<strong>Saint</strong> –<strong>Gobain</strong> Deutsche Glas – KINON Porz Sicherheitsglas GmbH 11.01.2005 13:26<br />
Applications:<br />
Glazings with <strong>SGG</strong> STADIP <strong>PROTECT</strong> are suitable, depending upon resistance class, for numerous safetysensitive<br />
areas:<br />
IMPACT RESISTANT glass (CLASS P-A): Glazings of windows and french windows to the failure protection<br />
within the private living area.<br />
MANUEL ATTACK RESISTANT (CLASS P-B): Glazings of windows, shop windows and doors against failure at<br />
private and firms and against outbreak from psychiatric hospitals and penal institutions, also as glazings of animal<br />
cages and aquariums.<br />
BULLET RESISTANT (CLASS BR): Glazings of banks, military systems and other administrative and firms as<br />
well as protection of individuals.<br />
BLAST RESISTANT (CLASS D): Glazing of public buildings such as airports, military systems and embassys.<br />
Range:<br />
<strong>SGG</strong> <strong>STADIP®</strong> <strong>PROTECT</strong> P-A Impact-resistant in accordance with DIN EN 356 A<br />
A continuous increase in the number of burglaries and more and more damage caused by vandalism necessitate<br />
greater saftey and security in private and public areas.<br />
DIN EN 356 A determines the test conditions for impact resistant glazing. The requirement with respect to<br />
resistance to impacts is devided into five resistance categories. The division into categories is determined by the<br />
striking energy of heavy missiles. The resistance categories ranges of application can be assigned.<br />
The testing method is a ball drop test. Each pane must withstand three impacts of a steel ball weighing about 4 kg.<br />
The drop heights for the individual categories are as follows:<br />
Category P1A = 1.5 m Category P3A = 6.0 m Category P5A = 9.0 m *)<br />
Category P2A = 3.0 m Category P4A = 9.0 m *) with nine impacts of a 4 kg steel ball.<br />
<strong>SGG</strong> <strong>STADIP®</strong> <strong>PROTECT</strong> P-A<br />
Impact Resistant in<br />
accordance with DIN EN 356 A / DH 4*<br />
Examples of application Certificate<br />
Project area Private houses Resistance<br />
category<br />
Type of<br />
glazing<br />
Type Thickness<br />
mm<br />
Weight (kg/m²) No.<br />
lowest saftey level P1A EN Mono 107 7 16 DW 99 003<br />
against vandalism P1A EN Iso CP 107 21 (1)<br />
second floor<br />
first floor<br />
Ground floor<br />
residential<br />
housing,<br />
condominimum<br />
and housing<br />
estates<br />
remotely-located<br />
houses<br />
high security in<br />
private, holiday<br />
and weekend -<br />
homes<br />
exclusive<br />
houses<br />
26 DW 99 003<br />
P2A EN Mono 209 9 21 DW 99 004<br />
P2 EN Iso CP 209 23 (1)<br />
31 DW 99 004<br />
P3A EN Mono 309 9 21,5 DW 99 004<br />
P3A EN Iso CP 309 23 (1)<br />
31,5 DW 99 004<br />
P4A EN Mono 410 9,5 22 DW 99 008<br />
P4 EN Iso CP 410 24 (1)<br />
32 DW 99 008<br />
P5A EN Mono SP 510 10 23 DW 99 002<br />
P5A EN Iso CP-SP 510 24 (1)<br />
VdS higher risks DH4 VdS Mono DH 4.15 11 23<br />
DH4 VdS Iso DH 4.25 24,5 (1)<br />
33 DW 99 002<br />
(1) DGU with 10 mm spacer: U-value = 1,8 W/m 2 K with <strong>SGG</strong> PLANITHERM or 1,6 W/m²K with <strong>SGG</strong> PLANITHERM FUTUR<br />
double glazing ouside pane 4 mm; thicker panes possible for static reasons<br />