#003 and #004 Receiving Unit Wiring Instructions:With fan suspended from ceiling and with power off at breaker box, make wireconnections as shown below. The receiving unit sits in the ball hanging bracketof most models as pictured (a), or in the upper portion of the fan body inHugger fans, Stratos and Eclipse models (b)and (c).WHITEBLACK or REDBLUETo NeutralTo <strong>Fan</strong> MotorTo LightDip SwitchesAntennaWHITEBLACKA/C Power In (Neutral)A/C Power In (Load)Receiving Unit Placement:While there is ample room for the receiving unit as shown here, the wires cansometimes become difficult to manage in the space available. Trimming excesswire before making connections can ease wire management.Tip: Splicing lighter gauge wire to the power supply and positioning the heavierwires up into the junction box can also ease wire management.(a)(a)(b)(c)Reminder:Any fan that uses a fluorescent lamp may not be dimmed or operated with adimming control. Non-dimming versions of our controls are available for usewith the Aurora, Aurora Hugger, or any other model using a fluorescent lamp.Non dimming controls are designated by the suffix “ND”.