13.07.2015 Views

BCA Green Mark for Existing Schools Version 1.0 - Building ...

BCA Green Mark for Existing Schools Version 1.0 - Building ...

BCA Green Mark for Existing Schools Version 1.0 - Building ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>BCA</strong> <strong>Green</strong> <strong>Mark</strong> <strong>Version</strong> ES/<strong>1.0</strong> <strong>Existing</strong> <strong>Schools</strong> Criteria (<strong>Version</strong> 1)(b)(ii) Effective sunshading provision <strong>for</strong> windowson the west façade with minimum shadingof 30%.(c) Proper design of building layout that utilizesprevailing wind conditions to achieveadequate cross ventilation.Points awarded = 0.025 x (% of westfacing window areas with sunshadingdevices over total west facing façadeareas)(Up to 5 points <strong>for</strong> 1-3 b(i) & b(ii))0.5 point <strong>for</strong> every 10% of units withwindow openings facing north and southdirectionsPoints awarded = 0.5 x (% of units /10)(up to 5 points)Pre-requisite Requirement: 12 pointsfrom this section1-4 Active Design (15 points)a) Mechanical fan systemPower budget (W/m 2 ) <strong>for</strong> the mechanicalventilation system should be calculated.Applicable to Air-conditioned/MechanicalVentilated <strong>Building</strong> Areas (>500m 2 )2 points <strong>for</strong> achieving Efficiency of 0.47 Wper m 3 /h <strong>for</strong> constant air volume fan and0.74 W per m 3 /h <strong>for</strong> variable air volume fan1 point <strong>for</strong> every subsequent 1%improvement from 0.47 W per m 3 /h or 0.74W per m 3 /h(Up to 15 points)OR(b) Unitary Air-Conditioners/CondensingUnits/Air-Cooled Centralised Plant : Single-Spilt Unit Multi-Spilt Unit Variable Refrigerant Volume (VRV) System Air-cooled Chiller and pumps Packaged Units*If all unitary air conditioners are rated minimum2 ticks under the NEA Energy Labeling Scheme,7 points will be awarded.1-5 Lighting System (13 points)To encourage optimization of lighting systemefficiency(a) Lighting power budgetOR2 points <strong>for</strong> achieving Efficiency of 2.4COP1 point <strong>for</strong> every subsequent 0.1 COPimprovement from 2.4 COP(Up to 15 points)Note: Where there is a combination of (a)and (b), the computation of the pointsawarded will be based on the pro-ration ofpoints based on floor area ventilated byactive design6 points <strong>for</strong> achieving lighting densityof 15% better than lighting powerbudget in SS5300.2 point <strong>for</strong> every subsequent percentageimprovement from baseline lighting densityof 15% better than lighting power budget inSS530Points awarded = 0.2 x (% improvement15% better than lighting power budget inSS530)(Up to 10 points)Effective Date: 1 Sept 2011 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!