13.07.2015 Views

nanoRaider - FLIR.com

nanoRaider - FLIR.com

nanoRaider - FLIR.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ONE TOUCH REACHBACKLike other <strong>FLIR</strong> radiation instruments, the <strong>nanoRaider</strong> enables themost advanced <strong>com</strong>munications features available in any classof radiation detector. With One Touch Reachback, users canimmediately provide full spectroscopic data as well as detaileddevice information, time, and GPS location to as many people asnecessary with the push of a button.WEB INTERFACENo longer do users have to physically connect their device toa <strong>com</strong>puter, install secondary software, or use external emailto provide alarm notifications. Through a simple Bluetooth®connection, such notifications are all but automatic. This uniquecapability provides added security by retaining all detection andidentification data on the instrument itself and not on a local<strong>com</strong>puter.NEXT GENERATION CZTCadmium Zinc Telluride (CZT) detectors are known for betterresolution in a smaller detector without the need for temperaturestabilization. Through ongoing research and development, <strong>FLIR</strong>has optimized this material for radiation detection and accuratesource identification. In the <strong>nanoRaider</strong>, this ability virtuallyeliminates the inconvenience and expense associated with falsealarms and false positives, not to mention the time involved inobtaining secondary inspections necessary to clear an alarm. Inaddition, the CZT material is naturally more rugged than typicalscintillation detectors and is able to survive the general abusetypical of field deployments.FEATURES• Transflective color display• 24 hour battery life• IP63 <strong>com</strong>pliant enclosure protection• Data storage for up to 600,000 identificationsand spectra and over 1 million alarms• ANSI N42.48 <strong>com</strong>pliant• Standard ANSI N42.42 data output formatas preferred by triage teams as well as thegovernment and scientific <strong>com</strong>munitiesA FAMILY OF INSTRUMENTSUnlike other <strong>com</strong>panies, <strong>FLIR</strong> takes the approach that one sizedoesn’t fit all. We understand how important it is to have aninstrument that meets the specific requirements of the mission athand. To that end, the <strong>nanoRaider</strong> provides the same high qualityresults as much larger instruments, but with an inconspicuous,<strong>com</strong>pact design.The entire family of <strong>FLIR</strong> radiation instruments has been developedto address the specific sensitivity, resolution, size, and weightrequirements of a variety of applications. Furthermore, each ofthese instruments, including the <strong>nanoRaider</strong>, employs the samesimple to use and understand interface, which in turn reduces thetraining burden. With more than 14,000 radiation instrumentsdeployed worldwide, the well-known and trusted <strong>FLIR</strong> userinterface has be<strong>com</strong>e industry standard.The Americas2800 Crystal DriveSuite 330Arlington, VA 22202T +1.703.416.6666Middle EastSuite 1-11Building 6E-ADubai Airport FreezonePO Box 371363Dubai, UAET +971 4 701 7195F +971 4 701 7194EuropePiepersberg 1242653 SolingenGermanyT +49 212 222090F +49 212 201045AsiaLevel 28 Gateway East152 Beach RoadSingaporeT +65.6827.9789F +65.6295.2567nanoraider_092311www.flir.<strong>com</strong>/detection

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!