13.07.2015 Views

302IC4.6™ Ion-Chromatography Column - Western Analytical

302IC4.6™ Ion-Chromatography Column - Western Analytical

302IC4.6™ Ion-Chromatography Column - Western Analytical

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Environmental and Food Analysis: 201TP and202TP Specialty Reversed-Phase <strong>Column</strong>sPolyaromatic hydrocarbons (PAHs) are large organicmolecules produced during combustion. Many PAHsare carcinogenic. For this reason the United StatesEnvironmental Protection Agency (EPA) and othergovernmental agencies have formulated regulationsfor the monitoring and control of PAHs and havedeveloped methods for their measurement in air,water, food, and other components of the humanenvironment.The EPA has designated sixteen PAHs as PriorityPollutants (see Figure on page 54). EPA Methods 610and 550 deal with the measurement of PAHs indrinking water and Method 8310 deals with themeasurement of PAHs in waste water. These EPAmethods specify reverse phase High PerformanceLiquid <strong>Chromatography</strong> (HPLC) for measurement ofthe PAHs.Vydac 201TP HPLC columns have long been thestandard in the analysis of PAHs by HPLC. Vydac201TP and 202TP HPLC columns have been specificallydeveloped to perform the separation and quantitationof PAHs required by environmental regulations – notonly regulations presently in force but also newregulations on the horizon.Vydac 201TP columns have been used to establishstandard reference materials (Ref. 1, 5*), measure airquality (Ref. 1-4*), measure PAHs in sediments(Ref. 6*), quantitate PAHs in food (Ref. 7-8*), andstudy high molecular weight PAHs (Ref. 9*). Theyhave also been used in the study of shape selectivityof reversed phase materials.* References on page 56.Ordering InformationCat.No.Description201TP54 Specialty Reversed-Phase <strong>Column</strong>, C 18,5 µm, 300 Å, 4.6 mm i.d. x 250 mm201TP5415 Specialty Reversed-Phase <strong>Column</strong>, C 18,5 µm, 300 Å, 4.6 mm i.d. x 150 mm202TP54 High-Carbon-Load Reversed-Phase <strong>Column</strong>,C 18, 5 µm, 300 Å, 4.6 mm i.d. x 250 mm202TP5415 High-Carbon-Load Reversed-Phase <strong>Column</strong>,C 18, 5 µm, 300 Å, 4.6 mm i.d. x 150 mmRapid-Analysis <strong>Column</strong>:202TP3405 High-Carbon-Load Reversed-Phase <strong>Column</strong>,C 18, 3 µm, 300 Å, 4.6 mm i.d. D x 50 mmFeatured products are:❏ 201TP54 and 201TP5415 columns – thestandard for PAH analysis in all types of environmentalsamples. Vydac 201TP columns separatethe EPA sixteen priority pollutants in less thantwenty minutes (see top figure on page 54).❏ 202TP3405 Rapid-Analysis columns newlydeveloped to separate the 16 Priority PollutantPAHs in under 10 minutes (see bottom figure onpage 54).❏ 202TP54 and 202TP5415 columns for theanalysis of derivatized PAHs.Beyond the 16 EPA priority pollutant PAHs, VydacPAH columns are used to separate many other PAHs,such as methylated naphthalenes (see figure on page 55and Ref. 9 on page 56).Vydac 201TP HPLC columns have longbeen the standard for the analysis ofPAHs in:• Water• Air• Soil• Automotive Exhaust• Food“201TP” and “202TP” are trademarks of The Separations Group, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!