13.07.2015 Views

Thermostatic valve bodies with presetting Series ... - Watts Industries

Thermostatic valve bodies with presetting Series ... - Watts Industries

Thermostatic valve bodies with presetting Series ... - Watts Industries

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2THERMOSTATIC VALVE BODIESOperationValve operation is by manual movement (through the protective cap) or automatic movement (combined <strong>with</strong>thermostatic or electrothermic actuators) of the plug which shuts off the heat carrier fluid. The hydraulic flow rateand pressure drop characteristics for the <strong>valve</strong>s can be deduced from appropriate charts: in the thermostaticfunction they assume the characteristics of such device. The reliability of the thermostatic <strong>valve</strong> <strong>bodies</strong><strong>Series</strong> 130UM, 131UM, 1130UM, 1131UM, is guaranteed by the 100% testing of the production which testsfor water tightness of the <strong>valve</strong> body and its components towards the outside and the tight seal of the plug in itsflow shut-off function.Pre-setting1- Pull out the handwheel by turningit anti-clockwise (Pic.1)2- fully close the <strong>presetting</strong> ring nut (Pic.2)3- Open the ring nut until the requiredposition by making the number to coincide<strong>with</strong> the reference notch (Pic.3)1435Pic. 17654Pic. 2321454Pic. 33Dn3/8"1/2"3/4"3/8"1/2"3/4"±%Where :Installation1 280 17580 17580 18075 16075 17580 18060 30qmsKv =316321521523020022524020Pre-settingQms (l/h)4 521521523020022524010Valve selection is based on the size of the connection to the radiator and the connecting piping. <strong>Thermostatic</strong><strong>valve</strong> <strong>bodies</strong> <strong>Series</strong> 130UM, 131UM, 1130UM, 1131UM can be installed on radiators supplied by iron, copperand plastic pipes, coupled <strong>with</strong> the balancing lockshield <strong>valve</strong>s of <strong>Series</strong> 195UM, 196UM, 1195UM, 1196UM.When the system requires thermostatting, merely remove the protective cap from the cap and replace it <strong>with</strong> athermostatic or electrothermic actuators by tightening the ring nut. All this can be done <strong>with</strong>out plumbing work and<strong>with</strong> the system running.21521523020022524010621521523020022524010721521523020022524010Max21521523020022524010Qmn21521523020022524010Hydraulic characteristicsSettingpositions1234567A130UM 3/8"1130UM 3/8"0.270.600.881.121.311.461.602.05Kv values in the various pre-setting positions130UM 1/2"1130UM 1/2"0.270.620.901.131.321.471.602.60130UM 3/4"0.270.671.001.301.561.802.003.30131UM 3/8"1131UM 3/8"0.270.570.780.910.971.001.021.10131UM 1/2"1131UM 1/2"0.270.640.901.121.301.441.551.80131UM 3/4"0.270.640.951.231.511.741.962.602413Features1) Presetting stuffing nut can be replaced also <strong>with</strong> the system under pressure.2) Complete plug can be replaced <strong>with</strong>out emptying the system by using Art. 225.3) O-ring sealed tailpiece.4) Plug seal of elastomeric material, vulcanized ethylene-propylene terpolymer (EDPM).Technical characteristicsNominal pressureMax. differential pressureMax. temperatureUsable liquidsDesign featuresValve bodyHandwheelO-ringTailpiece10 bar1.5 bar110° CWater also <strong>with</strong>glycol ≤ 50%Brass CW617NPolypropyleneEPDMBrass CW617N

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!