03.12.2012 Views

Technical information for cylindrical curved glass

Technical information for cylindrical curved glass

Technical information for cylindrical curved glass

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Min. radius<br />

Max. angle<br />

Max. dimensions<br />

Min. dimensions<br />

Max. pitch<br />

Max. weight<br />

Dimensional<br />

tolerances<br />

<strong>Technical</strong><br />

feasibility<br />

Site 1/2<br />

<strong>Technical</strong> <strong>in<strong>for</strong>mation</strong><br />

<strong>for</strong> <strong>cylindrical</strong> <strong>curved</strong> <strong>glass</strong><br />

Cylindrical <strong>curved</strong> float <strong>glass</strong><br />

50 mm (shop counters)/100 mm (architectural <strong>glass</strong>)<br />

180°<br />

girth x height / width<br />

5.850 x 2.750 mm *, or 2.750 x 5.850 mm *<br />

4.100 x 3.745 mm *, or 3.750 x 4.100 mm *<br />

800 mm<br />

1000 kg/each panel<br />

Cylindrical <strong>curved</strong> insulating <strong>glass</strong><br />

100 mm (shop counters)/200 mm (architectural <strong>glass</strong>)<br />

150° (180° up to 400 mm height)<br />

see float <strong>glass</strong><br />

* The table shows the max. theoretically possible dimensions. Sizes can vary depending on used <strong>glass</strong> (thickness/function) and shape.<br />

on request<br />

on request<br />

800 mm<br />

1000 kg/each panel<br />

Glass thickness 2–19 mm<br />

maximum <strong>glass</strong> thickness on request<br />

Bendable <strong>glass</strong><br />

types<br />

• Low-iron extra-clear <strong>glass</strong>, e.g. Diamant (Saint-Gobain),<br />

Optiwhite (Pilkington)<br />

• Tinted float <strong>glass</strong> (e.g. Parsol)<br />

• Anti-reflective <strong>glass</strong> e.g. Amiran®, Conturan® (Schott AG)<br />

• Mirror with chrome coating MIRASTAR® (Saint-Gobain)*<br />

• Self-cleaning <strong>glass</strong>: Bioclean® (Saint-Gobain)<br />

• Cast <strong>glass</strong> and rolled <strong>glass</strong> (with some limitations)<br />

• Antique sheet <strong>glass</strong><br />

• Wired <strong>glass</strong><br />

• Screen printed <strong>glass</strong> (screen print on the inside)<br />

• Decoration <strong>glass</strong><br />

• Frosted <strong>glass</strong><br />

• Mattfinished <strong>glass</strong> (partial or completely)<br />

• Etched and sandblasted <strong>glass</strong>, also with CLEAR-SHIELD®<br />

• Bevelled <strong>glass</strong><br />

• Enamelled float <strong>glass</strong><br />

• Shatter-resistant with security window films<br />

• Partial or complete coverage with coloured <strong>glass</strong><br />

painting. Powder coating is also available.<br />

*Notice: The values listed under <strong>Technical</strong> Data are only <strong>for</strong> guidance. The geometrical parameters of a <strong>curved</strong> <strong>glass</strong> pane, the min./max.<br />

values of the parameters as well as the requested <strong>glass</strong> assembly are closely linked and influence the corresponding limiting values of each<br />

other. Limits of size, dimensions, possible <strong>glass</strong> thickness and bending angles are determined according to individual arrangement and<br />

thorough technical examination. Restrictions in the <strong>for</strong>m of shape must be expected.<br />

Remark: technical modifications and errors<br />

excepted!<br />

see float <strong>glass</strong><br />

The following <strong>glass</strong> types can be used <strong>for</strong> the production<br />

of <strong>curved</strong> double glazed units:<br />

• Solar control <strong>glass</strong> with hard coatings, e.g. ANTELIO,<br />

COOL-LITE ST 150, STOPSOL, Sunergy, Silverstar<br />

Sunstop T or with combined solar and thermal control<br />

coatings e.g. COOL-LITE ST 167*, Sun-Guard Solar®,<br />

Sun-Guard® HP *<br />

• Heat protection <strong>glass</strong><br />

Planitherm Ultra N II (soft coating),<br />

K-Glass (hard coating)<br />

• Acoustic protection <strong>glass</strong> compositions with "Stadip<br />

Silence" (sound insulation interlayer) are also available<br />

• Safety termal insulating <strong>glass</strong> in connection with<br />

heat protection, acoustic protection, sun protection<br />

and special laminated safety <strong>glass</strong> combinations with<br />

different resistance class according to DIN EN 356<br />

For all <strong>curved</strong> <strong>glass</strong> products manufactured in our company, the general tolerance and conditions in accordance to "Guideline<br />

<strong>for</strong> thermal bend architectural <strong>glass</strong> products ", BF-datasheet 009/2011 from Bundesverband Flachglas e.V. and the "Guideline<br />

to Assess the Visible Quality of Glass in Buildings." are valid (unless otherwise agreed in writing).<br />

• Cavity width range: preferably 6 - 14 mm, max. 20 mm<br />

• Insulating <strong>glass</strong> gas filling: Argon, Krypton<br />

• Production with Super Spacer® TriSeal<br />

• Warm-edge-technology, thereby excellence features<br />

in thermal isolation<br />

• Glass compositions are depending on geometry<br />

• Special insulating <strong>glass</strong> <strong>for</strong> stepped-units with UVresistant<br />

edge seal<br />

• The closer radius, smaller dimensions, the higher load<br />

on the edge seal because bending stiffness (less<br />

pumpable)<br />

• Per<strong>for</strong>mance data of <strong>glass</strong> compositions (light transmission,<br />

light reflection, energy transmission, energy reflection,<br />

UV-transmission and g-value) can only be mentioned<br />

according to values of comparable planar <strong>glass</strong><br />

compositions (calculation with CALUMEN software)<br />

At the moment we are able to achieve a Ug-Value up to 1,1 W/m 2 K <strong>for</strong> double-glazed units in accordance with<br />

DIN EN 673. With an <strong>curved</strong> triple-glazed unit, even a Ug-value up to 0,5 W/m 2 K in accordance with DIN EN 673 is<br />

possible. We produce insulating <strong>glass</strong> units in accordance with EN 1279. For more <strong>in<strong>for</strong>mation</strong> of marking<br />

products please contact us.


Min. radius<br />

Max. angle<br />

Max. dimensions<br />

Min. dimensions<br />

Max. pitch<br />

Max. weight<br />

Glass thickness<br />

Bendable <strong>glass</strong><br />

types<br />

Dimensional<br />

tolerances<br />

<strong>Technical</strong><br />

feasibility<br />

Site 2/2<br />

<strong>Technical</strong> <strong>in<strong>for</strong>mation</strong><br />

<strong>for</strong> <strong>cylindrical</strong> <strong>curved</strong> <strong>glass</strong><br />

Cylindrical <strong>curved</strong> laminated <strong>glass</strong><br />

Cylindrical <strong>curved</strong><br />

toughened <strong>glass</strong>/heat-strengthened <strong>glass</strong><br />

100 mm 400–800 mm Depending on thickness, size, shape and<br />

function (coating etc.)<br />

150°<br />

girth x height/width<br />

3.000 x 5.000 mm *, or<br />

5.000 x 3.000 mm<br />

more on request<br />

* The table shows the max. theoretically possible dimensions. The sizes can vary depending on used <strong>glass</strong> (thickness<br />

and function) and the shape.<br />

on request<br />

800 mm<br />

1000 kg/each panel<br />

For our standard laminated <strong>glass</strong> as safety <strong>glass</strong>, we use<br />

clear foil with a thickness of 0.76 mm. Also multiple<br />

layers of Polyvinylbutyral (PVB)-foil and <strong>glass</strong> are available.<br />

On request, we can also process coloured laminated<br />

safety <strong>glass</strong>.<br />

width x length<br />

2.400 x 4.000 mm *<br />

400 x 500 mm<br />

400 mm<br />

1000 kg/each panel<br />

4–34 mm Toughened <strong>glass</strong> 5-15 mm<br />

Heat-Strengthened <strong>glass</strong> 4-10 mm ( under construction)<br />

see float <strong>glass</strong><br />

Resistance class approved safety features GLABIE<br />

laminated <strong>glass</strong> (related to planar superstructures<br />

PVB-AF-Trosifol)<br />

• impact-resistance (P1A–P5A)**<br />

• manuel attack-resistance (P6B–P8B)**<br />

• bullet resistance (BR1S–BR4S)**<br />

• explosion resistance<br />

• laminated <strong>glass</strong> with built in alarm-wire<br />

• coloured laminated <strong>glass</strong> is also available<br />

** in reference to safety glazing standard DIN EN 356<br />

Laminated <strong>glass</strong> with SI foil achieve good sound<br />

insulation�per<strong>for</strong>mance data, even as monolithic<br />

composition e.g. laminated <strong>glass</strong> 44.2 = 37 dB<br />

With laminated <strong>glass</strong> and 0,76 mm PVB foil edge shift be<br />

expected max. 1,5 mm/meter edge (max. 5 mm)<br />

• Clear- and tinted float <strong>glass</strong> (Parsol)<br />

• Low-iron extra-clear <strong>glass</strong><br />

• Anti-reflective <strong>glass</strong><br />

• Satined <strong>glass</strong><br />

• Patterned <strong>glass</strong><br />

• Screen-printed and enamelled <strong>glass</strong><br />

(print only on concave side)<br />

• Solar- and thermal control <strong>glass</strong> (hard coating/<br />

soft coating/combination of coatings)<br />

Please contact us <strong>for</strong> your request.<br />

*Notice: The values listed under <strong>Technical</strong> Data are only <strong>for</strong> guidance. The geometrical parameters of a <strong>curved</strong> <strong>glass</strong> pane, the min./max.<br />

values of the parameters as well as the requested <strong>glass</strong> assembly are closely linked and influence the corresponding limiting values of each<br />

other. Limits of size, dimensions, possible <strong>glass</strong> thickness and bending angles are determined according to individual arrangement and<br />

thorough technical examination. Restrictions in the <strong>for</strong>m of shape must be expected.<br />

For all <strong>curved</strong> <strong>glass</strong> products manufactured in our company, the general tolerance and conditions in accordance to "Guideline<br />

<strong>for</strong> thermal bend architectural <strong>glass</strong> products ", BF-datasheet 009/2011 from Bundesverband Flachglas e.V. and the "Guideline<br />

to Assess the Visible Quality of Glass in Buildings." are valid (unless otherwise agreed in writing).<br />

90°<br />

• Heat-soak tested fully tempered (toughened)<br />

safety <strong>glass</strong><br />

• Fire resistant <strong>glass</strong> (in cooperation)<br />

• Alarm Securit®<br />

• Thermovit – heatable <strong>glass</strong><br />

It's possible to manufacture <strong>curved</strong> tempered <strong>glass</strong>,<br />

<strong>curved</strong> tempered <strong>glass</strong> with heat-soak test and <strong>curved</strong><br />

heat-strengthened <strong>glass</strong> into laminated safety <strong>glass</strong><br />

and insulated <strong>glass</strong> to meet every safety and security<br />

specification.<br />

05.2012 • Remark: technical modifications and errors excepted!