Overcurrent ProtectionFusingPrimary fuses F1 and F2, IEC(5 X 20 mm size) time lag/slow blowtype, 250V rated, 12A (100/120V)/6.3A (220/230/240V)Light Source• Tungsten-halogen lamp,50 watt, 12 volts• Tungsten-halogen lamp, TL 2 1 ⁄2,15 watt, 10.5 voltsClearance needed toperform maintenance24”4.5”9.25”17.25”38.5” W x 34” D22.5”Display2-line, 20-character alphanumericvacuum fluorescence display.Temperature ControlSet by computer at 35º C ± 1º CBar CodeCode 39 Standard Conformance11”11”18.75”1.75”The WA feet are 1.5” diameter6” clearance needed in backfor direct water hookupPerformancePanel Capacity for<strong>WalkAway</strong>-40 <strong>plus</strong> System40 MicroScan ® panels with 96 wellseach of any type compatible with theincubator environment; up to eightpanel towers with five panels each.Panel Capacity for<strong>WalkAway</strong>-96 <strong>plus</strong> System96 MicroScan panels with 96 wellseach of any type compatible with theincubator environment; up to eightpanel towers with 12 panels each.Incubation Temperature Stability±1º CReagent Type Capacity10 reagents totalReagent Dispense Volume (µl)15 to 75, depending on reagent dispensedOil Dispense Volume (µl)60 to 150Operator InterfaceFront panel controls and PC keyboard,monitor, and LabPro software.Information contained herein applies only to the <strong>WalkAway</strong> <strong>plus</strong> instrument and not to the LabProcomputer system or printers. <strong>Specifications</strong> are for <strong>WalkAway</strong> <strong>plus</strong> instrumentation only and do notreflect current peripheral equipment.<strong>WalkAway</strong> ® , MicroScan ® and all associated marks are trademarks of <strong>Siemens</strong> <strong>Healthcare</strong> DiagnosticsInc. All other trademarks and brands are the property of their respective owners. Product availabilitymay vary from country to country and is subject to varying regulatory requirements. Please contactyour local representative for availability.<strong>Siemens</strong> Global Headquarters<strong>Siemens</strong> AGWittelsbacherplatz 280333 MuenchenGermanyGlobal <strong>Siemens</strong><strong>Healthcare</strong> Headquarters<strong>Siemens</strong> AG<strong>Healthcare</strong> SectorHenkestrasse 12791052 Erlangen, GermanyTelephone: +49 9131 84 - 0www.siemens.com/healthcareGlobal Division<strong>Siemens</strong> <strong>Healthcare</strong> Diagnostics Inc.1717 Deerfield RoadDeerfield, IL 60015-0778USAwww.siemens.com/diagnosticswww.siemens.com/diagnosticsOrder No. A91DX-0701604-GC1-4A00 | Printed in USA | © 2009 <strong>Siemens</strong> <strong>Healthcare</strong> Diagnostics Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!