Technical Specification for A.C. Single Phase, 2 Wire ... - WBSEDCL

Technical Specification for A.C. Single Phase, 2 Wire ... - WBSEDCL

Technical Specification for A.C. Single Phase, 2 Wire ... - WBSEDCL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Physical examination of the meters.Non-registration with Voltage along at 70% V ref and at 120% V ref.Starting current at 0.2% I basic UpfHigh voltage test.Insulation resistance test.Test of protection <strong>for</strong> withstanding 433 volt between phase & neutral <strong>for</strong> a period of atleast 4 hours without any load.Test of endurance up to 150% I maxDuring the above tests, if no of meter fails is less than or equal to 1 no., the lot shall beconsidered to be con<strong>for</strong>ming to the above tests. If no. of meter fails is greater than 1 no. butless than 4 (four), further re-sampling will be done and the numbers of re-sampled metersshall be 32, selected at random from the said Lot of 20,000 nos.The re-sampled meter will again be subjected to the tests as mentioned above and if numberof meters in two samples (combined) 64 (sixty four) nos. is less than 4 (four) nos., the lot shallbe considered to be con<strong>for</strong>ming to the above tests otherwise rejected.Further testing <strong>for</strong> 8 nos. meters selected from 32 nos. sample meters will be carriedas follows :Limits of error on all the sample meters at :1% I basic 1.0 pf. (±2% is preferable but should not exceed ±3%)2% I basic 1.0 pf.5% I basic 1.0 pf., 0.5 pf. Lag & 0.8 lead10% I basic 1.0 pf., 0.5 pf. Lag & 0.8 lead50% I basic 1.0 pf., 0.5 pf. Lag & 0.8 lead100% I basic 1.0 pf., 0.5 pf. Lag & 0.8 lead200% I basic 1.0 pf., 0.5 pf. Lag600% I basic 1.0 pf., 0.5 pf. LagTest of meter constant and meter dial <strong>for</strong> one unit at 200% I basic, 0.866 pf.Lag.Power loss on voltage & current circuit.Further testing <strong>for</strong> 3 Nos. sample meters will be carried as follows:Repeatability of error test at 5% I basic Upf & 100% I basic Upf.The maximum divergent should be less than 0.5%.If anyone of the meter fails on any of the above tests, the lot will be rejected.Further testing <strong>for</strong> 1 No. sample meter will be carried as follows:Magnetic induction of external origin (AC & DC).Electro Static Spark Discharge of 35KVpTamper and Fraud protection as per Clause 12 ( I to vii) (Anti-tamper feature)of our specification.Injection of DC pulse (low frequency) in the neutral.Dry –heat test as per clause 12.6.1 of IS: 13779/99.At least one sample selected from any lot of the meters offered <strong>for</strong> inspection will besealed by us and handed over to the supplier <strong>for</strong> testing at NABL accreditedlaboratory. Presence of purchaser‟s representative during dry heat test at NABLaccredited laboratory is not required. But in the test report meter Sl. No. & meterbody seal nos. is to be mentioned.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!