Industrial Plugs and Sockets2.2ELECTRICAL AND MECHANICAL CHARACTERISTICSInsulating voltage:690V, 50-60Hz- minimum insulating clearance between surfaces: 10 mm- minimum clearance in air: 8 mm(for rated voltages exceeding 500 V)Operating voltage:up to 690V, 50-60HzBreaking capacity:1.25 times the rated current(test carried out at a voltage 1.1 times the ratedoperating voltage)Electrical and mechanical endurance- designed to withstand the following operations atrated voltage and current (electrical endurance) orloadless (mechanical endurance)Rated current ANo. of cyclesI <strong>Series</strong> II <strong>Series</strong> under load without load16A 20A 5.000 -32A 30A 1.000 1.000MATERIALS- Casing and insert made of engineering plastic withhigh thermal stability and mechanical strength.- Self-extinguishing to IEC 60695-2-1: casing 650 °C(glow-wire) and insert 850 °C (glow-wire).- Seal made of non-ageing EPDM elastomer or rubber.- Pins of nickel-plated brass for a perfect, lastingelectric contact.- Nickel-plated brass contact tubes with flexible springfor a constant and even contact pressure.- Nickel-plated steel terminal screws.- Contact tube springs and external screws of zincplatedsteel.- Grip and lid spring of stainless steel.- Resistance to rusting: 10 min in 10% aqueoussolution of ammonium chloride.CABLING OPERATIONSCabling capacity of the terminals:Cross-section of connectable conductors (mm 2 )RatedVoltageOver50V50Vor lessRatedcurrentPlugs, connectorsSocket outletsand appliance inletsmin max min max16A 20A 1/16 2,5/12 1,5/16 4/1232A 30A 2,5/14 6/10 2,5/14 10/863A 60A 6/10 16/6 6/10 25/4125A 100A 16/6 50/2 25/4 70/016A - 4 10 4 1032A - 4 10 4 10The terminals for pilot contacts provide connection forconductors with the same nominal cross-section as the internalterminals of 16 A plugs and connectors with rated operatingvoltage over 50 V.IEC309 AND <strong>EUREKA</strong> SERIESFAST AND EASY CABLINGSCAME’s plugs and sockets have a very special design.Their terminals are easy to get to and are already openand aligned, the cable clamp swivels and has its screwalready unscrewed, the casings are semi-screwed andthe cable glands are not completely closed. All this tohelp you save time when cabling.Plugs andsocketsAdaptorsDomesticcablereelsLampholdersTV & PhonePlates anddevices63A 60A 1.000 1.000125A 100A 250 250Impact resistance:to IEC 60309-1 section 24Galvanic anti-rusting treatment according to:UNI 3666-65General standards relating totesting corrosion of metallic materialsMax. cable size accepted by the cable clamp:EnclosuresPlugs andsocketsProtection degree:Operating temperature:IP44, IP67-25°C +80°CCertifications: most of the <strong>EUREKA</strong> <strong>Series</strong> and IEC309<strong>Series</strong> plugs and sockets are certified by IstitutoItaliano del Marchio di Qualità IMQ i and many are alsocertified by VDE, SEMKO, FI, NEMKO as shown in theindex by product number at the back of the catalogueUNI 5687-73Corrosion of metallic materialsEndurance testsCorrosion in salty mistProtection degree: when installing make sure that theseparate components, especially seals, cables and cable glands,have been fitted correctly. Any draining knock-out holes insocket outlets with IP44 should be opened and positioned inthe lower part of the casing.The protection degree of thesockets is assured either when the matching plugs are insertedor when the lids are closed; that of the plugs is assured whenthey are inserted in the matching sockets.RatedOutside ø mmcurrent min max16A 20A 8 1532A 30A 11,5 2163A 60A 7 31125A 100A 26 48When cabling, make sure that the conductors are connectedcorrectly.The pilot contact (if required) is identified by thewording “pilot”.Each terminal is identified by its symbols L1, L2,L3, N, earth; for single-phase options, L/+ and earth areindicated.Viewed from the front, the plug pins are in reverseorder to the connector tubes.InterlockedsocketsSwitchgearLight fittingsThreaded cable entryDistributionassembliesSeal(%) 10090AdaptorsStraight boxStandard SCAME flangeFixingscrews80706050403020The advantages of the <strong>EUREKA</strong><strong>Series</strong>. The technical solutionsoffered by the Eureka series cutdown on cabling time, whichmeans a saving in labour costs.The chart shows the amount oftime saved with the <strong>EUREKA</strong> <strong>Series</strong>compared to the IEC309 <strong>Series</strong>.Industrialcable reelsAccessoriesWire connectors1002P+T 2P+E 3P+E 3P+T 3P+N+T 3P+N+EConduitsIEC309 <strong>Series</strong><strong>EUREKA</strong> <strong>Series</strong>TrunkingSurface mounting socketoutlets - straight boxCabling time in relative terms,Taking the IEC309 <strong>Series</strong> 3P+N+E plug or connector cabling time as equal to 100%.Index170171

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!