong> <strong>Version</strong> ES/<strong>1.0</strong> <strong>Existing</strong> <strong>Schools</strong> Criteria (<strong>Version</strong> 1)Energy Related RequirementsPart 1 - Energy Efficiency (Total Points: 87)<strong>Green</strong> <strong>Mark</strong> Points1-1 Energy Efficiency (10 points)(a) To achieve increased building energyefficiency against similar building types topromote efficient use of energy.Option AOption A is applicable <strong>for</strong> buildings where energybenchmarks are not available. Energy savingsover its own historical baseline over the last threeyears must be demonstrated.Option B- EUI of 46.5 kWh/m2/yr <strong>for</strong> Primary schools- EUI of 42 kWh/m2/yr <strong>for</strong> Secondary schools- EUI of 65 kWh/m2/yr <strong>for</strong> Junior CollegesOption A2 points <strong>for</strong> achieving 5% energysavings from own historical baseline0.3 point <strong>for</strong> every subsequent percentageimprovement from baseline of 5% energysavingsOption B2 points <strong>for</strong> achieving the stated energybenchmarks0.1 point <strong>for</strong> every subsequent percentileimprovement from baseline of the statedenergy benchmarks. See Appendix A <strong>for</strong>percentile graph.(up to 10 points)1-2 Percentage of non air-conditioned areasbased on total GFA (10 points)0.1 point <strong>for</strong> every percentage of non airconditionedareas excluding carpark areas(up to 10 points)Pre-requisite Requirement: 5 pointsfrom this section1-3 <strong>Building</strong> Orientation and NaturalVentilation (15 points)(a) Minimum direct west facing façade throughbuilding design orientation.Note: Orientation of façade that falls within the range of 22.5° N ofW and 22.5° S of W will be defined as west facing facade. Corewalls <strong>for</strong> lifts or staircases and toilets that are located within thisrange are exempted in computation.Applicable to Naturally Ventilated <strong>Building</strong>AreasPoints awarded = 5 – 0.1 x (% of westfacing facade areas over total façadeareas)(Up to 5 points)Where there is no west facing façade, thetotal points awarded <strong>for</strong> this item will be 15points; the items 1-3 (b)(i) and (b)(ii) aslisted below will not be applicable.(b)(i) Minimum west facing window openings.Points awarded = 2.5 - 0.1 x (% of westfacing window areas over total west facingfaçade areas)Effective Date: 1 Sept 2011 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!