13.07.2015 Views

Keithley 2400 Datasheet - Testwall

Keithley 2400 Datasheet - Testwall

Keithley 2400 Datasheet - Testwall

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>2400</strong> Series SourceMeter ® LineSOURCE AND MEASURE Tightly coupled precision sourcing and measurementOrdering Information<strong>2400</strong> 200V, 1A, 20WSourceMeter<strong>2400</strong>-C 200V, 1A, 20WSourceMeter withContact Check<strong>2400</strong>-LV 20V, 1A, 20WSourceMeter2410 1100V, 1A, 20WSourceMeter2410-C 1100V, 1A, 20WSourceMeter withContact Check2420 60V, 3A, 60WSourceMeter2420-C 60V, 3A, 60WSourceMeter withContact Check2425 100V, 3A, 100WSourceMeter2425-C 100V, 3A, 100WSourceMeter withContact Check2430 100V, 10A, 1000W PulseMode SourceMeter2430-C 100V, 10A, 1000W PulseMode SourceMeterwith Contact Check2440 40V, 5A, 50WSourceMeter2440-C 40V, 5A, 50WSourceMeter withContact CheckExtended warranty, service, andcalibration contracts are available.Accessories SuppliedTest LeadsLabVIEW Software Driver(downloadable)LabTracer Software(downloadable)TestPoint Software Driver(downloadable)1.888.KEITHLEY (U.S. only)www.keithley.comI-V CharacteristicsAll SourceMeter instruments provide four-quadrant operation. In the first and third quadrants theyoperate as a source, delivering power to a load. In the second and fourth quadrants they operate as asink, dissipating power internally. Voltage, current, and resistance can be measured during source or sinkoperation.I sourceI meterV meter/ComplianceLocalRemoteRemoteLocalIN/OUT HISENSE HISENSE LOIN/OUT LOSource I, Measure V, I, or Ω configuration–200V+1A+100mA–20V +20V +200V<strong>2400</strong>only–100mA–1A<strong>2400</strong>onlyModel <strong>2400</strong> and <strong>2400</strong>-LV SourceMeter+3A+1A+100mA–60V –20V +20V +60V–100mA–1A–3AModel 2420 3A SourceMeter–100V+10A+3A+1A+100mA–60 –20 +20 +60 +100V–100mA–1A–3A–10ADuty cyclelimitedDuty cyclelimitedDUTDuty cyclelimitedPulse modeonlyModel 2430 1kW Pulse Mode SourceMeterI meter/ComplianceA G R E A T E R M E A S U R E O F C O N F I D E N C EV sourceFeedback toAdjust V sourceV meterLocalRemoteRemoteLocalIN/OUT HISENSE HISENSE LOIN/OUT LOSource V, Measure I, V, or Ω configuration–1100V –200V+1A+200mA+20mA–20V +20V +200V +1100V–20mA–100mA–1ADuty cyclelimitedModel 2410 High-Voltage SourceMeter+3A+1A+100mA–100V –60 –20+20 +60 +100V–100mA–1A–3AModel 2425 100W SourceMeter5A3ADuty cyclelimited100mA-40V 40V-10V +10V-100mA-5A1A-1A-3AModel 2440 5A SourceMeterDuty cyclelimitedDUT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!